1. Driver for Linux Configuration Section Page 14 X EMULEX Table 3 Ipfc Static Parameters Requires a driver reload to change Continued Visible Variable Default Min Max Comments using sysfs Ipfc_enable_hba_ 1 0 heartbeat Controls the HBA heartbeat No heartbeat disabled logic in the driver If 1 heartbeat heartbeat is enabled and enabled the heartbeat logic detects that the HBA is non functional the driver will shutdown the HBA lpfc_enable_hba_reset 1 0 hba reset Controls whether No disabled hba_resets will be allowed 1 hba reset by the driver to pass to the enabled HBA This is used as a debugging tool Ipfc_enable_npiv 0 0 1 This parameter controls the Yes driver s ability to use NPIV to create virtual ports It defaults to off 0 which prevents the driver from creating any virtual ports When enabled set to 1 it enables you to create and delete virtual ports if supported by the fabric NOTE You can only enable vports on 4G and 8G HBAs Ipfc_fcp_class 3 2 3 The Fibre Channel class for Yes FCP data transmission Ipfc_hba_queue_depth 8192 32 8192 The maximum number of Yes FCP commands that can queue to an Emulex HBA Ipfc_lun_queue_depth 30 1 128 The default maximum Yes commands sent to a single logical unit disk Ipfc_scan_down 1 0 Off 1 On Selects method for Yes scanning ALPA to assign a SCSI ID Ipfc_sg_seg_cnt 64 64 256 Controlls t
2. lpfc install Driver for Linux Installation Section Page 3 Once the Ipfc install script has completed successfully the Emulex Ipfc driver is loaded and Fibre Channel disks that are properly connected to the system are accessible Reboot the sys tem now to enable the newly added driver options in the ramdisk You can also reboot the sys tem later if you wish Driver Kit Install Script Options The following options are available for use with the Emulex install script for Linux h help Prints a help message describing command line parameters e u uninstall Uninstalls the currently installed driver kit Driver Kit Directory Structure After installation the following directory is created on the system Table 1 Driver Kit Directory Structure Directory Description usr src lpfc Driver source files Installing the Driver on Unsupported Linux Distributions The driver kit supports the Linux distributions listed on page 1 As of Linux kernel 2 6 12 the Ipfc driver is distributed with the Linux kernel sources To install the Emulex Ipfc driver on an unsupported distribution of Linux refer to the distribution s Web site or http kernel org Note The Emulex version 8 2 driver for Linux is not intended for and will not operate on any kernel prior to 2 6 12 If you are using an earlier 2 6 kernel you must use the Emulex driver for Linux version 8 0 16 x Driver for Linux Install
3. To find the vports that have been created by a physical port you can list the fc_host s device directory for the physical port This gives you a link to the fc_host and scsi_host directory as usual but also displays a list of vports in the form of hostx that were created on this physical port In the previous example host6 is a vport of physical port host5 Vport sysfs Entries The following table describes vport sysfs entries Note Vport sysfs entries in Table 5 are only present if the driver was loaded with lpfc_enable_npiv enabled Table 5 Vport sysfs Entries Vport sysfs Entries Type fei Location and Description npiv_vports_inuse read integers sys class scsi_host hostX npiv_vports_inuse only This entry displays the number of vports that were created on this fc_host This sysfs entry will only exist if the vport_create and vport_delete sysfs entries exist If an fc_host does not support NPIV then this sysfs entry may not exist NOTE Use this sysfs entry along with max_npiv_vports to determine whether the maximum number of vports have been created on this fc_host Driver for Linux Configuration Section Page 23 Table 5 Vport sysfs Entries Continued Vport sysfs Entries Type Range Input Location and Description max_npiv_vports read only integers sys class scsi_host hostX max_npiv_vports This entry displays the maximum number of vports that are suppor
4. elx_mes0225 Device Discovery completes DESCRIPTION This indicates successful completion of device re discovery after a link up DATA None SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational elx_mes0226 Device discovery completion error DESCRIPTION This indicates that an uncorrectable error was encountered during device re discovery after a link up Fibre Channel devices will not be accessible if this message is displayed DATA None SEVERITY Error LOG Always ACTION Reboot the system If the problem persists report the error to Technical Support Run with verbose mode on for more details Driver for Linux Troubleshooting Section Page 42 elx_mes0227 Node Authentication timeout DESCRIPTION The driver has lost track of what NPORTs are being authenticated DATA None SEVERITY Error LOG Always ACTION None required The driver should recover from this event elx_mes0228 CLEAR LA timeout DESCRIPTION The driver issued a CLEAR_LA that never completed DATA None SEVERITY Error LOG Always ACTION None required The driver should recover from this event elx_mes0231 RSCN timeout DESCRIPTION The driver has lost track of what NPORTs have RSCNs pending DATA 1 fe_ns_retry 2 lpfc_max_ns_retry SEVERITY Error LOG Always ACTION None required The driver should recover from this event elx_mes0232 Continue discovery with lt num_disc_nodes gt PLOGIs t
5. DATA 1 hba_state SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0113 An FLOGI ELS command lt elsCmd gt was received from DID lt did gt in Loop Mode DESCRIPTION While in Loop Mode an unknown or unsupported ELS command was received DATA None SEVERITY Error LOG Always ACTION Check device DID elx_mes0114 PLOGI chkparm OK DESCRIPTION Received a PLOGI from a remote NPORT and its Fibre Channel service parameters match this HBA Request can be accepted DATA 1 nlp_DID 2 nlp_state 3 nlp_flag 4 nlp_Rpi SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0115 Unknown ELS command lt elsCmd gt received from NPORT lt did gt DESCRIPTION Received an unsupported ELS command from a remote NPORT DATA None SEVERITY Error LOG Always ACTION Check remote NPORT for potential problem Driver for Linux Troubleshooting Section Page 36 elx_mes0116 Xmit ELS command lt elsCmd gt to remote NPORT lt did gt DESCRIPTION Xmit ELS command to remote NPORT DATA 1 icmd gt ulploTag 2 hba_state SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0117 Xmit ELS response lt elsCmd gt to remote NPORT lt did gt DESCRIPTION Xmit ELS response to remote NPORT DATA 1 icmd gt ulploTag 2 size SEVERITY Information LOG LOG_ELS verbose ACTION No action needed infor
6. 2 next 3 prev 4 postbufq_cnt SEVERITY Error LOG Always ACTION This error could indicate a software driver or firmware problem If the problem persists report these errors to Technical Support elx_mes0436 Adapter failed to init timeout status reg lt status gt DESCRIPTION The adapter failed during powerup diagnostics after it was reset DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support Driver for Linux Troubleshooting Section Page 51 elx_mes0437 Adapter failed to init chipset status reg lt status gt DESCRIPTION The adapter failed during powerup diagnostics after it was reset DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support elx_mes0438 Adapter failed to init chipset status reg lt status gt DESCRIPTION The adapter failed during powerup diagnostics after it was reset DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support elx_mes0439 Adapter failed to init moxCmd lt mbxCommand gt READ_REV mbxStatus lt mbxStatus gt DESCRIPTION Adapter initialization failed when issuing a READ_REV mailbox command DATA None SEVERITY Error LOG A
7. IOCB wait issue failed DESCRIPTION The Ipfc driver failed to issue an IOCB DATA 1 retval SEVERITY Information LOG LOG_SLI verbose ACTION None required elx_mes0334 Unknown IOCB command DESCRIPTION Received an unknown IOCB command completion DATA 1 type 2 ulpCommand 3 ulpStatus 4 ulploTag 5 ulpContext SEVERITY Error LOG Always ACTION This error could indicate a software driver or firmware problem If these problems persist report these errors to Technical Support elx_mes0335 Unknown IOCB command DESCRIPTION Received an unknown IOCB command completion DATA 1 ulpCommand 2 ulpStatus 3 ulploTag 4 ulpContext SEVERITY Error LOG Always ACTION This error could indicate a software driver or firmware problem If these problems persist report these errors to Technical Support elx_mes0336 Rsp Ring lt ringno gt error OCB DESCRIPTION An IOCB error has occurred on the specified ring DATA 1 ulpWord 0 2 ulpWord 1 3 ulpWord 2 4 ulpWord 3 5 ulpWord 4 6 ulpWord 5 7 irsp 6 8 irsp 7 SEVERITY Warning LOG LOG_SLI verbose ACTION If the problem persists check the targets If the targets are okay report the error to Technical Support elx_mes0337 Rsp Ring lt ringno gt error OCB DESCRIPTION An IOCB error has occurred on the specified ring DATA 1 ulpWord 0 2 ulpWord 1 3 ulpWord 2 4 ulpWord 3 5 ulpWord 4 6 ulpWord 5 7 irsp 6 8 irsp
8. Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0108 No retry ELS command lt elsCmd gt to remote NPORT lt did gt DESCRIPTION The driver decided not to retry the specific ELS command that failed DATA 1 retry SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0109 ACC to LOGO completes to NPort lt nlp_DID gt DESCRIPTION The driver received a LOGO from a remote NPort and successfully issued an ACC response DATA 1 nlp_flag 2 nlp_state 3 nlp_rpi SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Driver for Linux Troubleshooting Section Page 35 elx_mes0110 ELS response tag lt ulploTag gt completes DESCRIPTION The specific ELS response was completed by the firmware DATA 1 ulpStatus 2 ulpWord 4 3 nlp_DID 4 nlp_flag 5 nlp_state 6 nlp_rpi SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0111 Dropping received ELS cmd DESCRIPTION The driver decided to drop an ELS Response ring entry DATA 1 ulpStatus 2 ulpWord 4 3 ulpTimeout SEVERITY Error LOG Always ACTION This error could indicate a software driver or firmware problem If problems persist report these errors to Technical Support elx_mes0112 ELS command lt elsCmd gt received from NPORT lt did gt DESCRIPTION Received the specific ELS command from a remote NPort
9. SEVERITY Error LOG Always ACTION Write a value within the supported range Driver for Linux Troubleshooting Section Page 53 elx_mes0451 Enable interrupt handler failed DESCRIPTION The driver attempted to register the HBA interrupt service routine with the host operating system but failed DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or driver problem If the problem persists report the error to Technical Support elx_mes0453 Adapter failed to init moxCmd lt mbxCommand gt READ_CONFIG mbxStatus lt mbxStatus gt DESCRIPTION Adapter initialization failed when issuing a READ_CONFIG mailbox command DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support elx_mes0454 Adapter failed to init moxCmd lt mbxCommand gt INIT_LINK mbxStatus lt mbxStatus gt DESCRIPTION Adapter initialization failed when issuing an INIT_LINK mailbox command DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support elx_mes0455 Vital Product DESCRIPTION Vital product data VPD contained in the HBA flash DATA 1 vpd 0 2 vpd 1 3 vpd 2 4 vpd 3 SEVERITY Information LOG LOG_INIT verbose ACTION No action needed informational elx_mes0457 Adap
10. This script will fail if the vport is not created Note You must supply the physical port s host number WWPN and WWNN when using the mkvport sh script Note It is possible for a vport to be created successfully but be in failed state For example loop devices and NPIV are not supported on the same port simultaneously If you are running a loop topology and you create a vport the vport s link state will be off line The rmvport sh Script You can use the rmvport script to delete vports To see the usage information run the script with no parameters specified The rmvport sh script uses the following syntax rmvport sh lt Virtual Port s Host number gt Or rmvport sh lt Port Name gt lt Node Name gt For example gt rmvport sh 10000000c94ac63a 20010000c94ac63a would delete the vport with port name of 10000000c94ac63a and node name of 20010000c94ac63a This script will fail if the vport is not deleted and may take up to 30 seconds to complete Note You must un map un mount and flush I O to vport connected devices before deleting the vport The Isvport sh Script You can use the Isvport script to list the vports and physical ports that are present on the system Run the script with no parameters to display port information For example root curly scripts lsvport sh lpfcO host6 10000000c93a5b5e 20000000c93a5b5e LP10000 NPIV Not Supported lpfcl host7 10000000c93a5b5d 2000000
11. len 2 resid 3 underflow SEVERITY Information LOG LOG_FCP verbose ACTION None required Driver for Linux Troubleshooting Section Page 57 elx_mes0718 Unable to dma_map_ single request_buffer lt dma_error gt DESCRIPTION An error occurred while sending a command and the command will be retried DATA none SEVERITY Error LOG Always ACTION If the problem persists please report the error to Technical Support elx_mes0719 LUN Reset I O flush failure cnt lt cnt gt DESCRIPTION Timed out while waiting during a LUN reset DATA none SEVERITY Information LOG LOG_FCP verbose ACTION If other errors are also occurring please report this message to Technical Support elx_mes0720 FCP command lt cmnd 0 gt residual overrun error DESCRIPTION A residual overrun error has occurred while processing the specified FCP command DATA 1 request_bufflen 2 resid SEVERITY Warning LOG LOG_FCP verbose ACTION If the problem persists check the targets for errors elx_mes0729 FCP cmd lt cmnd gt failed lt target gt lt lun gt status lt status gt result lt result gt DESCRIPTION The specifed device failed an FCP command DATA 1 ulpContext 2 iotag SEVERITY Warning LOG LOG_FCP verbose ACTION Check the state of the target in question elx_mes0730 FCP command failed RSP DESCRIPTION The FCP command failed with a response error DATA 1 resp_info 2 scsi_status 3 Resid 4 Sns
12. rete modprobe CONi isinisisi ianiai isankan aain 11 Temporary Configuration Method cccceceeeeeeeeeeeeeeecneeeeeeeeeeeenenaeeeeeees 11 Persistent Configuration Method sssssssssssreesssssserrrrsssssrrrrrnnnsssssrrrnne 12 Temporary Driver Configuration by Read Write to sysfs cccceeeeeeeeeeeeees 12 Creating a New Ramdisk IMag ccceeeeeeeeeeeeeeeneeeeeeeeeeeecenneeeeeeeeeeteeenaaaes 13 For Installed Ipfc Driver Kits 2 2 ccceceeceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeteeeeeeeeeeeess 13 For Distribution In Box Iple DiVersi 13 Dynamically Adding LUNs and Targets cccccecceceeeeeeeeeeeeeeeeeeeeeeeeeeeeetetenes 13 Driver Parameters Reference Table ccccccccceceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 14 Using udev for Persistent NAMING cceeeeeeeeeeeeeeeeecteeeeeeeeeeeeeeeeeeeeeeeeeeeetees 18 Using udev to Discover Logical to Physical Mappings for sd Devices 18 Configuring the System to Boot From SAN Using Persistent Names 19 Using udev with st DeVICOS sca cicicschccansiacctancncectetctedesadenasdtatencecnatetetetenataeans 19 Further Information About Persistent Names ccccccccceceteeeeeeeeeeeeeeteees 21 Working with Virtual Ports Vports 0 aaa 21 Creating Deleting and Displaying VpPoOrts ceccceeeeeeeeeeeeeeeeeneeeeeeeeeeeeeeeaaees 21 Driver for Linux User Manual Page iii The mkvport sh Script ccc cece cece eee e eee e eee
13. ulpStatus 2 ulpWord 4 3 ulpTimeout 4 disc 5 num_disc_nodes SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Driver for Linux Troubleshooting Section Page 34 elx_mes0103 PRLI completes to NPort lt nlp_DID gt DESCRIPTION The HBA performed a PRLI into a remote NPort DATA 1 ulpStatus 2 ulpWord 4 3 ulpTimeout 4 num_disc_nodes SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0104 ADISC completes to NPort lt nlp_DID gt DESCRIPTION The HBA performed a ADISC into a remote NPort DATA 1 ulpStatus 2 ulpWord 4 3 ulpTimeout 4 disc 5 num_disc_nodes SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0105 LOGO completes to NPort lt nlp_DID gt DESCRIPTION The HBA performed a LOGO to a remote NPort DATA 1 ulpStatus 2 ulpWord 4 3 ulpTimeout 4 num_disc_nodes SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0106 ELS cmd tag lt ulploTag gt completes DESCRIPTION The specific ELS command was completed by the firmware DATA 1 ulpStatus 2 ulpWord 4 3 ulpTimeout SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0107 Retry ELS command lt elsCmd gt to remote NPORT lt did gt DESCRIPTION The driver is retrying the specific ELS command DATA 1 retry 2 delay SEVERITY
14. 7 SEVERITY Warning LOG LOG_SLI verbose ACTION If the problem persists check the targets If the targets are functioning properly report the error to Technical Support Driver for Linux Troubleshooting Section Page 50 elx_mes0338 Kill HBA DESCRIPTION The driver is sending a Kill Board mailbox command to the FW DATA 1 hba_state 2 sli_flag SEVERITY Informational LOG LOG_SLI verbose ACTION No action needed Informational Temperature Events 0340 0347 elx_mes0340 Adapter temperature is OK now DESCRIPTION Adapter temperature has reverted to normal range DATA Temperature in Celsius SEVERITY Error LOG LOG_TEMP verbose ACTION No action needed informational elx_mes0347 Adapter is very hot please take corrective action DESCRIPTION Adapter temperature is above normal range DATA Temperature in Celsius SEVERITY Error LOG LOG_TEMP verbose ACTION Shutdown and remove the HBA Contact customer support Initialization Events 0400 0499 elx_mes0405 Service Level Interface SLI 2 selected DESCRIPTION A CONFIG_PORT SLI2 mailbox command was issued DATA None SEVERITY Information LOG LOG_INIT verbose ACTION No action needed informational elx_mes0410 Cannot find virtual addr for mapped buf on ring lt ringno gt DESCRIPTION The driver cannot find the specified buffer in its mapping table Thus it cannot find the virtual address needed to access the data DATA 1 phys
