PSTN Home Alarm System

image

Contents

1. a ao bes s 8 User Manual Main Host 5 2 View pa i s A r a Dip DDA ieee Qe eee aa cn FF all Front View Side View Back View PST TEL99E User Manual PST V1308002 001 SHENZHEN PROFESSIONAL SECURITY TECHNOLOGY Co LIMITED 5 3 Functional Parts LED screen display SF BF CF 99 F1 F3 1 98 LED indicator POWER ALARM SET PHONE Microphone Function keyboard ARMING INTELLIGENT DISARMING ALARM Digital Keyboard gpm aD a gt Ga aa ARWING INTELLIGENT DESARM EG ALAEI Microphone LED Indicator Digital Keyboard LED Digital dispaly Function Keyboard ARM INTELLIGENT ARM Disarm Emergency alarm Telephone line disconnect No add sensor Alarm zone display Power LED light power supply working normal Alarm LED light alarm system alarm SET LED light the alarm system into setting status PHONE LED light access telephone line work normal Personal remote monitoring ARMING LED light the alarm system system into arm status INTELLIGENT LED light the alarm system system into intelligent status DISARMING LED light the alarm system system into disarm status ALARM LED light the alarm system system into alarm status setting alarm system system function 6 PST TEL99E User Manual PST V1308002 001 R CHINAPST SHENZHEN PROFESSIONAL SECURITY TECHNOLOGY Co LIMITED Battery ON OFF Switch Telephone Telephone outside line
2. Siren Connector Power Input Connector Wireless Antenna Antenna Wireless antenna Connect LINE1 to telephone uses telephone wire LINE1 of standard package list LINE2 Connect LINE2 to telephone out line Connect DC12V adapter uses power adapter of POEA standard package list SIREN Connect siren uses siren of standard package list ON OFF Power on battery or power off battery 5 4 Install accessories Install the Door sensor The door window magnetic sensor includes two parts The sensor will send the wireless signal to main unit immediately when the two parts depart more than 10 30mm The picture of the installation is as follows Alarm Indicator Adhesive tape Low battery indicator CHINAPST SHENZHEN PROFESSIONAL SECURITY TECHNOLOGY Co LIMITED In some circumstances the wired amp wireless Infrared Fence detector is more appropriate than magnetic sensors i e veranda picture window balcony boundary wall Se VEN SELLE N N DA a wireless glass break detector can also be used for window see below The sensitivity is adjustable Wireless scroll steel door magnetic sensor for scrolling steel door Installation Please see below picture lt is triggered when the two parts are separated to 3cm 5cm PST TEL99E User Manual PST V1308002 001 R Install PIR motion sensor PIR refers to passive Infra red A Passive Infra red Sensor is an electronic device tha
3. to arm Press 5 to disarm Press to affirm and hang up 9 Handing Incoming Alarm Phone Calls When sensors are triggered or emergency help the alarm panel will dial up the setup telephone numbers automatically and give alarm rings based on settings If the host s phone is in use or not able to connect the system will dial next alarm phone until it is dialed and hosts confirm It will play records after receiving alarm phone and the operation methods are similar to remote setup 10 Reset Factory Settings Command 80000 Description 0000 is default password All settings will be cleared except all the registered sensors 11 Copyright and Disclaimer Copyright 2013 PST All rights reserved The user manual may be changed without prior notification This user manual or any part thereof may not be reproduced for any purpose whatsoever without the written authorization of PST or transmitted in any form either electronically or mechanically including photocopying and recording In no event shall PST be liable for direct indirect special incidental or consequential damages including but not limited to economic loss personal injury and loss of asset and property arising out of the use or inability or illegality to use the product or documentation lf you encounter any problems when using our products and cannot solve them by yourself please contact our technical support team by writing an E Mail to michael chin
