Home

ILUMICON - Iluminarc

image

Contents

1. Power and Wiring 0cccccceeeecceeececceeeeecceueeeceucecceueeecseeeecseeeeseuseeeseeeessadeeessageeessueeessnseesans 2 KEE 2 2 Product Description 22222222 cs EU DEDE EDER SEERNES 3 FOUG wasctevans ananeeqncdannce ner suanqeutonaanesantieanseistap asad onanoaataneegucdnsaee T 3 Bee fie 4 Product DIMENSIONS EE 5 3 MPVS Cz AU Fre 7 p PONOR UO ROOM EN SERENE OR E NR 6 AC e E WEE 6 Power CongumplhiON essercene iea E A EE ea EEE EeP ETES ER oa 6 DMA CIK Le E 7 DMX COMMECICH TE 7 Jee AMON ING EE 8 Se EET O ac reeacee 8 POGUE LIKING EE 9 BERG ell e E E E E EE E E 9 MOUN e DE 10 JE e e EE 10 0161 19 V MMO MY MPR NO P EET E A A EE 10 FO o o REE E E E re 11 CORTON Panel Des ED NON EE 11 SU O E 11 MII IVIAD EE 12 WV AS E elen RT O E 13 ERE Ir FOCI SUNN EE 13 IS OMI PO CIENT EE 13 SEVEN 13 elei SE SEE ES eee nee eee ee eee 13 Oe ecu bah sted SET O O O 13 EE 14 Activating Password Mode E 14 Control via External DMX scicccdcncinsuotseantedacechauaeiacudedidetadussinashetasdannnesdennadeedasantededeebdncean 14 DMX Channel KE UE 15 5 Technical Information c roreeeeoeee eno e REN EEN REN R ENKEN nnmnnn 16 Product Mallenahc EEG EET 16 Belle de 16 Troubleshooting Gude EE 16 Returns Procedure euromince 17 OAC D 17 Technical Specifications sinan eaa EEE Ene aa Kaa Ra Ke Kon 18 ILUMICON User Manual Rev 02 i J Introduction 1 Introduction This icon indicates critical installa
2. 10 products on ID addressing per DMX channel This is to remain within a one second execution time em led Operation Control Panel Description Button Function Accesses main menu or exits from the current menu or function Enables the currently displayed menu or sets the i currently selected value in to the current function Navigates upwards through the menu list and increases the numeric value when in a function OO O O Ce Navigates downwards through the menu list and E EE EE lt MODE gt lt SETUP gt lt UP gt lt DOWN gt decreases the numeric value when in a function Setup 1 Connect from the OUT on the controller to the DMX Input side of the ILUMICON using a DMX XLR cable 2 It is recommended that you power up all products connected prior to turning on the controller This ensures that the controller will auto detect all DMX addresses Alternatively you can use Detect device from the Settings menu 3 Set ID addresses on the units in ascending order 4 Set the Range in the Settings menu 5 Note There is no need to set ID and Range for Wash programs J L Power m Ta other fixtures ILUMICON Controller ILUMICON User Manual Rev 02 1 Operation Menu Map Main Function Selection Selection Selection Selection Wash 1 Step time Defines the duration of each i 001 255 program step MARN Program Wash 8 ER Fade time Defi
3. If using A4 paper 210 x 297 mm configure your printer to scale the content of this document to A4 paper Intended Audience Any person in charge of installing operating and or maintaining the ILUMICON should read all of this User Manual before installing operating or maintaining this product Disclaimer ILUMINARC believes that the information contained in this manual is accurate in all respects However ILUMINARC assumes no responsibility for any error or omissions in this document ILUMINARC reserves the right to revise this document and to make changes from time to time in the content hereof without obligation of ILUMINARC to notify any person or company of such revision or changes This does not constitute in any way a commitment by ILUMINARC to make such changes ILUMINARC may issue a revision of this manual or a new edition of it to incorporate such changes Document Revision The ILUMICON User Manual Rev 02 supersedes all previous versions of this manual Please discard any older versions of this manual you may have whether in printed or electronic format and replace them with this version Author Date Editor Date S Graham 01 09 12 01 09 12 ILUMICON User Manual Rev 02 Table of Contents 1 Introduction EE 1 What leinlbebos eee k kt kb E RE ERE RE ERE ee eee KK REEL EL PKR KK KK KK OKR KKK OKR K nK n 1 Unpacking ll RUS oj a PPP 1 VERO O O O 1 Eet 1 Eege 2 Wiele 2 Mounting and Installation EE 2
