294000.10063 Hoyer Ascend (A5).indd
Contents
1. 10063 Rev A English Poya Ascend 1 The Hoyer Ascend Patient Lift Push Handle Spreader Bar Cow horns Battery Control Pack Spreader Bar Attachment Hook Mast Extrusion Rear Castor braked Front Castor non braked 3 294000 10063 Rev A Hoyer English Ascend 2 Introduction About Your Lift The Hoyer Ascend is an electrically operated patient lift Each Ascend lift is fully assembled load tested and certified before being packed shipped The packing consists of a strong purpose built carton that is used for both export and domestic markets to ensure the safe arrival of the lift A number of documents are supplied in a wallet and packed with each lift and should be kept safely for future reference e TEST CERTIFICATE e USER MANUAL e DEALER GUARANTEE CARD Europe only CUSTOMER SATISFACTION CARD Europe only e PACKING CHECK LIST The TEST CERTIFICATE is an important document and will be required for your insurance records It is valid for six months and after it has expired the lift should be inspected and serviced per the maintenance schedule Servicing and periodic testing can be carried out by your authorized supplier Please ensure your lift is included in their maintenance schedule If you are at all unsure what your local market servicing requirements are please check with your dealer and or a local government agency The Hoyer Ascend is suitable for the followi
2. Check the attachment of the boom to the mast Make sure there is only minimal side movement of the boom and the boom is free to rotate VY VY v on the boom bearing 2 MAST Check the operation of the mast locking device Make sure the J hk mast fully engages into the socket Check the bottom actuator 3 ACTUATOR The actuator should require no maintenance other than x v checking for correct operation and listening for unusual noise 4 POWER PACK Check the function of the emergency stop button and emergency lower Note The MINIMUM load required to manually lower vo vv the hoist using the emergency lower function is 30 kg 5 BATTERIES The batteries are housed in the power pack and should not require maintenance other than the regular charging as detailed in the y charging instructions Check that the connections remain clean 6 LEG ADJUSTMENT Check the legs operate in both full extensions yivivy inward outward 7 CASTORS Check all castors for firm attachment to the legs yviviv Check for free rotation of the castor and the wheels 8 CLEANING Clean with ordinary soap and water and or any hard surface disinfectant Harsh chemical cleaners or abrasives should be avoided as x v these may damage the surface finish of the lift Avoid wetting any of the electrical parts 9 LOAD TEST The load test should be carried out in accordance with the manufacturer s test procedures It is strongly recommended the testing is X carried o
3. down function is 30 kg 7 Batteries The batteries are protected from deep discharge by a LOW VOLTAGE ALARM This will sound when the batteries need recharging and the handcontrol is being operated It will not sound independently of the handcontrol being operated DO NOT IGNORE THIS WARNING ALARM Complete the lifting operation and place the battery on charge see charging instructions 8 Slings The Hoyer Ascend is suitable for patients in the SITTING position The slings suitable for this device are listed as follows e Hoyer Transport e Hoyer Standing 9 Knee pad adjustment The Ascend has an adjustable kneepad The range of travel is 6 inches Adjustment is achieved by loosening the knob located on the left hand side of the pad so to loosen the assembly enough to move the knee pad in either the upward or downward position 10 Removable footplate The Ascend has a removable footplate To remove the foot plate move to the front of the product and lift the footplate upward from the middle of the assemble NOTE Be careful when lifting the foot plate from its low seated position 14 294000 10063 Rev A English Hayer Ascend 8 Charging Instructions The batteries are located in the power pack and are charged via an off board desktop charger unit Hand Control Legs Open Close Boom Raise Lower Control Box Emergency Stop Raise Lower When the battery pack needs charging it is removed from the lift and fitt