4. 7 1 Set up Arm Press f button on the remote controller and the LED display SF means system Armed 7 2 Set up Disarm Press m button on the remote controller and the LED display CF means system Disarmed 7 3 Emergency Alarm Press button on the remote controller for emergency help And the LED display 99 Press A button on the remote controller one time is silent alarm while press Mbutton twice or long time the siren will sound 7 4 Intelligent Arm Press s button on the remote controller and the LED display bF means system Intelligent Armed 8 Remote Control the system You can use any telephone to dial the numbers of the system and it will put on automatically get through after system detecting the ring times you have been setup When you hear the beep input passwords two sounds when the password is wrong if the password input wrongly 3 times or no any operations within 20 seconds the phone will hang up automatically and if it is correct you can have remote control of the system press after accomplish all operations then you can implement other operations and hang up telephone Press 1 to monitor Press 1 again for monitor 20 seconds more Press 2 to start the siren 273 SHENZHEN PROFESSIONAL SECURITY TECHNOLOGY Co LIMITED eHINAPST PST TELOGE User Manual PST v1308002 001 Press 3 to stop the siren Press 4
5. PSTN Home Alarm System User Manual Model PST TEL99E lt i J I INDICATOR POTER ALARM SET PHONE ARMING XTELLIGENT DISARMING ALARM Please read this user guide carefully before operation and installation SHENZHEN PROFESSIONAL SECURITY TECHNOLOGY Co LIMITED eHINAPST PST TELOGE User Manual PST v1308002 001 Contents Te POGUE OVON OW ase eat case ecto este E nes eactenuaene asennad aeseneasee 3 2a AI FONCION S FO UTO eea EAEE EEE E 3 LF VOU SOUCY aioe gece dese citeesere EEEE E E E EEEE 4 As TELISE AA CLONING ee E E 4 Di ACTING Sle e E E E E E A E A ueeeasnimoseumeuseiies 5 Dall Sll e aCKAGC LIS EE E E EE E 5 KL NION a E E EE EE 5 J FUNCIONI FS e E e E E E E E EE E EE E E E E 6 DA Connecting and WAS tall AU OM sssrin EEE ENE EEA 7 6 Operation steps by keyboard SettinG ccccccssesecceeeeeeceeseecseeeeeeeeeeeeseeeeesseeeeeseas 10 6 1 Open Close password protection function Change user s password 10 6 2 Adjust the volume of alarm siren ssennsnnnennnensnrresrrnenrnrrrnrrrsrrrerrrrreerrreree gt 10 6 3 Set up alarming telephone NUMDETS cccecccseeecececeeeeceeeeceueessueeceeessaes 11 6 4 Delete telephone numbers cccecccseecceeeeceeeeceeeeceeecueesseeeseeeeseeeseeeesaes 11 6 5 Set up siren sound time when system alarming ccccseeeeeeeeeeseeeeeeeeees 11 COSER Aa A ay e E EEEE E EEE EE EE EE EE EE E EEEE 11 OF
6. SS tara T AO o e E E EERE E AAEE 11 6 8 Set remote telephone ringing tiMES ccccccccseececeeececeeeeesaeeeeseeseesaeeesaees 12 6 9 Set siren sound when using the remote CONtOl ccccccceeeceeeeeeeeeeeeeaeees 12 6 10 Sel DUZ r SOUMG ON Ot oee e E E E E E Ei 12 6 11 Learning and delete detectors ccccccsecccseeeceeeeceeeeceeeessusesseeessaeesseeeess 12 CIZ oP MOOS OZONE eee ee E EE E 12 6 13 Inquiry alarm defense ALeCa cceccccsscecceeeecceeeeceeececeeeeecseeeecseesesseeeensass 13 6 14 Telephone line anti cut function cccceececeeeeceeeeceeeeseeeesseesseesseeesseeeess 13 7 Remote Controller Key fob Description cc ccccce cece eee e eee eeee eee eeeee es remei 13 Ts CU UD e E 13 D2 SOV Up DIS ie E E EA E E 13 7 gt EME ONV AA ea E E A E EEEE S 13 FA MSM ATM i E E dah daton EAE ET 13 Rene CONTO SY e ee EE A E E E EE EES 13 9 Handing Incoming Alarm Phone CalllS ccccccccceeceeceeceeseeeeeeeeeeseeeeesseeeesaaeeesaeeeeas 14 TO Reet Fac C UNOS eneen eeen enno Eeee EE a eee EEE ERE EE enee aanshan shucectan EEEE E EG 14 Tg OOY OG ala DISCE E rea AAA I EERE EREE ER NARR 14 12 OPa conna LIS eee E E E E 15 SHENZHEN PROFESSIONAL SECURITY TECHNOLOGY Co LIMITED eHINAPST PST TELOGE User Manual PST v1308002 001 1 Product Overview TEL99E is a PSTN intelligent home alarm system This LED display alarm system is equ
7. a0o00 0000 SHENZHEN PROFESSIONAL SECURITY TECHNOLOGY Co LIMITED eHINAPST PST TELOGE User Manual PST v1308002 001 3 For Your Safety Read these simple guidelines Not following them may be dangerous or illegal Proper Connection When connecting with other device read carefully its manual so as to carry out correct installation Do not connect it to other incompatible devices Qualified Accessories Use original parts and peripheral equipments to avoid damage to TEL99E Water Resistance TELQ99QE is not water resistant Keep it dry Install it inside the house Confidential Phone For safety reason do not tell other people the telephone Number number of your TEL99E without taking precautions of security settings 4 TEL99E Characteristics Items Specification Power Supply DC12V 1A Backup Battery Ni Hi AAA 6 DC7 4V Standby current lt 35 mA Alarm current lt 450 mA Wireless frequency 433MHz Support wireless EV1527 300K 2262 1 5 4 7M sensors Wireless distance 100m open LED screen display time Arm Disarm Stay arm Alarm Setting Operating 10 to 50 C temperature Humidity 5 to 95 Non condensing Dimension 33 25 7 5cm Weight 1 2Kg PST TEL99E User Manual PST V1308002 001 R 5 Getting Started This section will describe how to set up your TEL9QE 5 1 Standard Package List TEL99QE is supplied in a box which includes Door Sensor PIR Bracket j _ Adhesive Paper