4. affixed Me EE if the to the side of the product Alternatively you may refer to the corresponding channel serves only as a specifications chart in the Technical Information chapter of this manual 0 to 100 switch The listed current rating indicates the maximum current draw during normal operation 6 ILUMICON User Manual Rev 02 hy DI AD i Installation ILUM DMX Linking If using the ILUMICON Controller along with other DMX compatible fixtures it is possible to control them individually with a single DMX controller DMX compatible fixtures use a serial data link between them If you are not familiar with the DMX standard or if you need information about the DMX cables needed to link the ILUMICON to a DMX controller you may download the DMX Primer from the ILUMINARC website at http www iluminarc com reports dmx primer DMX Connection The ILUMICON uses the standard DMX data connection for its 4 channel DMX mode Refer to the Introduction chapter for a brief description of this mode and the Operation Instructions chapter to learn how to configure the ILUMICON to work in this mode The DMX Channel Values section will give you detailed information regarding the 4 channel DMX mode The procedure below illustrates a possible connection method 1 Connect the 3 pin male connector of the first DMX cable to the DMX Output connector 3 pin female of the DMX controller 2 Connect the 3 pin female connector of the
5. box and all packaging material as you will need those to ship the product back to ILUMINARC F Ka ia i i k E g KR i W i Bi MAr LA Returns Procedure You must send the merchandise prepaid in the original box and with its original packing and accessories ILUMINARC will not issue call tags Call ILUMINARC and request a Return Merchandise Authorization Number RMA before shipping the product Be prepared to provide the model number serial number and a brief description of the cause for the return The user must clearly label the package with an RMA ILUMINARC will refuse any product returned without an RMA DO NOT write the RMA directly on the box Instead write it on a properly affixed label Once you receive the RMA please include the following information on a piece of paper inside the box e Your name e Your address e Your phone number e The RMA ff e A brief description of the problem Be sure to pack the product properly Any shipping damage resulting from inadequate packaging will be the customer s responsibility As a suggestion proper FedEx packing or double boxing are the shipping methods ILUMINARC recommends Contact Us World Wide General Information ILUMINARC 5200 NW 108th Avenue Sunrise FL 33351 Voice 954 923 3680 Fax 954 929 5571 Email info iluminarc com Customer Support Voice 954 923 3680 ext 4000 Fax 954 756 8015 Email tec
6. least twice a month Dust build up reduces performance and can cause overheating To clean a product D edn Wl S e Unplug the product from power carefully after e Wait until the product has cooled cleaning them i e Use a vacuum or dry compressed air and a soft brush to remove dust collected on the external vents and reachable internal components e Clean all plastic surfaces with mild soapy water and a soft lint free cotton cloth or a lens cleaning tissue Product Repairs ILUMINARC strongly advises you against attempting any repairs to this product unless you are an authorized ILUMINARC technician ILUMINARC presents the information contained in the Troubleshooting Guide as potential solutions only In most cases opening the product s housing will invalidate its warranty unless there is a written indication to the contrary Troubleshooting Guide Symptom Action s de gr Ee Use only DMX compatible cables E problems after Loss of signal Install terminator as suggested in the DMX trying the Primer on the Iluminarc website Troubleshooting Guide Chase is too slow Check speed adjustment contact ILUMINARC Check for power on mains Technical Support Device has no power Check I O ports on adapter 16 ILUMICON User Manual Rev 02 D ul Fj d ILUMINARC reserves the right to use its own discretion to repair or replace returned product s i Always keep the original
7. 6 etc MENU 2 Settings ID address D 01 66 It is not necessary to set the DMX address Controller Setup When using the Effect program function it is necessary to set the Settings Range setting which is the quantity of products in series MENU 2 Settings 2 Range No of fixtures S i n g le Ro W ID Address 01 ID Address 02 ID Address 03 ID Address 04 ID Address 05 ID Address 06 Application The product above shows 6 products connected in series with corresponding addresses Each product has ID ON in the products settings You must set the Range settings in the controller to 006 before accessina Effect proarams GO O O Oe Repeat Row Block Application Block Application i dh ID Address gt z e s i ID Address Ta The figure above shows 9 products The figure above shows 9 fixtures connected in series Three rows connected in series with comprised of 3 products are addressed a 9 corresponding addresses Each identically Each product has ID ON in fixture has ID ON in the fixture s i the product s settings You must set the o i settings You must set the Range settings in the controller to 003 0900 00 Range settings in the controller oo O O06 before accessing Effect programs to 009 before accessing Effect aia programs ILUMICON User Manual Rev 02 ILUMINARG Prod
