1. In IL 21 Specifications 1 Device smartLAB scale 2 Max capacity 150 kg 330 lb 3 Units kg lb in 100 g 0 2 lb steps 4 Buttons Units 5 Battery 4 x AAA battenes 1 5 V 6 Size Lx Wx H 321 x 321 x 23 5 mm 8 Operating temperature 0 C 40 C 9 Storage temperature 20 C 60 C 10 Symbol when overburdened 11 Symbol for low batteries E 12 Communication Data transfer ANT and BLE wireless 7 Weight 1980 g without batteries Contents 1 smartLAB scale Bathroom Scale 1 User manual 4 1 5V AAA batteries General Information Please place the scale on an even flat and hard floor The floor is the basis for a correct measurement Soft surface such as carpet will affect the performance of the scale Measurement on a carpet can be enabled by the extension feet If possible please use the scale at the same time every day we recommend in the morning after having used the toilet with empty stomach and without clothes in order to be able to compare the results Please wait about 15 minutes after getting up before you measure your body weight so that the water of your body can disperse Please do not move during the measurement Please wait several hours before measuring after unaccustomed physical exercise Sauna or bath drinking and eating 22 The device is for your own use only and not for medical or commercial use Please note that technical related meas
2. appear on the LCD Display e Close the cover of the battery case and wait until the digits 0 0kg show on the display Note In case the scale does not operate please remove the batteries and insert them again A gt px Your smartLAB scale Bathroom Scale has a symbol indicating that the batteries need to be changed In case the batteries are almost empty the symbol E will show on the display The device will power of in 4 seconds You should change the batteries then Please remove the batteries in case you are not going to use the scale for one month or more in order to avoid an automatic discharge of the batteries The Bathroom Scale as well as the batteries must be disposed according to the local regulations In order to guarantee a correct measurement you should calibrate the scale always after any location change Just tip on the scale and wait until it shows 0 0 on the scale 24 Initial Start quick weighing Use the smartLAB scale Bathroom Scale to measure your weight Do not move stand still and stand on both legs The scale will turn on automatically when stepping on it The scale starts measuring immediately a beep tells amp you the end of the measurement and finally shows your body weight on the display Now you can step off the scale The scale will deactivate automatically after several seconds Start Measuring Select Measuring Unit With batteries correctly in
3. ase check the batteries before any complaint and change them if necessary Troubleshooting Error Prompt Overload The device will Stop using this scale for measure power off in four seconds ment The scale only weighs until 150kg Low Battery The device Replace all four batteries at the same will power off in four sec time Please purchase the authorized onds batteries for replacement 27 When Measuring Problem Root Gause sotanon Abnormal measur ing results Too high or Too low or Huge difference between two recent measurement No display on LCD when the device powers on The device powers off automatically Incorrect posture The device is located on a soft ground such as a carpet OR on a rugged surface Batteries not yet installed Worn batteries Low battery Please step on the platform and stand still Please place the device on a flat hard surface Install the batteries Please refer to Insert the batteries Replace all four batteries at the same time Please pur chase the authorized batteries for replacement Replace all four batteries at the same time Please pur chase the authorized batteries for replacement 28 Symbol Meaning The warning signs and symbols are essential to ensure your correct and safe use of this product and protect you and others from injury Please kindly find the meanings of the warning signs and symbols w
4. concerning the disposal of electrical and electronic devices a reprocessing and the collection points you can get from the local authorities waste disposal companies from retailers and manufacturers of the device RoHS compliance This product complies with Directive 2002 95 EC of the European Parlia ment and the Council of 27th January 2003 regarding the limited use of dangerous substances in electrical and electronic equipment RoHS and its variations 30 Warranty HMM Diagnostics GmbH products need to fulfill high quality requirements Because of this reason HMM Diagnostics GmbH gives a 2 year warranty by purchasing this smartLAB product You can even extend the warranty amp from 3 to 5 years without extra pay when you register your product Please 2 register online under following website www hmm info en registration 58 Wear parts batteries etc are excluded from warranty 31 Manufacturer HMM Diagnostics GmbH Friedrichstr 89 D 69221 Dossenheim Germany mail info hmm info www hmm info Weitere Informationen zu den smartLAB Produkten More information on our smartLAB products www smartlab org