15. Group Name 2 Stop HBAnyware 3 Stop Device Mapper Driver for Linux Troubleshooting Section Page 29 Table 6 General Driver Situations Continued Situation Resolution rmmod of Ipfc driver hangs and module reference count is 0 Due to a small race condition in the kernel it is possible for an rmmod command to hang Issue the rmmod w command If this does not help reboot the computer rmmod fails to unload driver due to Device or resource busy This message occurs when you attempt to remove the driver without first stopping the HBAnyware utility or the fcauthd daemon when the HBAnyware utility is installed and running or when FC disks connected to a LightPulse HBA are mounted Stop the HBAnyware utility before attempting to unload the driver The script is located in the usr sbin hbanyware directory Type stop_hbanyware Unmount any disks connected to the HBA Unload the driver Type rmmod Ipfcdfc Type rmmod Ipfc An Ispci will show recent Emulex HBAs as unknown This is because of the delay of getting new product ID s into the Linux development cycle None at this time Slow targets or extended link faults on the storage side may result in storage being marked off line by the mid layer and remaining off line not recovered when the link faults are corrected This version of the driver should eliminate this problem However should you experience off line device issues
16. Linux Distributions 4 Upgrading the Kernel or Applying a Distribution Service Pack or Update 5 Installing the Driver Kit into an Upgraded Kernel eeens 5 Booting From a Non Zero LUN Attached to an Emulex HBA 2 cceeeeeeeeeeeeeeees 6 Installing the Applications Kit 0 00 0 ll ll ld lll 6 Prerequisites cancun nnn ee 6 POCO CU Oai oaa E E 6 Utilities Directory Structure seeeeessseereseesssrrirrrtttssstirrnnentsssttnnnnrnnssseennnn 7 Installing the HBAnyware Utility with Web Launch 8 Pror gui S aaa CREET TERETE E ceeded dees 8 Procedu scnccreiieenee ended cccecnenmecdtocnnecererederaterececdceeecorieececeeds 8 Installing the HBAnyware Security Configurator ccceceeeeeeeeccteeeeeeeeeetaees 9 PYOPOQUISIOS 220 c cccecechcinatadisssadesesnsadisasdaasnasdedadededadesedetes deemenemencneneneeemenenetens 9 POCO CUI ccs oe cg eee eee eteeeee tees eeeeereeels 9 Uninstalling the Driver Kit cc cceeeee cece eee eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeteneas 9 Uninstalling the Applications Kit ll in ln ll i i lillies 10 Uninstalling the HBAnyware Security Configurator cccceeeeteeeeeneeeeeeees 10 Uninstalling HBAnyware with Web Launch ccccecceeeeeeeeeeeeeeeeeeeeeeeeeeteeeeees 10 Uninstalling HBAnyware eccccccccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeteeeenenas 10 CONTI GUN AUIONN anenai eaaa eaaa aaaea raini 11 Driver Configuration Methods Using modprobe and
17. data integrity of the I O between the HBA and the attached storage and can be ignored elx_mes0204 Devloss timeout on WWPN lt address gt NPort lt nip_ DID gt DESCRIPTION A remote NPort that was discovered by the driver disappeared for more than lpfc_devloss_tmo seconds DATA 1 nlp_flag 2 nlp_state 3 nlp_rpi SEVERITY Informational LOG LOG_DISCOVERY verbose ACTION If the device generating this message is not a target to which the HBA is connected this error will not affect the data integrity of the I O between the HBA and the attached storage and can be ignored elx_mes0205 Abort outstanding I O on NPort lt Fabric_DID gt DESCRIPTION All outstanding I Os are cleaned up on the specified remote NPort DATA 1 nlp_flag 2 nlp_state 3 nlp_rpi SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Driver for Linux Troubleshooting Section Page 39 elx_mes0206 Device discovery completion error DESCRIPTION This indicates that an uncorrectable error was encountered during device re discovery after a link up Fibre Channel devices will not be accessible if this message is displayed DATA None SEVERITY Error LOG Always ACTION Reboot the system If the problem persists report the error to Technical Support Run with verbose mode on for more details elx_mes0207 Device lt DID gt lt WWN gt sent invalid service parameters Ignoring device DESCRIPTION Invalid serv
18. driver as a module using the modprobe command and change one or more driver parameter values it is a temporary configuration These changes are considered temporary because they are valid for the current session only or until the driver is unloaded again Modprobe uses the modprobe conf file but parameters passed to it using the command line override parameters in the modprobe conf file Values can be expressed in hexadecimal or decimal notation Example of Temporary Configuration You want to temporarily set lun_queue_depth to 20 default is 30 for all host bus adapters in your system Load the driver with the following command modprobe lpfc lpfc_lun queue _depth 20 Driver for Linux Configuration Section Page 11 Persistent Configuration Method To make the driver parameters persistent across module loads and reboots modify the etc modprobe conf file If driver parameters are modified in etc modprobe conf the driver must be reloaded for the parameters to take effect Also a new ramdisk image is required if you want the changes to take effect in the next boot See Creating a New Ramdisk Image on page 13 to learn how The driver parameters are specified in etc modprobe conf via the options command For example the following sets the verbose flag options lpfc lpfc_ log verbose 0xffff If the same option is specified in both the etc modprobe conf and on the modprobe command line the option setting in the command line takes
19. e eee eee eee KARAKARA KAKAK ERAKKRKKKKKKK 22 The rmvport sh SCript 2 ccc cece cece eee e eee e eee e EE EE EEE EEE EEE EEE EE Ete EEEEEEEEEEEES 22 The lsvport sh SCript ccc cece cence eee anana eee EEE EEE EEE ARRANA REAR RANARRARA RARAN 22 The vport SySfS Tre 00 0 aaa aaa aaa aaa aaaaaee 23 Driver Version 8 2 0 x sysfs StrUCtUre ccccccccccccccccceceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeess 23 Vport sysfs Entries cccccceeeeeceeeeeeeeeeeeeeeeaaeeeeeeeeeeeeaaaaaeeeeeeeeeeaaaaneeeeeees 23 Vport Configuration LiMitS siivisccciiviscicsiececiiecieacviarsaacviacsnaaviarsearsiersiaaveacvvanveanned 25 DH CHAP Authentication and Configuration ccccceeeeeeeeeeeeeeeecneeeeeeeeetenaeeeeeees 26 Enabling Authentication ll nn ll nln li ll ii li lillies 26 The Ipfc_enable_auth Driver Paramete cccccccceeeeeeeeeeeeeeeeeateeeeeeees 27 The tcauthd DAMON sivcteccscacenttcaeedeciccdonainn deena nce i wnadaivaseneiia daeadeecaacnaalien 27 Authentication Configuration Parameters ccccecceeeeeeeeeeecnaeeeeeeeeeetenenaaeees 28 Setting Remote and Local PaSSwords ccccceeeeeeeeeeeeeeeccneeeeeeeteeeeenaaeeeeeees 28 TROUBDICSNOOUNG srssiccsesanssascctsaicecsassacannassstcannauenaamecasassscaasisiisieaccansatanenans 29 WWALPOGUIGHIONN Scct cc biccatanetecetctccc ataetenetenete ssgtenenctentactatactuqnetene ccaucsetaneceueeeauesauaecnenaeetes 29 Unusual Situations and their Resolutions ccce
20. gt DESCRIPTION An Authentication process was rejected then restarted and authentication requested again due to reason as displayed with explanation DATA 1 reason 2 explanation SEVERITY Error LOG LOG_SECURITY ACTION Software driver Error If this problem persists report errors to the Technical Support Elx_ msg1038 Authentication not required by the fabric Disabled DESCRIPTION For a given security configuration Authentication is disabled by the fabric as it not required DATA None SEVERITY Information LOG LOG_SECURITY ACTION Informational message only If you have questions please contact the Technical Support Driver for Linux Troubleshooting Section Page 65 Elx_msg1039 Not Expecting Reply rejecting State lt state gt DESCRIPTION An unanticipated reply was received during authentication and was subsequently rejected DATA 1 auth_state SEVERITY Error LOG LOG_SECURITY ACTION Software driver Error If this problem persists report errors to the Technical Support Elx_msg1040 Bad Reply trans_id rejecting Trans_id lt trans_id gt Expecting lt trans_id gt DESCRIPTION Unexpected transaction id was received during authentication and was subsequently rejected DATA 1 auth_state SEVERITY Error LOG LOG_SECURITY ACTION Software driver Error If this problem persists report errors to the Technical Support Elx_msg1041 Authentication Successful DESCRIPTION Authentication su
21. not in etc scsi_id config Below is another example for a different FC Tape Vendor Notice that the answer is similar with respect to the leading digit and the WWPN root localhost sbin scsi_id g s sys class scsi tape nst0 35005076300015101 Below is an example of a FC SCSI Tape device Notice that when the Emulex driver loads the SCSI midlayer discovers the SCSI tape devices as follows scsi scan INQUIRY to host 14 channel 0 id O lun 0 scsi unknown device type 12 Vendor ADIC Model SNC 4000 Rev 42d4 Type r RAID Attached scsi gene Attached scsi gene ANSI SCSI revision 03 ric sg5 at scsil4 channel 0 id 0 lun 0 type 12 scsi scan INQUIRY to host 14 channel 0 id O lun 1 Vendor ADIC Model Scalar 24 Rev 227A Type Medium Changer ANSI SCSI revision 02 ric sg6 at scsil4 channel 0 id 0 lun 1 type 8 scsi scan INQUIRY to host 14 channel 0 id O lun 2 Vendor IBM Model ULTRIUM TD2 Rev 38D0 Type Sequential Access ANSI SCSI revision 03 Attached scsi tape st0 at scsil4 channel 0 id 0 lun 2 st0 try direct i o yes alignment 512 B max page reachable by HBA 4503599627370495 Attached scsi generic sg7 at scsil4 channel 0 id 0 lun 2 scsi scan INQUIRY to host 14 channel 0 id 0 lun 3 Vendor IBM Model ULTRIUM TD2 Rev 38D0 Type Sequential Access ANSI SCSI revision 03 Attached scsi tape stl at scsil4 channel 0 id 0 lun 3 stl try direct i o yes alignment 512 B max page
22. precedence Temporary Driver Configuration by Read Write to sysfs Sysfs is a virtual filesystem that exposes the structure of the system It also includes interfaces to driver parameters through which the driver parameters can be viewed and modified Since these interfaces are available only after driver load only those parameters that can be modified dynamically can be changed However all driver parameters can be read through sysfs Note Sysfs changes only exist during driver load and are lost when the driver is unloaded or rebooted The sysfs filesystem is mounted and available as sys You must first identify the scsi_host which represents the HBA for which you wish to modify the driver parameters All scsi_hosts bound to the Ipfc driver can be viewed with the following command ls d sys bus pci drivers lpfc host Assuming you are interested in HBA scsi_host 7 you can list the driver parameters for this particular HBA as ls 1 sys class scsi_host host7 lpfc An example output is as follows r r r 1 root root 4096 Feb 28 17 03 sys class scsi_host host7 lpfc_ack0 rw r r 1 root root 4096 Feb 28 17 03 sys class scsi_host host7 lpfc_fcp_bind_method r r r 1 root root 4096 Feb 28 17 03 sys class scsi_host host7 lpfc_fcp_class rw r r 1 root root 4096 Feb 28 17 03 sys class scsi_host host7 lpfc_fdmi_on r r r 1 root root 4096 Feb 28 17 03 sys class scsi_host host7 lpfc_link_speed rw r r 1 root r
23. scsi_tape nst n RESULT 1IBM _ ULTRIUM TD2 1110133831 SYMLINK fc_lun_st n BUS Scsi RESULT 1IBM ULTRIUM TD2 1110133994 SYMLINK fc_lun_st n Create a new file named etc udev rules d 45 local rules and put the appropriate rule in it Then run udevtrigger to reload the udev rules And finally here is the output of the rule root localhost udevtrigger root localhost 1s al dev fc lrwxrwxrwx 1 root root 3 Apr 7 15 03 fc_lun_stO gt sto lrwxrwxrwx 1 root root 3 Apr 7 15 03 fc_lun_stl gt stl Further Information About Persistent Names Refer to the following references for more information on persistent naming http www kroah com linux talks ols_2003_udev_paper Reprint Kroah Hartman OLS2003 padf http www reactivated net udevrules php by Daniel Drake dsd http kernel org pub linux utils kernel hotplug udev_vs_devfs by Greg Kroah Hartman http linux dell com deviabel devlabel htm http www novell com documentation sles10 pdfdoc stor_evms stor_evms pdf Working with Virtual Ports vports Creating Deleting and Displaying vports Vports are created through sysfs entries that are presented in the physical port s sysfs directory The vport_create and vport_delete sysfs entries are discussed in the sysfs section but there are also three scripts for creating deleting and displaying vports The scripts reside in the usr sbin lpfc scripts directory and are part of the HBAnyware Applications kit When N
24. verbose ACTION No action needed informational elx_mes0308 Mbox cmd issue BUSY DESCRIPTION The driver attempted to issue a mailbox command while the mailbox was busy processing the previous command The processing of the new command will be deferred until the mailbox becomes available DATA 1 mbxCommand 2 hba_state 3 sli_flag 4 flag SEVERITY Information LOG LOG_MBOxX verbose LOG_SLI verbose ACTION No action needed informational elx_mes0309 Mailbox cmd lt mbxcommand gt issue DESCRIPTION The driver is in the process of issuing a mailbox command DATA 1 hba_state 2 sli_flag 3 flag SEVERITY Information LOG LOG_MBOxX verbose LOG_SLI verbose ACTION No action needed informational elx_mes0310 Mailbox command lt mbxcommand gt timeout DESCRIPTION A mailbox command was posted to the adapter and did not complete within 30 seconds DATA 1 hba_state 2 sli_flag 3 mbox_active SEVERITY Error LOG Always ACTION This error could indicate a software driver or firmware problem If no I O is going through the adapter reboot the system If the problem persists report the error to Technical Support elx_mes0311 Mailbox command lt mbxcommand gt cannot issue DESCRIPTION The driver is in the wrong state to issue the specified command DATA 1 hba_state 2 sli_flag 3 flag SEVERITY Information LOG LOG_MBOxX verbose LOG_SLI verbose ACTION No action needed informational Driver f
25. 0c93a5b5d LP10000 NPIV Not Supported lpfc2 host8 10000000c93cc8dd 20000000c93cc8dd LPe12000 NPIV Physical lpfc4 host10 10000000c94ac63a 20010000c94ac63a NPIV Virtual VPI 1 lpfc3 host9 10000000c93cc8dc 20000000c93cc8dc LPe12000 NPIV Physical root curly scripts For LPFCO and LPFC1 NPIV Not Supported means that this HBA firmware combination does not support the creation of vports For LPFC2 NPIV Physical refers to a physical port of this HBA For LPFC4 NPIV Virtual refers to a vport of this HBA Driver for Linux Configuration Section Page 22 The vport Sysfs Tree When a vport is created two new directories are created in the class tree sys class scsi_host hostyY sys class fc_host hostyY Creating a new vport also creates a new sysfs directory in the bus and devices tree root curly scripts ls sys bus pci drivers lpfc 0000 07 00 0 host8 fc_host host8 host10 power scsi_host host8 uevent root curly scripts ls sys bus pci drivers lpfc 0000 07 00 0 host8 host10 fc_host host10 power scsi_host host10 uevent Above host 8 is the physical port and host 10 is a virtual port that was created on host 8 Driver Version 8 2 0 x sysfs Structure For the 8 2 0 x driver the fc_vport directory does not exist yet so a link from the physical port to the vport is present in the fc_host s device directory root doc ls sys class fc_host host5 device fc_host host5 power scsi _host host5 host6 uevent
26. 2 6 driver _kit lt driver version gt 7 Execute the Ipfc install script with no options to install the new driver kit Type lpfc install 8 Reboot the system to complete re installation of the Emulex driver Driver for Linux Installation Section Page 5 EMULEX Booting From a Non Zero LUN Attached to an Emulex HBA This section describes how to configure SLES 10 to boot from an FC attached disk device other than dev sda This example uses dev sdb To boot from a non zero LUN attached to an Ipfc HBA Configure the Emulex HBA bootBIOS to boot from the desired LUN Start the standard SLES 10 SP1 installation At the Installation Settings screen after configuring the desired partitions select the Expert tab Select Booting to change the bootloader configuration The Boot Loader Settings window appears Select the Boot Loader Installation tab Oe he a In the section labeled Boot Loader Location select Custom Boot Partition then select the root partition or boot partition if you configured one from the dropdown box 7 Click the Boot Loader Options button The Boot Loader Options window appears Select the Write generic Boot Code to MBR checkbox 8 Click OK 9 Inthe Boot Loader Settings window Click Finish 10 Proceed with the installation 11 During the first boot after the installation use the GRUB command line to change all hd1 references to hd0 then continue the boot process 12 Edit the GRUB configurat
27. DATA 1 ulpContext 2 nlp_DID 3 nlp_flag 4 nlp_state 5 nip_rpi SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Driver for Linux Troubleshooting Section Page 38 elx_mes0132 Xmit RNID ACC response tag lt ulploTag gt DESCRIPTION A RNID ACC response for the specified IO tag has been sent DATA 1 ulpContext SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Link Discovery Events 0200 0299 elx_mes0200 CONFIG_LINK bad hba state lt hba_state gt DESCRIPTION A CONFIG_LINK mbox command completed and the driver was not in the right state DATA None SEVERITY Error LOG Always ACTION Software driver error If this problem persists report these errors to Technical Support elx_mes0202 Start Discovery hba state lt hba_state gt DESCRIPTION Device discovery rediscovery after FLOGI FAN or RSCN has started DATA 1 fe_flag 2 fc_plogi_cnt 3 fe_adisc_cnt SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational elx_mes0203 Devloss timeout on WWPN lt address gt NPort lt nip_ DID gt DESCRIPTION A remote NPort that was discovered by the driver disappeared for more than lpfc_devloss_tmo seconds DATA 1 nlp_flag 2 nlp_state 3 nlp_rpi SEVERITY Error LOG Always ACTION If the device generating this message is not a target to which the HBA is connected this error will not affect the