4. Hoyer Hoyer Ascend User Instruction Manual amp Warranty To avoid injury read user manual prior to use Hoyer Ascend Manuel de l utilisateur et garantie Afin d viter tout accident veuillez lire attentivement la notice avant utilisation Hoyer Ascend Manual de Instrucciones y Garantia para el Usuario Para evitar posibles da os lea previamente el manual de usuario Hoyer Ascend Benutzerhandbuch und Garantie Um Verletzungen zu vermeiden lesen Sie bitte die Gebrauchsanweisung vor der ersten Benutzung mmJoerns WWHealthcare m Redefining patient handling Hoyer English Ascend Manufacturer s Contact Details Hoyer USA Joerns Healthcare Inc 2100 Design Road Suite 100 Arlington TX 76014 USA Tel 800 826 0270 Fax 800 457 8827 www joerns com Contents 1 Hoyer Ascend Patient Lifts EEE ENEE EEE AEAEE 3 2 Introduction About Your Lift sseni hierniana 4 3 Assembly and Commissioning Instructions ccccceceecesceceeeeeeeeeeeeeeeeeeeeeeeeeeeeteeeneneeas 5 Ee EC 9 5 Lifting with the Hoyer ASC nd nncsenarnonene aunta nonias aa 10 6 Safety Precautions zeegt EENEG mice cane 11 7 Operating Instructions 13 Be 1ce ale Hl ete TC rt eters a E e 15 9 Maintenance Schedule amp Daily Check List cceeeeseeeeeseeeeeeneeeeeesseeeeteneneeteeesatens 17 10 Technical Specifications acncacwadniicannsnedoietiaunincniinninninnnaddenuin 19 K Wealth nt E 21 2 294000
5. Joerns Healthcare recommends that slings be checked regularly and particularly before use for signs of fraying or damage DO NOT use slings that are worn or damaged e HOYER RECOMMENDS THE USE OF GENUINE HOYER PARTS Hoyer slings and lifters are not designed to be interchangeable with other manufacturer s products Using other manufacturer s products on Hoyer products is potentially unsafe and could result in serious injury to patient and or caregiver e Refer to maximum weight capacity of lift Sling capacity is limited by the maximum capacity of the lift 12 294000 10063 Rev A English Hayer Ascend 7 Operating Instructions OPERATING CONTROLS Emergency Stop Detachable Battery Button Pack Emergency Lower Raise Hand Control Actuator Motor Battery Indicator 1 Leg adjustment The legs on the Hoyer Ascend are electrically adjustable for width The legs can be opened to enable access around armchairs or wheelchairs For transferring and negotiating narrow doorways and passages the lift legs should be in the closed position Electric leg adjustment is achieved by pressing the appropriate buttons on the handcontrol The legs will be locked whenever the handcontrol switch is released 2 Castors and Braking The lift has two braked castors which can be applied for parking When lifting the castors should be left free and un braked The lift will then be able to move to the center of gravity o
6. Place the battery on charge whenever it is not in use If it is more convenient to do so place on charge every night The charger will not allow the batteries to overcharge A WARNING NEVER run the batteries completely flat As soon as the audible warning sounds complete the lifting operation in hand and place on charge A CAUTION NEVER store the power pack for long periods without regular charging throughout the storage period A WARNING ALWAYS make sure the mains power to the charger is switched off before connecting or disconnecting the power pack A WARNING NEVER leave the power pack plugged in to the charger with the mains power off A WARNING Do not charge an electric lift in a bathroom or shower room 16 294000 10063 Rev A English eer Ascend 9 Maintenance Schedule amp Daily Check List All Hoyer products are designed for minimum maintenance however some safety checks and procedures are required A schedule of DAILY tasks are detailed below Daily checks and a six monthly service inspection and test will ensure a lift is kept in optimum safe working condition A list of spare parts is available upon request The LOAD TEST and certification should only be carried out by qualified personnel or an authorized service agent dealer DAILY CHECK LIST Joerns Healthcare strongly recommends the following checks be carried out on a daily basis and before using lift e MAKE sure the lift moves freely on its
