Home
        User manual
         Contents
1.  CTEK  produces very high quality voltage and current with low ripple         IP44 cannot be guaranteed if the charger is not positioned horizontally with the long side or top side turned up     MAINTENANCE   The charger is maintenance free  The charger must not be opened  doing so will invalidate the warranty  If the power cable is  damaged it must be replaced by CTEK or its authorized representative  The charger casing can be cleaned using a damp cloth and  mild cleaning agent  Remove the plug from the power socket before cleaning     LIMITED WARRANTY   CTEK SWEDEN AB  Rostugnsv  3  SE 776 70 VIKMANSHYTTAN  SWEDEN issues this limited warranty to the original purchaser  of this product  This limited warranty is not transferable  CTEK SWEDEN AB warrants this unit for two years from the date of  purchase against defect workmanship or material  It is the obligation of the purchaser to forward the unit together with proof of pur   chase to the manufacturer or its representative with transportation cost prepaid  This warranty is void if the unit is abused  handled  carelessly or repaired by anyone other than CTEK SWEDEN AB or its authorized representative  CTEK SWEDEN AB makes no  warranty other than this limited warranty and expressly excludes any implied warranty including any warranty for consequential  damages  This is the only expressed limited warranty and CTEK SWEDEN AB neither assumes nor authorizes anyone to assume  or make any other obligation towards the product other 
2.  The temperature is best measured on or very close to the battery  Therefore always place the sensor as close to the battery as  possible when charging  The sensor cable could be prolonged or cut to length with the same functionality  A short circuited or  disconnected sensor is indicated by lamp A  The charging voltage is then adjusted to the  25  C condition     SPECIFICATION                   MULTI XS 25000 MULTI XT 14000  XS 25000 XT 14000  Voltage AC 170 260VAC  50 60Hz   Charging voltage 14 4V 28 8V  Charging current 25A max  14A max        Current  mains    2 9A rms  at full charging current        Back Current Drain      lt 2Ah per month       Current ripple       lt 4                                   Ambient temperature  20  C to  50  C Output power is automatically reduced at higher temperatures    Cooling Fan   Charger type Eight step  fully automatic   Battery types All types of 12V lead acid batteries All types of 24V lead acid batteries   WET  MF  AGM and GEL    WET  MF  AGM and GEL     Battery capacity 50 500Ah 28 300Ah  up to 500Ah maintenance   Protection class IP44  Outdoor use       Weight 1 9kg          Back current drain is the current that the charger drains from the battery if the AC cord is disconnected        The quality of the charging voltage and charging current are very important  High current ripple heats the battery and ages  the positive electrode  High voltage ripple can damage other equipment connected to batteries  The battery chargers from
3.  level  During this phase the current tapers suc   cessively  Once the current has tapered to the set limit  this phase switches to being timed  If the total time for Absorption exceeds  the time limit the charger automatically switches to maintenance    Analysis  Lamp 3    Testing self discharge  If self discharge is too high  charging is discontinued and fault mode is indicated    Maintenance charging   Float  Lamp 4    Charging at constant voltage     Maintenance charging   Pulse  Lamp 4    State of charge varies between 95  and 100   The battery receives a pulse when the voltage drops and keeps the battery in  perfect condition when it is not in use  The charger can be connected for months at a time  The charger continuously measures  the terminal voltage to determine whether a charging pulse should be initiated  If the battery is loaded and or the battery   s terminal  voltage drops the charger starts a charging pulse until the terminal voltage reaches the set level  The charging pulse is then  discontinued and the cycle is repeated infinitely  If the terminal voltage drops below a lower limit  the charger automatically goes  back to the beginning of the charging curve     GB   3    Recond  Lamp 5   only on MULTI XS 25000 and MULTI XT 14000    This mode is used to recover deeply discharged flooded batteries  Recondition of deep discharged batteries  The voltage  increases with reduced current for a limited time period  The higher voltage starts some gassing and mixing of
