Home
c2e User Manual - ITR of Georgia
Contents
1. Figure 7b Entering Channel Data Pulse Only Screen Frequency Enter a frequency at the Frequency prompt To remove or zero a programmed frequency see section titled Removing Existing Frequencies Note Atleast three digits after the decimal point must be entered into the frequency space 25 e Mode Select the channel Mode by entering one of the following C Carrier only operation P PL tone activation D DPL code activation e Code Enter the DPL or PL coding that are supplied by the public safety agency The DPL and PL coding can also be auto loaded by selecting PL DPL Code 0 If auto load is selected be sure to have the public safety agency test the unit for proper operation Note When entering a DPL Code you must add a D prior to the number as shown in Figure 7a above For PL codes just enter the number without a preceding letter e Gain The base setting for Gain varies with each production run Range settings typically run between 30 amp 100 When increasing or decreasing range stepping 2 to 3 increments at a time is recommended The units default setting for gain is 100 See table 1 for base gain settings e Momentary gate relay Y N Enter the length of time the gate will stay open before it automatically closes This feature is defaulted to the ON position and 01 MIN Thus if you select N to the Momentary gate relay you will be asked to choose one of the three following time modes 1
2. A chart to assist you in assigning an arbitrary distance setting of 10 feet for installations in the field is located in Table 1 below This is a guide for you to set the general distance based on the frequency range of a 4W portable radio operating on the individual channel of assignment These settings were made in optimal conditions The values in your application may vary The base range settings are not absolute The settings in Table 1 were obtained using a 4W portable unit at a distance of 10 feet Note For VHF low a 5W radio was used Should the Click2Enter not activate at a reasonable distance or be too sensitive causing spurious activation to occur you may want to change these settings Table 1 Click2Enter I Gain Ranging Base Settings Portable Radio Frequency Frequency Used aad a ES VHF Low 5W Radio 51 0000 MHz 75 VHF High 4W Radio 154 445 MHz 90 UHF Low 4W Radio 464 500 MHz 85 UHF High 4W Radio 853 150 MHz 88 The data in this table is based on a 20 foot operating range 1 Each lot shipment of Click2Enter l is specifically calibrated for its own unique gain range settings The Gain Range column in Table 1 shows these base settings Each production run may be different so always match the data in this table to the unit it was shipped with The GAIN or RANGE setting feature of the C2E I is based on a logarithmic scale not linear scale What this means is that the settings change dramatically w
3. We recommend assigning a separate frequency and channel to be used with portable radios if the portable radios might be ignored based on the operational range of the mobile It is desirable to use the portables in conjunction with the mobiles Assigning the portable units their own channel will allow greater control over the range of the Click2Enter I Remember that if the higher power mobile accesses the portable unit s different channel it may open the gate at a further distance thus causing an accidental or spurious activation or opening 13 Option Relay The option relay is provided for the installer user so they can activate other devices when the this relay is enabled This relay provides a short one time 50mSec contact which can be used for a multitude of things For example if there is an alarm at the residential or commercial site the installer could assign a circuit loop from the security alarm system to the option relay contacts This would activate the alarm whenever the Click2Enter I was activated adding an increased security potential to the system Another feature of the second relay is realized when the Dual Relay mode is enabled When this function is enabled each of the two relays operates independently of each other Thus two separate devices can be controlled with two separate frequency assignments This feature is highly desirable in roll up door applications Installation of the Click2Enter 1 OPE
4. on the Click2Enter l is used for an optional relay You can then run wires to any low voltage load up to 1 amp that you wish to key This relay does not have a timed function If you need a timed relay for your auxiliary devices you must install a timer circuit CAUTION Damage may occur to C2E relays from systems using relays that deliver a high counter EMF Click2Enter can ONLY accommodate micro volt systems Call for an isolation relay kit to protect C2E in high counter EMF applications see product specifications at the end of this manual Note The Click2Enter I will not activate when power 1 to the operator has failed This condition will be shown by no visible Green power LED Hook up the power by connecting the Click2Enter l terminal block Power in DC to a transformer rated at 12V DC to 24V DC Y 500mA Set the operator to open automatically during a power failure situation Once power is restored the gate and C2E I will return back to normal operation Battery back up systems have two modes of operation e Open and hold open when there is a power failure Install Click2Enter l as recommended above e Remains closed and opens when the radio control device has given the signal to open It will stay open until the power comes back on NOTE This mode is NOT recommend by Click2Enter Inc 15 TIP USING SMALL DIAMETER WIRE OVER LONG DISTANCES CAN EFFECT UNIT OPERATION ALWAYS CONSIDER AWG
