Home

User`s Manual Tobii C-Series C8 C12 C15 CEye

image

Contents

1. Compliance level Electromagnetic environment guidance Portable and mobile RF communications equipment should be used no closer to any part of the C Series device including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Recommended separation distance JP for 150 kHz to 80 MHz d B JP for 80 MHz to 800 MHz 7 d al P for 800 MHz to 2 5 GHz 3 where is the maximum output power rating of the transmitter in watts VV according to the transmitter manufacturer and d is the recommended separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey should be less than the compliance level in each frequency range Interference may occur in the vicinity of equipment marked with the following symbol t NOTE At 80MHz and 800MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflected from structures objects and people 82 Chapter 8 Appendices Tobii C Series User s Manual Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic e
2. Send text e keyboard input In the Send keyboard input list select the keystroke you want to send to an alternative program Send mouse click the Send mouse click list select the desired mouse click left middle or right mouse click e Sendtext In the Send text box type the text you want send to an alternative program Start Program Click Browse the first time you are using this option to find and select a program Chapter 5 Using the Tobii C Series 39 Tobii C Series User s Manual 40 Start Program Click Browse to find and select a program Browse Selected program Program Arguments The next time you click the Start Program option a list of previously selected programs will be displayed You can then directly select a program from the list or click Browse if you want to start a program not in the list Start Program Windows Explorer Click Browse to find and select program or select from the options above Selected program Windows Explorer Program Arguments For the selected program it is possible to add program arguments However this is normally not required If the program should require arguments and you do not know what to enter please contact the company you purchased the software from Volume choose to increase decrease or mute the volume by clicking the preferred option Volume Increase volume Decrea
3. e Wireless Allows the user to either set all radio connections on or off or a specific wireless connection e Touch Screen Allows the user to turn on or off the Touch Screen The available actions are the same for the quick access buttons and Switches To create a shortcut to an action l Open the C Series Hardware Options 38 Chapter 5 Using the Tobii C Series Tobii C Series User s Manual 2 Select Buttons or Switches depending on which one you want to customize 3 Click Set action to view the dialog box where you can select the action you would like the button to perform By selecting one of the actions the options for this action will be revealed below the chosen action Audio Buttons Backlight Select actions for the quick access button A B and C by clicking Set action The buttons are located on the right side of the device Button A Environmental Control No action selected Play sound Setaction Switches If you would like the quick access button to make a sound when pressed select the Play sound check box after having set an action Button A Environmental Control Toggle track status window Play sound Set action Switches 5 13 2 Selecting Actions Send Input choose either to send a keyboard input a mouse click or specified text by clicking the option you want the device button or Switch to perform Send Input saint LE Send mouse click lr e
4. 5 8 Using Bluetooth optional Not applicable for RF Free units The built in Bluetooth enables connection to wireless devices which comply with ordinary Bluetooth standards 5 8 1 Handling Licenses To use Bluetooth communication in the device a license is required To view or enter a license go to the Licenses section in the C Series Hardware Options 5 8 2 Enabling and Disabling Bluetooth Communication You enable and disable Bluetooth communication in the Wireless section in the C Series Hardware Options Environmental Control Switches Temperature Control Touch Screen To enable Bluetooth communication 1 Select the Enable wireless units check box 2 Select the Bluetooth check box 32 Chapter 5 Using the Tobii C Series Tobii C Series User s Manual To disable Bluetooth communication Clear the Bluetooth check box or the Enable wireless units check box for disabling all wireless units If the Bluetooth communication is activated you can see the Bluetooth icon in the Notification area on the desktop I iNodfcation Area 5 8 3 Connecting to a Bluetooth Device When the Bluetooth communication is activated see above you can connect the C Series device to another Bluetooth device To search for available Bluetooth devices and connect to them use the Bluetooth Devices in Windows 7 To access Bluetooth Devices Double click on the Bluetooth
5. Fonctonsity to configure interaction forthe selected profile and optionally fora specife application Calibration Settings nr optionally fora specife appl User Profiles Windows Control Settings System Settings System Information IT Show visible outline around the activated region To adapt the CEye module s interaction follow the steps below Open Tobii Eye Control Options gt Interaction 52 Chapter 6 Tobii CEye Module amp Eye Control Tobii C Series User s Manual Scope 2 Select how the interactions setting should be reflected Click Default settings of the currently selected user profile if you want to apply the new settings to the whole user profile and not only to a particular application Click Application specific settings of the currently selected user profile if you want to apply the new settings to a specific application of a user profile Then select application in the Application drop down list Method 3 Selectthe activation method from the Activation method drop down list There are three methods available each with different activation times Dwell Adjust the dwell time by moving the Dwell time slider e Switch Adjust the minimum time for a click duration and the minimum time between clicks by moving the respective slider Blink Adjust the minimum and maximum duration for a blink by moving the respective slider Visual Feedback 4 Select the symbol for visu
6. Operating system Hard disk drive SD Card Connectors ECU Environmental Control Unit Battery Time Camera Deskstand Mounting Systems Supported Power Supply 8 4 resistive touch Tobii C Series User s Manual Tobii C8 Tobii C8 RF Free Tobii C12 Tobii CI2 RF Free Tobii C15 Tobii CI5 RF Free 12 1 resistivetouch 15 0 resistive touch CCFL backlit CCFL backlit LED backlit 800 x 600 pixels 1024 x 768 pixels 1024 x 768 pixels 9 4 x 7 9 x 1 5 12 3 x 10 4 x 1 8 14 6 x 11 8 x 2 2 23 9x20 1x3 8cm 31 2 26 4 4 6 37 0 30 0 5 7 cm 4 0 lbs 6 5 Ibs 8 8 lbs 1 8 kg 2 9 kg 4 0 kg 2 integrated 2 pairs integrated 2 integrated Intel Core Duo U2500 1 2 GHz 2GB DDR2 Microsoft Windows 7 60GB 1GB 2 x USB 2 0 1 x Mini USB 2 0 Ethernet 1 x RJ45 2 x 1 8 Switch 1 x 1 8 Headphone stereo 1xDC in 2 5 5 5 mm Tira 2 1 6h 5h 5h 640x480 pixels Integrated Optional brackets for Vesa Daessy Rehadapt CJT Powerbox EXM 80 5121 24 V Chapter 8 Appendices 87 Tobii C Series User s Manual Tobii CEye 23 5 in Working distance optimal 60 cm Track Box for Eye Head Movement 15 7 x 11 8 x 79 in Width Height Depth 40 x 30 x 20 cm 11 8 in s Head movement speed optimal 30 cm s Gaze Data rate Variable up to 40 Hz Accuracy gaze estimation 0 8 degrees 12 3 oz Weight 350g 8 5 Appendix E Approved Accessories For information about the latest approved Tobii Ac
7. Voltage lt 5 U 295 76 lt 5 0 295 Mains power quality should be dips short dip in U for 0 5 dip in U for 0 5 that of a typical commercial or interruptions and cycles cycles hospital environment If the voltage variations 40 U 60 dip 40 U 60 dip user of the C Series device on power supply in U for 5 cycles U for 5 cycles requires continued operation input lines 70 U 30 70 U 30 during mains interruptions it is IEC 61000 4 11 dip in U for 25 dip in U for 25 recommended that the C Series cycles cycles device batteries are in place 576 U 295 76 lt 5 0 295 or that the device be powered dip in U for 5 s dip in U for 5 s from an uninterruptable power supply UPS U is at 100 VAC 60 Hz or 230 VAC 50Hz Power frequency Power frequency magnetic fields 50 60 Hz should be at levels characteristic magnetic field of a typical location in IEC 61000 4 8 typical commercial or hospital environment Chapter 8 Appendices 81 Tobii C Series User s Manual Guidance and manufacturer s declaration electromagnetic immunity The C Series device is intended for use in the electromagnetic environment specified below The customer of the user of the C Series device should assure that it is used in such an environment Immunity test Conducted RF IEC 61000 4 6 Radiated RF IEC 61000 4 3 IEC 60601 test level 3 Vrms 150 kHz to 80 MHz 3 Vim 80 MHz to 2 5 GHz
8. fthe background color of the Calibration Result is light red you have achieved a relatively low quality calibration You can improve one or more points individually or recalibrate completely to achieve better eye tracking results e fthe background color of the Calibration Result is light yellow you have achieved a medium quality calibration You might be able achieve better eye tracking results by improving one or more points individually e fthe background color of the Calibration Result is green you have achieved a high quality calibration Be aware that no matter what quality of calibration you have achieved you will be able to select OK or Apply and begin using eye control It is the accuracy and functionality of the eye control that is affected by the quality of the calibration results Try for the best calibration possible 56 Chapter 6 Tobii CEye Module amp Eye Control Tobii C Series User s Manual The closer the lines within the calibration point are to a dot in the center of the circle of the calibration point the better the calibration is of that point You can choose the points to be improved and calibrate only those points again Improve one or more calibration points by Opening Tobii Eye Control Options gt Eye Tracking 2 Under Calibration Result marking the point s you want to improve 3 Clicking Improve Point s and a calibration for the selected point s will start 6 3 5 Removing Calibra