28. Dragonfly chip version 2 00 or greater use firmware version 3 93a0 e If your HBA has a Dragonfly chip below version 2 00 use firmware version 3 30a7 Refer to the LP8000 and LP8000DC Firmware Download page on the Emulex Web site to deter mine the Dragonfly chip version in use Note NPIV is supported on Emulex 4 Gb and 8 Gb HBAs that fully support SLI 3 Emulex enterprise class 5 digit HBA model number and Midrange class 4 digit HBA model number HBAs support SLI 3 Emulex 3 digit model number HBAs do not fully support SLI 3 and therefore do not support NPIV The LPFC 8 2 X driver supports all HBAs running SLI 2 but NPIV support is not available in SLI 2 mode For SLI 3 supported HBAs use the latest recommended firmware for NPIV support Things to Know Before You Download e You must uninstall any previous Ipfc driver kits and or Application Helper Modules that were installed from the Emulex CD or downloaded from the Emulex Web site i e not part of a distribution before installing this driver kit Known Issues e Some Web browsers attempt to continually reload the HBAnyware utility s online help rendering it unusable In this case disable the Web browser s JavaScript capability Refer to the Web browser s documentation for instructions e Emulex s HBAnyware configuration utility provides support for LightPulse adapters that are reprogrammed with WWPNs outside the typical Emulex range such as HP s upcoming Virtua
29. ION The fabric does not support FDMI check fabric configuration Driver for Linux Troubleshooting Section Page 41 elx_mes0221 FAN timeout DESCRIPTION A link up event was received without the login bit set so the driver waits E_D_TOV for the Fabric to send a FAN If no FAN if received a FLOGI will be sent after the timeout DATA None SEVERITY Warning LOG LOG_DISCOVERY verbose ACTION None required The driver recovers from this condition by issuing a FLOGI to the fabric elx_mes0222 Initial FLOG FDISKI timeout DESCRIPTION The driver sent the initial FLOGI or FDISK to the fabric and never got a response back DATA None SEVERITY Error LOG Always ACTION Check Fabric configuration The driver recovers from this and continues with device discovery elx_mes0223 Timeout while waiting for NameServer login DESCRIPTION Our login request to the NameServer was not acknowledged within RATOV DATA None SEVERITY Error LOG Always ACTION Check the fabric configuration The driver recovers from this and continues with device discovery elx_mes0224 NameServer Query timeout DESCRIPTION Node authentication timeout node Discovery timeout A NameServer Query to the Fabric or discovery of reported remote NPorts is not acknowledged within R_A_TOV DATA 1 fe_ns_retry 2 fe_max_ns_retry SEVERITY Error LOG Always ACTION Check Fabric configuration The driver recovers from this and continues with device discovery
30. ITY Error LOG LOG_VPORT verbose ACTION No Action The driver can not create any more Vports elx_mes1810 Create VPORT failed Cannot get instance number DESCRIPTION The driver failed to allocate resources for an adapter and could not assign an instance number DATA None SEVERITY Error LOG LOG_VPORT verbose ACTION Software driver error If this problem persists report these errors to Technical Support Driver for Linux Troubleshooting Section Page 71 elx_mes1811 Create VPORT failed vpi x lt vpi gt DESCRIPTION The driver failed to create a port and had to eliminate all its resources DATA vpi SEVERITY Error LOG LOG_VPORT verbose ACTION Software driver error If this problem persists report these errors to Technical Support elx_mes1812 vport_delete failed Cannot delete physical host DESCRIPTION An attempt to delete a port failed because it was to delete a physical port and not a virtual port Only vports on physical ports can be deleted on an NPIV system DATA None SEVERITY Error LOG LOG_VPORT verbose ACTION Software driver error If this problem persists report these errors to Technical Support elx_mes1813 Create VPORT failed Cannot get sparam DESCRIPTION The port could not be created because it could not be initialized possibly due to unavailable resources DATA None SEVERITY Error LOG LOG_VPORT verbose ACTION Software driver error If this problem persists report these error
31. Len 5 RspLen 6 rspinfo3 SEVERITY Warning LOG LOG_FCP verbose ACTION Check the state of the target in question elx_mes0734 FCP read check error DESCRIPTION The issued FCP command returned a read check error DATA 1 fepDI 2 rspResld 3 fcpi_parm 4 cmd 0 SEVERITY Warning LOG LOG_FCP verbose ACTION Check the state of the target in question elx_mes0735 FCP Read Check Error and Underrun Data DESCRIPTION HBA reported under run from storage array DATA 1 vpi 2 fcpDI 3 res_id 4 fcpi_parm SEVERITY Warning LOG LOG_FCP_ERROR verbose ACTION No action needed informational Driver for Linux Troubleshooting Section Page 58 elx_mes0748 Abort handler timed out waiting for abort to complete ret lt status gt D lt target id gt LUN lt lun id gt DESCRIPTION The abort handler timed out waiting for abort to complete DATA None SEVERITY Error LOG Always ACTION None required elx_mes0749 SCSI layer issued abort device DESCRIPTION The SCSI layer aborted a device DATA 1 ret 2 id 3 lun 4 snum SEVERITY Warning LOG LOG_FCP verbose ACTION None required Node Table Events 0900 0999 elx_mes0900 Cleanup node for NPort lt nlp_DID gt DESCRIPTION The driver node table entry for a remote NPort was removed DATA 1 nlp_flag 2 nlp_state 3 nlp_rpi SEVERITY Information LOG LOG_NODE verbose ACTION None required elx_mes0901 FIND node DID reglogin DESCRIPTI
32. MD5 and SHA 1 hash functions and supports the following DH groups Null 1024 1280 1536 and 2048 Note This version of the driver supports for N Port to F Port authentication only and does not support N Port to N Port authentication Note If you wish to use DH CHAP Authentication you must install the Applications kit The Applications kit includes the fcauthd daemon software See Installing the Applications Kit on page 6 for instructions Enabling Authentication Enabling authentication is a three step process To enable authentication The fcauthd daemon must be running The lpfc_enable_auth module parameter must be set to enabled Note You can also enable authentication using the HBAnyware 3 4 configuration utility Refer the the HBAnyware 3 4 User Manual for more information Configure an HBA port to initiate requests for authentication respond to requests for authentication or both Driver for Linux Configuration Section Page 26 The Ipfc_enable_auth Driver Parameter Use the Ipfc_enable_auth driver parameter to enable or disable driver authentication support The Ipfc_enable_auth driver parameter can be set using the modprobe command or by manually editing etc modprobe conf and creating a new ramdisk Setting Ipfc_enable_auth does not mean a port will initiate authentication requests or process requests for authentication it simply enables authentication support in the driver You can als
33. ON The driver is searching for a node table entry on the binding list based on DID DATA 1 ndlp 2 nlp_DID 3 nlp_flag 4 data1 SEVERITY Information LOG LOG_NODE verbose ACTION None required elx_mes0902 FIND node DID prli DESCRIPTION The driver is searching for a node table entry on the binding list based on DID DATA 1 ndlp 2 nip_DID 3 nlp_flag 4 data1 SEVERITY Information LOG LOG_NODE verbose ACTION None required elx_mes0903 FIND node DID npr DESCRIPTION The driver is searching for a node table entry on the binding list based on DID DATA 1 ndlp 2 nlp_DID 3 nlp_flag 4 data1 SEVERITY Information LOG LOG_NODE verbose ACTION None required Driver for Linux Troubleshooting Section Page 59 elx_mes0904 Add NPort lt did gt to lt list gt list DESCRIPTION The driver is putting the node table entry on the specified list DATA 1 nlp_flag SEVERITY Information LOG LOG_NODE verbose ACTION None required elx_mes0905 FIND node DID unused DESCRIPTION The driver is searching for a node table entry on the binding list based on DID DATA 1 ndlp 2 nip_DID 3 nlp_flag 4 data1 SEVERITY Information LOG LOG_NODE verbose ACTION None required elx_mes0908 FIND node DID plogi DESCRIPTION The driver is searching for a node table entry on the plogi list based on DID DATA 1 ndlp 2 nip_DID 3 nlp_flag 4 data1 SEVERITY Information LOG LOG_NODE ve
34. PIV is enabled and vports are configured it may take longer for the HBA to finish discovery in some cases due to the fact that each virtual port must perform discovery independently As more vports are configured the amount of time that the driver and HBA take to finish discovery of remote ports on the SAN will increase To compensate for this extended amount of time taken in discovery it is recommended that the user set the lpfc_devloss_tmo parameter to 60 when npiv is enabled Note Ensure you are using the latest recommended firmware for Vport functionality Check the Emulex Web site for the latest firmware Note Loop devices and NPIV are not supported on the same port simultaneously If you are running a loop topology and you create a vport the vport s link state will be off line Note You can only create virtual ports on 4G and 8G HBAs You cannot create virtual ports on 1G and 2G HBAs Driver for Linux Configuration Section Page 21 The mkvport sh Script You can use the mkvport script to create vports To see the usage information run the script with no parameters specified The mkvport sh script uses the following syntax mkvport sh lt Physical Port s Host number gt lt Port Name gt lt Node Name gt For example gt mkvport sh host7 10000000c94ac63a 20010000c94ac63a would create a vport with port name of 10000000c94ac63a and a node name of 20010000c94ac63a on the physical port with scsi_host name host7
35. Support for further information Elx_msg1005 AUTHENTICATION_FAILURE Noport lt port gt DESCRIPTION The system detected DH CHAP authentication failure on a port DATA nlp_DID SEVERITY Error LOG LOG_SECURITY ACTION Verify authentication settings and keys on local and remote port Elx_msg1006 Bad Name tag in auth message lt message gt DESCRIPTION DH CHAP Authentication process failed when invalid tag was detected DATA message SEVERITY Error LOG LOG_SECURITY ACTION Software driver Error If this problem persists report errors to the Technical Support Elx_msg1007 Bad Name length in auth message lt message gt DESCRIPTION DH CHAP Authentication process failed when invalid name was detected DATA message SEVERITY Error LOG LOG_SECURITY ACTION Software driver Error If this problem persists report errors to the Technical Support Elx_msg1008 Bad Number of Protocols lt message gt DESCRIPTION DH CHAP Authentication process failed due to unexpected protocol number DATA message SEVERITY Error LOG LOG_SECURITY ACTION Software driver Error If this problem persists report errors to the Technical Support Elx_msg1009 Bad param type lt message gt DESCRIPTION DH CHAP Authentication process failed when invalid protocol was detected DATA message SEVERITY Error LOG LOG_SECURITY ACTION Software driver Error If this problem persists report errors to the Technical Support Driver for Li
36. X EMULEX Emulex Driver for Linux Version 8 2 User Manual Last updated May 15 2008 Critical Connectivity Solutions Copyright 2008 Emulex All rights reserved worldwide No part of this document may be reproduced by any means nor translated to any electronic medium without the written consent of Emulex Information furnished by Emulex is believed to be accurate and reliable However no responsibility is assumed by Emulex for its use or for any infringements of patents or other rights of third parties which may result from its use No license is granted by implication or otherwise under any patent or patent rights of Emulex Emulex AutoPilot Installer BlockGuard cLAN FabricStream FibreSpy Giganet HBAnyware InSpeed IntraLink LightPulse MultiPulse SAN Insite SBOD and Vixel are registered trademarks and AutoPilot Manager Critical Connectivity Solutions EZPilot SLI and VMPilot are trademarks of Emulex All other brand or product names referenced herein are trademarks or registered trademarks of their respective companies or organizations Emulex provides this manual as is without any warranty of any kind either expressed or implied including but not limited to the implied warranties of merchantability or fitness for a particular purpose Emulex may make improvements and changes to the product described in this manual at any time and without any notice Emulex assumes no responsibility for its use nor for any infringemen
37. and installing the JRE The HBAnyware utility must be installed before installing HBAnyware with Web Launch Procedure To install HBAnyware with Web Launch Log on as root Navigate to the HBAnyware directory Type cd usr sbin hbanyware Run the install script Type wsinstall When prompted enter the Web server s document root directory For example srv www htdocs You are provided with the IP address of the host and asked if that is the IP address that is being used by your Web server Answer Y or N as appropriate If you answer N you are prompted for the IP address you wish to use You are asked if your web server listening on the normal default HTTP port 80 Answer Y or N as appropriate If you answer N you are prompted for the port you wish to use You are notified the installation of the HBAnyware Web Launch package has completed Driver for Linux Installation Section Page 8 Installing the HBAnyware Security Configurator Follow these instructions to install the HBAnyware Security Configurator on your system The install script is located in the usr sbin nbanyware directory Prerequisites The Ipfc driver must be installed The HBAnyware utility must be installed on all participating systems Procedure To install the HBAnyware Security Configurator utility Log on as root 2 Change use the cd command to the directory to which you copied the tar file See Installing the Appli
38. ardware problem Report these errors to Technical Support elx_mes0304 Stray mailbox interrupt moxCommand lt mbxcommand gt mbxStatus lt mbxstatus gt DESCRIPTION Received a mailbox completion interrupt and there are no outstanding mailbox commands DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support elx_mes0305 Mbox cmd cmpl error RETRYing DESCRIPTION A mailbox command completed with an error status that causes the driver to reissue the mailbox command DATA 1 mbxCommand 2 mbxStatus 3 un varWords 0 4 hba_state SEVERITY Information LOG LOG_MBOxX verbose LOG_SLI verbose ACTION No action needed informational Driver for Linux Troubleshooting Section Page 46 elx_mes0306 CONFIG_LINK mbxStatus error lt mbxStatus gt HBA state lt hba_state gt DESCRIPTION The driver issued a CONFIG_LINK mbox command to the HBA that failed DATA None SEVERITY Error LOG Always ACTION This error could indicate a firmware or hardware problem Report these errors to Technical Support elx_mes0307 Mailbox cmd lt mbxCommand gt Cmpl lt mbox_cmpl gt DESCRIPTION A mailbox command completed DATA 1 pmbox 2 varWords 0 3 varWords 1 4 varWords 2 5 varWords 3 6 varWords 4 7 varWords 5 8 varWords 6 9 varWords 7 SEVERITY Information LOG LOG_MBOxX verbose LOG_SLI
39. ation Section Page 4 Upgrading the Kernel or Applying a Distribution Service Pack or Update You can install the driver kit into an upgraded kernel The installation of an update or service pack generally involves updating the kernel Note Some distribution service packs or updates contain an Emulex driver If the driver version contained in the distribution or service pack is the same version or newer than the currently installed driver kit re installation of the driver kit may not be necessary Note The Ipfc install script does not support custom kernels For example kernels with Version_Release strings that do not match those of the original distribution kernel Note Follow these steps before installing a new update CD to a distribution or applying a service pack to a distribution Maintenance and errata kernels are supported Installing the Driver Kit into an Upgraded Kernel To install the driver kit into an upgraded kernel 1 Execute the Ipfc install script with the uninstall option Type usr srce lpfc install uninstall 2 Upgrade the kernel and or distribution 3 Reboot the system with the new kernel Download the driver kit from the Emulex Web site or copy it to the system from the installation CD 5 Logon as root to a terminal and unpack the tarball with the following command tar xzf lpfc_2 6 driver_kit lt driver version gt tar gz 6 Change to the directory that is extracted ed lpfc_
40. cations Kit on page 6 step 2 for reference 3 Run the install script with the ssc parameter specified Type install ssc Uninstalling the Driver Kit Note Driver parameter changes made using the HBAnyware utility or etc modprobe conf persist if the driver is uninstalled To return to the default settings you must modify the settings in etc modprobe conf Note You must run the uninstall script that shipped with the version of the driver kit you want to remove This section describes how to uninstall a previous version of the Emulex 8 x driver for Linux The uninstall procedure automatically restores the archived Ipfc driver To uninstall the Ipfc driver Log on as root 2 If possible exit all applications that use Fibre Channel attached drives then unmount the drives If you cannot exit all applications that use Fibre Channel attached drives the uninstall will work properly but you must reboot after the uninstallation is complete 3 Stop the HBAnyware utility Type cd usr sbin hbanyware stop_hbanyware Uninstall the Applications Kit See page 10 for instructions Copy the Ipfc install script to the temporary directory For example cp usr src lpfc lpfc install tmp 6 Execute the Ipfc install script with the uninstall option Type tmp lpfc install uninstall Driver for Linux Installation Section Page 9 Uninstalling the Applications Kit Follow these instructions to unin
41. cceeded DATA None SEVERITY Information LOG LOG_SECURITY ACTION Informational message only If you have questions please contact the Technical Support Elx_msg1042 Re Authentication Successful DESCRIPTION Re Authentication succeeded DATA None SEVERITY Information LOG LOG_SECURITY ACTION Informational message only If you have questions please contact the Technical Support Elx_msg1046 Authentication Successful DESCRIPTION Authentication succeeded DATA None SEVERITY Information LOG LOG_SECURITY ACTION Informational message only If you have questions please contact the Technical Support Elx_msg1047 Re Authentication Successful DESCRIPTION Re Authentication succeeded DATA None SEVERITY Information LOG LOG_SECURITY ACTION Informational message only If you have questions please contact the Technical Support Driver for Linux Troubleshooting Section Page 66 Elx_ msg1049 Authentication is enabled but authentication service is not running DESCRIPTION Discovery failed because DH CHAP Authentication was enabled while no authentication service was established DATA None SEVERITY Error LOG LOG_SECURITY ACTION Start the authentication daemon fcauthd Elx_ msg1050 Authentication mode is disabled but is required by the fabric DESCRIPTION Discovery failed because the switch fabric required authentication but authentication was not configured or the authentication mode for this p
