Home
Technical Data Sheet
Contents
1. 0 2 6500 2 Portable Appliance Testers Ordering information The Fluke 6200 2 comes with the following e 6200 2 PAT e User s manual on CD e Quick reference guide e Hard Carrying Case e Test Lead e Test Probe e Crocodile Clip e Mains Cord The Fluke 6500 2 comes with the following e 6500 2 PAT e User s manual on CD e Quick reference guide e Hard Carrying Case e Test Lead e Test Probe e Crocodile Clip e Mains Cord e USB Stick e USB Cable 2013 Fluke Corporation All rights reserved Data subject to alteration without notice Printed in U S A 11 2013 6000093A_EN Pub_ID 12135 eng Rev 03 Modification of this document is not permitted without written permission from Fluke Corporation Portable Appliance Testers Manufacturer Part Kit Contents Number FLUKE 6500 2 DE KIT Fluke 6500 2 PAT Tester SPSCAN6000 scanner APP1000 barcode appliance labels Fail250 labels PASS 560R Appliance PASS labels EXTL100 extension test lead adaptor DMS 0702 PAT appliance tester software and all standard accessories FLUKE 6500 2 DE DMS BASIC Fluke 6500 2 PAT Tester PASSS60R appliance pass labels EXTL100 extension lead test adaptor DMS 0702 PAT appliance tester software and all standard accessories FLUKE 6500 2 DE All standard accessories listed in datasheet FLUKE 6500 2 UK All standard accessories listed in datasheet FLUKE 6500 2 UK BASIC KIT Fluke 6500 2 PAT Tester PASS560R appliance pass labe
2. 99 MQ 0 1 MO 20 to 199 9 MQ 1 MO 200 to 299 MQ 500 V dc 0 25 at 500 KQ load or 6500 2 only 250 V dc 0 25 at 250 KQ load gt 1 mA at 500 KQ load lt 15 mA atO 0 lt 0 5 s for 1 pF Operational up to 1 pF O to 1 99 mA AC 4 2 counts 0 01 mA 2 KQ Probe The appliance under test is energized at mains potential Display range Accuracy Resolution Test voltage UK Display range Accuracy Resolution O to 19 99 mA AC 2 5 3 counts 0 01 mA 100 V AC 20 Oto 134A 4 2 counts O 1A The appliance under test is energized at mains potential AU Display range Accuracy Resolution OAto104A 4 2 counts 0 1 A The appliance under test is energized at mains potential Display range UK AU Accuracy Resolution 230 V mains 0 0 VA to 3 2 KVA 0 0 VA to 2 4 KVA 5 3 counts 1 VA O to 999 VA 0 1 KVA gt 1 0 kVA The appliance under test is energized at mains potential Display range Accuracy Resolution O to 19 99 mA 4 4 counts 0 01 mA The appliance under test is energized at mains potential Accuracy at 50 Hz Overload protection Warning threshold 2 3 counts 300 V rms 25 V rms RCD Test Trip Current Operational error 6500 2 only Nominal Accuracy RCD Test Trip Time Standard requirement 61557 Part 6 tolerance of rated test current 6500 2 only O to 10 Operational error 10 RCD
3. FLUKE Fluke 6200 2 6500 2 Portable Appliance Testers Technical Data Perform more tests each day The low weight small size one touch solution The Fluke 6200 2 and 6500 2 PAT testers are low weight small size one touch solutions with redesigned auto test capabilities to help you increase the number of portable appliance tests completed each day The 6200 2 and 6500 2 are designed to enable you to work faster without compromising safety yours or your Customer s Fluke simplifies portable appliance testing e Dedicated key for each test for one touch testing e Pre set pass fail levels to save time e Large backlit display for easy reading e Single mains socket for appliance connection e Separate IEC socket for easy mains extension lead testing e Detachable test leads for quick field replacement e Integral carrying handle e USB port for printing The Fluke 6500 2 delivers all of this capability plus e Integral QWERTY keyboard for rapid data entry J e USB flash drive capability for storage and transfer to PC e Large backlit graphic display _ We w e Pre set auto test sequences for user convenience RES rae z e Integral site location and description codes for a faster data processing er surety ni ma e Memory review facility for more on site control Test specifications The accuracy specification for the display range is defined as reading digit counts at 23 C 5 C l
