User`s Manual of Digital Clamp Meter

image

Contents

1. make sure that the function switch is turned onto the gear to be measured When the DCV or ACV is above 36V the finger cannot exceed the gear position of the test probe Press the D H keys to power the meter on then the auto power off function will be cancelled VI Use Instructions Note V Q mA jack denoted with V Q not repeated hereinafter DCV Measurement 1 Insert the black test probe into the COM jack and the red test probe into the V Q jack 2 Set function switch in the DCV position 3 Connect the test probe onto the power supply or load to be tested then the display will show the measurement result and the voltage polarity of the point where the red probe is in ACV Measurement 1 Insert the black test probe into the COM jack and the red test probe into the V Q jack 2 Set the function switch in the ACV position 3 Connect the test probe onto the power supply or load to be tested Current Measurement 1 Estimate the current to be tested If it is below 200mA insert the black test probe into the COM jack and the red test probe into the V Q jack 2 Set the function switch in the current position If the tested current is less than 2mA set the function switch in 2000uA position 3 Switch AC and DC with F S key 4 Serially connect the test probe onto the power supply or load to be tested then the display will show the measurement result If the measured current is DC then the display will at the s
2. and the LCD display holds data menu displayed currently press it again to release the Data Hold IV Technical Indicators Accuracy reading word count Ambient temperature with accuracy ensured 23 5 C RH lt 75 calibration warranty period as one year from ex works date uA 200uA O 1uA 2000uA uA 1 8 3 mA 20mA 10uA 200mA 100uA 2 0 3 20A 2A ImA 2 5 10 20A 10mA 2 5 5 500A 200A 100mA 2 5 5 500A 1A 2 5 10 200uA 200mA overload protection 0 2A 250V fuse tube Frequency range 50Hz 60Hz Frequency range for the clamp measurement above 20A 50Hz Display mean Sine virtual value Resistance Q Range Resolution Accuracy 2002 0 10 1 0 3 2kQ 1Q 20kQ 10Q 1 0 2 200kQ 100Q 2MQ 1kQ 20MQ 10kQ 1 2 5 Max open circuit voltage 0 5V Overload protection 250VDC or AC virtual value Diode continuity Range Display value Test conditions Forward test current ie Approximate diode forward voltage approximately 0 6mA DC drop displayed inverse test voltage approximately 1 5V DC When the ON resistance is less than Open cronies voltare approx approx 50Q the buzzer inside will 0 io Be ere sound Dcv V Range Resolution Accuracy 200mV 100uV 2V ImV 0 5 3 20V 10mV 200V 100
3. to power it off If it is idle for long do remove the battery 5 Do not change gears during voltage or current measurement 6 Be sure to clean the housing with wet cloth and mild detergent rather than abrasive or solvent VIII Accessories User s manual Ipcs Test lead 1 set This user s manual is subject to any change without further notice The content in this user s manual is deemed correct if you find any mistake omission etc please contact the manufacturer We will not be held liable for any accidents or harms caused due to your wrong operations The functions set forth in this user s manual shall not be regarded as reasons for applying this product for special purposes MB 3218 01
4. User s Manual of Digital Clamp Meter I General This meter is a latest portable type 3 1 2 digit ARDCM Auto Range Data Clamp Meter of micropower launched by us It can be used to measure ACV DCV AC DC resistance diode forward voltage drop circuit continuity etc This meter has unique super thin and super small design and the Auto Power function It is characterized by exquisiteness firmness simplicity for operation and convenience for carrying thus it is a desirable tool for engineering design labs schools field operations home appliances servicing etc II Features Max allowed voltage between the measuring terminal and the ground 600V DC or 600V rms insulation level CAT II Pollution level II Range Auto Display 3 1 2 digit LCD max display 1999 full symbol display Font height 12mm Polarity Automatic polarity display Auto power off idle for 15min Key tone Full range overload protection Low battery display CJ occurs on the upper part of the LCD External dimensions 195mmx60mmx36mm Weight Approx 170 g including battery Working voltage 3V 1 5VAAAx2 Working current lt ImA Testing speed 3times s Working environment 0 C 40 C 32 F 104 F RH lt 80 III Instructions of Keys trigger mode M H Max Hold Press the key and the LCD display updates data and holds max F S Function Select Used for the ACA DCA switching and ACV DCV switching D H Data Hold Press this key