8. apst com We will be pleased to help you 14 PST TEL99E User Manual PST V1308002 001 SHENZHEN PROFESSIONAL SECURITY TECHNOLOGY Co LIMITED 12 Operation Command List Add or Delete all of the remote controller 02 Delete allofthe detecor SSG 1 XXXXXXXXXXK 2XXXXXXXXXXH IXXXXXXXXXXH XX X Set up alarm telephone numbers telephone H4XXXXXXXXXX Set up number telehone HOXXXXXXKXXXXK HEOXXXXXXXXXXK 1 2 3 Delete the telephone numbers 4 5 6 Set up siren sound for the remote 2 1 21 On control 20 20 Off Function 99 99 Off Set up the buzzer sound 98 98 On 00 00 No sound Set up volume of alarm siren 01 01 Have sound 51 51 On Telephone line anti cut function 50 50 Off 8XX0 Bypass mode 8XX1 Common mode 8XX2 Intelligent mode Mode Set up mode of zones 8XX3 Emergency mode 8XX4 Multi Zones Triggered Mode 8XX5 Delay alarm mode 8XX 7 Repeat triggered mode Open Close password protection 11 11 On function 10 10 Off Password numbers XX 00 99 zones Input password 0000 Modify password new password new password Reset Factory Settings 80000 15
9. er ringing 3 times 60 means no ringing times 6 9 Set siren sound when using the remote control Command 21 Description The siren have reminder sound when you press remote control Command 20 EG i ae SHENZHEN PROFESSIONAL SECURITY TECHNOLOGY Co LIMITED eHINAPST PST TELOGE User Manual PST v1308002 001 Description The siren off sound when you press remote control only have buzzer sound on the remote control to turn on the siren sound 6 10 Set buzzer sound on off Command 99 Description Off the buzzer sound Command 98 Description Open the buzzer sound 6 11 Learning and delete detectors Command 0 Description Learning Remote controller After you press 0 on the alarm panel keyboard then press any button of the remote controller within 10 seconds A long Bi sound means successfully Command 01 Description Learning detectors After you press 01 on the alarm panel keyboard then trigger the detector within 10 seconds A long Bi sound means successfully Command 8xx 00 99zones number Description Learning detector to the designated zones number e g 816 means learning a detector to zone 16 Command 02 Description Delete all of the remote controllers Command 8996 Description Delete all detectors 6 12 Set up mode of zones Command 8xxA Description xx means 00 99 zones A means mode of zones 0 8 0 bypass mode the zone will not wo
10. ipped with PSTN technologies and suitable for both home and commercial use It uses the PSTN landline networks with intelligent alarm system It is a choice of stability reliability Security and user friendliness Features are very practical cost effective completed configuration and ease of use This LED display alarm can integrate with a lot of alarm accessories including door sensor smoke detectors gas detectors emergency buttons and other accessories to build a powerful security setup It has been widely used in homes factories schools shops convenience stores financial and banking workplace community centre and residential area to provide protection to valuable assets 2 Main Functions amp Features TEL99E has the following main functions and features 99 Wireless Zones with LED display PSTN telephone line working ways LED indicator Arm Disarm Stay arm Alarm Setting Password protection function 5 groups of call phone number and SMS number 1 group of emergency phone number and SMS number 0 99secs delay alarm setting 0 99secs delay arm setting 0 30mins Siren ringing time setting Ringing times setting Stay intelligent arm Multi Zones Triggered Mode 2 or more than 2 zones Repeat triggered alarm function sensor alarm after triggered twice Telephone line anti cut function Remote control the TEL99E stop the siren sound or start the siren sound Remote Monitoring Arm Disarm Reset factory setting 00000 GOeve
11. oper operations while two short sounds for wrong settings 6 1 Open Close password protection function Change user s password Command 11 Description open password protection function Note Open this function you need first input password before operation keyboard the factory password is 0000 input password 0000 Command 10 Description close password protection function Note close this function you no need input password before operation keyboard Command 7xxxx 4 numbers new password xxxx 4 numbers new password Description modify passwords 6 2 Adjust the volume of alarm siren Command 00 Description silent alarm the siren no sound when the system alarm Command 01 Description the siren sound when the system alarm 6 3 Set up alarming telephone numbers Command 1xxxxxxxxxxxxx telephone number Description 1 means set the first group telephone number you can receive SMS and call when system alarm Command 2xxxxxxxxxxxxx telephone number Description 2 means set the second group telephone number you can receive SMS and call when 10 eHINAPST PST TELOGE User Manual PST v1308002 001 SHENZHEN PROFESSIONAL SECURITY TECHNOLOGY Co LIMITED system alarm Command 3xxxxxxxxxxxxx telephone number Description 3 means set the third group telephone number you can receive SMS and call when system alarm Command 4xxxxxxxxxxxxx telephone number Descrip
