Home
Xterior 150W Tri Flood
Contents
1. USER MANUAL Xterior 150W Tri Flood Safety WARNING FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START UP CAUTION INPUT VOLTAGE OF 110 240V SAFETY INSTRUCTIONS Every person involved with the installation operation amp maintenance of this equipment should Be competent Follow the instructions of this manual CAUTION TAKE CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer and do not use the equipment To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written in this manual Please note that damages caused by user modifications to this equipment are not subject to warranty Xterior 150W Tri Flood Safety IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorised modification to the equipment e Never let the power cable come into contact with other cables Handle the power cable and all mains voltage connections with particular caution e Never remove warning or informative labels from the equipment e Do not open the equipment and do not modify the equipment e Do not connect this equipment to a dimmer pack e
2. cause serious damage to people and property Xterior 150W Tri Flood Introduction Introduction Xterior 150W Tri Flood 150W tri colour LED Beam angle 60 degrees e 400Hz refresh rate 0 100 dimming and variable strobe e DMX channels 3 5 or 6 selectable e Static colour colour fade colour change master slave and DMX modes e Optional I R remote LEDJ90B 4 push button menu with LCD diaplay e IP rated power in out sockets IP rated 3 pin DMX in out sockets Power consumption 186W e Power supply 100 240V 50 60Hz IP rating IP 65 11 Dimensions 320 x 180 x 325mm e Weight 8 6Kgs Overview Identification 1 Tightening Knobs 2 Bracket 3 Power in 4 DMX in 5 DMX out 6 Power out 7 Mode button 8 Enter button 9 Up button 10 Down button 11 LCD display Setup Operating Instructions The Xterior 150W Tri Flood is a DMX 512 controllable unit using a high efficiency COB LED and will operate in stand alone master slave or DMX control modes Xterior 150W Tri Flood Operation Xterior 150W Tri Flood Operation modes Built in programmes To activate the units built in programmes press the MODE button to show 01 STATIC on the LCD screen Press the ENTER button to choose between the 4 built in programmes by using the UP and DOWN buttons Now press the ENTER button to select the desired speed and adjust by using the UP and DOWN butto
3. Do not switch the equipment on and off in short intervals as this will reduce the system s life Do not expose to flammable sources or gases e Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable e Make sure that the available voltage is between 220v 240v e Make sure that the power cable is never crimped or damaged Check the equipment and the power cable periodically e If the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again e If your product fails to function correctly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Prolight dealer for service e Only use fuses of same type and rating e Repairs servicing and power connection must only be carried out by a qualified technician THIS UNIT CONTAINS NO USER SERVICEABLE PARTS e WARRANTY One year from date of purchase OPERATING DETERMINATIONS If this equipment is operated in any other way than those described in this manual the product may suffer damage and the warranty becomes void Incorrect operation may lead to danger e g short circuit burns electric shocks lamp failure etc Do not endanger your own safety and the safety of others Incorrect installation or use can
4. g the UP and DOWN buttons For the 3 5 or 6 channel DMX address information please see page 5 Slave mode To activate the unit in slave mode first you must link multiple units together and press the MODE button to show SLAVE MODE on the LCD screen Now on the master unit press the MODE button to select the desired mode and the slave units will now run in sequence with the master unit NOTE The unit has a password and locks after being unused for several minutes to unlock the unit again press the buttons in the following order UP DOWN UP DOWN followed by ENTER ji Xterior 150W Tri Flood DMX Programme Charts Xterior 150W Tri DMX Charts 3 channel mode DMX chart Valu 0 255 Function Red 0 100 Green 0 100 0 255 Blue 0 100 5 channel mode DMX chart vato Function 0 255 0 255 Green 0 255 Blue 0 255 Master dimmer 0 100 O O ES 1 5 6 10 11 255 Strobe slow to fast 6 channel mode DMX chart Value Function O 0 255 Master dimmer 0 100 0 255 Strobe slow to fast 0 255 0 255 0 4 On 5 125 Colour change slow to fast 126 255 Colour fade slow to fast Xterior 150W Tri Flood DMX Set up DMX Linking e DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure prope
5. ns Press the ENTER button once more to select the desired flash value and adjust by using the UP and DOWN buttons Speed values 00 99 00 slow 99 fast Flash values 00 99 00 slow 99 fast Programme 1 Static colour In this mode you can set the Xterior 150W Tri to any colour and any brightness When you are in the 01 STATIC mode press the enter button to change the brightness of each individual colour The R represents Red G Green B Blue and F strobe The two digits after it are the brightness 00 to 99 or in CF they are the strobe speed Example If you set R G and B all to zero the 150W Tri will have no LEDs showing blackout If you set R to 99 and G and B to zero the 150W Tri will be 100 Red Programme 2 7 colour change In this mode the Xterior 150W Tri will run through its 7 preset colours Programme 3 3 colour change In this mode the Xterior 150W Tri will run through its 3 colours Programme 4 colour fade In this mode the Xterior 150W Tri will fade through its 7 preset colours DMX mode To activate the unit in DMX mode press the MODE button to show DMX MODE on the LCD screen Press the ENTER button and select the desired DMX address setting by using the UP and DOWN buttons Then to select one of the 3 DMX modes 3 5 or 6 channel press the ENTER button again to choose the desired DMX mode by usin
6. r DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain DATA Cable DMX cable requirements for DMX operation e The Xterior 150W Tri can be controlled via DMX 512 protocol The DMX address is set on the back of the unit Your unit requires a IP rated connector for data input output Notice e Be sure to follow figures 2 8 3 when making your own cables Do not connect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behaviour common DMX 512 out 1 1 DMX 512 in ii 30 DMX 03 i 3 pin XLR 3 pin XLR 2 DMX 02 i XLR MALE SOCKET XLR FEMALE SOCKET XLR Pin Configuration A Termination reduces signal transmission problems 2 cold 1 ground i A and interferance it is always advisable to connect a 1 ground 2 cold Pin 1 Ground DMX terminal resistance 120 Ohm 1 4 W between 7 pin 2 DMX and pin 3 DMX of
7. the last fixture i Pin 2 Negative AOL 3Hot Pin 3 Postive fig 3 Special Note Line termination e When longer runs of cable are used you may need to use a terminator on the last unit to avoid erratic behaviour fig 4 fig 4 Using a cable terminator part number LEDJ260 will decrease the possibilities of erratic behaviour 5 Pin XLR DMX Connectors e Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 Pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The chart below details the correct cable conversion 5 Pin XLR socket Pin a GND screen 9 3 Pin XLR socket Pin 1 GND sereen Pin 2 Signal Pin 3 Signal 3 Pin XLR socket Pin 1 GND screen Pin 2 Signal ON Pin 3 Signal 5 Pin XLR socket Pin 1 Sana Pin 2 Si Al u Si anal A pin 5 Ne WWW PROLIGHT CO UK
Download Pdf Manuals
Related Search
Related Contents
launcher progressive nitrous controller Philips SHAVER 9000 SensoTouch 3D RQ1280 BーBー`LAB janv-Mars 09. - Office de Tourisme W317-IT1-03+CPM1A+OperManual Atmel ATA6264 Power Supply User Manual Manuel d`utilisation - Sena Technologies, Inc. METEO - parapente cote d`azur ascendance 06 manuale di installazione uso e manutenzione manual de instalación Télécharger fanzine n°2 - aarrg Copyright © All rights reserved.