9. 15 seconds is up it will turn yellow Continue holding until the timer clock has counted up to 100 The target will then move to the next corner anticlockwise counterclockwise Chapter 5 Using the Tobii C Series 29 Tobii C Series User s Manual 5 6 Adjusting the Backlight You can adjust the display brightness level by l Opening the C Series Hardware Options gt Backlight 2 Moving the slider to the right to increase the brightness and to the left to decrease it The backlight needs a short while to adjust when changing the brightness There is a sensor on the device which will automatically adjust the screen brightness according to the surrounding light relative to the selected level Backlight Select the display brightness level Using a darker setting will make your battery last longer The backlight needs a brief moment to adjust Buttons to the environment after changing to a new value Environmental Control Switches Q Temperature Control Touch Screen Wireless Safety Licenses System Information Using a darker setting can improve battery life 30 Chapter 5 Using the Tobii C Series Tobii C Series User s Manual 5 6 1 Adjusting the Sound You can configure the built in speakers using the Windows 7 Control Panel gt Hardware and Sound and the C Series Hardware Options Refer to Microsoft s information on how to configure the sound in the Windows 7 Control Panel T
10. 4 Appendix D Technical Specifications Standard Model Screen Screen resolution Dimensions WxHxD Weight Speakers Microphones Processor RAM Operating system Hard disk drive SD Card Connectors WLAN optional Bluetooth optional Mobile Phone GSM optional ECU Environmental Control Unit Battery Time Camera Deskstand Mounting Systems Supported Power Supply Tobii C8 T C84 R1 0A VO Tobii C12 T C12 R1 0A V1 Tobii C15 T C15 R1 0A VO 8 4 resistive touch 12 1 resistivetouch 15 0 resistive touch CCFL backlit CCFL backlit LED backlit 800 x 600 pixels 1024 x 768 pixels 1024 x 768 pixels 9 4 x 7 9 x 1 5 12 3 x 10 4 x 1 8 14 6 x 11 8 x 2 2 23 9x20 1x3 8cm 31 2 26 4 4 6 37 0 30 0 5 7 4 0 lbs 6 5 lbs 8 8 lbs 1 8 kg 2 9 kg 4 0 kg 2 integrated 2 pairs integrated 2 integrated Intel Core Duo U2500 1 2 GHz 2GB DDR2 Microsoft Windows 7 60GB 1GB 2 x USB 2 0 1 x Mini USB 2 0 Ethernet 1 x RJ45 2 x 1 8 Switch 1 x 1 8 Headphone stereo 1xDC in 2 5 5 5 mm IEEE 802 11 b g IEEE 802 11 b g n Class 2 v2 1 EDR Tri band 900 1800 Quad band 850 900 1800 1900 MHz 1900 MHz Tira 2 1 6h 5h 5h 640x480 pixels Integrated Optional brackets for Vesa Daessy Rehadapt CJT Powerbox EXM 80 5121 24 V 86 Chapter 8 Appendices RF Free Model Screen Screen resolution Dimensions WxHxD Weight Speakers Microphones Processor RAM
11. C Series User s Manual 4 2 1 Checking Charge Level Click on the battery icon i in the Notification area to see the remaining charge of the battery which is installed in the device Notification Area You may also at any time check the status of a battery by pressing the indicator button on the face of the battery Five LEDs light emitting diodes will indicate the remaining charge level For example three lit LEDs indicate a 60 remaining charge EE d 0096 Indicator button and LED s When charging the highest capacity LED indicator will be blinking The lowest capacity LED indicator the 20 LED will also blink when the indicator button is pressed if the battery s capacity has dropped below 1076 So don t rely upon the blinking of the 2076 indicator as a guarantee for charging If the batteries have been deeply discharged this can happen by leaving an empty battery inserted in the C Series device without the power adapter connected you may not see any indication of charging when you reconnect the adapter properly to the C Series device or the Table Charger It may take some time even up to 20 minutes before you see an LED indication that any charging is taking place The battery IS being charged during this duration though it is a recovery charge raising the level enough to begin normal charging Chapter 4 Batteries in the Tobii C Series 15 Tobii C Series User s Manual 4
12. Environmental Control section of the C Series Hardware Options Audio Environmental Control mmm Backlight Enable or disable environmental control units To add licenses for Ss 9 unlicensed units go to the Licenses page Buttons e To ECH Switches Temperature Control Touch Screen Wireless Safety Licenses System Information Cancel To enable Tira Chapter 5 Using the Tobii C Series 37 Tobii C Series User s Manual Select the Tira check box To disable Tira Clear the Tira check box 5 13 Creating Shortcuts to Actions You can create shortcuts to tasks called actions by programming the quick access buttons and connected Switches The quick access buttons are located on the right side of the C Series device named A B and C Switches are connected to the Switch connectors Switch 1 Switch 2 3 5 3 5 mm mono 5 13 1 Available Actions This is a short description of each action available to set Send input Allows the user to send input to an alternative program keystroke mouse click or text Start Program Allows the user to start a program e Volume Allows the user to adjust the volume up or down or to set mute on or off e Backlight Allows the user increase or decrease the backlight of the screen e Eye tracking Allows the user to show and hide the track status window calibrate or pause the eye tracking on or off
13. Ka drag and 2 drop or Rs cursor type e movement Check the Custom cursors check box activate custom cursors for Windows Control in Mouse Emulation mode 70 Chapter 6 Tobii CEye Module amp Eye Control Tobii C Series User s Manual 6 4 4 2 Placing the Mouse Emulation Menu The menu can be placed anywhere on the desktop or docked along the edge of the screen You dock the Mouse Emulation Menu by dragging it to the edge of the screen You can also do this by pressing and dragging the Move icon lt gt When the menu is docked you have to look outside the screen to bring up the Mouse Emulation Menu items 6 4 4 3 Clicking with Windows Control in Mouse Emulation Mode Select what type of mouse click you want to perform from the Button drop down list in the Mouse Emulation Menu Q Right click simulates a right mouse click 6 Left click simulates a left mouse click 6 4 4 4 Magnifying with Windows Control in Mouse Emulation Mode To use the magnifier select the magnifier icon in the Mouse Emulation Menu If you want to perform a click with the magnifier Select the magnifier 2 Select the other options as usual The options will now have changed to reflect the magnification state A Right Click Zoom a Left Click Zoom Chapter 6 Tobii CEye Module amp Eye Control 71 Tobii C Series User s Manual 6 4 4 5 Selecting Mouse Emulation Functions You can set different functio
14. Series User s Manual desired position on the screen or icon on it If the selection method is set to Switch in the Gaze Selection Settings Dialog the chosen Task Button will still remain active after executing the Task High Precision Same as Selected but with a higher precision High Precision means that the zoom will progress deeper before the final execution of the Task making the desired portion of the screen bigger and easier to select within Activate this mode by resting your gaze on the Task Button until the color changes according to the image below Normal Track Status Place Cursor Scroll Left Click Double Click Right Click Drag amp Drop Settings Track Status Ci Place Cursor o Scroll Left Click W i Double Click 6 Drag amp Drop Fo Settings Le Selected High Precision Chapter 6 Tobii CEye Module amp Eye Control 63 Tobii C Series User s Manual 6 4 3 2 Task Buttons Place Cursor Task that places the mouse cursor ona desired point position Used for mouse over functions etc this is not a click Gaze Scroll Task that if performed on a scrollable window enables a gaze controlled way to scroll the page Select the Task Look at any scrollable area and hold your gaze the Gaze Scroll icon will appear where you looked Look above the icon to scroll up Look below the icon to scroll down Look back at the Gaze
15. a factory image stored on the disk If you need to restore the device back to its original state this can be done by using our OEM Factory Restore Application Please note that this will delete any personal data or software installed after the device was delivered The device will be reset to the exact same image it had when it was shipped from Tobii To restore the factory settings for your C Series device performe the following procedure l Backup your personal data such as documents and Tobii Communicator settings etc Shut down the device Connect a keyboard Start up device again Press and hold F8 during startup Select Repair your computer Select the keyboard layout language you want Select Tobii User and enter Tobii as password Case Sensistive Select OEM Factory Restore Application Select Restore Now accept the agreements and confirm the restore again with Yes TO The factory restore process will now start This will take about 30 40 minutes After the restore process is finished the device will be reset to its original image If you have ordered additional licenses after you ordered the device these will have to be input again Any licenses originally ordered together with the device will automatically be activated Also if the device was ordered without a CEye module Tobii Eye Control Suite will have to be reinstalled if the device is intended to be used with a CE
16. and ready to use Should a reinstallation become necessary at any stage a setup file and discs are included The product number for Windows can be found on the back of the C Series device if there should be a need to reinstall Windows 3 4 Configuring the Device Use the preinstalled C Series Hardware Options to configure the hardware functions on the device You can access C Series Hardware Options in one of the following ways Goto Start menu gt Control Panel sarme rrr 2 Double click C Series Hardware Options 9 if the Control Panel is in Classic View If the Control Panel is in Control Panel Home view click Additional Options gt C series Hardware Options or Double click the C Series Hardware Options shortcut on the desktop 3 or 3 Start menu gt All Programs gt Tobii gt C Series Hardware Options 4 Click C Series Hardware Options 9 In the list to the left select which hardware configuration you want to change In the list to the right the different settings will be revealed The changes are instantly executed If you want to cancel the changes click Cancel Please note that anywhere you see this icon an information box is displayed when you briefly rest the mouse pointer on the icon or by touching the icon on the screen Chapter 3 Overview of the Tobii C8 C12 and C15 13 Tobii C Series User s Manual Batteries in the Tobii C Series 4 1 Batteries The C Ser
