1.      LCD keypad with mechanical keys    INT KLCDL     LCD keypad with mechanical keys    INT KLCDS     LCD keypad with mechanical keys    INT KLFR     LCD keypad with mechanical keys and built in proximity card reader     The keypads are available in a variety of color options for the enclosure  display and key  backlight  The color variant is indicated by the additional designation in the keypad name   e g  INT KLCD GR     green display and key backlight  INT KLCD BL     blue display and key  backlight      5 1 Keypads description  The INT TSG  INT TSI and INT KSG keypads are described in separate manuals   which are delivered with these keypads     5 1 1 LCD display    The display facilitates communication between the user and the alarm system  clearly  indicating the system status  The functions available to the user are presented on the display   The display backlight can be used  if needed     In standby mode  the display shows       in the upper line     the date and time in the format defined by the installer         in the lower line     the keypad name or state  status  of selected partitions  to be defined  by the installer      The installer can configure the keypad so that when you press the 9 key for approx  3  seconds  the display will enter the partition state presentation mode  The status of  partitions operated by the keypad  including those from which alarm is signaled on the  keypad  is presented by means of symbols  The display will return to the standby m
2.      a group of outputs will be displayed     using the V and A keys  find the group which  includes an output  and then press the   key to display the list of outputs         the list of controllable outputs will be displayed at once     3  Using the V and A keys  find in the list the output whose status you want to change to  control the device connected to the output  The output status is presented by means of  symbols       output inactive  disabled        output active  enabled      The output status can be presented according to the zone status  The displayed  symbols should then be interpreted as follows         zone not violated  the device controlled by output is inactive    iii   zone violated  the device controlled by output is active      SATEL INTEGRA 35       The way of presenting the status of roller shutter outputs differs from how the status of  other outputs is presented  see  section CONTROLLING THE ROLLER SHUTTER OUTPUTS      5 14 1 Controlling the MONO switch type of output    When the output is inactive       pressing the b key will activate the output for the time programmed by the installer       pressing the   key will allow you to program the time for which the output will be  activated upon the next pressing of the   key   When the output is active  pressing any digit key will turn the output off     5 14 2 Controlling the BiswitcH type of output    Pressing the   or    key will change over the output status  Additionally  when the output is  active
3.    4 short and 1 long beeps     confirmation that the function has been executed   3 pairs of short beeps     the user should change his her code   1 long beep     refusal to arm  there are violated zones in the partition or there is a trouble    2 long beeps     unknown code card   3 long beeps     unavailable function     Events signaled by sounds    Only installer selected events are signaled     Alarms are signaled for the time programmed by the installer     5 short beeps     zone violation  CHIME      Long beep every 3 seconds  followed by a series of short beeps for 10 seconds  and 1 long beep     countdown of exit delay  if the time is shorter than 10 seconds  only  the final sequence of short beeps will be generated      A sequence of 7 beeps of diminishing duration  repeated every few seconds      countdown of auto arming delay     2 short beeps every second     countdown of entry delay   Continuous beep     alarm    Long beeps every 2 seconds     alarm memory    Long beep every second     fire alarm    Short beeps every 2 seconds     fire alarm memory   Very short beeps     door open too long     38 User Manual SATEL       6 2 Functions available from the partition keypad    6 2 1  Code     Depending on the user type and authority level  keypad settings and the alarm system status   entering the code and confirming with the   key will result in        unlocking the door  activating the relay         disarming the partition        clearing alarm        changing over
4.   Brief description of operating the system from keypad                    eee e eee e sees eeeeeeeeeeeeeeeeeeeee 46    4 User Manual SATEL       1  General    Thank you for choosing the product offered by the SATEL Company  Wishing you full  satisfaction with the choice you made  we are always ready to provide you with professional  assistance and information on our products     The SATEL Company is manufacturer of a broad range of devices dedicated for use in  security alarm systems  Further information is available on our website www satel eu or at  the points of sale offering our products     2  Technical reliability of the alarm system    The alarm system is built of technical devices  the performance of which has crucial effect on  the effectiveness of the facility protection  Components of the alarm system may be exposed  to various external factors  such as weather conditions  e g  outdoor sirens and  during  a storm  also other devices  as a result of atmospheric discharge which may cause harm to  electrical and telephone installations  or mechanical damage  Only a routine check of the  system operation makes it possible to maintain a high level of burglary protection    The control panel is provided with a number of safeguards and automatic diagnostic features  to test the system performance  Detection of irregularities is signaled by the T   LED on the  keypad  You should immediately respond to such a signal  and  if necessary  consult  the installer     It is nece
5.   Edit user     allows to edit the existing users  see  section EDIT USER p  27    Remove user     allows to remove the existing users  see  section REMOVE USER p  28      The administrator defines whether the installer is to have access to the USERS  submenu  SERV  CAN EDIT option in the CHANGE OPTIONS submenu     Masters     the submenu provides the following functions available to the installer   New master     allows to create a new administrator   Edit master     allows to edit the existing administrators   Remove master     allows to remove the existing administrators    Zone bypasses     the following functions are available in the submenu    Inhibit     allows to temporarily bypass the zones  see  section ZONE BYPASSING  INHIBIT   p  30     Isolate     allows to permanently bypass the zones  see  section PERMANENT BYPASSING   ISOLATE  p  30      Set time     allows to program the control panel clock  The data are entered in the following  format     time     hour minute second   date     day month year     System state     allows to view the troubles and  if the GRADE 2 global option has been  enabled by the installer  also the alarms and bypassed zones  as well as to check the  partition status     Events     the submenu contains functions which allow to view the events saved to the control  panel memory  see  section EVENT LOG REVIEWING p  31      The content of received SMS messages is also saved to the events log of the  INTEGRA 128 WRL control panel     Reset zon
6.   pressing any digit key will turn the output off     5 14 3 Controlling the REMOTE SWITCH type of outputs    Depending on how the output has been programmed  pressing the   or  gt  key will activate  the output for the time programmed by the installer or change over the output status   Additionally  when the output is active  pressing any digit key will turn the output off     5 14 4 Controlling the roller shutter outputs    The SHUTTER UP and SHUTTER DOWN type of outputs are always programmed as consecutive  and in pairs  Displayed on the list of outputs is only the name of output programmed as  SHUTTER UP  The status of outputs is presented by means of symbols        outputs inactive  off     tT   SHUTTER UP output active  on          SHUTTER DOWN output active  on     Pressing the   or b key will display the cursor in the form of a horizontal line under the  output status symbol  Pressing the A key will turn on the SHUTTER UP type output  if both  outputs are inactive  or turn off the SHUTTER DOWN type output  if it is active   Pressing the V  key will turn on the SHUTTER DOWN type output  if both outputs are inactive  or turn off the  SHUTTER UP type output  if it is active   Irrespective of which output is currently active   pressing any digit key will turn the output off  When the control is finished  press the   or  lt   key to return to the list of outputs which can be controlled  the cursor under the symbol will  disappear      6  Using the partition keypad    The m
7.   remove 433 MHz keyfob   assign function to keyfob button 1   assign function to keyfob button 2   assign function to keyfob button 3   assign function to keyfob button 4   assign function to combination of keyfob buttons 1  amp  2  assign function to combination of keyfob buttons 1  amp  3  set event generating rules   add keyfob supported by ABAX system  remove keyfob supported by ABAX system  assign function to keyfob button 1   assign function to keyfob button 2   assign function to keyfob button 3   assign function to keyfob button 4   assign function to keyfob button 5   assign function to combination of keyfob buttons 1  amp  5  set event generating rules   set confirmation rules   program user name    Edit user   select user    list of parameters identical as in case of a new user   Remove user remove user    edit existing user    New master add new master  Code set code  Rights assign rights    Keypads etc   New prox  card  Rem  prox  card  New DALLAS  Remove DALLAS  New RX keyfob  Rem  RX keyfob  Button 1   Button 2   Button 3    assign modules available to the master  add proximity card   remove proximity card   add DALLAS iButton   remove DALLAS iButton   add 433 MHz keyfob   remove 433 MHz keyfob   assign function to keyfob button 1  assign function to keyfob button 2  assign function to keyfob button 3    SATEL    INTEGRA 13       Button 4  Button 1 and 2  Button 1 and 3  Events  RX     New ABAX keyfob  Rem ABAX keyfob    Button 1  Button 2  Button 3  Button 4 
8.   see also  description of the HS LEDs  p  8   Pressing the key O  1 or 2 three times in the graphic mode  within 3 seconds will have the following effect   000   the   symbol will be displayed at all available items   111   the El symbol will be displayed at all available items   222   reversal of the selection made  the  amp  symbol will be displayed at all items where  the   symbol was displayed  and the   symbol where the   symbol was displayed   On pressing the V or A key  the keypad will return to the text mode     Fig  3  Example of how information is presented in the graphic programming mode  The blank  fields are not available for editing        Entering decimal and hexadecimal values    Digits are entered by pressing the suitable keys  Characters from A to F are available under  the keys with numbers 2 and 3  Keep pressing the keys until the required character appears     Entering names    Press the particular keys until the required character appears  The characters  available in the keypad are shown in Table 3  Hold down the key to display the digit  assigned to the key          Characters available after next keystroke                                                      1   2      el  e rls wfsje     lleft 1   2 a  bic  2   3 dle  f    3   4 g h  i   4   5 jiki LS   6 min jo 6   T7 piqlriis   8 t  ulv diii   9 w x jy  z   0                     Table 3  Characters available when entering names  The lower case letters are available  under the same keys  to change 
9.  10 3 Audio alarm verification    1  Get access to the phone call answering function  steps 1 2 in section ANSWERING PHONE  CALLS     2  Within up to 15 seconds  press in turn the 3 and   keys on the telephone keypad  4 short  beeps and 1 long beep will confirm that you have got access to the function of audible  alarm verification  The DTMF commands you can use after starting the listen in   talk  session are described in the INT AV module manual     11  SMS control easter LIS    The INTEGRA 128 WRL control panel can be operated by means of the SMS messages  containing suitable control commands  The content of commands and the additional rules of  how to use them  using the lower case and upper case letters  adding the telephone code to  the content of sent SMS message  etc   are to be defined by the installer  If appropriate  control commands are programmed by the installer  the SMS messages can be used to        violate selected zones        temporary bypass selected zones        unbypass selected zones        arm selected partitions in selected mode        disarm selected partitions        clear alarm in selected partitions        activate selected MONO SWITCH type outputs        activate selected BI SWITCH type outputs        deactivate selected Bl SWITCH type outputs        toggle selected BI SWITCH type outputs        check status of selected partitions     Remote audio alarm verification is possible when the INT AV module is connected to  the control panel        44 U
10.  Button 5  Button 1 and 5    Events  ABAX   Confirm   ABAX     Name  Edit master   select master     assign function to keyfob button 4   assign function to combination of keyfob buttons 1  amp  2  assign function to combination of keyfob buttons 1  amp  3  set event generating rules   add keyfob supported by ABAX system   remove keyfob supported by ABAX system   assign function to keyfob button 1   assign function to keyfob button 2   assign function to keyfob button 3   assign function to keyfob button 4   assign function to keyfob button 5   assign function to combination of keyfob buttons 1  amp  5  set event generating rules   set confirmation rules   set master name   edit existing master     list of parameters identical as in case of a new master     Remove master  Zone bypasses  Inhibit  Isolate  Set time  System state  Events  Selected  Select events  Select part   View  View Grade2  All  Grade2  Reset zones  Clr latch outs  Fin f door open  Change options  Keypad chime  Outputs chime  Timers  Part  timers  No exp tamp al     Perm serv accs     Perm DloadX acc          DloadX IP  GuardX IP  Erase s message    Tests    Partitions  Zones    SIUI VAVOLET GE    remove master    temporary zone bypass   permanent zone bypass   set control panel clock   check troubles   check system state    select type of events to be viewed   select partitions from which events are to be viewed  view selected events   view events required for Grade 2   view all events   view events requir
