Digital Phosphor Oscilloscopes - DPO7000C Series

image

Contents

1. DPOPWR Measurement t Sources Select ice Switchi A n a Power Device Switching Loss M Chi Ch2 Configure Power Loss Report Min Max Average Min Max Average 10 1mvv 10 2mvv 10 2mw 74 0uJ 74 8uJ 74 4uJ f 26 6mW 27 0MW 26 8mW 195uJ 198uJ 196uJ Avg Loss 51 3mW Avg Energy 375uJ AAA fi Total Avg Switching Loss measurements Automated power measurements enable quick and accurate analysis of common power parameters FOPRSM WH coos i Details va Select View Expand Description Mean Std Dev Max Min p p Population Max cc Min cc ie Configure di Single Fregi Ch1 98 535MHz 862 03kHz 100 18MHz 96 852MHz 3 3298MHz 4926 492 59kHz 485 93kHz es Show Plots I Advanced Analysis Jitter Eye Diagram and Timing measurements one touch wizard makes setup for jitter measurements easy DPOJET Advanced is also a measurement framework that works in conjunction with standards specific compliance test packages for applications such as DDR memory and USB www tektronix com 7 Data Sheet Mask testing an OC 12 signal capturing any violations of the mask Limit and Mask Testing Optional The optional limit test Option LT and mask test Option MTM software packages are useful for long term signal monitoring characterizing signals during design and testing on a production line The limit test software 8 www tektro
2. Digital Phosphor Oscilloscopes DPO7000C Series Data Sheet gita Phosphor Os illoscope Te ktronix DPO 7354C Digital pi a a a 7 a Features amp Benefits Key Performance Specifications 3 5 GHz 2 5 GHz 1 GHz and 500 MHz Bandwidth Models Up to 40 GS s Real time Sample Rate on One Channel up to 20 GS s on Two Channels and up to 10 GS s on Three or Four Channels Up to 500 Megapoint Record Length with MultiView Zoom gt 250 000 wims s Maximum Waveform Capture Rate with FastAcg FastFrame Segmented Memory Acquisition Mode with gt 310 000 Waveforms per Second Capture Rate User selectable Bandwidth Limit Filters for Better Low frequency Measurement Accuracy Ease of Use Features Pinpoint Triggering provides the Most Flexible and Highest Performance Triggering with over 1400 Combinations to Address Virtually Any Triggering Situation Visual Trigger Precisely Qualifies Triggers and Finds Unique Events in Complex Waveforms Advanced Search and Mark to Find Specific Events in the Entire Waveform MyScope Custom Control Windows and Right Mouse Click Menus for Exceptional Efficiency 53 Automated Measurements Waveform Histograms and FFT Analysis for Simplified Waveform Analysis TekVPI Probe Interface supports Active Differential and Current Probes for Automatic Scaling and Units m 12 1 in 307 mm Bright XGA Display with Touch Screen Connectiv
3. Description Liquid crystal active matrix color display with touch screen Diagonal 12 1 in 307 mm 1024 horizontal x 768 vertical pixels XGA Vectors Dots Variable Persistence Infinite Persistence Normal Green Gray Temperature Spectral and User Defined YT XY Computer System and Peripherals Characteristic Operating System CPU PC System Memory Hard Disk Drive CD DVD Drive Mouse Keyboard Description Windows 7 Ultimate 64 bit Intel Core 2 Duo 22 GHz processor 28 GB Removable hard disk drive 2160 GB capacity 2 5 in SATA Front panel CD R W DVD R drive Optical wheel mouse USB interface Order 119 7083 xx for small keyboard USB interface and hub www tektronix com 15 Data Sheet Input Output Ports Port USB 2 0 High speed Host Ports GPIB Port LAN Port Video Out Port Audio Ports Keyboard Port Mouse Port Auxiliary Input Auxiliary Out Software switchable External Reference In Analog Signal Output Probe Compensator Output Recovered Clock DPO7254C and DPO7354C only Recovered Data DPO7254C and DPO7354C only Description Supports USB mass storage devices printers keyboard and mouse Ports on front and side panels of the instrument Can be disabled individually Rear panel IEEE488 2 connector RJ 45 connector supports 10 100 1000BASE T DVI I connector connect to show the oscilloscope display on an external monitor or projector Support for extended de
4. Opt MTM Mask Testing for ITU T ANSI T1 102 Ethernet SONET SDH Fibre Channel USB 2 0 IEEE 1394b Rapid I O OIF CPRI and Serial Video includes hardware clock recovery on DPO7254C DPO7354C Opt PWR Power Measurement and Analysis Opt SR COMP Computer Serial Triggering and Analysis RS 232 422 485 UART Enables triggering on packet level information on RS 232 422 485 UART buses as well as analytical tools such as digital views of the signal bus views and packet decoding Opt SR CUST Custom Serial Analysis Kit for Developers Opt SR DPHY MIPI D PHY Serial Analysis Enables analysis of MIPI DSI 1 and CSI 2 buses with analytical tools such as digital views of the signal bus views and packet decoding Opt SR EMBD Embedded Serial Triggering and Analysis 12C SPI Enables triggering on packet level information on 12C and SPI buses as well as analytical tools such as digital views of the signal bus views and packet decoding Opt SR USB USB 2 0 Serial Triggering and Analysis LS FS HS Enables triggering on packet level content for low speed and full speed USB serial buses Also enables analytical tools such as digital views of the signal bus views and packet decoding for low speed full speed and high speed USB serial buses USB High Speed supported only on 21 GHz models Opt ST1G S 8b 10b Serial Protocol Trigger and Decode up to 1 25 Gb s Opt SVE SignalVu Essentials Vector Signal Analysis Opt SVM 6 SignalVu Ge
5. 50 mV div 1 V 50 5 mV div to 99 5 mV div 1 5 V 10 divisions 100 mV div to 500 mV div 10 V 505 mV div to 995 mV div 15 V 10 divisions 1 Vidiv to 5 V div 100 V 5 05 Vidiv to 10 V div 150 V 10 divisions 1 mV div to 9 95 mV div 0 2 x offset position 0 1 div 1 5 mV 10 mV div to 99 5 mV div 0 35 x offset position 0 1 div 1 5 mV 100 mV div to 1 V div 0 35 x offset position 0 1 div 15 mV 1 01 V div to 10 V div 0 25 x offset position 0 1 div 150 mV gt 100 1 at lt 100 MHz gt 30 1 between 100 MHz and 2 5 GHz gt 20 1 between 2 5 GHz and 3 5 GHz www tektronix com 11 Data Sheet Horizontal System Analog Channels Characteristic DPO7054C DPO7104C DPO7104C with Option 2SR DPO7254C DPO7354C Maximum Sample Rate 1 ch 20 GS s 20 GS s 40 GS s 40 GS s Maximum Sample Rate 2 ch 10 GS s 10 GS s 20 GS s 20 GS s Maximum Sample Rate 3 4 ch 5 GS s 5 GS s 10 GS s 10 GS s Maximum Equivalent Time 4 TS s Sampling Rate Maximum Record Length with 50M 1 ch 25M 2 ch 12 5M 3 4 ch Standard Configuration Maximum Record Length with 125M 1 ch 50M 2 ch 25M 3 4 ch Option 2RL Maximum Record Length with 250M 1 ch 125M 2 ch 50M 3 4 ch Option SRL Maximum Record Length with SE 500M 1 ch Option 10RL 250M 2 ch 125M 3 4 ch Maximum Duration at Highest 1 2 ms with standard record length up to 10 ms with optional record length Real time Sample Rate 1 ch Time Base Range
6. Events Reset by Time Reset by State Reset by Transition All sequences can include separate horizontal delay after the trigger event to position the acquisition window in time Communications related Requires Opt MTM Characteristic Trigger Sequences Triggers Support for AMI HDB3 BnZS CMI MLT3 and NRZ encoded communications signals Select among isolated positive or negative one zero pulse form or eye patterns as applicable to the standard Video Trigger Formats Triggers from negative sync composite video field 1 and Field Rates or field 2 for interlaced systems any field specific line or any line for interlaced or noninterlaced systems Supported systems include NTSC PAL SECAM and HDTV 1080 24sF 1080p 25 1080i 50 1080i 60 1080p 24 720p 60 480p 60 Serial Pattern Trigger DPO7254C and DPO7354C only requires Opt ST1G Up to 64 bit serial word recognizer bit specified in binary high low don t care or hex format Trigger on NRZ encoded data up to 1 25 Gb s Clock Recovery System DPO 254C and DPO7354C only requires Opt ST1G or MTM Clock Recovery Fixed at FBaud 500 Phase Locked Loop Bandwidth Clock Recovery 1 5 MBaud to 1 25 GBaud Frequency Range Clock Recovery Jitter 20 psrmvs 1 25 Unit Interval RMS for PRBS data patterns 20 PSrus 1 25 Unit Interval RMS for repeating 0011 data pattern Clock Recovery 5 of requested baud rate typical Tracking Acquisition Range Minimum Signal 1
