1. AOL Mail HW Virtu g Jasc Pai meg UPStart Es S OY 2 05PM Now you can start using Upstart as normal To use Upstart and the RUC over the Internet make these changes On the VSP screen where you entered in the LAN IP address enter in the WAN IP address of the location where the RUC is located that you want to connect to That address might be something like 24 8 xxx xxx To get this address you can go to www ipchicken com or similar website Now assuming this location has a router installed you will need to open a port in your router to route port 9761 to the RUC Typically this will be called Port Forwarding in the router If you don t already have port 80 opened you can forward this port to the RUC also so that you can remotely access it s webpages Refer to your router manual for instructions on how to open the firewall port Other Features Please see the User s Manual for details on how to use the other features of the RUC such as DYNDNS The current User s Manual can be found at http www webmtn com RUC RUC User s Guide pdf Recognize that this manual is a work in progress so there will be constant changes and updates to it Confidential amp Proprietary to Web Mountain Technologies not to be disclosed 8 Using Trigger Events A couple of quick comments about using the UPB Trigger webpage The intention of the UPB Trigger page is that when the RUC sees a UPB signal on the powerline
2. Mountain Technologies not to be disclosed 5 HW Virtual Serial Port HW VSP3 Admi J UDP Search Virtual Serial Port Settings Advanced General ih i foie u ExtemalN Port 2003 YSP LAN Status Created Status Baud Bits Counters Parity VSP LAN QUEUE Stopbits Re 0 0 0 Handflow Tx 0 0 0 Version 3 1 0 I O Serial over IP Multiport driver Now open Upstart Upstart will probably give you an error message that it can t communicate with the PIM Click out of these pop ups and get to the main screen of Upstart Click on Tools UPB Interface Device Select You will see this screen Set the type of PIM to Powerline Interface Module then select the COM port to be the COM port you selected above in HW VSP Upstart should show it to you in the list of available serial ports Then click on CONNECT Confidential amp Proprietary to Web Mountain Technologies not to be disclosed 6 Fie View Network Doce Links Toots Help Sasee PPLADES BIERHBABYALB atexe 20 Roo S Den OH Fonli 4 OH Lig j BO bose Crewe E Froe Pored E E D hose hauss bobbesoor babbis Ikoron 00 tepoto fonighe i Anm E aieiaa teno F wegg weg Une ond wega 4 wega I I I I I D gt uemo i I I I I I Une ots E uname 4 ueo Une O12 i veon i 4 uos 1 Get breo venion Get
3. items Now double click on Updater_Starter exe to run the program This window will pop up In most cases you can accept the defaults however if you have changed any of these parameters you will need to update them in the screen Click OK Now the application will start and first connect to the RUC You will see this screen Confidential amp Proprietary to Web Mountain Technologies not to be disclosed 10 m C Windows system32 cmd exe e ae ele lB x Target address WHTRUC LIA ID B4cCB IP address 192 168 1 73 LIA Status 0000 Control PDU Seq 0 Data PDU Seq 00 m LIA ID B4cB IP address 192 168 1 73 LIA Status 4000 in loader mode Control PDU Seq 1 Data PDU Seq 00 Programming from Ruc_Updater cry Sending part 1 Configure LIA B4CB J Modify IP Address Capture Target Locate LIA Reset LIA Notice that it says Programming from Ruc_Updater cry The unit has connected and is now programming Also see the very last line This gives you an indication that the programming is occurring Here is an updated screenshot showing progress Confidential amp Proprietary to Web Mountain Technologies not to be disclosed 11 Erase Erase Data Erase Program Program a Programming from Ruc_Updater cry Sending part 1 Sending part Sending part Sending part Sending part Sending part Sending part Sending part Sending
4. statup command rece Get poyda Get UPO Optere Feet IPS Yassine Irk Orkra Node Seiected poradna r aiece cpetcral aK _ cere Units Unit O12 Den OH Lights Master chan If Upstart connects to the PIM correctly you will see blue checkmarks on the left and a message that says Selected Powerline Interface is Operational Confidential amp Proprietary to Web Mountain Technologies not to be disclosed ed UPStart testCEDIA upb CEDIA il le Netwe l i a w co See E a a N E ETS amp amp All Devices Rooms EE New Room Na El Sbutton 0 Select Interface Powerline Interface Module w Communications Port Comm 10 Settings Diagnostics Find the UPB Interface port 4 Unit 004 4 Unit 005 4 Unit 006 Linkoo2 4 Unit 001 1 4 Unit 002 1 4 Unit 004 Unit 005 4 Unit 006 1 f Linkoo3 4 Unit 001 i 4 Unit 005 Link025 Unit 001 1 P Unit 001 1 Linko26 P Unit 007 1 Unit oo 1 Fi Linko23 Unit oo 1 4 Unit 001 1 Gb Link033 P Unit 001 1 P Unit oo 1 an Link036 s w Test Data R Get UPB Options Remote UPB Controller RUC V Get UPB Version 3 Pf Get noise level 3 J Get manufacturer lt Info Selected powerline interface is operational OK Cancel si All Devices Signal To Online r Tx 1 NUM fw 2010 Ty RUC Use O imnbox