11.  alarm     press the  INT S     INT SK         INT SCR  key for approx  3  seconds    medical  auxiliary  alarm     press the 0 key for approx  3 seconds    panic alarm     press the  INT S     INT SK          INT SCR  key for approx  3  seconds  The installer defines whether the triggered alarm will be loud  setting off the loud  alarm signaling  or silent  without loud signaling            6 2 5 Silencing the alarm sound at the keypad    If the keypad is signaling alarm  pressing any digit key will silence the signaling for approx  40  seconds     SATEL INTEGRA 39       6 2 6 Code changing    The installer can permit the change of own code by means of the partition keypad    1  Press the 1 key for 3 seconds    2  When the La  and    gt  LEDs start blinking alternately  enter the old code and confirm it  with the   key     3  When the La and T   LEDs start blinking alternately  enter the new code and confirm it  with the   key     7  Using the entry keypad    The INT SCR multifunction keypad can work in the entry keypad mode  INT ENT   The main  task of the zone keypad is activation of the delay for the 3  INTERIOR DELAYED type zones  The  time period during which these zones will act as delayed ones is programmable for the  keypad  If more than one zone keypads are assigned to the partition  a different delay  unblocking time can be programmed for each of them  After expiry of the programmed time   the interior delayed zones will again operate as instant ones     7 1 LED in
12.  arming   If the arming procedure could not be started  the displayed message can allow of the forced  arming  1 Arm   On pressing the 1 key  the system will be armed despite a violated zone ora  trouble     5 4 6 Failure of arming procedure    If the installer has enabled the GRADE 2 option  the arming procedure may end in failure  The  system will not be armed  if at the end of the exit delay countdown       there is a violated zone in partition which was not violated when the arming procedure  was started       there is a trouble which did not exist when the arming procedure was started     5 4 7 Shortening the exit delay time    If such an option is permitted by the installer  the partition exit delay time may be shortened  upon pressing in turn the 9 and H keys     24 User Manual SATEL       5 5 Disarming and alarm clearing    Enter the code and confirm with the   key  see  section  Cope       ARMING   DISARMING MENU  p  10   If only selected partitions are to be disarmed  DISARM SELECTED function   the  partitions should be selected in the same way as when arming the selected partitions     5 5 1 Alarm clearing without disarming    1  Enter the code and confirm with the   key   2  Using the VW key  scroll through the menu until the CLEAR ALARM function is found   3  Press the   key     5 6 Two code arming   disarming    If the partition is to be armed   disarmed with 2 codes  the user entering the first code must   1  Enter the code and confirm with the  K key     2  Sc
13.  case of damage or failure of the  detector connected to the zone  which results in malfunctioning of the alarm system  e g   triggering false alarms      Zone bypassing reduces the level of protection  Prior to arming  make sure that there  are no accidentally bypassed zones in the partition  which might allow an intruder to  get access to the protected area despite arming     If a zone is bypassed  call in the installer  service technician  immediately to repair the  defect     For security considerations  the installer may reduce the number of zones that the user  will be allowed to bypass     5 10 1 Zone inhibiting    The zones can be inhibited by the users having the ZONES BYPASSING right  The inhibited  zone will be bypassed until the partition to which the zone belongs is disarmed  or until the  zone is unbypassed by the user     1  Enter the code and confirm with the   key    2  Press in turn the 4 and 1 keys  The list of zones will be displayed  There is an additional  symbol in the upper right hand corner of the display to inform you about the given zone  status          the zone is not bypassed   EJ     the zone is inhibited   El     the zone is isolated    3  Using the V and A keys  find in the list the zone which is to be inhibited    4  Press any digit key until the ii  symbol appears in the upper right hand corner of the  display    5  Repeat the steps 3 and 4 for the next zones which are to be inhibited    6  Press the   key  A message will inform you that the
14.  function is only displayed  when a keyfob has already been assigned to the user    2  When the keyfob number and a prompt whether the keyfob is to be removed are  displayed  press the 1 key  You will be brought back to the list of functions for defining the  user parameters     3  Press the   key   4  When a prompt appears  asking you if the changes are to be saved  press the 1 key     Removal of a keyfob will not erase its settings  dependences between the buttons  and zones  confirmation rules  etc    When added to the user  the new keyfob will have  the same settings as the deleted one     The installer can remove all keyfobs  including their settings  by means of the functions  available in the service mode  P STRUCTURE    HARDWARE    EXPANDERS    REM RX KEY  FOBS   REM ABAX KEYFOB      30 User Manual SATEL       The administrators  keyfobs are removed in the same way     5 9 Master users  administrators     The master users  administrators  can be added  edited and removed by the installer  There  can be 1 administrator in each object  The administrator has access to all partitions in the  object and also specifies how the system can be accessed by using the service code  Most of  the parameters which are defined for the ordinary user can be defined for the administrator   see  section USERS p  24      5 10 Zone bypassing    You can bypass   unbypass zones in the disarmed partitions  Violating a bypassed zone will  not trigger any alarm  Bypassing the zones is useful in
15.  means having made the round  additionally  it can result in the  partition being temporarily bypassed for the duration of guard round   The installer defines  the modules which are used to confirm making the round and determines the time interval  between successive rounds  If such a user is granted access to the partition  he she will  have the same possibilities as the NORMAL type user     Scheduled     the user has access to the system as per the time schedule for a specified  period of time  It is necessary to select the schedule  the schedule is programmed by the  installer  and define the user validity period     5 8 2 Adding new user    1  Enter the code and confirm with the   key   2  Press in turn the 2 and 1 keys  The list of functions to define the user parameters will be  displayed     If the service code has been entered  before the list of functions is displayed  it is  necessary to specify the object in which the new user is to be created  the service  code enables access to all objects      3  Using the appropriate functions  define the user s parameters     At least one identifier  i e  code  proximity card  DALLAS iButton or keyfob  must be  assigned to the user     The new user may not be granted a higher authority level than the person who is  adding that user to the system    4  Press the   key    5  When a prompt appears  asking you if the changes are to be saved  press the 1 key     6  A message will inform you that a new user has been created  Press t
16.  message  Having listened to the message can be confirmed from the  keypad of DTMF dialing telephone  The installer defines whether any 4 digit sequence is  sufficient to confirm receipt of a voice message  or it must be a specific code  After entering  of the code  the control panel will give the following information by means of sound signals     1 short beep repeated every 3 seconds     the message has been confirmed  wait for  playback of the next voice message    4 short and 1 long beeps     the message has been confirmed  there are no more voice  messages     42 User Manual SATEL       2 long beeps     an invalid code has been entered  the message has not been confirmed      If the control panel is sending messages about several events and confirmation of the  voice messages is required  each message should be confirmed  The first message  must be confirmed before the second message can be played back  an so on     The installer can configure the control panel so that acknowledgement of receiving the  message by the user will         clear messaging other users       allow to get access to the INT VG module voice menu     10  Call answering and telephone control    The information below does not apply to the control panels to which the INT VG  module is connected     The call answering and telephone control functions are available to the users who have the  telephone code  These functions require that the DTMF dialing phone be used  The call  answering function allows t
17.  other zones  see also description of the HS LEDs  p  8   By factory default  the  zone status is shown using the following symbols  which can be changed by the  installer       zone bypass      trouble  long violation       trouble  no violation       tamper alarm    alarm      zone tamper      zone violation      tamper alarm memory      alarm memory      zone OK    Supply voltages     available to the installer  Enables checking of the supply voltage for  individual expansion modules    Temperatures     allows to check the temperatures measured by ATD 100 wireless  detectors    Radio devices     allows to check the radio signal level for ABAX system wireless devices  supported by the control panel    Zone Test     the submenu contains functions which allow to test the detectors connected  to the zones  see  section ZONE TESTING p  33     Battery test     available to the installer  Upon starting the function  the control panel will  generate events to inform about the status of batteries of the control panel and  hardwired expansion modules with power supply  Additionally  the status of 60  TECH    BATTERY LOW type zones will be analyzed    Manual transmission test     generates an event  which starts the procedure of event  transmission to the monitoring station  a code sent with the system identifier     Monitoring station test  1A  1B  2A  2B      allows to send a test transmission to the  monitoring station  separate functions for each of the telephone numbers   When  
18.  the programmed time  using the  FINISH TEST function  P TESTS    ZONE TEST    FINISH TEST   Up to 6 seconds can elapse  between starting the function to the actual end of the test  during this the FINISH TEST  function will be still available      12  Depending on the type of tested detector         magnetic contact     open and close the door or window protected by means of the  magnetic contact       motion detectors     pass in front of the detector       other detectors     follow the manufacturer s directions for the detector testing   13 Look through the test results  To do so  enter again the ZONES TEST submenu  see  steps  1 5  and start the VIEW RESULTS function  You can scroll through the list of results  using  the A and V keys  Press the b or 4 key to switch over the display to the graphic mode   in which information is provided by means of symbols     zone was not violated   iii   zone was violated     Pressing the    or 4 key in the graphic mode will display information on another set of  zones  see also description of the H7 LEDs  p  8      The test results can be deleted by means of the CLEAR RESULTS function     TESTS     ZONES TEST    CLEAR RESULTS         5 14 Outputs control    If permitted by the installer  the control function can be started without user  authorization  upon pressing in turn the 8 and   keys    1  Enter the code and confirm with the    key    2  Press the 8 key  Depending on how the control panel has been configured by the installer    
19.  the status of 25  BI SWITCH type outputs        turning on the 24  MONO SWITCH type outputs        guard round confirmation        enabling temporary partition blocking     Most of the abovementioned functions are available after enabling the Lock  LOCK  FEATURE  option for the partition keypad  Whether the functions are available may also  depend on the other keypad options  e g  if the lock operates in the ON IF PARTITION  ARMED  ON IF PART ARMED  mode  most of the functions will be unavailable      6 2 2  Code      Depending on the user type and authority level  keypad settings and the alarm system status   entering the code and confirming with the   key will result in        initiating the partition arming procedure        disarming the partition        clearing alarm        changing over the status of 25  BI SWITCH type outputs        turning on the 24  MONO SWITCH type outputs        guard round confirmation        enabling temporary partition blocking        unblocking cash machine access     6 2 3 Quick arming    The installer can permit arming without the user authorization     1  Select the arming mode  press one of the keys  O     full arming  1     full arming    bypasses  2     arming without interior  3     arming without interior and without entry delay      2  Press the   key  The arming procedure will begin     6 2 4 Triggering the alarm from keypad    The installer can permit triggering alarms from the keypad  To trigger an alarm  do the   following    fire