8. ILUMICON User Manual LUMINARC Edition Notes Edition Notes The ILUMICON User Manual Rev 02 covers the description safety precautions installation programming operation and maintenance of the ILUMICON controller ILUMINARC released this edition of the ILUMICON User Manual Rev 02 in January 2012 Trademarks The ILUMINARC logo the ILUMINARC name and all other trademarks in this document related to services or products by ILUMINARC are trademarks owned or licensed by ILUMINARC its affiliates or subsidiaries Any other product names logos brands company names trademarks featured or referred to within this document are the property of their respective trademark holders Copyright Notice The entire content of this document except where applicable and unless otherwise noted is solely owned by ILUMINARC a wholly owned trademark of CHAUVET amp Sons Inc Copyright 2012 ILUMINARC All rights reserved Electronically published by ILUMINARC in the United States of America Manual Usage ILUMINARC authorizes its customers to download and print this manual for professional information purposes only ILUMINARC expressly prohibits the usage copy storage distribution modification or printing of this manual or its content for any other purpose without its written consent Document Printing For better results print this document in color on letter size paper 8 5 x 11 in double sided
9. N keys Press the SET button to confirm Control via External DMX Programs in the controller can be accessed via an external DMX controller It will be necessary to have the DMX address set on the ILUMICON controller The controller operates on four channels of DMX control ILUMICON User Manual Rev 02 DMX Channel Values Channel Value Function 000 010 011 030 031 040 041 060 061 070 071 090 091 100 101 120 121 130 131 150 151 160 161 180 181 190 191 210 211 220 221 255 000 127 128 255 ILUMICON User Manual Rev 02 Blackout Wash 1 Blackout Wash 2 Blackout Wash 3 Blackout Wash 4 Blackout Wash 5 Blackout Wash 6 Blackout Wash 7 Blackout Wash 8 Blackout Effect 1 Blackout Effect 2 Blackout Effect 3 Blackout Effect 4 Blackout Effect 5 Blackout Effect 6 Blackout Effect 7 Blackout Effect 8 Blackout Custom 1 Blackout Custom 2 Blackout Custom 3 Blackout Custom 4 Blackout Custom 5 Blackout Custom 6 Blackout Custom 7 Blackout Custom 8 OFF ON Operation 15 Technical Information ILUMII 5 Technical Information Product Maintenance To maintain optimum performance and minimize wear clean the product frequently Usage and environment are contributing factors in determining the cleaning frequency As a general guideline the product should be cleaned at
10. ble programs 8 static 8 kinetic Four channel DMX 512 protocol controller I channel Wash programs 2 channel Effect programs 3 channel Custom programs 4 channel On Off Controls up to 66 products with ID addressing Eight user programmable shows with 100 steps each Individual pod control Playback schedules via internal clock LCD display with password protection Product Overview DMX In TG DMX Out Power Input Controller Output On Off Switch Programming Buttons 2 ILUMICON User Manual Rev 02 ILUMINARG Product Description Product Dimensions ZE 2 0 in e 52 mm 4 9 in 125 mm ILUMICON User Manual Rev 02 5 3 Installation AC Power The ILUMICON Controller has an external voltage adapter that provides it with 12 Always connect the ILUMICON and its controlled fixtures to a protected VDC 500 mA minimum The input voltage for this voltage adapter is set to match the circuit with an appropriate mains voltage where the ILUMICON will operate Please refer to the sticker on the electrical ground to avoid voltage adapter for more information the risk of electrocution or i fire Make sure that you are connecting the ILUMICON to the proper voltage as per the specifications in this User Manual or on the products sticker Never connect the ILUMICON to Power Consumption a rheostat variable resistor or To determine the power requirements for the ILUMICON see the label