5. Quick Start Guide RUC Remote UPB Controller Web Mountain Technologies Updated 1 4 2011 This document is intended to be used to allow a user to setup their newly acquired RUC unit and quickly start using it If more details are needed please refer to the full User s Manual located on the Web Mountain website at http www webmtn com RUC RUC information php Basic Setup There s not much to this Follow these steps 1 Remove the RUC from its shipping container 2 Remove the SPIM from its shipping container and using the supplied cord connect the SPIM to the COM1 DB9 on the RUC Plug the SPIM into a power outlet 3 Connect an Ethernet patch cord from the Ethernet RJ45 jack on the RUC to your local Ethernet switch router 4 Take the included power supply plug its cord into the power jack on the RUC then plug the power supply into a power outlet 5 On the end of the RUC where the Ethernet patch cord plugs in you will see the LED closest to SW2 start blinking on about a 1 second interval You will also see the Ethernet LEDs on the RUC blink to indicate activity and the port on the switch router where the RUC is connected will show connection and activity with its LEDs Accessing the webserver of the test RUC This is pretty easy We will ship the RUC in its default mode of being a DHCP client We re assuming that your LAN has a DHCP server on it and the RUC will get an address from this DHCP server To access the R
6. UC s webserver merely enter this address into your browser http wmtruc You might need to wait 5 minutes or so after powering up the RUC for the RUC s host name to be recognized by your network Once you try to access this website you will be challenged for a user name and password There are two logins you can use First anormal user The user name is wmtruc and the password is password Or second the administrative user The user name is admin and the password is broncos If you log in as the normal user you shouldn t be able to access the Admin webpage Feel free to change the passwords if you wish To login as the Admin user you will first need to close out of your browser and come back in Once you get in you will see these pages o Home o Networking Configuration Confidential amp Proprietary to Web Mountain Technologies not to be disclosed 1 Device Configuration Admin UPB Transmission Use to send a UPB signal Dynamic DNS UPB Receive UPB Trigger Control Panel o00000dCO NOTE Before proceeding to setup your RUC it is highly recommended that you determine if there is a firmware update available for your RUC To check this look at the Home page in your browser and notice the firmware revision It will appear something like 2 00 23 The last two digits are the important distinction Now go to http www webmtn com RUC RUC information php and look at the firmware download section towards the
7. bottom of this page The file name will include something like V23 in it If this number is higher than the number on your Homepage we recommend updating your firmware To update your firmware please refer to the procedure shown later in this document Upstart over the LAN Internet One of the main purposes of the RUC is to basically create an Ethernet PIM Now you can locate the PIM anywhere you want to on your LAN or even on the Internet and use it to run Upstart over a network rather than being constrained to the physical location where the PC is located This is one of the main features we want you to test out CAUTION It should be noted that UPStart operation over a network may not be quite as robust as on a hard wired PIM If you are having problems a retry or two of the test you are trying to run should get you accurate results It is strongly encouraged that the user configure Upstart slightly differently than normal select Ask if verify should be performed or Never perform verify at startup on the UPStart File options tab rather than Always perform verify at startup It is also strongly suggested that the user do individual device verifies rather than network verifies whenever possible Smaller chunks of testing will perform better than larger chunks especially in the situation where there is some congestion on the network Introduction to Upstart In case you are not familiar with the UPB setup and programmin
