Home
iFORA user manual
Contents
1. Meter Storage e Storage conditions 20 C to 60 C 4 F to140 F below 95 relative humidity e Always store or transport the meter in its original storage case e Avoid dropping and heavy impact e Avoid direct sunlight and high humidity Caring for Your Test Strips e Storage conditions 2 C to 32 C 35 6 F to 89 6 F below 85 relative humidity Do NOT freeze e Store your test strips in their original vial only Do not transfer to another container e Store test strip packages in a cool dry place Keep away from direct sunlight and heat e After removing a test strip from the vial immediately close the vial cap tightly e Touch the test strip with clean and dry hands e Use each test strip immediately after removing it from the vial e Write the opening date on the vial label when you first opened it Discard remaining test strips after 3 months e Do not use test strips beyond the expiry date This may cause inaccurate results e Do not bend cut or alter a test strip in any way e Keep the strip vial away from children since the cap and the test strip may be a choking hazard If swallowed promptly see a doctor for help For further information please refer to the test strip package insert Important Control Solution Information e Use only our control solutions with your meter e Do not use the control solution beyond the expiry date or 3 months after first opening Write the opening date on t
2. POSSIBLE CAUSE WHAT TO DO Error in performing Read instructions thoroughly and the test repeat the test again Control solution vial Shake the control solution was poorly shaken vigorously and repeat the test again Expired or Check the expiry date of the contaminated control solution control solution Control solution that Control solution meter and test is too warm or strips should be at room too cold temperature 20 C to 25 C 68 F to 77 F before testing Defective test strip Repeat the test with a new test strip Reference Plasma Glucose Range The meter provides you with plasma equivalent results Time of day Normal plasma glucose range for people without diabetes mg dL Fasting and lt 100 mg dL 5 6 mmol L before meal 2 hours lt 140 mg dL 7 8 mmol L after meals Source American Diabetes Association 2010 Clinical Practice Recommendations Diabetes Care 33 Supplement 1 S1 S100 Please consult your doctor to determine a target range that works best for you Caring for Your iDiamond Meter Set To avoid the meter and test strips attracting dirt dust or other contaminants please wash and dry your hands thoroughly before use Cleaning 1 To clean the meter exterior wipe it with a cloth moistened with tap water or a mild cleaning agent then dry the device with a soft dry cloth Do NOT rinse with water 2 Do NOT use organic solvents to clean the meter
3. and Troubleshooting Reference Plasma Glucose Range Caring for Your iDiamond Meter Set iDiamond Meter Specifications 0 Symbols Getting Started About the iDiamond Blood Glucose Monitoring System 6 7 8 9 1 Dock Connector Test Strip Slot S Test Strip Absorbent Hole Apply a drop of blood here The blood will be automatically absorbed Confirmation Window This is where you confirm if enough blood has been applied to the absorbent hole in the strip Test Strip Handle Hold this part to insert the test strip into the slot Contact Bars Insert this end of the test strip into the meter Push it in firmly until it will go no further NOTE The iDiamond monitor should only be used with iDiamond Test Strips Using other test strips with this meter can produce inaccurate results ATTENTION The front side of test strip should face up when inserting test strip Test results might be wrong if the contact bar is not fully inserted into the test slot How to Install and Update the iFORA Diabetes Manager App iDiamond is designed to be used in conjunction with the iFORA App available on iTunes or the App Store for free download You must be connected to the internet to download the App The App Store can be accessed through the iTunes or by tapping the App Store icon on your iOS devices iFORA is designed to assist you in easy blood glucose testing recording tracking and monitoring It