17. button Right click hold finger on icon for touch screen right clicking the Tobii Eye Control Options icon in the Notification area and select Start Calibration i Rhin 6 3 2 Interrupting Calibration Interrupt the calibration in one of the following ways Press Esc Left click on the screen with the mouse Touch the screen 6 3 3 Customizing Active Eye Select the eye you want to be tracked by the eye tracker by Opening Tobii Eye Control Options gt Eye Tracking 2 Selecting active eye from the Active Eye drop down list Note This is done after a calibration is finished Active Eye Selects the eye that will be tracked by the eye tracker Both d Chapter 6 Tobii CEye Module amp Eye Control 55 Tobii C Series User s Manual 6 3 4 Improving Calibration Point s il c Control Options Connected Current User Profile Calibration Settings us B ie Interaction Calibrate User Profiles Perform a calibration based on the curent calibration settings Windows Control Settings epes Celeron reas System Settings System Information Calibration Result Low quality catrtion 1m completely to achieve bel Selects the eye that wil be wacked by the eye wacker Ia 7 Me Eg After calibration you may want to improve one or more points There is a color scheme used that will help you to understand the quality of your calibration e
18. corner of anything that is run in Windows Full Screen mode To exit Windows Full Screen mode Rest your Gaze for a few moments on the X in the top left corner of the screen The X will be highlighted in red while it is being activated e Windows Full Screen mode will then be exited Note that the X might be difficult to see sometimes depending on the colors of what is being viewed in Windows Full Screen mode It always starts out large and shrinks to draw your attention to it 6 4 4 Mouse Emulation The Mouse Emulation mode makes it possible for the user to emulate and control a standard PC mouse pointer on the screen 68 Chapter 6 Tobii CEye Module amp Eye Control Tobii C Series User s Manual 6 4 4 1 Customizing Windows Control for Mouse Emulation Current User Profile Eye Tracking Windows Control Settings Functionality to configure te tehavior of he Windows Control for the e Ge prom for the selected proi Interaction IE auto siart Conta ot boot System Settings Windows Control Type System Information Magnifier Sze 10 pe Zoom Factor Mouse control speed Customize the mouse control speed by moving the Mouse control speed slider Move the slider to the right to increase the speed and to the left to decrease it Magnifier size and zoom Customize the size of the magnifier by moving the Magnifier Size slider Move the slider to the right to increase the s
19. generate synthesized computer voice or digitized recorded voice speech for face to face communication A user also has the option of communication through e mail text messages and chat With the Tobii C Series users also have the freedom and flexibility to write and edit documents surf the Internet play music and games control a TV DVD and other household appliances via IR remote control and even plan and manage their time making independence easy The C Series devices are available both as a dedicated Speech Generating Devices with communications software access only or as open devices with access to the regular Windows environment The C Series device is not intended as sole communication means for a user but as a complementary communication solution Low tech and no tech Assistive and Alternative Communication AAC solutions used as additional methods are recommended as best practice for any person utilizing a high tech AAC device 6 Chapter 1 Introduction Tobii C Series User s Manual 1 2 Package Contents The items below are included with your C Series package e A Tobii C8 Tobii CI2 or a Tobii CI5 Tworechargeable Lithium lon LiPo batteries ADC power adapter charger including four different plugs for different regions e A carrying strap extendable to shoulder strap for the C8 and CI2 Manual this document AGetting Started Guide Three pairs of side covers the black covers a
20. of this manual and in the 8 4 Appendix D Technical Specifications section including but not limited to the Medical Device Standard Class 1 Type B Nevertheless in order to ensure safe operation of your Tobii C series device there are a few safety warnings to bear in mind Do not place the device on your lap a pillow or any other soft material when it is powered on since the material can block the fan and cause the device to overheat A The C Series device contains Lithium lon batteries These batteries have a storage temperature range of between 20 C and 40 C within 3 month Only charge the batteries in the temperature range of between 0 C and 40 C Avoid exposing the batteries to fire or to temperatures above 50 C 122 F These conditions may cause a battery to malfunction generate heat ignite or explode Be aware that it is possible in a worst case scenario for temperatures to reach greater than those stated above in for example the trunk of a car on a hot day So storing the device with batteries installed in a hot car trunk could conceivably lead to a malfunction Do not disassemble or harm the battery Pay attention to the environmental laws and regulations which apply in your area when disposing of batteries A For safe operation of the C Series device use only charger batteries and accessories approved by Tobii Technology A Do not open modify the metal casing of the C Series device o
21. or something due to falling neither Tobii Technology nor any of its representatives will be responsible or liable for any damages or injuries which may arise The mounting of devices from the C Series is done entirely at the user s own risk 2 3 Emergency Warning Do not rely on the device for emergency calls or banking transactions We recommend having multiple ways to communicate in emergency situations Banking transactions should only be carried out with a system recommended by and approved according to the standards of your bank 2 4 Infrared Warning When activated the Tobii CEye emits pulsed infrared IR light Certain medical devices are susceptible to disturbance by IR light and or radiation Do not use the CEye when in the vicinity of such susceptible medical devices as their accuracy or proper functionality could be inhibited Chapter 2 Safety 9 Tobii C Series User s Manual 10 2 5 Epilepsy Warning Some people with Photosensitive Epilepsy are susceptible to epileptic seizures or loss of consciousness when exposed to certain flashing lights or light patterns in everyday life This may happen even if the person has no medical history of epilepsy or has never had any epileptic seizures A person with Photosensitive Epilepsy would also be likely to have problems with TV screens some arcade games and flickering fluorescent bulbs Such people may have a seizure while watching certain images or patterns on a monitor or ev
22. 3 Inserting and Releasing the Batteries For safety reasons the C Series device is delivered without the batteries inserted The batteries are delivered only partially charged The C Series device can be used right away It is nevertheless recommended that the batteries are charged for at least two hours before taking the device in use To insert the batteries Place the C Series device face down on surface 2 Insert a battery in the battery compartment 3 Press the battery down until it locks in place You should hear a click that confirms that the battery is in a locked position 16 Chapter 4 Batteries in the Tobii C Series Tobii C Series User s Manual To release the batteries Place the C Series device face down on flat surface 2 Use both hands to slide the rubber feet apart on the battery You will hear a click as they are released 3 Lift the battery up and out of the device Chapter 4 Batteries in the Tobii C Series 17 Tobii C Series User s Manual Using the Tobii C Series 5 1 Starting the Device Start the device in one of the following ways e Press the power button on the right side of the device 0 Activate a configured Switch see Configuring a Switch to Power On or Off When you have started the device the LEDs on both sides of the display will first shine blue then turn green at the start up of the display 5 1 1 Password Information The C Series device is con
23. 3 Restoring the Factory Settings of a C Series Device Tobii CEye Module amp Eye Control 6 1 Installing the Tobii CEye Module 6 1 1 Mounting the CEye Module to the Tobii C12 or C15 6 1 2 Required Software 6 1 3 Installation of Eye Control Software from USB Stick 6 2 Using the Tobii CEye Module 6 2 1 Positioning 6 2 2 Track Status Viewer 6 2 3 Track Box 25 26 27 27 28 28 30 81 32 32 32 32 33 33 33 33 34 34 35 36 36 36 37 37 38 38 39 42 43 43 43 43 44 45 45 45 46 47 48 48 48 49 6 2 4 Accessing the Tobii Eye Control Options 6 2 5 Creating a New Profile 6 2 6 Selecting Current User Profile 6 2 7 Deleting a Profile 6 2 8 Customizing the Interaction 6 2 9 Showing Track Status 6 3 Calibration 6 3 1 Starting Calibration 6 3 2 Interrupting Calibration 6 3 3 Customizing Active Eye 6 3 4 Improving Calibration Point s 6 3 5 Removing Calibration Point s 6 3 6 Customizing the Calibration 6 3 7 Customizing the Calibration Area 6 4 Windows Control 6 4 1 Starting and Disabling Windows Control 6 4 2 Windows Control Type 6 4 3 Gaze Selection 6 4 4 Mouse Emulation Product Care 71 Temperature amp Humidity 7 1 1 General Use 7 1 2 Transportation and Storage 7 2 Changing the Side Covers 7 3 Cleaning 7 3 1 Cleaning of the Speaker Mesh 7 4 Placement 7 5 Transporting the C Series Device 7 6 Disposing of the Batteries 7 7 Disposing of the C Series Device Appendices 8 1 Appe
24. 5 W at rated load conditions Therefore no limits are applicable Voltage Fluctuations flicker Not Applicable The product has an active power of emissions IEC 61000 3 3 Ps75 W at rated load conditions Therefore it is not likely to produce voltage fluctuations or flicker above the limit values A The C Series device should not be used adjacent to or stacked with other equipment 80 Chapter 8 Appendices Tobii C Series User s Manual Guidance and manufacturer s declaration electromagnetic immunity The C Series device is intended for use in the electromagnetic environment specified below The customer or the user of the C series device should assure that it is used in such an environment IMMUNITY IEC 60601 test Compliance Electromagnetic test level level environment guidance Electrostatic 6 kV contact Floors should be wood discharge ESD X 8kV air 6 kV contact concrete or ceramic tile If floors are covered with IEC 61000 4 2 8kV air synthetic material the relative humidity should be at least 30 Electrical fast 2 kV for power Mains power quality should be transient burst supply lines 2 kV for power that of a typical commercial or IEC 61000 4 4 kV for input hospital environment supply lines output lines kV for input output lines Surge kV line to line Mains power quality should be IEC 61000 4 5 1kVline to line that ofa typical commercial or hospital environment