7. by the label on the side of the mast The electric leg operation will not function unless the mast is fully engaged 6 294000 10063 Rev A English eye Ascend 4 Turn the locking knob until hand tight 5 Line the handle assembly up to the mast and attach using the fixings provided The fixings and wrench needed to attached the handle are kept in the user instruction wallet for safe keeping 6 Fit power pack to the lift and make sure the latch holding the pack in place is fully engaged Click in place DISASSEMBLY The lift should not be disassembled unless for service repair or transport if necessary Therefore follow the assembly instructions in reverse sequence 7 294000 10063 Rev A Hoyer English Ascend ALWAYS CHECK THE FOLLOWING BEFORE OPERATION The mast is fully locked into position L s e The legs of the lift open and close satisfactorily This is done via the hand control The red emergency stop button located on the rear of the control box is in the OFF out position e M M 8 294000 10063 Rev A English Hayer Ascend 4 Sling Guide The Hoyer Ascend is suitable for patients in the SITTING position The slings suitable for this device are listed as follows e Hoyer Transport e Hoyer Standing USER GUIDE FOR STANDAID SLINGS The Transport and Standing sling is an easy fit sling suitable for standing and supporting It is not a general purpose
8. can dispatch authorized technicians This warranty is extended to the original purchaser of the equipment 21 294000 10063 Rev A ER Joerns BYWHealthcare Joerns Healthcare Inc 2100 Design Road Suite 100 Arlington TX 76014 USA Tel 800 826 0270 Fax 800 457 8827 www joerns com 2011 Joerns Healthcare 294000 10063 Rev A DCO 11 0339
9. castors e EXAMINE the spreader bar cow horns is firmly attached to the boom e EXAMINE the sling hooks and attachment clips on the spreader bar and boom for excessive wear e MAKE sure the legs open and close correctly OPERATE the hand control to confirm the boom raises and lowers satisfactorily e ON electric powered lifts check the operation of the emergency stop button EXAMINE slings for fraying or other damage DO NOT use any sling if damaged or if the sling shows signs of wear e CONFIRM the lift is not giving a low battery alarm when the hand control is operated If the alarm sounds DO NOT use and place on charge immediately MAINTENANCE INSPECTION AND TEST Joerns Healthcare recommend a thorough inspection and test of the Hoyer Ascend lift and lifting accessories slings scales etc is carried out on a regular basis Inspection frequency varies depending on locality so you must check with your dealer or local government agency as appropriate regarding_ how often an inspection is required The examination and test should be conducted according to the recommendations and procedures provided in this manual Joerns Healthcare recommends maintenance inspection and certified testing is carried out by authorized service agent dealers only 17 294000 10063 Rev A Hoyer English Ascend THESE CHECKS SHOULD INCLUDE g x gt 2 v Required X Recommended g 8 S 6 months in North America z S 52 1 BOOM
10. ed to an off board charging unit 1 Remove the power pack from the lift The pack is retained by a simple latch at the top of the power pack Lift the latch and the power pack will be released 2 Fit the power pack to the charging unit The location and latching of the power pack to the charger is the same system as used on the lift 3 Plug the charger mains plug into a suitable mains outlet 4 Charging is automatic and will fully charge the batteries over a period of eight to twelve hours Note Even if the charger is left plugged in for extended periods it will not allow the batteries to overcharge a Green Light Indicates main power is on b Yellow Light Indicates battery is charging c Battery will be fully charged when yellow light goes off Note Charging will take up to 4 hours It is recommended that the battery be charged immediately up on receipt 5 To return the lift to service disconnect power supply remove the power pack from the charger Fit the power pack to the lift and make sure the latch holding the pack in place is fully engaged Click in place The charging of Hoyer electric lifts is simple and straightfor ward but it is important to follow the charging instructions closely Please pay particular attention to the following warnings they will help you avoid problems with discharged batteries 45 294000 10063 Rev A Hoyer English Ascend A WARNING KEEP the batteries fully charged