42. ceeeeeeeeeeeeeeeeeeeceeeeeeeeeeeeesaeeees 29 General Situations cc ccceeessssssseeeseesseeseeecssssssaaaaeaaaaaaaaaaaaaaaaaaaaaaeeeeeeeeeeeeeeess 29 Ipfe LOG MESSAGES wiiecsicccticedecedeendecelenedaes aaa ai iaaiiai aiaia 33 INtrOGUCTON 00 eeeeee cece neeeeeeeee cece eaaaeeeeeeeeeeeeaaaaaeaeeeeeeeeaaaaaaeeeeeeeeesaaaaaeeeeeeeeeeeaaaeees 33 Message Log Exarmple cccccccccccccceeeeceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeteness 34 ELS Events 0100 0199 0 eeeeeccceeeeee eee eeeccee eee e eee teeecaaaeeeeeeeeteeeeaaeeeeeeeeteeeee 34 Link Discovery Events 0200 0299 00 0 eeeeeseeeeeeeeeeeeeeeeeeaeeaaaaaaaaaaaaaaaaaaaaaees 39 Mailbox Events 0300 0339 ccccccceccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeteeeas 45 Temperature Events 0340 0347 000 li li i iii 51 Initialization Events 0400 0499 eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 51 FARF Events 0600 0699 ccecccccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeas 55 FCP Traffic History 0700 0799 ceeeeeecceeeeeeeeeeeeeeceaeeeeeeeeeetecccaaeeeeeeeeeteeaes 55 Node Table Events 0900 0999 il i i ii iii 59 Security Events 1000 1099 cee eeeeecceeeeeeeeeeeceeee eee eeeeeeecaaeeeeeeeeeeeecnaeeeeeees 61 Miscellaneous Events 1200 1299 000 i eee 68 Link Events 1300 1399 02 cece cece eee e eee e eee e eee eeeeeeeeeeeeeeeeeeeeeeeeeeeeetes 68 IOCTL Events 1600 1699 20 0 ceccceee et
43. cript will attempt to install the driver into a ramdisk that follows the naming scheme used by Red Hat or SLES kernels e The SLES naming scheme for I A64 ramdisk images is boot efi efi suse initrd e The SLES naming scheme for ramdisk images on all other architectures is boot initrd If a custom built kernel has a ramdisk image that does not follow the appropriate naming scheme the name of the image can be changed using the following procedure 1 Change the name of the ramdisk image to match the SLES naming scheme 2 Update any file links to the ramdisk image 3 Edit the boot loader configuration file i e etc lilo conf etc yaboot conf boot grub grub conf boot grub menu Ist find any references to the old ramdisk image name and replace them with the new name 4 Reboot the system to verify the changes 5 Install the Emulex Ipfc Linux driver kit The Linux SCSI subsystem only sees 8 Some SCSI drivers will not scan past 8 LUNs when the target LUNs when more are present reports as a SCSI 2 device Force SCSI bus scan with usr sbin lpfc lun_scan SuSE supplies bin rescan scsi bus sh which can be changed to scan everything Cannot See Multiple Zones from the Provide a physical Fibre Channel connection into each of the Management Server Cannot see multiple zones For each zone you want to see connect an Emulex zones on the same screen of my HBAnyware utility enabled port into that zone Use Out of Band
44. cs when booted with a failed HBA installed Remove the failed HBA and reboot Ipfc driver unload on SLES 10 causes messages like the following to be logged in the system log umount dev disk bypath pci 0000 02 04 0 scsi 0 0 1 0 not mounted These messages are normal output from the SLES 10 hotplug scripts and can be safely ignored Driver for Linux Troubleshooting Section Page 30 Table 6 General Driver Situations Continued Situation Resolution Driver Install Fails The Ipfc install script fails to install the driver The install script may fail for the following reasons A previous version of the driver is installed Run the Ipfc install uninstall script and then try to install the driver e The current driver is already installed e The kernel source does not match the standard kernel name or you are running a custom kernel e Use rpm e Ipfcdriver and e hbanyware and install the new kits No module Ipfc found for kernel error message When upgrading the kernel rom generates the following error No module Ipfc found for kernel KERNELVERSION A recently upgraded kernel cannot find the ramdisk After upgrading the kernel the kernel cannot find the ramdisk which halts or panics the system The driver is not loaded after a system reboot after upgrading the kernel These three situations may be resolved by upgrading the kernel There are two ways to install the driv
45. ction Page 33 Table 7 Message Log Table Continued LOG Message From To Verbose Verbose Description Verbose Mask i ners Bit Definition LOG_VPORT 1800 1832 0x4000 NPIV events LOG_ALL_MSG 0100 1699 Oxffff Log all messages Message Log Example The following is an example of a LOG message Jul 2 04 23 34 daffy kernel lpfc 0000 03 06 0 0 1305 Link Down Event x2f2 received Data x2f2 x20 x110 In the above LOG message e Ipfc 0000 03 06 0 identifies the identifies the pci location of the particular Ipfc hw port e 0 identifies Emulex HBAO e 1305 identifies the LOG message number Note If the word Data is present in a LOG message any information to the right of Data is intended for Emulex technical support engineering use only ELS Events 0100 0199 elx_mes0100 FLOGI failure DESCRIPTION An ELS FLOGI command that was sent to the fabric failed DATA 1 ulpStatus 2 ulpWord 4 3 ulpTimeout SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0101 FLOGI completes successfully DESCRIPTION An ELS FLOGI command that was sent to the fabric succeeded DATA 1 ulpWord 4 2 e_d_tov 3 r_a_tov 4 edtovResolution SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0102 PLOGI completes to NPort lt nlp_DID gt DESCRIPTION The HBA performed a PLOGI into a remote NPort DATA 1
46. d 3 digit adapter We suggest you upgrade to a higher end adapter elx_mes0319 READ_SPARAM mbxStatus error lt mbxStatus gt hba state lt hba_state gt DESCRIPTION The driver issued a READ_ SPARAM mbox command to the HBA that failed DATA None SEVERITY Error LOG Always ACTION This error could indicate a firmware or hardware problem Report these errors to Technical Support elx_mes0320 CLEAR_LA mbxStatus error lt mbxStatus gt hba state lt hba_state gt DESCRIPTION The driver issued a CLEAR_LA mbox command to the HBA that failed DATA None SEVERITY Error LOG Always ACTION This error could indicate a firmware or hardware problem Report these errors to Technical Support Driver for Linux Troubleshooting Section Page 48 elx_mes0321 Unknown IOCB command DESCRIPTION Received an unknown IOCB command completion DATA 1 type 2 ulpCommand 3 ulpStatus 4 ulploTag 5 ulpContext SEVERITY Error LOG Always ACTION This error could indicate a software driver or firmware problem If these problems persist report these errors to Technical Support elx_mes0322 Ring lt ringno gt handler unexpected completion loTag lt loTag gt DESCRIPTION The driver could not find a matching command for the completion received on the specified ring DATA 1 ulpStatus 2 ulpWord 4 3 ulpCommand 4 ulpContext SEVERITY Warning LOG LOG_SLI verbose ACTION This error could indicate a software driver or firmwar
47. d command to the directory to which you copied the tar file during installation 3 Uninstall any previously installed versions Type uninstall Driver for Linux Installation Section Page 10 Configuration You can configure the driver by Setting module parameters using modprobe and etc modprobe conf e Using the sysfs interface for parameters that can be changed after loading the driver e Using the HBAnyware configuration utility See the HBAnyware 3 4 User Manual for more information Note Driver parameter changes made using modprobe conf or the HBAnyware utility persist if the driver is uninstalled To return to the default settings you must modify the settings in modprobe conf Note The Linux 2 6 kernel only supports setting the lpfc_log_verbose lpfc_devloss_tmo and Ipfc_use_adisc driver parameters for individual HBAs Other driver parameters must be applied to all HBAs contained in the host See the Driver Parameters Reference Table on page 14 for a complete list of driver parameters Driver Configuration Methods Using modprobe and etc modprobe conf The following sections describe how to set driver parameters using the modprobe command and by manually editing etc modprobe conf Note Emulex recommends using the HBAnyware utility or the hbacmd utility to change parameters See the HBAnyware User Manual for more information Temporary Configuration Method When you manually load the
48. d these limits are unsupported Configuration limits e All I O to devices accessed through a vport must be stopped and all file systems must be unmounted before the vport is deleted e Delete all vports created from each physical port before unloading the driver for those physical ports e For enterprise class HBAs the maximum number of virtual ports configurable on a physical port is 64 The hardware will allow more than 64 vports to be created but the driver has only been qualified at 64 For mid range HBAs the maximum number of vports configurable on a physical port is 16 e The maximum number of LUNs supported on each driver port is 256 e The maximum number of targets supported for each driver port is 255 Driver for Linux Configuration Section Page 25 e The maximum number of driver ports in one zone is 64 This limit is based on the system s ability to recover from link events within the time constraints of the default timers The use cases of NPIV that involve virtual server environment include associating a virtual port with a virtual machine and placing the virtual machine in its own zone This will result in one virtual port per zone In the case of load balanced environments this can increase typically to two virtual ports per virtual machine to a practical limit of something far less than 50 In the NPIV cases not related to virtual server environments zoning will typically be initiator zoning again resulti
49. driver connects directly to the fcauthd daemon To unload the driver you must first stop the fcauthd daemon This will close the netlink connection and allow the LPFC driver to unload The fcauthd daemon can be stopped using etc init d fcauthd stop or usr sbin hoanyware stop_hbanyware which will shutdown both the fcauthd daemon and the HBAnyware utility fcauthd Daemon Parameters The fcauth daemon supports the following parameters e start To start the fcauthd daemon pass the start command to the fcauthd script This command loads the daemon into memory opens a netlink for the driver to connect to and reads the authentication configuration database into memory for use by the LPFC driver e stop To stop the fcauthd daemon pass the stop command to the fcauthd script This command takes down the netlink between the fcauthd and the Ipfc driver and stop the feauthd daemon e reload The reload command reloads the authentication configuration database into memory This is done whenever the database is changed by another application HBAnyware or by the user If the database is changed the new configuration information is not used until the feauthd daemon reloads the database e status This command is used to display the current status of the fcauthd The status should be either running or stopped e restart The restart command performs a stop and then a start condrestart The conditional restart command checks the sta
50. e 73 elx_mes1824 NPIV enabled Override lpfc_sli_mode parameter lt mode gt to auto 0 DESCRIPTION The lpfc_enable_npiv and Ipfc_sli_mode driver parameter settings conflict The HBA must be configured for SLI 3 mode to support NPIV DATA 1 lpfc_sli_mode SEVERITY Error LOG LOG_VPORT verbose ACTION This is an informational message that indicates that the lpfc_enable_npiv and Ipfc_sli_mod parameter settings are not compatible Resolve the parameter conflict by setting the SLI mode to 0 or 3 or if SLI 2 mode is required then disable NPIV elx_mes1825 Vport Created DESCRIPTION This message is displayed to indicate that a port was created in the system It is displayed at this level to ensure it is always appears at all log levels DATA None SEVERITY Error LOG LOG_VPORT verbose ACTION No action informational elx_mes1826 Vport Disabled DESCRIPTION The port had to be disabled in the system DATA None SEVERITY Error LOG LOG_VPORT verbose ACTION No action informational elx_mes1827 Vport Enabled DESCRIPTION The port had to be enabled after possible recovery from some errors DATA None SEVERITY Error LOG LOG_VPORT verbose ACTION No action informational elx_mes1828 Vport Deleted DESCRIPTION A Vport was deleted DATA None SEVERITY Error LOG LOG_VPORT verbose ACTION No action informational elx_mes1829 CT command failed to delete objects on fabric DESCRIPTION A command is
51. e problem If problems persist report these errors to Technical Support elx_mes0323 Unknown Mailbox command lt mbxCommand gt Cmpl DESCRIPTION A unknown mailbox command completed DATA None SEVERITY Error LOG Always ACTION This error could indicate a software driver firmware or hardware problem Report these errors to Technical Support elx_mes0324 Config port initialization error moxCmd lt mbxCommand gt READ_NVPARM mbxStatus lt mbxStatus gt DESCRIPTION A read nvparams mailbox command failed during port configuration DATA None SEVERITY Error LOG Always ACTION This error could indicate a software driver firmware or hardware problem Report these errors to Technical Support elx_mes0325 Reset HBA DESCRIPTION An HBA has been reset DATA 1 hba_state 2 sli_flag SEVERITY Information LOG LOG_SLI verbose ACTION No action needed informational elx_mes0330 IOCB wake NOT set DESCRIPTION The completion handler associated with the IOCB was never called DATA 1 timeout 2 timeleft jiffies SEVERITY Error LOG Always ACTION This error could indicate a software driver firmware or hardware problem If the problem persists report the error to Technical Support Driver for Linux Troubleshooting Section Page 49 elx_mes0331 IOCB wake signaled DESCRIPTION The IOCB completed successfully DATA None SEVERITY Information LOG LOG_SLI verbose ACTION None required elx_mes0332
52. eauth_interval lt gt DESCRIPTION Re Authentication succeeded DATA 1 local_wwpn 2 remote_wwpn 3 auth_mode 4 hash_len 5 hash_priority 6 bidirectional 7 dh_group_len 8 dh_group_priority 9 reauth_interval SEVERITY Information LOG LOG_SECURITY ACTION Informational message only If you have questions please contact the Technical Support Elx_msg1028 Start Authentication No buffers DESCRIPTION The authentication failed because some memory resources were not allocated DATA None SEVERITY Error LOG LOG_SECURITY ACTION Software driver Error If this problem persists report errors to the Technical Support Elx_msg1029 Reauthentication Failure DESCRIPTION The driver encountered errors and there was a failure to re authenticate DATA None SEVERITY Error LOG LOG_SECURITY ACTION Software driver Error If this problem persists report errors to the Technical Support Elx_msg 1031 Start Authentication Get config failed DESCRIPTION The authentication failed due to some error during port configuration DATA None SEVERITY Error LOG LOG_SECURITY ACTION Software driver Error If this problem persists report errors to the Technical Support Elx_msg1032 Start Authentication get config timed out DESCRIPTION The node authentication was aborted because waiting for port configuration to complete timed out DATA None SEVERITY Error LOG LOG_SECURITY ACTION Software driver Error If th
53. ected a condition in which it had to re initialize the link DATA 1 status 2 status1 3 status2 SEVERITY Information LOG LOG_LINK_EVENT verbose ACTION If numerous link events are occurring check the physical connections to the Fibre Channel network elx_mes1302 Invalid speed for this board Reset link speed to auto lt cfg_link_speed gt DESCRIPTION The driver is reinitializing the link speed to auto detect DATA None SEVERITY Warning LOG LOG_LINK_EVENT verbose ACTION None required Driver for Linux Troubleshooting Section Page 68 elx_mes1303 Link Up Event lt eventTag gt received DESCRIPTION A link up event was received It is also possible for multiple link events to be received together DATA 1 fc_eventTag 2 granted_AL_PA 3 UlnkSpeed 4 alpa_mapj 0 Detail If link events received log 1 last event number received 2 ALPA granted 3 Link speed 4 number of entries in the loop init LILP ALPA map An ALPA map message is also recorded if LINK_EVENT verbose mode is set Each ALPA map message contains 16 ALPAs SEVERITY Error LOG Always ACTION If numerous link events are occurring check the physical connections to the Fibre Channel network elx_mes1304 Link Up Event ALPA map DESCRIPTION A link up event was received DATA 1 wd1 2 wd2 3 wd3 4 wd4 SEVERITY Warning LOG LOG_LINK_EVENT verbose ACTION If numerous link events are occurring check the physical connections to
54. er Error If this problem persists report errors to the Technical Support Driver for Linux Troubleshooting Section Page 67 Elx_mes1058 Waiting for authentication service DESCRIPTION There was a delay when the authentication service was not initially available as expected DATA None SEVERITY Warning LOG LOG_SECURITY ACTION Software driver warning If this problem persists report these errors to Technical Support Elx_mes1059 Authentication became avaiable DESCRIPTION The authentication service came online but was not initially available as expected DATA None SEVERITY Warning LOG LOG_SECURITY ACTION Software driver warning If this problem persists report these errors to Technical Support Miscellaneous Events 1200 1299 elx_mes1209 C_CT request error DESCRIPTION The CT response returned more data than the user buffer could hold DATA 1 outdmp gt flag 2 4096 SEVERITY Information LOG LOG_LIBDFC verbose ACTION Modify the user application issuing a CT request to allow for a larger response buffer Link Events 1300 1399 elx_mes1300 Re establishing Link timer expired DESCRIPTION The driver detected a condition where it had to re initialize the link DATA 1 fc_flag 2 hba_state SEVERITY Error LOG Always ACTION If numerous link events are occurring check the physical connections to the Fibre Channel network elx_mes1301 Re establishing Link DESCRIPTION The driver det
