DSP Multipower 5-6
Contents
1.
2. Relative humidity non condensation 30 90 13 3 4 Terminal Block Explanation Tower model 3 3 Installation of Accessories Kit OUTPUT INPUT BYPASS DIMTYPE ONLY oe nee ae nai a ar or Moe UTILITY INPUT L11 N1 BYPASS INPUT DIMTYPEONLY L12 N1 UTILITY INPUT G1 INPUT EARTH GROUND N22 L22 N21 L23 L21 UPS OUTPUT G2 OUTPUT EARTH GROUND Rack 5 6K OUTPUT INPUT GOCCIA L21 N22 UPS OUTPUT L12 N1 UTILITY INPUT G2 OUTPUT EARTH G1 INPUT EARTH GROUND GROUND Rack 10K
3. 5K 6K with batt N Model Lop Display WALA AT D Green LED lights up to indicate the UPS DAUT DAT N _ id tS ey has the capability to run under redundancy n Les mode Green LED steadily lights up to indicate that 7 the utility input voltage is within the window Eor MH KDA x 1 oaee the LED flashes flickeringly to indicate that QQQ G e CQ ATUL ATOLL fal 2 the utility input voltage is within the 7 HA L acceptable window areen LED lights up to indicate Bypass Input i a 7 P is normal a UPS ON Alarm Silence Go to Previous page or change the setting ANG ANGOLI Di J a el N of the UPS To reconfirm the change of UPS Setting CT R a ar Go to next page AOA A A U UPS OFF Switch Special Functions log in out QD UPS is working under ECO Economic Mode UPS fault or Abnormal STIL Vg Ke yvy2FTQmIMOY NW SY RS232 Port Terminal Resistor for Parallel function CAN Bus Connection Port for Parallel System Customer Options Slot 1 Customer Options Slot 2 Cooling Fan External Battery Connector Utility Inout Breaker C
4. 14 15 e L12 N1 the terminal for Utility Input to provide the power source when the UPS is working under Utility mode e G1 the terminal for UPS Input Ground 5 Please refer to the specs of input current output current and recommended e L21 L23 N21 L22 N22 the terminals for UPS Output conductors listed as below e G2 the terminal for UPS Output Ground a AC input and output e Use Mounting Cable Tie to fix cables 5 6KVA 33A AWG 9 Tower model 5 6K model 6K Rack Model j Tg b Battery input 5 6KVA 25A AWG 10 10KVA 41A AWG 10 16 17 3 5 Operation Test and Installation Instruction 3 5 1 Start Up in Normal Mode 3 5 1 1 Open the terminal block cover on the rear panel refer to 2 3 2 Before Start the installation please make sure the grounding is connected properly 3 5 1 2 Make sure Utility breaker UPS Utility breaker is On Off position 3 5 1 3 Make sure the voltage of Utility matches with the input voltage window of the UPS 3 5 1 4 Connect the Utility separately to the terminal blocks of UPS Utility and Bypass Inputs Switch on the Power Breaker of the distribution panel and the breakers of the UPS Utility and Bypass Inputs and then the UPS starts up Green LEDs cx amp cx light up to show the Utility and Bypass Inputs are normal and the LCD display with parallel function will illustrate from drawing A1 drawing A2 to drawing
5. ders 6 2 4Installation Position slot1 30 31 6 3 USE USB card 6 3 1CN1 for USB 6 3 2Definition P 6 3 3Comply with USB version 1 0 1 5Mbps 6 3 4Comply with USB HID Version 1 0 6 3 5The Pin Assignments of the USE card 1 gt VCC 5V 2 gt D 32 gt D 4 gt Ground 6 3 6Installation Position slott CHA CN3 or slot 2 CHB CN4 6 4 DCE Dry Contact B card 6 4 1 The pin assignments of 10 Pin Terminal 1 2 3 4 5 6 7 8 9 10 Pin 1 UPS on Bypass mode Pin 2 Utility Normal Normal close contact Pin 3 Utility Normal Normal open contact Pin 4 Inverter On Pin 5 Battery Low Pin 6 Battery Bad or Abnormal Pin 7 UPS Alarm Pin 8 Common Pin 9 Shutdown UPS positive signal Pin 10 Shutdown UPS positive signal 6 4 2 The shutdown function will be activated after a 6 25Vdc Is put between pin9 and pin10 for 5 seconds 6 4 3 The capacity of each relay contact is 40Vdc 25mA 32 6 4 4Installation Position slot1 CHA CN7 or slot 2 CHB CN8 6 4 5Flexible signal output for N C Normal close or N O Normal open contact by shorting pin1 2 or pin2 3 from JP1 5 6 4 6 The shutdown function will be enabled in 1 minute after blackout occurs if the pin1 2 of both CN1 and CN6 be shorted by cap Or the shutdown function can only be enabled by pin9 10 of CNS if the pin2 3 of both CN1and CN6 be shorted by cap Refer to 6 4 2 6 5 SNMP Cards 6 5 1 SNMP WEB card 6 5 1 1 For