5. x 6 x 4 HWD Weight 2 9 lbs 29 7 Click2Enter Inc Limited Warranty Click2Enter Inc Click2Enter warrants the Click2Enter Product only to be free from defects in material and workmanship under normal use and service for a period of either one year after the date of purchase by the original customer or eighteen months from date of factory shipment at the discretion of Click2Enter Inc Click2Enter s sole obligation under this warranty is limited to repairing or replacing at our discretion any parts which shall be determined by Click2Enter to be defective and is conditioned upon the original customer giving notice of any such defect to Click2Enter within the warranty period Click2Enter reserves the sole right to make the final decision whether there is a defect in materials and or workmanship and whether or not the product is within the warranty period Click2Enter is not responsible for any damages or other cost s proximately caused by or which may result from installation handling non recommended operation abuse or modifications not authorized by Click2Enter for any damages which may arise out of use of the Product This warranty shall not apply to any Click2Enter product which has been subject to misuse neglect accident or to use in violation of instructions furnished including improper installation or connection to an improper voltage source or products damaged by Acts of God lightning strikes powe
6. Relay Gate Relay Assignable pulse on or timed hold open Used to supply power polarity not Power IN DC Power Input required to the C2E l 12V DC to 24V DC 500mA Password Access Battery The Click2Enter I comes with a built in five year manganese dioxide lithium battery This battery backs up the time date and history memory register It should be replaced every 5 years Test button The test button toggles the unit to a test bank of frequencies so the installer can operate the system to receive radio signals Once the test button is pressed the power LED will blink to indicate test mode is active and for approximately three minutes the unit will activate with any of the frequencies programmed into this bank Once test mode times out the Click2Enter will revert back to using the programmed operations channels in the main bank of frequencies RS 232 serial port The RS 232 serial port connects the Click2Enter l to a computer for programming purposes Access to the Click2Enter l programming mode is protected by three levels of passwords The initial passwords are set when the unit is powered up for the first time The default values for the unit are e Level 1 123456 e Level 2 234567 Level 1 is the lowest level and is used primarily by installers and other field personnel Level 2 is intended for use by distributors or other wider use 18 Test Mode For example the level 2 password m
7. X This command exits from the programming mode access to the Click2Enter I The maintenance mode terminates automatically if no commands are entered within approximately three minutes Y This command is for Click2Enter Inc use only Z This command erases all channels 28 6 Specifications Memory Channels Main Bank 50 Test Bank 50 Spurious Rejection FM at 154 MHz 40 dB Selectivity 10 KHz 6 dB 18 KHz 50 dB IF Interference Ratio 257 5 MHz at 154 MHz 50 dB 21 4 MHz at 154 MHZ 100 dB Scanning Rate 25 channels sec IF Frequencies 257 5 MHz 21 4 MHz and 455 MHz Current Demand Nominal Conditions 198 mA at idle 10 268 mA during activation with large LED in ON condition and gate relay in latch condition Frequency Coverage Frequency Step Mode 29 54 MHz 5 KHz FM 137 174 MHz 5 KHz FM 380 512 MHz 12 5 KHz FM 806 960 MHz 12 5 KHz FM Aircraft AM Bands Covered Max Current at Relay Gate 1A Option 1A Working Voltage 50V DC MAX CAUTION Damage may occur to C2E relays from systems using relays that deliver a high counter EMF Click2Enter can ONLY accommodate micro volt systems Call for an isolation relay kit to protect C2E in high counter EMF applications Power Requirement 12V DC to 24V DC 500 mA Operating Temperature 10 C to 60 C or 14 F to 140 F Dimensions 6
8. activations Note It should be noted that the C2E I default gain setting is 100 Greater distances of operation can be achieved by setting the unit gain above 100 Any gain setting beyond line of sight is considered a dangerous situation potentially increasing the likelihood of accidental or unwanted activations of the system The gain can be set from 0 to 255 The actual gain swing typically programmed will be between 30 and 100 Most systems operate well within the gain setting of 40 to 90 This typically allows for operational ranges of mobile radios between 80 Ft to 150 Ft Warning To protect the lives of people and pets as well as to prevent property damage do not set the gain to a level that allows for the operation of the gate beyond the line of sight A Personal Digital Assistant can be used to program the Click2Enter l using terminal emulator software and null modem adaptor Visit our web site at www click2enter net or call 877 939 3800 to learn more about this feature 21 Logging On to the Unit During Initial Power Up During Normal Operation 6 Programming Once the appropriate DC power is applied to the unit check to be certain that the Power LED Green is operational If confirmed ON move onto the next step To access the Click2Enter l programming mode Connect a PC or serial enabled palm top to the Click2Enter serial port using a standard 9 pin male to female straight through serial
9. s BETWEEN 14 AWG TO 16 AWG Note Consult your gate operator manufacturer for proper installation for battery back up systems 2 Exterior battery back up system This is usually an inverter type system providing 110 VAC to the gate operator With this type of system you may connect the Click2Enter I in the same manner as if there were no battery back up system Caution Remember that in the case of the built in battery back up system there is no safety function during the power failure mode of operation Therefore the Click2Enter l must be used only when the gate is visible and there are no obstructions or people present Never bypass or disable any of the manufacturer gate safety systems or those required under the UL325 guidelines Review of activation terminals e Elite and Sentex Operators Use fire switch terminal and common e DoorKing Use keying terminals such as 11 and common e FAAC 401MPS Use terminals 1 and 2 for key and break and terminals 8 and 9 for hold open e Battery back up for built in units use normal DC transformer installation Final Comments Regarding 62E 1 Power Requirements The C2E l experiences significant problems with AC line noise that is passed into the radio receiver of the device In some frequency bands the C2E I can lock on a false noise signal which is not desirable To provide optimal operation of the system ONLY use a 12V DC to 24V DC any step Regulated amp Filtered