5. hich you may encounter in the label and user manual as follows Symbol for THE OPERATION GUIDE MUST BE READ Symbol for COMPLIES WITH MDD93 42 ECC REQUIREMENTS Symbol for SE RIAL NUMBER Symbol for DIRECT CURRENT Symbol for MANUFAC TURER Symbol for MANUFACTURE DATE Symbol for ENVIRON MENT PROTECTION Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your local authority or retailer for recycling advice 29 WEEE note The WEEE Waste Electrical and Electronic Equipment Directive that came into effect as European law on 13th February 2003 led to a major change in the disposal of electrical equipment The primarily purpose of this directive is to prevent electronic waste WEEE while encouraging for reuse recycling and other forms of reprocessing to reduce waste The WEEE logo on the product and the packaging indicates that it is not allowed to dispose of the product in the ordinary household waste It is your responsibility to deliver all the disused electri cal and electronic equipment to the respective collection points A separate collection and proper recycling of electronic waste helps dealing economically with natural resources Furthermore the recycling of electrical waste is a contribution to the conservation of our environment and thus the health of all people More information
6. smartLAB scale Bathroom Scale User Manual Please read the user manual carefully before the first use HMM Diagnostics GmbH m Friedrichstra e 89 D 69221 Dossenheim Germany www hmm info Content I Introduction Principle of Measurement II Your smartLAB scale W Display amp functions Content General Information Security Information III Setup amp Operating functions Inserting and Changing the batteries Initial start quick weighing Start Measurement Optional Weighing on a carpet IV Miscellaneous Maintenance Troubleshooting Symbol Meaning Regularity and Safety Notice Warranty 24 24 25 25 26 27 27 27 29 30 31 19 I Introduction Thank you for choosing our smartLAB scale Bathroom Scale This product enables you to measure your body weight Please read the instructions carefully before you first use the scale and keep the instructions for a future use Principle of measurement Your smartLAB scale Bathroom Scale measures your body weight with the help of 4 high accurate sensores 20 II Your smartLAB scale General Instructions The smartLAB scale Bathroom Scale applies SENSE ON technology It s not necessary to turn on or turn off the scale just stand on the scale for measu rement It will turn on automatically when stepping on Display amp functions LCD Display Sensor Unit Button Battery Compartment LCD Display WA j a
7. stalled press the UNIT button on the back of the scale to select the measurement unit The default measurement unit is kg You may press UNIT button to choose among kilogram and pound mM By UU LIL Daily Measurement Thanks to the SENSE ON patent technology the scale will automatically turn on when you step on the platform Stand still and keep full contact with the scale until the LCD displays the weight and the unit stops blinking A beep will let you know when the weighing is done The scale will turn off automatically after a few seconds Optional Weighing on a carpet You can use the smartLAB scale with the extension feet on a carpet For this please follow these steps 1 Remove the non slip pads from 2 Fitthe extension feet firmly onto the scales feet the scales feet Now you can use the scale on a carpet 26 IV Miscellaneous Maintenance e Please clean your device regularly with a wet soft cloth Use a dry soft cloth to dry up the device Do not use caustic cleaning solutions Do not B amp put the device under fluent water HST19 e Protect the device from impacts humidity dust chemicals or fluctuations of temperature Do not store near heat sources such as ovens or heating installations e NEVER take the scale to pieces by yourself In this case the warranty will not be valid anymore Only the manufacturer or the authorized trader is allowed to repair the scale Ple
8. uring tolerances are possible since the scale is not especially made for professional medical use The smartLAB scale Bathroom Scale corresponds to the EC directive 89 336 Please feel free to contact the manufacturer or the customer service for more information Security information A A A A gt gt Avoid slippery floor such as tile floor Avoid using the device close to a microwave oven Please do not use the smartLAB scale Bathroom Scale with wet feet slip hazard Avoid measuring platform immediately after bath Do not swallow the batteries danger of life Please store batteries and Bathroom Scale at a place children cannot reach In case a battery has been swallowed please consult a physician immediately Keep children away from the packaging materials danger of asphyxiation Do not recharge the batteries Do not take them to pieces Do not throw them into a fire Do not short circuit them Avoid storage in following locations e Where there is water e Where the device may be exposed to extreme temperature humidity moisture direct sunlight dust or salt air e Where there is risk of shock or drop e Where you store chemicals or full of corrosive gasses 23 III Setup amp Operating functions Inserting and changing the batteries e Please open the cover of the battery case at the back of the device e Insert 4 AAA batteries 1 5 V Please pay attention to the polarity e The digits 8888 will