55. er eee te ee caeeeeeeeeteeeecaaeeeeeeeeenteee 69 VPorn Events 180021832 henii N 70 Driver for Linux User Manual Page iv Installation Driver Information Supported Features SNIA CTP compliant SMI S 1 1 Provider Topology support FC AL point to point fabric with auto topology negotiation Support for 1 2 4 and 8 gigabit Gb with auto rate negotiation Protocols SCSI FCP FCP 2 FC Tape profile including use of ADISC instead of PLOGI FC initiator mode Tested up to thirty two host bus adapter HBA ports Supports the latest HBAnyware configuration utility version 3 4 as part of the master kit enabling GUI based driver configuration including inband FC and out of band TCP IP remote storage area network SAN management capability diagnostics loopback and diagnostics dump and FC SP Authentication DH CHAP Diffie Hellman Challenge Handshake Authentication Protocol Refer to the HBAnyware 3 4 User Manual for more information Support for Common HBA API Batch firmware download capability Support for the sysfs interface PCI hot plug support Vital Product Data VPD support Linux Tools link on the Linux portion of the Emulex Web site visit the link to see the available tools Supports the LPe1250 LPe1252 LPe12000 and LPe12002 8 Gb 2 Gb and 4 Gb capable HBA s Supports FC SP DH CHAP Authentication Supports NPIV virtual ports Prerequisites For the Ipfc Driver Kit To install the Ipfc driver ki
56. er into an upgraded kernel The method you use depends on whether or not you are upgrading the driver Upgrade the kernel using the same version of the driver Upgrade the kernel using a new version of the driver See the Installation section for these procedures Driver uninstall fails The Ipfc install uninstall script fails with an error Try the following solutions e Uninstall the HBAnyware and SSC software packages These can be removed by running the uninstall script from the HBAnyware installation directory e Unmount all FC disk drives Unload the Ipfcdfc and Ipfc driver Use rpm e lpfcdriver and e hbanyware and uninstall the new kits Ipfc install script exit code The Ipfc install script contains exit codes that can be useful in diagnosing installation problems See the Ipfc install script for a complete listing of codes and definitions The HBAnyware software package will not install An error message states that inserv Service Elxlpfc has to be enabled for service ElxDiscSrvinserv exiting now sbin inserv failed exit code 1 Reinstall the driver with the Ipfc install script Driver for Linux Troubleshooting Section Page 31 Table 6 General Driver Situations Continued Situation Resolution The Emulex driver for Linux does not load Custom built kernels are not supported by Emulex However in ramdisk for a custom built kernel the Emulex install s
57. er it s dev sd name or a file system LABEL to use the persistent name as well Using udev with st Devices The udev rules for tape devices are the same for disk devices There must be a unique ID that persists across initiator reboots and persists regardless of discovery order Another thing to consider is whether or not the tape device is one of many SCSI tape devices residing behind an FC controller or if it is an FC Tape device If it an FC Tape device then the WWPN is unique and can be used to create the persistent name In fact the scsi_id program should return this as the unique identifier with a single digit prefix If the FC controller has multiple SCSI tape devices behind it the WWPN is not unique and the persistent name must use multiple information elements to build the unique ID Below are examples of each scenario The first example is that of an FC Tape device This example uses SCSI generic sg rather than the SCSI tape driver root localhost scsi_id g s sys class scsi_generic sg0 350060b000029b592 The value returned has a leading prefix of 3 This value is the NAA type and what follows is the controller s WWPN Below is an example of the same tape device and a scsi_id call The response is the same root localhost scsi_id g s sys class scsi_tape nst0 350060b000029b592 Driver for Linux Configuration Section Page 19 In both examples g was needed because the vendor and model for this tape device were
58. etc init d fcauthd status To start fcauthd execute etc init d fcauthd start If a SAN configuration has 256 targets mapped by the Ipfc driver any additional added targets do not get a target ID mapping by the driver and cause target discovery to fail Removing targets or reinitializing the link does not solve the problem Unload and reload the driver to reset available target IDs Ensure that the SAN configuration is correct prior to rebooting the driver This will clear the driver s consistent binding table and free target IDs for new target nodes In some cases after loading an OEM supplied combined firmware OpenBoot image you will not be able to enable BootBIOS from the Iputil Boot BIOS Maintenance menu Should you encounter this problem after loading the OEM combined firmware OpenBoot image follow the steps outlined in the resolution 1 Download the current OpenBoot only image for your adapter from the Emulex Web site 2 Load the current OpenBoot only image following steps listed in Updating BootBIOS section of this manual 3 Run Iputil return to Boot BIOS Maintenance menu 4 Enable BootBIOS rmmod fails to unload Ipfc driver module due to ERROR Module Ipfc is in use This message can appear when you attempt to remove the driver and there is a Logical Volume Group dependent on the driver 1 Make the Logical Volume Group unavailable Type Ilvchange a Nn XXXXXXX where xxxxxx is the Volume
59. ggins If problem persists contact Technical Support elx_mes0127 ELS timeout DESCRIPTION An ELS IOCB command was posted to a ring and did not complete within ULP timeout seconds DATA 1 elscmd 2 remote_id 3 ulpcommand 4 ulploTag SEVERITY Error LOG Always ACTION If no ELS command is going through the adapter reboot the system If problem persists contact Technical Support elx_mes0128 Xmit ELS ACC response tag lt ulploTag gt DESCRIPTION An ELS accept response for the specified IO tag has been sent DATA 1 ulpContext 2 nlp_ DID 3 nlp_flag 4 nlp_state 5 nlp_rpi SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0129 Xmit ELS RJT lt rejectError gt response tag lt ulploTag gt DESCRIPTION An ELS reject response with the specified error for the specified IO tag has been sent DATA 1 ulpContext 2 nlp_ DID 3 nlp_flag 4 nlp_state 5 nip_rpi SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0130 Xmit ADISC ACC response tag lt ulploTag gt DESCRIPTION An ADISC ACC response for the specified IO tag has been sent DATA 1 ulpContext 2 nlp_DID 3 nlp_flag 4 nlp_state 5 nip_rpi SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0131 Xmit PRLI ACC response tag lt ulploTag gt DESCRIPTION A PRLI ACC response for the specified IO tag has been sent
60. hardware resources RPI that the driver requires Ina SAN where there are other initiators this feature will greatly reduce the number of RPI that the driver utilizes lpfc_peer_port_login read 0 Off sys class scsi_host hostX lpfc_peer_port_login write default 1 On This entry sets the port s behavior when discovering targets in the SAN The default behavior 0 will only login to nports that are physically located on a different port The port will still attempt to login to targets on all other ports including the other port in a dual ported HBA If this parameter is turned on 1 then the port will attempt to login to all nports even if they are physically located on the same port NOTE This parameter was created to reduce the amount of hardware resources RPI that the driver requires Ina configuration where there are many vports on one physical port this feature will greatly reduce the number of RPI that the driver utilizes Vport Configuration Limits The following is a list of limits that are supported by the 8 2 driver and configurations that were tested with it It is highly recommended that you adhere to these limits Configurations exceeding any one or more of these limits are unsupported These limits are broken up into two groups Enforced limits are limits that the driver is able to enforce and will prevent the user from exceeding Un enforced limits are limits that the driver cannot enforce and configurations that excee
61. he max scatter Yes gather segment count passed to the driver Ipfc_sli_mode 0 0 auto default This parameter allows you No 2 SLI 2 mode to force the SLI mode 3 SLI 3 mode requested by the HBA only available on driver newer HBAs Driver for Linux Configuration Section Page 15 Table 3 Ipfc Static Parameters Requires a driver reload to change Continued Visible Variable Default Min Max Comments using sysfs lpfc_max_luns 256 1 32768 Specifies the maximum Yes number of LUN IDs per target A value of 20 means LUN IDs from 0 to 19 are valid The SCSI layer will scan each target until it reaches the specified LUN ID Ipfc_multi_ring_rctl 4 1 255 Identifies RCTL for Yes additional ring configuration NOTE Only used when multi_ring_support is enabled Ipfc_multi_ring_support 1 1 2 Determines the number of Yes primary SLI rings over which to spread IOCB entries Ipfc_multi_ring_type 5 1 255 Identifies TYPE for Yes additional ring configuration NOTE Only used when multi_ring_support is enabled Ipfc_use_msi 0 0 MSI disabled Controls whether the driver Yes 1 MSI enabled uses Message Signaled 2 MSI X enabled Interrupts All Ipfc dynamic parameters are read write using sysfs Table 4 Ipfc Dynamic Parameters Do not require a driver reload to change Variable Default Min Max Comments Ipfc_cr_count 1 1 255 This parameter determines the values fo
62. ice parameters were received from DID Ignoring this remote port DATA DID WWN SEVERITY Error LOG Always ACTION Verify the remote port s configuration If the problem persists report the error to Technical Support Run with verbose mode on for more details elx_mes0208 Skip lt Did gt NameServer Rsp DESCRIPTION The driver received a NameServer response DATA 1 size 2 fc_flag 3 fe_rscn_id_cnt SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational elx_mes0209 CT request completes lt ulpStatus gt lt ulpStatus gt lt CmdRsp gt lt CmdRsp gt DESCRIPTION A RFT request that was sent to the fabric completed DATA latt ulpStatus CmdRsp Context Tag SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational elx_mes0210 Continue discovery with lt num_disc_nodes gt ADISCs to go DESCRIPTION A device discovery is in progress DATA 1 fc_adisc_cnt 2 fc_flag 3 phba gt hba_state SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational elx_mes0211 DSM in event lt evt gt on NPort lt nlp_DID gt in state lt cur_state gt DESCRIPTION The driver Discovery State Machine is processing an event DATA 1 nlp_flag SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Driver for Linux Troubleshooting Section Page 40 elx_mes0212 DSM out state lt rc gt on NPo
63. increase the SCSI command timeout to a value greater than or equal to sixty seconds Emulex also provides a script which addresses this issue for 2 6 kernels To access the lun_change_state sh script click http www emulex com support linux index jsp then click the link to the appropriate driver and click the Linux tools link Under certain conditions of an I O load some targets cannot retire an I O issued by a Linux initiator within the default timeout of 30 seconds given by the scsi midlayer If the situation is not corrected the initiator to target condition deteriorates into abort recovery storms leading to I O failures in the block layer These types of failures are preceded by a SCSI IO error of hex 6000000 Emulex provides a script which addresses this issue To access the set_target_timeout sh script click http www emulex com support linux index jsp then click the link to the appropriate driver and click the Linux tools link Ipfc driver fails to recognize an HBA and logs unknown IOCB messages in the system log during driver load The HBA is running outdated firmware Upgrade HBA firmware to minimum supported revision listed in installation guide or newer Loading the Ipfc driver on SLES 10 reports unsupported module tainting kernel in system log This message is logged by the kernel whenever a module which is not shipped with the kernel is loaded This message can be ignored System pani
64. ion in boot grub menu st to change all hd1 references to hd0 Installing the Applications Kit Follow these instructions to install the Application Kit on your system The Applications Kit contains the HBAnyware utility Note If you wish to use DH CHAP Authentication you must install the Applications kit The Applications kit includes the fcauthd daemon software See DH CHAP Authentication and Configuration on page 26 for more information Prerequisites e The Ipfc driver must be installed Procedure To install the Applications Kit Log on as root 2 Download the utilities from the Emulex Web site or copy them to the system from the installation CD 3 Copy the ElxLinuxApps lt AppsRev gt lt DriverRev gt tar file to a directory on the install machine Change use cd command to the directory to which you copied the tar file Untar the file Type tar xvf ElxLinuxApps lt AppsRev gt lt DriverRev gt tar 6 Uninstall any previously installed versions Type uninstall Driver for Linux Installation Section Page 6 7 Run the install script Type install 8 Enter the type of management you want to use 1 Local Mode HBA s on this Platform can be managed by HBAnyware clients on this Platform Only 2 Managed Mode HBA s on this Platform can be managed by local or remote HBAnyware clients 3 Remote Mode Same as 2 plus HBAnyware clients on this Platform can manage local and remote HBA s 9 Yo
65. is problem persists report errors to the Technical Support Driver for Linux Troubleshooting Section Page 64 Elx_msg1033 Received auth_negotiate from Nport lt nlp DID gt DESCRIPTION Unsolicited authentication negotiation message received from a port DATA nlp_DID SEVERITY Warning LOG LOG_SECURITY ACTION No action this message is informational Elx_msg1034 Not Expecting Challenge Rejecting Challenge DESCRIPTION Unsolicited authentication challenge received from a port was rejected DATA None SEVERITY Warning LOG LOG_SECURITY ACTION Software driver warning If this problem persists report errors to the Technical Support Elx_msg1035 Transport ID does not match Rejecting Challenge DESCRIPTION Security Authentication failed due to contradictory Transport ID DATA None SEVERITY Error LOG LOG_SECURITY ACTION Software driver Error If this problem persists report errors to the Technical Support Elx_mag1036 Authentication transaction reject re auth request reason lt reason gt exp lt explaination gt DESCRIPTION An Authentication was rejected and requested again due to reason as displayed with explanation DATA 1 reason 2 explanation SEVERITY Error LOG LOG_SECURITY ACTION Software driver Error If this problem persists report errors to the Technical Support Elx_msg1037 Authentication transaction reject restarting authentication reason lt reason gt exp lt explaination
66. istent name for a boot device SLES 10 1 In boot grub menu st find the kernel line for the default boot For example kernel boot vmlinuz root dev sda2 vga 0x314 2 Find the persistent name for the root partition following root on the kernel line by using the instructions in Using udev to Discover Logical to Physical Mappings for sd Devices section on this page 3 Inthe same file ooot grub menu Ist replace the text after root with the partition s persistent name For example kernel boot vmlinuz root dev disk by id scsi 32000000c5005d6e6 part2 vga 0x314 4 Change any mounts listed in etc fstab which refer to this root partition by either it s dev sd name or a file system LABEL to use the persistent name as well To use a persistent name for a boot device RHEL 5 1 In boot grub grub conf find the kernel line for the default boot For example kernel boot vmlinuz lt kernel version gt ro root dev sda2 2 Find the persistent name for the root partition following root on the kernel line by using the instructions in Using udev to Discover Logical to Physical Mappings for sd Devices section on this page 3 Inthe same file ooot grub menu I st replace the text after root with the partition s persistent name For example kernel boot vmlinuz lt kernel version gt ro root dev disk by id scsi 32000000c5005d6e6 part2 4 Change any mounts listed in etc fstab which refer to this root partition by eith
67. l Connect for Fibre Channel on the BladeSystem c Class platform In such environments HBAnyware must be deployed across all servers on the SAN as well as any other management console used for out of band management so that all adapters appear in the discovery tree Driver for Linux Installation Section Page 2 Installing the Driver Kit The Ipfc install script installs the lpfcdriver_2 6 RPM The RPM e Installs the driver source files to the usr src Ipfc directory e Builds the driver for the currently running kernel e Installs the driver to the proper directory for the currently running kernel Maintenance and errata kernels are supported Once the RPM is installed the Ipfc install script creates a new ramdisk for the currently running kernel so that the Ipfc driver is loaded when the kernel is initialized during system startup Note You must uninstall any previous Ipfc driver kits and or Application Helper Modules that were installed from the Emulex CD or downloaded from the Emulex Web site i e not part of a distribution before installing this driver kit This installation will fail if a previous version of the Ipfc driver or the Application Helper Module is detected Refer to Uninstalling the Driver Kit on page 9 and Uninstalling the Applications Kit on page 10 for more information When invoked without options the Ipfc install script automatically archives any driver that is shipped as part of the di