10. 0 02 462 6125 74 4 1 Min 80 03 462 6375 77 0 2 Min 80 04 462 6625 79 7 0 Min 80 05 462 6875 82 5 1 Min 80 06 462 7125 85 4 2 Min 80 Z lt Z lt Z lt Z Z Z 2 Z2 Z Z NM NM NM 19 5 Programming Overview Programming the Click2Enter 1 TIP VISIT OUR WEBSITE TO SEE HOW TO DOWNLOAD A COPY OF HYPER TERMINAL Adding Frequencies to the Click2Enter 1 Having multiple user programmability answers the mutual aid problem that presently exists with other emergency access control products The Click2Enter l is capable of operating with the most commonly used frequencies used by public safety agencies See Specifications section for more information Note As an added feature any standard radio s frequency and tone PL or DPL may be entered into the Click2Enter I to allow property owners with their own commercial radios to open the gate Any terminal emulator such as HyperTerminal can be used to program the unit If HyperTerminal is not installed with your MS Windows computer it can be obtained from our website 1 Click Settings gt Control Panel from the Start menu Click Add Remove Programs Click the Windows Setup tab Double Click Communications from the component menu Select the HyperTerminal checkbox 6 Click OK Note See Logging Onto The Unit for HyperTerminal sett
11. 500mA power source ALWAYS use a good quality surge protector to protect the C2E I from unwanted voltage spikes 16 4 Configuration Overview The Click2Enter l is simple to configure The door on the waterproof case can be opened by unscrewing the security screws Once the door to the Click2Enter l is open Serial Connect Gate and Option Relays and test button D can be accessed PowerLED Activation LED Do Not Touch Serial Connect PA Battery xw sOption B Relay Test Button A Gateq A Relay Power IN DC 5 Figure 2 The Click2Enter I System Board Caution DO NOT adjust the volume and squelch knobs shown in Figure 2 Do Not touch Both of these knobs are set at the factory and adjusting them will effect the squelch and will adversely effect the performance of the Click2Enter l Enclosure Door Tightening Recommendations The enclosure is rated as a NEMA 4X When tightening the security screws to secure the door DO NOT over tighten The best gauge to use when tightening the security screws is to tighten the screws so you can slide a standard thickness business card between the door lid and enclosure base Do not tighten so that the enclosure door and box base touch 17 Terminal Connection Table 2 Terminal Input Connections Connection Type Description Option B Relay Option Relay Pulse on dry contact Normally open relay Normally open dry contact relay Gate A
12. IN LIEU OF ANY OTHER OBLIGATIONS OR LIABILITIES ON THE PART OF CLICK2ENTER ACCORDINGLY CLICK2ENTER ASSUMES NO LIABILITY OR OBLIGATION WHATSOEVER IN THE SALE OF THIS PRODUCT INCLUDING ANY LIABILITY FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES TO YOU OR ANY OTHER PERSON PROPERTY OR ENTITY RESULTING FROM THE USE OR POSSESSION THEREOF OUR MAXIMUM AGGREGATE LIABILITY TO YOU SHALL NOT EXCEED THE AMOUNT PAID BY YOU FOR THE PRODUCT THE LIMITATIONS IN THIS SECTION SHALL APPLY WHETHER OR NOT THE ALLEGED BREACH OR DEFAULT IS A BREACH OF A FUNDAMENTAL CONDITION OR TERM OR A FUNDAMENTAL BREACH WARRANTIES IMPLIED BY LAW ARE LIMITED IN DURATION TO THE ONE YEAR PERIOD DESCRIBED ABOVE This warranty gives you specific legal rights and you may have other rights which vary from state to state Some states do not allow limitations on how long an implied warranty lasts and some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitations or exclusions may not apply to you 30
13. M Gate open minutes 1 59 2 H Gate open hours 1 15 3 S Gate stays open unit must be reset to close If this feature is selected the unit will hold the gate open indefinitely To reset either open the unit and push the TEST button and the unit will reset in approximately 3 min or turn the system power OFF and this will reset to normal operation e Latch open amp hold Y N Enter Y at the Wait For Close prompt to enable the C2E l to hold the gate open When activated the C2E I will not allow an override closure it will defer to the countdown timer While enabled in this mode the C2E I will not accept another activation request The Activation LED will blink at a 50 duty cycle during the pre set time period 26 e Option Control Y N Enter Y at the Option Control prompt to enable the option relay For more information on the option relay see section titled Option Relay e Single pulse mode Y N The C2E l is defaulted to the double pulse mode To enable the single pulse mode answer Y in the assigned space The following message appears You are about to change the operation of this unit from double pulse to single pulse activation mode Accidental activation is more likely in this mode Proceed Y default G This command changes the state of the Gate relay for testing purposes allowing field service personnel to check the wiring of the Gate relay activates relay H This command lis