4. ls EXTL100 extension lead test adaptor DMS 0702 PAT appliance tester software and all standard accessories FLUKE 6500 2 UK KIT Fluke 6500 2 PAT Tester SPSCAN6000 scanner APP1000 barcode appliance labels Fail250 labels PASS 560R Appliance PASS labels EXTL100 extension test lead adaptor DMS 0702 PAT appliance tester software and all standard accessories FLUKE 6200 2 UK KIT Fluke 6200 2 PAT Tester IRP1 register for PAT log book FAIL250 labels PASSS60R appliance pass labels EXTL100 extension lead test adaptor and all standard accessories Contact Information www Farnell co uk www Newark com
5. t 75 RH Between O C and 18 C and between 28 C and 40 C accuracy specifications may degrade by O 1 x accuracy specification per C The measurement range meets the service operating errors specified in EN61557 1 1997 EN61557 2 1997 EN61557 4 1997 EN61557 6 1997 DIN VDEO404 2 Power on test Earth bond test R Insulation test R Touch current test Substitute leakage current test Load Leakage Test Load current Load Leakage test Load power Load Leakage test Leakage current 2 Fluke Corporation Fluke 6200 2 6500 2 Portable Appliance Testers The test indicates reversed L N missing PE and measures the mains voltage and frequency Display range Accuracy at 50 Hz Resolution Input impedance Maximum input mains voltage Display range Accuracy after Bond Test zeroing Resolution Test current Open circuit voltage Bond test zeroing Display range Accuracy Resolution Test voltage Test current Auto discharge time Max capacitive load Display range Accuracy Resolution Internal resistance via probe Measuring method 90 V to 264 V 2 3 counts 0 1 V 1 V model 6200 gt 1 MO 2 2 nF 264 V O to 19 99 Q 2 5 4 counts 0 01 Q 200 mA AC 0 40 into 1 99 Q 25 AAC 20 into 25 mQ at 230 V gt 4V AC lt 24V AC Can subtract up to 1 99 0 O to 299 MQ 5 2 counts from 0 1 to 300 MO 0 01 MQ 0 to 19
6. type AC General Purpose 30 mA Display range 310 ms Resolution 0 1 ms Accuracy 3 ms Trip time limit at 100 30 mA 300 ms Trip time limit at 500 150 mA 40 ms Environmental specifications Operating temperature O to 40 C Relative humidity Non condensing lt 10 C 95 from 10 to 30 C 75 from 30 to 40 C Safety specifications Safety rating Complies with EN61010 1 3rd edition CAT II 300 V pol 2 German version only DIN VDEO404 1 and DIN VDE0404 2 IEC EN 61557 part 1 2 4 6 10 CAT II 300 V pol 2 Mechanical and general specifications Power supply 230 V 10 15 50 Hz 2 Hz or 6500 2 only 110V 10 15 50 Hz 2 Hz Power consumption 13 W typical idle Tester 60 W max during 25A Bond Test Storage Temperature 10 C to 60 C Corrosion 70 C 95 RH for 5 days max Seain 0 ence 0 omnea O OSS meo owo OOOO mmy SW 3 Fluke Corporation Fluke 6200 2 6500 2 Portable Appliance Testers Kit configuration and contents vary by region Fluke The Most Trusted Tools in the World Fluke Europe B V Fluke UK Ltd P O Box 1186 52 Hurricane Way 5602 BD Eindhoven Norwich Norfolk The Netherlands NR6 6JB Web www fluke co uk United Kingdom Tel 44 0 20 7942 0700 For more information call Fax 44 0 20 7942 0701 In Europe M East Africa 31 0 40 2 675 200 or Fax 31 0 40 2 675 222 E mail industrial uk fluke nl Web www fluke co uk 4 Fluke Corporation Fluke 620
Download Pdf Manuals
Related Search