7. Opt SR COMP Trigger on Start Bit End of Packet Data 1 5 words and Parity Error on RS 232 buses up to 10 Mb s CAN Optional SPI Optional RS 232 422 485 UART Optional Characteristic Advanced Search and Mark 14 www tektronix com Serial Pattern Optional Description Provided as part of Opt SR USB Low Speed Trigger on Sync Reset Suspend Resume End of Packet Token Address Packet Data Packet Handshake Packet Special Packet Error Token Packet Trigger Any token type SOF OUT IN SETUP Address can be specified for Any OUT IN and SETUP token types Address can be further specified to trigger on lt lt gt a particular value or inside or outside of a range Frame number can be specified for SOF token using Binary Hex Unsigned Decimal and Don t Care digits Data Packet Trigger Any data type DATAO DATA1 Data can be further specified to trigger on lt S lt gt 2 a particular data value or inside or outside of a range Handshake Packet Trigger Any handshake type ACK NAK STALL Special Packet Trigger Any special type Reserved Error Trigger PID Check CRC5 or CRC16 Bit _ Stuffing Full Speed Trigger on Sync Reset Suspend Resume End of Packet Token Address Packet Data Packet Handshake Packet Special Packet Error Token Packet Trigger Any token type SOF OUT IN SETUP Address can be specified for Any OUT IN
8. Oscilloscopes DPO7000C Series Software Software NI LabVIEW SignalExpress Tektronix Edition IVI Driver LXI Class C Web Interface Description A fully interactive measurement software environment optimized for the DPO7000C Series enables you to instantly acquire generate analyze compare import and save measurement data and signals using an intuitive drag and drop user interface that does not require any programming Standard DPO7000C Series support for acquiring controlling viewing and exporting your live signal data is permanently available through the software The full version SIGEXPTE adds additional signal processing advanced analysis mixed signal sweeping limit testing and user defined step capabilities and is available for a 30 day trial period standard with each instrument Provides a standard instrument programming interface for common applications such as LabVIEW LabWindows CVI Microsoft NET and MATLAB IVI COM standard Connect to the DPO7000C Series through a standard web browser by simply entering the oscilloscope s IP address in the address bar of the browser The web interface enables viewing of instrument status and configuration as well as status and modification of network settings All web interaction conforms to LXI Class C specification Display Characteristics Characteristic Display Type Display Size Display Resolution Waveform Styles Color Palettes Display Format
9. Pinpoint triggering using Silicon Germanium SiGe technology to provide trigger performance up to the bandwidth of the oscilloscope and over 1400 trigger combinations Most other trigger systems offer multiple trigger types only on a single event A event with the delayed trigger B event selection limited to edge type triggering and often do not provide a way to reset the trigger sequence if the B event doesn t occur But Pinpoint triggering provides a full suite of advanced trigger types on both A and B triggers with Reset triggering to begin the trigger sequence again after a specified time state or transition so that even events in the most complex signals can be captured Finding the right characteristic of a complex signal can require hours of collecting and sorting through thousands of acquisitions for the event of interest Defining a trigger that isolates the desired event and shows data only when the event occurs speeds up this process The optional Visual Trigger makes the identification of the desired waveform events quick and easy by scanning through all waveform acquisitions and comparing them to on screen areas geometric shapes With up to a 500M point record length you can capture many events of interest even thousands of serial packets in a single acquisition for further Digital Phosphor Oscilloscopes DPO7000C Series 500mV div 1MQ 4y 500M 2 0ms div 5 0GS s 200ps pt 500mV 100ns 500ns 500ns Single Seq RL 100
10. SR DPHY MIPI D PHY Serial Analysis Enables analysis of Service Options 9 MIPI DSI 1 and CSI 2 buses with analytical tools such ce as digital views of the signal bus views and packet Option Description decoding Opt C3 Calibration Service 3 Years DPOFL SR EMBD Embedded Serial Triggering and Analysis 12C SPI Opt C5 Calibration Service 5 Years Enables triggering on packet level information on 12C Opt DI Calibration Data Report and SPI buses as well as analytical tools such as digital views of the signal bus views and packet decoding Opt D3 Calibration Data Report 3 Years with Opt C3 DPOFL SR USB USB 2 0 Serial Triggering and Analysis LS FS Opt Ds Calibration Data Report 5 Years with Opt C5 HS Enables triggering on packet level content for Opt G3 Complete Care 3 Years includes loaner scheduled low speed and full speed USB serial buses Also calibration and more enables analytical tools such as digital views of the Opt G5 Complete Care 5 Years includes loaner scheduled signal bus views and packet decoding for low speed ica calibration and more full speed and high speed USB serial buses i i USB High Speed supported only on gt 1 GHz models Opt R3 Repair Service 3 Years including warranty DPOFL ST1G 3 8b 10b Serial Protocol Trigger and Decode up to Opt RS Repair Service 5 Years including warranty CGS S o r__ i 9 Probes and accessories are not included in the oscilloscope warranty Refer to the data she
11. as a probe menu button right on the probe itself This button brings up a probe menu on the oscilloscope display with all relevant settings and controls for the probe The TekVPI interface enables direct attachment of a current probe without requiring a separate power supply TekVPI probes can be controlled remotely through USB GPIB or Ethernet enabling more versatile solutions in ATE environments www tektronix com 9 Data Sheet MyScope Setup Choose From These Controls Click and Drag Controls onto the Tab below dia Standard Deviation New Tab ut 10 z Save u 20 Histogram Rename Tab u o7 Gap Save As RE I Reference Levels Measurement Gating 7 Source H Measurement Statisti Chi v User Pref He Help Histogram Mode Histo Size Histogram Scaling 2 0divs Histogram Limits Delet Histogram Location Reset Clos Mask lt Math Analyze H Utilities Marks_MyScope Acquisition Mode Sample Pk Detect A Triggertype Edge Runt Hi Res Average ray Ge Bus i Save B Triggertype Edge Save Save As MyScope custom control windows are created with a simple drag and drop process enabling each user to have a unique interface MyScope Custom Control Window Easily create your own personalized toolbox of oscilloscope features in a matter of minutes using a simple visual drag and drop proc
12. design goals requires analyzing its behavior Tasks can range from simple checks of rise times and pulse widths to sophisticated power loss analysis characterization of system clocks and investigation of noise sources The DPO7000C Series offers a comprehensive set of integrated analysis tools including waveform and screen based cursors 53 automated measurements advanced waveform math including arbitrary equation editing waveform histograms and FFT analysis Every DPO7000C Series oscilloscope includes the DPOJET Essentials jitter and eye pattern analysis software package extending the oscilloscope s measurement capabilities to make measurements over contiguous clock and data cycles in a single shot real time acquisition This enables measurement of key jitter and timing analysis parameters such as Time Interval Error and Phase Noise to help characterize possible system timing issues Analysis tools such as plots for time trends and histograms quickly show how timing parameters change over time and spectrum analysis quickly shows the precise frequency and amplitude of jitter and modulation sources Specialized application support for serial bus debug and compliance test jitter and eye pattern analysis power supply design limit and mask testing DDR memory bus analysis and wideband RF is also available Advanced Search and Mark A 12 5M point standard record length represents thousands of screens of information The DPO7000C Series e
