Home
Helena - Handicare
Contents
1. 8 into the end of the rail Tighten bolts with a 17mm open end wrench Image 2 M10x25 Miox16 N NOTE Make sure the longer bolt 10 is in serted into the primary rail s safety hole Image 3 4 MANUAL SystemRoMedic Assemble in the following order End stop Traverse rail carrier End stop To prevent the traverse rail carrier from gliding along the rail during as sembly of the second support leg anchor it to the support leg that has already been assembled We recommend anchoring the traverse rail carrier with the help of an end stop image 4 When assembly is com plete slide the end stop to the other end of the rail and leave it in place Mount the second primary rail on the other support leg Insert the end stop screws into the pre drilled holes image 3 Fit the screw covers Mount the crossbeams to the first pair of support legs Tighten bolts with a 17mm open end wrench Mount screw covers on bolt heads image 5 Attach the second pair of support legs to the first cross beam image 6 Then mount the other crossbeam between the pairs of support legs SystemRoMedic MANUAL Mount secondary rail on traverse rail carrier assembly Insert the rail over the square nuts on the traverse rail carrier Tighten with a 17mm open end wrench image 7 Max 50mm NOTE Ensure that secondary rail overhang does not
2. exceed 50mm Risk for instability Image 7b NOTE Make sure the long bolt 10 is inserted into the secondary rail s safety hole image 7c Finally mount the following on the secondary rail in the following order End stop Lift unit with carriage End stop Screw covers on all visible bolt heads Adjust Helena to the desired height by first loosening the locking knobs on the support leg pairs one pair at a time and then carefully rocking the lift stand Mount the locking Knobs in appropriate holes A NOTE Maximum height must not be exceeded The red warning label must not be visible when the desired height has been set Risk for instability Image 8 6 MANUAL SystemRoMedic Final inspection Inspect Helena for signs of damage Check to ensure that Helena is standing securely on the floor so that it does not lean and that the support legs are adjusted to the same height Check to ensure that all locking knobs and bolts are securely tightened The lift unit must be inspected according to the procedure for periodic inspection for the respective lift unit Keep the manual where it is easily accessible for users of the product Using the product AN important information e Helena must be assembled according to the assembly instructions provided with the stand e Helena may only be used indoors and on a level floor e Lifting accessories must be properly trial fitted and tested in relatio
3. of model and material is determined by the patient s functional capacity and the situations in which the product is to be used For further information on slings and other lifting accessories see SystemRoMedics manuals and brochures Positioning aids SystemRoMedic includes a wide range of functional comfortable high quality assistive devices for positioning that can be adapted for different types of lifting and for patients with different needs Articlenumber for a complete lift stand Helena 3x3 lift stand 50300009 Helena 4x3 lift stand 50300010 Helena 5x4 lift stand 50300011 Maintenance Helena must undergo thorough inspection at least once per year This must be done by authorized service personnel and in accordance with the periodic inspection for Helena Repairs and maintenance may only be done by authorized personnel using original spare parts Cleaning When necessary clean the lift using warm water or rubbing alcohol Do not use cleaning agents containing phenol or chlorine as this may damage the material 8 MANUAL SystemRoMedic Technical information Dimensions Lr Wr ro ig ry T pa i f i an an yout ty B L L Wi i W Max Height H Height to Rail Hr Max Lenght L nner Length Li Functional Length Max Width W nner Width Wi Functional Width Primary Rail Wr Tota
4. CC Helena Manual English SystemRoMedic Helena 3x3 art no 50300009 Helena 4x3 art no 50300010 Helena 5x4 art no 5030001 1 bes P SWL 285kg 628lbs Helena is a freestanding lift stand which in combination with a traverse rail and lift unit functions as a stationary patient ift It is particularly suitable in cases where the need for a stationary lift is occasional or in situations where it is not pos sible to install a permanent overhead rail system Helena is made of aluminium which makes it very light in relation to its high lifting capacity Handicare s SystemRoMedic product series includes a range of lifts slings and other accessories SystemRoMedic adopts a holistic approach to patient transfers and is organized in four categories transfer positioning support and iing Functional inspection Visual inspection Inspect Helena and lift unit functions regularly Check to ensure that material is free from damage Before use Check to ensure that the lift stand and lift unit are correctly assembled Check all mounts and safety latches Ci Always read the manual Always read the manuals for all assistive devices used during a transfer Keep the manual where it is accessible to users of the product The lift system may only be used by persons who have received instruction in the operation of it Manual nr 709 En Ver 1 130702 handicare Ta