68. lways ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support elx_mes0440 elx_mes0440 Adapter failed to init READ _REV has missing revision information DESCRIPTION A firwmare revision intialization error was detected DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem Update the firmware If the problem persists report the error to Technical Support elx_mes0441 VPD not present on adapter moxCmd lt mbxCommand gt DUMP VPD mbxStatus lt mbxStatus gt DESCRIPTION The DUMP_VPD mailbox command failed DATA None SEVERITY Information LOG LOG_INIT verbose ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support Driver for Linux Troubleshooting Section Page 52 elx_mes0442 Adapter failed to init moxCmd lt mbxCommand gt CONFIG_PORT mbxStatus lt mbxStatus gt DESCRIPTION Adapter initialization failed when issuing a CONFIG_PORT mailbox command DATA 1 hbainit SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support elx_mes0446 Adapter failed to init moxCmd lt mbxCommand gt CFG_RING mbxStatus lt mbxStatus gt ring lt num gt DESCRIPTION Adapter initialization failed when issuing a CFG_RING mailbox c
69. management server running the discovery Ethernet to connect to the undiscovered server HBAnyware utility Driver for Linux Troubleshooting Section Page 32 Ipfc Log Messages Introducton Log messages are organized into logical groups based on code functionality within the Fibre Channel driver Each group consists of a block of 100 log message numbers Most groups require a single block of 100 message numbers however some groups INIT FCP require two blocks The groups and the associated number ranges are defined in the Message Log table below Table 7 Message Log Table LOG Message Verbose Mask From To Verbose Verbose Description oe Bit Definition LOG_ELS 0100 0199 0x1 ELS events LOG_DISCOVERY 0200 0299 0x2 Link discovery events LOG_SLI 0300 0399 0x800 SLI events LOG_MBOX 0300 0339 0x4 Mailbox events LOG_TEMP 0340 0347 0x100 Temperature sensor events LOG_INIT 0400 0499 0x8 Initialization events Reserved 0500 0599 LOG_IP 0600 0699 0x20 IPFC events LOG_FCP 0700 0799 0x40 FCP traffic history Reserved 0800 0899 LOG_NODE 0900 0999 0x80 Node table events LOG_SECURITY 1000 1099 0x8000 FC Security Reserved 1100 1199 LOG_MISC 1200 1299 0x400 Miscellaneous events LOG_LINK_EVENT 1300 1399 0x10 Link events Reserved 1400 1499 Reserved 1500 1599 LOG_LIBDFC 1600 1699 0x2000 IOCTL events Driver for Linux Troubleshooting Se
70. mational elx_mes0118 Xmit ELS RPS ACC response tag lt ulploTag gt DESCRIPTION An RPS ACC response for the specified IO tag has been sent DATA 1 ulpContext 2 nlp_DID 3 nlp_flag 4 nlp_state 5 nlp_rpi SEVERITY Information LOG LOG_ELS verbose ACTION None required elx_mes0119 Issue GEN REQ IOCB for NPORT lt ulpWord 5 gt DESCRIPTION Issue a GEN REQ IOCB for remote NPORT These are typically used for CT request DATA 1 ulploTag 2 hba_state SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational elx_mes0120 Xmit ELS RPL ACC response tag lt ulploTag gt DESCRIPTION An RPL ACC response for the specified IO tag has been sent DATA 1 ulpContext 2 nlp_DID 3 nlp_flag 4 nlp_state 5 nlp_rpi SEVERITY Information LOG LOG_ELS verbose ACTION None required elx_mes0121 PLOGI chkparm OK DESCRIPTION Received a PLOGI from a remote NPORT and its Fibre Channel service parameters match this HBA Request can be accepted DATA 1 nlp_DID 2 nlp_state 3 nlp_flag 4 nlp_Rpi SEVERITY Information LOG LOG_ELS verbose ACTION No action needed informational Driver for Linux Troubleshooting Section Page 37 elx_mes0125 FDISC Failed x x Fabric out of resources DESCRIPTION The fabric rejected an FDISC because the switch can not support any more Virtual ports DATA IsRjtError SEVERITY Error LOG Always ACTION Reconfigure the switch to support more NPIV lo
71. ng in one virtual port or a low number of virtual ports in the case of load balancing within a given zone If there are too many virtual ports within a single zone expected behavior will include devices going lost after link events e Minimum lifetime of a virtual port 60 seconds There is an un enforced limit of 60 seconds between the creation of a virtual port and the deletion of the same virtual port Virtual ports are designed to be an entity that lives for a long time in the system and the creation of vports is asynchronous This means that a virtual port might not be finished with Fibre Channel or SCSI discovery when the command to create a virtual port is finished e SMB 3 digit model number HBAs must be zoned so that they can not access adapters with virtual ports configured SMB HBAs have a limited number of resources that make it impossible to operate in the same zone as an HBA that has configured virtual ports DH CHAP Authentication and Configuration The Emulex driver for Linux version 8 2 0 x supports the FC SP Authentication DH CHAP Diffie Hellmann Challenge Handshake Authentication Protocol To activate FC SP Authentication between the HBA host port and Fabric F_port using DH CHAP you add the DH CHAP associated driver parameters to the driver configuration file See Driver Configuration Methods Using modprobe and etc modprobe conf on page 11 for more information The Emulex driver for Linux version 8 2 0 x supports
72. not exist NOTE This entry will delete the vport even if there are mounted file systems being accessed through this vport and or open files node_name read only 16 byte hex value sys class fc_host hostX node_name This entry displays physical or virtual port s node name This is the value that is assigned by you upon creation and transmitted to the fabric upon fabric login port_name read only 16 byte hex value sys class fc_host hostX port_name This entry displays physical or virtual port s port name This is the value that you assign when you create a vport It is transmitted to the fabric upon fabric login Driver for Linux Configuration Section Page 24 Table 5 Vport sysfs Entries Continued Vport sysfs Entries Type ao Location and Description Ipfc_restrict_login read 0 Off sys class scsi_host hostX lpfc_restrict_login vports only write 1 On default This entry sets the vport s behavior when discovering targets in the SAN The default behavior 1 prevents the vport from logging into other Initiator ports in the SAN It will also reject logins from other ports in the SAN because it assumes that all ports that send a PLOGI are Initiators When this sysfs entry is turned off the driver will attempt to login to every port that it can access in the SAN and will accept logins from all ports NOTE This parameter was created to reduce the amount of
73. nse data DATA 1 retry 2 resid SEVERITY Information LOG LOG_FCP verbose ACTION None required elx_mes0711 detected queue full lun queue depth adjusted to d DESCRIPTION The driver detected a queue full status on a scsi command response New lun queue depth is reported DATA 1 New lun queue depth SEVERITY Warning LOG LOG_FCP verbose ACTION This may indicate an oversubscribed target array Check your SAN configuration and IO workload elx_mes0714 SCSI layer issued bus reset DESCRIPTION The SCSI layer is requesting the driver to abort all I Os to all targets on this HBA DATA 1 ret SEVERITY Error LOG Always ACTION Check the state of the targets in question elx_mes0715 Bus Reset I O flush failure cnt lt cnt gt left lt index gt DESCRIPTION Timed out while waiting during a bus reset DATA none SEVERITY Information LOG LOG_FCP verbose ACTION If other errors are also occurring please report this message to Technical Support elx_mes0716 FCP read underrun expected lt len gt residual lt resid gt DESCRIPTION An FCP device provided less data than was requested DATA 1 fepi_parm 2 cmnd 0 3 underflow SEVERITY Information LOG LOG_FCP verbose ACTION None required elx_mes0717 FCP command lt cmd gt residual underrun converted to error DESCRIPTION The driver converted this underrun condition to an error based on the underflow field in the SCSI command DATA 1
74. nts 1800 1832 elx_mes1800 Could not issue unreg_vpi DESCRIPTION Driver attempt to unregister vpi failed DATA None SEVERITY Error LOG LOG_VPORT verbose ACTION Software driver error If this problem persists report these errors to Technical Support elx_mes1801 Create vport work array FAILED cannot do scsi_host_get DESCRIPTION The driver was unable to get a reference to a SCSI host DATA None SEVERITY Warning LOG LOG_VPORT verbose ACTION Software driver warning If this problem persists report these errors to Technical Support elx_mes1802 HBQ lt index gt local_hbqGetldx lt index gt is gt than hbqp gt entry_count lt count gt DESCRIPTION An error occurred when processing queue related to an HBA in a particular slot DATA 1 hbqno 2 local_hbqGetldx 3 entry_count SEVERITY Error LOG LOG_VPORT verbose ACTION Software driver error If this problem persists report these errors to Technical Support elx_mes1803 Bad hbq tag Data lt tag gt lt count gt DESCRIPTION An error occurred when processing queue related tags for an HBA in a particular slot DATA 1 tag 2 buffer_count SEVERITY Error LOG LOG_VPORT verbose ACTION Software driver error If this problem persists report these errors to Technical Support Driver for Linux Troubleshooting Section Page 70 elx_mes1805 Adapter failed to init Data lt command gt lt status gt lt queue num gt DESCRIPTION An error occu
75. nux Troubleshooting Section Page 61 Elx_msgi010 Bad Tag 1 lt message gt DESCRIPTION DH CHAP Authentication process failed when bad Tag was detected DATA message SEVERITY Error LOG LOG_SECURITY ACTION Software driver Error If this problem persists report errors to the Technical Support Elx_msg 1011 Auth_neg no hash function chosen DESCRIPTION DH CHAP Authentication process failed when an incorrect hash function was specified DATA message SEVERITY Error LOG LOG_SECURITY ACTION Software driver Error If this problem persists report errors to the Technical Support Elx_msg1012 Auth_negotiate Bad Tag lt message gt DESCRIPTION DH CHAP Authentication process failed due to bad Tag for auto negotiation DATA message SEVERITY Error LOG LOG_SECURITY ACTION Software driver Error If this problem persists report errors to the Technical Support Elx_msg 1013 Auth_negotiate no DH_group found DESCRIPTION DH CHAP Authentication process failed when incorrect or missing DH Group was detected DATA message SEVERITY Error LOG LOG_SECURITY ACTION Software driver Error If this problem persists report errors to the Technical Support Elx_msg1014 dhchap challenge bad name tag lt message gt DESCRIPTION DH CHAP Authentication process failed when incorrect Challenge name tag was detected DATA message SEVERITY Error LOG LOG_SECURITY ACTION Software driver Error If this problem persists rep
76. o go DESCRIPTION Device discovery is in progress DATA 1 fc_plogi_cnt 2 fc_flag 3 phba gt hba_state SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational elx_mes0234 ReDiscovery RSCN DESCRIPTION The number type of RSCNs has forced the driver to go to the nameserver and re discover all NPORTs DATA 1 fe_rscn_id_cnt 2 fc_flag 3 hba_state SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational elx_mes0235 Deferred RSCN DESCRIPTION The driver has received multiple RSCNs and has deferred the processing of the most recent RSCN DATA 1 fe_rscn_id_cnt 2 fc_flag 3 hba_state SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational Driver for Linux Troubleshooting Section Page 43 elx_mes0236 NameServer req DESCRIPTION The driver is issuing a NameServer request to the fabric DATA 1 cmdcode 2 fc_flag 3 fe_rscn_id_cnt SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational elx_mes0237 Pending Link Event during Discovery State lt hba_state gt DESCRIPTION Received link event during discovery Causes discovery restart DATA None SEVERITY Warning LOG LOG_DISCOVERY verbose ACTION None required unless problem persists If persistent check cabling elx_mes0238 Process lt Did gt NameServer Rsp DESCRIPTION The driver received a NameServe
77. o set lpfc_enable_auth by writing 1 to the lpfc_enable_auth sysfs parameter The default setting for the Ipfc enable auth module parameter is disabled Refer to Table 4 on page 16 for the parameter values The fcauthd Daemon The Emulex LPFC driver uses the fcauthd daemon to perform authentication tasks The feauthd daemon is installed with the Applications kit The fcauthd daemon must be running to configure an HBA port so it can initiate authentication requests or respond to authentication requests To load the driver with authentication enabled the feauthd daemon should be running prior to loading the driver The driver can start with authentication enabled if the daemon is not running but all ports will be placed into an error state and the link state of each port will be down When the daemon is started the driver will communicate with the daemon reset the HBA and process authentication requests To start or stop the daemon use the etc init d fcauthd script This script accepts the standard daemon parameters start stop reload status restart and condrestart Once the driver is loaded it only needs the authentication daemon when authentication is performed e g during link up or re authentication If the daemon is not running because it has crashed hung or has been stopped and the driver attempts authentication then authentication will fail The script syntax is etc init d fcauthd lt parameter gt Note The 8 2 0 X
78. ommand DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support elx_mes0447 Adapter failed init moxCmd lt mbxCommand gt CONFIG_LINK mbxStatus lt mbxStatus gt DESCRIPTION Adapter initialization failed when issuing a CONFIG_LINK mailbox command DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support elx_mes0448 Adapter failed to init moxCmd lt mbxCommand gt READ_SPARM mbxStatus lt mbxStatus gt DESCRIPTION Adapter initialization failed when issuing a READ_SPARM mailbox command DATA None SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support elx_mes0449 lpfc_ attr attribute cannot be initialized to d allowed range is min max DESCRIPTION Sysfs attribute value written exceeds attribute range DATA 1 attribute name 2 value written 3 minimum value 3 maximum value SEVERITY Error LOG Always ACTION Write a value within the supported range elx_mes0450 Ipfc_ attr attribute cannot be set to d allowed range is min max DESCRIPTION Sysfs attribute value written exceeds attribute range DATA 1 attribute name 2 value written 3 minimum value 3 maximum value
79. only on a driver load while others can be modified dynamically and take effect immediately The tables also list the default minimum and maximum values for these parameters Note The Linux 2 6 kernel only supports setting the lpfc_log_verbose lpfc_devioss_tmo and Ipfc_use_adisc driver parameters for individual HBAs Other driver parameters must be applied to all HBAs contained in the host Table 3 Ipfc Static Parameters Requires a driver reload to change Variable Default Min Max Comments Visible using sysfs Ipfc_ackO 0 Off 1 On Uses ACKO for class 2 Yes Ipfc_dev_loss_initiator 1 Engage devlos timeout for initiators Yes lpfc_discovery_threads 32 64 Specifies the maximum number of ELS commands that can be outstanding for a discovery NOTE The discovery_threads parameter will default to a value of 64 for private loop topologies regardless of the configured value If there are multiple ports configured on the host the value of 64 will only be used for those ports that are connected in a private loop topology The configured value will be used for all other ports No lIpfc_enable_da_id 0 Disabled default 1 enable a DA_ID CT command will be sent to the fabric when logging out This parameter controls whether the driver will issue a DA_ID CT command to the fabric when vports logout of the fabric Yes
80. oot 4096 Feb 28 15 34 sys class scsi_host host7 lpfc_log_verbose r r r 1 root root 4096 Feb 28 17 03 sys class scsi_host host7 lpfc_lun_queue_depth rw r r 1 root root 4096 Feb 28 17 03 sys class scsi_host host7 lpfc_max_luns rw r r 1 root root 4096 Feb 28 17 03 sys class scsi_host host7 lpfc_nodev_tmo rw r r 1 root root 4096 Feb 28 17 03 sys class scsi_host host7 lpfc_scan_down r r r 1 root root 4096 Feb 28 17 03 sys class scsi_host host7 lpfc_topology rw r r 1 root root 4096 Feb 28 17 03 sys class scsi_host host7 lpfc_use_adisc Notice that the driver parameters are available as files Reading a file displays the current value of a driver parameter If the permissions allow it you can write a value to the file and it will take effect immediately Driver for Linux Configuration Section Page 12 For example root emulex cat sys class scsi_host host7 lpfc_log verbose 0 Notice that the current value of lpfc_log_verbose is zero To set it to Oxffff root emulex echo Oxffff gt sys class scsi_host host7 lpfc_log verbose root emulex cat sys class scsi_host host7 lpfc_ log verbose oxffff Creating a New Ramdisk Image The Ipfc install script creates a ramdisk containing the Ipfc driver for the currently running kernel Note You must perform this step whenever the Ipfc options in etc modprobe conf are changed and you want the change to take effect on the next reboot For Installed Ipfc D
81. or Linux Troubleshooting Section Page 47 elx_mes0313 Ring lt ringno gt handler unexpected Rctl lt Rctl gt Type lt Type gt received DESCRIPTION The Rctl Type of a received frame did not match any for the configured masks for the specified ring DATA None SEVERITY Warning LOG LOG_SLI verbose ACTION This error could indicate a software driver firmware or hardware problem Report these errors to Technical Support elx_mes0315 Ring lt ringno gt issue portCmdGet lt local_getidx gt is bigger then cmd ring lt max_cmd_idx gt DESCRIPTION The port cmd ring get index is greater than the size of cmd ring DATA None SEVERITY Error LOG Always ACTION This error could indicate a software driver firmware or hardware problem Report these errors to Technical Support elx_mes0317 iotag lt ulp_loTag gt is out of range max iotag lt max_iotag gt wd0 lt wd0 gt DESCRIPTION The loTag in the completed IOCB is out of range DATA None SEVERITY Error LOG Always ACTION This error could indicate a software driver firmware or hardware problem Report these errors to Technical Support elx_mes0318 Failed to allocate IOTAG last IOTAG is lt last_allocated_iotag gt DESCRIPTION The driver cannot allocate an loTag Display the last value used DATA None SEVERITY Error LOG Always ACTION This message indicates the adapter HBA I O queue is full Typically this happens when heavy I O is running on a low en