6. B Otherwise the LCD display will illustrate from drawing A2 to drawing B Al A2 B l LINE UPS LOAD I C 18 3 5 1 5 Then the UPS is on Bypass Mode now and it will proceed self test automatically If there is no abnormal message occurred it means the pre startup of the UPS is successful and the charger starts to charge the batteries 3 5 1 6 Press the UPS On Switch for approx 3 seconds then the Buzzer sounds twice and the LCD display changes from drawing B to drawing C 3 5 1 7 A gt s SS V C LINE UPS LOAD l ey FECI Lf 3 5 1 8 Then the UPS is under self test mode again the LCD display will illustrate from drawing C to drawing D and remain approx 4 seconds under battery mode then illustrate from drawing E1 to drawing F if the self test is successful It shows test E1 re LINE UPS LOAD C It shows OK in self test E2 LINE UPS LOAD T D D L 7 i It shows Fail in self test 19 F It shows 220Vac in Utility Input 3 5 1 9 In case of failure in self test the LCD display will illustrate from Drawing D to drawing E2 then an error code or error status will be shown on the screen 3 5 1 10 Your start up operation of the UPS is completely now Make sure the UPS is plugged onto the wall receptacle for charging at least 8 hours and the batteries of the UPS are fully charged 3 5 2Start up in Battery Mo
7. UPS and Batteries 1 25 Intended for Installation in a Controlled Environment 1 26 CAUTION A disconnect switch shall be provided by others for ac output circuit To reduce the risk of fire connect only to a circuit provided with branch circuit overcurrent protection for 30 amperes rating in accordance with the National Electric Code ANSI NFPA 70 1 27 CAUTION To reduce the risk of fire unit input connect only to a circuit provided with branch circuit overcurrent protection for 40 amperes rating in accordance with the National Electric Code ANSI NFPA 70 1 1 28 Use No 10 AWG 60 C copper wire and 22 1 Ib in Torque force when connecting to terminal block _ oh ee oh 1 2 Storage Instruction For extended storage through moderate climate the batteries should be charged for 12 hours every 3 months by plugging the UPS power cord into the wall receptacle and turn on input breaker on front panel Repeat this procedure every 2 months under high temperature environment 2 1 15 In case the UPS is out of order Fault status will be shown on the LCD 2 Product Introduction screen 2 1 16 When the UPS is operated under CF50 or CF60 mode the 2 1 General Characteristics recommended load connected shall be 75 of rated capacity if the input 2 1 1 True online architecture continuously supplies in your critical device with a voltage is 176 280Vac and 50 of the rated capacity if the input voltage is stable regulated transi
8. installation please refer to the user s manual attached with the card 6 5 1 2 Installation 6 5 1 3 Position slot 2 CHB 6 5 2Net Agent II Internal Card 6 5 2 1 For installation please refer to the user s manual g MEAE attached with the card 6 5 2 2 Installation 6 5 2 3 Position slot 2 CHB 33 7 Specifications Self Diagnostics Upon Power on Front Panel Setting amp Software Control 24 hour routine checking ALARMS Audible and Visual Line Failure Battery Low Transfer to Bypass System Fault Conditions PHYSICAL Dimensions 440x88x680 440x176x680 Model 5000VA 6000VA 10000VA_ Voltage Window Frequency Phase Wire Power Factor Current