4. enter The first page you will see is the 7 day data record of the blood glucose test results under the four measuring modes If you select a particular option then it will show individual trend graph Also you can select 2 3 or 4 options to show individual trend graph at the same time a r mM Q F Data Plan FAQ s Settings ata Plan Settings 30 Days a ah 7 Data Plan ACK Settings ata Pla s Settings 2 Zoom in or out to review 7 14 and 30 day data record stored in each measuring mode in the memory The first entering page is 7 days you can select the enlarge button on the top right corner to zoom out for 14 days and 30 days view NOTE e Control solution results are NOT included in the day average Reviewing Target Pie Chart Glucose Control Ratio in Percentage Percentage display Current 7 14 30 Day Page Indications Select the Target Pie Chart mode from the Floating Menu Select Target Pie Chart in Floating Menu to enter You will see the current 7 day of glucose control ratio in percentage under 4 measuring modes You can see the percentage in 3 duration times of current 7 14 30 days to quickly switch between simply swipe to the left or to the right Current 7 14 30 Day Color controls Green glucose level is in good control during this time Red glucose level is too high during this time Yellow glucose level is too low during this time PLA
5. is simple and intuitive to use for better understanding of your current condition and to achieve better diabetes control System Requirement e iOS version 5 0 1 or higher To find more product information about FORA Diamond Series please visit our website www foraminisite com diamond Updating When new features are added to the iFORA App the App Store will notify you automatically Please perform the updates accordingly to provide you with the latest features that we have developed in your best interest Important Health related Information e Severe dehydration and excessive water loss may cause readings which are lower than actual values If you believe you are suffering from severe dehydration consult a healthcare professional immediately e f your blood glucose results are lower or higher than usual and you do not have any symptoms of illness first repeat the test If you have symptoms or continue to get results which are higher or lower than usual follow the treatment advice of your healthcare professional e Use only fresh whole blood samples to test your blood glucose Using other substances will lead to incorrect results e f you are experiencing symptoms that are inconsistent with your blood glucose test results and you have followed all the instructions given in this owner s manual contact your healthcare professional e We do not recommend using this product on severely hypotensive individuals or pati
6. 2011 12 25 AM 09 15 AN 2 Swipe left or right to recall the individual test results stored in the memory An example 98 mg dL 5 4 mmol L lily Settings Data an Q s Settings 3 Note by Category 3 1 Add Notes You can select different categories or type in personal note to add new ones for that individual measurement You also can add new one as a frequent used canned message for adding notes more convenient ra Ate excessive desserts ra Ate fatty food k ppp ggggg L _ olwhetAtt ypul ofe te a larger portion Aie excessive desserts p BROEN 123 epee return qrtsett Add New wle R T vJu 0 noocogona Bne0o00 3 2 Delete Notes You also can delete the note if needed a In canned message management page b In data record page Reviewing Record List Record Titles ei a e Page Indications 20 Teed 05 14 AM ie Enlarge to see each entry in detail 1 Select the Record List mode from the Floating Menu Select Record List in the Floating Menu to enter You will see the recent individual measurement data and you can switch to all Record List from different times by swiping left or right TIME DATE GLUCOSE TIME DATE GLUCOSE 2011 12 20 18 30 97 mg dL 2011 12 20 18 30 97 mg dL 2011 12 21 10 41 124 mg dL i f 2011 12 21 10 41 124 mg dL 2011 12 21 18 16 87 mg dL f 2011 12 21 18 16 87 mg dL f 2011 12 20 19 57 24 mg dL 2011 12 20 19 57 24 mg d
7. L 2011 12 20 21 30 144 mg dL 2011 12 20 21 30 144 mg dL 2011 12 20 23 45 99 mg dL a 2011 12 20 23 45 99 mg dL 2011 12 21 07 04 78 mg dL f 2011 12 21 07 04 78 mg dL s 2011 12 21 09 44 67 mg dL A 2011 12 21 09 44 67 mg dL fe 141 mg dL 141 mg dL 2011 12 21 12 41 29 ms 4 2011 12 21 12 41 297 mga P Settings 2 Click at any data record to find out more information Detailed information will pop up with a semi transparent window Date Sections of testing times W e o TA WA Page Indications 1 Select the Logbook mode from the Floating Menu Select Logbook in the Floating Menu to enter The first page you see is the current 7 days of glucose testing data under the measurement 4 different modes You can swipe to the left to see the previous weekly record or swipe to the right to return to the recent Logbook record 121 23 1 24 1 25 1 27 1 28 1 29 2012 1 16 1 17 1 18 1 19 1 20 1 21 1 22 e3 7 es 2 BOG 96 77 147 163 147 144 132 147 126 117 126 maaa E e 131 71 61 77 ie ae 5 97 112 96 91 97 99 112 96 102 103 98 103 98 xo o Settings Data Plan oil Reviewing Trend Graph my Help Zoom In and Out option for 7 14 30 days view 7 14 30 Day Glucose Test Trend Graphs Pre Meal Post Meal Before Bed Morning 1 Select the Trend Graph mode from the Floating Menu Select Trend Graph in Floating Menu to
