Home

CP5-Series User Manual - American Weigh Scales Inc

image

Contents

1. Tap the UNIT key until the desired weighing unit is indicated on the right side of the display TL 330 amp TL 440 Units Ib pound gt oz ounce gt kg kilogram Vil Hold Setting You can change the scale s hold setting between three different modes Auto Hold Peak Hold and No Hold To change the hold setting 1 Tap the HOLD key The display will show a letter at the left side of the display to indicate the current hold setting These are A 7 Auto Hold Weight is locked on the display when stabilized P Peak Hold Highest weight is locked on the display Good for measuring forces N No Hold The weight does not lock on the display Vill Calibration Calibration and adjustment are performed at the factory There is no need to calibrate unless you are experiencing issues Only advanced users should calibrate and adjust the scale To check calibration 1 Place the required calibration weight on the scale and note the displayed value 2 Ifthe displayed value is not within acceptable tolerance see chart on next page adjustment is required TL Series Manual Model Acceptable Calibration Recommended Tolerance Weight Accuracy Class TL 330 0 3kg 100kg OIML M3 TL 440 0 6kg 100kg OIML M3 IX Adjustment 1 With the scale OFF ON OFF TARE keys at the same press and hold the UNIT and ime until a random number shows on the LCD If you wish to cancel press the H
2. FALUS American Weigh Scales TL Series User Manual TL 330 330lb x O 2lb TL 440 440lb x O 5Ib Copyright 2012 American Weigh Scales Inc All rights reserved Rev 2 0 TL Series Manual Thank you for purchasing the American Weigh TL Series hanging scale Please read all operating instructions carefully before use Scales are precision measuring devices and should always be handled with proper care To ensure years of reliable service keep these simple tips in mind Do not exceed the scale s maximum capacity Store your scale in a clean dry location Dust dirt and moisture can accumulate on the weighing sensors and electronics causing inaccuracy or malfunction Avoid using your scale in close proximity to strong radio wave emitting devices such as cordless phones Suspend the scale from a stable point free from vibration Do not drop items onto the weighing hook This may cause damage to the load sensor Avoid dropping your scale The warranty does not cover damage due to rough treatment or overload Check the batteries first if you are having any trouble with your scale This simple step can remedy most scale issues Calibration is performed at the factory Only experienced users should perform calibration when the scale requires it I Part List 1 Scale 2 S Hook and Shackle 3 AAA Batteries x2 ll Key Description 1 ON OFF TARE Tap to turn the scale on or re zero the s
3. OLD key otherwise continue to step 2 2 Make sure there is no weight on the hook then press the ON OFF TARE key once more The display will flash Zero followed by the required weight in KG 100kg Place the required weight on the scale hook e 4 Wait briefly for the weight to stabilize then press the ON OFF TARE key one last time to confirm a X Troubleshooting Problem Scale will not turn on Solution Check the batteries and ON OFF lock The display will show PASS Calibration is complete Problem Display will not stabilize Solution Make sure the weight is stable on the hook and not shaking or swinging Problem Displayed weight is inaccurate Solution Perform a calibration adjustment XI Error Codes 1 OUTZ Zero range has shifted Perform calibration adjustment If the problem persists the load cell may be permanently damaged due to overloading 2 O_Ld Maximum capacity exceeded Remove the extra weight to avoid damaging the load cell 3 Lo Low Power Replace the batteries XII Specifications TL 330 TL 440 Max Capacity 150kg 330lb 200kg 440lb 52800z 70400z Readability 0 1kg 0 2Ib 1oz 0 2kg 0 5lb 2oz Min Capacity 0 3kg 0 6lb 3oz 0 6kg 1 5lb 6oz 2 x AAA Dimensions 6 0 x 2 8 x 1 2 in Hook Dimensions Gap 0 7 in Throat 1 3 in Warranty 10 Year Limited Warranty
4. cale Hold to turn the scale off 2 UNIT Key Tap to change the unit between LB OZ or KG Hold to change auto off setting see V 3 HOLD Key Tap to change the scale s display hold mode between Auto Hold Peak Hold and No Hold see VII Ill Battery Installation TL Series Manual 1 Before using the scale for the first time check the battery compartment and remove any plastic insulation strips or packaging that may be in place to prevent battery drainage during shipping storage 2 If you are replacing the batteries make sure the positive and negative contacts are properly aligned IV Operation 1 Press the ON OFF TARE key to turn the scale on 2 Wait for the display to display zero 3 Hang the item to be weighed from the weighing hook 4 Observe the weight on the display 5 To re zero the scale tap the ON OFF TARE key 6 To turn the scale off hold the ON OFF TARE key V Auto Off Setting This scale has a selectable auto off feature 1 Press and hold the UNIT key to toggle the auto off setting on or off A message will display on the screen to indicate your selection AUTO Auto Off is Enabled Scale will turn off after 2 minutes of non use OFF Auto Off is Disabled Scale will remain on until turned off manually AU 1 uF VI Changing the Unit of Measure ei This scale can read in LB OZ or KG To change the weighing unit follow these instructions 1

Download Pdf Manuals

image

Related Search

Related Contents

Philips Grooming kit QG3193  Impresora 3D Cube® - Amazon Web Services  Manuale di istruzioni testo 845  armado  MANUAL DE UTILIZAÇÃO PRF-500T4  Generic Slave DTM for PROFIBUS DP Slave Devices  LEADER EVAPORATOR LTD. 49 Jonergin Drive Swanton, Vermont  Manuale  Cables Direct XXURT-601B networking cable  

Copyright © All rights reserved.
Failed to retrieve file