11. f the lift If the brakes are applied it is the patient that will swing to the center of gravity and this may prove disconcerting and uncomfortable 3 Raising and lowering the boom The movement of the boom is achieved by a powerful electric actuator which is controlled by a simple hand control unit The handcontrol has two buttons with directional arrows UP and DOWN AV The actuator stops automatically at the limit of travel in both directions The handcontrol plugs into a socket at the base of the control box 13 294000 10063 Rev A Hoyer English Ascend 4 Emergency Stop The red Emergency Stop Button is located on the front of the control box and is activated by pressing in This will cut all power to the lift and only be reset by twisting the button anticlockwise and releasing 5 Electrical Emergency Down Up Emergency lower down and raise up buttons are provided at the front of the control box This is operated by inserting a ballpoint pen into the button highlighted Aw This will bring the boom up or down should the handcontrol fail at any time 6 Mechanical Emergency Down In the case of a complete electrical failure the electrical actuator is fitted with mechanical lowering device RED BOSS This will only operate when the lift is under load The device must be pulled upwards to activate and a slow decent will commence Note The MINIMUM load required to manually lower the hoist using the mechanical emergency
12. hanical components on lifts are covered under war ranty for a period of five 5 years from the date of delivery Damage caused by use in unsuitable environmental conditions or failure to maintain the product in accordance with user and service instructions in not covered Any alteration modification or repair unless performed by or authorized in writing by Joerns Healthcare will void this warranty Parts HoyerPro lifts contain various parts that wear from normal use These parts such as DC batteries and casters are not covered under the two year warranty but are covered for 90 days after date of delivery Joerns Healthcare s obligation under this warranty is limited to supplying replacement parts servic ing or replacing at its option any product which is found by Joerns Healthcare to be defective Warranty replacement parts are covered by the terms of this warranty until the product s original warranty period expires When requested by Joerns Healthcare parts must be returned for inspection at the customer s expense Credit will be issued only after inspection Service Most service requests handled by the facility Maintenance Department with assistance from the Joerns Healthcare Product Service Department Most parts requested can be shipped next day air at the customer s expense Should a technician be required one will be provided by Joerns Healthcare at our discretion Only the Joerns Healthcare Product Service Department
13. n Always let the lift find the correct center of gravity e DO NOT attempt to manoeuvre the lift by pushing on the mast boom or patient e ALWAYS manoeuvre the lift with the handle foot push pad provided e ALWAYS lower the patient to the lowest comfortable position before transfers e DO NOT push a loaded lift at speeds which exceed a slow walking pace 3 Km hour 0 8 metres second 11 294000 10063 Rev A Hoyer English Ascend e DO NOT push the lift over uneven or rough ground Particularly if loaded e DO NOT attempt to push pull a loaded lift over a floor obstruction e NEVER force an operating safety control All controls are easy to use and do not require excessive force The MINIMUM load required to manually lower the hoist using the mechanical emergency down function is 30 kg e DO NOT park a loaded lift on ANY sloping surface e DO NOT use electric lifts in a shower e DO NOT charge an electric lift in a bathroom or shower room e DO NOT lift a patient unless you are trained and competent to do so e YOUR lift is for patient lifting DO NOT use it or allow it to be used for any other purpose e DO NOT bump the lift down steps loaded or unloaded e DO NOT attempt to negotiate a loaded lift on a slope which exceeds 1 12 approximately 5 degrees e DO NOT attempt to negotiate a slope without a second helper being present e DO NOT use in a wet or corrosive environment such as poolside locations e