20.  unbypassed upon  pressing the   key     5 11 Viewing the event log    The events viewing function  when started by the administrator or the ordinary user   provides no information about         panic alarms       alarms triggered using the DURESS type code     5 11 1 Viewing all events    1  Enter the code and confirm with the  K key    2  Press in turn the 5 and 2 keys  The last event which occurred in the system will be  displayed    3  Using the A key  scroll through the list of previous events     5 11 2 Viewing the events required for Grade 2   If the GRADE 2 option is enabled in the system  the function allowing the installer and   administrators to view events required by EN 50131 for Grade 2 is available    1  Enter the code and confirm with the   key    2  Press the 5 key  Functions available in the EVENTS submenu will be displayed    3  Using the W key  scroll the menu until the GRADE2 function is found    4  Press the   key  The last Grade 2 required event which occurred in the system will be  displayed    5  Using the A key  scroll through the list of previous events     32 User Manual SATEL       5 11 3 Viewing the selected events    1  Enter the code and confirm with the   key   2  Press in turn the 5 and 1 keys     3  When the SELECT EVENTS function is displayed  press the   key  The list of event types  will be displayed     4  Select which event types are to be displayed  see  section SELECTION FROM THE MULTIPLE   CHOICE LIST p  15      5  Press the   key  T
21.  zones are inhibited     Having started the INHIBIT function  step 2   you can press the    or 4 key to switch  over the keypad to the graphic programming mode  see  section SELECTION FROM THE  MULTIPLE CHOICE LIST p  15      5 10 2 Zone isolating    The zones can be isolated by the users having the ZONES BYPASSING and ZONE ISOLATION  rights  The isolated zone will remain bypassed until unbypassed by the user     SATEL INTEGRA 31       1  Enter the code and confirm with the  K key     2  Press in turn the 4 and 2 keys  The list of zones will be displayed  There is an additional  symbol in the upper right hand corner of the display to inform you about the given zone  status          the zone is not bypassed   id     the zone is inhibited   EE     the zone is isolated   3  Using the VW and A keys  find in the list the zone which is to be isolated     display   5  Repeat the steps 3 and 4 for the next zones which are to be isolated   6  Press the   key  A message will inform you that the zones are isolated     Having started the ISOLATE function  step 2   you can press the    or 4 key to switch  over the keypad to the graphic programming mode  see  section SELECTION FROM THE  MULTIPLE CHOICE LIST p  15      5 10 3 Unbypassing    The zones can be unbypassed by the users having the ZONES BYPASSING right  Proceed in  the same way as when inhibiting or isolating the zones  steps 1 3   but the   symbol must be  shown in the upper right hand corner of the display  if the zone is to be
22. GUARDX  program is installed  The address must be set if the control panel is to initiate  communication with the GUARDX program through Ethernet  using the TCP IP protocols   see  description of the ETHM 1     GUARDX function  available in the DOWNLOADING  submenu   It can be entered as a name or IP address     Erase service message     allows the user to delete the service message   Tests     the following functions are available in the submenu     Partitions     allows to check the status of partitions accessible to the user and operated  from the keypad  The partition status is presented by means of a symbol  The numbers  placed on the glass allow you to identify the partition numbers  By factory default  the  partition status is shown using the following symbols  which can be changed by the    installer     b   temporary blocked        entry delay    E   exit delay  less than 10 seconds    e   exit delay  more than 10 seconds    P   fire alarm     20    User Manual SATEL         alarm    fire alarm memory      alarm memory      armed      disarmed  not ready to be armed  violated zones       disarmed  ready to be armed    Zones     allows to check the status of zones in the partitions accessible to the user and  operated from the keypad  The zone status is presented by means of a symbol  The  numbers placed on the glass allow you to identify the zone numbers  On starting the  function  the status of zones 1 32 is displayed  Use the    and 4 keys to display the  status of
23. Saged     USER  MANUAL    INTEGRA       Alarm Control Panels    SATEL sp  Z 0 0    ul  Schuberta 79  80 172 Gda  sk  POLAND   tel    48 58 320 94 00    info satel pl  www satel eu       integra _u_en 12 13    WARNING    Before you start using the control panel  please read carefully this manual in order to avoid  mistakes that can lead to malfunction or even damage to the equipment     Changes  modifications or repairs not authorized by the manufacturer shall void your rights  under the warranty     The INTEGRA control panels should only be connected to the analog subscriber lines  In  case of changing the analog line to the digital one  it is necessary to contact the alarm  system installer     Pay special attention if the telephone line used by the control panel is frequently busy and or  failures are reported  concerning the line and or monitoring  Report such situations to the  alarm system installer immediately    To ensure adequate protection  the alarm security system must be in good working order   therefore SATEL recommends that it be regularly tested  The control panel is equipped with  a number of self diagnostic functions which  when properly configured by the installer  ensure  control over correct functioning of the system    The alarm security system cannot prevent burglary  assault or fire from happening  but it  guarantees that in case of emergency measures will be taken to reduce the possible damage   the alarm will be signaled optically and acoustically  ap
24. ain task of the partition keypad is to arm disarm one partition  Additionally  it offers a  number of other functions  including e g  the access control  Supervision of a single door      SATEL offers the following partition keypads    INT S    INT SK    INT SCR  multifunction keypad  offering the partition keypad functionality      The keypads are available with keys backlight in various color versions  The color version is  indicated by an additional letter symbol included in the keypad designation  e g  INT S GR      green backlight  INT S BL     blue backlight      36 User Manual SATEL       INT SCR                                                                                                          Partition keypads  INT S and INT SK keypads are shown without flaps         6 1 Description of partition keypads    6 1 1 LED indicators   Color   Function description  ON     partition armed  ON or blinking     alarm or alarm memory             blinking     trouble or trouble memory          Table 4  Description of LEDs in partition keypads     1 Information on the armed status can be extinguished after the time period defined by  the installer     If the installer has enabled the GRADE 2 option       the    LED will not inform about the alarms         blinking of the TAALED means that there is a trouble in the system  some zones are  bypassed  or that there was an alarm     The    gt  and  M LEDs blinking alternately indicate that the system is waiting for the  second cod
25. arming procedure will be initiated as soon as  the code is entered and confirmed with the   key     5 4 2 Full arming the selected partitions    1  Enter the code and confirm with the   key      Using the V key  scroll through the menu until you find the ARM function      Press the   key  A list of partitions which can be armed will be displayed      Using the V and A keys  find in the list the partition which is to be armed      Press any digit key  The   symbol in the upper right hand corner will be replaced by the iii  symbol  see also section SELECTION FROM THE MULTIPLE CHOICE LIST p  15     6  Repeat the steps 4 and 5 for the next partitions which are to be armed    7  Having selected the partitions which are to be armed  press the   key     You can also arm the selected partitions using of the ARM SELECTED function  available upon  entering the code and confirming with the   key  but only when none of the partitions  accessible to you is armed and the keypad is signaling no alarm     OT AOON    5 4 3 Arming in the selected mode  1  Enter the code and confirm with the   key     SATEL INTEGRA 23       2  Using the V key  scroll through the menu until the ARMING MODE function is found    3  Press the   key  A list of arming modes will be displayed  see  description of the ARMING  MODE function  p  17     4  Using the A and V keys  find the arming mode which is to be activated  and then press  the   key    5  When the ARM function is displayed  press the   key  Proceed in t
26. artitions operated from the keypad       none of the partitions accessible to the user is armed       there is no alarm    Two functions are available in the menu    Arm all arming all partitions   Arm selected arming selected partitions    5 2 2 Disarming menu    The disarming menu will be displayed if       the user is authorized to disarm the partition       the user has access to a number of partitions operated from the keypad       atleast two partitions accessible to the user are armed    Two functions are available in the menu    Disarm all disarming all partitions   Disarm selected disarming selected partitions    5 3  Code  k     user menu    After you enter the code and confirm using the   key  the user menu will be displayed  The  list of available functions depends on the user authority level  as well as the system status  and configuration  In order to exit the user menu  press the   key  The keypad will quit the  menu automatically  if 2 minutes have elapsed since the last keypress     Upon entering the code and confirming with the    key  a message about the need to  change the code or a service note may be displayed     5 3 1 Functions list    j The functions available after entering the service code have been highlighted with  white text against black background  Highlighted with a frame are functions available    to the administrators     View clear  al  view cleared alarms from selected partition zones  restore system after verified alarm   Disarm disarm se
27. ary zones   start new test for fire and technical zones   view test results   abort test   clear test results   test battery and 60  TECHN    BATTERY LOW zones   start manual test transmission   start test transmission to station 1     main phone number  start test transmission to station 1     backup phone number  start test transmission to station 2     main phone number  start test transmission to station 2     backup phone number  start messaging test   display information on answered tel  call   check proximity card number   start mimic board test   view master users   display keypad name   display inf  on DLOADX program file with control panel data  display information on control panel firmware version   display inf  on ABAX syst  firmware  only INTEGRA 128 WRL   display information on GSM telephone  only INTEGRA 128 WRL   display inf  on ETHM 1 module IP address and MAC number  display information on module firmware version   start time synchronization   set installer access time   open selected door controlled by system   control outputs   start service mode   take over service mode    start local programming   finish local programming   start communication via external modem   start communication via 300 bps modem   start CSD communication  only INTEGRA 128 WRL   start GPRS communication  only INTEGRA 128 WRL   start communication via Ethernet with DLOADX program  start communication via Ethernet with GUARDX program    1  Using the V and A keys  find the required sub
28. connected to the MONO SWITCH  BI SWITCH   REMOTE SWITCH  SHUTTER UP and SHUTTER DOWN type outputs  see  section OUTPUTS  CONTROL p  34     Service mode     available to the installer  Initiates the service mode    Take SM over     available to the installer  If the service mode has been initiated from another  keypad  it can be  taken over   i e  the service menu can be displayed on the keypad  on  which the TAKE SM Over function has been started    Downloading     the following functions are available in the submenu    Start DWNL RS     available to the installer  Enables the control panel to be programmed  locally by means of the DLOADX program    Finish DWNL RS     available to the installer  Ends the local programming of control panel    Start DWNL MOD      enables remote programming through an external modem  analog   GSM or ISDN  by means of the DLOADX program    Start DWNL TEL     enables remote programming through the built in 300 bps modem   using the DLOADX program     22 User Manual SATEL       Start DWNL CSD     enables remote programming through the built in GSM communicator     using CSD technology  by means of the DLOADX program  Planer ae  Start DWNL GPRS     enables remote programming through the built in GSM    communicator  using GPRS  General Packet Radio Service   by means of the DLOADX  program  SLWANNSCHZE  ZCA LE    ETHM 1     DloadX     enables remote programming through the Ethernet  TCP IP  by  means of the DLOADX program  The ETHM 1 module with fir
29. control panel or any other control panel to  which a module with keyfob support is connected  ACU 100  ACU 250  INT RX or  INT RX S   a keyfob can be assigned to the user  which will allow to operate the system  remotely  The user may have up to 2 keyfobs  the APT 100  supported by the ABAX  system  and the 433 MHz  supported by the INT RX or INT RX S modules      Buttons     the button functions are available  if a keyfob has been assigned to the user  It is  possible to assign a zone to a keyfob button or combination of buttons  The zone will be  violated upon pressing the button   combination of buttons  The assigned zone should not  exist physically    Events  RX    Events  ABAX      if a keyfob has been assigned to the user  it is possible to  define whether pressing the appropriate keyfob button will result in logging an event which  informs that the keyfob has been used     ABAX confirmation     if an ABAX system keyfob has been assigned to the user  it is  possible to determine the status of which outputs will be presented on the keyfob LEDs on  pressing any button     Name     individual user name     5 8 1 User types    The name as used in the keypad is shown in the square brackets  The description includes  only the codes  but the information provided below applies to all identifiers assigned to the  user     Normal     basic type of user   One time  Single      the user will get one time access     Renewable  Time renewable      the user has access to the system f