13. div up to 1 25 GBaud typical Amplitude Needed for Clock Recovery Trigger Level Range Internal Trigger Level Aux In TekVPI interface 5 V 50 O 150 V CAT I derate at 20 dB decade to 9 Vams above 200 kHz 1 MQ Trigger Level Line Fixed at 0 V Trigger Coupling DC AC attenuates lt 60 Hz HF Rej attenuates gt 30 kHz LF Rej attenuates lt 80 kHz Noise Reject reduces sensitivity Trigger Holdoff Range 250 ns to 12 s 12 divisions from center of screen www tektronix com 13 Data Sheet Trigger Modes Mode Mode Description USB 2 0 Optional Edge Positive or negative slope on any channel or front panel auxiliary input Coupling includes DC AC HF reject LF reject and noise reject Glitch Trigger on or reject glitches of positive negative or either polarity Minimum glitch width is 170 ps typical with rearm time of 250 ps for DPO7254C or DPO7354C Width Trigger on width of positive or negative pulse either within or outside of selectable limits 225 ps to 10 s Runt Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again Event can be time or logic qualified Window Trigger on an event that enters or exits a window defined by two user adjustable thresholds Event can be time or logic qualified Timeout Trigger on an event which remains high low or either for a specified time period 300 ps to 1 s Trigger on pulse edge rates that are fas
14. scroll through the waveform counting and converting bits and looking for what caused the event With the DPO7000C Series you can have the oscilloscope automatically search through the acquired data for user defined criteria including serial packet content Each occurrence is highlighted by a search mark Rapid navigation between marks is as simple as pressing the Previous and Next gt buttons on the front panel CAN and LIN Timing and Protocol Decode Software Optional The optional CAN LIN serial analysis software package Option LSA enables you to ensure seamless and reliable operation of a CAN or LIN network The software measures oscillator tolerance and propagation delay on CAN buses provides CAN triggering and simultaneously decodes CAN and LIN messages File Edit Yertical Horiz Acq Trig Display Cursors Measure Mask Math MyScope Analyze Utilities Help B 200ns div 10 0GS s 100ps pt NA ci PAGA 04 ERIN CLG 50Q Ry 1 0G 181 acqs RL 20 0k Man amp File Measurements Results Utilities Help Fi Eye PASS Rising Edge Rate PASS Diagram Waveform Press the Result Status Eas ig a e PASS Plot Buttons for details of that est i PASS Additional information y Pass ae Exit Hide PASS PASS USB 2 0 Compliance Testing Serial Bus Compliance Test Optional Software packages for automated compliance test are available for MIPI D PHY Option D PHY Etherne
15. the industry s most comprehensive search and waveform navigation with the standard Advanced Search and Mark feature and front panel controls User marks allow you to mark any location that you may want to reference later for further investigation Or automatically search your entire record for the criteria you define Along the way it will automatically mark every occurrence of your defined event so you can quickly move between events The advanced search and mark capability of the DPO7000C Series can search for up to eight different events simultaneously and stop a live acquisition when it finds an event of interest saving even more time www tektronix com 3 Data Sheet File Edit Yertical Horiz Acq Trig Display Cursors Measure Mask Math MyScope Analyze Utilities Help B 20 0ns div 5 0GS s 200ps pt 1MQ By 500M A ci 1 94v Horz Dly 406ns FastAcq Sample 3 634 050 acqs RL 1 0k Value M in ax St Dev Count Info ean fons 0559653 fen OB OOS seo ev 6 156ns 6 1551697m ss6 0p__ o A8 m 4936p ss60_ a Jia oo pseo Analyze Waveform histogram of a falling edge showing the distribution of edge position jitter over time Included are numeric measurements made on the waveform histogram data A comprehensive set of integrated analysis tools speeds verification of your design s performance Analyze Verifying that your prototype s performance matches simulations and meets the project s
16. 00800 2255 4835 USA 1 800 833 9200 European toll free number If not accessible call 41 52 675 3777 Updated 10 February 2011 For Further Information Tektronix maintains a comprehensive constantly expanding collection of application notes technical briefs and other resources to help engineers working on the cutting edge of technology Please visit www tektronix com Copyright Tektronix Inc All rights reserved Tektronix products are covered by U S and foreign patents issued and pending Information in this publication supersedes that in all previously published material Specification and price change privileges reserved TEKTRONIX and TEK are registered trademarks of Tektronix Inc All other trade names referenced are the service marks trademarks or registered trademarks of their respective companies 19 Jan 2012 48W 26543 6 Tektronix
17. 50 ps div to 1000 s div 50 ps div to 1000 s div 25 ps div to 1000 s div 25 ps div to 1000 s div Time Resolution in ET IT mode 500 fs 500 fs 250 fs 250 fs Time Base Delay Time Range 5 ns to 250 s Channel to Channel Deskew 75 ns Range Delta Time Measurement 0 06 sample rate 2 5 ppm x Reading RMS Accuracy Trigger Jitter RMS 1 5 psrms With enhanced triggering OFF lt 100 fsrus with enhanced triggering ON Jitter Noise Floor lt 1 psrms lt 2 PSpeax for record duration lt 10 ps typical lt 2 5 psrms for record duration lt 30 ms lt 65 parts trillion for record durations lt 10 s Time Base Accuracy 2 5 ppm aging lt 1 ppm per year 12 www tektronix com Acquisition Modes Mode Description Sample Acquire sampled values Peak Detect Captures narrow glitches at all real time sampling rates 1 sample rate at lt 10 GS s Averaging From 2 to 10 000 waveforms included in average Envelope From 1 to 2x109 waveforms included in min max envelope Hi Res Real time boxcar averaging reduces random noise and increases resolution Roll Scrolls sequential waveform points across the display in a right to left rolling motion at sweep speeds slower than 50 ms div Up to 10 MS s with a maximum record length of 40M FastAcq Acquisition Mode FastAcq optimizes the instrument for analysis of dynamic signals and capture of infrequent events Maximum FastAcq gt 250 000 wfms s on all 4 channels simultaneously Waveform Capture Rate Wavef
18. 500 MHz TekVPI differential voltage probe with 42 V differential input voltage 20 MHz TekVPI 150 Ampere AC DC current probe 120 MHz TekVPI 30 Ampere AC DC current probe 750 V 200 MHz high voltage differential probe 1 5 kV 200 MHz high voltage differential probe 6 kV 100 MHz high voltage differential probe 2 5 kV 500 MHz 100X high voltage passive probe 20 kV 75 MHz high voltage passive probe 3 GHz 20X low capacitance passive probe 10 Requires TekVPI to TekProbe BNC adapter TPA BNC Accessories Accessory 077 0076 xx 077 0010 10 077 0063 05 English PDF only NI LabVIEW SignalExpress Tektronix Edition Software SIGEXPTE 016 1985 02 065 0881 xx 016 1979 xx 119 7083 xx 119 6297 xx 016 1970 xx K420 Description Service Manual English PDF only Programmer Manual English PDF only Performance Verification and Specifications Manual Full Version Rackmount Kit Removable HD Spare with rotational media Front HD option for Rackmount Kit Mini Keyboard USB interface Full size keyboard with 4 port USB hub Transit Case Oscilloscope Cart Digital Phosphor Oscilloscopes DPO7000C Series Cables Cable 012 0991 xx 012 0991 xx Test Fixtures Fixture 067 1686 xx TDSUSBF TF GBE BTP TF GBE ATP TF GBE EE Adapters Adapter TPA BNC P6701B 10 P6703B 10 Description GPIB Cable 1 m GPIB Cable 2 m Description Probe Calibration Power Deskew Test Fixture Test fixture for use w
19. Digital Visual Interface Compliance Testing ET3 5 Add Opt ET3 Ethernet Compliance Testing LSA Add Opt LSA CAN LIN Trigger Decode and Analysis LT Add Opt LT Waveform Limit Testing MTM Add Opt MTM Mask Testing PWR Add Opt PWR Power Measurement and Analysis SR COMP Add Opt SR COMP Computer Serial Triggering and Analysis RS 232 422 485 UART SR CUST Add Opt SR CUST Custom Serial Analysis Kit for Developers 20 www tektronix com Option Description SR DPHY Add Opt SR DPHY MIPI D PHY Serial Analysis DSI 1 and CSI 2 SR EMBD Add Opt SR EMBD Embedded Serial Triggering and Analysis 12C SPI SR USB Add Opt SR USB USB 2 0 Serial Triggering and Analysis LS FS HS SSD Add Opt SSD Solid State Hard Drive ST1G 3 Add Opt ST1G 8b 10b Serial Protocol Trigger and Decode up to 1 25 Gb s SVEM Add Opt SVE SignalVu Essentials Vector Signal Analysis SVM 6 Add Opt SVM SignalVu General Purpose Modulation Analysis SVO 6 Add Opt SVO Flexible OFDM Analysis SVP 6 Add Opt SVP SignalVu Pulse Advanced Signal Analysis SVT 6 Add Opt SVT Settling Time Measurements Frequency and Phase USB 8 Add Opt USB USB 2 0 Compliance Testing VETM Add Opt VET Visual Trigger and Search 1 Requires Opt DJA 2 Available on 21 GHz models only 3 Available on 22 5 GHz models only 4 Available on DPO7354C model only 5 Requires TF GBE BTP or TF GBE ATP Ethernet Test Fixture 6 R