14. ng Attachment Loop Straps Chest Support Place the sling down behind patient s back between base of shoulder blades and bottom of rib cage Attach the support straps around the front of the patient This strap need not be tight It is there to hold the sling in position whilst attaching the sling to the Standaid It may be left off altogether if preferred Ensure that the patient s arms are outside the sling NOTE For detailed fitting instructions please refer to the user guide supplied with each sling AWARNING Joerns Healthcare recommends that slings be checked regularly and particularly before use for signs of fraying or damage DO NOT use slings that are worn or damaged AWARNING HOYER RECOMMENDS THE USE OF GENUINE HOYER PARTS Hoyer slings and lifters are not designed to be interchangeable with other manufacturer s products Using other manufacturer s products on Hoyer products is potentially unsafe and could result in serious injury to patient and or caregiver AWARNING Refer to maximum weight capacity of lift Sling capacity is limited by the maximum capacity of the lift 5 Lifting with the Hoyer Ascend Position Standaid so that the patient s feet fit in the foot tray and knees rest against the knee pad Initially attach the longer loops of the sling to the grey hooks at the end of the Standaid hand grips The patient s hands should be placed on the handgrips Once the patient is used to the lift the shor
15. ng CATEGORIES of lift within the working parameters of the lifts specified in the TECHNICAL SPECIFICATIONS e Category A Wheelchair e Category D Toilet Shower Chair The CE mark The Hoyer Ascend carries the CE mark and complies with the following EC directives e Medical Device Directive 93 42 EEC EMC Directive 89 336 EEC e Low Voltage Directive 73 23 EEC 4 294000 10063 Rev A English mayer Ascend Assembly and Commissioning Instructions CARTON CONTENTS Place the carton in a clear working area and open carefully The carton contains Hoyer ASCEND LIFT WALLET CONTAINING DOCUMENTS HAND CONTROL BATTERY PACK CHARGING LEAD DESK TOP CHARGER STAND A WARNING The Hoyer Ascend is heavy and will need to be lifted with care You may need assistance to lift the Hoyer Ascend from the carton ASSEMBLY Remove all the parts from the carton and place on the floor taking care to protect the finish from damage 5 294000 10063 Rev A Hoyer English Ascend 1 Place the chassis in a clear space and apply the rear bakes Attach the foot tray to the base using the location holes positioned on tbe base casting 3 Tighten the mast assembly with the mast locking device which is located at the front of the chassis WARNING Avoid trapping fingers Keep fingers away from the end of the mast when inserting into the chassis socket Full engagement of the mast is indicated
16. om Assembly 97 Ibs 44 0 kg POWOMIPACK cccecdcasswescccssetevvassnpastensannsnescitinanaatsapacececssessts 6 6 Ibs 3 kg Total eee a 103 6 Ibs 47 0 kg Base Assembly not inc battery seesssseierrreerieeree 42 9 Ibs 19 5 kg Mast amp Boom not inc batter 45 1 Ibs 20 5 kg All measurements are within a 5 5 degree of tolerance 19 294000 10063 Rev A Hoyer English Ascend ELECTRICAL SPECIFICATIONS BATTERIES censngnuosurenn aaa 12 volt Rechargeable sealed lead acid type BATTERY CAPACITY isisisi 3 2 Ampere hours CHARGER RATED INPUT gt iissa 230Vac 50 60Hz CHARGER RATED OUTPUT siani 27 4 29 0 VDC 0 8A Electric Shock Protection CHARGER CLASS II IEN INTERNAL POWER SOURCE Degree of Shock Protection CHARGER oreeson i earen A Ta a EEE aA TYPE B IK TYPE B INTENDED OPERATING ENVIRONMENT 00 gt 5 lt 40 Outside this environment functionality and safety may be compromised 20 294000 10063 Rev A English Hayer Ascend 11 Warranty This warranty covers HoyerPro lifts only Lifts not covered under this warranty include but are not limited to Advance H HML400 HPL600WB HPL600WBSC HPL402 C HLA and variations HoyerPro lifts are guaranteed for a period of two years from the date of delivery against defects in materials and workmanship under normal use and service This warranty includes all mechanical and electrical components Aluminium structural components and mec