THD lt 5 at 100 Linear Load Voltage Window 220 230 240Vac Selectable 208 120Vac optional Voltage Adjustment 0 1 2 3 Capacity 3500W 4200W 7000W These cards are not suitable to use simultaneously Rated Power Factor 0 7 Lagging Wave Form Sine Wave THD lt 3 no load to full load Frequency Stability 0 2 Free Running Frequency Regulation 1 3 Transfer Time Crest Factor Efficiency AC to AC Normal Efficiency AC to AC ECO Up to 93 Autonomy gt 5 min DC Start Type Sealed Lead Acid X Maintenance Free 12V 7AH z HxWxD mm 440x176x680 Input Output Connection Hardwire External Battery Connection Plug in amp Play Net Weight Power modue 83 Kgs Withbattey 55 Leakage Current lt 3mA at Full Load Mar
9. not open the case as there are no serviceable parts inside Your Warranty will be void 1 1 7Do not try to repair the unit yourself contact your local supplier or your warranty will be void 1 1 8Please make sure that the input voltage of the UPS matches the supply voltage 1 1 9Use a certified input power cable with the correct plugs and sockets for the appropriate voltage system 1 1 10 To eliminate any overheating of the UPS keep all ventilation openings free from obstruction and do not store things on top of the UPS Keep the UPS 30 cm away from the wall 1 1 11 Make sure the UPS is installed within the proper environment as specified 0 40 C and 30 90 non condensing humidity 1 1 12 Do not install the UPS in direct sunlight Your warranty may be void if the batteries fail 1 1 13 Install the UPS indoors as it is not designed for installation outdoors 1 1 14 Dusty corrosive and salty environments can do damage to any UPS 1 1 15 Install the UPS away from objects that give off excessive heat and areas that are excessively wet 1 1 16 If liquids are split onto the UPS or foreign objects dropped into the unit the warranty will be null and void 1 1 17 The battery will discharge naturally if the system is unused for any length of time 1 1 18 It should be recharged every 2 3 months if unused If this is not done then the warranty will be null and void When installed and being used the batteries will be automatically rech
10. B1 Input Output Terminal Block EPO Emergency Power Off Short to enable the function Air Ventilation Hole 10 2 4 Communication Port Explanation The Communication port on the UPS provides true RS232 type to communicate with UPS software to remote monitoring the power and UPS status With optional interfaces cards which contains R2E 2 RS232 plus EPO RSE RS485 plus EPO USE USB plus EPO DCE Dry Contact plus EPO as well as SNMP card you may combine them according to your demand However the R2E card RSE card and USE card are prohibited to be used simultaneously The bundled software of the UPS is compatible with many operating systems such as Windows 98 amp 2000 ME NT and XP When the optional interface cards are used with onboard RS232 port in communication the shutdown command at the DCE card amp also the EPO signals will get the highest priority in control command then the SNMP WEB card then R2E RSE and USE get the lowest priority 2 4 1 True RS2382 type 2 4 1 1 The RS232 interface settings The RS232 interface shall be set as follows Baud Rate 2400 bps 2 4 1 2 The Pin Assignments of true RS232 type The Pin Assignments of true RS232 type are illustrated as follows Pin 3 RS232 Rx Pin 2 RS232 Tx Pin 5 Ground 1 3 Installation and Operation The packing condition and the external outlook of the unit should be inspected carefully before installation Retain the packing material f