14. Power LED lt M Activation LED Click2Enter l Operator s Installer s Guide Version 3 0 Software Version 1 17 you re in FCC Information This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation In accordance with FCC requirements changes or modifications not expressly approved by Click2Enter Inc could void the user s authority to operate this product CAUTION Scanning is a great pastime You can listen to exchanges between police fire departments ambulances military organizations government agencies private companies aircraft and amateur radio stations Owning and operating this scanner is legal in so far as you do not intentionally intercept the following electronic and wire communications Cellular cordless or private telephone conversations transmit communications through means or telephone signal transmissions Pager transmissions Scrambles of encrypted transmissions As amended the Federal Electronics Communications Privacy Act ECPA states you could be fined and or imprisoned for intentionally listening to using or disclosing the contents of such a transmission unless a party in the communication has consented unless such and activity is otherwise legal In some areas
15. RATORS WITHOUT BATTERY BACKUP Install the Click2Enter l where the top and bottom LED lights and the reflective sticker can be seen Also note that the logo is reflective for night identification so mount the Click2Enter l in a visible location 1 Install two wires from the appropriate transformer to the power terminals Use the Power In DC block 12 24 V DC 500 mA power The Click2Enter I uses 198 mA in resting state and 268 mA in the latch state with applied 12V DC 2 Install the two wires from terminal block Gate A gate operation on the Click2Enter I to the keying relay terminal and the common terminal The proper location on the operator terminal strip will be designated by the manufacturer s instructions This device needs to be set up as a keying and hold open function The Click2Enter I should be connected to a fire switch terminal NEVER connect the Click2Enter l to safety or auxiliary terminals Note In some cases such as with the FAAC 401 MPS control panel install two wires to the keying function and two wires to break the reversing terminals 14 OPERATORS WITH BATTERY BACK UP BUILT IN The Elite and Sentex operators should use the fire switch terminal and the common DoorKing should use the key terminal This is usually 11 and common Note Be sure to check with your manufacturer instructions to identify proper terminals for hold open activation 3 Terminal block Option B
16. ature enables the Click2Enter I sub audible PL private line code to be auto detected and auto loaded The installer programmer can choose to enable the auto load feature or can manually assign the PL code Click2Enter I stores a running activation log in memory for operator recall The Click2Enter l system allows access by any public safety agency or authorized users as long as a frequency they use is programmed into its memory Activation Sequence The entire activation sequence takes less than four seconds The operator can either be on foot and using a portable radio or in a moving vehicle using portable or mobile radio NOTE Most agencies prefer the SINGLE Pulse Mode over the DOUBLE Pulse Mode Double Pulse Mode Approach the C2E I unit then 1 Hold the push to talk button until the activation light illuminates When the light shuts off release the push to talk button When the activation light illuminates again hold the push to talk button again until the light shuts off 4 When the light goes out release the button 5 The light blinks and the gate opens and or the security system deactivates 2 3 Single Pulse Mode Approach the C2E I unit then 1 Hold the push to talk button until the activation light illuminates 2 When the light shuts off release the push to talk button 3 The light blinks and the gate opens and or the security system deactivates Click2Enter A ctivation Sequence Hold mic
17. ay be the same for all units sold for system wide entry in a particular region or city However the level 1 password would be set to a unique value for individual unit access If the other two passwords are lost Click2Enter Inc can access the unit through a factory override password If this is necessary please contact Click2Enter at 877 939 3800 Passwords can be from 1 to 15 characters in length Level 1 must begin with the number 1 and level 2 must begin with the number 2 as shown above The Click2Enter has a special test mode feature Test mode can be activated by pressing the button on the Click2Enter l or selecting the test mode command from the programming interface Once activated the power LED will blink until the unit returns to normal mode after approximately three minutes via test button activation or indefinitely via computer programming mode key command T Table 3 shows the frequencies which we have pre programmed for you to use during test mode You can also enter your own user defined test frequencies in any of the 50 available channel memories 00 through 06 have been pre assigned by the factory using the Family Radio Service frequencies Any of those channels can be re programmed as needed Table 3 Pre Loaded Test Channel Memory CH PL Gate Wait to Frequency Code Hold Gain Opt Close Pulse 00 462 5625 None 0 Min 80 01 462 5875 None 0 Min 8
18. button on radio Hold down mic button until ight on scanner goes on second time after light goes on Release button when light goes off Release button when light goes off pi oching lightneans gate isi open 15 second 15_ second A E i A sidi edsecona A Bi LED Blinking Red LED Solid Red LED Error checking window Any constant carrier transmission or pulsed carrier transmission received in this window will reset the C2E 1 to scanning again it will not allow an activation Figure 1 Double Pulse Activation Diagram Note The activation light will blink while the gate is being opened If the gate does not begin to open once the activation light begins to blink it is recommended that the Click2Enter I be allowed to reset then retry the activation sequence shown above If the Click2Enter still fails to activate the gate while the activation light is blinking a decision to open the gate by force or by using other systems devices will have to be made Training Supplement Click2Enter Inc offers technical training support via our web site for the activation sequence Contact us for instructions access the simulator 7 Initial System Setup Guidelines TIP SINGLE PULSE OPERATION MOST WIDLEY USED Items for the public safety official to consider when gathering information to be programmed into the Click2Enter I C2E emergency access control units being deployed in your city county or region global programmi