82. ort errors to the Technical Support Elx_msg1015 dhchap challenge bad name length lt message gt DESCRIPTION DH CHAP Authentication process failed due to unexpected Challenge name length DATA message SEVERITY Error LOG LOG_SECURITY ACTION Software driver Error If this problem persists report errors to the Technical Support Driver for Linux Troubleshooting Section Page 62 Elx_msg1016 dhchap challenge Hash ID not Supported lt message gt DESCRIPTION DH CHAP Authentication process failed due to uncorroborated Challenge Hash ID DATA message SEVERITY Error LOG LOG_SECURITY ACTION Software driver Error If this problem persists report errors to the Technical Support Elx_msg1017 dhchap challenge could not find DH Group DESCRIPTION DH CHAP Authentication process failed due to uncorroborated Challenge Group DATA None SEVERITY Error LOG LOG_SECURITY ACTION Software driver Error If this problem persists report errors to the Technical Support Elx_mes1019 Request tranid lt tran_id gt timed out DESCRIPTION A transaction with storage array could not complete due to timeout DATA tran_id SEVERITY Warning LOG LOG_SECURITY verbose ACTION Software driver warning If this problem persists report these errors to Technical Support Elx_mes1020 Dropped Message type lt msg_type gt to PID lt fc_service_pid gt lt fn gt err lt err gt DESCRIPTION A netlink message was dropped due to some e
83. ort pair is disabled DATA None SEVERITY Error LOG LOG_SECURITY ACTION Configure the driver to authenticate with the switch or disable authentication on the switch to this port Elx_msg1053 Start Authentication Security service offline DESCRIPTION The authentication failed because security service was not available DATA None SEVERITY Error LOG LOG_SECURITY ACTION Software driver Error If this problem persists report errors to the Technical Support Elx_msg1055 Authentication parameter is disabled but is required by the fabric DESCRIPTION FLOGI failed because the fabric has indicated that Authentication is required but authentication has not yet been configured or enabled on the HBA DATA None SEVERITY Error LOG LOG_SECURITY ACTION Configure authentication on this HBA Elx_msg 1056 Authentication mode is disabled but is required by the fabric DESCRIPTION The discovery failed because fabric requires authentication mode but that mode is currently disabled DATA None SEVERITY Information LOG LOG_SECURITY ACTION Informational message only If you have questions please contact the Technical Support Elx_msg1057 Authentication transaction reject reason lt reason gt exp lt explaination gt DESCRIPTION An Authentication was rejected and requested again due to reason as displayed with explanation DATA 1 reason 2 explanation SEVERITY Error LOG LOG_SECURITY ACTION Software driv
84. r I O coalescing for cr_delay msec or cr_count outstanding commands Ipfc_cr_delay 0 0 63 This parameter determines the values for I O coalescing for cr_delay msec or cr_count outstanding commands Ipfc_devloss_tmo 30 0 255 Seconds to hold I O error if device disappears NOTE Emulex recommends setting the lpfc_devloss_tmo parameter to 60 when npiv is enabled Driver for Linux Configuration Section Page 16 Table 4 Ipfc Dynamic Parameters Do not require a driver reload to change Continued Variable Default Min Max Comments Ipfc_enable_auth 0 0 1 This driver property specifies if the DH CHAP is enabled or not When set to 1 DH CHAP is enabled When set to 0 DHCHAP support is disabled NOTE This property requires a link reset to activate Ipfc_fdmi_on 0 0 2 False 0 if disabled 1 or 2 if enabled depending on type of support needed Ipfc_link_speed 0 O auto select Sets link speed 1 1G 2 2G 4 4G 8 8G Ipfc_log_verbose 0x0 0x0 Oxffff bit mask Extra activity logging lpfc_nodev_tmo 30 1 255 This parameter will not work if you altered depricated Ipfc_devloss_tmo NOTE This is a deprecated field and Ipfc_devloss_tmo should be used instead lpfc_pci_max_read 2048 512 1024 2048 Maximum DMA read byte count 4096 Ipfc_poll 0 1 poll wiith Sets FCP ring polling mode control interupts enabled 3 poll and disable FCP ring inter
85. r response DATA 1 nlp_flag 2 fc_flag 3 fe_rscn_id_cnt SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational elx_mes0240 NameServer Rsp Error DESCRIPTION The driver received a NameServer response containing a status error DATA 1 CommandResponse bits CmdRsp 2 ReasonCode 3 Explanation 4 fc_flag SEVERITY Information LOG LOG_DISCOVERY verbose ACTION Check the fabric configuration The driver recovers from this and continues with device discovery elx_mes0241 NameServer rsp error DESCRIPTION The driver received a NameServer response containing a status error DATA 1 CommandResponse bits CmdRsp 2 ReasonCode 3 Explanation 4 fc_flag SEVERITY Information LOG LOG_DISCOVERY verbose ACTION Check the fabric configuration The driver recovers from this and continues with device discovery elx_mes0244 Issue FDMI request failed DESCRIPTION Cannot issue an FDMI request to the HBA DATA 1 cmdcode SEVERITY Information LOG LOG_Discovery verbose ACTION No action needed informational Driver for Linux Troubleshooting Section Page 44 elx_mes0246 RegLogin failed DESCRIPTION The firmware returned a failure for the specified RegLogin DATA Did mbxStatus hbaState SEVERITY Error LOG Always ACTION This message indicates that the firmware could not do RegLogin for the specified Did There may be a limitation on how many nodes an HBA can see elx_me
86. rbose ACTION None required elx_mes0929 FIND node DID unmapped DESCRIPTION The driver is searching for a node table entry on the unmapped node list based on DID DATA 1 ndlp 2 nlp_DID 3 nlp_flag 4 data1 SEVERITY Information LOG LOG_NODE verbose ACTION None required elx_mes0930 FIND node DID mapped DESCRIPTION The driver is searching for a node table entry on the mapped node list based on DID DATA 1 ndlp 2 nip_DID 3 nlp_flag 4 data1 SEVERITY Information LOG LOG_NODE verbose ACTION None required elx_mes0931 FIND node DID adisc DESCRIPTION The driver is searching for a node table entry on the binding list based on DID DATA 1 ndlp 2 nlp_DID 3 nlp_flag 4 data1 SEVERITY Information LOG LOG_NODE verbose ACTION None required elx_mes0932 FIND node did lt did gt NOT FOUND DESCRIPTION The driver was searching for a node table entry based on the DID and the entry was not found DATA 1 order SEVERITY Information LOG LOG_NODE verbose ACTION None required Driver for Linux Troubleshooting Section Page 60 Security Events 1000 1099 Elx_msg1003 Send dhchap challenge local wwpn lt local_wwpn gt remote_wwpn lt remote_wwpn gt DESCRIPTION Informational message during DH CHAP authentication challenge and response process DATA 1 local_wwpn 2 remote_wwpn SEVERITY Information LOG LOG_SECURITY ACTION Software driver Info Contact Technical
87. reachable by HBA 4503599627370495 Attached scsi generic sg8 at scsil4 channel 0 id 0 lun 3 type 1 type 1 This log output shows a controller at LUN 0 the medium changer at LUN 1 and two SCSI tape devices at LUNs 2 and 3 The example below is what the scsi_id call returns root localhost scsi_id g s sys class scsi_tape nst0 1IBM ULTRIUM TD2 1110133831 root localhost scsi_id g s sys class scsi_tape nst1 1IBM ULTRIUM TD2 1110133994 Notice that the unique ID is actually comprised of three value with space delimiters A udev rule must have a unique ID for the device meaning all three parts of this returned string are required To do this use the following command root localhost scsi_id u g s sys class scsi_ tape nsto 1IBM ULTRIUM TD2 1110133831 root localhost scsi_id u g s sys class scsi_tape nst1 1IBM ULTRIUM TD2 1110133994 Creating the udev persistent name for SCSI tape uses the same process as SCSI disk once the SCSI ID call needed to extract a unique ID is known Below is the rule for the FC Tape device BUS scsi SYSFS vendor HP SYSFS model ULTRIUM 3 SCSI PROGRAM sbin scsi_id p 0x83 u g s sys class scsi_tape nst n RESULT 350060b000029b592 SYMLINK fc_lun st n Driver for Linux Configuration Section Page 20 The rule for the FC SCSI tape device follows BUS scsi SYSFS vendor IBM SYSFS model ULTRIUM TD2 PROGRAM sbin scsi_id p 0x83 u g s sys class
88. river Kits To create a new initial ramdisk image su to root 2 Type cd usr src lpfc 3 Execute the lpfc install script using the createramdisk option Type lpfc install createramdisk For Distribution In Box Ipfc Drivers To create a new initial ramdisk image e For SLES10 PPC64 architecture distributions type mkinitrd k vmlinux i initrd e For SLES10 non PPC64 architecture distributions type mkinitrd k vmlinuz i initrd e For RHEL5 PPC64 and non PPC64 architecture distributions type mkinitrd f boot initrd lt kernel version gt img lt kernel version gt Dynamically Adding LUNs and Targets The Emulex driver for Linux enables you to dynamically add LUNs and targets without unloading or reloading the Ipfc module and without resetting the adapter To rescan an HBA s targets with sysfs given the HBA s host number in this example 3 type echo gt sys class scsi_host host3 scan To limit the rescan to a particular target given the HBA s host number in this example 3 and the target number in this example 2 type echo 2 gt sys class scsi_host host3 scan You can also use the Emulex lun_scan script in usr sbin Ipfc Driver for Linux Configuration Section Page 13 Driver Parameters Reference Table The driver parameters determine some aspects of the driver behavior The following tables list the driver parameters Some driver parameters can be modified and take effect
89. rred when processing queue related tags for an HBA in a particular slot DATA 1 mbxCommand 2 mbxStatus 3 hbaqno SEVERITY Error LOG LOG_VPORT verbose ACTION Software driver error If this problem persists report these errors to Technical Support elx_mes1806 Mbox lt command gt failed No vport DESCRIPTION A mailbox command could not be communicated because there was no vport associated with the mailbox command DATA mbxCommand SEVERITY Error LOG LOG_VPORT verbose ACTION Software driver error If this problem persists report these errors to Technical Support elx_mes1807 IOCB lt value gt failed No vport DESCRIPTION An IOCB command could not be communicated because there was no vport associated with the mailbox command DATA ulpCommand SEVERITY Error LOG LOG_VPORT verbose ACTION Software driver error If this problem persists report these errors to Technical Support elx_mes1808 Create VPORT failed NPIV is not enabled SLImode lt mode gt DESCRIPTION The driver failed to create a port because the HBA was in wrong mode or was not capable of NPIV DATA 1 sli_rev SEVERITY Error LOG LOG_VPORT verbose ACTION Load the driver with npiv enabled on an HBA that supports SLI 3 elx_mes1809 Create VPORT failed Max VPORTs lt vpi gt exceeded DESCRIPTION The driver failed to create a port because the maximum number of port supported by the driver will be exceeded DATA 1 max_vpi SEVER
90. rror Display shows the message type PID service pid function and error DATA 1 msg_type 2 fe_service_pid 3 fn 4 err SEVERITY Warning LOG LOG_SECURITY ACTION Software driver warning If this problem persists report these errors to Technical Support Elx_mes1021 ERROR attempted to queue security work when no workqueue created DESCRIPTION Driver encountered missing queue required for processing security information DATA None SEVERITY Error LOG LOG_SECURITY ACTION Software driver Error If this problem persists report these errors to Technical Support Elx_mes1022 Security request does not exist DESCRIPTION A security request operation failed because there was no match found for such request DATA None SEVERITY Warning LOG LOG_SECURITY ACTION Software driver warning If this problem persists report these errors to Technical Support Driver for Linux Troubleshooting Section Page 63 Elx_mes1023 Warning data may have been truncated Data lt data gt reqdl lt data_len gt mesdi lt data_len gt DESCRIPTION A security message exchange operation failed because the response was missing or unreliable DATA None SEVERITY Warning LOG LOG_SECURITY ACTION Software driver warning If this problem persists report these errors to Technical Support Elx_ msg1025 Received security config local_ wwpn lt gt remote_wwpn lt gt mode lt gt hash lt gt bidir lt gt dh_group lt gt r
91. rt lt nlp_DID gt DESCRIPTION The driver Discovery State Machine completed processing an event DATA 1 nlp_flag SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational elx_mes0214 RSCN received DESCRIPTION An RSCN ELS command was received from a fabric DATA 1 fc_flag 2 payload_len 3 Ip 4 fe_rscn_id_cnt SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational elx_mes0215 RSCN processed DESCRIPTION An RSCN ELS command was received from a fabric and processed DATA 1 fc_flag 2 cnt 3 fe_rscn_id_cnt 4 hba_state SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational elx_mes0217 Unknown Identifier in RSCN payload DESCRIPTION Typically the identifier in the RSCN payload specifies a domain area or a specific NportID If neither of these are specified a warning will be recorded DATA 1 un word SEVERITY Error LOG Always ACTION Potential problem with Fabric Check with Fabric vendor elx_mes0218 FDMI Request DESCRIPTION The driver is sending an FDMI request to the fabric DATA 1 fc_flag 2 hba_state 3 cmdcode SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational elx_mes0220 FDMI rsp failed DESCRIPTION An error response was received to FDMI request DATA 1 SWAP_DATA16 fdmi_cmd SEVERITY Information LOG LOG_DISCOVERY verbose ACT
92. rupts Ipfc_poll_tmo 10 1 255 Milliseconds the driver waits between polling FCP ring interrupts Ipfc_topology 0 0x0 loop Fibre Channel link topology defaults to then P2P loop if it fails attempts point to point 0x2 P2P only mode 0x4 loop only 0x6 P2P then loop Ipfc_use_adisc 0 0 Off 1 On Sends ADISC instead of PLOGI for device discovery or RSCN Driver for Linux Configuration Section Page 17 Using udev for Persistent Naming SLES 10 is configured by default with udev to provide persistent names for hard disks including FC attached disks Using udev to Discover Logical to Physical Mappings for sd Devices Persistent names for sd devices are provided in the dev disk by id directory To find the persistent udev name for the disk which is currently sdc type cd dev disk by id 1s 1 grep sdc The sample output is shown below Irwxrwxrwx 1 root root 9 2006 08 01 19 08 scsi 32000000c5005d66e6 gt sdc In the above example the disk has no partitions If the disk had two partitions the output would look like the following Irwxrwxrwx 1 root root 9 2006 08 01 19 08 scsi 32000000c5005d6e6 gt sdc Irwxrwxrwx 1 root root 10 2006 08 01 19 08 scsi 32000000c5005d6e6 parti gt sdc1 Irwxrwxrwx 1 root root 10 2006 08 01 19 08 scsi 32000000c5005d6e6 part2 gt sdc2 Driver for Linux Configuration Section Page 18 Configuring the System to Boot From SAN Using Persistent Names To use a pers
93. s to Technical Support elx_mes1815 Could not issue unreg_did default rpis DESCRIPTION Attempt to unregister rpi failed DATA None SEVERITY Error LOG LOG_VPORT verbose ACTION Software driver error If this problem persists report these errors to Technical Support elx_mes1816 FLOGI NPIV supported response data lt port gt DESCRIPTION The fabric reports support for NPIV upon FLOGI DATA 1 response_multiple_NPort SEVERITY Warning LOG LOG_VPORT verbose ACTION No action needed informational elx_mes1817 Fabric does not support NPIV configuring single port mode DESCRIPTION The fabric reports no support for NPIV upon FLOGI DATA None SEVERITY Warning LOG LOG_VPORT verbose ACTION No action needed informational Driver for Linux Troubleshooting Section Page 72 elx_mes1818 VPort failed init mbxCmd lt mailbox command gt READ _SPARM mbxStatus lt mailbox status gt rc lt status gt DESCRIPTION A pending mailbox command issued to initialize port failed DATA 1 mbxCommand 2 mbxStatus 3 rc SEVERITY Error LOG LOG_VPORT verbose ACTION Software driver error If this problem persists report these errors to Technical Support elx_mes1819 Unrecognized Ipfc_sli_mode parameter lt mode gt DESCRIPTION The user has attempted to set the SLI mode to an invalid value The only valid values for the SLI mode are 0 2 and 3 DATA 1 lpfc_sli_mode SEVERITY Error LOG LOG_VPORT verbo
94. s0247 Start Discovery Timer state lt hba_state gt DESCRIPTION Start the device discovery RSCN rescue timer DATA 1 tmo 2 fe_disctmo 3 fc_plogi_cnt 4 fc_adisc_cnt SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational elx_mes0248 Cancel Discovery Timer state lt hba_state gt DESCRIPTION Cancel the device discovery RSCN rescue timer DATA 1 fc_flag 2 fc_plogi_cnt 3 fe_adisc_cnt SEVERITY Information LOG LOG_DISCOVERY verbose ACTION No action needed informational elx_mes0253 Illegal State Transition node lt nlp_DID gt event lt evt gt state lt nlp_state gt DESCRIPTION An unexpected response was received from the specified node DATA 1 nlp_rpi 2 nlp_flag SEVERITY Error LOG Always ACTION Check connection to fabric and or remove device If problem persists please report the issue to Technical Support Mailbox Events 0300 0339 elx_mes0300 READ_LA no buffers DESCRIPTION The driver attempted to issue a READ_LA mailbox command to the HBA but there were no buffers available DATA None SEVERITY Warning LOG LOG_MBOX verbose ACTION This message indicates 1 Kernel virtual memory is depleted Check that the system meets minimum RAM requirements for the Emulex Fibre Channel adapter Try closing other applications to free some memory 2 A possible driver buffer management problem If this problem persists report the error to Technical S
95. se ACTION The Ipfc_sli_mode driver parameter setting must be corrected Valid values are 0 2 and 3 elx_mes1820 Unable to select SLI 3 Not supported by adapter DESCRIPTION The HBA is not capable of operating in a given mode DATA None SEVERITY Error LOG LOG_VPORT verbose ACTION SLI 3 mode is only available on some HBAs Do not attempt to force the SLI mode to 3 on HBAs that do not support SLI 3 mode This is an informational message HBAs that do not support SLI 3 will be configured to run in SLI 2 mode but it is recommended to use the auto setting 0 elx_mes1821 Create VPORT failed Invalid WWN format DESCRIPTION The port could not be created due to an invalid WWNN or WWPN format DATA None SEVERITY Error LOG LOG_VPORT verbose ACTION Provide a valid WWN when creating Vports elx_mes1822 Invalid lt name gt lt xx XX XX XX XX XX XX XX gt DESCRIPTION An invalid WWN was used when creating a vport DATA 1 type_name 2 wwn 1 3 wwn 3 3 wwn 5 4 wwn 7 SEVERITY Error LOG LOG_VPORT verbose ACTION When creating a vport you must furnish a valid WWN elx_mes1823 Create VPORT failed Duplicate WWN on HBA DESCRIPTION The port could not be created because it would duplicate an existing WWNN HBA address The resources for the port had to be discarded DATA None SEVERITY Error LOG LOG_VPORT verbose ACTION Provide a WWN that is unique Driver for Linux Troubleshooting Section Pag