8. g tool Upstart Upstart is a Windows based program that is used to setup your initial UPB network then program and add devices to that network In order to use Upstart you must connect a serial or USB PIM PC Interface Module to the PC running Upstart This PIM must be plugged into a power outlet so that it can be used to transmit and receive signals from the PC to and from the powerline network UPB is a powerline home automation protocol Signals are sent over the powerline to control lights and appliances However the devices that are used to control these lights and appliances must be programmed to behave in the fashion you desire That s the purpose of Upstart In addition Upstart provides some of the best if not the best diagnostic tools as compared to other home automation technologies Confidential amp Proprietary to Web Mountain Technologies not to be disclosed 2 The most common way of using Upstart is with a local PC connected to either a serial or USB PIM which is plugged into an outlet in the house In many cases this is inconvenient in that the location where you are plugged in with the PIM in order to program devices might not be the final location or the best location for the PIM in terms of signal strength and if you are programming a large number of units you are constantly moving your laptop causing you to constantly reconnect to the PIM thereby dramatically reducing your productivity The RUC unit u
9. have all of the necessary software components let s get the hardware connected If you haven t already connected a SPIM take your WMT SPIM 0O1 and connect the supplied serial cable to the DB9 connector on the bottom of the unit Then take the other end of the serial cable and connect it to the DB9 connector on the RUC unit labeled COM1 Running Remote Upstart Now double click on the icon on your desktop for HW VSP It will bring up a pop up window that looks like this Confidential amp Proprietary to Web Mountain Technologies not to be disclosed 3 HW Virtual Serial Port HW VSP3 Admi E O X UDP Search Virtual Serial Port Settings Advanced Warning UDP SEARCH works only with original HW group devices on local network segment No device found MAC Address IP Address Device T HUS rou E Ez Version 3 1 0 VO Serial over IP Multiport driver Click on the tab marked Settings and make this page look like this MAKE SURE NVT Enabled is not checked HW Virtual Serial Port HW VSP3 Admi XK UDP Search Virtual Serial Port Settings Advanced Settings V Log Enabled F Create VSP Port when HW YSP Start up M TCP Server Mode I Purge Buffers when Port is Opened I Connect to Device even if Virtual COM is closed J Use NOP to Keep Connection J Renew Automatically M NYT Enabled l Remote Port Setup Keep Connection Strict Baudrate Emulation I Clo
10. it will monitor that signal and compare it against its database and take an action based upon its programming For example we could program the unit such that when it recognizes Activate Link 21 it should wait 5 seconds and then send a Deactivate Link 21 Or when it sees Deactivate Link 32 it will send an email to you indicating the garage door has been closed The top part of the Trigger Event screen defines what the trigger UPB signal is while the bottom half indicates what should happen upon receipt of that trigger i e send another UPB signal or send an email As you can see you can also add in a delay between the receipt of the trigger signal and the action signal Also one selection on the top part is Sched This allows the RUC to send a UPB signal based upon a time of day Also recognize that you can t send the trigger signal from the RUC the trigger signal must come from a source other than the RUC Updating Firmware This chapter provides information about updating your RUC with new firmware From time to time WMT will provide new enhanced firmware that will offer new features for your RUC This new firmware will be provided through our website via email or on a CD Before attempting to upgrade your firmware make sure you look at all your settings and record them so that you can reenter them once the firmware update is complete Later versions of the firmware do provide a Backup Restore function to allow yo
11. part Sending part Sending part Sending part Programming Complete J s g Modify IP Address 192 168 1 73 Update Capture Target Stop Capture Locate LIA Reset LIA Notice that it tells you that programming is complete Also recognize that depending upon the update there could be more lines that 12 Here is the final screenshot showing final results Confidential amp Proprietary to Web Mountain Technologies not to be disclosed 12 Programming Complete LIA ID B4CB IP address 192 168 1 73 LIA Status 4008 in loader mode finished programing file Control PDU Seq 12460 Data PDU Seq 00 LIA ID B4cB IP address 192 168 1 73 LIA Status 4000 in loader mode Control PDU Seq 12461 Data PDU Seq 00 ha Now you re done and have successfully programmed your RUC with the updated firmware Merely click on the X in the right hand corner to shut down the application Now you should do a factory reset on the unit Hold both S1 and S2 down after a few seconds release S1 One of the LEDs will flash quickly After a few seconds both LEDs will flash 3 times After a few more seconds both LEDs will flash 6 times Now you can release S2 The process is complete At this point you can reenter any settings that you had before Confidential amp Proprietary to Web Mountain Technologies not to be disclosed 13 Summary In conclusion this document sho
