1.  N 6943300 Rev A Page 1 of 8       Figure 2  Optical module insertion in the EXT port    Step 3  Rackmount Installation    To mount the 9145 in a rack  carefully remove the four rubber feet located under the NID using a  small  flat screwdriver  Install the rack mount ears using the screws provided in the kit onto the  9145 chassis  Screw in three on each side of the NID using a Phillip   s head screw driver as  shown in Figure 3        Figure 3  Rackmount ear installed    When mounting the unit in a rack  be sure to accommodate at least IRU  1 75     of space in the  rack due to the height of the NID  See Figure 4        Figure 4  9145 installed in a rack    Canoga Perkins Corporation  20600 Prairie Street  Chatsworth  CA 91311 6008  Phone   818  718 6300  FAX  818  718 6312 www canoga com    P N 6943300 Rev A Page 2 of 8    Step 4  Applying Power   For AC powered NIDs  power up the device by inserting the provided power cord to an AC  outlet  During the boot up stage  which may take up to 20 seconds  the LEDs will turn amber and  the STA LED will flash until the boot up process is complete     For DC powered NIDs  if a  48VDC power source is used  connect the grounding strap between  the Chassis Ground and the  VDC terminals  If connecting to a  48VDC source to the NID   connect the grounding strap between the Chassis Ground and the  VDC terminals  With power  now applied  the unit will initiate the boot up process  All LEDs in the front will flash amber and  the STA LED wi
2. 600 Prairie Street  Chatsworth  CA 91311 6008  Phone   818  718 6300  FAX  818  718 6312 www canoga com  P N 6943300 Rev A Page 3 of 8    Assign an icon and a name for the session            gt  New Connection   HyperTerminal   d   j  l0  x     File Edit Yiew Call Transfer Help       ols 6 3  ala       i  wy New Connection    Enter a name and choose an icon for the connection     Name      3145 NIDI    Cancel                N ie    Disconnected Auto detect Auto detect SCROLL CAPS  NUM  Capture Print echo  Figure 7  Connection Properties    After a name and icon is assigned  the COM port properties menu will appear  Configure the  connection settings to the values listed     Bits per second  9600bps  Data bits  8   Parity  None   Stop bits  1   Flow control  None    If the HyperTerminal screen is scrolling up  make sure that    Terminal Emulation    in the  Properties menu is set to VT100  If the screen shows random symbols instead of letters  verify  that the terminal speed is set to 9600bps     Step 6  Logging In    In the log in screen  type the default Username    admin    and Password    admin    to access the user  interface  The MAIN MENU will appear and will allow you to make necessary configuration  changes based on your selection  Refer to the user manual for more detailed information     Canoga Perkins Corporation  20600 Prairie Street  Chatsworth  CA 91311 6008  Phone   818  718 6300  FAX  818  718 6312 www canoga com    P N 6943300 Rev A Page 4 of 8    Canoga Perk
3. F76 01 24 34                                     FUNCTIONAL CONFIGURATION                                      Local Remote  Offline    User Port Speed Duplex Link Down  Ext Port Speed Duplex Link Down    1  User Port Setting  2  Ext Port Setting Autonegotiate  3  RMTF Disabled  4  Link Loss Fwd Disabled  5  Flow Control Disabled  6  PVST  BPDU Filtering Disabled    7  Sideband Management Disabled    Hit SPACE  toggle selection  ENTER  accept  ESC  cancel     Figure 10  Functional Configuration screen    Module Type  Settings    10 100 1000 UTP Autonegotiate  Disable  10M Half Duplex  10M Full Duplex  100M Half Duplex  100M Full Duplex  1000M Half Duplex  1000M Full Duplex  10Mbps Optical Disable  10M Half Duplex  10M Full Duplex  100Mbps Optical Disable  100M Half Duplex  100M Full Duplex  1000Mbps Optical Autonegotiate  Disable  1000M Half Duplex  1000M Full Duplex       Table 1  Module type and settings    Canoga Perkins Corporation  20600 Prairie Street  Chatsworth  CA 91311 6008  Phone   818  718 6300  FAX  818  718 6312 www canoga com  P N 6943300 Rev A Page 6 of 8    Step 7  Cable Connection   Once the desired changes are made to the modules  the UTP or fiber optic cables can be installed   A Category 5 UTP cable can now be installed from the 10 100 1000Mbps UTP module to your  switch  Canoga Perkins recommends at Category 5e UTP cable or better for 1000BaseT  installations  Remember that the USR port is the port connected to your local client device and  the EXT port 
4. ION                                    Local Remote  Offline  MAC Address 00 40 2A 00 9B 80  Management Port DOWN  1  Ethernet IP Address 000 000 000 000  Subnet Mask 255 255 255 000  Default Gateway 000 000 000 000  2  Inband Management Port Both Ports    3  Management VLAN Tagging Disabled  4  Management VLAN Number 1    5  SLIP PPP IP Address 000 000 000 000  6  Serial Port Config VT100   7  BOOTP Disabled   8  Telnet Security Disabled   9  Host Table   10  Trap Table    Select  1 10   1    Figure 13  IP SNMP Agent Configuration screen    This concludes the initial set up of the 9145 NID  For detailed information on other functions of  the 9145 NID  consult the user manual or contact Canoga Perkins    Tech Support line at  818     718 6300     Canoga Perkins Corporation  20600 Prairie Street  Chatsworth  CA 91311 6008  Phone   818  718 6300  FAX  818  718 6312 www canoga com    P N 6943300 Rev A Page 8 of 8    