4.  the acid  which is  beneficial for both battery capacity and expected life  Note that the battery could emit explosive gas during Recond  Recond is  performed between Analysis and Maintenance     INDICATORS       Lamp Description  Fault mode  the charging is discontinued  For fault causes  see below   Start mode    0  1  2 Bulk charging   3 Absorption charging   4 Maintenance charging   5 Supply  Only on MULTI XS 25000 and MULTI XT 14000    6 Recond reconditioning of completely discharged batteries   Only on MULTI XS 25000 and MULTI XT 14000   A   B   C   D    Charging without temperature compensation    Mains voltage connected   Normal  Only on MULTI XS 25000 and MULTI XT 14000    Supply  Only on MULTI XS 25000 and MULTI XT 14000   E Recond  Only on MULTI XS 25000 and MULTI XT 14000     Fault mode   The charger goes to fault mode in the following situations      The battery is connected with poles reversed to the charger s terminals        The charger   s analysis function has interrupted charging        The terminals on the charger are short circuited after charging has started       The charger has been in start mode for more than 4 hours     TEMPERATURE COMPENSATION   MULTI XS 25000  XS 25000  MULTI XT 14000 and XT 14000 have a sensor cable placed together with the battery cables  The  units will automatically adjust the charging voltage if the temperature deviates from  25  C  A high temperature lowers the voltage  and freezing conditions is handled by higher voltage   
5.  the chassis   The negative terminal is normally the grounded post   3  Charging a negatively grounded battery  Connect the red cable to the positive terminal on the battery and the black cable to  good metal engine ground away from the battery  Ensure you do not connect the black cable to fuel lines or sheet metal body  parts    4  Charging a positively grounded battery  Connect the black cable to the negative terminal on the battery and the red cable to  good metal engine ground away from the battery  Ensure you do not connect the red cable to fuel lines or sheet metal body parts           Connecting the charger to an out of vehicle battery    1  The power cord should be disconnected when connecting or disconnecting the battery leads    2  Connect the red cable to the positive terminal on the battery and the black cable to the negative terminal    If the battery leads have been connected incorrectly  the reverse polarity protection system will ensure that neither the charger nor  the battery are damaged     Start charging   1  Connect the chargers AC cord to an AC Power Supply  The charger will indicate POWER  yellow indication lamp  B     2  The lamp for completely discharged battery  1  will illuminate if the battery s voltage is less than 12V for MULTI XS 25000 and  XS 25000 or 24V for MULTI XT 14000 or XT 14000    3  Normal charging will be indicated by the following lights  completely discharged battery  1   bulk charging  2   absorption  charging  3  or maintenance ch
6. 000 are programmed according to    PROGRAM DESCRIPTION    with fixed settings  MULTI XS 2500 and  MULTI XT 14000 can easily be set for different types of batteries or conditions  The following recommendations should  however   only be seen as guidelines  Please consult the battery manufacturer for further instructions    Settings are made by pressing the    MODE button     and stepping forward one press at a time until the required mode is reached   the button is then released  After about 2 seconds the charger activates the selected mode  The selected mode is saved in a  memory in the charger and remains there even if the charger is disconnected from battery and mains        NORMAL   Normal setting for wet batteries  maintenance free and for most Gel batteries  Some Gel batteries    NORMAL prefer a slightly lower charging voltage  Please consult the battery manufacturer when in doubt        SUPPLY SUPPLY   The charger operates at a constant voltage  This is the maintenance mode for applications where  maximum capacity from the battery is important  like floor sweepers and golf carts  Note that the Spark  protection function is suppressed in this mode           RECOND   This mode is used to recover deep discharged flooded batteries where you could expect a  stratified acid  high acid weight in the bottom  low on top   Check with battery manufacturer when in doubt   Use this mode with care  because the high voltage will cause some water loss  16V is normally no problem for  el