8. N The Plan feature is designed to inform the user of their recent self monitoring and self assessing results in average percentage over a period of time It includes Personal Monitoring Diet Exercise and Prescription taken If the user maintains a healthy diet regular exercise routine good medication intake and active blood glucose monitoring then the result will appear as the user has achieved their target goal and have a healthy blood glucose monitoring during this period of time in average percentage NOTE Do not make treatment decisions based solely on the information provided by the iFORA App All health related decisions should be made in conjunction with the advice of a qualified healthcare provider HCP The plan only acts as reference information for the user s own necessity and to acknowledge their monitoring condition over a certain period of time Current Plan EK B Duration period Total overall percentage of personal monitoring achievement during this period Different goals achieved during this period Self monitoring diet exercise prescription achievements during this period fom Settings Current Plan 1 Select Plan on the Main Menu Bar to see your Current Plan If you have already set up a plan before the first page you will see is the total overall percentage of personal monitoring achievement during this period Current Plan fy B 2 You can set up your plan target and d
9. action of glucose with the reagent of the strip The meter measures the current calculates the blood glucose level and displays the result The strength of the current produced by the reaction depends on the amount of glucose in the blood sample Important Information about Performing Control Solution Tests Our Control Solution contains a known amount of glucose that reacts with test strips and is used to ensure your meter and test strips are working together correctly Test strips control solutions or sterile lancets may not be included in the kit please check the contents on your product box They can be purchased separately Please make sure you have those items needed for a blood glucose test beforehand Do a control solution test when e you first receive the meter e at least once a week to routinely check the meter and test strips e you begin using a new vial of test strips e you suspect the meter or test strips are not working properly e your blood glucose test results are not consistent with how you feel or if you think the results are not accurate e practicing the testing process or e you have dropped or think you may have damaged the meter How to Perform a Control Solution Test You will need 1 Meter 2 Test Strip 3 Control Solution Connecting Insert the test strip into the meter ie 0 0 Data 1 Plug in iDiamond Connect iDiamond with iPhone a connecting mess
10. age will appear on the screen and follows by the message insert the test strip into the meter Please follow the instruction and insert the test strip into iDiamond 2 Select the QC option on the screen to mark this test as s control solution test e The meter provides you with five measurement modes each are nls Se gt EHA You can select the required mode by selecting between AM AC PC PM and QC mode When QC is selected the control solution test result will appear on the screen however the meter will not store the test result in the memory of iPhone WARNING When doing the control solution test you have to mark it so that the test result will not be stored in the memory Failure to do so will mix up the blood glucose test results with the control solution test results in memory 3 Apply Control Solution Shake the control solution vial thoroughly before use Squeeze out a drop and wipe it off then squeeze out another drop and place it on the tip of the vial cap Hold the meter to move the absorbent hole of the test strip to touch the drop Once the confirmation window fills completely the meter will begin counting down To avoid contaminating the control solution do not directly apply control solution onto a strip 4 Read and Compare the Result After Processing message appears the control solution test result will then show on the display Compare this result with the rang