11. DSP MULTIPOWER Single phase in Single phase out 5 6 10k VA USER MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS inform 1 1 12 PAP 22 25 2 4 AP 3 2 3 3 3 4 3 4 1 del 52 6 1 Did 6 3 6 4 6 5 Table of Contents Important Safety IMstruction ccccc cece cece cece cece cece cece cece eee ens 2 An Important INOUMC 6 cy roxeescsgosaestamnene cancesnetunsetastocainenansorasvante 2 Stora DSM UCOren EESE 3 Product Introduction vc dco sve soeuceveswadeducceuswnuedcueerieieocedumascetwecnsniee 4 General CharacterisuCs s ncowessinesoyeeresncodseuesstaieeasientyseaneriandonsee 4 Symbols on the LCD Display Panel ccc ccc cc cece eee eee ee ees 5 Panel ex Pla aIOM oscc0 Weaun cei eawnienaasravedoxteennedsedian sms pydaeseneutsaceas 8 Communication Port Explanation cccccce cece cece eeeeeeeeeeeees 1 Installation and Operation cccc cece cece cece cece cece cece eee eee e eee e ens 12 DAC NAG x5 oh aca ctninontandcantasesamscdetucadsus sitanendiet ont ctundentescce tes 12 Selecting Installation POSItiON ccc cece cece cece cece eee eeeeeeeeeeeees 13 Installation of Accessories Kit ccccccc cece eee cece e eect eee e eee eeenes 14 Terminal Block Explanation ccccccce cece cece e eee eeeeeeeeee eens 15 Operation Test and Installation Instruction cccceeeeeeeeeeeeees 16 Troubleshooting Gui x4ca dedscaani
12. arged and kept in top condition 1 1 19 This UPS supports electronic equipment in offices telecommunications process control medical and security applications Non authorized technician is not allowed to install the UPS in the following areas a Medical equipment directly related to human life 2 b Elevator Metro Subway system or any other equipment related to human safety c Public system or critical computer systems 1 1 20 Do not install the UPS in an environment with sparks smoke or gas 1 1 21 Make sure the UPS is completely turned off when moving the UPS from one place to another It might cause electrical shock if the output is not cut completely 1 22 The UPS offers CVCF Constant Voltage Constant Frequency setting function To set RT series to be a CVCF shall be required by a qualified technician Ss a For correct setting and wiring please contact with your local agent b Do not do it by yourself otherwise your warranty will be void a s 1 23 This UPS has been designed and constructed to protect your assets from the wide range of power aberrations experienced on Utility power lines today It is your insurance for reliable clean and stable voltage supply It is worth taking care to install the system correctly and to have it maintained correctly by your local dealer 1 24 SAVE THESE INSTRUCTIONS This Manual Contains Important Instructions that should be followed during Installation and Maintenance of the
13. can be 184Vac 260Vac or 195Vac 260Vac 3 5 5 5 Drawing T means the bypass frequency window of the Inverter Output the acceptable setting values are 3Hz and 1Hz 3 5 5 6 Drawing U means the acceptable Inverter Output Voltage of which voltage is 200Vac 208Vac 220Vac 230Vac or 240Vac 3255 7 Drawing V1 V2 V3 and V4 mean the operation modes of the UPS of which alternative is Online Eco Economic mode fixed 50Hz Output or fixed 60Hz Output 3 5 5 8 Drawing W means the adjustments of the Inverter Output which may be calibrated as 0 1 1 2 2 3 or 3 3 5 5 9 Drawing X means a specified address amp position of the UPS when the UPS is in Parallel mode The settable numbers are from ist to 4th The number must be 1 if the UPS is not in parallel 3 5 5 10 Drawing Y means the parallel function status The P 01 means parallel function disabled and the P02 means parallel function enabled 35 511 When all the setting changes are done you have to press enter key Pad to save all the changes when the LCD screen shows as drawing Z then the LCD screen will show as drawing AA to complete the setting changes If you don t want to change those settings you may press OFF 5 key pads for 5 seconds then the LCD screen turns to Drawing AA directly which means your setting changes are invalid Please press Enter key to save data AA It shows the UPS is locked 3 5 5 12 Turn Off the breake