5. ble of contents Assembly Component parts Assembly of lift stand Final inspection How to use the product Important information Safe working load Accessories Maintenance Technical information Dimensions 3 7 4 7 MANUAL SystemRoMedic Assembly Component parts 4 1 4adjustable legs 2 4 corner pieces 3 2 crossbeams 4 2 primary rails See table for available lengths 5 1 secondary rail 6 1 traverse rail carrier set 7 6 end stops 8 6 rail covers 9 6 bolts M10x16 not pictured 10 6 bolts M10x25 not pictured 11 16 bolts M10x85 not pictured 12 16 screw covers not pictured 13 4 mounting fixtures not pictured 14 8 washers M8 not pictured 15 6 end stop screws M8x70 not pictured 16 6 locking nuts M8 not pictured 17 12 screw covers M8 not pictured SystemRoMedic MANUAL Assembly of lift stand Place the corner pieces on the top ends of the legs as illustrated Mount through bolts 11 and locking nuts Tighten with two 17mm open end wrenches not included Mount screw covers on bolt heads Mount legs pair wise so that the carrier handles are on the outside Image 1 Affix the mounting fixtures loosely to the top sides of the corner pieces using bolts 9 10 and washers 13 Mount the first primary rail by inserting it into the mounting fixture on the corner piece Before inserting the rail all the way in press a rail cover
6. help people has always been and will continue to be the driving force of innovation We love easy transfers Contact your local distributor if you have any questions about the product and its use See www handicare com for a complete list of distributors Always make sure that you have the right version of the manual The most recent editions of manuals are available for downloading from our website www handicare com NS handicare Handicare AB Veddestav 15 Box 640 SE 175 27 Jarfalla SWEDEN Tel 46 0 8 557 62 200 Fax 46 0 8 557 62 299 E mail info handicare se Internet www handicare com
7. l weight of system Weight of the heaviest part Secondary Rail Lr 50300009 50300010 50300011 50300009 50300010 50300011 8x3 4x3 5x4 mlbs mlbs ilbs mm kg mm kg mm kg 2040 2490 80 3 98 80 3 98 80 3 98 2708 2708 3708 106 6 106 6 3157 4157 5157 124 3 163 7 2989 3989 4989 117 7 196 4 2870 3870 4870 152 4 191 7 ee SystemRoMedic MANUAL 10 MANUAL SystemRoMedic SystemRoMedic MANUAL 11 SystemRoMedic For 25 years we have applied ourselves wholeheartedly to developing smart and easy to use assistive devices for easy transfers and to making life and work easier for both patients and personnel in the care sector Experience innovation and training are the basis for SystemRoMedic a total solution for every imaginable transfer situation Transfer products for moving patients between locations Positioning products for repositioning in the same location Support products that provide mobility support Lifting products adapted for lifting The philosophy behind SystemRoMedic is to prevent occupational injuries while improving the patient s sense of inde pendence and dignity Through a combination of training and a complete range of transfer assistive devices SystemRoMedic offers the means to improving both the work environment and the quality of care while enabling significant cost savings Our mission to
8. n to the patient s needs and functional ability e Do not leave the patient unattended during a transfer situation e Under no circumstances may max load be exceeded See section on safe working load e To ensure optimal function Helena must be inspected regularly See section on maintenance Warranty applies only if repairs or alterations are done by an authorized technician Ensure that secondary rail overhang does not exceed 50 mm Risk for instability e Maximum height must not be exceeded Risk for instability e Make sure the longer bolt M10x25 is inserted into the safety hole when mounting the primary and secondary rails Safe working load Different products on the same lift system lift unit slingbar sling scales and other lifting accessories may have different allowable safe working loads The lowest allowable safe working load always determines the safe working load of the assembled system Always check the safe working loads for the lift and accessories before use Contact your dealer if you have any questions SystemRoMedic MANUAL 6 Accessories Lift units SystemRoMedics lift units are available in different models and ver sions stationary or portable The choice of model is determined by the required lifting capacity the location and situations in which the lift is to be used and the patient s individual needs Slings SystemRoMedic slings are available in different fabrics and models The choice