11. button on the top right corner to switch between 7 14 30days view To see different times simply slide to the left or right Swipe up to see the next function Pie Chart Low 7 Low 8 Normal 60 Normal 90 33 12 Low 11 Low Normal 84 Normal 48 5 16 m O 0 Data Plan Settings By swiping to the left or right you can switch between the glucose control ratio pie charts of current 7days 14 days and 30 days under 4 measuring modes DATA If using the meter for the first time a message will appear reminding the user to connect the device with the application to start recording You will be limited to see only the reminding message until a test has been taken Reviewing Data Record The meter stores the blood glucose test results along with respective dates and times in memory under iPhone To review the data in the iPhone press Data on the main menu bar next you can select the desired function by tapping the icon on the Floating Menu or alternatively by swiping upwards for different functions Data Record Screen Symbol indication Blood Glucose Test Result Result Blood glucose unit To add notes Help Delete notes Note displays 1 Select the Data Record mode from the Main Menu Bar Select Data in the main menu bar to enter The first reading you see is the last blood glucose result along with the reading date time and the measurement mode An example 199 mg dL 11 1mmol L
12. e is normal 2011 12 25 AM 09 15 Reading in red when glucose is high Note The user can set up the glucose target range in the plan mode according to his her own current status after consulting the doctor to get better control Error Messages customer Err42 Hardware error S V C for Err25 Temperature l is too low Temperature Temperature the meter Err26 lis too high and test strip are in the above Strip has been Strip Rcode is out eah range Strip is Err40 removed during Repeat the measurement test with a Measurement new test blood sample Troubleshooting 1 If the meter does not display a message after inserting a test strip POSSIBLE CAUSE WHAT TO DO Battery of iPhone Recharge the battery of iPhone exhausted Test strip inserted Insert the test strip with contact upside down or bars end first and facing up incompletely Defective meter or Please contact customer services test strips 2 If the test does not start after applying the sample POSSIBLE CAUSE WHAT TO DO Insufficient blood Repeat the test using a new test strip with larger volume of sample blood sample Repeat the test with a new test strip Sample applied Repeat the test with a new test strip after automatic Apply sample only when flashing switch off appears on the display Defective meter Please contact customer services 3 If the control solution testing result is out of range
13. e printed on the test strip vial and it should fall within this range If not please read the instructions again and repeat the control solution test An example 117mg dL 6 5 mmol L 109 165 mg dL 6 1 9 2 mmol L Normal Out of range results If you continue to have test results fall outside the range printed on the test strip vial the meter and strips may not be working properly Do NOT test your blood Contact the local customer service or place of purchase for help NOTE e The control solution range printed on the test strip vial is for control solution use only It is not a recommended range for your blood glucose level e See the Caring for Your iDiamond Meter Set section for important information about your control solutions Important Information about Testing Your Blood Glucose Level WARNING To reduce the chance of infection e Never share a lancet or the lancing device e Always use a new sterile lancet Lancets are for single use only e Avoid getting hand lotion oils dirt or debris in or on the lancets and the lancing device Preparing the Lancing Device for Blood Testing Please follow the instructions in the lancing device insert for collecting a blood sample Preparing the Puncture Site Stimulate blood perfusion by rubbing the puncture site before blood extraction has a significant influence on the glucose value obtained Blood from a site that has not been rubbed exhibi
14. e test strip at a tilted angle When the required amount of blood sample has been absorbed the confirmation window will be filled Do NOT remove your finger until the processing message appears on the screen NOTE e Do not press the punctured site against the test strip or try to smear the blood e If you do not apply any blood samples to the test strip within a period the screen will still keep waiting until any action is taken e The meter will begin to process once the required amount of blood sample has been absorbed If you have not successfully filled the test strip with enough blood samples the system will appear with an error message Please discard the used test strip and retest with a new one NEVER try to add more blood samples to the test strip after the blood absorption process has been completed Discard the used test strip and retest with a new one e f you are experiencing trouble with filling the confirmation window please contact your health care professional or the local customer service for more assistance 5 Read Your Result The result of your blood glucose test will appear after the meter shows the Processing message The blood glucose result will be stored in the memory automatically An example 68 mg dL 3 8 mmol L 2011 12 25 6 Pull out the used test strip Pull out the used test strip Use a sharp bin to dispose of used test strips Always follow the instructions in