14. de Cold Start 3 5 2 1 Make sure the UPS you have has already been installed at least 1 set 20pcs of 12V 7AH or 12V 5AH batteries 3 5 2 2 Push the UPS On Switch once for approx 5 seconds to awake the ups and then the buzzer sounds twice The LCD display will illustrate from drawing A to drawing G and keep awake for approx 15 seconds 3 5 2 3 Press the UPS On Switch of the UPS again for about 3 seconds till the LCD display illustrates from drawing G to drawing H then the UPS will be in self test Mode The UPS may offer energy to the output in a minute and the LCD display illustrates as drawing I In case of failure in pushing the UPS On Switch in 15 seconds the UPS will automatically turn off You then have to go through step 3 5 2 1 to 3 5 2 3 once again G LINE UPS LOAD a E x c TUE It shows Off which means the UPS pre start is successful 20 H LINE UPS LOAD l LINE UPS LOAD A 3 5 3Check Measured Values amp Figures detected by UPS 3 5 3 1 If you would like to check the measured values amp figures detected by the UPS please use scroll up O and scroll down 4 key pads When you use scroll down key pad the LCD display will illustrate as Drawing C Voltage from Utility Input gt Drawing 11 Voltage from Bypass Input gt Drawing J Frequency from Utility Input gt Drawing K Frequency from Bypass Input gt Drawing L UPS Output Voltage gt Drawing M UPS Output Freque
15. ent free pure sine wave AC Power 160 280Vac 2 1 220KHz PWM sine wave topology yields an excellent overall performance The high crest factor of the inverter handles all high inrush current loads without a need to upgrade the power rating 2 1 3Multi functional LCD LED panel may display various status of the UPS 2 2 Symbols on the LCD Display Panel The LED display may show UPS working status Utility Status and UPS Abnormal status in the mean while the LCD display may show Input Output oo Voltage Frequency Load Status Inner cabinet temperature and Abnormal mcm __peeron Phenomenon 2 1 4To protect the unit from overloading it automatically switches to bypass UNE Utilityor Bypass Source or Bypass Utilityor Bypass Source mode in 160seconds app 40msec if loading is at 105 150 of rating and in case of overloading at 150 of rating it switches to bypass mode Ja e immediately It will automatically switch back to inverter mode once overload 2 1 5Should the output becomes short circuit the UPS holds the system and cuts the output automatically till the short circuit situation is removed manually 2 1 6Should the unit become overheated the internal thermal Switch will detect EEE power the heat and switch to bypass mode and vice versa 2 1 7 Fully digitalized control circuit built in the UPS may upgrade the igitali ircuit built i sl amp UPS Working in specified mode functionality Of the UPS as well as reach a high level protect
16. ion of the UPS Through powerful Communication capability built it enhances its ability for remote control and monitoring easily x A Blackout Transfer occurred in UPS Output 2 1 10 DC start function makes sure of the start up of UPS during power eel Ay Si inou ona outages Np status to adjust battery cut off point and extend the life of batteries oF UPS Shutoff 2 1 12 Intelligent temperature controlled fan may not only extend the life of the e screen directly which may reduce down unnecessary repair DEIS UPS Flow Chart ask a lot E Low 2 1 8Maintenance free sealed type battery minimizes after sales service 2 1 9Providing four different working modes such as Normal ECO CF50 and Bypass Input Abnormal UPS fails to transfer CF60 it may widely be used in a variety of applications to bypass Bypass Abnormal at