20. M Results Mark Table Index Type Sre 6 Runt C1 3 277ms 0 7 Glitch C1 175 6ns 9 Glitch C1 10 Runt C1 L_ ti Glitch Search Results of an advanced search for a runt pulse or a narrow glitch within a long waveform record Each instance of the runt or glitch is automatically marked for easy reference analysis while maintaining high resolution to zoom in on fine signal details Investigate multiple segments of your waveform capture simultaneously with MultiView Zoom to quickly compare events in real time FastFrame Segmented Memory mode enables you to make efficient use of large records by capturing many trigger events in a single record eliminating large time gaps between events of interest View and measure the segments individually or as an overlay From triggering on specific packet content to automatic decode in multiple data formats the DPO7000C Series provides integrated support for a broad range of serial buses I2C SPI RS 232 422 485 UART USB 2 0 CAN LIN and MIPI D PHY The ability to decode up to 16 serial buses simultaneously means you gain insight into system level problems quickly Search Finding your event of interest in a long waveform record can be time consuming without the right search tools With today s record lengths pushing beyond a million data points locating your event can mean scrolling through thousands of screens of signal activity The DPO7000C Series offers
21. and SETUP token types Address can be further specified to trigger on lt lt gt a particular value or inside or outside of a range Frame number can be specified for SOF token using Binary Hex Unsigned Decimal and Don t Care digits Data Packet Trigger Any data type DATAO DATA1 Data can be further specified to trigger on lt S lt gt 2 a particular data value or inside or outside of a range Handshake Packet Trigger Any handshake type ACK NAK STALL Special Packet Trigger Any special type PRE Reserved Error Trigger PID Check CRC5 or CRC16 Bit Stuffing o High Speed No protocol level triggering Note High Speed support only available on 21 GHz models Provided as part of Opt LSA Provided as part of Opt ST1G Captures serial data stream with built in clock recovery for NRZ standards up to 1 25 Gb s Extended with pattern lock triggering to capture repeated acquisitions of long serial data patterns Search and Mark Events Description Automatically mark events and document waveforms Search positive negative slopes or both glitches runts pulse widths transition rate setup and hold timeout windows or find any logic or state pattern on any number of channels Search DDR Read or Write bursts with Opt DDRA Event table summarizes all found events All events are time stamped in reference to trigger position Stop acquisitions when an event is found Waveform Measur
22. arker on Selected Row Set Zero Timestamp to Hide Controls POO DO D Frame Tools Save Sensor Wfm Stuff Bit Wim View i Half M1 1 2459s M2 1 24585 AT 102 19us M3 1 14395 1 0388 AT 105 08ms CAN DW Protocol Analysis for Ch1 ID DATA ACK TIMESTAMP FRAME INFO DATA TIMESTAMP ERROR 1EF C1C2C3C04 0 0 00s DATA STD 1 14655 1FFFFFFF FF FF FFFF BEBEBE 7B 7E 9A 9C 100 TA DO 88 64 73 931 74ms _ PT 101 01 03 0 5 8665ms TA E7 824 58ms i 10000001 1122334455 0 6 0007ms DATA EXT E4 2A 86 717 54ms 114395 700356598 103885 12345678 112233445 3F DB CC BD _ 610 38ms 1597EEB2 FF FF 0000E DATA EXT 82 C5 B9 6F 503 27ms 519 42 69 6C 6C 6 7691ms TA B4 F6 77 FA 396 15ms 1597EEB2 AE4FFFFIO 6 9273ms E OOFFFFFF 28911ms 1 pe 527DE32 28249ms 140014 1122 33 0 7 3597ms TA 2F 45 C3 181 95ms 160016 1122334455 0 7 5500ms 1E AF 7499 74 839ms C1 18181818 FIF2F3F4F 0 7 7721ms DATA EXT 54 43 AQ 2E 32 201ms 0 DATA EXT 124881 16 139 37ms 757 OTE S 98 1D E7 353 57ms TASSAASS E 6 6723 46061m 57 45 68 6C 657 E DC 20 34 8E _ __567 78ms 1597EEA3 DE 55 CBFA F 674 90ms Checksum 1122 i TA e744ms CS 15 1122 3344 TA 7003 BB 98 _ 782 52ms c 17 112233445 DO 88 64 73 889 69ms CAN and LIN Timing and Protocol Decode you do In the past users had to manually
23. dustry s most complete visualization of signals providing fast insight into the real operation of your device Tektronix proprietary FastAcq technology delivers a fast waveform capture greater than 250 000 waveforms per second that enables you to see glitches and other infrequent transients within seconds revealing the true nature of device faults A digital phosphor display with color intensity grading shows the history of a signal s activity by using color to identify areas of the signal that occur more frequently providing a visual display of just how often anomalies occur M 81 Bus RS 232 5 0ms div 2 0MS s 500ns pt Single Seq RL 100k Trigger Bus Capture Triggering on a specific transmit data packet going across an RS 232 bus A complete set of triggers including triggers for specific serial packet content ensures you quickly capture your event of interest Capture Discovering a device fault is only the first step Next you must capture the event of interest to identify root cause The DPO7000C Series provides a complete set of triggers including runt glitch width timeout transition pattern state setup hold violation window comm and serial pattern to help quickly find your event Enhanced Triggering reduces trigger jitter at the trigger point In this mode the trigger point can be used as a measurement reference To enable complex system debug and validation the DPO7000C Series provides
24. ements Measurement Cursors Description Waveform and Screen Automatic Measurements 53 of which 8 can be displayed on screen at any one time Mean Minimum Maximum Standard Deviation User definable reference levels for automatic measurements can be specified in either percent or units Isolate the specific occurrence within an acquisition to take measurements on using either screen or waveform cursors Amplitude High Low Maximum Minimum Peak to Peak Mean Cycle Mean RMS Cycle RMS Positive Overshoot Negative Overshoot Measurement Statistics Reference Levels Gating Amplitude Related Time Related Rise Time Fall Time Positive Width Negative Width Positive Duty Cycle Negative Duty Cycle Period Frequency Delay Combination Area Cycle Area Phase Burst Width Waveform Histogram Waveform Count Hits in Box Peak Hits Median Measurements Maximum Minimum Peak to Peak Mean u Standard Deviation sigma u 1sigma u 2sigma u 3sigma Extinction Ratio absolute dB Eye Height Eye Width Eye Top Eye Base Crossing Jitter p p RMS 6sigma Noise p p RMS Signal Noise Ratio Eye pattern Measurements Cycle Distortion Q factor Waveform Histograms A waveform histogram provides an array of data values representing the total number of hits inside of a user defined region of the display A waveform histogram is both a visual graph of the hit distribution as well as a numeric array of values
25. equires Opt SVE 8 Requires TDSUSBF USB Test Fixture 22 GHz bandwidth required for high speed USB Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar Digital Phosphor Oscilloscopes DPO7000C Series www tektronix com 21 Data Sheet 22 www tektronix com Digital Phosphor Oscilloscopes DPO7000C Series www tektronix com 23 Data Sheet www tektronix com Contact Tektronix ASEAN Australasia 65 6356 3900 Austria 00800 2255 4835 Balkans Israel South Africa and other ISE Countries 41 52 675 3777 Belgium 00800 2255 4835 Brazil 55 11 3759 7627 Canada 1 800 833 9200 Central East Europe and the Baltics 41 52 675 3777 Central Europe amp Greece 41 52 675 3777 Denmark 45 80 88 1401 Finland 41 52 675 3777 France 00800 2255 4835 Germany 00800 2255 4835 Hong Kong 400 820 5835 India 000 800 650 1835 Italy 00800 2255 4835 Japan 81 3 6714 3010 Luxembourg 41 52 675 3777 Mexico Central South America amp Caribbean 52 55 56 04 50 90 Middle East Asia and North Africa 41 52 675 3777 The Netherlands 00800 2255 4835 Norway 800 16098 People s Republic of China 400 820 5835 Poland 41 52 675 3777 Portugal 80 08 12370 Republic of Korea 001 800 8255 2835 Russia amp CIS 7 495 7484900 South Africa 41 52 675 3777 Spain 00800 2255 4835 Sweden 00800 2255 4835 Switzerland 00800 2255 4835 Taiwan 886 2 2722 9622 United Kingdom amp Ireland