17. sling and patients must be assessed for suitability by a qualified person Transport Sling Attachment Loop Straps Shoulder Chest Supports and Buckle Leg Supports Attachment Loop Straps Legs Feed the sling down the back of the patient leaving the top of the commode aperture at the base of the spine Check the roll part of the sling is square across the patient s back Attach the support strap around the chest of the patient This strap need not be tight It is there to hold the sling in position whilst attaching the loops to the Standaid It may be left off altogether if preferred Ensure patient s arms are on the outside of the sling Raise the patient s leg and feed the leg strap under and up between the legs Ensure the sling is not twisted or creased under the thigh Repeat this procedure for the other leg Attach the loops on the roll parts of the sling to the white hooks at the end of the hand grips Without crossing the loops on the leg straps attach to left and right black knobs on the lifting fork You would normally use the middle of the three loops The patient is now ready to be raised from the seat Once clear of the seat the patient will be more comfortable if lowered back in to the sitting position Joerns Healthcare recommends slings are checked regularly and before use for fraying or damage Do not use slings that are worn or damaged 8 294000 10063 Rev A Hoyer English Ascend Standing Sli
18. ter loops may be used to achieve a more upright position Then push UP button on handcontrol to raise the patient to the standing position 10 294000 10063 Rev A English Beyer Ascend 6 Safety Precautions Please read and follow the safety precautions listed below The operation and use of Hoyer patient lifts is simple and straightforward Following these few basic safety precautions will make lifting operations easy and trouble free READ AND UNDERSTAND THE USER INSTRUCTION MANUAL BEFORE USING YOUR ASCEND A WARNING e ALWAYS plan your lifting operations before commencing e ALWAYS carry out the DAILY CHECK LIST before using the lift e ALWAYS familiarise yourself with the operating control and safety features of a lift before lifting a patient e DO NOT use a sling unless it is recommended for use with the lift e ALWAYS check the sling is suitable for the particular patient and is of the correct size and capacity e NEVER use a sling which is frayed or damaged e ALWAYS fit the sling according to the instructions provided user instructions e DO NOT exceed the safe working load e ALWAYS check the safe working load of the lift is suitable for the weight of the patient e ALWAYS carry out lifting operations according to the instructions in the user manual e NEVER disconnect or bypass a control or safety feature because it seems easier to operate the lift e DO NOT lift a patient with the castor brakes o
19. ut by an authorized service dealer 10 BASE AND WHEELS Ensure base is even and level viviy all four wheels are on the floor 11 SLINGS Check for wear and fraying XA 12 LUBRICATION Oil pivot joints including mast and boom connections spreader bar joint only if required 13 HAND SET Ensure plugged fully into controller IL 14 FIXINGS Check all nuts bolts screws and fasteners for excessive wear and for tightness Replace as required 18 294000 10063 Rev A English Hayer Ascend 10 Technical Specification Safe Working Load sssssssessssesssrersrresssresnsesnrinsnreesrrese 375 Ibs 170 kg Maximum Overall Length 43 3 inches 1100 mm Minimum Overall Length 40 8 inches 1035 mm Maximum Overall Heioht cece eens 66 5 inches 1690 mm Minimum Overall Helaht eects 48 4 inches 1230 mm Maximum Height to attachment point 64 7 inches 1644 mm Minimum Height to attachment point 37 inches 940 mm TUMING RAGIUS sssini a 51 9 inches 1320 mm Legs Open External Wd 39 1 inches 995 mm Legs Open Internal Width werent 34 8 inches 885 mm Legs Closed External Width oo 24 8 inches 630 mm Legs Closed Internal Width oo cence 20 0 inches 510 mm Widest Point between support handles 0 0 0 cece 28 9 inches 735 mm Overall Height Of L gS iiinis 4 7 inches 120 mm Ground Clearance iaiia 1 4 inches 35 mm Front Twin er 4 0 inches 100 mm Rear Braked Castors 4 0 inches 100 mm Weights Mast Base A Bo
Download Pdf Manuals
Related Search
Related Contents
Silvercrest SFE450A1-05/10-V2 User's Manual Guida per l`utente di X5400 Series Gefen EXT-DVI-144DL User's Manual instruction manual gebruiksaanwijzing bedienungsanleitung Communication Port 緊急災害用煮炊釜 野外での炊き出しに! Brochure 25280-100(400) PowerClean Ultra Chlorinator Instructions CLAMPP group Business Card Exchange User Manual Garmin 3000 Marine GPS System User Manual Copyright © All rights reserved.