Home

Installing CLIO under Windows

image

Contents

1. followed by Ok Don tforget d itis essential to create the directories structure If you are upgrading a Lite version type lite instead of 12345678 Run Ei ES Type che name of a procram folder document o Interet 3 resouce and Windows will open it for you Oper cchot0 1 2345676 exe d Z Cancel Browse Toupgrade an existing installation 1 Copy the file in the C CLIO40 directory 2 Take note of the following CLIO settings see 7 3 and 7 4 Microphone sensitivity Printer Palette Amplifier amp SwitchBox TTLcontrol 3 Delete the file clio stp in the C CLIO40 directory 4 Click on the Start button choose the Run option and type c clio40 12345678 exe d followed by Ok Don tforget d itis essential to create the directories structure If you are upgrading a Lite version type lite instead of 12345678 5 Afterrunning the new software reenter the settings previously saved 10 Installing CLIO
2. CLIO Software release 4 5 and above under the various Windows environments Itcovers also troubleshooting when the system is run under Windows orin MS DOS mode As last topic itcovers the software upgrade from one version to a newer one From here on the CLIO PC board and Software are also referred as the CLIO system or simply CLIO Allreferences are given with respect to CLIO User s Manual as anexample refer to 1 3 means refer to chapter 1 paragraph 1 3 of CLIO User s Manual 2 Windows compatibility The CLIO system is compatible with all Windows versions except Windows 3 1 Window NT and its successor Windows 2000 So you will be able to install CLIO under the following Operating Systems OS 1 Windows 95 2 Windows 95 OSR2 OEM Service Release 2 3 Windows 98 4 Windows 98 SE Second Edition 5 Windows ME Millennium Edition The procedures described in this documentrefer directly and are described with examples and figures to the Windows 98 SE operating system English version they can be applied with only minor modifications and appropriate translations to all the other OS and languages Installing CLIO 1 3 Nature of the CLIO system CLIO isan ISA legacy and MS DOS native hardware software system From an hardware point of view this means 1 CLIO needs to operate to be phisically installed in a 100 compliant ISA slot 2 Provided an ISA equipped computer CLIO can operate with any kind of p
3. Installing upgrading and troubleshooting your CLIO system under the Windows environment Audiomatica Srl Rev 1 1 June 2001 Contents 1 What does this document cover cccceeeseeseeneeeenseeecenseeeenseecenseeeenseesonseenseneesooaes 1 2 WINQOWS COMDAUUDINNY scicesciecseseectcetseaseesctetastecsenetacennstecuvacsseneencese vecsvenciecueecsentebesecenteeet 1 3 Nature Of the CLIO system eicesese ein ttie ens edacestsseremettorssetaveonsudsumensseuavinusenteresoetssegesuteiwesies 2 4 Installation Procedure sipiccostiectespeaescstesrencerssnnenssairesedsneonatensvecneamneuentiareervoesterrianomance ts 2 5 Running CLIO for the first time ccccceesseeseeeseeeseenseeeeesseeseenseeseeesseeseenseeseenseeesoenaes 4 6 Troubleshooting your CLIO installation cccccessesseeeseesseeeenseeeeeenseeseenseessoenseesees 5 6 1 The program doesn t start and says There is not enough memory 5 6 2 CLIO doesn t work What should do now A simple test cccssssssseeeseeesenees 5 6 3 Hardware requirements and possible conflicts ccesscceeseeeeseeeeseecenseeeeneseees 6 6 4 What s next Windows hardware settings report ccssscccesseeceeseesnseeseeneeseees 8 7 Upgrading the CLIO software ccccsssssseeeeceeeseeeeeeeeseeeeeeseensseeeseoassseeeseeensseessooes 10 1 What does this document cover This document covers the installation of the CLIO HR 2000 PC board and of the
4. L Document 5 0 Haj Raccoglitore Office Ea Microzott Data Link a Database di Microsoft Access 7 Altri documenti Office Follow the wizard click on Browse and open the CLIO executable inside the CLIO40 folder xi Lookin cio E c File name clio Files of type Programs Cancel A 5 Running CLIO for the first time Just double click on the newly created icon A new full screen window should open and you are ready to work with CLIO Remember that you are running a DOS application under Windows to switch between CLIO and other running tasks simply press Alt Tab to get back to CLIO click on the CLIO icon on the Application Bar Youarenowready totestyourinstallation with some simple measurements and calibrations please connect Output A with Input A with the pin to pin cable now follow the procedure in 3 4 please execute any single step as described if you fail to obtain the result expected do not go further but pass to the next paragraph to troubleshoot your installation If youcomplete the procedure OK your CLIO system is running fine and you can startimmediately working and taking measurements with it thus skipping the next sections good work As last advice if you are using one of Audiomatica s microphones MIC 01 or MIC 02 remember that you can connect them directly to CLIO s input but you also need to power them switching the phantom power supply on to do this see 8 1 5 or simply pre