ECO mode 2 1 11 Revolutionary battery management circuit analyzes battery discharging fan but also reduce annoying noise because of sudden fan spin It remains your office quiet and comfortable as usual LINE UPS Abnormal Lock 2 1 13 When UPS is out of order you may read out the possible fault reason 2 1 14 When UPS is out of order you may read out the possible fault reason LN from the LCD screen directly which may reduce down unnecessary repair H ny Ms 4 Digits Measurement Display task a lot C at et ee Po one On On one edt omens ee werent PO Emergency Power Off eS Battery Weak or Dead ee Output Shor
17. ithin the input window of the UPS In case problems or symptoms still exist please proceed the followings for proper adjustment Should the problem persists please contact your local distributor for help 28 29 UPS fails to offer If the backup time is still too short 5 Bundled Software Installation Guide battery backup or its after 8 hours of charge please back up time is shorter contact your local distributor for than its calculation battery replacement 5 1 Hardware Installation UPS locks itself and it Please refer to chapter 3 5 6 to 1 Connect the male connector of RS232 cable to the UPS communication port can not be turned off trouble shoot the problem 2 Connect the female connector of the RS232 cable to a dedicated RS232 port otherwise consult your local of the computer distributor for help 3 For optional interface cards you may refer to Chapter 6 for installation 5 2 Software Installation Please refer to the user s manual of the software for installation 6 Customer Options Slots 6 1 R2E 2nd RS 232 card 6 1 1CN1 is for RS232 DBY 6 1 2For communication protocol please refer to Chapter 2 4 1 6 1 3Installation Position slot1 CHA CN4 or slot 2 CHB CN5 6 2 RSE RS 485 card 6 2 1CN1 is for the function of the terminal resistor Short pini 2 to enable the function and short pin2 3 to disable it 6 2 2 CN2 for RS485 and CNS for remote power 6 2 3Definition 53 See 3 gt B Data
18. ks S CE cUL UL Quantity 240Vdc Recharge Time 4 hours to 90 5 hours to 80 CEE DISPLAY i O DA 192321132015001 Status On LED LCD Line Mode Backup Mode ECO Mode Bypass Supply Battery Low Battery Bad Disconnect Overload Transferring with interruption amp UPS Fault Readings on LCD Input Voltage Inout Frequency Output Voltage Output Frequency Load Percentage Battery Voltage amp Inner Temperature 34 35
19. ncy gt Drawing N UPS Output Load gt Drawing O UPS Battery Voltage gt Drawing P UPS Inner Temperature LINE UPS LOAD A It shows frequency from Utility Input 21 It shows UPS output frequency LINE UPS LOAD A It shows UPS output load level LINE UPS LOAD gt C It shows Battery Voltage 22 A P LINE UPS LOAD l LI d T It shows UPS Inner Temperature 3 5 4UPS Default Data and Special Function Execution 3 5 4 1 After UPS completely starts up press key pad to change the LCD display screen to drawing Q1 Q1 Q2 It shows buzzer Off 3 5 4 2 Press O key pad to scroll down the screen and check the UPS settings The LCD display will show in consequence between Drawing Q1 buzzer gt Drawing R1 Self test gt Drawing S1 Bypass Voltage Windows gt Drawing T Output Frequency Synchronization Window gt Drawing U Inverter Output Voltage gt Drawing V1 UPS Operation Mode gt Drawing W Output Voltage Micro Tune Value gt Drawing X UPS Id gt Drawing Y Parallel function status 23 kaon It shows self test is NOT on i Erun It shows self test is On l Sto It shows Bypass Voltage is adjusted to narrow one S2 It shows bypass voltage is adjusted to wider one It shows Frequency Window is 3Hz 24 It shows inverter output voltage i EI It