96. stall the HBAnyware and Iputil utilities and their associated files Note If the HBAnyware Security Configurator is installed it must be uninstalled before uninstalling the HBAnyware and Iputil utilities Uninstalling the HBAnyware Security Configurator Note You must run the uninstall script that shipped with the version of HBAnyware Security Configurator you want to remove To uninstall the HBAnyware Security Configurator 1 Log on as root 2 Change use cd command to the directory to which you copied the tar file during installation 3 Run the uninstall script with the ssc parameter specified Type uninstall ssc Uninstalling HBAnyware with Web Launch Note If you installed HBAnyware with Web Launch you must uninstall it before uninstalling HBAnyware To uninstall HBAnyware with Web Launch 1 Logon as root 2 Execute the following script usr sbin hbanyware wsuninstall This script stops the HBAnyware Web Launch Service daemons if they are running and removes all Web Launch related files from the host Uninstalling HBAnyware Note You must run the uninstall script that shipped with the version of the HBAnyware utility that you want to remove Note If you installed HBAnyware with Web Launch you must uninstall it before uninstalling HBAnyware To uninstall the HBAnyware and Iputil utilities and the Application Helper Module 1 Logon as root 2 Change use c
97. stribution s kernel during the installation procedure Old drivers that are archived during installation are then restored when the driver kit is uninstalled Note The HBAnyware utility must be installed separately from the driver Refer to the Installing the Utilities on page 10 for more information Note The Ipfc install script does not support custom kernels For example kernels with Version_Release strings that do not match those of the original distribution kernel To install the Emulex driver for Linux 1 Install a supported Emulex HBA in the system Refer to the HBA s Installation manual for specific hardware installation instructions 2 Remove any previously installed Ipfc driver kits and or Application Helper Modules that were installed from the Emulex CD or downloaded from the Emulex Web site i e not part of a distribution s kernel before proceeding Refer to Uninstalling the Driver Kit on page 9 and Uninstalling the Applications Kit on page 10 for more information 3 Download the driver kit from the Emulex Web site or copy it to the system from the installation CD 4 Logon as root to a terminal and unpack the tarball with the following command tar xzf lpfc_2 6 driver _kit lt driver version gt tar gz 5 Change to the directory that is extracted cd lpfc 2 6 driver _kit lt driver version gt 6 Execute the Ipfc install script with no options to install the new driver kit Type
98. sued to the fabric to delete an associated resource for an object such as for a port failed DATA None SEVERITY Error LOG LOG_VPORT verbose ACTION Software driver error If this problem persists report these errors to Technical Support Driver for Linux Troubleshooting Section Page 74 elx_mes1830 Signal aborted mbxCmd lt command gt DESCRIPTION A pending mailbox command was aborted because the thread received a signal DATA None SEVERITY Error LOG LOG_VPORT verbose ACTION You should retry the attempted command elx_mes1831 Create VPORT Interrupted DESCRIPTION The port creation process was unexpectedly interrupted at a critical time and the operation was unsuccessful DATA None SEVERITY Error LOG LOG_VPORT verbose ACTION The process was interrupted while creating a vport Retry the command elx_mes1832 Delete VPORT can not proceed at this time due to SCSI layer busy DESCRIPTION An attempt to delete a port failed because it was deemed unsafe as the system was not was not in proper state such as link down or SCSI layer has not released all the targets associated with the port DATA None SEVERITY Error LOG LOG_VPORT verbose ACTION Retry the command If this problem persists report these errors to Technical Support Driver for Linux Troubleshooting Section Page 75
99. t the appropriate distribution kernel development packages must be installed for the currently running kernel which include the gcc compiler and the kernel sources The Ipfc driver kit supports the following distributions Red Hat Enterprise Linux 5 and 5 1 Intel x86 Intel Itanium2 Intel EM64T AMD64 and PowerPC 64 bit architectures SuSE Linux Enterprise Server 10 SP1 Intel x86 Intel Itanium2 Intel EM64T AMD64 and PowerPC 64 bit architectures The Applications kit must be installed to use DH CHAP Authentication The Applications kit includes the fcauthd daemon software Driver for Linux Installation Section Page 1 Compatibility e LPe12000 and LPe12002 firmware version 1 00a9 or later is recommended e LPe1250 and LPe1252 firmware version 1 00a9 or later is recommended e LPe11000 LPe11002 and LPe1150 firmware version 2 72a2 or later is recommended e LP11000 LP11002 and LP1150 firmware version 2 72a2 or later is recommended e LP1005DC CM2 minimum firmware version 1 90a5 e LP10000ExDC and LP1050Ex minimum firmware version 1 91a1 e LP10000DC and LP10000 minimum firmware version 1 91a1 e LP1050DC and LP1050 minimum firmware version 1 91a1 e LP9802DC and LP9802 minimum firmware version 1 91a1 e LP982 minimum firmware version 1 91a1 e LP9402DC LP9002DC LP9002L and LP9000 minimum firmware version 3 93a0 e LP952L minimum firmware version 3 93a0 LP8000 and LP8000DC e If your HBA has a
100. te of the device in question elx_mes0704 At limitation of lt total gt preallocated command buffers DESCRIPTION The maximum number of command buffers have already been allocated DATA None SEVERITY Warning LOG LOG_FCP verbose ACTION None required elx_mes0705 Allocation request of lt num gt command buffers will exceed max of lt hba_queue_depth gt Reducing allocation request to lt size gt DESCRIPTION The number of command buffers requested will exceed the maximum so a smaller quantity will be allocated DATA None SEVERITY Warning LOG LOG_FCP verbose ACTION None required elx_mes0706 Failed to allocate command buffer DESCRIPTION There was not enough memory on the system to allocate a command buffer DATA None SEVERITY Error LOG Always ACTION This error could indicate a heavily loaded system or a memory leak If the problem persists report the error to Technical Support elx_mes0707 driver s buffer pool is empty IO busied DESCRIPTION Resources were not available to process an IO request A busy status will be returned DATA None SEVERITY Information LOG LOG_FCP verbose ACTION None required Driver for Linux Troubleshooting Section Page 56 elx_mes0710 lodone lt target gt lt lun gt cmd lt cmd gt error lt result gt SNS lt lp gt lt lp3 gt DESCRIPTION This error indicates that the Fibre Channel driver is returning a SCSI command to the SCSI layer in error or with se
101. ted by the fc_hosts underlying hardware This sysfs entry will only exist if the vport_create and vport_delete sysfs entries exist If an fc_host does not support NPIV then this sysfs entry may not exist NOTE Use this sysfs entry along with npiv_vports_inuse to determine whether the maximum number of vports have been created on this fc_host vport_create write only WWPN WWNN sys class scsi_host hostX vport_create This entry creates a vport on the physical port that hostX is located on The new vport will have present a WWPN and WWNN on the fabric as indicated by the WWPN and WWNN that is input to this sysfs entry This sysfs entry will return a 0 if the vport creation was successful A non zero value indicates that the vport failed to be created If an fc_host does not support NPIV then this sysfs entry may not exist NOTE It is possible for the vport creation to succeed but for the vport to be in a failed or inoperative state Use the new sysfs tree created by the new vport to check the state of the new vport vport_delete write only WWPN WWNN sys class scsi_host hostX vport_delete This entry deletes a vport on the physical port that hostX is located on The vport matching the WWPN and WWNN will be immediately deleted This entry returns a 0 if the vport deletion was successful A non zero value indicates that the vport failed to be deleted If an fc_host does not support NPIV then this sysfs entry may
102. ter Hardware Error DESCRIPTION The driver received an interrupt indicating a possible hardware problem Data 1 status 2 status1 3 status2 SEVERITY Error LOG Always ACTION This error could indicate a hardware or firmware problem If the problem persists report the error to Technical Support elx_mes0458 Bring adapter online DESCRIPTION The FC driver has received a request to bring the adapter online This may occur when running Iputil DATA None SEVERITY Warning LOG LOG_INIT verbose ACTION None required Driver for Linux Troubleshooting Section Page 54 elx_mes0460 Bring adapter offline DESCRIPTION The FC driver has received a request to bring the adapter offline This may occur when running Iputil DATA None SEVERITY Warning LOG LOG_INIT verbose ACTION None required elx_mes0462 Too many cmd rsp ring entries in SLI2 SLIM DESCRIPTION The configuration parameter for Scan down is out of range DATA 1 totiocb 2 MAX_SLI2_IOCB SEVERITY Error LOG Always ACTION This is a software driver error If this problem persists report these errors to Technical Support elx_mes0466 Too many cmd rsp entries in SLI2 SLIM DESCRIPTION The driver has configured too many command and response IOCBs in all rings DATA 1 total configured IOCBs 2 maximum number allowed SEVERITY Error LOG Always ACTION This error could indicate a software driver firmware or hardware problem Report
103. the Fibre Channel network elx_mes1305 Link Down Event lt eventTag gt received DESCRIPTION A link down event was received DATA 1 fc_eventTag 2 hba_state 3 fc_flag SEVERITY Error LOG Always ACTION If numerous link events are occurring check the physical connections to the Fibre Channel network elx_mes1307 READ_LA mbox error lt mbxStatus gt state lt hba_state gt DESCRIPTION The driver cannot determine what type of link event occurred DATA None SEVERITY Information LOG LOG_LINK_EVENT verbose ACTION If numerous link events are occurring check the physical connections to the Fibre Channel network May indicate a possible hardware or firmware problem IOCTL Events 1600 1699 elx_mes1601 libdfc ioctl entry DESCRIPTION The entry point for processing an ioctl DATA 1 Ipfc_cmd 2 lpfc_arg1 3 lpfc_arg2 4 lpfc_outsz SEVERITY Information LOG LOG_LIBDFC verbose ACTION None required Driver for Linux Troubleshooting Section Page 69 elx_mes1602 libdfc ioctl exit DESCRIPTION The exit point for processing an ioctl DATA 1 rc 2 lpfc_outsz 3 lpfc_dataout SEVERITY Information LOG LOG_LIBDFC verbose ACTION None required elx_mes1604 libdfc error DESCRIPTION An error occurred in the Ipfcdfc ioctl module DATA 1 error number index SEVERITY Error LOG Always ACTION Reduce the application program s SCSI send request buffer size to less then 320K bytes VPort Eve
104. these errors to Technical Support FARP Events 0600 0699 elx_mes0600 FARP RSP received from DID lt did gt DESCRIPTION A FARP response was received DATA None SEVERITY Information LOG LOG_IP verbose ACTION None required elx_mes0601 FARP REQ received from DID lt did gt DESCRIPTION An unsolicited FARP request was received DATA None SEVERITY Information LOG LOG_IP verbose ACTION None required FCP Traffic History 0700 0799 elx_mes0700 SCSI layer issued LUN reset lt target gt lt LUN gt DESCRIPTION The SCSI layer is requesting the driver to abort I O to a specific LUN DATA 1 ret 2 status 3 result SEVERITY Error LOG Always ACTION Check the state of the target in question Driver for Linux Troubleshooting Section Page 55 elx_mes0702 Issue Target Reset to TGT lt num gt DESCRIPTION The SCSI layer detected that it needs to abort all I O to a specific target This results in an FCP Task Management command to abort the I O in progress DATA 1 rpi 2 flags SEVERITY Information LOG LOG_FCP verbose ACTION Check the state of the target in question elx_mes0703 Issue LUN Reset to TGT lt num gt LUN lt num gt DESCRIPTION The SCSI layer detected that it must abort all I O to a specific device This results in an FCP Task Management command to abort the I O in progress DATA 1 rpi 2 flags SEVERITY Information LOG LOG_FCP verbose ACTION Check the sta
105. ts of patents or other rights of third parties that may result Periodic changes are made to information contained herein although these changes will be incorporated into new editions of this manual Emulex disclaims any undertaking to give notice of such changes Emulex 3333 Susan Street Costa Mesa CA 92626 Driver for Linux User Manual Page ii MIS TAN ATION sacesiinecenascashannadecsassssnascsnncaeacdauanawenadveusceesauauanaweanadsssndeeseiseanawenes 1 Driver INfOFMATON se cscccsctasctetacatatetedetetetetetetatanatadetatatacatetatadetanatanetatenatatedetatenatatatenad 1 Supported Features ccccccccceeeeeeeccceeee eee eeeeeeeccaaeeeeeeeeceeecaaaeeeeeeeeccaaeeeeeeesenee 1 PRETO QUISIOS ssc8iics ctessteesasd Seek shen sesasten usd chen ceed etea cued etea shed chaa chek chetehancteseheseteaetotands 1 For the Ipfc Driver Kit cccceccccccceeceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeneees 1 COMO AUIIN LY oe sx tara soc ents ee cece teat cee ee Bates ee Ba caer ee cee eee 2 Things to Know Before You Download 0 0 0 ieee 2 KMOWMASSUGS cccieteicpeteletesseenstersntnenenehenehanehanehanshanehanehanenanehanesanehagenetmverderdvcs 2 Installing the Driver Kit sorrire 3 Driver Kit Install Script OPtionS ccceeeccecceeeeeeeeeeeeeeeecneeeeeeeeeeeeeetaeeeeeeeeetneee 4 Driver Kit Directory Structure cccccccceeeneeeeeeeeeeeeecneeeeeeeeeeeeeecaeeeeeeeetteesaaaes 4 Installing the Driver on Unsupported
106. tus of the feauthd daemon If it is running it issues a stop and then a start command If the fcauthd daemon is not running nothing happens Driver for Linux Configuration Section Page 27 Authentication Configuration Parameters You can configure each port s authentication parameters using the HBAnyware 3 4 configuration utility Refer to the HBAnyware 3 4 User Manual to learn how Setting Remote and Local Passwords You can configure each port s password using the HBAnyware 3 4 configuration utility Refer to the HBAnyware 3 4 User Manual to learn how Driver for Linux Configuration Section Page 28 Troubleshooting Introduction There are several circumstances in which your system may operate in an unexpected manner The Troubleshooting section explains many of these circumstances and offers one or more workarounds for each situation Unusual Situations and their Resolutions General Situations Table 6 General Driver Situations Situation Resolution FC link fails to come up If an FC link fails to come up verify that an 8 Gb HBA is not attempting to connect to a 1 Gb device Only 2 Gb 4 Gb and 8 Gb devices are supported on 8 Gb HBAs Error states Authentication is enabled but authentication service is not running If you see this message in var log messages and the HBA is in an Error state the fcauthd daemon probably is not running To check if fcauthd is running execute
107. u are prompted as to whether or not to allow users to change management mode after installation Enter the letter y for yes or n for no Utilities Directory Structure After installation the following directories are created on the system Table 2 Utilities Directory Structure Directory Description usr sbin hbanyware HBAnyware files Driver for Linux Installation Section Page 7 Installing the HBAnyware Utility with Web Launch Prerequisites Before installing the HBAnyware utility with Web Launch ensure your systems meet the following requirements The system on which you are installing the Web Launch services package the server requires the following The HTTP server must be configured to handle the JNLP MIME file type The following MIME file type file extension must be added to your server configuration MIME type application x java jnlp file File Extension jnlp The HTTP server must be configured and running The system on which you are running the browser the client requires the following The Java Runtime Environment JRE 5 0 or later must be installed Below are the spe cific requirements e Sun 32 bit JRE 5 0 or later for Intel based systems x86 and IA64 e IBM 64 bit JRE 5 0 or later for PowerPC e Sun 32 bit JRE 5 0 or later x86 64 Refer to the appropriate vendor documentation for detailed instructions about configuring MIME types configuring and starting the HTTP server
108. upport Driver for Linux Troubleshooting Section Page 45 elx_mes0301 READ _SPARAM no buffers DESCRIPTION The driver attempted to issue a READ_SPARAM mailbox command to the HBA but there were no buffers available DATA None SEVERITY Warning LOG LOG_MBOX verbose ACTION This message indicates 1 Kernel virtual memory is depleted Check that the system meets minimum RAM requirements for the Emulex Fibre Channel adapter Try closing other applications to free some memory 2 A possible driver buffer management problem If the problem persists report the error to Technical Support elx_mes0302 REG_LOGIN no buffers DESCRIPTION The driver attempted to issue a REG_LOGIN mailbox command to the HBA but there were no buffers available DATA 1 Did 2 flag SEVERITY Warning LOG LOG_MBOX verbose ACTION This message indicates 1 Kernel virtual memory is depleted Check that the system meets minimum RAM requirements for the Emulex Fibre Channel adapter Try closing other applications to free some memory 2 A possible driver buffer management problem If the problem persists report the error to Technical Support elx_mes0303 Ring lt ringno gt handler portRspPut lt portRspPut gt is bigger then rsp ring lt portR spMax gt DESCRIPTION The port rsp ring put index is larger than the size of the rsp ring DATA None SEVERITY Error LOG Always ACTION This error could indicate a software driver firmware or h