30. ction     Events signaled by sounds      Only installer selected events are signaled   5 short beeps     zone violation  CHIME    Very short beeps     door open too long     8 2 Functions available from code lock    Depending on the user type and authority level  as well as the code lock settings  entering  the code and confirming it with the   or   key will result in         unlocking the door  activating the relay        changing over the status of 25  BI SWITCH type outputs       turning on the 24  MONO SWITCH type outputs       guard round confirmation       enabling temporary partition blocking   The installer can permit triggering alarms from the keypad  To trigger an alarm  do the  following   fire alarm     press the  INT SZ     INT SZK  key for approx  3 seconds   medical  auxiliary  alarm     press the 0 key for approx  3 seconds   panic alarm     press the       INT SZ     INT SZK  key for approx  3 seconds  The    installer defines whether the triggered alarm will be loud  setting off the loud alarm  signaling  or silent  without loud signaling      The installer can permit changing own code by means of the code lock  Proceed in the same  way  as when changing the code by means of the partition keypad  see  p  39                  9  Confirming voice messaging    The installer can configure the control panel so that confirmation of listening to the voice  message be required  If there is no confirmation  the control panel can connect many times  for playback of the
31. d at the keypad               ccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 38  6 2 6 Code changing zasad a a ca chess ase ese ps vm ase      ESEA EDn EO 39   7  Usingthe entry Sy a Cg a Se GH a Se CH a GC ae tees 39  7 1 LED indicators zez A AO a Aa FO a A PO POP PEARCE 39  T2  6UMASG  RINJSK    a ARR RAA GA A Gi A A GG 39  7 3 Functions available from the entry keypad                     eeeeeeeee eee aaa aaa aaa 39  8  UsiNgthe code l6ER abo A ROEE GO ROGERS AEO scr eee aes 40  8 1 Description of code LOCKS OE GEO GOO 40  8 1 1 LED NMG NNN ca he OLECKO sees eueereeececececeree 40  812 PEJS t aa NA ONA A ONE NOA AO Z OO A OAI 40  8 1 3 Sound signaling  ssiri AE AEAEE EEEE EAEE 41   8 2 Functions available from code lOCK                  s  ss eseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeseeeeeeeeeeeeees 41  9  Confirming voice MeSSAaQGING                           2       seeeeeeeeeeeeeeeeeeeeeeeeeeeeceeeeeeeceneneneneeeeeeenes 41  10  Call answering and telephone control                     asaasaa saa aaa aaa wawa aaa aaa aa aaa ka AAAA AAAA AAAA 42  10 1 Answering phone CallS aa EEEE EEEE EO 42  10 2 Telephone COMMOl casio wii OE 43  10 3 Audio alarm verification zosia 43  11  SMS control SMISEN  cece eteceeseneeseecesseteeseeseeseeees 43  12  Operating the alarm system by means of keyfob                     seeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeaes 44  13  Manual update history                  cccccccceeeesseeeeeeceeeeeeeesseeeeeeeeeeeeeeaeaceeeeeeeseeseeaaassesereeesenenees 45    14
32. default CONS aaa ia a nisaire ERSE ses cess cass R wa   5  4 3 Operation under duress a A O A a OAK 6  5  Operating the alarm system by means of LCD keypad                            eaaaaaaaaaaaaaaaaaaaaaa   6  5 1 Keypads description ua A A EA KOGA 6  5 1 1 LED US o a R Aa ZPA bwa EOE EEEE 6  5 1 2 LED indicators  RR R ORO OR ORO r peade Earn p r RCA AGFA A 8  5 1 3 BOS eb a R   E E O E ED ORDO ODZEW 9  5 1 4 Built in proximity card reader aaa akad dada Ewki dwa 9  5 1 5 Sound signaling sassa0002504000440050 0009000050 00000000 O ost 9   5 2   Code       arming   disarming menu                   e    eee oaza aaa aazn awa 10  5 2 1 AMINA MENU ce OOOO AE ORO A OOOO A OO 10  5 2 2 DEGMI  Y MAW zs oo E ai a O GG a Roz 11   5 3   802 SZCZ dinz NANA 11  5 3 1 FinciGN R Reo ona O RA RSE RSE SRA RS OR GR REG 11  5 3 2 Starting TUNCIONS ee A OPER pb 14  5 3 3 MENUSNANEOE sisena OE R   iaaa iaa niaaa 15  5 3 4 Entering data by means of the LCD keypad                   ccccccceeeeeeeeeeeeeeeeeeeeeeeeeees 15  5 3 5 Description of user functions wo Goin A kia 17   o    PANINI E E E EE 22  5 4 1 Full arming without partition selection            eneee 22  5 4 2 Full arming the selected partitions           eneee 22  5 4 3 Arming in the selected mode        ssnoosoensesennnsessesssseseesssresrrrerereneerserrrerrerrerreeenne 22  544    QUICK AMN e eee E 23  5 4 5 Denial  of ann  sai AR R R ae ae ee 23  5 4 6 Failure of arming procedure    id wodo wio   d 23  5 4 7 Shortening the exit dela
33. dicators    Only the    gt  LED is used  Blinking of the LED indicates that the delay activation time  countdown is running  disarming has no effect on the LED blinking      7 2 Sound signaling    The installer can disable the sound signaling or replace it by blinking of keypad  backlight    During operation  the keypad can generate the following sounds    1 short beep     pressing any digit key  confirmation that code has been entered or card has  been read    3 short beeps     confirmation of delay activation    4 short and 1 long beeps     confirmation of the guard round or execution of the control for  24  MONO SWITCH or 25  BI SWITCH type outputs    3 pairs of short beeps     the user should change his her code    2 long beeps     unknown code card    3 long beeps     activation the delay is impossible  the partition is disarmed or the delay has  already been started  or the function is unavailable    Additionally  the keypad can audibly signal the DELAY ACTIVATION TIME     7 3 Functions available from the entry keypad    Depending on the user type and authority level  keypad settings and alarm system status   entering the code and confirming it with the    or   key  presenting the proximity card  will  result in        activating the delay in partition for 3  INTERIOR DELAYED type zones        changing over the status of 25  BI SWITCH type outputs        turning on the 24  MONO SWITCH type outputs        guard round confirmation     40 User Manual SATEL       8  Using t
34. e during the two code arming   disarming     All LEDs blinking in turn indicate that there is no communication with the control panel     6 1 2 Keys    The keys enable authorization of the user by means of code and running of the functions  available from the partition keypad     SATEL INTEGRA 37       In the INT SCR keypad  the button is additionally available  It controls the keypad OC  type output  the output is active  when the button is pressed      6 1 3 Built in proximity card reader    The INT SCR keypad has a built in reader which enables operation by means of proximity  cards  proximity tags or other 125 kHz passive transponders   The installer determines  if the  reader will be operated     Presenting the card is interpreted in the same way as entering the code and confirming with  the   key  Holding the card  for approx  3 seconds  is interpreted in the same way as  entering the code and confirming with the   key     6 1 4 Sound signaling    Beeps generated when operating    The installer can disable the sound signaling or replace it with blinking of the keys  backlight     1 short beep     pressing any digit key  confirmation that code has been entered or card has  been read    2 short beeps     acceptance of the first code during two code arming   disarming    3 short beeps     signaling of          starting the procedure of arming  if no exit delay time has been programmed for the  partition  this is equivalent to arming          disarming and or alarm clearing
35. ed for Grade 2   reset 43  RESETABLE POWER SUPPLY type outputs  clear latched outputs   end door fire opening    enable disable CHIME in keypad   block zone violation signal  on 11  CHIME type outputs  edit timers   program partition timers   block expander tampers   enable disable permanent installer access  make user editing available to installer   make system control available to installer  enable disable permanent DLOADX access   set address of computer with DLOADX program  set address of computer with GUARDX program  erase service note    check current state of partitions  check current state of zones  check module supply voltage    14    User Manual SATEL       Radio devices  Temperatures  Zones test   New   Burglary zones  Fire tech zones   View results   Finish test   Clear results  Manual tr  test  Station 1A test  Station 1B test  Station 2A test  Station 2B test  Messaging test  Answering test  Prox  card test  CA 64 PTSA test  View masters  Keypad name  File in DloadX  Panel version  STM prg version  GSM IMEI V sig   IP MAC ETHM 1  Modules version  Time synchron                    Service access          Open door  Outs control    Service mode  Take SM over    Downloading    Start DWNL RS  Finish DWNL RS    Start DWNL MOD   Start DWNL TEL  Start DWNL CSD  Start DWNL GPRS  ETHM 1     DloadX  ETHM 1     GuardX       5 3 2 Starting functions    check radio signal level for wireless devices  check temperatures measured by ATD 100 detectors    start new test for burgl
36. eep     countdown of exit delay  if the time is shorter than 10 seconds  only  the final sequence of short beeps will be generated      A sequence of 7 beeps of diminishing duration  repeated every few seconds      countdown of auto arming delay     2 short beeps every seconds     countdown of entry delay   2 short beeps every 3 seconds     signaling a new trouble   Continuous beep     alarm    Long beep every second     fire alarm     5 2  Code       arming   disarming menu    Information given in the section below do not apply to users having the SIMPLE USER  right  see p  25     After you enter the code and confirm it with the   key        amessage on the need to change the code or a service note may be displayed         alarm will be cleared     if the user is authorized to clear the alarm and there is an alarm  in the system         one partition will be disarmed     if the user is authorized to disarm the partition  has  access to only one partition operated from the keypad and that partition is armed  or has  access to many partitions  but only one partition is armed         one partition will be armed     if the user is authorized to arm the partition  has access to  only one partition operated from the keypad and that partition is disarmed         the arming disarming menu will be displayed     5 2 1 Arming menu    The arming menu will be displayed if       the user is authorized to arm the partition     SATEL INTEGRA 11           the user has access to a number of p
37. es     running the function will result in a temporary deactivation of the  43  RESETABLE POWER SUPPLY type outputs  thus making it possible to reset the alarm  memory for detectors supplied from those outputs  e g  fire detectors      Clear latched outputs     allows to turn off some of the control panel outputs for which the  LATCH option is enabled  as well as the 9 DAY ALARM  12  SILENT ALARM  and 116  INTERNAL SIREN type outputs    Fin f door open     restores the normal operating mode in all modules executing the access  control functions  in case of fire  the doors controlled by these modules may be  automatically unlocked      SATEL INTEGRA 19       Change options     the following functions are available in the submenu     Keypad chime     turns on off the chime signal in the keypad  signaling violations of  selected zones      Outputs chime     allows to block the chime signal from selected partitions on the  11  CHIME type output     Timers     allows to program parameters of the timers  the editing of which is permitted by  the installer     Partition timers     allows to program the partition timers  see  PROGRAMMING THE  PARTITION TIMER p  32      No expanders tamper alarms     allows to temporarily disable the expansion module  tamper supervision  In case of any problems with the expansion modules  report the fact  to the installer     Permanent service access     the option is available to the master user  administrator   If  enabled  the installer has permane
38. full arming   1    full arming   bypasses   2    arming without interior   3    arming without interior and without entry  delay     CODE  K     enter the user menu  User menu shortcuts   Change own code  Users  Masters   New user  New master   Edit user  Edit master   Remove user  Remove master   Zone bypasses  Inhibit  Isolate  Events  Selected events  All events  Set time  System state  Outputs control  Service mode  Downloading  Start DWNL RS  Finish DWNL RS  Start DWNL MOD   Start DWNL TEL  Start DWNL CSD  INTEGRA 128 WRL   Start DWNL GPRS  INTEGRA 128 WRL   ETHM 1     DloadX  ETHM 1     GuardX       Ez   OO  O        O         O       gt      blinking     service mode started    1  group  numbers  1 32   addresses 00 1F   2  group  numbers  33 64   addresses 20 3F   3  group  numbers  65 96        4  group  numbers  97 128    LED OFF         LED ON                                                                                                                   we w a 20 26 25 26 2 28 29 80 o 32    Sates  integra  1 P mc   3der   k U CA  Ng  m      4 gni 5 int Eme   0 O  m   as  Tras   Bun   Guo   4    RZ  sA NX                               Shortcut keys  press for approx  3 seconds    1     check zone status   4     check partition status   5     view alarm log   6     view trouble log   7     view current troubles    8     CHIME signal ON OFF   9     toggle display between standby mode and partition  status mode   0O  trigger medical  aux  alarm         trigger fire a