26. ess Once created these custom control windows are easily accessed through a dedicated MyScope menu selection on the oscilloscope This is ideal in a shared resource environment where each person can have their own custom control interface suited to their particular use MyScope control windows benefit all oscilloscope users eliminating the ramp up time that many face when returning to the lab after not using an oscilloscope for a while and enabling power users to be far more efficient Floating Licenses Floating licenses offer an alternative method to manage your Tektronix asset Floating licenses allow license key enabled options to be easily moved among all your MSO DPO5000 DPO7000 and DPO DSA MSO70000 Series of Tektronix oscilloscopes Floating licenses are available for many license key enabled options To order a floating version of an option license add DPOFL prefix to the option name e g DPOFL ET3 10 www tektronix com Check www tektronix com for additional information about floating license options Interoperability with Logic Analyzer for Digital Design and Debug The Tektronix Integrated View iView data display enables digital designers to solve signal integrity challenges and effectively debug and verify their systems more quickly and easily This integration allows designers to view time correlated digital and analog data in the same display windows and isolate the analog characteristics of the digital s
27. et for each DPOFL SVE SignalVu Essentials Vector Signal Analysis probe for its unique warranty and calibration terms DPOFL SVM 6 SignalVu General Purpose Modulation Analysis DPOFL SVO 6 Flexible OFDM Analysis DPOFL SVP 6 SignalVu Pulse Advanced Signal Analysis DPOFL SVT 6 Settling Time Measurements Frequency and Phase DPOFL USB 8 USB 2 0 Compliance Testing DPOFL VET Visual Trigger and Search 1 Requires Opt DJA 2 Available on 21 GHz models only 3 Available on 22 5 GHz models only 4 Available on DPO7354C model only 5 Requires TF GBE BTP or TF GBE ATP Ethernet Test Fixture 6 Requires Opt SVE 8 Requires TDSUSBF USB Test Fixture 22 GHz bandwidth required for high speed USB 18 www tektronix com Recommended Accessories Probes Tektronix offers over 100 different probes to meet your application needs For a comprehensive listing of available probes please visit www tektronix com probes Probe TAP3500 TAP2500 TAP1500 TDP3500 TDP1500 TDP1000 TDP0500 TCP0150 TCP0030 TMDP0200 THDP0200 THDP0100 P5100A P6015A P6158 Description 3 9 GHz TekVPI active single ended probe 2 9 GHz TekVPI active single ended probe 1 5 GHz TekVPI active single ended probe 3 5 GHz TekVPI differential voltage probe with 2 V differential input voltage 1 5 GHz TekVPI differential voltage probe with 8 5 V differential input voltage 1 GHz TekVPI differential voltage probe with 42 V differential input voltage
28. ght by showing you time variant behavior of these wideband signals Designed to Make Your Work Easier Large High resolution Display The DPO7000C Series features a 12 1 in 307 mm XGA color display with an integrated touch screen for seeing intricate signal details Dedicated Front panel Controls Per channel vertical controls provide simple and intuitive operation No longer do you need to share one set of vertical controls across all four channels al Digital Phosphor Oscilloscopes DPO7000C Series TekVPI probe interface simplifies connecting your probes to the oscilloscope Connectivity USB 2 0 host ports on the front and side panels enable easy transfer of screenshots instrument settings and waveform data to a USB thumb drive The rear panel contains a GPIB port for controlling the oscilloscope remotely from a computer An integrated 10 100 1000BASE T Ethernet port enables easy connection to networks and a Video Out port allows the oscilloscope display to be exported to an external monitor or projector PS 2 ports for keyboard and mouse are included for security conscious applications that require the USB ports to be disabled A standard removable hard disk drive makes customizing settings for different users easy as well as enables use in secure environments TekVPI Probe Interface The TekVPI probe interface sets the standard for ease of use in probing TekVPI probes feature status indicators and controls as well
29. ignals that are causing system failures No user calibration is required And once set up the iView feature is completely automated Remote Operation and Extended Analysis There are many ways to connect to your DPO7000C Series oscilloscope to conduct extended analysis The first makes use of the Windows Remote Desktop capability connect directly to your oscilloscope and operate the user interface remotely through the built in Remote Desktop A second way to connect is through Tektronix OpenChoice software which makes use of the fast embedded bus transferring waveform data directly from acquisition to analysis applications on the Windows desktop at much faster speeds than conventional GPIB transfers Industry standard protocols such as TekVISA interface and ActiveX controls are included for using and enhancing Windows applications for data analysis and documentation IVI COM instrument drivers are included to enable easy communication with the oscilloscope using GPIB serial data and LAN connections from programs running on the instrument or an external PC Or use the Software Developer s Kit SDK to help create custom software to automate multistep processes in waveform collection and analysis with Visual BASIC C C MATLAB LabVIEW LabWindows CVI and other common Application Development Environments ADE Microsoft Excel and Word toolbars are included to simplify data capture and transfer directly to these programs running o
30. ion mm in Top 0 0 Bottom 0 0 Left Side 76 3 Right Side 0 0 Front 0 0 Rear 0 0 Environmental Characteristic Description Temperature Operating 0 C to 50 C excluding CD R W drive 10 C to 45 C including CD R W drive Nonoperating 40 C to 71 C Humidity Operating 5 to 95 relative humidity RH with a maximum wet bulb temperature of 29 C at or below 50 C noncondensing Upper limit derated to 45 RH from 30 C to 50 C Nonoperating 5 to 95 relative humidity RH with a maximum wet bulb temperature of 29 C at or below 50 C noncondensing Upper limit derated to 45 RH from 30 C to 50 C Altitude Operating 10 000 ft 3 048 m Nonoperating 40 000 ft 12 190 m Regulatory Electromagnetic 2004 108 EC Compatibility Certifications UL61010 1 Second Edition CSA61010 1 Second Edition EN61010 1 2001 IEC 61010 1 2001 Ordering Information DPO7000C Series Product Description DPO7054C 500 MHz 5 10 20 GS s 4 2 1 ch 12 5M record length 4 channel digital phosphor oscilloscope DPO7104C 1 GHz 5 10 20 GS s 4 2 1 ch 12 5M record length 4 channel digital phosphor oscilloscope DPO7254C 2 5 GHz 10 20 40 GS s 4 2 1 ch 12 5M record length 4 channel digital phosphor oscilloscope DPO7354C 3 5 GHz 10 20 40 GS s 4 2 1 ch 12 5M record length 4 channel digital phosphor oscilloscope All Models Include One passive voltage probe per analog channel P6139B 500 MHz 10X 8 pF accessory
31. ith Opt USB Basic test package for 10 100 1000BASE T Ethernet tests Advanced test package for 10 100 1000BASE T Ethernet includes 1000BASE T jitter test channel cable Additional test fixture for Energy Efficient Ethernet measurements Order through Crescent Heart Software http www c h s com Description TekVPI to TekProbe BNC Adapter Optical Electrical Converter Multi Mode Optical Electrical Converter Single Mode 10 Requires TekVPI to TekProbe BNC adapter TPA BNC Software Software SIGEXPTE Description NI LabVIEW SignalExpress Tektronix Edition Software Full Version www tektronix com 19 Data Sheet Instrument Upgrades To upgrade your DPO7000C Series oscilloscope order DPO UP and option listed below For example DPO UP DDRA Option Description To upgrade record length RL02 From Standard Configuration to Opt 2RL Configuration RL05 From Standard Configuration to Opt SRL Configuration RL010 From Standard Configuration to Opt 10RL Configuration RL25 From Opt 2RL Configuration to Opt SRL Configuration RL210 From Opt 2RL Configuration to Opt 10RL Configuration RL510 From Opt 5RL Configuration to Opt 10RL Configuration To upgrade DPO7000C Series with DDRA 1 2 Add Opt DDRA DJAM Add Opt DJA Jitter and Eye Analysis Tools Advanced DPOJET D PHY 1 3 Add Opt D PHY MIPI D PHY Transmitter Debug Characterization and Compliance Test Solution DVI 4 Add Opt DVI