11. e most recent Start time will always override the existing previously executed program ILUMICON User Manual Rev 02 13 Operation Settings DMX address This function sets the DMX address for the controller It is addressable 001 250 Range Enter the number of products connected in series Allow edit This function either enables or disables editing in Wash Effect and Custom programs Detect device This is the manual method of detecting and connecting the controller to all new products in series It is generally used when you add more products to an existing system Turning off and then on the controller has the same effect Reset to factory settings This function will reset all the settings to the factory defaults except for Custom programs Factory Default Settings Setting Default Schedule All times in schedule are reset to 00 00 Wash program Step times and fade times are reset to 001 Effect program Speeds are reset to 001 DMX address DMX address is reset to 001 Range Range is reset to 066 Allow edit Reset to Yes Password ON OFF Password is reset to OFF Password is reset to 00000000 Set password Down 0 Up 1 Activating Password Mode Set Password function to ON This will prompt the user for a password every time the controller is powered on Toggle to Set password function in order to change the password Input an eight digit password using the UP amp DOW
12. ersonal Safety e Always disconnect this product from its power source before servicing e Always connect this product to a grounded circuit to avoid the risk of electrocution e Do not touch this product s housing when operating because it may be very hot Mounting and Installation e This product is for indoor use only To prevent risk of fire or shock do not expose this product to rain or moisture e Make sure there are no flammable materials close to this product while it is operating Power and Wiring e Always make sure that you are connecting this product to the proper voltage as per the specifications in this manual or on the product s sticker e Never connect this product to a dimmer pack e Make sure that the external voltage adapter or power input cable is not cracked crimped or damaged e Never disconnect this product by pulling or tugging on the power input cable Operation e The maximum ambient temperature is 104 F 40 C Do not operate this product at a higher temperature e In case of a serious operating problem stop using this product immediately ILUMICON User Manual Rev 02 LUMI NARC Product Description 2 Product Description The ILUMICON is a 4 channel proprietary DMX controller capable of using ID addressing to control up to 66 ILUMINARC products The ILUMICON consists of a main control module and an external power adapter Features ILUMICON User Manual Rev 02 16 edita
13. f time is 5 seconds and it can be adjusted 001 255 Effect Program Select from the eight existing Effect programs and it will instantly play Vary the Speed of the effect 001 255 Custom Program Select from the eight existing Custom programs and it will instantly play Enter the Edit section to create or edit program You can create or edit up to 100 scenes To program less than 100 scenes set the Step time of the scene after your last scene to 0 Select the ID address of the target product Setting ID address to 0 selects all products in the serial link Color Effects combination for different IDs is allowed Specify the Module or modules to run active 0 123 1 1 Z 3 3 4 1 2 JE 23 6 1 3 RGB mix using the Red Green and Blue functions and adjusting the range between 0 and 255 Select a Strobe speed from 0 20 Hz if desired Select the Step time for the current scene Step time unit values Range 0 10 0 1sec per unit Range 11 255 1 sec per unit Set a Fade time for the current scene in one second increments from 0 to 255 Play Schedule Simply activate this menu Play schedule to run Clock Clock D Time now To view the current time on the controller Clock Edit now Edit the time and date Schedule There are 24 Wash Effect and Custom programs that can be set with Start and End times Start times take priority over End times programs will not overlap Programs with th
14. first DMX cable coming from the controller to the DMX Input connector 3 pin male of the ILUMICON 3 Connect the 3 pin male connector of the second DMX cable to the DMX Output connector 3 pin female of the ILUMICON 4 Connect the 3 pin female connector of the second DMX cable coming from the ILUMICON to the DMX Input connector of the first DMX compatible product 5 Continue linking the other DMX compatible products in the same way DMX Connection Diagram DMX Output Universal DMX Controller SCENES Manual OA BANK TAP Display Bankcopy O Override O First DMX Cable Second DMX Third DMX Cable Cable ILUMICON First DMX Fixture Next DMX Compatible Product ILUMINARC Products ILUMICON Output Cable ILUMICON User Manual Rev 02 7 Installation Always keep the Q power cables away from the signal cables by running them in different conduits and using separate distribution boxes LUMINARC Installation Notes The ILUMICON consists of two parts the controller housing and the external power adapter The controller housing is IP20 rated Setup Product Control Panel Setup Activate ID addressing in each product by setting panel function ID ON OFF to ON MENU Settings ID ON OFF ON Set ID addresses in each product by setting panel function ID address to incremental values 1 e 1 2 3 4 5