25. C Series device comes with a 1GB SD card installed The purpose of this card is to backup personal settings and data In the case of fatal damage to the C Series device Tobii Technology can remove the SD card and have it inserted into a new device for quick and easy retrieval and restoration of personal data and settings 5 16 2 Restoring Backup Files by the User The backup files are placed in the directory Q Backup lt date gt The backup process which runs as user Tobii TaskManager executes once week every Sunday at 15 00 and the three latest backups are saved If your C series device is not up and running at this time the backup will not be performed The process backs up files for all users If the backup drive does not have enough space some files will not be backed up Image files have the lowest priority backed up last The largest file size for the backup of individual files is 100 MB files larger than this will be excluded To restore backup files copy the folders in the directory Q Backup lt date gt to the drive Copies of these backup files can be saved anywhere you wish to an external hard drive for example or to a USB stick Copy the folders in the directory Q Backup lt date gt to any external directory or drive of your choosing aN Chapter 5 Using the Tobii C Series Tobii C Series User s Manual 5 16 3 Restoring the Factory Settings of a C Series Device Every C Series device has
26. Selection Taskbar or outside of the screen to end scrolling a Left Click Task that performs a single left click Double Click Task that performs a double left click BR Right Click Task that performs a single right click 64 Chapter 6 Tobii CEye Module amp Eye Control Tobii C Series User s Manual Task Button action Description Gaze Drag amp Drop Settings 6 4 3 3 Selection Methods Task that performs two clicks where the first one represent the starting position for the drag and the second the drop position to move objects or select areas Select the Task Look at the object you want to move or the starting point for the area selection Execute the Gaze Selection first click by Switch or Gaze Look immediately at the drop position for the object or end point for the area selection Execute the second click by Switch or Gaze Task that opens the Settings Dialog There are two methods to execute the chosen Task The method of choice is set from within the Gaze Selection Settings Dialog Before executing a selection you must always select a Task from the Taskbar to execute Gaze at your chosen task until it is highlighted as Selected or High Precision e Gaze To execute the chosen Task rest your gaze at the desired portion of the screen or icon on the screen where you want to execute the Task An automatic zoom function is enabled ending in the selection of the icon or executio
27. Such access points are generally recognized by having two antennas on the router device Using an antivirus program is strongly recommended 5 10 Using the Camera The built in camera allows you to take snapshots of items in front of the C Series device On the Tobii C8 the camera is located on the top of the device 34 Chapter 5 Using the Tobii C Series Tobii C Series User s Manual On the Tobii C12 and Tobii C15 it is located on the back of the device Refer to Tobii Communicator or alternative communication software manuals for camera function utilization 5 11 Using the Mobile Phone optional Not applicable for RF Free units To use the built in Mobile phone communication feature you need a valid SIM card from a network operator in your area The SIM card should be installed beneath the SIM card cover on the back of the C Series device The Mobile phone feature can be used to Send and receive text messages SMS and multimedia message MMS Chapter 5 Using the Tobii C Series 35 Tobii C Series User s Manual Make telephone calls through synthetic voice e Answer telephone calls through synthetic voice 5 11 1 Handling Licenses To be able to use Mobile phone communication a license is required To view or enter a license go to the Licenses section in the C Series Hardware Options 5 11 2 Enabling and Disabling the Mobile Phone You can enable and disable Mobil
28. Tobii C Series User s Manual User s Manual Tobii C Series cs 09 COP tobii Celebrating Communication Tobii C Series User s Manual Content subject to change without notice Please check Tobii web site www tobii com for updated versions of this manual Manual Version 2 7 1 05 2012 All rights reserved Tobii Technology AB The information contained in this document is proprietary to Tobii Technology Any reproduction in part or whole without prior written authoriztion by Tobii Technology is prohibited US Patent 7 572 008 applies to Tobii CEye Tobii manual Cseries V2 7 24052012 UsEng Contents Introduction 11 Intended Use 1 2 Package Contents 1 3 Customer Support 1 4 Warranty Safety 2 1 Avoiding Hearing Damage 2 2 Mounting Warning 2 3 Emergency Warning 2 4 Infrared Warning 2 5 Epilepsy Warning 2 6 Child Safety Overview of the Tobii C8 C12 and C15 3 1 Key Features 3 2 Product Layout 3 2 1 The Tobii C8 Tobii C12 and Tobii C15 3 2 2 Ports Sensors and Device Buttons 3 3 Preinstalled Software 3 4 Configuring the Device Batteries in the Tobii C Series 4 1 Batteries 4 1 1 Hot Swappable 4 2 Charging 4 2 1 Checking Charge Level 4 3 Inserting and Releasing the Batteries Using the Tobii C Series 5 1 Starting the Device 5 1 1 Password Information 5 1 2 C Series Welcome Guide 5 1 3 C Series Welcome Center 5 1 4 C Series Update Notifier 5 2 Shutting Dow
29. Windows computer with Eye Control and Gaze Interaction 6 4 1 Starting and Disabling Windows Control To start the Windows Control right click on the Tobii Eye Control Options icon in the Notification area and select Enable Windows Control i Area Or Select the Tobii Windows Control shortcut icon ra from your desktop This will immediately start Windows Control To disable Windows Control right click on the Tobii Eye Control Options icon in the Notification area and select Disable Windows Control You can also start the Windows Control from Tobii Communicator or alternative communication software which has implemented the functions provided by the Tobii Eye Control SDK Auto start Open Tobii Eye Control Options gt Windows Control Settings e Check the Auto start windows control at boot check box if you want Windows Control to auto start when the Tobii Eye Control Suite starts 6 4 2 Windows Control Type Windows Control can be used in two different modes Gaze Selection Mouse Emulation Chapter 6 Tobii CEye Module amp Eye Control 61 Tobii C Series User s Manual To select which type of Windows Control you wish to use and to customize Windows Control Open Tobii Eye Control Options gt Windows Control Settings Select your prefered type of Windows Control under Windows Control Type 6 4 3 Gaze Selection The Gaze Selection mode of Windows Control makes it poss
30. afety text Please read this thoroughly 3 Select the I have read and understand the safety details and want to enable the speaker functionality check box to confirm that you have read and understood the safety text 4 Click Apply or OK to save Chapter 5 Using the Tobii C Series 25 Tobii C Series User s Manual 26 5 4 2 Temperature Control Safety Before you can set the device usage in C Series Hardware Options gt Temperature Control you need to confirm the Temperature control safety details To confirm Open the C Series Hardware Options gt Safety 2 Click on the Temperature control safety details text A new dialog opens and displays the safety text Please read this thoroughly 3 Select the have read and understand the safety details and want to enable the temperature control functionality check box to confirm that you have read and understood the safety text 4 Click Apply or to save You can use the device in a portable or mounted mode Your choice will affect the maximum allowed device temperature and the fan speed While having the device mounted it is allowed to run at a higher temperature Specifying device usage mode takes place outside of the Safety settings but within C Series Hardware Options To specify device usage Open the C Series Hardware Options gt Temperature Control 2 Click on preferred option below Device usage Important If the device is gets overheated the LEDs o
31. al 2 Select calibration background by clicking the background color button and select the desired color 3 Specify the number of points you want to calibrate with two five or nine from the Calibration points drop down list The higher number of points the more accurate the calibration 4 Select if you want to have sound feedback or not from the Sound feedback drop down list 58 Chapter 6 Tobii CEye Module amp Eye Control Tobii C Series User s Manual Stimulus 5 Select the stimulus type from the Stimulus type drop down list There are three types available each with different customizing options Dot Select color of the dot by clicking the Stimulus color button Select size of the dot by selecting from the Stimulus size drop down list Select speed of the dot by selecting from the Stimulus speed drop down list Image Select primary stimulus by clicking Browse and selecting an image Select secondary stimulus by clicking Browse and selecting an image Select size of the image by selecting from the Stimulus size drop down list Select speed of the image by selecting from the Stimulus speed drop down list Video Select primary stimulus by clicking Browse and selecting a video Select secondary stimulus by clicking Browse and selecting a video Select size of the video by selecting from the Stimulus size drop down list Select speed of the video by selecting from t
32. al feedback from the Dwell feedback type drop down list 5 Select the color of the feedback symbol in the Feedback color drop down list 6 Specify the dot size and opacity of the feedback symbol by moving the respective slider 7 Selectthe Show visible outline around the activated region checkbox to see a dashed line around the activated area in all instances of eye control selection 8 Select Simulate activation if you want to see how the activation method will appear on the screen The example is shown above the Simulate activation button Chapter 6 Tobii CEye Module amp Eye Control 53 Tobii C Series User s Manual 6 2 9 Showing Track Status The track status viewer is a window dialog where you can verify that the eye tracker recognizes your eyes and that you are well positioned in front of the device Open the track status viewer in one of the following ways e Open Tobii Eye Control Options gt Eye Tracking and select the Track status button Right click hold finger on icon for touch screen right clicking on the Tobii Eye Control Options icon in the Notification area and select Show track status Notification Area Tobii CEye Module amp Eye Control Tobii C Series User s Manual 6 3 Calibration 6 3 1 Starting Calibration The calibration can be started in one of the following ways Open Tobii Eye Control Options gt Eye Tracking and then click the Start Calibration