32. ity USB Host Ports on the Front and Side Panels for Quick and Easy Data Storage Printing and Connecting USB Peripherals Integrated 10 100 1000BASE T Ethernet Port for Network Connection and Video Out Port to Export the Oscilloscope Display to a Monitor or Projector Microsoft Windows 7 64 bit Operating System for Easy Connectivity and Integration into Your Environment LXI Class C Compliant Optional Serial Triggering and Analysis Automated Serial Triggering and Decode Options for 12C SPI RS 232 422 485 UART and USB 2 0 Automated Serial Analysis for MIPI D PHY DSI 1 and CSI 2 Automated Serial Decode and Vehicle Network Monitoring of CAN and LIN Clock Recovery from Serial Data Streams a 64 bit NRZ Serial Pattern Trigger for Isolation of Pattern dependent Effects up to 1 25 Gb s Optional Technology Specific Analysis Software Solutions provide Built in Domain Expertise for MIPI D PHY Ethernet and USB 2 0 Compliance Testing Jitter Timing Eye Diagrams Power DDR Memory Bus Analysis and Wideband RF Limit and Mask Testing provide Quick Insight into Signal Characteristics Tektronix Data Sheet Simplified Analysis for Complex Digital Designs With the DPO7000C Digital Phosphor Oscilloscope Series you can analyze analog and serial bus signals with a single instrument to quickly find and diagnose problems in complex designs Bandwidths up to 3 5 GHz and sample rates up to 40 GS s ensure y
33. n the Windows desktop A third way to connect to your oscilloscope is through NI LabVIEW SignalExpress Tektronix Edition enabling you to instantly acquire generate analyze compare import and save measurement data and signals using an intuitive drag and drop user interface that does not require any programming Characteristics Vertical System Analog Channels Characteristic Input Channels Bandwidth Rise Time 10 to 90 Typical Rise Time 20 to 80 Typical DC Gain Accuracy Bandwidth Limits Input Coupling Input Impedance Input Sensitivity Vertical Resolution Max Input Voltage 1 MQ Max Input Voltage 50 Q Position Range Delay between any Two Channels Typical Offset Range Offset Accuracy Channel to Channel Isolation Any two channels at equal Vertical Scale settings Typical DPO7054C 500 MHz 460 ps 310 ps Digital Phosphor Oscilloscopes DPO7000C Series DPO7104C DPO7254C DPO7354C 4 1 GHz 2 5 GHz 3 5 GHz 300 ps 160 ps 115 ps 200 ps 100 ps 95 ps 1 with offset position set to 0 Depending on instrument model 3 0 GHz 2 5 GHz 2 GHz 1 GHz 500 MHz 250 MHz and 20 MHz AC DC GND 1 MQ 1 with 13 pF 2 pF 50 O 1 1 MQ 1 mV div to 10 V div 50 Q 1 mV div to 1 V div 8 bit gt 11 bit with Hi Res 150 V CAT derate at 20 dB decade to 9 Vams above 200 kHz 5 Vams with peaks lt 24 V 5 divisions lt 100 ps 50 Q DC coupling and equal V div at or above 10 mV div 1 mV div to
34. nables you to find your event in seconds with Advanced Search and Mark 4 www tektronix com EF I UU Wu ATE TET EEE VELE AREE VELE EEE EI LELE PEE EE EXP 2 0Vidiv 1MQ Ry 500M A ci WEYN 50 0ms div 50 0MS s 20 0ns pt 02 2 0V div 1MQ y 500M Single Seq RL 25 0M Search Configure wi Type Source S Trig When 1 Width che oe 5 Mark Upper Linit Prev Next Settings sr Cioe ee Coo Copy Level Foniy Seticir Lower Limit Bring Cursor to Mark 900ns T Neg Cursor 1 Cursor2 Bring Zoom to Mark Zoom 2 Zoom 3 Search step 1 You define what you would like to find 7 RAND EIA NATIA TN ne bree ena n e irn erat AIA prin at nthe Mali Sept SP A ert nate end GIP 2 0V div 1MQ Ry 500M 50 0ms div 50 0MS s 20 0ns pt c2 2 0V div 1MQ Ay 500M Single Seq zici WA 2 5us 4 58ms 4 61ms acqs RL 25 0M zi ca FANY 2 5us 4 58ms 4 61ms Results Mark Table ime Delta im sec ms us ns D ps Width C2 3 829ms 000 008 488 660 000 Width width 1us Mark gt gt Type Description Width 3 375ms 000 000 454 299 999 Width width 1us 4 593ms 000 007 968 560 000 Prev Next gt V idth width 1 us C2 14 112ms 000 007 013 380 000 Width width 1us V idth width 1 us Set Clr Total Marks Bring Cursor to Mark Cursor 1 Cursor 2 J Search Marks All Marks View a Se Save Save all _ Clear Digits g
35. neral Purpose Modulation Analysis Opt SVO 6 Flexible OFDM Analysis Opt SVP 6 SignalVu Pulse Advanced Signal Analysis Opt SVT 6 Settling Time Measurements Frequency and Phase Opt USB 8 USB 2 0 Compliance Testing Opt VET Visual Trigger and Search TekExpress Application Framework TEKEXP TekExpress Application Framework TEKEXP Opt D PHY Automated Solution D PHYTX 1 3 TEKEXP Opt HEAC 3 7 HEAC Automated Solution TEKEXP Opt XGbT 4 10GBASE T Automated Solution Bundle Options Opt PS1 Power Solution Bundle DPOPWR P5205A TCP0030 TPA BNC 067 1686 xx Deskew Fixture 1 Requires Opt DJA 2 Available on 21 GHz models only 3 Available on 22 5 GHz models only 4 Available on DPO7354C model only 5 Requires TF GBE BTP or TF GBE ATP Ethernet Test Fixture 6 Requires Opt SVE 7 Requires Opt 2RL DJA MTM and ST1G 8 Requires TDSUSBF USB Test Fixture 22 GHz bandwidth required for high speed USB www tektronix com 17 Data Sheet Floating Option Licenses Power Plug Options Floating licenses offer an alternative method to manage your Tektronix asset Option Description Floating licenses allow license key enabled options to be easily moved among all Ont AO North America your MSO DPO05000 DPO7000 and DPO DSA MSO70000 Series of Tektronix se oscilloscopes Floating licenses are available for the following license key enabled Opt A1 Universal European Union options Opt A2 UK Opt A3 Australia Check www
36. nix com compares a tested signal to a known good or golden version of the same signal with user defined vertical and horizontal tolerances The mask test software includes a robust set of masks for telecommunications and computer standards for easily checking compliance to a standard Additionally custom masks can be created and used for characterizing signals With both software packages you can tailor a test to your specific requirements by defining test duration in a number of waveforms setting a violation threshold that must be met before considering a test a failure counting hits along with statistical information and setting actions upon violations test failure and test complete Whether specifying a limit template or a mask conducting pass fail tests in search of waveform anomalies such as glitches has never been easier DDR Memory Bus Analysis Optional The optional DDR memory analysis software package Option DDRA automatically identifies DDR1 DDR2 DDR3 LP DDR LP DDR2 and GDDR3 Reads and Writes and makes JEDEC conformance measurements with Pass Fail results on all edges in every Read and Write burst perfect for debugging and troubleshooting DDR memory buses Also provided are common measurements of clock address and control signals Used in conjunction with DPOJET Option DJA Option DDRA is the fastest way to debug complex memory signaling issues al Tektronix SignalVu File View Run Replay Markers Setup T
37. ools Window Help E gt S amp S amp TA Frequency 500 0 MHz a Eye Diagram 1 amp Q Freq Error 305 2 Hz Auto Reflev 0 00 dBm amp _s3 a Constellation Freq Error 305 2 Hz Auto RMS 0 788 Peak EVM 1 453 73 00 Sym E Spectrum Cani v Trace1 show Peak Normal AR 11 51 dBm gMR Pos M 0 0dN gl 100 00 dem CF 500 0 MHz Span 100 0 MHz CF 500 0 MHz Stopped Acq BW 100 00 MHz Acq Length 45 732 us Scope BW 1 000 GHz Scope sample rate 40 GS s PE ees TO le El Span 100 0 MHz SignalVu enables detailed analysis in multiple domains Vector Signal Analysis Optional The optional SignalVu vector signal analysis packages Options SVE SVM SVO SVP and SVT easily validate wideband designs and characterize wideband spectral events By combining the signal analysis engine of Tektronix real time spectrum analyzers with the wide bandwidth acquisition of Tektronix digital oscilloscopes you can now evaluate complex baseband signals directly on your oscilloscope You get the functionality of a vector signal analyzer a spectrum analyzer and the powerful trigger capabilities of a digital oscilloscope all in a single package Whether your design validation needs include wideband radar high data rate satellite links or frequency hopping communications SignalVu vector signal analysis software can speed your time to insi