15. ents in shock Readings which are lower than actual values may occur for individuals experiencing a hyperglycaemic hyperosmolar state with or without ketosis Please consult the healthcare professional before use e The measurement unit used for indicating the concentration of blood or plasma glucose can either have a weight dimension mg dL or a molarity mmol L The approximate calculation rule for conversion of mg dL in mmol L is mg dL Divided by 18 mmol L mmol L Times 18 mg dL For example 1 120 mg dL 18 6 6 mmol L 2 7 2 mmol L x 18 129 mg dL approximately Intended Use This system is intended for use outside the body in vitro diagnostic use by people with diabetes at home and by health care professionals in clinical setting as an aid to monitoring the effectiveness of diabetes control It is intended to be used for the quantitative measurement of glucose Sugar in fresh whole blood samples from the finger palm forearm upper arm calf and thigh It should not be used for the diagnosis of diabetes or testing on newborns Professionals may test with capillary and venous blood sample home use is limited to capillary whole blood testing Venous blood must be collected only in heparin blood collection tube Test Principle Your system measures the amount of sugar glucose in whole blood The glucose testing is based on the measurement of electrical current generated by the re
16. eric Name Actrapid HM Regular Human Insulin Apidra Insulin Glulisine Humalog Insulin Lispro SETTING Uploading Results onto TeleHealth System Please check with your health provider or insurance company if you are eligible for the TeleHealth program If you are eligible to join the TeleHealth program please follow the instruction below to register your iDiamond to the system 1 Go to your health provider with your iDiamond and iPhone They should assist you to set up your own TeleHealth patient account and to register your iDiamond to the TeleHeaelth system for you 2 Please make sure that the IFORA App under the Setting should have the correct Server URL for the TeleHealth so that the data will be uploaded onto the correct server when you update your data 3 To check if you have successfully completed the registration and set up procedures please carry out a test run WARNING While the meter is uploading data to the TeleHealth it will be unable to perform a blood glucose test Error Messages and Troubleshooting If you follow the recommended action but the problem persists or error messages other than the ones below appear please call your local customer service Do not attempt to repair yourself and never try to disassemble the meter under any circumstances Result Readings WHAT IT MEANS Reading in yellow when glucose is low 2011 12 25 AM 09 15 Reading in green when glucos
17. f blood as it might contain tissue fluid which may affect the test result How to Test Your Blood Glucose Level You will need 1 Meter 2 Test Strip 3 Lancing Device 4 Lancet Connecting Insert the test strip into the meter Jata Plan FAQ s 1 Insert the test strip in to the meter Connect iDiamond with iPhone a connecting message will appear on the screen and follows by the message insert the test strip into the meter Please follow the instruction and insert the test strip into iDiamond 2 Select the appropriate measuring mode by touching the screen The meter provides you with five measurement modes each are A ales See a E E before meal about 2 hours after a meal wake up in the morning mam inthe late evening or before going to bed testing with the control solution V Correct X Incorrect 3 Obtaining a blood sample Use the pre set lancing device to puncture the desired site Wipe off the first appeared drop of blood with a clean cotton swab The size of the drop should be at least as actual size of the blood drop 0 5 uL which is 0 5 microliter uL of volume After penetration discard the first drop of blood with a clean cotton swab Gently squeeze the punctured area to obtain another drop of blood Be careful NOT to smear the blood sample 4 Apply the sample Gently apply the drop of blood to the absorbent hole of th