39. g data can be defined for the user     Code     a sequence of digits for authorization of the user when using keypads and code  locks  The control panel supports codes consisting of 4 to 8 characters  however the  installer can define the minimum length of the code     Telephone code     a sequence of digits for authorization of the user when using the  functions of telephone call answering and telephone control  see  section CALL ANSWERING  AND TELEPHONE CONTROL p  42      Partitions     partitions to which the user has access  i e  he is authorized to arm or disarm  them  clear alarms etc       Type     see  section USER TYPES p  26   User schedule     parameter for the SCHEDULED type code  see  section USER TYPES p  26      Validity time     parameter for the RENEWABLE  TEMPORARY or SCHEMATIC type codes  see   section USER TYPES p  26      Blocking time     parameter for the BLOCKING PARTITION type code  see  section USER TYPES  p  26    Rights     define which functions can be used by the user  The following rights  permissions   are available       Arming      Disarming      Disarm  when other user arm  Can alw disarm      if the user does not have this right   he she can only disarm the system if it was armed by him her      Partition alarm clearing  Alarm clearing       Object alarm clearing  Object al clr        Other objects alarm clearing  Other al clr        Telephone messaging canceling  V msg clearing       Auto arming defer  Arm deferring       First code for tw
40. g station  the control panel may repeat attempts every few minutes to send the code  or to cease the attempts to send the code until a next event occurs     SATEL INTEGRA 5       4  Authorization of users    Operation of the alarm system is possible after the user authorization  which allows the  control panel to verify that the user is authorized to perform the given operation  The  authorization can be done on the basis of     e code    e proximity card  125 kHz passive transponder  which can be in the form of card  tag  etc     e DALLAS iButton  chip     e keyfob     You can not assign the same identifier  code  proximity card  DALLAS iButton or  keyfob  to two users     For safety reasons  different people should not use the same identifier     The installer can configure the panel so that it will not accept codes that contain less  than three digits  e g  1111 or 1212  or consist of consecutive digits  3456      The installer may permit the use of certain functions without the need for user  authorization     Using an invalid code  proximity card or DALLAS iButton three times may       trigger an alarm       block the keypad   reader for 90 seconds     4 1 Authorization with two identifiers    The INT KLCDR and INT KLFR keypads and the INT SCR multifunction keypads have a  built in proximity card reader  The installer can configure these devices so that the user has  to use two identifiers for authorization  the code and the card  The function to be executed  after the a
41. he   key to return to  the USER submenu     5 8 3 Edit user    The user can edit the users in relation to which he she is the superior  For example  if  the user A has created the user B  and the user B has created the user C  then the  user A can edit the users B and C     The user being edited may not be granted a higher authority level than the person who  is editing such a user    Enter the code and confirm with the   key   Press the 2 key twice  The list of users will be displayed    Using the V and A keys  find in the list the user who is to be edited    Press the   key  The list of functions for defining the user s parameters will be displayed    Using appropriate functions  modify the user s parameters    Press the   key    When a prompt appears  asking you if the changes are to be saved  press the 1 key     A message will inform you that the user has been modified  Press the    key to return to  the list of users     PPOR RZ    28 User Manual SATEL       5 8 4 Removing a user    The user can remove the users in relation to which he she is the superior  For  example  if the user A has created the user B  and the user B has created the user C   then the user A can remove the users B and C     Enter the code and confirm with the   key    Press in turn the 2 and 3 keys  The list of users will be displayed    Using the V and A keys  find in the list the user who is to be removed   Press the   key  A message will inform you that the user has been removed   Press the   key 
42. he code lock    The basic task of the code lock is to execute the access control function  Supervise a single  door      SATEL offers the following code locks   INT SZ   INT SZK     The code locks are available with keys backlight in various color versions  The color version  is indicated by an additional letter symbol included in the code lock designation  e g   INT SZ GR     green backlight  INT SZ BL     blue backlight      8 1 Description of code locks                                                                                                                                              Fig  5  Code locks        8 1 1 LED indicators    Function description  ON     code lock is operated by the control panel       ON     door unlocked       blinking     door open             Table 5  Description of the code lock LEDs       All LEDs blinking in turn indicate that there is no communication with the control panel     8 1 2 Keys    The keys enable user authorization by means of a code and starting of the functions  available from the code lock     SATEL INTEGRA 41       8 1 3 Sound signaling    Beeps generated when operating    The installer can disable the sound signaling or replace it by blinking of the keypad  backlight    1 short beep     pressing any digit key or confirmation that code has been entered    4 short and 1 long beeps     confirmation of door unlocking or execution of another function    2 long beeps     unknown code card    3 long beeps     unavailable fun
43. he same way  as for  the full arming of selected partitions  steps 4 7      5 4 4 Quick arming    The installer can permit the arming without user authorization  The partitions indicated by the   installer will be armed    1  Select the arming mode  press one of the keys  O     full arming  1     full arming    bypasses  2     arming without interior  3     arming without interior and without entry delay     2  Press the   key  The arming procedure will begin     5 4 5 Denial of arming    The installer can program the control panel so that the arming procedure could not be  started  if        azone is violated in the partition        there is a trouble in the system  including tamper         there was a verified alarm   The keypad will inform you about the refusal to arm by means of a message specifying the  cause for refusal     1 If after a verified alarm the arming is impossible  the installer must be called  The  arming will only be possible after the installer intervention  see  description of the  SYSTEM RESET function  p  17      Bypassing violated zones when arming   If the arming procedure could not be started  and a message on the display informs you that  there are violated zones  you can review the list of such zones upon pressing the 2 key  To  scroll through the list  use the V and A keys  Pressing the 4 key will allow you to bypass the  given zone  A message on the display will prompt you to press the 1 key to confirm that the  zone is to be bypassed     Forced
44. his will bring you back to the SELECTED submenu    6  Using the VW key  scroll down the menu until you find the View function    7  Press the   key  The last one of the selected events which occurred in the system will be  displayed    8  Using the A key  scroll through the list of previous events     In addition to defining the event types to be displayed  the SELECT PART  function can  also be used to indicate the partitions to which the events are to refer     If the GRADE 2 option is enabled in the system  the installer or administrator can use  the VIEW GRADE2 function instead of the ViEw function  In such a case  the events  selected among those required by the EN 50131 standard for Grade 2 will be  displayed     5 11 4 Way of presenting events    The following information is shown in the display upper line       date and time of event occurrence         additional information on the events in shortened form  e g  number of partition  zone   user  timer  expander  keypad  etc     Event description is displayed in the lower line     If no key is pressed for a few seconds  additional information on the event will be displayed   e g  name of partition  zone  user  timer  expander  keypad  etc   After a few seconds  the  event description will be displayed again  and so on     Pressing the    key enables the manual toggling between description of the event and  additional information on the event     Pressing the 4 key when the event description is displayed will allow you 
45. ing the selected events    aaa aaa oi A A PA rererere 32  5 11 4 Way of presenting events    32  5 12 Programming the partition timer    zeszli etd cere eta cael cae ea cee eee ee 32  5 139 ZOnE tesStihg saska kad FE i i R A ad RZA Ra ad A Aa aS tren 33  5 14 Outputs control o odda LO Zd A O LG AG PLO 34  5 14 1 Controlling the MONO SWITCH type of output           eee eea 35  5 14 2 Controlling the BI SWITCH type of output           eee a 35  5 14 3 Controlling the REMOTE SWITCH type of outputs                   ccceeeeeeeeeeeeeeeeeeeeeeeeeees 35  5 14 4 Controlling the roller shutter ouiputs               sssasssa saa aaa aaa aaa wawa wawa s AAA 35   6  Using the partition keypad                       eeee eee aaa aaa aaa aaa aaa aaa aaa aaa aaaaa aaa aaazaaaaaeaaaaaa aa aaa 35  6 1 Description of partition keypaQS                            ee eee aaa aaa aaa aaa aaa aaa aaa aaaaaaae aaa ania aa 36  6 1 1 CEED INdICatOrS RE EKO OCE SOLEO SOC EEEE EE 36  62 Keys nee a 36  6 1 3 Built in proximity Card reader                cccccccccseeeeeeeeeeeeeeceeeeeeeeseeeeeeeeeeseeaeesseeeeeeess 37  6 14    SANREMO ee ee ae 37   6 2 Functions available from the partition keypad                 ccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 38   oA NCCU EEEE 38  622   Codejf ttt ttt Ss to te ttl pt tne 38  6 23  OLUIERGMINO eee een eee E a ee ee ee 38  6 2 4 Triggering the alarm from keypad                        e  eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeneeeneeeee 38  6 2 5 Silencing the alarm soun
46. interior and without entry delay  allows the users to stay in the  protected area     to be used when nobody else is to enter the protected area      this  arming mode is similar to the previous one  but the delayed zones operate as the  instant ones  no entry delay     Cancel 1st code     if the partition is armed disarmed by means of two codes and the first   code has already been entered  the user can still cancel the consent to arming disarming     18 User Manual SATEL       Change own code     allows the user to change his her own code   Change telephone code     allows the user to change his her own telephone code     Change prefix     available to the administrator  if the use of prefixes in the system has been  made available by the installer  the prefix length has been defined   It enables to program  the prefixes and the time to remind about the need to change the prefix  Each code will  have to be preceded by a prefix     normal     for everyday use  By default  it consists of a suitable number of digits O  e g  if  the determined prefix length is 4  the default prefix is 0000      DURESS     for use  when the user has been forced to enter the code  Using the code will  trigger a silent alarm  By default  it consists of a suitable number of digits 4  e g  if the  determined prefix length is 3  the default prefix is 444      Users     the following functions are available in the submenu   New user     allows to create a new user  see  section ADDING NEW USER p  27  
47. larm   O     trigger panic alarm       
48. lected partitions   Clear alarm clear alarm    Clear other al   Abort voice m   Arm   Arm  2 codes   Disarm  2codes   Defer auto arm  Set auto arm d   Arming mode  Cancel 1st code  Change own code  Change tel code          Change prefix          Prefix normal  Prefix duress  Recall time    clear alarm in other objects  cancel telephone messaging  arm selected partitions   start two code arming   start two code disarming  postpone the auto arming   set auto arming postpone time  select arming mode   cancel consent to two code arming disarming  change own code   change own telephone code    set normally used prefix  set duress prefix  set time to remind of the need to change prefix    User Manual SATEL       New user    Code   Telephone code  Partitions   Type   Schedule  Existence time  Bypass time  Rights   Keypads etc   New prox  card  Rem  prox  card  New DALLAS  Remove DALLAS  New RX key fob  Rem  RX key fob  Button 1   Button 2   Button 3   Button 4   Button 1 and 2  Button 1 and 3  Events  RX   New ABAX keyfob  Rem ABAX keyfob  Button 1   Button 2   Button 3   Button 4   Button 5   Button 1 and 5  Events  ABAX   Confirm   ABAX   Name    add new user   set code   set telephone code   assign partitions available to the user  select type of code   select time schedule   set code validity time   set bypass time   assign rights   assign modules available to the user   add proximity card   remove proximity card   add DALLAS iButton   remove DALLAS iButton   add 433 MHz keyfob 
49. menu or function  The currently selected  submenu or function is indicated by the arrow      on the left hand side    2  Press the b   or   key to enter the submenu  the  lt  key allows to exit the submenu  or  start the function     SATEL INTEGRA 15       5 3 3 Menu shortcuts    You can use shortcuts for quick access to some menu elements  submenus  functions    Press the suitable digit key  or combination of keys  to enter a submenu or start a function   Shown below is the list of submenus and functions available by using shortcuts  The  shortcuts are shown in square brackets    1  Change own code   2  Users    21  New user    22  Edit user    23  Remove user    If the installer is not authorized to edit the users  the shortcuts beginning with the digit  2 will allow the installer to start the function from the MASTERS submenu      4  Zone bypasses   41  Inhibit   42  Isolate   5  Events   51  Selected events   52  All events   6  Set time   7  System state   8  Outputs control   9  Service mode   0  Downloading   01  Start DWNL RS   02  Finish DWNL RS   03  Start DWNL MOD    04  Start DWNL TEL   05  Start DWNL CSD  only INTEGRA 128 WRL    06  Start DWNL GPRS  only INTEGRA 128 WRL    07  ETHM 1     DloadX   08  ETHM 1     GuardX    5 3 4 Entering data by means of the LCD keypad    Data are saved to the control panel if you press the   key  in some keypads  the D key is  also available  whose function is exactly the same   The   key enables exiting the function  without savi