33. arefully with a water and dish soap mixture using a misting spray bottle Wipe the mesh clean If excess moisture gets into the speaker housing make sure that it drains through the drainage holes see illustration in the back of the device c8 C12 7 4 Placement Only use the arms and stands specified by the supplier and make sure that they are mounted and fastened correctly according to the instructions Do not place the device on unstable and uneven surfaces Do not cover the ventilation opening on the back of the device with the fan underneath If this opening is covered built up heat may cause failure and be a possible fire hazard Chapter 7 Product Care Tobii C Series User s Manual 7 5 Transporting the C Series Device Disconnect all the cables and either hold the device with both hands while carrying it or use the included carrying strap shoulder strap the carrying strap shoulder strap is not included for the C15 When you transport the device for repair shipment or traveling use the original casing and packaging materials If you have attached a CEye to a CI2 or 5 device do not carry the connected devices by solely gripping the CEye The CEye attachment points may not hold the weight of the C12 or CIS and the devices could break apart causing permanent damage to both and causing the CI2 or CIS to fall 7 6 Disposing of the Batteries Do not dispose o
34. ce down on a flat surface with the side cover you wish to remove facing away from you 4 Take a firm grip on the top and bottom of the device and push the 74 Chapter 7 Product Care Tobii C Series User s Manual two protruding plastic tabs away from you with your thumbs With some pressure the tabs should release and the side cover should come off CH reapply the side covers Place the C Series device face down a flat surface with the side cover you wish to apply facing away from you 2 Place the plastic tabs in their slots on the device 3 Press the side cover onto the side of the device You should hear a click when it has fastened O When reapplying the side cover to the side of the device with the power button be sure that the power button and other buttons makes it s way through the hole in the side cover and is not stuck under it Otherwise the device might not start as the power button may be registered as pressed 7 3 Cleaning Before cleaning the C Series device shut it down unplug all cables and remove the batteries Use a soft slightly damp lint free cloth Avoid getting moisture in openings on the device Don t use window cleaners household cleaners aerosol sprays solvents alcohol ammonia or abrasives to clean the device Chapter 7 Product Care 75 Tobii C Series User s Manual 76 7 3 1 Cleaning of the Speaker Mesh Spray the speaker mesh c
35. cessories please visit the www tobii com website or contact your local Tobii reseller 88 Chapter 8 Appendices tobii www tobii com SWEDEN GERMANY USA JAPAN Phone 46 8 522 950 20 Phone 49 69 24 75 03 4 28 Toll Free 1 800 793 9227 Phone 81 3 5793 3316 Phone 1 781 461 8200 support tobii com support tobii com techsupport tobiiATI com support jp tobii com Support hours 8 am 6 pm Support hours 8 am 6 pm Between July August 9am 5pm Between July August 9am 5pm Support hours 9 am 9 pm Support hours 9 am 5 30 pm Central European Time GMT 1 Central European Time GMT 1 US Eastern Starndard Time GMT 6 Standard Time GMT 9
36. ch screen The Tobii C8 has 8 4 screen with an 800x600 pixel resolution The Tobii C12 has a 12 1 screen with 1024 x 768 pixel resolution The Tobii 5 has a 15 0 screen with a 1024 x 768 pixel resolution 3 2 1 The Tobii C8 Tobii C12 and Tobii C15 1 m E 1 bett 1 lo INI Mi eus i Chapter 3 Overview of the Tobii C8 C12 and C15 11 Tobii C Series User s Manual 3 2 2 Ports Sensors and Device Buttons Speakers Tira 2 1 Camera IR Environmental Control Camera Camera C8 C12 amp C15 C8 C12 amp C15 SSS SS FAA Power button Tt a M i A B and C quick access buttons USB 2 0 O i d H 35 gt NP 5 mm Ambient Light Microphones headphone port Sensor C8 12 amp C15 Carrying i Extensions Port Attachment C8 amp C12 Ethernet USB 2 0 Mini USB 2 0 Switch 1 Switch 2 Power 100 Mbit s 3 5 mm mono 3 5 mm mono Never force a connector into a port If the connector and port do not join with reasonable ease they probably do not match Make sure that the connector matches the port and that you have positioned the connector correctly in relation to the port 12 Chapter 3 Overview of the Tobii C8 C12 and C15 Tobii C Series User s Manual 3 3 Preinstalled Software The C Series device is delivered with all preordered and required software installed
37. clean Windows shut down and is thus not recommended unless completely necessary Chapter 5 Using the Tobii C Series 23 Tobii C Series User s Manual 5 3 Configuring a Switch to Power On or Off 5 3 1 Configuring a Switch to Power On To configure a connected Switch to power on the device Open the C Series Hardware Options gt Switches 2 Select the Enable switch X to power on device check box To disable click to clear the Enable switch X to power on device check box Audio Switches use Select actions for the switches by clicking Set action You can also gt 9 enable the switches to act as power off button Buttons Switch 1 Environmental Control Eire No action selected Play sound Temperature Control E Enable switch 1 to act as power on button Touch Screen Enable switch 1 to act as power off button Wireless Switch 2 Dey Naina FT Enable switch 2 to act as power on button Licenses Enable switch 2 to act as power off button System Information 5 3 2 Configuring a Switch to Power Off To configure a connected Switch to power off the device Open the C Series Hardware Options gt Switches 2 Selectthe Enable switch X to power off device check box To disable click to clear the Enable switch X to power off device check box 24 Chapter 5 Using the Tobii C Series Tobii C Series User s Manual 5 4 Satety Set
38. d the updates to your Device and continue to Step Two e Step Two Click the Install button to install the chosen updates on your device and proceed to Step Three Step Three informs you that your system has been updated click the Done button to close the Update Notifier If you choose not to Enable automatic updates you can still check for updates for your Tobii software and update them manually using the C Series Update Notifier To open and activate the C Series Update Notifier manually this opens the Step One window shown above and starts the same automatic update process Chapter 5 Using the Tobii C Series Tobii C Series User s Manual Navigate in Windows from your desktop to Start Menu gt All Programs gt Tobii gt C Series Update Notifier and click on the C Series Update Notifier icon 2 5 2 Shutting Down the Device The device should be shut down using one of the following ways e Usethe start menu in Windows recommended when possible Pressa configured Switch for two to seven seconds Please note that pressing the Switch for more than 7 seconds will shut down the device immediately disregarding any unsaved changes Should you be unable to shut the device down using either of the above you can hold the power button on the right side of the device down for five seconds The device will consequently shut down immediately without waiting for open applications to close This is not considered a
39. de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lectrique subi m me si le brouillage est susceptible d en compromettre le fonctionnement This device has been tested to the safety requirements for exposure to radio waves SAR in RSS 102 to the General Public Uncontrolled Environment limits 1 6VV Kg The highest SAR value for the C8 device is 1 025 W kg The highest SAR value for the CI2 device is 0 107 W kg The highest SAR value for the 5 device is 0 16 W kg This device can be operated safely with a minimum distance between the equipment and the user s body Ce dispositif a t test aux exigences de s curit pour l exposition aux ondes radio SAR dans le CNR 102 le grand public environnement non contr l des limites 1 6 La valeur maximale mesur e est de SAR pour le C8 dispositif est 1 025 W kg La valeur maximale mesur e est de SAR pour le 2 dispositif est 0 107 W kg La valeur maximale mesur e Chapter 8 Appendices Tobii C Series User s Manual est de SAR pour le 5 dispositif est 0 16 W kg Ce dispositif peut tre exploit en toute s curit avec un Ocm distance minimale entre le mat riel et les corps de l utilisateur This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme la norme NMB 003 du Canada Chapter 8 Appendices 8 Tobii C Series User s Manual 8
40. e phone communication in the Wireless section in the C Series Hardware Options Enonmental Conio 7 Enable wireless units Switches Temperature Control Touch Screen To enable Mobile phone communication 1 Select the Enable wireless units check box 2 Select the Mobile Phone check box To disable Mobile phone communication Clear the Mobile Phone check box or clear the Enable wireless units check box for disabling all wireless units The SIM card must not have a security code enabled to be used with a C Series device 5 12 Using Environmental Control optional C Series device includes an environmental control unit Tira 2 The Tira is a programmable infrared device that can be used to control equipment with IR remote controllers such as TV sets or DVDs Refer to Tobii Communicator or alternative communication software manuals on how to connect configure and use IR remote controls Chapter 5 Using the Tobii C Series Tobii C Series User s Manual Tira 2 1 IR Environmental Control If the device you are trying to control is not responding try tilting the C Series device up or down slightly to change angle at which the IR signal is being sent 5 12 1 Handling Licenses To use the Tira a license is required To view or enter a license go to the Licenses section in the C Series Hardware Options 5 12 2 Enabling and Disabling Tira You can enable and disable Tira in the
