1. USER MANUAL SR H320 1 Welcome screen Open the equipment total power switch the screen displays a welcome interface as shown in picture 1 thermage pic 1 2 Enter the system 1 Press the upper left corner of the button into the main system interface as shown in picture 2 READY FOR TREATMENT 2 0 0 Average level 4 0 Maximum level 8 5 Treatment time 0 20 hr min Tip in use Eyes Tip 3 0 Delivered 10 Avg J cm pic 2 2 Press the start button again which on the left upper of the panel interface jump as shown in picture 3 The user can choose to press the energy adjustment buttons again on the right side of interface to set the treatment time The system default treatment time for 40 min the highest treatment time can be set up for 60 min Each time you press the button increasing time at 5 minutes intervals such as 5 10 15 READY FOR TREATMENT 208 Treatment Average level 4 0 Maximum level 8 5 time can be Treatment time 0 20 hr min set Tip in use Eyes Tip 3 0 Energy level Delivered O es 100 Energy delivered Energy per unit Avg J cm area pic 3 Treatment time show the current treatment duration and time can be set Energy Level Shows energy output level of present treatment head maximum is 10 and minimum is 0 5 If you rotate the rotary button clockwise 0 5 level increase If you rotate anticlockwise 0 5 level reduce Ene
2. rgy Delivered Shows the present output energy When you adjust the energy level energy changed When energy level is 0 5 energy output is 2 6 When energy level is 10 energy output is 52 Avg Energy Shows the avg Energy of present treatment head When you adjust energy level avg energy chaged The following table shows the ere of level delivered and avg ims est 3 push the device on the upper left corner of the start again interface jump as shown in figure 4 READY FOR TREATMENT ae Average level 4 0 Maximum level 8 5 Treatment time 0 20 hr min Tip in use Eyes Tip 3 0 Handle to the output energy at this time press N O ey Can reduce the energy output press M O S Can increase energy output 3 The alarm unit When equipment is started if the handle is not installed on the treatment the red light flashing on the device and a di di di sound the alarm install treatment head at this time cancel the alarm
Download Pdf Manuals
Related Search
Related Contents
CG029 _ Les accessoires en oxygénothérapie Descargar NA221TRB 製品保証書 MYLAPS Onboard Display 2G Driver ID Digitus 7.1 PCI Sound Card Little Disk UI 400-800 Datasheet fruits et arboriculture fruitiere - Home Gigabyte N260OC-896I NVIDIA GeForce GTX 260 graphics card Copyright © All rights reserved.
Failed to retrieve file