19. cable NULL MODEM will not work 2 Run a terminal emulator such as Microsoft Windows HyperTerminal HyperTerminal is found by Clicking on the START button Then locate ACCESSORIES Then COMMUNICATIONS Then activate HyperTerminal Then assign a NEW connection 3 The Click2Enter operates at 9600 bps Eight data bits No Parity One stop bit Xon Xoff Flow control Select APPLY then OK 4 Press the Enter key to initiate the final handshake Note The unit will not display anything on the terminal program until you press the Enter key Also if you save your initial session and assign a desktop icon you will not have to set up HyperTerminal each time you want to log onto a C2E l to program it 5 Enter the password as shown below For default password see section titled Password Access 22 Click2Enter tm V1 17 C2E 1 0 S N APPEARS HERE Copyright C 2000 2007 Click2Enter Inc Sonoma CA U S Patent number 5 903 216 and 5 955 947 European Patent Number EP0956412 Germany Patent Number D B P 69729321 1 Canadian Patent Number 2 275 189 Password Type password here Password does not appear on screen Figure 4 The Program Screen Login Prompt Note When the programmer leaves Click2Enter l idle for approximately three minutes a time out feature causes the unit to default to asking for the re entry of the assigned password If you enter the password correctly the maintenance command prompt
20. e C2E does not mean that you lose the ability to continue to use it for communication purposes This just means that the user s of the system will know what channel to select in order to operate any C2E deployed in your city county or region Since the C2E can manage up to 50 different frequency assignments you can generally setup your system to accommodate many different channels agencies Mutual aid agencies should be considered in your basic set of allocated activation frequencies to include Fire EMS Sheriff Police Regional Fire Public Works etc e Ina standard radio system you might consider allocating a main repeat carrier and another direct non repeat frequency This would support routine and non routine activations of the C2E e The C2E requires the use of TRANSMIT TX not receive RX carrier frequency e Private Line PL or Digital Private Line DPL coding The C2E can accommodate either a PL or DPL code assigned along with your selected operational activation frequency These codes offer a little more specific selectivity and enhanced security however they are not mandatory Be aware that most public safety agencies opt not to allocate them as the level of operational security provided by the carrier frequency is clearly acceptable for gate activation Latch Back Consideration should be given to whether or not you want the C2E to hold open the gate for a pre set period of time to support the arrival
21. er l and expand its upper limit temperature range Minimum Range 14 F The low end operations of the Click2Enter l is 14 F For installations that may subject the Click2Enter I to a temperature range below this limit you may purchase an after market retrofit heater kit from Click2Enter Inc The heater retrofit kit will allow operations well below O F It is highly recommended that the Click2Enter be mounted so that the operator can clearly see the operation LED and power LED Both of these LED s provide important feedback to the operator Also Click2Enter I has a reflective logo on its front panel to assist in immediate identification during night use The C2E I can be mounted on a post placing it out of reach in areas prone to vandalism Another mounting location can be behind the gate thus keeping it out of reach Note The C2E I needs to be seen to be operated The C2E l plastic box comes with four mounting brackets We suggest that you use security head screws or bolts when mounting the unit to prevent theft The bottom pre drilled conduit hole supports connectors For projects that require a more low profile approach the C2E I can be mounted out of sight and a smaller external LED Activation box kit can be used Call your Wholesaler Dealer or Click2Enter Inc to ask about this additional kit 11 Distance Ranges The operational activation range of the Click2Enter can be configured in many different ways
22. f jurisdiction for purposes of assigning their own system wide point of access This system wide access facilitates access to any unit in the field by a representative of the agency of jurisdiction to make changes to the C2E or allow access to the stored data The Click2Enter l is designed to operate most efficiently with the transmitting radio oriented in the upright position vertical radio antenna The range and effectiveness of the radio will be greatly altered in any other configuration Note The Click2Enter I will operate with a portable radio oriented in either the vertical or horizontal plane however the base range setting of 10 feet was set holding the radio vertically If the radio is held horizontally the base range setting will be increased to 15 feet WARNING Do not drill holes into the enclosure or in any way modify the NEMA 4x box this will VOID your warranty 10 3 Installation Temperature Range Mounting Click2Enter I has a minimum and maximum operating temperature specification Maximum Range 140 F For most high temperature applications the maximum rated temperature of the unit is 140 F For best operation mount the unit in a location where it is shaded from direct sunlight Should it be necessary to mount the unit in the direct sun you may purchase an after market sun bonnet retrofit device from Click2Enter Inc You may also add your own shade device to adequately shade the Click2Ent