50. mware version 1 03  or  newer  must be connected to the control panel     ETHM 1     GuardX     enables remote operation and administration through the Ethernet   TCP IP  by means of the GUARDX program  The ETHM 1 module with firmware version  1 03  or newer  must be connected to the control panel      5 4 Arming    This section describes the operations that must be carried out by the user from the keypad in  order to initiate the arming procedure  The arming procedure is ended at the running out of  the exit delay time  if the procedure is ended successfully  the system becomes armed     see  also FAILURE OF ARMING PROCEDURE p  23   If the exit delay time is O  the system becomes  armed instantly     The installer can configure the alarm system so that the arming functions will not be  available after tamper  A message on the display will indicate that the user must call  for service  The arming functions will not be available until the service code is entered  and confirmed with the   key     5 4 1 Full arming without partition selection   The arming without partition selection is possible when none of the partitions to which the  user has access is armed and the keypad is not signaling any alarm    1  Enter the code and confirm with the   key     2  When the ARM ALL function is displayed  press the   key  The arming procedure will be  initiated in all partitions which are accessible to the user and are operated by the keypad     If the user can only arm one partition  the 
51. ng any changes    Described below are general rules for entering data  however they may be different as  regards some functions     Selection from the single choice list   Shown in the upper line of display is description of the function  and in the lower one     the  currently selected item  You can scroll through the list of items  using the direction keys  V   down  and A  up   The b and 4 keys are not used     Selection from the multiple choice list    The functions that allow you to make multiple choice can be identified by an additional  symbol situated at the right hand side of the display     16 User Manual SATEL             displayed item is not selected   option is disabled     Press any numeric key to change the currently displayed symbol to another one  To scroll the  list of items  use the V  down  or A  up  key     For some functions  pressing the b or 4 key will switch the keypad into the graphic  programming mode  The Ki and   symbols are used to present on the display the current  status of up to 32 items available in the given function  these can be e g  zones  outputs   timers  etc    Additionally  in case of zone bypassing  the HH symbol is used  The  gt  gt  key moves  the cursor to the right  and the 4 key to the left  If the list of items is longer than 32  pressing  the  gt  key when the cursor is placed over the last item will display the next list  and pressing  the  lt  key when the cursor is placed over the first item will display the previous list
52. nt access to the alarm system  which  among other  things  enables the control panel to be programmed by using LCD keypad or DLOADX  program     Enabling PERMANENT SERVICE ACCESS option will clear the installer access time  programmed with the SERVICE ACCESS function  On the other hand  programming the  installer access time will disable the PERMANENT SERVICE ACCESS option     Service can edit     the option is available to the master user  administrator   If it is  enabled  the installer can add  edit and delete users in the administrator s object     Service arm disarm clear bypass     the option is available to the master user   administrator   If it is enabled  the installer can arm disarm the system  clear alarms  and bypass zones in the administrator object     Permanent DLOADX access     the option is available to the master user  administrator   If  it is enabled  the control panel can be programmed by means of the DLOADX program   irrespective of whether or not the installer has access to the alarm system     DloadX IP     enables programming the address of the computer  on which the DLOADX  program is installed  The address must be set if the control panel is to initiate  communication with the DLOADX program through Ethernet  using the TCP IP protocols   see  description of the ETHM 1     DLOADX function  available in the DOWNLOADING  submenu   It can be entered as a name or IP address     GuardX IP     enables programming the address of the computer  on which the 
53. nt times on different days of  the week     12 Press the   key     13 If you have selected the daily variant  the function will allow you at once to program the  arming time  and upon pressing the A or V key     the disarming time  Upon confirmation  with the   key  you will be brought back to the list of options and functions     14  If you have selected the weekly variant  you will be brought back to the list of options and  functions  where functions will appear to enable programming of the arming   disarming  time for each day of the week  in the same way as for daily timer        Programming the value 99 99 means that the partition will not be armed   disarmed     15  After the arming time has been programmed  an additional function will be displayed   which allows you to define which arming mode will be activated by the given timer  By  default  the timer activates the full arming mode  If another arming mode is to be  activated  run this function  for the daily timer or individually for each day of the week   and  using the A and W keys  select another arming mode  Confirm  using the   key    16  Having programmed all parameters  press the     key    17 When a prompt appears  asking you if the changes are to be saved  press the 1 key     5 13 Zone testing    Within periodic inspections of the security alarm system  the detectors must be checked for  proper functioning  The zone testing function will allow you to do it without triggering the  reaction normally expected 
54. ntrol panel zones    GSM IMEl v sig      allows to check the level of signal received by the GSM telephone  antenna  individual identification number of the telephone  and the telephone version     The A and V keys are to be used for scrolling through the displayed information   INTEGRA 128 WRL    IP MAC ETHM 1     displays the local IP address  MAC number and public IP address of  the ETHM 1 module connected to the control panel  use the V and A keys to scroll the  information      Modules versions     allows to check the firmware versions for devices connected to the  control panel communication buses     Time synchronization     allows to manually start synchronization of the control panel  clock and the time server  It applies to the control panel to which the ETHM 1 module is  connected  The address of time synchronization server must be programmed in the  control panel     The function is unavailable  if the time synchronization is running  Automatic time  synchronization takes place every day at 05 30     Service access     available to the master user  administrator   Allows to program the time  period of installer access to the alarm system  The time is programmed in hours   Programming the value 0 means the installer will have no access    Open door     allows to unlock the door controlled by the alarm system  modules executing  the access control functions  or activate the 101  CARD READ     EXPANDER type outputs    Outputs control     allow to control the devices 
55. number is to be read  press twice the keyfob button according to the  instructions displayed on the keypad  When the keyfob number is displayed  press the    key    5  If the keyfob number is to be entered  enter it from the keypad  and then press the   key    6  You will be brought back to the list of functions for defining the user parameters  Instead  of the NEW RX KEY FOB   New ABAX KEYFOB function  the REM  RX KEY FOB   REM ABAX  KEYFOB function will be available  Additionally  some functions appear to allow you to  configure the keyfob     Prior to assigning the zones to buttons   combinations of buttons  consult the installer     Numeration of the keyfob buttons and LEDs is described in section OPERATING THE  ALARM SYSTEM BY MEANS OF KEYFOB  p  44      SATEL INTEGRA 29       7  Using the W key  find the BUTTON 1 function in the list  and then press the   key    8  Using the V and A keys  select which zone is to be violated on pressing the 1 button in  the keyfob  you can also enter the zone number from the keypad   and then press the    key    9  Repeat the steps 7 and 8 for other buttons   combinations of buttons which are to be  used    10  Using the W key  find the EVENTS  RX    EVENTS  ABAX  function in the list     11 Press the   key  The list of buttons   combinations of buttons will be displayed  In the  upper right hand corner of the display  an additional symbol is located    El     pressing the button   combination of buttons is written to the event log  defa
56. o codes partition  Enter 1st code       Second code for two codes partition  Enter 2nd code       Access temporary blocked partitions  Block p access       Change access code  Code changing       Users editing      Zones bypassing  Zones inhibit       Zone isolation  Zones isolate       Clock setting      Trouble state checking  Troubles view        Event log reviewing  Events viewing       Detectors resetting  Zones resett        Options programming  Options chang        Access to menu TEST  Tests       Downloading starting  Downloading       Access to BI  amp  MONO outputs  Outs control       System state review in GUARDX  GuardX using       Resetting outputs  Clr latch outs         Simple user     having entered the code  confirmed with the   key  the user never  selects the partitions which are to be armed   disarmed  All partitions the user has  access will be armed   disarmed     26 User Manual SATEL           Administrator     the user has access to the menu functions which are reserved for the  administrator    Keypads etc      additional modules from which the user will be able to operate the system   proximity card arm disarm devices  partition keypads  code locks  reader expanders      Proximity cards   DALLAS chips     if the proximity card   DALLAS iButton reader is used in  the system  a proximity card   DALLAS iButton can be assigned to the user  which will  allow the user to operate the system by means of readers     Keyfobs     in case of the INTEGRA 128 WRL 
57. o get information on the partition status  armed  disarmed   Owing  to the telephone control function  it is possible to control the REMOTE SWITCH type outputs  using the telephone     10 1 Answering phone calls    1  Establish connection with the control panel  using one of the following methods  consult  the installer to learn which method is supported by the control panel      single call     call the telephone number of control panel  The control panel will answer the  call after the number of rings programmed by the installer     double call     call the telephone number of control panel  Hang up after the number of  rings programmed by the installer  Call again within three minutes  The call will be  answered by the control panel immediately   Establishing connection will be signaled by three short beeps   2  Enter the telephone code on the telephone keypad  4 short beeps and 1 long beep will  confirm that you have got access to the call answering function  If the entered code is  invalid  this will be signaled by the control panel by two long beeps     1 If you make a mistake when entering the code  enter the 4 digits anyway  and when  the control panel signals that the code is wrong  enter the correct code     After entering three wrong codes  the control panel will hang up     In case of a single call  if       no code has been entered and the connection is terminated       an invalid code has been entered and the connection is terminated   the control panel will ans
58. ode after  you press the 9 key for approx  3 seconds again    If some predefined events occur  additional messages may appear on the display  e g   arming  disarming  auto arm delay countdown  entry exit delay countdown  alarm  etc     Entering the user code  i e  the user authorization  will open a menu containing the functions  that are available to the user  The functions are presented in two lines  The currently selected  function is indicated by the arrow on the left hand side  How the function related information  is presented depends on the specific character of the given function     The way of display backlighting is programmed by the installer     SATEL INTEGRA 7       INT KLCD   INT KLCDR INT KLCDK                                                 7 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32                                                    integra                      U  O BA   4  EJ Ce  LD    e  7     GH  M    3                             7  6E                CHJ Lo                                                                                    INT KLFR    7 PQRS 8 TUV 9 WXYZ  Gs Em Es  lt       go og  cj                Fig  1  Keypads with flap        8 User Manual SATEL       INT KLCDS INT KLCDL                                                                                                                                                                                                                      Fig  2  Keypads without flap        5 1 2 LED indica