18. he control solution vial and discard the remaining solution after 3 months e It is recommended that the control solution test be done at room temperature 20 C to 25 C 68 F to77 F Make sure your control solution meter and test strips are at this specified temperature range before testing e Shake the vial before use discard the first drop of control solution and wipe off the dispenser tip to ensure a pure sample and an accurate result e Store the control solution tightly closed at temperatures between 2 C to 30 C 36 F to 86 F Do NOT freeze iDiamond Meter Specifications Model No DM40 Dimension amp Weight 55 L x 36 W x 12 10 H mm 13 6 g Power Source iPhone Memory Control by iPhone External output Apple 30 pins Connector Auto electrode insertion detection Auto sample loading detection Auto reaction time count down Auto switch off after 3 minutes without action Temperature Warning Operating Condition 10 C to 40 C 50 F to 104 F below 85 R H non condensing Storage Transportation Conditions 20 C to 60 C 4 F to 140 F below 95 R H Measurement Units Control by iPhone Measurement Range 20 to 600mg dL 1 1 to 33 3mmol L This device has been tested to meet the electrical and safety requirements of IEC EN 61010 1 IEC EN 61010 2 101 EN 61326 1 IEC EN 61326 2 6 z a ewen first opening a ee Panes documents
19. iDiamond Blood Glucose Monitoring System Owner s Manual Version 1 0 2012 04 Dear iDiamond System Owner Thank you for purchasing the iDiamond Blood Glucose Monitoring System This manual provides important information to help you to use the system properly Before using this product please read the following contents thoroughly and carefully Regular monitoring of your blood glucose levels can help you and your doctor gain better control of your diabetes Due to its compact size and easy operation you can use the iDiamond Blood Glucose Monitoring System to easily monitor your blood glucose levels by yourself anywhere any time If you have other questions regarding this product please contact the place of purchase or call the Customer Care Line IMPORTANT SAFETY PRECAUTIONS READ BEFORE USE 1 Use this device ONLY for the intended use described in this manual 2 Do NOT use accessories which are not specified by the manufacturer 3 Do NOT use the device if it is not working properly or if it is damaged 4 Do NOT use the equipment in places where aerosol sprays are being used or where oxygen is being administered 5 Do NOT under any circumstances use the device on newborns or infants 6 This device does NOT serve as a cure for any symptoms or diseases The data measured is for reference only 7 Before using this device to test blood glucose read all instructions thoroughly and practice the test Carry
20. out all the quality control checks as directed 8 Keep the device and testing equipment away from young children Small items such as the battery cover batteries test strips lancets and vial caps are choking hazards 9 Use of this instrument in a dry environment especially if synthetic material are present synthetic clothing carpets etc may cause damaging static discharges that may cause erroneous results 10 Do NOT use this instrument in close proximity to sources of strong electromagnetic radiation as these may interfere with the accurate operation KEEP THESE INSTRUCTIONS INA SAFE PLACE Contents 1 Getting Started e About the iDiamond Blood Glucose Monitoring System e Test Strip e How to Install and Update the iDiamond Diabetes Manger App e Important Health related Information e Intended Use e Test Principle 2 Important Information About Performing Control Solution Tests e How to Perform a Control Solution Test 3 Important Information About Testing Your Blood Glucose Level e How to Test Your Blood Glucose Level 4 Obtaining a Blood Sample From Alternative Sites 5 Viewing Test Results on the iPhone e DATA gt Reviewing Data Record gt Reviewing Record List gt Reviewing Logbook gt Reviewing Trend Graph gt Reviewing Target Pie Charts e PLAN gt Current Plan gt Diary Management e FAQ gt Medicine Diabetes 101 and Tutorial e SETTING gt Uploading Results onto TeleHealth System Error Messages
21. the lancing device insert when removing the lancet WARNING The used lancet and test strip may be bio hazardous Please discard them carefully according to your local regulations Obtaining a Blood Sample from Alternative Sites You can test on a variety of locations on your body Important There are limitations with AST Alternative Site Testing Please consult your health care professional before you perform AST Alternative Site Testing AST AST function can provide you to test the blood glucose other than the fingertips When to use AST Food medication illness stress and exercise can affect blood glucose levels Capillary blood at the fingertip reflects these changes faster than capillary blood at other sites Thus when testing blood glucose during or immediately after a meal physical exercise or any other event take a blood sample from your finger only We strongly recommend that you perform AST ONLY at the following times e In a pre meal or fasting state more than 2 hours since the last meal e Two hours or more after taking insulin e Two hours or more after exercise Do NOT use AST if e You think your blood glucose is low e You are unaware of hypoglycemia e You are testing for hyperglycemia e Your AST results do not match the way you feel e Your routine glucose results often fluctuate Viewing Past Test Results on iPhone Data Navigation Guide Navigate between different f