7. CCTEK     gt     Battery Charger    MULTI XS 25000  XS 25000  MULTI XT 14000  XT 14000    For lead acid batteries       User Manual and Guide to professional  charging of starter and deep cycle batteries     INTRODUCTION   Congratulations on purchasing your new CTEK professional switch mode battery charger  This charger is part of a range of profes   sional battery chargers from CTEK SWEDEN AB  It represents the latest technology in battery charging with charging and analysis  in eight steps with temperature compensation  Read this User Manual and follow the instructions carefully before using your  new charger     SAFETY    The charger is designed for lead acid batteries  Do not use the charger for any other purpose   Use safety glasses and turn your head away when connecting or disconnecting a battery    Battery acid is corrosive  Rinse immediately with water if acid comes into contact with skin or eyes  Seek medical advice    Make sure that the cable is not pinched or in contact with warm surfaces or sharp edges    While charging  a battery can emit explosive gases  so it is important to avoid sparks in the immediate area    Always provide for proper ventilation during charging    Avoid covering the charger    Make sure that the electrical cable does not come into contact with water    Never charge a frozen battery    Never charge a damaged battery    Do not place the charger on the battery while charging    The electrical connection must fulfil the national heavy current 
8. NORMAL   YES Max 14A for 4h until the   14A for max 20h  28 8V until 4h after the  or voltage reaches 25 2V  current dropped to 2 5A   max 12h   RECOND      SUPPLY      XT 14000    MODE Desulphation Soft Start Bulk Absorption  Pa PRESET   YES Max 14A for 4h until the   14A for max 20h  28 8V until 4h after the  a        6   GB             voltage reaches 25 2V        current dropped to 2 5A   max 12h                                Analysis Recond Float Pulse  To o oo         Tests whether the Maintenance for Maintenance for    Reconditioning of                                                   battery retains   maximum maximum  a drained battery i  the energy performance battery life   Analysis Recond Float Pulse  Warning indication if Max 15 8V and 3A for 13 6V with max 25A for Pulse start at 12 9V  max  voltage drops to 12 0Vin   4h for deeply discharged   max 10 days  voltage 14 4V    3 minutes  batteries  Otherwise  for 30 minutes  only in  Recond mode    13 6V max 25A    Analysis Recond Float Pulse  Warning indication if 13 6V with max 25A for Pulse start at 12 9V  max  voltage drops to 12 0V in max 10 days  voltage 14 4V    3 minutes    Analysis Recond Float Pulse  Warning indication if Max 31 6V and 1 7A for 27 2V with max 14A for Pulse start at 25 8V  max  voltage drops to 24 0Vin   4h for deeply discharged   max 10 days  voltage 28 8V    3 minutes  batteries  Otherwise  for 30 minutes  only in  Recond mode    27 2V max 14A    Analysis Recond Float Pulse  Warning indi
9. arging  4   When the maintenance charging lamp illuminates the battery is fully charged  Charging  will start if the voltage drops  The charger can normally be connected for months  Reconditioning  only on MULTI XS 25000 and  MULTI XT 14000  is indicated by the lamp  5  illuminating    4  If the battery leads have been connected incorrectly  the reverse polarity protection system will ensure that neither the charger  nor the battery are damaged    5  If nothing happens  If the lamp indicating the setting and the power lamp remain lit but no other lamp illuminates  the connection  to the battery or chassis may be poor or the battery may be faulty  Another cause may be a lack of voltage in the AC Power Supply   Begin by improving the connection between the battery and charger     2   GB    6  Charging can be stopped at any time by disconnecting the charger   s AC cord  Always disconnect the AC cord before  disconnecting the battery leads  When you stop charging a battery installed in a vehicle you should always disconnect the battery  lead from the chassis before disconnecting the other battery lead     IMPORTANT INFORMATION FOR MULTI XT 14000 AND XT 14000   Please note that the battery pack in the 24V system in most cases consists of more than one battery  They are linked up to the  24V system  but the individual batteries generally have a lower voltage  Therefore it is important for the charger to be connected  correctly     BATTERY TYPES AND SETTINGS   The XS 25000 and XT 14
10. cation if 27 2V with max 14A for Pulse start at 25 8V  max  voltage drops to 24 0V in max 10 days  voltage 28 8V     3 minutes              GB     7    CCTEIK7 gt     THE SMARTEST BATTERY CHARGERS IN THE WORLD    