23. ings Note MS VISTA no longer supports Hyper Terminal 1 Once the necessary frequency and other operational information has been obtained from the public safety agencies for the region or city of operation base range settings can be obtained from Table 1 see section Initial System Setup Guidelines 2 Connect and log in to the Click2Enter I using a standard male to female serial cable and a terminal emulator program See the section titled Logging On to the Unit Type E at the C2E gt prompt and enter the frequency data 20 Removing Existing Frequencies Gain Settings Programming with a Personal Digital Assistant If you need to remove a frequency from the Click2Enter l you must zero out the frequency from the assigned channel 1 Enter the Click2Enter I setup program See section titled Logging On to the Unit and select E Enter Channel Data 2 Enter the Channel number at the Channel prompt 3 Use the Backspace key to remove the entire frequency data including the leading space at the frequency prompt 4 Enter 0 and press Enter the setup program will then clear the channel of all data The gain must be set while entering the frequency into the unit The gain setting allows the programmer to set the range of operation by adjusting the unit sensitivity When programming the gain setting always adjust to the minimum distance necessary for your application to pre vent unwanted
24. ith each numerical step The C2E I will accept numbers from 0 to 255 however the actual functional or operational range will be somewhere between 50 on the low end to 100 on the high end The default GAIN setting that each unit begins with is 100 Once the initial starting point for the GAIN RANGE is established it is recommended that increasing or decreasing the range should be in steps of 2 or 3 12 Power Output Another installation concept to consider is the lower power output of the hand held portable radio compared to the higher output power of the mobile transmitter radio Should activation of the unit only be required via the hand held portable then it is acceptable to set the operational activation distance to that particular unit If both portable and mobile radios are to be used set the operation range of the portable radio first then test the mobile s range It is recommended that you never enable the portable handheld transmitter to operate at a range greater than the 20 feet based on the settings shown in Table 1 In some applications due to radio wave propagation the portable will not work at the same distance ratio as the mobile In most applications if the mobile radio operates at a setting of 100 feet then the portable should operate at a range of 10 feet These are arbitrary numbers however they show the operational difference between the two different power outputs of units working off of the same frequency
25. ng data 1 2 Activation Pulse Mode Either Single Pulse or Double Pulse The C2E can operate in either a single pulse or double pulse mode This feature can be set ona channel by channel basis however it is recommended that you generally assign one operational mode for your city county or region Using one operation pulse mode assures that the user s will not be confused in the field Double Pulse Mode In this mode two distinct pulses are required to operate the device Using this mode will generally prevent almost all unwanted activations This mode is not able to be used in conjunction with trunk ed radio systems that don t have simplex or off trunk frequencies allocated Training support for double pulse activation is available at our website www click2enter net tutorial and enter the following password c2e10 36 and follow the instructions for the simulator Single Pulse Mode This allows for an on trunk activation of the C2E in most cases Simply key the transceiver once and release after the LED goes off and the C2E opens The potential for unwanted activation is increased slightly in this mode thus we encourage a tighter operational range setting to support single pulse activation All of the allocated trunk frequencies will need to be programmed into the Click2Enter in order to work in an on trunk mode PREFERRED METHOD OF OPERATION Frequency Assignment Selection of a frequency to operate th
26. of back up or support engines The C2E can hold open the gate in increments of 1 1 59 minutes 2 1 Hr to 15 Hrs 3 Stay Open permanently with a hard reset required The C2E can also once in latch back mode be set to either override or non override mode e Override Simply if latch back is initiated the system can be pulsed another time and the gate will close the system opens and closes on command e Non Override When set in this mode the C2E will hold the gate open for the predetermined amount of time and not allow an override request to close The activation LED blinks at a 50 duty cycle to indicate that it will not accept another pulse request pending completion of the countdown 9 Portable Radio Operation 4 Range of Operation Typically the portable setting for operation is approximately 20 Ft which places the mobile radio operation vehicle at about 80 Ft to 100 Ft Greater distances of operation can be achieved but consideration should be given to the potential of unwanted operation with greater distances Generally the 20 Ft portable and 80 Ft to 100 Ft mobile settings do well for all emergency access situations 5 Password Assignments The C2E supports two levels of password assignment to facilitate programming and access to stored data e The LEVEL 1 password might be allocated to the installing dealer e The LEVEL 2 password is typically used or allocated to the public safety agency o