5. ce Manager tab CDROM Disk drives aa Display adapters eo Floppy disk controllers H 4 Hard disk controllers rae Keyboard rl Modem ce Mortars rl Mouse B Network adapters cl Ports COM amp LPT E SCSI controllers E Sound video and game controllers c al System devices 8 Installing CLIO 3 Double click on Computer The computer properties dialog box appears Select Direct Memory Access DMA Computer Properties ki View Flesources Reserve Resources Interrupt request RO 0 Direct memory access DMA C input output 1 0 C Memory Standard Floppy Disk Controller MS Windows Sound System Compatible Direct memory access controller Cancel 4 Select Input Output 1 0 Scroll down until you visualize the I O region around 0300 Computer Properties F View Flesources Reserve Resources nteruptrequest IRQ Direct memory access DMA input output VO Memory Hardware using the setting a Sef 0210 0211F 3Com EtherLink Il 154 3C509b Combo in PrP rode 1 0220 0224F Windows Sound System Sound Blaster E mulation Oe 4 0277 0 read data port for 154 Plug and Play enumerator hi U2Fe O2FF Communications Port COM 20376 0376 Intel 82371FB PCI Bus Master IDE Controller 3 0376 0376 Secondary IDE controller dual fifo ay 0378 037A ECP Printer Port LPT1 1 cea ea oe fm 1m 1 fami wit ail Windowsis gently showing you which peripheral or card
6. hardware requirement memory hard disk processor speed 1s stringentif Windows is used different limitations apply if an MS DOS based system 1s used refer to CLIO User s Manual for details DMA Channel 3 is needed to operate CLIO s generator If the generator doen s work itis very likely that there is ahardware conflict with this resource The I O address range is needed to operate CLIO s analyzer and to control all the hardware settings NOTE The exclusiveusage of DMA channels may create unresolvable conflicts with other hardware CLIO may be operated with limited functionality without the need for DMA channel number 1 in this situation you are not able to use the Leq Measurement Menu see 14 4 all other functions should operate normally Fulfil these hardware requirements may not be an easy task especially if other espansion cards are present in your computer The causes of conflict may be divided in two main categories peripherals integrated on your main PC board or add on cards inserted in your mainboard s ISA expansion slots Itis very unlikely thata PCI expansion cardis conflicting with CLIO To troubleshoot your installation you need to locate the conflicting hardware and either reconfigure disable orremove it The on board conflicting integrated peripherals may be 1 Parallel ports configured in ECP mode 6 Installing CLIO 2 Infrared serial ports 3 Audio subsystems Tocheckif any on board peripheral is conflicting y
7. here are too many running residents and you need to modify the autoexec and config files to remove or disable part of them We suggest the following procedure 1 Since CLIO doesn t need any system service apart from the keyboard driver it is possible to try for testing purposes to completely remove the two files Either rename the autoexec bat and config sys files or move them away from the system root 2 Re bootstrap your computer 3 Verify that CLIO is nowrunning 4 Create two new autoexec bat and config sys files with minimal configuration we suggest to activate only the keyboard driver if you are notusing the US keyboard otherwise we suggest to work without those files 6 2 CLIO doesn t work What should I do now A simple test In order to troubleshoot your CLIO installation please get the following 1 aloudspeaker system ora single driver a midrange is the best choice 2 apin to alligators connecting cable tip to red alligator and shield to black one Until now we have left Input A connected to Output A this is why if CLIO works correctly itis possible to letit self test all its functions and execute all the calibrations without the need for external devices support Installing CLIO 5 during the procedure described in 3 4 you are actually testing two things the capability of generating asignal through CLIO s output and the capability of acquiring and analyzing it through CLIO s input If something goes w
