Home
        User`s Manual CFM Thermo Anemometer Model
         Contents
1.      CFM  ft3 min    Air Velocity  ft min  x Area  ft    CMM  m  min    Air Velocity  m sec  x Area  m    x 60       NOTE  Measurements made in inches  must be converted to feet or meters before using the above formulae        Unit of Measure Conversion Table          m s ft min knots km h MPH    1 ft min   cose f 1   ooer   0 01829 0 01138  wa   osu   mar  1   tose   a  1 km h 0 54 0 6222    1 MPH 0 4464 87 89 0 8679 1 6071 1                         8 407114 V1 7 04 03    
2.   Battery Replacement       When the    LBT    icon appears on the LCD  the 9V battery must be replaced     1      Remove the rubber holster that surrounds the entire meter  2  Slide off the rear battery compartment   3    4  Affix the battery compartment cover and the meter holster    Replace the 9V battery    RS 232 PC Interface       The 407114 is equipped with a 3 5mm phone jack  meter top  for connection to a  PC for data acquisition purposes  To obtain PC interface cabling and Windows     data acquisition software  contact Extech Instruments  Instructions for use are  provided with the data acquisition software hardware kits     6 407114 V1 7 04 03    Warranty       EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and  workmanship for one year from date of shipment  a six month limited warranty applies on sensors and  cables   If it should become necessary to return the instrument for service during or beyond the warranty  period  contact the Customer Service Department at  781  890 7440 ext  210 for authorization or visit our  website at www extech com  click on    Contact Extech    and go to    Service Department    to request an RA  number   A Return Authorization  RA  number must be issued before any product is returned to Extech  The  sender is responsible for shipping charges  freight  insurance and proper packaging to prevent damage in  transit  This warranty does not apply to defects resulting from action of the user such as
3.   feet per minute  80     4921 ft min   2    20 ft min   mph  miles per hour  0 9     55 9 mph 0 1 mph    2    0 2 mph     knots  nautical miles per 0 8 to 48 6 knots 0 1 knots      2    0 2 knots   hour      CMM  cubic meters per   0 999 900 m  min 0 001 to 0 to 9 999m   minute  100  CFM  cubic feet per 0 999 900 ft  min 0 001 to 0 to 9 999ft   minute  100    L  82 122   F  0 50  C   0 1 CFIC 1 5   F  0 8   C        2 407114 V1 7 04 03    Meter Description       1  LCD Display  2  Keypad  3  Sensor    4  Sensor Input    5  RS 232 PC Interface jack    oma ve  Anemometer    6  Protective rubber holster       7  Battery compartment  rear     Note  To access the rear battery compartment first remove the meter s rubber  protective holster     3 407114 V1 7 04 03    Operation       Air Velocity Measurements    1   2   3     Connect the sensor to the sensor input jack on top of the meter   Turn on the meter using the Power button     Select the VELOCITY function using the VEL FLOW button  The LCD will  display    VEL    when the velocity mode is selected     Select the desired temperature units using the C F select button  The LCD  will reflect the current unit selection     Select the desired air velocity units using the UNIT button  The LCD will  reflect the current unit selection   For maximum accuracy  the airflow must enter Side view of Vane  the vane on the side without the yellow dot yellow   see diagram   dot   DO pam airflow    View the air velocity and temperature reading
4.  air flow units  CMM  cubic meters per minute  or CFM   cubic feet per minute  using the UNIT button  The LCD will reflect the  selection     Press the AREA button to begin entering the area in m   or ft     Use the  amp   button to increment the flashing digit  use the Y button to decrement the  flashing digit  use the    button to select the next digit  and use the  RECORD RECALL    button to set the decimal point  Press the  ENTER RESET button when the area has been entered  The bottom display   normally used for the temperature display  will indicate the area entered in   ft  or m    The main LCD displays the air flow in CFM  cubic feet per minute   or CMM  cubic meters per minute   Refer to the Area Equations in the back of  this manual     For air flow measurements  three modes apply  The normal  default mode   where the actual flow is indicated  and the two modes described below  Press  the FLOW MODE button to select one of the two modes listed below     2 3V MAX MODE  LCD displays 2 3 the measured value     AVG MODE  Up to 20 readings can be taken separately and averaged   Select the AVG mode via the FLOW MODE button and then press the  AVG START button to take a reading  Up to 20 readings can be taken  and averaged  The lower LCD display provides a 1 to 20 counter and  each time a reading is taken the counter is incremented  The main LCD  displays the averaged air flow     Note that the temperature function is not active in the AIR FLOW mode     5 407114 V1 7 04 03  