5. ame time show the current polarity of the point where the red test probe is For uA and mA level and test probe measurement if the AC to be measured is above 200mA measure it with clamp which cannot be used for DC measurement During measurement press the trigger to open the clamp to bite the load to be tested or one conductor of the power supply if two or more than two conductors are bitten the measurement will become void In order to ensure accuracy the measured conductor shall be located in the middle of the clamp The display shows the measurement result If the current is unknown before measurement set the function switch in 500A position and then gradually lower it Note When the clamp is used to measure the current above 10A the buzzer will sound which is normal Warning When the test probe is used for measurement do not input DC or AC above 200mA When the clamp is used to measure the AC about 500A do not last more than 20s In addition do not measure AC above 550A otherwise the meter may be damaged Resistance Measurement Q 1 Insert the black test probe into the COM jack and the red test probe into the V Q jack 2 Set the function switch in the Q position 3 Connect the test probe onto both ends of the resistor to be tested and read the measurement result on the display In case of open input end or overload OL will be displayed Note When 200Q is used it is necessary to short circuit the test probe to test t
6. he resistance of the lead which will be deducted from the actual test Diode Measurement 1 Insert the black test probe into the COM jack and the red test probe into the V Q jack 2 Set the function switch in diode position connect the red test probe onto the positive of the tested diode while the back test probe onto the negative then the display will show the forward voltage drop of the diode in case of open input end or inverse measurement OL will be displayed Continuity Measurement 1 Insert the black test probe into the COM jack and the red test probe into the V Q jack 2 Set the function switch in the diode position press the F S key to enter the continuity measurement state connect the test probe onto both ends of the tested circuit then the display will show the resistance of the tested circuit If the resistance is less than about 50Q the buzzer will sound in case of open input end or inverse measurement OL will be displayed VII Meter Maintenance This meter is a precise digital electronic meter thus never replace circuits or components without permission and pay attention to the following points which is very helpful for you to use your beloved meter 1 Do not input AC virtual value or DCV above 600V 2 Do not measure the voltage when the function switch is located in Q or diode position 3 Do not place the meter in the place of high temperature and high humidity 4 After the measurement is over be sure
7. mV 600V 1V 0 8 3 Input resistance 10MQ Overload protection 700Vrms or 1 000Vp ACV V Range Resolution Accuracy 2V ImV 20V 10mV 0 8 5 200V 100mV 600V 1V 1 2 5 Input resistance 1OMQ Frequency range 40Hz 400Hz below 200V 40Hz 100Hz 600V Display mean Sine virtual value Overload protection 700Vrms or 1 000Vp DC Az Gear Range Resolution Accuracy uA 200uA 0 1uA 2000uA luA 1 2 3 mA 20mA 10uA 200mA 100uA 1 5 3 Overload protection 0 2A 250V fuse AC Amo Gear Range Resolution Accuracy Overload protection 250VDC or AC virtual value V Notices Before use check if the battery voltage is enough If the battery voltage is insufficient the display will show the symbol of In such case test after the battery is replaced When the current at uA or mA level is measured if the input has no response check if the fuse tube inside is broken When replacing the fuse tube or the battery make sure the test probe is disconnected from the tested circuit and always use the fuse tube or battery of the same specifications and type Warning No measurement is allowed when the rear cover or the battery cover is not installed properly in order to ensure safety The symbol ZN on the test probe panel indicates the input voltage or current cannot exceed the indicated value It is possible to measure display higher voltage or current but the meter may be damaged Before measurement