12. rking in anytime 1 common mode the zone will alarm when system ARMING 2 intelligent mode the zone will not working when system INTELLIGENT ARMING 3 Emergency mode the zone will working in anytime it can alarm when system DISARMING 4 Multi Zones Triggered Mode You must setup 2 or more than 2 zones for Multi zones for example 5 th zone and 10th zone For multi zones triggered mode only all the detectors you have registered for these zones you have setup for multi zones are triggered within 30s the alarm panel will alarm 5 delay alarm mode the system not immediately alarm after set up delay alarm mode 6 Repeat triggered mode when the detector is triggered once the system will not alarm immediately only when it is triggered again within 30s after the first trigger the system will alarm 7 Doorbell mode the system will ding dong when detector be triggered SHENZHEN PROFESSIONAL SECURITY TECHNOLOGY Co LIMITED eHINAPST PST TELOGE User Manual PST v1308002 001 6 13 Inquiry alarm defense area Command x 0 9 Description Directly press 0 9 to inquiry the latest 10 alarm events and display alarm defense area 0 means the latest one 6 14 Telephone line anti cut function Command 51 Description the system will alarm when telephone lines disconnect or failure Command 50 Description the system will not detect telephone lines disconnection or fault 7 Remote Controller Key fob Description
13. t detects the motion or movement of some person or animal by sensing the heat emitted from the body Installation 70 degree i ja Wireless PIR motion sensor no y Horizontal angle 90 110 degree i gt Vertical angle 30 50 degree E __ Surveillance Area 1 3m i Install smoke gas detectors a Wireless smoke detector This smoke detector detects smoke by a couple of infrared diodes which is suitable for detecting the TEST BUTTON INDICATOR i l 5 gt i f b Wireless gas detector The product is ceiling mounted gas detector with high stability It is used for detecting leaking gas and suitable for the safety of residential house villas hotels boarding house etc Detecting the gas heavier than air installation height from floor 0 3m 1 0m semi diameter to gas sources lt 1 5m detecting the gas lighter than air installation height from ceiling 0 3m 1 0m semi diameter to gas sources lt 1 5m PST TEL99E User Manual PST V1308002 001 SHENZHEN PROFESSIONAL SECURITY TECHNOLOGY Co LIMITED Open or close i manipulator Poo Ry Test button DIAMETER Power LED green 3M a AS EN R F 1 4 Perse ag oe E Sa P P Je g a r Rt T 6 Operation steps by keyboard setting Note When setting by the keyboard all the settings can be carried out under the undefended situation with a long ring for all the pr
14. tion 4 means set the forth group telephone number you can receive SMS and call when system alarm Command 5xxxxxxxxxxxxx telephone number Description 5 means set the fifth group telephone number you can receive SMS and call when system alarm Command 6xXxxxxxxxxxxxx telephone number Description 6 means set the sixth group telephone number you can receive SMS and call when system alarm This is emergency phone numbers 6 4 Delete telephone numbers Command 1 Description delete the first group telephone number Command 2 Description delete the second group telephone number Command 3 Description delete the third group telephone number Command 4 Description delete the forth group telephone number Command 5 Description delete the fifth group telephone number Command 6 Description delete the sixth group emergency telephone number 6 5 Set up siren sound time when system alarming Command 9xx 00 30minutes Description e g 95 the siren will sound 5 minutes when the system alarm 6 6 Set up alarm delay Command 7xx 00 99seconds Description e g 30 the system will alarm after sensor is triggered 30 seconds 6 7 Set ARMING delay Command 4xx 00 99seconds Description e g 430 the system will auto ARMING after press ARM key 30 seconds 6 8 Set remote telephone ringing times Command 6x 0 9times Description e g 63 if will automatically get through aft

Download Pdf Manuals

image

Related Search

Related Contents

PowerWave 16 User guide  Manual de Usuario - Observatorio Astronómico Nacional de San  Cybex VR3® Hip Abduction Owner`s and Service Manual Strength  Tecumseh AWG4520EXG Drawing Data  Service manual  Manual de instalación del eToken  Soy Brillante.  Pelco System 9760 Webcam User Manual  OVENS PYROLYSIS  Harbor Freight Tools 90799 User's Manual  