20. ng operation you may check the followings a Are the wirings of input and output correct Check Items Check the error code shown on the LCD screen 1 Er05 Eg 2 Er06 Er10 Er12 Er28 amp SO 3 EPO 4 Er11 Er33 5 Er14 6 Er15 7 Er16 Er27 8 Er21 9 Er24 10 other error code Check to see if the battery connection is properly done then re charge the batteries for 8 hours to see whether the UPS may backup normally otherwise consult your local distributor right away If the CB3 is tripped please turn off the UPS completely and keep the CAM switch at position INV before pressing CB3 Then remove some uncritical load at the UPS output end If any damage of the coating of AC power cord please replace a new one 3 Remove the short circuit occurred at the EPO terminal 4 Remove the objects blocked onto the ventilation holes 5 Check the cooling FANs on rear panel are working normally 5 Make sure the UPS is operated normally If it is on CVCF mode you have to turn off and turn on the UPS again 6 All of parameters except ID Number in the parallel UPS must be same Please refer chapter3 5 5 to set them again 7 Reconnect the RJ 45 wire or set a UPS with ID 1 8 When the UPS is on CVCF mode it is prohibited to have bypass input You have to turn off the UPS and bypass input and re start the UPS 9 Consult your local distributor for help b If the input voltage of the Utility is w
21. or future use 3 1 Unpacking 3 1 1 Unwrap the pack of UPS 3 1 2 Take the UPS out of the PE foam 3 1 3Standard Package includes gt 1 set of Quick Start Manual gt 1 set of User s Manual gt 1 set of UPS communication software with RS232 cable gt 1 set of accessories pack 3 1 4Package for the UPS with Isolation transformer amp dual input gt Ditto but with additional 3pcs wire No 7 3 1 5Package for the UPS without isolation transformer but dual input gt Ditto but with additional 1pcs wire No 7 p s Wire No 7 is to be used at the input output terminal block of the UPS Please refer to Chapter Hata Ba vuru kayna bulunamad for installation Power Module model 4 x4 x1 l PM10K only 3 2 Selecting Installation Position It is necessary to select a proper environment to install the unit in order to minimize the possibility of damage to the UPS and extend the life of the UPS Please follow the advice below 1 Keep at least 30cm 12 inches clearance from the rear panel of the UPS to the wall 2 Do not block the air flow to the ventilation openings of the unit 3 Please check the installation site to avoid overheat and excessive moisture 4 Do not place the UPS in an environment near dust corruptive or salty material or flammable objects 5 Do not expose the UPS to outdoors
22. r of Utility Input 3 5 5 13 Your Setting changes are complete 21 3 5 6UPS Is Off Due to Unknown Reason and Its Trouble Shooting UPS Red Fault LED 3 5 7 lights up 3 5 7 1 If there is a serious abnormal condition occurred the UPS will lock it itself in OFF position as shown in drawing AA and a abnormal message will show on the LCD screen SO Aer After 3 seconds all messages will be locked except Bypass messages LEDf J 2 amp LCD Incase the Utility is abnormal after the UPS is locked the LEDI 2will be extinguished and the LCD_ will be shown on the LCD screen 3 5 7 3 To release the UPS lock please proceed the followings 3 4 6 3 1 Check those error messages recorded 3 4 6 3 2 Check to see Chapter 2 2 to trouble shoot the problem of the UPS Otherwise consult your local distributor for service 3 4 6 3 3 Press Off key pad for 5 seconds and buzzer will sound twice 3 4 6 3 4 Turn Off the Breaker of Utility Input 3 4 6 3 5 The UPS lock problem is solved now but you shall contact with your Local distributor to make sure the error message shown is solved 3 5 8Shut Off 3 5 8 1 Press Off key pad for about 5 seconds the Inverter output will be turned off then the output load is supplied by Bypass loop and the LCD screen shows as drawing B 3 5 8 2 Turn Off the breaker of Utility Input 3 5 8 3 The UPS is turned off completely 4 Troubleshooting Guide 4 1 Trouble Shooting When the UPS malfunctions duri