41. ed on then l Insert the included USB stick in one of the two USB ports on the C Series marked with the USB icon lt lt AutoPlay window opens automatically labeled with the name of the USB manufacturer and the drive KINGSTON D 2 Double click on the Open folder to view files folder 3 Double click on the Startup icon to start the Tobii Eye Control Suite installation process Be aware that after double clicking the icon may take up to a minute or so before the Tobii Eye Control Suite window will open Though nothing appears to be happening during this time drivers are being automatically installed 4 Tobii Eye Control Suite window will open Read the installation information and follow the instructions click Next etc After installation is complete click Close 5 Close the KINGSTON D drive window 6 Remove the USB stick The required software is now installed onto your C Series device To activate the software once your CEye module is physically attached Open Tobii Communicator or your alternative communications software and follow the instructions provided in the respective manuals for enabling and calibrating eye control To enable eye control in the Windows environment Windows Control launch Tobii Eye Control Options using the following pathway e Start All Programs gt Tobii gt Tobii Eye Control Suite gt Tobii Eye Control Options See Accessing the Tob
42. egular basis or manually at a time of your choosing and assists you in installing the updates If you have chosen to Enable automatic updates in either the C Series Welcome Guide or later in the C Series Welcome Center the Update Notifier will actively search Tobii s sites for version Updates of your software 6 To keep your C Series Device running properly it is highly recommended that you update your Tobii Software on a regular basis and it is therefore highly recommended that you enable automatic updates If an update is found the following Update Notifier window will pop up Chapter 5 Using the Tobii C Series 21 Tobii C Series User s Manual 22 These are the available updates We strongly recommend you to download and install these updates Click Download to begin downloading files C Series Update Notifier New version 1 0 1 0 Current version 1 0 0 0 Cancel Download The update or updates available will show themselves in the Step One window of Update Notifier as large button with a green check mark on the right side You will also be able to see the version number of the software that you currently have and the version number of the update If you choose not to download one or more of the available updates you can click on the button of the update you do not want and the check mark will turn into a red X mark Proceed in the following way Click the Download button to downloa
43. en when exposed to the light sources of an eye tracker It is estimated that about 3 5 of people with epilepsy have this type of Photosensitive Epilepsy Many people with Photosensitive Epilepsy experience an aura or feel odd sensations before the seizure occurs If you feel odd during use move your eyes away from the eye tracker 2 6 Child Safety The C Series are advanced computer systems and electronic devices As such they are composed of numerous separate assembled parts In the hands of a child certain of these parts have the possibility of being separated from the device possibly constituting a choking hazard or another danger to the child Young children should not have access to or the use of the device without parental or guardian supervision Chapter 2 Safety Tobii C Series User s Manual Overview of the Tobii C8 C12 and C15 3 1 Key Features The C Series has several built in features Some of these come standard and some can be ordered as additional features Standard features Camera microphones and speakers Additional features ECU Environmental Control Unit Bluetooth Mobile phone and WLAN Wireless Local Area Network The additional features can be purchased with the initial order or as an additional license after delivery To order a license please contact Tobii Customer Service your reseller or your sales representative 3 2 Product Layout A C Series device has a color TFT display with a tou
44. f the batteries in general household or office waste Follow your local regulations for the disposal of batteries 7 7 Disposing of the C Series Device Do not dispose of the C Series Device in general household or office waste Follow your local regulations for the disposal of electrical and electronic equipment Chapter 7 Product Care J Tobii C Series User s Manual Appendices 8 1 Appendix A Training Resources Tobii offers a range of training resources for the C Series products and related communication products You can find them on the Tobii website www tobii com including Getting Started Guides webinars and Quick guides The C Series Getting Started Guide is delivered with and stored on the device 8 2 Appendix B CEye Software License The CEye module contains open source software Please refer to the attached license document for terms and conditions 8 3 Appendix C Compliance Information 8 3 1 FCC Statment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation 4 Modifications not expressly approved by Tobii Technology could void the user s authority to operate the equipment under FCC rules This equipment has been tested and found to comply with the limits for a Class B digital de
45. figured to start up using the operating system present without a password Though unusual there are situations in which the password window could plausibly pop up for example when creating a new user in the operating system when returning from the operating system s sleep mode or when downloading software updates from the internet Be aware that creating a new user and downloading updates from the internet could possibly compromise the system and software settings of the operating system that have been set and installed at Tobii Technology Should the password window pop up requiring a password the default Chapter 5 Using the Tobii C Series Tobii C Series User s Manual password on all C Series devices is Tobii case sensitive In order to type in the password an external USB keyboard is required not included If you decide to change the password be sure to write it down in a safe place for later use Suggested place to keep new password Without the operating system s access password Tobii Support may be unable to assist you with any future difficulties 5 1 2 C Series Welcome Guide When you start your C Series Device for the first time you will be greeted by the C Series Welcome Guide The guide is a setup wizard that will walk you through four steps that will help you make the most of your device Follow the instructions and click on Next to get to the next page of the Guide Congratulations
46. g licenses the C Series Hardware Options gt Licenses Audio Licenses View current licenses or add new licenses for unlicensed units Backlight Buttons Environmental Control To add a new license you need a valid license key Switches Temperature Control licenses Touch Screen WLAN 12345 67890 Bluetooth Not licensed Wireless Mobile phone ABCDE FGHII 12345 67890 Safety Tire 12345 67890 ABCDE FGHU System Information To license l Click Add License s Buttons Eege To add a new license you need valid license key Switches 2 Inthe Enter license box type the new license and then click Add Environmental Control To add a new license you need a valid license key Switches Enter license S For typing the license use either a connected keyboard or the on screen keyboard by clicking this button 21 42 Chapter 5 Using the Tobii C Series Tobii C Series User s Manual 5 15 System Information To view the version and model of the device Open the C Series Hardware Options 2 Select System Information Please have this information available if you have problems with the device and need to contact Customer Support By clicking Copy all information you can paste the information into a document such as Notepad or WordPad or directly into an e mail 5 16 Performing Backup and Restore 5 16 1 User Profile Card The
47. he Stimulus speed drop down list Check the Animate stimuli check box if you want the stimuli to be animated If you want to control the calibration i e decide when to move the calibration stimuli with a keyboard check the Keyboard step through check box Chapter 6 Tobii CEye Module amp Eye Control 59 Tobii C Series User s Manual For Keyboard step through use the S key to step to move the calibration stimuli and the Esc key the Left mouse button or touching the touch screen to interrupt calibration When using Image or Video calibration use the T key to toggle between primary and secondary stimulus images 6 3 7 Customizing the Calibration Area Customizing the calibration area can be useful if you have discovered that the user cannot access certain areas of the screen using eye control By sizing the calibration area to exclude the areas that the user cannot access it can improve the overall calibration To customize the calibration area follow the steps below l Open Tobii Eye Control Options gt Eye Tracking 2 Click the Calibration Area button 3 A blue semi transparent area is displayed on the desktop You can move and resize the blue area to make it fit your preferred calibration area 60 Chapter 6 Tobii CEye Module amp Eye Control Tobii C Series User s Manual 6 4 Windows Control Windows Control allows you to access the desktop and all applications of your
48. ible for the user to control a standard Windows desktop operating system with a two step selection method which reduces the risks of unwanted clicks It also prevents the following of the mouse cursor with your gaze as opposed to the controlling of it there is no floating mouse cursor in Gaze Selection The first step is to select the desired Task from the docked Task Bar by looking at it 2 second step is to look at the desired portion of the screen or icon on the screen where you want to execute the Task An automatic zoom function is enabled ending in the selection of the icon or execution of the task The settings for Gaze Selection are found the Gaze Selection Taskbar docked to the screen when Gaze Selection Windows Control is running Gaze at the cogwheel settings icon to select it and the Settings Dialog will open 6 4 3 1 Gaze Selection Taskbar At the top of the Gaze Selection Taskbar there is a Track Status viewer It allows you to verify that the eye tracker recognizes your eyes and that you are well positioned in front of the device The Task Buttons in the Gaze Selection Taskbar can be in three different modes as shown in the figure below e Normal Unselected No Task Button for Gaze Selection is chosen Selected marked Task Button is selected and the Task will be executed after the automatic zoom when the user looks at the 62 Chapter 6 Tobii CEye Module amp Eye Control Tobii C