38. orm Database Accumulate waveform database providing three dimensional array of amplitude time and counts FastFrame Acquisition Acquisition memory divided into segments maximum trigger rate gt 310 000 waveforms per second Time of arrival recorded with each event Frame Finder tool helps to visually identify transients Pinpoint Trigger System Characteristic Trigger Sensitivity Internal DC Coupled 0 7 div DC to 50 MHz increasing to 1 2 div at rated analog bandwidth typical up to 2 5 GHz 2 5 div at Description 3 5 GHz External Auxiliary Input 250 mV from DC to 50 MHz increasing to 350 mV at 1 MQ 250 MHZ typical Trigger Characteristics A Event and Delayed B Edge Glitch Width Runt Timeout Transition Time Event Trigger Types Logic Pattern Logic State Setup Hold Window all except Edge Pattern and State can be Logic State qualified by up to two channels Trigger Delay by Time 5 ns to 250 s Trigger Delay by Events 1 to 10 000 000 events Optional Serial Protocol 12C SPI RS 232 CAN USB 2 0 Trigger Types A Event only Main Trigger Modes Auto Normal and Single Enhanced Triggering User selectable corrects the difference in timing between the trigger path and the acquired data path supports all Pinpoint trigger types on both A and B Events except pattern trigger and not available in FastAcq Digital Phosphor Oscilloscopes DPO7000C Series Description Main Delayed by Time Delayed by
39. ou have the performance you need to see fast changing signal details To capture long windows of signal activity while maintaining fine timing resolution the DPO7000C Series offers a deep record length of up to 12 5M points standard on all channels and an optional record length of up to 500M points on one channel With Advanced Search and Mark and MultiView Zoom features for rapid waveform navigation and more than 15 optional software and analysis packages for common technologies and in depth analysis tasks the DPO7000C Series from Tektronix provides the feature rich tools you need to simplify and speed debug of your complex design Comprehensive Features Speed Every Stage of Debug The DPO7000C Series offers a robust set of features to speed every stage of debugging your design from quickly discovering an anomaly and capturing it to searching your waveform record for the event and analyzing its characteristics and your device s behavior Discover To debug a design problem first you must know it exists Every design engineer spends time looking for problems in their design a time consuming and frustrating task without the right debug tools 2 www tektronix com IA cs PERIN 100ns div 1 0GS s 1 0ns pt Sample 25 594 786 acqs RL 1 0k Auto Discover Fast waveform capture rate over 250 000 wfm s maximizes the probability of capturing elusive glitches and other infrequent events The DPO7000C Series offers the in
40. pouch front cover mouse 013 0347 00 VGA to DVI adapter quick start user manual DPO7000C Series product software media and documentation including performance verification and programmer s manual NI LabVIEW SignalExpress Tektronix Edition software Calibration Certificate documenting measurement traceability to National Metrology Institute s Z 540 1 Compliance and 1509001 power cord one year warranty Note Please specify power plug and manual language version when ordering Instrument Options Record Length Options Option DPO7054C DPO7254C DPO7104C DPO7354C Opt 2RL 125M max 25M ch 125M max 25M ch Opt 5RL 250M max 50M ch 250M max 50M ch Opt 10RL 500M max 125M ch Sample Rate Options Option DPO7104C DPO7054C DPO7254C DPO7354C Opt 2SR Double maximum real time sample rate to 40 20 10 GS s on 1 2 4 ch Solid State Hard Disk Drive Options Option Description Opt SSD Solid State Hard Disk Drive Digital Phosphor Oscilloscopes DPO7000C Series Software Options Option Description Opt DDRA 1 2 DDR Memory Bus Analysis Opt DJA Jitter and Eye Analysis Tools Advanced DPOJET Opt D PHY 1 3 MIPI D PHY Essentials Transmitter Debug Characterization and Compliance Test Solution Opt DVI 4 Digital Visual Interface Compliance Testing Opt ET3 5 Ethernet Compliance Testing Opt LSA Low speed Automotive Serial Analysis includes CAN Trigger CAN LIN Decode and Analysis Opt LT Waveform Limit Testing
41. sktop and clone mode Miniature phono jacks PS 2 compatible PS 2 compatible Front panel TekVPI connector Max input 150 V CAT Trigger Out A TTL compatible pulse when the oscilloscope triggers Time Base Reference Out A TTL compatible output of internal 10 MHz reference oscillator Time base system can phase lock to an external 10 MHz reference 10 MHz 1 BNC connector provides a buffered version of the Ch3 signal 50 mV div 20 into a 1 MQ load 25 mV div 20 into a 50 Q load Bandwidth is 100 MHz into a 50 Q load Front panel pins Amplitude 1 V 20 into a 250 Q load Frequency 1 kHz 5 Enabled by Opt MTM BNC connector lt 1 25 Gb s output swing 2130 mV into 50 Q Enabled by Opt MTM BNC connector 1 25 Gb s output swing 200 mV into 50 Q LAN eXtensions for Instrumentation LXI Characteristic Class Version Power Source Characteristic Power Source 16 www tektronix com Description LXI Class C V1 3 Description 100 to 240 V 10 47 to 63 Hz lt 550 W 115 Vams 10 360 to 440 Hz CAT I lt 500 VA Physical Characteristics Benchtop Configuration Dimension mm in Height 292 11 48 Width 451 17 75 Depth 265 10 44 Weight kg Ib Net 15 32 Shipping 28 9 63 75 Rackmount Configuration Dimension mm in Height 331 12 25 Width 479 18 85 Depth from rackmounting 231 75 9 12 ear to back of instrument Weight kg Ib Net 17 4 oT ee Rackmount Kit 25 5 5 Required Cooling Clearance Dimens
42. t gt lt lt Digits Export _ Clear Count Bring Zoom to Mark Zoom 2 Zoom 3 Search step 2 Advanced Search and Mark automatically searches through the record and marks each event with a solid colored triangle You can then use the Previous and Next buttons to jump from one event to the next User Marks Press the Set Clear front panel button to place one or more marks on the waveform Navigating between marks is as simple as pressing the Previous lt and Next buttons on the front panel Search Marks The Search button allows you to automatically search through your long acquisition looking for user defined events All occurrences of the event are highlighted with search marks and are easily navigated to using the front panel Previous lt and Next buttons Search types include edge glitch width timeout runt pattern state setup and hold transition and window File Edit Vertical Horiz Acq Trig Display Cursors leasure Mask Math MyScope Analyze Utilities Help B ie de nn oe ee Se polizia La Fe adal a mr GTP 500mV div 1MQ y 500M x ns div 1 0GS s 1 0ns pt Wa FastAcq Sample 25 594 786 acqs RL 1 0k Auto Digital phosphor technology enables greater than 250 000 wfm s waveform capture rate and real time color grading on the DPO7000C Series Digital Phosphor Technology The DPO7000C Series digital phosphor technology provides you
43. t 10BASE T 100BASE TX and 1000BASE T Option ET3 and USB 2 0 Option USB physical layer devices These software packages enable you to conduct testing using the standard s specified compliance tests Power Analysis Optional The optional power analysis software package Option PWR enables quick and accurate analysis of power quality switching loss harmonics magnetic measurements safe operating area SOA modulation ripple and slew rate di dt dv dt Automated repeatable power measurements are available with a touch of a button no external PC or complex software setup is required The package includes a report generation tool to create customizable detailed reports to document your measurement results Advanced Analysis Jitter Timing and Eye Diagram Measurements Optional The optional DPOJET Advanced software package Option DJA offers extended capabilities providing a complete suite of analysis tools for insight into jitter and timing as well as other signal quality issues DPOJET Advanced adds advanced tools such as Rj Dj separation eye diagram masks and Pass Fail limits for conformance testing The innovative Digital Phosphor Oscilloscopes DPO7000C Series File Edit Vertical Horiz Acq Trig Display Cursors Measure Mask Math MyScope Analyze Utilities Help B 5 0V div 50Q Ay 500M A JS 16 2V 5 0ms div 2 0MS s 500ns pt GTP 20 0mA div 1MQ 4y 120M Single Seq 115mW 5 0ms acqs RL 100k