59. on  signaling of entering the user menu   submenu or function    3 short beeps     signaling of       starting the arming procedure  if no exit delay has been programmed  this is equivalent   to arming         disarming and or alarm clearing    turning output off    disabling chime signal in the keypad  using the 8 key     10 User Manual SATEL           toggling the display between the standby mode and the partition status presentation  mode  using the 9 key       exiting the function and returning to the menu after confirmation of the data entered   4 short beeps and 1 long beep     signaling of       turning output on       enabling chime signal in the keypad  using the 8 key       ending the function and exiting the user menu after confirmation of the data entered   1 long beep     signaling of       violated  bypassed zones when arming       fault of the vibration detector  10  24H VIBRATION type zone was not violated during the  vibration detector test run upon starting the arming procedure    2 long beeps     invalid code card  function not available or exiting the function without  confirmation of the data entered  e g  by using the   key    3 long beeps     unavailable function     Events signaled by sounds    Only installer selected events are signaled     Alarms are being signaled throughout the time programmed by the installer     5 short beeps     zone violation  CHIME      Long beep every 3 seconds  followed by a series of short beeps for 10 seconds  and 1 long b
60. on violation  which is of particular importance in case of  permanently armed zones    Enter the code and confirm with the     key    Using the V key  scroll through the menu until you find the TESTS submenu    Press the   key    Using the W key  scroll through the menu until you find the ZONES TEST submenu    Press the   key    When the New function is displayed  press the   key     Select whether burglary zones or fire and technical zones will be tested  and then press  the   key     8  Select the partitions in which zones will be tested  see  section SELECTION FROM THE  MULTIPLE CHOICE LIST p  15      9  Specify the test duration  maximum 50 minutes  and press the   key     10  Define  whether violation of a zone is to be signaled by chime in the keypad  the signaling  will be enabled upon pressing any digit key     the   2 symbol will be displayed      A PER oS    34 User Manual SATEL       11 Press the   key  The zone test will start     Beginning of the zone test in any partition will start the test mode in all ABAX system  wireless devices which are used together with the control panel  the wireless detectors  will signal violations by means of LEDs      If any detectors with remote LED ON OFF function are connected to the control panel   you can switch on the LEDs in them for the test duration  the installer can configure  the control panel so that this will take place automatically at the beginning of the test      You can terminate the zone test before expiration of
61. or a defined period of  time  The user validity time should be defined  Before the validity time expires  the control  panel will prompt the user to change the code  After the code has been changed  the  validity time will run from the beginning     Temporary  Time not renew       the user has access to the system for a defined period of  time  The user validity time should be defined  After the validity time expires  the user will  have no access to the system     Duress     code to be used in hold up and duress situations  Use it to trigger a silent alarm  and send the event code to the monitoring station       Mono    output operating  Mono outputs      code for control of the MONO SWITCH type  outputs        Bi    output operating  Bi outputs      code for control of the BI SWITCH type outputs     Blocking partition  Part temp block       the code enables access to the armed partitions   Using the code will block the armed partition s   the partition zones will not trigger the  burglary alarm   The blocking time is defined individually for each user within the range  from 1 to 109 minutes  If  however  the time of bypassing for guard round is defined for the  partition and its duration is longer  the blocking will last longer     SATEL INTEGRA 27       Cash machine zones bypassing  Acces to cash m       the code to be used to unblock  access to the cash dispenser  the 24H CASH MACHINE type zones will be temporarily  bypassed in the partition      Guard     using this code
62. propriate services will be notified   etc    which may deter the potential burglars     The SATEL s goal is to continually upgrade the quality of its products  which may result in  alterations of their technical specifications and firmware  The current information on  the introduced modifications is available on our website    Please visit us at   http   www satel eu    The declaration of conformity may be consulted at www satel eu ce    Factory default codes   Service code  12345  Object 1 master user  administrator  code  1111    The following symbols may be used in this manual       note   A   caution     Changes made to the firmware version 1 12    System  operation    User functions    New keypads     INT KLFR     LCD keypad with mechanical keys and built in proximity  card reader     INT TSG     touchscreen keypad   INT TSI     touchscreen keypad   New function  CHANGE TEL CODE    Zone test duration can be up to 50 minutes  earlier  up to 25 minutes      The IP MAC ETHM 1 function allows to check the public IP address of  the ETHM 1 module     New rights       SIMPLE USER      ADMINISTRATOR          2 User Manual SATEL  CONTENTS   1  Generalerna A 020 204000400 DTD RO OS 4  2  Technical reliability of the alarm system                   4    44 4 euuueeeeee aaa aaa aaa wawa a 4  3  Alarm system operating COSIS ea ea oO AERO AEK KORE GEEK REKE 4  4    Authorization Of WIS OS    Ra OG oi AG R a R GREG 5  4 1 Authorization with two identifiers      ccnti ee 5  4 2  Factory 
63. r from the given keypad    Arm  2 codes      allows to initiate arming of the partitions which require entering 2 codes    Disarm  2codes      allows to initiate disarming of the partitions which require entering 2  codes    Defer auto arming     available when auto arming delay countdown is running  It allows to  postpone by a programmed time period the auto arming of the partition in which the auto   arming delay countdown is running  Entering just zeros will block the auto arming function   until the next auto arming time     Set auto arming delay     available when the auto arming delay is programmed for at least  one partition and the auto arming delay countdown is not currently running in that partition   It allows to postpone by a programmed time period the auto arming of the partition    Arming mode     allows to select the arming mode which is to be used  the shortcut key is  shown in square brackets      0  full arming  to be used after everybody has left the protected area      1  full arming   bypasses  allows the users to stay in the protected area      the zones for  which the BYPASSED IF NO EXIT option is enabled by the installer will be bypassed     2  arming without interior  allows the users to stay in the protected area         interior zones  3  INTERIOR DELAYED zone type  will be disarmed       violating the exterior zone  8  EXTERIOR zone type  will trigger a silent alarm       violating another alarm zone will trigger a loud alarm     3  arming without 
64. roll through the menu using the W key until the ARM  2 CODES    DISARM  2CODES   function is found     3  Press the   key  Proceed in the same way as for the full arming of selected partitions   steps 3 7     4  If the installer has not set the code validity at 60 seconds  specify the code validity and  confirm with the   key     Prior to expiration of the code validity  the user entering the second code must arm   disarm  the partition using the     e LCD keypad  see  section ARMING or DISARMING AND ALARM CLEARING    e partition keypad   code      e reader  read in of proximity card or DALLAS iButton      The installer can configure the alarm system so that the second code will have to be  entered on another LCD keypad  partition keypad  etc     5 7 Triggering the alarm from keypad   The installer can permit triggering alarms from the keypad  To trigger an alarm  do the  following    fire alarm     press the   key for approx  3 seconds    medical  auxiliary  alarm     press the O key for approx  3 seconds     panic alarm     press the cj key for approx  3 seconds  The installer defines whether the loud  panic alarm  setting off the loud alarm signal  or the silent panic alarm  without the loud  signal  will be triggered     5 8 Users    The users can be added  edited and removed by    e master user  administrator     e installer  if the SERV  CAN EDIT option is enabled by the administrator    e user  if granted the USERS EDITING right      SATEL INTEGRA 25       The followin
65. sending the transmission  messages are displayed to inform about the currently  performed operation  The function is useful when starting the reporting or in case of any  reporting trouble    Messaging test     allows to test the messaging function  Upon starting the function    1  Enter the number of the telephone  consecutive number on the telephone list    2  Press the V key    3  Enter the number of voice message    4      Press the   key  The control panel will call the indicated number and play back the  message     vooo  gt   I     D TEBMraAt O  1    SATEL INTEGRA 21       Answering test     if this function is started  information on the number of rings and going  off hook is displayed when answering the telephone call    Proximity card test     allows to check the number of proximity card and establish to whom  it belongs  if the card belongs to a user of the system     CA 64 PTSA test     allows to test the mimic board    View masters     available to the administrator  It makes it possible to check in which  objects the master users are created    Keypad name     allows to check the given keypad name    File in DLOADX     displays the date and time of writing the data to the control panel by  means of the DLOADX program and the name of file with control panel data     Panel version     displays information on the control panel firmware version    STM program version     displays information on the program version of the processor  used to operate ABAX system and co
66. ser Manual SATEL           send the USSD codes to the operator of SIM card installed in the module  e g  to check  the card account status or recharge it   The answer received from the operator is  forwarded in the form of SMS message to the telephone number from which the control  command was sent     When sending the USSD codes  the SMS message must have the following form   xxXXXX Vyyy     where  xxxxxx  is the control command and  yyyy  is the USSD code supported by the GSM  network operator     The SMS message may contain several control commands     If correctly programmed by the installer  the control panel will confirm execution of the control  commands by means of SMS messages sent to the telephone number from which the control  command was received     12  Operating the alarm system by means of keyfob       Fig  7  T 4 keyfob  433 MHz keyfob   A     numeration of keyfob buttons        SATEL INTEGRA 45       For the INTEGRA 128 WRL control panel or any other control panel to which the ACU 100   ACU 250  INT RX or INT RX S module is connected  you can control the system using the  keyfob  The user can have up to 2 keyfobs        bidirectional APT 100 keyfob     supported by the ABAX system  INTEGRA 128 WRL  control panel  ACU 100 controller  firmware version 2 00 or newer  or ACU 250  controller         433 MHz keyfob     supported by the INT RX or INT RX S module    One keyfob enables execution of up to 6 functions  For each keyfob  functions to be executed  upon pre
67. ssary to periodically carry out a functional test of the alarm system  Check that the  control panel responds to violation of individual detectors  that their coverage areas are not  obstructed  that there is a reaction to opening protected windows  and that sirens and  telephone messaging work normally     Detailed instructions on the system testing should be provided by the installer  It is  recommended that the installer carry out periodic maintenance of the alarm system  when  ordered by the user     It is in the user s interest to foresee and prearrange the procedures to be followed when the  control panel signals an alarm condition  It is important to know how to verify the alarm and  identify its source on the basis of keypad information  and take appropriate measures  e g   to  organize evacuation     3  Alarm system operating costs    The control panel can inform the users and the monitoring station about the status of  protected facility  Realization of these functions by means of the phone line or GSM means  financial costs  The amount of the costs incurred depends on the amount of information sent   A failure of telephone links  as well as an incorrect programming of the control panel  may  result in increased costs  due to making of excessive number of calls      Please inform the installer  which is a priority  to deliver information at any cost  or to prevent  excessive costs  For example  after an event code has failed to be sent successfully to the  monitorin
68. ssing a button   combination of buttons  and for the APT 100 bi directional keyfobs  also information to be displayed on the keyfob LEDs  are individually assigned  see  section  ADDING KEYFOB p  28      Fig  8  MPT 300 keyfob  433 MHz keyfob   A     numeration of keyfob buttons  The button  designated with digit 6 corresponds to the combination of buttons 1 and 3 in other 433 MHz  keyfobs        13  Manual update history    Firmware  version   2013 08 e Information on INT TSG keypad has been added  p  6     e Note about the user having SIMPLE USER right has been added  p  10     e List of user functions has been supplemented  p  11     e Description of CHANGE TELEPHONE CODE user function has been added    p  18     e Description of SIMPLE USER right has been added  p  25     e Description of ADMINISTRATOR right has been added  p  26     e Information on maximum duration of zone testing has been modified  p  33     e Section  Audio alarm verification  has been added  p  43      2013 12 A e Information on the INT KLFR  p  5  6 and 9  and INT TSI  p  6  keypads has  been added     Introduced changes             e Description of IP MAC ETHM 1 user function has been modified  p  21      14  Brief description of operating the system from keypad     A    blinking     trouble or trouble memory   Grade 2     trouble or trouble memory  bypassed zones or  alarm    ON     all partitions operated by the keypad are  armed  blinking     some partitions are armed       Quick arming    O    