5.  misuse  improper  wiring  operation outside of specification  improper maintenance or repair  or unauthorized modification   Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and  will not be liable for any direct  indirect  incidental or consequential damages  Extech s total liability is limited  to repair or replacement of the product  The warranty set forth above is inclusive and no other warranty   whether written or oral  is expressed or implied     Calibration and Repair Services       Extech offers repair and calibration services for the products we sell  Extech also  provides NIST certification for most products  Call the Customer Service  Department for information on calibration services available for this product   Extech recommends that annual calibrations be performed to verify meter  performance and accuracy        T  Support Hotline  781  890 7440    Tech support  Ext  200  Email  support extech com  Repair Returns  Ext  210  Email  repair extech com  Website  www extech com                Copyright    2003 Extech Instruments Corporation    All rights reserved including the right of reproduction in whole or in part in any form     7 407114 V1 7 04 03    Useful Equations and Conversions       Area equation for rectangular or square ducts    Width  W  Area  A    Width  W  x Height  H     Area equation for circular ducts    Cubic equations    Area  A       x r   Where      3 14 and r     radius x    radius  
6. User s Manual    EXT    INSTRUMENTS       CFM Thermo Anemometer  Air Velocity  Air Flow  and Temperature    Model 407114       i  FLOW MODE  I    AVG START ENTER RESET AREA  I i I    CFM hore 407114    Introduction       Congratulations on your purchase of the Extech CFM Thermo Anemometer  This  meter measures Air Velocity  Air Flow and Temperature  An RS 232 PC  interface provides data acquisition functionality  Proper use of this meter will  provide years of reliable service     Specifications    Custom LSI microprocessor circuit  Display Dual function 0 5   13 mm  4 digit  9999 count  LCD    Measurement units Air Velocity  m s  km h  ft min  knots  mph     Air Flow  CMM  m  min  and CFM  ft  min  Temp    C  and   F    Data hold Freezes displayed reading  Sampling rate 1 second approx     Sensors Air velocity flow sensor  Conventional angled vane  arms with low friction ball bearing   Temp  sensor  Precision thermistor    MAX MIN Memory Record and view Maximum and Minimum readings  Automatic Power off Auto shut off after 15 minutes to preserve battery life    Data Output RS 232 PC serial interface with 16 bit data stream  output    Operating Temperature  32  F to 122  F  0  C to 50  C   ine        Dimensions Main instrument  7 1 x 2 8 x1 3   180 x 72 x 32mm   Sensor Head  2 8     72mm  diameter   Air Velocity Accuracy  rdg    m s  meters per sec  0 4 to 25 00 m s 0 01 m s    2    0 2 m s     km h  kilometers per 1 4 to 90 0 km h 0 14 km h    2    0 2 km hr   hour     ft min
7. s  on the LCD Display  The large main LCD  display shows the Air Velocity reading  The  lower LCD sub display shows the temperature  reading      lt        Data Hold Feature    1     3     While taking measurements  press the HOLD button to freeze the LCD  reading for later viewing     The    DH    indicator will appear on the LCD when the display is in Data Hold  mode     Press HOLD again to return to normal operation     Maximum and Minimum Recording    The 407114 allows the user to record and view the highest  MAX  and lowest   MIN  readings   Press the RECORD RECALL button once  The    REC    indicator will appear  on the display and the meter will begin keeping track of the MAX and MIN  values   To view the MAX reading  press RECORD RECALL again  The    MAX     indicator along with the maximum reading will appear on the LCD display   Press RECORD RECALL again to view the minimum value  the    MIN     indicator along with the minimum reading will appear on the LCD display   To return to normal operation  press and hold the    RECORD RECALL       button for approx  3 seconds  The display indicators REC  MAX  and MIN  will disappear     4 407114 V1 7 04 03    Air Flow Measurements  CMM   CFM     1   2   3     Connect the sensor to the sensor input jack on top of the meter   Turn on the meter using the Power button     Select the FLOW mode using the FLOW VELOCITY button  The LCD will  display    FLOW    when the flow function has been properly selected     Select the desired
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
まず、このセットアップガイドを お読みください。  Jumbo iPawn Slangen & Ladders  TerraTec Producer KOMPLEXER VST Manuel français Version 1.00  Frigidaire GLGQ942CS Gas Commercial Dryer    コンドームパッケージデザイン プロジェクト 参加作品  Samsung NP540U3C User Manual (Windows 8)  User Manual-EN-SG30KTL_SG30KTL-M-Ver12  I-Tech Company GS4600 User's Manual  USER`S MANUAL - California Analytical Instruments, Inc.    Copyright © All rights reserved. 