27. r emergency access control systems will set the industry standard for many years to come The Click2Enter l combines scanner receiver technology with control technology to act as a radio controlled key to open access control devices gates or security control mechanisms allowing public safety agencies or any authorized users immediate access for dealing with emergencies as they occur All that is required to activate the Click2Enter l is that the operator be in proximity to the unit and use two short deliberate pulses of their radio transceiver to initiate an instant activation entry A final comment relating to SAFETY Never use the C2E device without proper safeties in place Safety devices and terminology are clearly defined under the UL 325 Guidelines We recommend that you have reviewed or are aware of the information covered under this very important document Should you want to DETOUR directly to the set up and programming section may we suggest beginning with Chapter 5 on Page 20 Features Scanner receiver radio Variable activation range via programming One or two radio transmission clicks for activation 50 channel capacity Mutual aid compatible Independent relay control for roll up doors Bright activation LED and power LED Time day agency memory recall CTCSS PL DPL private line PL programming capability Auto detect and load of private line codes Compatible with analog or digital radio
28. r hieten ia eke e A Sy te MMe ae 11 Installation of the Click2Enter l cccccceeeeeeeeeeeeeeeeeeeeeeeestneeeeeeees 14 4 CONFIGURATION 6 ccs ccccs cecseici ccenctseceventcereesatiecenscctiededecteseevsoteeceventac 17 O AEAEE EEE EEA EEEE E EA 17 Password ACCESS isis 18 TeS Mode e cet chile Mies neat tae es ated 19 5 PROGRAMMING aoran eas rita iia 20 Ove Woo a is tt 20 Programming the Click2Enter l cccceeeeeeeeeeeeeeeeeeeeeeeenneeeeeees 20 Programming with a Personal Digital Assistant c cceeeee 21 Logging Onto the Untsa r lasata bd 22 Programming Command Sussen naa a R 24 6 SPECIFICATIONS vecccccicccsccctccecstcececseecceeeseccevevsstecceesstccteevstecvecsseccess 29 7 CLICK2ENTER INC LIMITED WARRANTY cecccsseseeteneeseees 30 1 Introduction Overview Click2Enter C2E 1 does away with cumbersome keys access control codes and remote control actuators because every emergency response vehicle and responder already carries the key their mobile or portable radio transceiver Click2Enter l was developed to provide public safety personnel or any authorized user immediate access to electronically controlled gates common area doors roll up doors or any electronically controlled access control device Other authorized users can use Click2Enter l as long as they have programmed access into its frequency bank and have a radio transceiver Click2Enter l compared with othe
29. r surges floods fire natural disaster or extended to units which have been repaired or altered outside of the factory Click2Enter Inc reserves the right to make changes or improvements to our products without incurring any obligation to similarly alter products previously purchased The warranty represents DEPOT SERVICE and specifically excludes any costs associated with the troubleshooting removal shipment and reinstallation of Click2Enter unit s All repairs must be made at the factory or place designated in writing by Click2Enter Any product must be returned to Click2Enter with a Return Merchandise Authorization RMA number prominently marked on the outside of the package To obtain an RMA contact Click2Enter Inc by calling toll free 877 939 3800 or by writing Click2Enter Inc P O Box 1532 Sonoma California 95476 or via the world wide web at www click2enter net Freight will be paid by the party seeking warranty service and units shipped freight collect will be refused Click2Enter will pay freight on our return of repaired or replaced items in warranty using a shipping method similar to the one used to send the original unit to Click2Enter Inc THIS WARRANTY IS MADE EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTIES OF MERCHANTABLE QUALITY MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR THOSE ARISING BY LAW STATUTE USAGE OF TRADE OR COURSE OF DEALING AND
30. relay contacts to activate a multitude of devices Five year manganese dioxide lithium battery for memory backup Retrofit kits available for operation beyond temperature range specifications hot amp cold 2 Operation Overview How it Works Click2Enter l takes advantage of state of the art electronics presently being designed into scanner radio technology The modified scanner radio technology provides public safety agencies a quick safe reliable and stealthy means to activate gates or security control mechanisms Fire Departments Police Sheriff Departments Ambulance Rescue Companies and other public safety agencies are issued radio frequencies by the FCC for their restricted use only Possession of transmitting devices for non authorized personnel is tightly controlled and transmitting on these frequencies is against the law Federal amp State statutes The public s right to receive these emergency agency communications is not restricted making it legal to possess emergency response scanning devices The Click2Enter I uses technology that is inherent in most all radio broadcast equipment and adapts this technology to work as a control mechanism The security of the Click2Enter l is increased by requiring a verification of the FCC assigned carrier frequency and the agency assigned sub audible communication private line code So it takes two separate verifications to cause an activation of the unit An auto load fe
31. shown below appears Press for help C2E gt Figure 5a The Primary Programming Screen Command Prompt Press for help DUAL gt Figure 5b The Primary Programming Sereen Prompt For Independent Relay Control Function Independent Relay Control The DUAL feature or Change Dual Gate Mode function as seen in figure 6 is activated by typing B on the command prompt line Once initiated the command prompt changes from the C2E gt to DUAL gt as seen in figure 5b Once in this mode you can assign independent control of both the Gate A and Option B relays Note You will only be able to assign a pulse only 500mSec function to either of the two relays To return to the regular programming mode just type B again and the prompt will return to the familiar C2E gt 23 Programming Commands Enter the command to list the following maintenance commands C2E gt 2 A Adjust gain for a channel B Change Dual Gate Mode C Complete Program Listing D Set Date amp Time E Enter Channel Data G Toggle Gate Relay H List Activation History L List Channels O Toggle Option Relay P Change Passwords R Reset S Status Report T Toggle Test Mode X Exit Programming Mode Y Copy Test Channels Z Erase Channels Figure 6 Viewing the List of Programming Commands A This command allows the programmer to bypass all other programming steps and go directly