69. the functions available in the menu  Additionally  if you press and hold down the selected digit  keys for approx  3 seconds  you can  if the keypad has been so configured by the installer      1   check the state of zones     check the state of partitions     view the alarm log     view the trouble log     view the current troubles     enable disable chime signal in the keypad     toggle the display between the standby mode and partition state display mode   The other keys enable you to       enter the user menu  after entering the code      cancel the started operation     COON OO R      or Ok   arm  disarm and clear alarm  after entering the code      start the selected function     confirm the entered data    lt A YP  navigate through the display  scroll through the displayed messages  functions  and options  and move the cursor      run the installer selected functions  after entering the code      cw   trigger the fire alarm   O   trigger the medical  auxiliary  alarm        trigger the panic alarm     5 1 4 Built in proximity card reader  The INT KLCDR and INT KLFR keypads can be operated by means of proximity cards     proximity tags or other 125 kHz passive transponders   The installer defines which functions  can be executed after presenting or holding the card     5 1 5 Sound signaling    Beeps generated when operating      The installer can disable the sound signaling     1 short beep     pressing any number key    2 short beeps     confirmation of command executi
70. the letter case  press W key     SATEL INTEGRA 17       Shown on the left side in the upper line of the display is information about the letter case    ABC  or  abc   it will be displayed after pressing any key and will be visible for a few seconds  after the last keystroke     The  gt  key moves the cursor to the right  and the 4 key     to the left  The A key deletes the  character on the left side of the cursor     5 3 5 Description of user functions    View cleared alarms     available  if the user did not view the violated zones after alarm  clearing  It allows to check which zones triggered the alarm  After completion of the  viewing  the function is no longer available    System reset     available to the installer  if the option REQUIRED SYSTEM RESET AFTER VERIFIED  ALARM is enabled  and a verified alarm took place  After occurrence of the verified alarm  it  is necessary to reset the system by means of this function  in order to make re arming  possible    Disarm     allows to disarm the partitions accessible to the user from the given keypad    Clear alarm     allows to silence the alarm    Clear other alarms     allows to silence the alarms from other objects  to which the user has  normally no access    Abort voice messaging     terminates the telephone messaging     The messaging can be cancelled automatically together with alarm clearing  The   messaging cancellation rules are defined by the installer    Arm     allows to arm the partitions accessible to the use
71. to return to the list of users      8 5 Adding proximity card   DALLAS iButton      When adding or editing a user  run the NEW PROX  CARD   NEW DALLAS function      Using the V and A keys  select how the card   iButton is to be added  The number of  card   iButton can be read by a selected reader  device equipped with a reader  or  entered manually    3  Press the   key    4  If the number of card   iButton is to be read  read in the card   iButton twice  following the  instructions appearing on the keypad display  When the read number of card   iButton is  displayed  press the   key    5  If the number of card   iButton is to be entered  enter it from the keypad  and then press  the   key    7  You will be brought back to the list of functions for defining the user parameters  Instead   of the NEW PROX  CARD   New DALLAS function  the REMOVE PROX  CARD   REMOVE   DALLAS function will be available  Press the   key     6  When a prompt appears  asking you if the changes are to be saved  press the 1 key     Nag BRYN    Proximity cards   DALLAS iButtons are added to the master users  administrators  in  the same way     5 8 6 Adding keyfob    1  When adding or editing a user  run the NEw RX KEYFOB   NEW ABAX KEYFOB function   depending on which keyfob is to be added     2  Using the V and A keys  select how the keyfob is to be added  The number of keyfob  can be read during transmission by a device supporting keyfobs or entered manually    3  Press the   key    4  If the keyfob 
72. to see further  additional information on the event  shown in a shortened form     Using the 4 or  gt  gt  key will block the automatic toggling between description of the event and  additional information on the event     After the list of events has been scrolled through with the use of the A or W key  the  automatic toggling between description of the event and additional information on the event  will be restored     5 12 Programming the partition timer    The partition timer automatically arms   disarms the partition    Enter the code and confirm with the   key    Using the V key  scroll through the menu until you find the CHANGE OPTIONS submenu   Press the   key    Using the    key  scroll through the menu until you find the PART  TIMERS function   Press the   key  The list of partitions will be displayed     B     P     SATEL INTEGRA 33       6  Using the V and A keys  find in the list the partition for which the timer is to be  programmed    7  Press the   key    8  When the ACTIVE option is displayed  make sure it is enabled  the    f symbol is displayed  next to the option   If it is not enabled  the   symbol is displayed next to the option   press  any digit key    9  Using the W key  scroll through the menu until you find the TYPE function    10  Press the   key    11 Using the V and A keys  select the timer type   everyday     if the partition is to be armed   disarmed at the same time every day     weekly     if the partition is to be armed   disarmed at differe
73. tors    LED Color Function description     o green ON     all keypad operated partitions are armed  blinking     some keypad operated partitions are armed or exit delay  countdown is running                   rB  red ON or blinking     alarm or alarm memory   L2   r ellow blinking     trouble or trouble memor   A   j y    Q    green blinking     service mode is entered    4 green if zone status is being presented or the keypad is switched to graphic    programming mode  see  section SELECTION FROM THE MULTIPLE   CHOICE LIST p  15   two LEDs indicate which data set is being  displayed  see  table 2    Table 1  Description of keypad LEDs              LED     Data type i i f Information  left side upper right side lower   numbers 1 32  numbers 33 64  numbers 65 96  numbers 97 128  system addresses 0 31  00 1F HEX   system addresses 32 63  20 3F HEX     Table 2  Information presented by the B   LEDs           Zones Outputs          Expanders                Information about the armed state can be extinguished after a time period defined by  the installer     If the installer has enabled the GRADE 2 option         the    LEDs provide information about alarms only after the code has been  entered and confirmed with the   key     SATEL INTEGRA 9           blinking of the T   LED means that there is a trouble in the system  some zones  are bypassed  or that there was an alarm     5 1 3 Keys    The keys designated with digits and letters enable entering the code and data  when using  
74. ult  setting        pressing the button   combination of buttons is not written to the event log    12  Define whether pressing the button   combination of buttons will be written to the event log   see  section SELECTION FROM THE MULTIPLE CHOICE LIST p  15   and then press the   key    13 For the APT 100  ABAX  keyfobs  use the V key to find the ABAX CONFIRMAT  function in  the list  and then press the   key    14 A list will be displayed showing the outputs which have been assigned by the installer for  confirmation  maximum 8   Select up to 3 of them  see  section SELECTION FROM THE  MULTIPLE CHOICE LIST p  15   Upon pressing any keyfob button  information on the status of  selected outputs will be presented on the keyfob LEDs for a few seconds  Thus you can  get confirmation that the function has been executed or information on the current status  of the system     The installer can define the list of outputs by means of the keypad  ABAX CONFIRMAT   function  SERVICE MODE    STRUCTURE    HARDWARE    EXPANDERS    ABAX CONFIRMAT    or a computer with the DLOADX program   Keyfobs ABAX  window     15 Press the   key    16  Press the     key    17 When a prompt appears  asking you if the changes are to be saved  press the 1 key       Keyfobs are added to the master users  administrators  in the same way     5 8 7 Removing keyfob    1  When adding or editing a user  run the REM  RX KEY FOB   REM ABAX KEYFOB function   depending on which keyfob is to be removed   The appropriate
75. uthorization depends on the second identifier         code     whether it will be confirmed by using the   key or the   key       card     whether it will be presented only or held     4 2 Factory default codes    By default  the following codes are preprogrammed in the control panel   service code  12345  object 1 master user  administrator  code  1111    The factory default codes make it possible to assign individual codes to consecutive persons  who are to use the alarm system  see  section USERS p  24      The factory default codes should be changed as soon as possible using the CHANGE  OWN CODE function available in the user menu     The control panel can inform the user that the code change is necessary  if the code is  known to other users     The master code should not be used on a daily basis because of the risk of its being  captured  It is recommended that the administrator enter for himself an ordinary user s  code     6 User Manual SATEL       4 3 Operation under duress    When acting under duress  the DURESS type code must be used instead of the normal user  code  see section USER TYPES p  26      5  Operating the alarm system by means of LCD keypad    SATEL offers the following keypads for INTEGRA control panels    INT TSG     touchscreen keypad    INT TSI     touchscreen keypad    INT KSG     LCD keypad with touch keys    INT KLCD     LCD keypad with mechanical keys    INT KLCDR     LCD keypad with mechanical keys and built in proximity card reader   INT KLCDK
76. wer no calls for the next few minutes  It enables e g  a fax to  be connected after the control panel   3  Within up to 15 seconds  enter the 2 digit partition number  e g  01  07 or 15   The control  panel will inform you about the partition status by means of sound signals   3 short beeps     partition disarmed   4 short and 1 long beeps     partition armed   If no key is pressed on the phone for 15 seconds  the control panel will hang up     SATEL INTEGRA 43       4  Upon pressing in turn the 0 and   keys on the telephone keypad  the control panel will  hang up     10 2 Telephone control    1  Get access to the phone call answering function  steps 1 2 in section ANSWERING PHONE  CALLS     2  Within up to 15 seconds  press in turn the 2 and   keys on the telephone keypad  4 short  beeps and 1 long beep will confirm that you have got access to the telephone control  function    3  Within up to 15 seconds  enter the 2 digit number of the remote switch  e g  01  07 or 15    The control panel will inform you about the switch status change by means of sounds     3 short beeps     the switch has been turned off   4 short and 1 long beeps     the switch has been turned on     The operating mode of the REMOTE SWITCH type output depends on how the output has  been configured by the installer        4  Upon pressing in turn the 0 and   keys on the telephone keypad  the control panel will  hang up  You can also press the 1 and   keys to return to the phone call answering  function    
77. y time wear s sowy awa kop E GEE ESEE EE AE SE EEEE EEEE EA ESEE pzy 23   5 5 Disarming and alarm clearing oasis RWE EE Ewe 24  5 5 1 Alarm clearing without disarming ena aoi ai ai io 24   36  Two code arming   GISANMING   see   6655 6e556 gt SG0E EEG EE SE EEE EEE EE EPEE EEEE EEEE CP EE EPEE EEEE EYES EEEE EEEE EEE 24  5 7 Triggering the alarm from Keypad esscez eco Oo ee eee 24  DO    MUS S a o a a da r AK O A EA A EE AA io Sai 24  5 8 1 MU Z aaa 26  302  Adding NEW USE mcs a e 27  5 8 3 EditUS ET peco a a WEG 27  5 8 4 Removing US ee a ee see A ER ee eee eee eee 28  5 8 5 Adding proximity card   DALLAS iButton  0000      eee eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 28  5 0960 Adding Keyf D scssi reece cenceccescereececerstecsuee aae raet oae Paat Paat Paet Paat Paat Paat iat Pian Eiee eee 28  5 8 7 Removing Keyio Drc Ao 29   5 9    Master users  administrators  seek EEEE eska kE Eck Eee kie sk Eee Eeee EEEE Eee kE EEEE GE EEEE EEG EEEE EL 30  5 10 Zone bypassing zakk a OJ OO A OE 30  5 10 1 Zone inhibiting IE  30  2 102  LONEISOlAtNG secrecion iee rece duce bees ee iae raet raar Eet Pae aet Paat Paat Piat aat Paat Paat Panes 30  510 3  UnDypaSSiNg  mame me mem me a ere a a a eee EEEE 31    5 11 Viewing Iho even IGG ceccceccccctvecteecececceectvectueceveceuestvectuereseceuestiectueseuecetesttecttesesesecestee 31    SATEL INTEGRA 3       5 11 1 VeWNGGAISENNN RA on A GAGA GA R A A R A aa R a A FaZa AAA REA 31  5 11 2 Viewing the events required for Grade 2    eeen 31  5 11 3 View
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
スーパー クロース プロジェ クション システム SCP716W  File - MayerWaren International SA de CV  BENDIX BW2625 User's Manual  Bedienungsanleitung de Operating instructions en Mode d  Bandridge Notebook Surge Protector  Le coin des fournisseurs  USER MANUAL  Chicago Electric 42417 User's Manual  Kingston Technology ValueRAM 8GB DDR3-1333MHz ECC  BPMphysio User Guide    Copyright © All rights reserved. 