49. icon in the Notification area 5 9 Using the WLAN optional Not applicable for RF Free units The built in WLAN Wireless Local Area Network support enables connection to a wireless network in compliance with the standard 802 11 b g for the C8 and 2 and 802 11 b g n for the CI5 5 9 1 Handling Licenses To be able to use WLAN communication a license is required To view or enter a license go to the Licenses section in the C Series Hardware Options 5 9 2 Enabling and Disabling the WLAN Communication You can enable and disable WLAN communication in the Wireless section in the C Series Hardware Options Chapter 5 Using the Tobii C Series 33 Tobii C Series User s Manual 7 Enable wireless units WLAN Environmental Control Switches pe Temperature Control M Touch Screen To enable WLAN communication l Selectthe Enable wireless units check box 2 Select the WLAN check box To disable WLAN communication e Clear the WLAN check box or clear the Enable wireless units check box for disabling all wireless units 5 9 3 Connecting to a WLAN To enable WLAN communication l Click on the WLAN icon the Notification area the Desktop 2 Select Connect to a network 3 Selecta network to connect to 9 A wireless access point which supports antenna diversity is recommended when setting up a wireless network to use with a C Series device for reliable performance
50. ies device has two battery compartments The batteries for the Tobii C8 differ in size and capacity from those of the Tobii CI2 and CI5 see the Appendix C Technical Specifications Tobii C8 batteries e Standard included Tobii CI2 and CIS batteries Standard included 4 1 1 Hot Swappable You can remove replace one battery without switching off the device providing that the remaining battery is sufficiently charged The remaining battery requires being at least 5 charged to maintain device operation 4 2 Charging The batteries should only be charged using the included adapter or by using the Tobii C Series Table Charger not included separate purchase required When the C Series device is shut down and the adapter is plugged in the charging of completely discharged batteries may take up to 6 hours The device can be used while the batteries are being charged though this may affect the time a battery takes to reach full capacity 4 To be sure that charging takes place in both the C Series device and when using the C Series Table Charger be sure to plug the adaptor into both the wall socket and the device or Charger BEFORE you insert the batteries The expected battery lifetime is 500 charge discharge cycles After that the capacity of the battery will decrease by about 2076 in usage time See Safety chapter for battery storage and charging temperatures Chapter 4 Batteries in the Tobii C Series Tobii
51. ii Eye Control Options in this chapter of the User s Manual for more information Chapter 6 Tobii CEye Module amp Eye Control 47 Tobii C Series User s Manual 48 6 2 Using the Tobii Module 6 2 1 Positioning The Tobii C12 or CI5 with the CEye attached is designed to work optimally when it is parallel to the user s eyes at a distance of about 60 cm 23 5 in This means that for those users leaning sideways or those lying down the CI2 CEye or CI5 CEye also needs to be tilted in order to keep the users eyes parallel to the screen and at the optimal distance Make sure the user is placed comfortably in relation to the optimal positioning of and distance from the unit Be aware also that the user s comfort as well as the Eye Tracking performance will be enhanced if the sun is not shining directly on the screen or into the user s eyes 6 2 2 Track Status Viewer Use the Track Status viewer see Using the Tobii C Eye Module Showing Track Status for more information on how open the Track Status viewer to help determine the optimal height and horizontal positioning for eye tracking with the CI2 CEye or CI5 CEye Ideally the two dots that represent the user s eyes should be in the middle of the Track Status viewer e Use the distance meter on the right hand side of the Track Status viewer to determine the optimal distance the user should be from the CI2 CEye or The white bar the dis
52. ize and to the left to decrease it Customize the zoom factor by moving the Zoom Factor slider Move the slider to the right to increase the zoom factor and to the left to decrease it Auto switch from right to left click Check this check box if you want Windows Control Mouse Emulation mode to automatically switch the desired mouse click selection back to a left click 6 after a right click has been chosen and performed Chapter 6 Tobii CEye Module amp Eye Control 69 Tobii C Series User s Manual Turn off scroll functionality e Checkthe Turn off scroll functionality check box if you do not want eye controlled scrolling to be active Custom cursors Custom cursors is a feature that turns the regular mouse cursor into a number of different cursors when using Windows Control in Mouse Emulation mode The different cursors visually represent the type of mouse click for eye control that you have chosen from the Mouse Emulation Menu for the definitions of the Nouse Emulation Menu symbols see Clicking with Windows Control in Mouse Emulation Mode Magnifying with Windows Control in Mouse Emulation Mode and Selecting Mouse Emulation Functions or cursor type MA move cursor no clicking cursor type EH single left click cursor type NH single right click cursor type double left click 6 cursor type E double right click or cursor types
53. n of the task Chapter 6 Tobii CEye Module amp Eye Control 65 Tobii C Series User s Manual e Switch Two different execution modes Single activation of the Switch the zoom function will execute in the same way as with the Gaze method and according to the settings made in the Gaze Selection Settings Dialog e Activate and hold the Switch the zoom function will zoom continuously and end only upon the release deactivation of the switch When using the Gaze method you always have to look back to the Taskbar to select a new Task after the execution of the Task even if it is the same as you have just used When using the Switch method the Task buttons will become sticky once you select them This means that you do not have to look back at the Taskbar if you want to repeat the execution of a selected Task only if you want to change the Task 6 4 3 4 Gaze Selection Settings The Gaze Selection Settings Dialog is Eye Controlled and the user can make all changes without using a keyboard and or a mouse GAZE SELECTION Settings Selection e Choose Gaze to use your gaze position to activate the zooming function that ends with the execution of the desired Task 66 Chapter 6 Tobii CEye Module amp Eye Control Tobii C Series User s Manual e Switch Choose Switch to use a switch to activate the zooming function that ends with the execution of the desired Task Precision The zoom p
54. n the Device 5 3 Configuring a Switch to Power On or Off 5 3 1 Configuring a Switch to Power On 5 3 2 Configuring a Switch to Power Off 5 4 Safety Settings C Series Hardware Options NNN 0 mur oo mE b i cA xh gh C ao sch sch OO RER P ch gt O1 4 0 o o 5 4 1 Audio Safety 5 4 2 Temperature Control Safety 5 4 3 Saving Changes for Future Sessions 5 4 4 Disabling Safety Page as Default Page on Startup 5 5 Adapting the Touch Screen for the User 5 5 1 Calibrating the Touch Screen 5 6 Adjusting the Backlight 5 6 1 Adjusting the Sound 5 7 Using Headphones 5 8 Using Bluetooth optional 5 8 1 Handling Licenses 5 8 2 Enabling and Disabling Bluetooth Communication 5 8 3 Connecting to a Bluetooth Device 5 9 Using the WLAN optional 5 9 1 Handling Licenses 5 9 2 Enabling and Disabling the WLAN Communication 5 9 3 Connecting to WLAN 5 10 Using the Camera 5 11 Using the Mobile Phone optional 5 11 1 Handling Licenses 5 11 2 Enabling and Disabling the Mobile Phone 5 12 Using Environmental Control optional 5 12 1 Handling Licenses 5 12 2 Enabling and Disabling Tira 5 13 Creating Shortcuts to Actions 5 13 1 Available Actions 5 13 2 Selecting Actions 5 14 Handling Licenses 5 15 System Information 5 16 Performing Backup and Restore 5 16 1 User Profile Card 5 16 2 Restoring Backup Files by the User 5 16
55. n the sides of the display turn orange and the device shuts down It may take a while before it can be restarted as the unit may first need time to cool down Return to C Series Hardware Options gt Safety to save changes for future sessions Chapter 5 Using the Tobii C Series Tobii C Series User s Manual 5 4 3 Saving Changes for Future Sessions To save your changes for future sessions l Select the Save my changes for future sessions check box 2 Click Apply or OK to save Both the audio and the temperature control settings will be stored in memory If this check box is not selected when you click Apply or OK the settings will only be stored until you log out 5 4 4 Disabling Safety Page as Default Page on Startup The Safety page is shown by default when the C Series device is started In order to disable Open the C Series Hardware Options gt Safety 2 Select the Do not show this page on startup check box 3 Click Apply or OK to save Chapter 5 Using the Tobii C Series 27 Tobii C Series User s Manual 28 5 5 Adapting the Touch Screen for the User The Touch Screen interprets your touch and moves the cursor to wherever your finger contacts the screen The Touch Screen can be calibrated for your touch either by the separate touch screen software TouchKit Windows Vista eGalaxTouch Windows 7 or in the C Series Hardware Options Use your finger or a stylus on the Touch Screen Do no
56. ndix A Training Resources 8 2 Appendix B CEye Software License 8 3 Appendix C Compliance Information 8 3 1 FCC Statment 8 3 2 Radio Wave Exposure and Specific Absorption Rate SAR Information 8 3 3 Industry Canada Statement 8 4 Appendix D Technical Specifications 8 5 Appendix E Approved Accessories 50 51 51 52 52 54 55 55 55 55 56 57 58 60 61 61 61 62 68 74 74 74 74 74 75 76 76 77 77 77 78 78 78 78 78 79 84 86 88 Tobii C Series User s Manual Introduction Thank you for purchasing a Tobii C Series device from Tobii Technology To ensure the optimal performance of this product please take the time to read this manual carefully The C Series device is available in three different sizes the Tobii C8 with 8 4 screen the Tobii C12 with 12 1 screen and the Tobii CI5 with a 15 0 screen The Tobii CI2 and CIS can be used with the Tobii CEye to enable eye control of the device This User s Manual covers C Series device models Tobii C8 Tobii CI2 and Tobii C15 e The C Series Hardware Options program for controlling the device and licenses Tobii CEye eye tracking module including Windows Control Tobii CEye is optional equipment and is only used with the Tobii CI2 and EIS 1 1 Intended Use A variety of communication methods allow Tobii C Series users the ability to achieve their full potential A user can communicate via text or symbols to