23. shows the UPS is operated in normal mode V2 It shows the UPS is operated in Eco mode i O Fsg It shows the UPS is operated in CVCF 50Hz mode V4 It shows the UPS is operated in CVCF 60Hz mode 25 W It shows Output Voltage Adjustment from 0 to 3 or 0 to 3 X It shows UPS Identification Number Y It shows the UPS is in the No 1 of parallel systems 3 5 4 3 Press scroll up key pad you may execute special functions The Functions includes buzzer ON as drawing Q1 or buzzer OFF as drawing Q2 Alarm silence for UPS Warning and self test OFF As drawing R1 or self test ON as drawing R2 UPS will execute battery test for 10 seconds If the self test is successful it will show as Drawing E1 otherwise it will show as drawing E2 amp error message in the same time 3 5 5UPS Default Settings and their alternatives 3 5 5 1 Make sure the UPS is not On yet Press On Switch and scroll down G key pads simultaneously for approx 3 seconds the buzzer will sound twice the LCD display screen shows as drawing Q1 then the UPS is under setting mode now 3 5 5 2 To scroll down the LCD screen you may refer to Chapter 3 5 4 2 3 5 5 3 Except Buzzer as drawing Q1 amp Q2 and Self test as drawings R1 amp R2 all the rest default settings may be changed by pressing scroll up key pad 26 3 5 5 4 Drawings S1 and S2 mean the bypass input acceptable window it
24. t Circuit UPS Output Overloading Wrong Procedure to Enter Maintenance Mode 33 Output Parameters Set Error in Parallel System ID Numbers are in conflict in Parallel System or ID number Error in single unit Parallel communication error communication wire disconnected or failure to find ID1 UPS in parallel system CVCF mode with Bypass input The UPS must be operated in normal mode in parallel system eee Bypass Overload Time out and cut off output The settings of both control board and driver board are not matched each other Isolated Transformer Overheat Other Error code The specified modes include Normal mode ECO mode CVCF mode etc a a kd s D 2 2 2 2 2 2 2 2 2 Inverter Over current UPS Overheat 0 1 2 3 4 5 6 7 8 9 2 2 3 Panel explanation 2 3 2Rear Panel Explanation 2 3 1 Front Panel Function Explanations
25. tiwssesnasan riders terncsewoaeoieanandanedans 28 Trouble Soo espren E crudendestecennuusct decom scasones 28 Bundled Software Installation Guide 0 0 cece cece eee eeeeeeeeeeees 31 Hardware Ins alanOn osavcsacededawenewsswovbessdcowadarenmssaneciaesesdedssas 31 SOrware lastalla OMen a E EE NS 31 Customer Options SIGS ssa scetcxccawnsinnttanioneawsesandadaeddsasaanseieaeawsan 31 RZE 20d RS 22 32 Can cccsucecoctananieydecnseseuanroursahsstavicrivaserntiaak 31 RSE RS483 Cal Gas camer caescoteeocs aeons os onmiesiceena werner SEE EEES 31 SE CU SB O a a A AAN E 32 DCE Dry Contact B Cand ici cccrtacatcondceriidaaseiieeddareeewnsebedaan aes 32 SN MEC r E E E EEEE ETT 33 SEEE A a E E T E E TE 34 Important Safety Instruction 1 1 An Important Notice 1 1 1For parallel system installation please refer to parallel installation guide 1 1 2Because of LITTLE LEAKAGE CURRENTS generated by EMI Filter of the UPS it is necessary to double ensure if the earth of the UPS is properly grounded before AC mains is connected with 1 1 3To ensure safety in all applications where a UPS is hard wired to the Electrical Supply ensure that the system is installed by a Qualified Electrical Contractor 1 1 4The UPS has its own internal energy source battery Should the battery be switched on when no AC power is available there could be voltage at the output terminals 1 1 5Make sure that the AC Utility outlet is correctly grounded 1 1 6Do