8. is using the resources that CLIO needs In the case showed we found a MS Sound System card conflicting with DMA 3 and no hardware at I O 0300 Installing CLIO 7 Upgrading the CLIO software You should have received either via snail mail or e mail the sofware upgrade to the latest software release In the first case you received a diskette labelled CLIO Program Disk To install the software upgrade 1 Take note of the following CLIO settings see 7 3 and 7 4 Microphone sensitivity Printer Palette Amplifier amp SwitchBox TTLcontrol 2 Delete the file clio stp in the C CLIO40 directory 3 Follow the procedure given in section 4 4 Afterrunning the new software reenter the settings previously saved Inthe second case you received a file from Audiomatica If you received Lite software version upgrade the file is named lite exe if you received a standard or QC version upgrade then the file is 12345678 exe where 12345678 is your CLIO system serial number This file is useful for upgrading an existing installation without loss of the user s data directories or for creating aclean install from sctratch in the case you are reinstalling the software after an hard disk formatting To install the software from scratch 1 Create the C CLIO40 directory you may use also another name if you prefer 2 Copy the file init 3 Click on the Start button choose the Run option and type c clio40 12345678 exe d
9. n cable to make the proper connections as described later Switch on the computer and wait until Windows has started Insert the diskette labelled CLIO Program Disk inthe floppy drive Click on the Start button choose the Run option and type a install followed by Ok Run Ei Ei Typeche name of a procram folder document o Interet resouce and Windows will open it for you Log OFF Interet Operr ainstall Cancel Browse Shut Down A DOS window should pop up press Enter to confirm the software installation When the installation finishes close the DOS window 2 Installing CLIO 2 INSTALL Auto a ii PREPARING TO COPY INSTALLATION FILES Miei E FROM DRIVE A TO DRIVE C Fress any key to continue or Ctrl c to abort The software should install smoothly into the C CLIO40 folder automatically created The following folders structure is created after software installation H cliog0 dr data We will now create a shortcut on the Windows desktop in order to run CLIO click with the right mouse button on your desktop choose New and then Shortcut Active Desktop Arrange Icons Line Up Icons Refresh Paste Paste Shortcut Properties Installing CLIO I LJ Folder Test Document wr Documento Microsoft word a Bitmap Ima ge a Wave Sound 5 Briefcase Fresentazione di PowerPoint 5s Foglio di lavoro Microsoft Excel E Microgott HTM
10. ou have to access your PC s BIOS settings This is usually accomplished pressing a particular key or sequence of keys while your PC is booting any PC is telling the user whichis the correct key to press to enter BIOS the most commonis the Del key but you may need to press F or a different one When inside BIOS you should locate a menu like INTEGRATED PERIPHERALS inside which there are listed the peripherals present and their settings The conflicting ISA add on cards may be 1 Sound cards 2 Network cards 3 Expansion parallel ports 4 SCSI controllers The main difference with the preceeding case when an on board peripheral was conflicting is that an expansion card may be for testing purposes physically removed This is a quick way for isolating the cause of problems and assessing CLIO s functionality In our experience the vast majority of conflicts are generated by 1 On board parallel ports configured in ECP mode using DMA channel 3 2 ISA sound cards or on board audio subsystems using DMA channel 3 3 ISA network cards using I O address 300 Installing CLIO 7 6 4 What s next Windows hardware settings report Windows can give you an easy way to isolate the conflicting hardware Follow this procedure 1 Click with the right mouse button on the My Computer icon on the Windows desktop Then click Properties hy Computer My Documen Internet _ Explorer Properties 2 Select the Devi