15. h iluminarc com World Wide Web www iluminarc com ILUMICON User Manual Rev 02 Technical Information ILUMICON User Manual Technical Specifications Dimensions and Length Width Height Weight 7 in 178 mm 5 2 in 131 mm 2 in 51 mm Note Dimensions in inches rounded to the nearest decimal digit Electrical Power Supply Type Range External power adapter 120 230 V 50 60 Hz Parameter Consumption 13 W Max Thermal Max External Temperature 104 F 40 C Control amp I O Connectors Connector Type Programming 3 pin XLR Sockets Ordering ILUMICON 5555502 1 f V m Fk M N A 1 R NARC FE Ni LU Weight 1 Ib 0 5 kg Channel Range 1 2 3 4 ILUMINARC ILUMINARC 5200 NW 108th Avenue Sunrise FL 33351 U S A Voice 954 923 3680 www iluminarc com ILUMICON User Manual Rev 02 January 2012 ILUMICON User Manual Rev 02 Technical Information LUMINARC 19
16. le must have the following characteristics 2 conductor twisted pair plus a shield Maximum capacitance between conductors 30 pF ft Maximum capacitance between conductor and shield 55 pF ft Maximum resistance of 20 ohms 1 000 ft Nominal impedance 100 140 ohms Cable Connectors Cabling must have male and female XLR connectors p Renson 120 ei phm T beten Gen DMX and vi pan 3 OME af m Pe hast focure DMX connecter conf guration COMMON pty ri Termination reduces signal enor Ta avoid tig nal tr n mistan problems and interference itis always advisable to connects DMX signal Cable Connectors If you use a controller with a 5 pin DMX Output connector you will need to use a 5 pin to 3 pin adapter Iuminarc Model No DMX5M or DMX5F 3 PIN TO 5 PIN CONVERSION CHART Conductor 3 Pin Female output 5 Pin Male Input Ground Shield Pin 1 Pin 1 Data signal Pin 2 Pin 2 Data signal Pin 3 Pin 3 For further information on cabling for DMX including how to set up a DMX serial data link download the DMX Primer from the ILUMINARCO website at www iluminarc com ILUV Installation F ji u A 5 I L T WW i V i j k i T i m _ 4 P a A W zj Mounting Before mounting this product read and follow the safety recommendations indicated in the E Make sure there Safety Notes Always mount this product i
17. n a safe position making sure there is adequate room is a suitable for ventilation configuration and maintenance power outlet for the ILUMICON s i voltage adapter near the Installation location where you will The ILUMICON consists of a main unit and an external power adapter ILUMINARC t the ILUMICON unit ee eeler SP recommends following the general guidelines below when mounting the ILUMICON e Consider ease of access to the product for operation programming adjustments and routine maintenance e Never mount the product in places where rain high humidity extreme temperature changes or restricted ventilation may affect it Procedure You should mount the ILUMICON s baseplate on a flat dry surface whether plywood or other suitable material The ILUMICON s detachable baseplate has four holes to accommodate regular screws for this purpose In any case remember the recommendations indicated above regarding access to the product and necessary room for ventilation The diagram below shows the detachable baseplate and its three nipples These must slide all the way inside the corresponding slots on the back of the ILUMICON to ensure a Safe unit rigging ILUMICON Baseplate rd Output Nipples ILUMICON Mounting screws ILUMICON User Manual Rev 02 ILUIV IN VAR IL 4 Operation When programming live performances as well as cues that need to trigger on demand or on a timeline program no more than
18. nes the fade time for each 001 255 program step Effect 1 i i Defines the speed of the effect Effect program Edit Effect 8 i 001 100 program ID address 000 066 0 all units Step time 000 255 Fade time 000 255 Custom 1 Custom program Edit Red 000 255 Scene 1 Custom 8 Scene 100 Green 000 255 Blue 000 255 Module 001 006 Strobe 000 020 Play schedule Schedule Activates pre configured schedule s 12 31 2006 Shows current time and date 13 50 24 Clock Edit time 12 31 2006 Edits time and date 13 50 24 Wash 1 Wash 8 Effect 1 Sets the daily schedule for Schedule STAN Ser Ene each Wash Effect and Custom Eff 00 00 gt gt 00 00 ect 8 program Custom 1 Custom 8 DMX m 001 250 Sets the units DMX address 001 100 Limits the ID address range Allow edit YES NO Allows or denies editing Settings Detect D fic dev der er gt gt gt etects a specific device Reset to Defaults the COLOR CON to Factory ME its factory settings settings ONOFF ON OFF Sets the unit s password re Password ILUMICON User Manual Rev 02 D F Pr KEN Fu myg k H Ai In Kr L E i F t va i E LUMINARC Operation Wash Program Select from the eight existing Wash programs and it will instantly play Set the Step time and the Fade time in the Edit function if desired The unit o