11. ectronics in 12V system  or 32V in 24V system  Consult your supplier when in doubt  Life of light bulbs will  be reduced at higher voltage  Try to disconnect light from the battery during this phase  Maximum effect and  minimum risk for electronics is achieved by charging a disconnected battery     CHARGING PHASES  MULTI XS 25000  XS 25000  MULTI XT 14000 and XT 14000 charges and analyses in eight fully automatic steps   MULTI XS 25000 and MULTI XT 14000 have three different operating modes  see Battery Types and Settings     The battery charger has an 8 step fully automatic charging cycle     Desulphation  Desulphation with pulses recovers sulphated batteries  Indicates with lamp 1     Soft start  Lamp 1    Start mode for the charging cycle  The start phase continues until the battery s terminal voltage has risen above the set limit  at  which point the charger switches to bulk charging  If the terminal voltage has not passed the voltage limit within the time limit  the  charger switches to fault mode  lamp 0  and discontinues the charging  If so  the battery is faulty or its capacity is too large     Bulk  Lamp 2   Main charge when 80  of charging takes place  The charger delivers maximum current until the terminal voltage has risen to the  set level  Bulk has a maximum time  at which point the charger automatically switches to Absorption     RECOND                      Absorption  Lamp 3    Complete charge up to virtually 100   The terminal voltage is maintained at the set
12. requirements    Check the charger cabling before use  Make sure there are no cracks in the cabling or in the protective covering  A charger with  damaged cables may not be used    Always check that the charger has gone over to maintenance charging mode before leaving the charger unattended and  connected for long periods  If the charger had not gone over to maintenance charging within 3 days  this is an indication of a  problem  In this case the charger must be disconnected manually    All batteries fail sooner or later  A battery that fails during charging is normally taken care of by the chargers advanced control   but certain uncommon errors in the battery can still arise  Don   t leave the battery charger unattended for a longer period of time   Only mount the charger on a flat surface    This equipment may not be used by children or by those who can not read and understand the manual if they are not supervised  by a responsible person who can guarantee that the battery charger is being used in a safe manner  Store and use the battery  charger out of the reach of children  Make sure that children do not play with the battery charger        When using outdoors the charger has to be positioned horizontally with the long side or top side turned up     CHARGING   Connecting the charger to a battery fitted in a vehicle   1  The power cord should be disconnected when connecting or disconnecting the battery leads    2  Identify the battery terminal that is grounded  connected to
13. than this limited warranty     DECLARATION OF CONFORMITY   CTEK SWEDEN AB hereby declares under sole responsibility that the MULTI XS 25000  XS 25000  MULTI XT 14000 and   XT 14000 battery chargers  to which this declaration relates  conforms with the following standards  EN60335 1  EN60335 2 29  following the provisions of directive 73 23 EEC amended by 93 68 EEC and EN61000 3 3  EN61000 3 2  EN55014 1  EN55014 2   55011 following the provisions of directive 89 336 EEC amended by 92 31 EEC and 93 68 EEC     Vikmanshyttan Sweden  01 01 2006   B  rje Maleus  Managing Director  CTEK SWEDEN AB  CTEK SWEDEN AB   Rostugnsvagen 3   SE 776 70 VIKMANSHYTTAN   www ctek com    GB  5                 PROGRAM DESCRIPTION                                                                         Desulphation Soft Start Bulk Absorption  So  Al  S    D          So  D  gt  Recovers a Tests the battery Peak charge with      i Bulk charge ya    5 sulphated battery condition minimal fluid loss  a  E                o     5  oO  MULTI XS 25000  MODE Desulphation Soft Start Bulk Absorption  NORMAL   YES Max 25A for 4h until the   25A for max 20h  14 4V until after the  or voltage reaches 12 6V  current dropped to 4 5A   max 12h   RECOND  SUPPLY  XS 25000  MODE Desulphation Soft Start Bulk Absorption  PRESET   YES Max 25A for 4h until the   25A for max 20h  14 4V until 4h after the  voltage reaches 12 6V  current dropped to 4 5A   max 12h   MULTI XT 14000  MODE Desulphation Soft Start Bulk Absorption  
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
SD3D Media Generator Software User Manual  manual caf 5 2011    取扱説明書 - 丸茂電機  Ergotron WorkFit-C, Single LD Sit-Stand Workstation  DELL 1610HD  Castelle UF-490 User's Manual  User guide  利用規約(PDF)      Copyright © All rights reserved. 
   Failed to retrieve file