22. ts a measurably different glucose concentration than blood from the finger When the puncture site was rubbed prior to blood extraction the difference was significantly reduced Please follow the suggestions below before obtaining a drop of blood e Wash and dry your hands before starting e Select the puncture site either at fingertips or another body parts please see section Obtaining a Blood Sample from Alternative Sites AST on how to select the appropriate sites e Clean the puncture site using cotton moistened with 70 alcohol and let it air dry e Rub the puncture site for about 20 seconds before penetration e Use a clear cap included in the kit while setting up the lancing device Fingertip testing Press the lancing device s tip firmly against the lower side of your fingertip Press the release button to prick your finger then a click indicates that the puncture is complete Blood from sites other than the fingertip Replace the lancing device cap with the clear cap for AST Pull the cocking control back until it clicks When lancing the forearm upper arm hand thigh or calf avoid lancing the areas with obvious veins because of excessive bleeding NOTE e Choose a different spot each time you test Repeated punctures at the same spot may cause soreness and calluses e Please consult your health care professional before you begin AST e t is recommended that you discard the first drop o
23. unctions simply by selecting the desired function from the Floating Menu lS Ate fatty food El Siow o Ie T heavy exercise By selecting different functions on the Floating F l Menu you can navigate Too much insulin between them much efficiently amp _ Too much insulin co Mr BEC io fo to 2 a Data Navigation Guide Motion Navigate between different functions simply by swiping up down left and right 2011 12 25 AM 09 15 68 Data Record by swiping left or right of the data you can switch between current and previous data Swipe up to see the next function Record List TIME DATE ote 2011 12 20 18 30 97 mg dL 2011 12 21 10 41 124 mg dL 2011 12 21 18 16 87 mg dL 2011 12 20 19 57 24 mg dL 2011 12 20 21 30 2011 12 20 23 45 2011 12 21 07 04 2011 12 21 12 41 Record List by swiping left or right of the log you can switch between all the data recorded from different times Swipe up to see the next function Logbook 1 16 1 17 1 18 1 19 1 20 1 21 1 22 Caer CICALA cmc m Ea 132 147 126 117 126 137 113 117 PC a 121 127 p cee 71 61 B o pe De ar ey os Logbook by swiping left or right of the log you can switch between current 7 days of glucose testing data to the previous weekly log records Swipe up to see the next function Trend Graph 30 Days Trend Graph select the enlarge
24. uration period when you first enter the Plan Mode The setting page will appear when you first enter the Plan Mode You can set up your desired period and glucose target after consulting your doctor Set New Plan Duration Jun 13 2012 Jun 19 2012 7 Days 14Days 30 Days Goal 120 mg dL 120 mg dL 120 mg dL 120 mg dL Cancel 3 If you have historical plan but have not set up a new current plan You will see the Plan List and a dialogue window to remind you to set up a new current plan If select yes you will be direct to set up a new current plan if select no exit the dialogue window and return to the Plan List Plan List Diary Management To manage your self monitoring progress by selecting the three options diet exercise and prescription to examine whether those daily action can achieve your goal to control glucose i a P FAQ Medicine Diabetes 101 and Tutorial ae Medicine Diabetes 101 gt Tutorial 1 Select the FAQ mode from the Main Menu Bar Select FAQ in the Main Menu Bar to enter and then the Sub Menu will appear You will see the information categorized into different sections such as medicine diabetes 101 and tutorial If you wish to find the specific information much quicker you can also search by typing key words in the search bar on the top of each section page t Medicine Oral Drugs Non insulin Injection Insulin Brand Name Gen