32. states it is unlawful to operate a scanner Please check the laws in your areas as they may change from time to time Click2Enter Inc assumes no liability for the operation of this scanner NOTE This is a required FCC standard operational disclaimer The Click2Enter product line is not intended to be used for scanning as intended by this disclaimer C2E 1ck2Enter Click2Enter Inc Designing and Manufacturing Access Control Technology For the 21 Century Protected By United States Patent Numbers 5 903 216 amp 5 955 947 European Patent Numbers Spain France United Kingdom Ireland amp Italy EP0956412 Germany D B P 69729321 1 Canadian Patent Number 2 275 189 FCC ID 07CC2E10 Industry Canada IC ID 6639A C2E10 Click2Enter Inc PO Box 1532 Sonoma CA 95476 www click2enter net Phone 707 939 3800 Toll Free 877 939 3800 Fax 707 996 3739 Email info click2enter net Click2Enter Inc 2 Contents FCC INFORMATION coccccconncccconnncnonannncnnnnnnnnrn enana nenas 1 1 INTRODUCTI N cvcocmcoociocosniniacintine ced cteedsaectereedectecesstenersesecteesesct 4 OIM Wicca A ana 4 EAU el aa dol Lord o Os A wat fa ld oy 5 2 OPERATION 50 6 OTATTE A EE dl A E E A E E anes ten 6 How it WOKS a a a e aaa a aare a aaa aain 6 Activation SEQUENCE iii A ee es 7 Initial System Setup Guidelines oooooooccccnncnincncooccccncccconannnnnnccnonnconnnnnos 8 3 INSTALLATION ooo inicias 11 MOUNTINGs see
33. to the Gain range setting step Thus making it easier to adjust the operating range once all other information has been entered This command switches the C2E l so that it can independently control the Gate A and Option B relays This typically used to control two separate devices or roll up doors with two separate frequency assignments This command will list the 50 event activation history date time and channel of activation the test channel register 0 49 channels and the activation channel register 0 49 channels This command sets the time and date of the on board clock chip The data must be entered exactly in the form mm dd yyyy hh mm For example 01 03 2004 18 43 Note Time is in 24 hour format 24 E This command allows the operator to enter data for a specific channel C2E gt E Channel 1 Frequency 462 5750 Mode C P D P PL Code 0 auto 69 3 Gain 100 Momentary gate relay Y N N default Gate mode S M H M default Gate open minutes 1 59 01 default Latch open amp hold N default Option control Y N N default Single pulse mode Y N N default C2E gt Figure 7a Entering Channel Data Momentary gate relay enabled N screen C2E gt E Channel 1 Frequency 462 5750 Mode C P D P PL Code 0 auto 69 3 Gain 100 Momentary gate relay Y N Y 50mSec PULSE Option Control Y N N Single pulse mode Y N N C2E gt
34. transmitters using private line sub audible transmissions Will operate with carrier only for use with digital radio systems Able to use talk around carriers car to car of trunk line radio systems Able to operate in an on trunk mode trunk ed radio systems single pulse mode only Able to receive radio transmissions to include 900 MHz bands Able to use aircraft AM band frequencies for airport access control operations Latch open and close features Enhanced user programmable latch open feature lets you specify gate open periods from one minute to unlimited Latch back and hold feature for extra safety Ability to handle high power mobile transmitters and lower power hand held portable transmitters Proprietary programming software built into each unit Field programmable using a laptop computer or PDA device with terminal emulation software and null modem adaptor Programmable via RS 232 interface User selected PIN for security of programmed frequencies Able to capture and exhibit activation data log via software Computer software programmable using standard terminal emulation software Windows Hyper Terminal Uses 12V to 24V DC Power Supplies Click2Enter power will be a regulated 12V DC 500mA Lightning surge current protected current surge limiting circuit Reflective logo for night identification Unit enclosed in a NEMA Type 4 box with security screws supplied Relay or dry contact ready Extra set of
35. ts the 50 most current entries stored in the activation history log L This command lists the contents of the channel memory NOTE Only the programmed channels will show all empty memory registers will not list O This command changes the state of the Option relay for testing purposes allowing field service personnel to check the wiring of the Option relay activates relay P This command allows the user to change passwords At level 1 only the level 1 password can be changed At level 2 the level 1 and level 2 passwords can be changed See Figure 8 below C2E gt P Password level 1 New Password 123456 Enter again 123456 C2E gt P Password level 2 New Password 234567 Enter again 234567 Typical error messages Invalid password or passwords don t match Installer password must start with a 1 Distributor password must start with a 2 C2E gt Figure 8 Changing Passwords 27 Level 1 must begin with the number 1 and level 2 must begin with the number 2 as shown in Figure 8 above See section titled Access Control The previous example shows the original factory override passwords R The reset command resets the Click2Enter l to a normal operating status as follows e Test Mode is cancelled e The gate is closed e The option control is deactivated S This command lists the current state of the Click2Enter I T This command toggles the test mode on or off See section titled Test Mode
Download Pdf Manuals
Related Search
Related Contents
Steam Bottle Sterilizer Stérilisateur Biberon Electrique support PDF Descargar - Interroll NETWORK CAMERA SERIES Bomba neumática de aceite y diesel 1:1 Copyright © All rights reserved.
Failed to retrieve file