5. Quick Start Guide  9145 NID    Overview  This document provides instructions for installation and initial configuration of the Canoga  Perkins model 9145 NID  Network Interface Device      Parts List   1 x 9145 4  AC power  or 9145 5  DC power    1 x User  USR  port interface module  typically a UTP module  but can also be an optical  module    1 x Extension  EXT  port interface module  typically an optical module    1 x Set of 19    or 23    optional rack mount ears   1 x AC power cord    Tools Required  1 x EIA 232 DB 9 cable  not included     1 x Phillips flat screwdriver  if mounting in a relay rack     step 1  Unpacking  Unpack the 9145 and check the unit for damage  Ifthe unit is damaged  contact Canoga Perkins       Tech Support line   800  360 6642  and ask for an RMA     step 2  Module Insertion  It is very likely that the USR and EXT ports are already occupied by the correct interfaces for the    application from the factory  However  if the interfaces are ordered separately  follow the next  steps to configure the modules     Insert the user interface module in the USR port slot of the NID  The module should slide into  the slot with ease and make contact with the rear connector without excessive force  Tighten the  thumbscrew and do the same for the EXT port        Figure 1  10 100 1000Base T UTP module insertion in USR port    Canoga Perkins Corporation  20600 Prairie Street  Chatsworth  CA 91311 6008  Phone   818  718 6300  FAX  818  718 6312 www canoga com    P
6. ins Corp  Ethernet Network Interface Device 06 Jan 1970  Model 9145 4 V03 40 F76 04 11 30    Please Enter Login Username   admin  Please Enter Login Password            Figure 8  Log In screen    Canoga Perkins Corp  Ethernet Network Interface Device 06 Jan 1970  Model 9145 4 V03 40 F76 04 11 40    1  System Configuration   2  Diagnostics   3  Link Status   4  System Alarms   5  Layer 2 Statistics   6  RMON Group 1 Statistics  7  System Log   8  Utilities   9  Software Upgrade   10  Manage Logged In Users  11  Logout    Select  1 11      Figure 9  Main Menu screen    Step 7  Module Configuration    From the Main Menu  type    1     enter  then    2     enter  to access the Functional Configuration  screen  The Functional Configuration screen will allow you to change the settings of the USR  and EXT port modules  and Table 1 lists the modules available for the NID and their respective  settings  Verify the link speed and duplex of the local and remote device and change the settings  of the modules accordingly     To change the settings  type the number of the setting you wish to change and use the space bar to  toggle through the selections  Use the ESC key to cancel your selection or to return to the earlier  screen     Canoga Perkins Corporation  20600 Prairie Street  Chatsworth  CA 91311 6008  Phone   818  718 6300  FAX  818  718 6312 www canoga com    P N 6943300 Rev A Page 5 of 8    Canoga Perkins Corp  Ethernet Network Interface Device 07 Jan 1970    Model 9145 4 V03 40 
7. is the port facing the network trunk  Connect the fiber to the optical module         T   PERKINS K  O  Oo Tx    iQ Rx       From Tx of Remote Device    To Rx of Remote Device  Figure 11  Fiber optic cable connection    step 8  IP Address Subnet Mask Default Gateway Set u  From the System Configuration menu  type    5    then    enter    to access the IP VLAN  Configuration screen        Canoga Perkins Corp  Ethernet Network Interface Device 07 Jan 1970  Model 9145 4 V03 40 F76 01 24 34    1  Hardware Information   2  Functional Configuration   3  VLAN Configuration   4  VLAN P Bit Translation Tables  5  IP SNMP Agent Configuration  6  Trap Configuration   7  Security Configuration   8  Account Configuration   9  System Info Configuration    Select  1 9   5    Figure 12  System Configuration screen    To configure the IP address  select    5     press enter  and type the IP address you wish to assign to  the unit  Press enter to accept the changes  The Subnet Mask and Default Gateway must be  entered at this point as well  and note that the Subnet Mask and Default Gateway must be in the  same class as the IP address  i e  Class A  Class B or Class C     Canoga Perkins Corporation  20600 Prairie Street  Chatsworth  CA 91311 6008  Phone   818  718 6300  FAX  818  718 6312 www canoga com  P N 6943300 Rev A Page 7 of 8    Canoga Perkins Corp  Ethernet Network Interface Device 07 Jan 1970    Model 9145 4 V03 40 F76 01 24 34                                  IP SNMP AGENT CONFIGURAT
8. ll flash until the boot up process is complete         a           Figure 5  DC power entry in the rear of the NID    Step 5  Management Access   To access the user interface of the NID  a VT100 session must be created through HyperTerminal  or a comparable VT100 terminal  Connect a DB 9 EJA 232  straight cable from your PC or  laptop  COM lor any open COM port  to the EIA 232 port of the NID  Access HyperTerminal  session from your laptop or terminal through the  Programs Accessories Communications Hyperterminal menu            ai Burn CD  amp  DYDs with Roxio    At g  i   New Office Document H a       ocument VER  Query    a Open Office Document    C7 Set Program Access and Defaults LA   w    H     xCe Wor  cae Windows Catalog Excel ard  up  gt     nternet login  txt  pions       t Windows Update  g Winzip    DeBerry        E                    fam System Tools  F    a Programs z  Canogaview Smart Element Manager Standalone m Ea HyperTerminal  Eg Documents H IT ROT Personal workstation    Network Connections       ee    S               F a a In Spybot   Search  amp  Destroy 9 Network Setup Wizard     Settings   o   in TFTF Server New Connection Wizard   ny ye Search m Trend Micro OfficeScan Client a Remote Desktop Connection  s     Ee  ScreenPrint Gold 2 5   Wireless Network Setup wizard     2  Help and Support f HyperTerminal    x J  Run     i SS             Undock Computer          Shut Down    arteak    F igure 6  Accessing HyperTerminal    Canoga Perkins Corporation  20
    