44. t as a Boolean logic qualifier for the A and B events Serial Triggering and Analysis Optional On a serial bus a single signal often includes address control data and clock information This can make isolating events of interest difficult The DPO7000C Series offers a robust set of tools for debugging serial buses Digital Phosphor Oscilloscopes DPO7000C Series File Eat Vertical Digital HoriziAca Ts Display Cursors Measure Mask Math MyScope Analyze usiiies Help E C3 OUT A1 amp C3 OUT A2 amp C3 OUT A3 amp C3 OUT A4 amp C3 OUT A5 Eye Diagram triggering using optional Visual Trigger Addr4 EndP 2h CRC5 00n ci 2 0V div 1MQ By 500M D B1 Bus 100ps div 10 0GS s 100ps pt Cca 2 0V div 1MQ By 500M Single Seq 1 acqs RL 10 0M e 2 0V 500ns 3 98ps 1 02ps zica IPA 500ns 3 98ps 1 02ps Triggering on a specific OUT Token packet on a USB full speed serial bus A bus waveform provides decoded packet content including Start Sync PID Address End Point CRC Data values and Stop with automatic trigger and decode on 12C SPI RS 232 422 485 UART CAN LIN and USB 2 0 and decode for MIPI D PHY DSI 1 and CSI 2 serial buses Serial Triggering Trigger on packet content such as start of packet specific addresses specific data content unique identifiers etc on popular serial interfaces such as 2C SPI RS 232 422 485 UART CAN and USB 2 0 B
45. tek com products oscilloscopes floatinglicenses for additional P A information about floating license options Opt AS Switzerland Option Description Opt A6 Japan DPOFL DDRA 1 2 DDR Memory Bus Analysis Opt A10 China DPOFL DJA Jitter and Eye Analysis Tools Advanced DPOJET Opt A11 India DPOFL D PHY 1 3 MIPI D PHY Transmitter Debug Characterization and Opt A12 Brazil Compliance Test Solution Opt A99 No power cord DPOFL DVI 4 Digital Visual Interface Compliance Testing DPOFL ET3 5 Ethernet Compliance Testing i aoe a ee i M DPOFL LSA Low speed Automotive Serial Analysis includes CAN sad ante RHOR a Trigger CAN LIN Decode and Analysis Option Description DPOFL LT Waveform Limit Testing Opt LO English manual DPOFL MTM Mask Testing for ITU T ANSI T1 102 Ethernet Opt L1 French manual SONET SDH Fibre Channel USB 2 0 IEEE 1394b Opt L3 German manual Rapid I O OIF CPRI and Serial Video includes Oot L5 J hardware clock recovery on DPO7254C DPO7354C Be se eds DPOFL PWR Power Measurement and Analysis Opt L7 Ampe Canese manual DPOFL SR COMP Computer Serial Triggering and Analysis Opt L8 Traditional Chinese manual RS 232 422 485 UART Enables triggering on Opt L9 Korean manual packet level information on RS 232 422 485 UART Opt L10 Russian manual buses as well as analytical tools such as digital views of the signal bus views and packet decoding Opt L99 No user manual DPOFL SR CUST Custom Serial Analysis Kit for Developers DPOFL
46. ter or slower than specified Slope may be positive negative or either Trigger on violations of both setup time and hold time between clock and data present on any two input channels Trigger when pattern goes false or stays true for specified period of time 300 ps to 1 s Pattern AND OR NAND NOR specified for all analog input channels defined as high low or don t care Transition Setup Hold Logic Pattern Logic State Any logical pattern of channels 1 2 3 clocked by edge on channel 4 Trigger on rising or falling clock edge Parallel Bus Trigger on specified data value on defined parallel bus Video Trigger on all lines specific line number odd even or all fields on NTSC PAL SECAM and HDTV 480p 60 576p 50 8751 60 720p 30 720p 50 720p 60 1080 24sF 1080i 50 1080p 25 1080i 60 1080p 24 1080p 25 1080p 50 1080p 60 Bi level Tri level Visual Trigger Optional Provided as part of Opt VET Trigger on up to 8 user specified areas including rectangle triangle trapezoid and hexagon shapes Comm Optional Provided as part of Opt MTM Support for AMI HDB3 BnZS CMI MLT3 and NRZ encoded signals I2C Optional Provided as part of Opt SR EMBD Trigger on Start Repeated Start Stop Missing ACK Address 7 or 10 bit Data 1 5 bytes or Address and Data on 2C buses up to 10 Mb s Provided as part of Opt SR EMBD Trigger on SS or data 10 16 words on SPI buses up to 10 Mb s Provided as part of
47. that can be measured Sources Channel 1 Channel 2 Channel 3 Channel 4 Ref 1 Ref 2 Ref 3 Ref 4 Math 1 Math 2 Math 3 Math 4 Types Vertical Horizontal Waveform Processing Math Characteristic Description Number of Math Up to 4 Waveforms Arithmetic Add Subtract Multiply Divide waveforms and scalars Algebraic Expressions Define extensive algebraic expressions including waveforms scalars user adjustable variables and results of parametric measurements Perform math on math using complex equations e g Integral CH1 Mean CH1 x 1 414 x VAR Average Invert Integrate Differentiate Square Root Exponential Log10 Log Abs Ceiling Floor Min Max Sin Cos Tan ASin ACos ATan Sinh Cosh Tanh Math Functions Relational Boolean result of comparison gt lt 2 S Frequency Domain Spectral Magnitude and Phase Real and Imaginary Functions FFT Spectra FFT Vertical Units Magnitude Linear dB dBm Phase Degrees radians group delay Rectangular Hamming Hanning Kaiser Bessel Blackman Harris Gaussian Flattop2 Tek Exponential As an arbitrary math expression User definable filters Users specify a filter containing the coefficients of the filter Filter files provided A function that generates a waveform database pixmap from a sample waveform Sample count can be defined FFT Window Functions Waveform Definition Filtering Functions Mask Function Digital Phosphor
48. us Display Provides a higher level combined view of the individual signals clock data chip enable etc that make up your bus making it easy to identify where packets begin and end and identifying subpacket components such as address data identifier CRC etc www tektronix com 5 Data Sheet ip PI Token OUT Data DATAO Handshake NYET Token PING Handshake NAK Token PING Handshake NAK Config Display Event table showing decoded serial packet data in a long acquisition Bus Decoding Tired of having to visually inspect the waveform to count clocks determine if each bitis a 1 or a 0 combine bits into bytes and determine the hex value Let the oscilloscope do it for you Once you ve set up a bus the DPO7000C Series will decode each packet on the bus and display the value in hex binary decimal USB only or ASCII USB and RS 232 422 485 UART only in the bus waveform Event Table Display In addition to seeing decoded packet data on the bus waveform itself you can view all captured packets in a tabular view much like you would see in a software listing Packets are time stamped and listed consecutively with columns for each component Address Data etc Bus Searching Serial triggering is very useful for isolating the event of interest but once you ve captured it and need to analyze the surrounding data what do 6 www tektronix com Sync Scope to Selected Row Put M
49. with fast insight into the real operation of your device Its fast waveform capture rate greater than 250 000 wfm s gives you a high probability of quickly seeing the infrequent problems common in digital systems runt pulses glitches timing issues and more Waveforms are superimposed with one another and waveform points are color coded by frequency of occurrence This quickly highlights the events that occur more often over time or in the case of infrequent anomalies occur less often With the DPO7000C Series you can choose infinite persistence or variable persistence determining how long the previous waveform acquisitions stay on screen This allows you to determine how often an anomaly is occurring Visual Trigger Optional The Visual Trigger option adds an additional dimension to the standard trigger system that provides an intuitive method of triggering based on shapes in the oscilloscope s graticule It enables the user to define shapes on the oscilloscope s display that qualify trigger events for the incoming signals Areas can be created using a variety of shapes including triangles rectangles hexagons or trapezoids to fit the area to the particular trigger behavior desired Once shapes are created on the oscilloscope s display they can be positioned and or re sized dynamically while the oscilloscope is in Run mode to create ideal trigger conditions Visual Trigger can be combined with the standard triggers and ac