19. tion configuration or operation information Failure to comply with this information may render the product partially or completely inoperative damage third party equipment or cause harm to the user This icon indicates important installation or configuration information Failure to comply with this information may prevent the product from functioning correctly This icon indicates useful non critical information The term DMX used throughout this document refers to the USITT DMX512 A transmission protocol What Is In The Box e One ILUMICON e One External Voltage Adaptor 12 VDC output e One IP66 to DMX Cable Adaptor e One Warranty Card e One User Manual Unpacking Instructions Immediately upon receiving a product from ILUMINARC carefully unpack the carton Check the contents of the box to ensure that all parts are present and that they are in good condition Claims The carrier is responsible for any damage incurred during shipping Therefore if the received merchandise appears to have been damaged during shipping the customer must submit the damage report and any related claims to the carrier not ILUMINARC The customer must submit the report upon receipt of the damaged merchandise Failure to do so in a timely manner may invalidate the customer s claim with the carrier For other issues such as missing components or parts damage not related to shipping or concealed damage the c
20. ucts on a A serial data link must be daisy chained in one single line To comply with the EIA 485 standard no more than 32 devices should be connected on one data link Connecting more than 32 products on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal Make sure to mount this product away from any flammable material as indicated in the Safety Notes A contact between the common and the product s chassis ground Grounding the common can cause a ground loop and your fixture may perform erratically Test cables with an ohm meter to verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other Do not allow ILUMICON User Manual Rev 02 Installation Product Linking Use a serial data link for one or more products using a DMX 512 controller or products set to Master Slave operating mode The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support Maximum recommended serial data link distance 500 meters 1 640 ft Maximum recommended number of fixtures on a serial data link 32 fixtures Data Cabling DMX Data Cable Use a BeldenO 9841 or equivalent cable which meets the specifications for EIA RS 485 applications Standard microphone cables cannot transmit DMX data reliably over long distances The cab
21. ustomer must make claims to ILUMINARC within seven 7 days of receiving the merchandise Text Conventions Convention Meaning 1 512 A range of values in the text 50 60 A set of mutually exclusive values in the text TLUMICON UM The name of another publication or manual lt SET gt A button on the product s control panel Settings A product function or a menu option MENU gt Settings A sequence of menu options 1 10 A range of menu values from which to choose in a menu Yes No A set of two mutually exclusive menu options in a menu ON A unique value to enter or select in a menu ILUMICON User Manual Rev 02 1 Introduction Safety Notes Please read all the following Safety Notes carefully because they include important information on how to install use and maintain this product safely There are no M user serviceable parts inside this product Any reference to servicing you may find in this User Manual will only apply to properly certified ILUMINARC technicians Do not open the housing or attempt any repairs unless you are certified to do so LU Please refer to all applicable local codes and regulations for the proper installation of this product E Keep this manual for future consultation If you sell this product to another user make sure that they also receive this manual In the unlikely event that your ILUMICON may require service please contact ILUMINARCA Technical Support P