12. se Inactive Connection in fi 0 minutes HWsrcup LUoroup Cs www HW group com _ _www HW group com Version 3 1 0 I O Serial over gt Multiport driver Confidential amp Proprietary to Web Mountain Technologies not to be disclosed Click on Save Settings to INI file Then click on the tab for Virtual Serial Port HW Virtual Serial Port HW VSP3 Admi UDP Search Virtual Serial Port Settings Advanced General Port Name IP Address Port COM10 7 lt gt 192 168 1 62 z 9761 External NYT Commands Port 2003 VSE LAN Status Status Baud Bits i Counters Parity YSP LAN QUEUE Stopbits RAs 0 0 0 Handflow Tx 0 0 0 Create COM M HWeroup www HW group com _sevew HU group com _ os Yersion 3 1 0 I O Serial over IP Multiport driver Select a COM port you want to use Make sure it is high enough that it doesn t interfere with one of the hardware COM ports on your PC Notice that we used COM10 If you are using the RUC on your local LAN enter your RUC s IP address not the one shown above XXX XXX XXX XXX found on the Networking Configuration page Then you need the port that the RUC will be using to convert serial traffic onto the TCPIP network By default the RUC is set to 9761 At the current time this cannot be changed Now click on the CREATE COM button You will see this Confidential amp Proprietary to Web
13. sed as an Ethernet PIM with Upstart can greatly improve your productivity Acquiring Upstart Upstart is a freely downloadable program from the Web Mountain website Just go to www webmtn com click on Support then click on Downloads Register with your email address then download the file This file is a compressed zip file so you will need to decompress the file somewhere on your PC then double click on the icon for the program to start the installation process on your PC You should be on version 5 1 Build 45 at a minimum Using a Virtual Serial Port When using Upstart locally you merely connect the serial or USB PIM to the PC you are running Upstart on Then within Upstart you tell the software if you are USB or what COM port the PIM is connected to Since there is no local connection when using the RUC we want to fool Upstart into thinking there is Were going to use a piece of software that creates a virtual serial port The recommended software is HW VSP from The Hardware Group freeware that can be downloaded from this site http www hw group com products hw_vsp index_en html Download the latest version and install it on the computer that will run Upstart When installing HW VSP make sure you select Standalone installation not client server and if it asks you if you want to add these applications to your firewall say No Also tell HW VSP to place an icon on your Desktop Connecting the PIM Now that we
14. u to easily backup then restore your settings once you ve done a firmware update NOTE It is important that the Updating process not get interrupted If you are using a laptop that might go to sleep or hibernate after some period of inaction from the mouse or keyboard either disable this or move your mouse occasionally to prevent the laptop from going to sleep To start first download the RUC_Updater zip file from our website or load it from the CD Extract it on to a location on your local PC Here is what you should see in the folder once it s extracted If you look at this folder after the update process you will see that there is one more file an ini file that the process created This is normal and nothing to worry about Confidential amp Proprietary to Web Mountain Technologies not to be disclosed 9 Organize v Include in library v Share with Burn New folder Fil F Recent Places Name Date modified Type Size RUC_Updater cry 5 14 2010 3 10 PM_ CRY File 293 KB g RUC_Updater exe 5 19 2010 12 00 PM Application 606 KB Updater_Starter exe 5 21 2010 1 24 PM Application 332 KB J Libraries B Documents EE d Music E Pictures E Videos Homegroup JE Computer amp Local Disk C T Local Disk D ca WebMtn E a DRV2 Photos H a DRV2 PERSONA a DRV2_Apps a DRV2 WEBMTNL_ GP Photosmart C306 m Gu Network gM BRN008077047AS Ml GATEWAY Ml NETPLACE Se a 3
15. uld allow you to get your new RUC unit up and running very quickly If you need more detailed information please see the full manual on the WMT website And if you have any issues or need technical support please contact Web Mountain at info webmtn com or at 303 627 1856 Confidential amp Proprietary to Web Mountain Technologies not to be disclosed 14