11. rocessor no matter how fast ornew this processoris ISA compatibility whichis a wellrecognized industry standard guarantees CLIO s functionality 3 As the word legacy implies and as itis needed with all other ISA devices the installation in a Windows environment will go through some manual actions and man to machine interactions atleast for changing the on board jumper and when needed for inspecting and modifing the computer BIOS settings It is not possible to have a 100 automatic and hassle free installation since Windowsis notable to modify these settings From a software point of view this means 1 CLIO can exploit 100 of what is described in its users manual only under the MS DOS environment 2 When run under Windows CLIO as all DOS applications benefits of several services which compensates the minimal lacks encountered and greatly enhance the overall user s satisfaction and productivity this is why we strongly encourage you to run CLIO under a Windows normal session notin the exclusive MS DOS mode when the OS exploits its full multitasking power Leave MS DOS and Windows exclusive MS DOS sessions only for testing and other particular purposes like production line quality control management in these cases itmay be advisable to have the PC completely devoted to CLIO 4 Installation Procedure To install the CLIO card into your PC follow the procedure given in 3 2 Before proceeding further have ready one pin to pi
12. rong we have to open the loop and separately test the two hardware sections The first thing to test is CLIO s generator To dothis disconnect the pin to pin cable and connect the loudspeaker to Output A with the pin to alligators cable noexternal amplifieris required Now let s repeat the first part of the procedure in 3 4 press F4 to recall the Generator amp Level Meter and then S type 1000 in the Freq field leaving the other fields at zero press Enter Youshouldheara 1kHz sinusoid listen carefully CLIO is ahigh precision signal generator the sinusoid has to be continuous without clicks pops or any other disturbing effect it has to be clean and crisp without any audible distortion ithas to be stable without any frequency shift effect The ability of generating is vital for CLIO and let it also test and calibrate its input so if you are encountering problems here itis crucial that you solve the hardware software conflicts that are causing them read the following sections and get back to the sinusoid test until itruns fine Only then you can repeat the procedure in 3 4 to finalize CLIO s installation 6 3 Hardware requirements and possible conflicts The CLIO systems needs the following PC system resources 1 The exclusive usage of DMA channels number 1 and 3 2 A free I O Address range selectable between the two possible 300 HEX using 300 304 range or 310 HEX using 310 314 range No IRQ 1s needed No other
13. ss F4 and then H 4 Installing CLIO 6 Troubleshooting your CLIO installation 6 1 The program doesn t start and says There is not enough memory HARNING There is not enough memory In this case CLIO cannot find enough DOS conventional memory to run Pay attention DOS memory is not the system memory usually Windows machines have from 8MB to 128MB and more but is that particular space 640kB within the system memory used to emulate DOS and thatis common to all DOS applications Depending on the number of DOS resident programs that are launched when any DOS session is invoked each DOS application will have a variable amount of memory available within the 640kB maximum size CLIO needs at least 585KB free to run To inspect the available amount of memory type MEM from MS DOS Prompt Look at the report the Largest executable program size is the memory free for any DOS application To go into deeper detail type MEM C you ll get areport with also a list of the running residents DOS memory is configured at start up by two standard files autoexec bat and config sys These files reside in the system root usually C It is far beyond the scope of this paper to describe how DOS configures the system at start up you need to understand that these files contain a list of the programs invoked at start up and thatremain resident under all DOS running applications If you get the above error messageit means that t

Download Pdf Manuals

image

Related Search

Related Contents

dds d étergent d ésinfectant s urodorant  Instructions for use - Orthomedica  010609 Zeitschaltuhr DT CH  User`s Guide  Garagentoröffner Modell MotorLift 1000 Instructions  1 - Sears  EndoFast Reliant™ System Instructions For Use  I/O Modules, I/O Expander and I/O Concentrator  濁度・色度計 WA-PT  Séance du 27 mai 2014 Le Conseil communautaire, légalement  