57. ns for clicking h Mouse cursor Rs No cursor movement on screen e Single click Double click Drag and drop 6 4 4 6 Pausing Windows Control in Mouse Emulation Mode To pause Windows Control select the Pause icon in the Windows Control Menu il Pause When Windows Control is not enabled pausing eye control can also be accomplished by looking at about the Tobii logo at the bottom center of the Tobii CEye then selecting using eye control the pause icon that pops up 72 Chapter 6 Tobii CEye Module amp Eye Control Tobii C Series User s Manual 6 4 4 7 Scrolling with Windows Control in Mouse Emulation Mode The scroll buttons appear automatically in the upper right corner in any object which can be scrolled The buttons will only appear on the window which has focus To activate the scroll press the icon If the buttons are in the way you can use the icon to hide them When scroll mode is activated you will see a shaded gradient over the window which will be scrolled ECKE Parental Penand People Near Performance Personali Ph Power Controls Input Devices M Options Programs Realtek HD Regional and Scanners and Security andFestures Audio Language Cameras Center w g LL Tablet PC Taskbarand Tetto Settings Start Menu Speech B ou x Windows Windows Windows CardSpace Defender Firewall To scroll look at the top or bot
58. nvironment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the C Series device is used exceeds the applicable RF compliance level above the C Series device should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as reorienting or relocating the C Series device Over the frequency range 150 kHz to 80 MHz field strengths should be less than 3 V m Recommended separation distances between portable and mobile RF Radio Frequency communications equipment and the C Series device The C Series device is intended for use in the electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the C Series device can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communication equipment transmitters and the C Series device as recommended below according to the maximum output power of the communications equipment Rated maximum Separation distance according to frequency of transmitter output power of transmitter 150 kHz to 80 MHz 80 MHz to 800 800 MHz to 2 5 W MHz GHz Under test specifications specified in 6 2 1 10 60 601 1 2 2007 the C Series device shall not Exhibit component failure Exhibit changes in its programmable parameters e Resetunintentionally to facto
59. o configure the sound in C Series Hardware Options Open the C Series Hardware Options gt Audio 2 Click one of the options below Speaker output Audio Choose your preferred audio settings The speakers can be configured to output either one of the left or right channels both channels Stereo or neither Mute Backlight Environmental Control Speaker output Mute Stereo Switches ture Control EES D Left channel in both speakers Touch Screen Right channel in both speakers Wireless Enable headphones Safety Licenses System Information The two audio channels Left and Right provide two levels of audio output For example the Left Channel may output the auditory scanning cues to the user s headphones while the Right Channel could output the chosen text to the speakers of the device to be spoken aloud Please note that the Left and Right Channel do not refer to left and right speakers Either channel can output sound audio to both of the speakers Chapter 5 Using the Tobii C Series 31 Tobii C Series User s Manual 5 7 Using Headphones If you want to enable the use of headphones Open the C Series Hardware Options gt Audio 2 Select the Enable headphones check box If you want to disable the use of headphones l Open the C Series Hardware Options gt Audio 2 Click to clear the Enable headphones check box Wirel fireless M Enable headphones Safety
60. on your choice of a Tobii C Series Device To make the most of your experience with your C Series device please follow this 5 step quick guide it should only take about two minutes of your time Note The guide will only take about two minutes to complete but if you wish you can opt out of going through the steps by clicking on Ask me later If you opt out the Welcome Guide will open again the next time you start your device Chapter 5 Using the Tobii C Series 19 Tobii C Series User s Manual 5 1 3 C Series Welcome Center The C Series Welcome Center is the program on your C Series Device where you can access and change the settings that you have chosen during your first setup with the C Series Welcome Guide or even run the Welcome Guide again at a time of your choosing To open the C Series Welcome Center Navigate in Windows from your desktop to Start Menu gt All Programs gt Tobii gt C Series Welcome Center and click on the C Series Welcome Center icon or Navigate in Windows from your desktop to Start Menu Control Panel Additional Options and click on the C Series Welcome Center icon or if you use the Classic View for your Control Panel Windows Navigate in Windows from your desktop to Start Menu gt Control Panel and click on the C Series Welcome Center icon Within the C Series Welcome Center you can e Run the C Series Guide immediately or choose to have it run upon the next
61. ovided or that are integrated in the device may affect EMC performance The SAR Specific Absorbtion Rate limit as dictated by the FCC in the USA is 1 6W kg averaged over gram of tissue In Europe EU regulations it is 2 0 W kg averaged over 10 grams of tissue The Devices Tobii C8 ID WSMTOBIIC8 Tobii CI2 FCC ID WSMTOBIICI2B and Tobii 5 FCC ID WS5MTOBIICIS5 have been tested against these SAR limits to maintain compliance with FCC CE RF exposure requirements This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment The highest SAR value for the C8 device is 1 025 W kg The highest SAR value for the CI2 device is 0 107 W kg The highest SAR value for the 5 device is 0 16 W kg Chapter 8 Appendices 79 Tobii C Series User s Manual Guidance and manufacturer s declaration electromagnetic emissions The C Series is intended for use in the electromagnetic environment specified below The customer or the user of the C Series device should assure that it is used in such an environment Emissions Test Compliance Electromagnetic environment guidance RF Radio Frequency The C Series must emit emissions CISPR 11 electromagnetic energy in order to perform its intended function Nearby electronic equipment may be affected RE emissions CISPR Il a 556 Harmonic emissions Not Applicable The product has an active power of IEC 61000 3 2 lt 7
62. r adapter and batteries 3 Place the Tobii CI2 CI5 face down on a flat surface 4 Use the accompanying Torx 10 screwdriver and screws to mount the CEye to the Tobii CI2 CI5 Do not overtighten the screws tighten until you encounter resistance Overtightening may increase risk for breakage and will not improve functionality First screw one screw in lightly then the second lightly Second tighten the first screw then the second Chapter 6 Tobii CEye Module amp Eye Control DA Tobii C Series User s Manual 6 1 2 Required Software The required software for the CEye module is the Tobii Eye Control Suite The Tobii Eye Control Suite includes two components the interaction server application and a system tray application Tobii Eye Control Options The interaction server runs in the background and has no user interface A user interface is instead provided by the tray application Tobii Eye Control Options or by Tobii Communicator or alternative communication software The interaction server also contains the Windows Control application accessible from the Tobii Eye Control Options The latest required software will be on a USB stick delivered with the CEye Module 46 Chapter 6 Tobii CEye Module amp Eye Control Tobii C Series User s Manual 6 1 3 Installation of Eye Control Software from USB Stick To install the latest necessary software from the USB stick make sure the C Series Device is turn
63. r of the power supply since you may be exposed to potentially hazardous electrical voltage The device contains no serviceable parts If the C Series device or it s accessories are mechanically damaged do not try to use them 2 1 Avoiding Hearing Damage Permanent hearing loss may occur if earphones headphones or speakers are used at high volume To prevent this the volume should be set to a safe Chapter 2 Safety Tobii C Series User s Manual level You can become desensitized over time to high sound levels which may then sound acceptable yet still could be damaging your hearing If you experience symptoms such as ringing in your ears please lower the volume or stop using the earphones headphones The louder the volume the less time is required before your hearing could be affected Hearing experts suggest the following measures to protect your hearing Limit the amount of time you use earphones or headphones at high volume e A Avoid turning up the volume to block out noisy surroundings e Turn the volume down if you cannot hear people speaking near you To establish a safe volume level I Set your volume control at a low setting 2 Slowly increase the sound until you can hear it comfortably and clearly without distortion 2 2 Mounting Warning The C Series devices should be mounted according to instructions for approved mounts or mounting brackets However should the device for any reason harm or damage someone
64. re mounted on the device Astylus e System restore discs e Communication software installation disc if ordered The Tobii CEye package if included with the Tobii C12 or CIS ATobii CEye module with two screws attached ATorx 10 screwdriver A Getting Started Guide AUSB stick with the latest necessary software 1 3 Customer Support For support please contact your local representative or Support at Tobii In order to receive assistance as quickly as possible make sure you have access to your C Series device and if possible an Internet connection You should also be able to supply the serial number of the device which you find on the back of the device or in the C Series Hardware Options see the System Information section in the Using the Tobii C Series chapter For further product information and other support resources please visit the Tobii community www mytobiicommunity com and the Tobii website www tobii com 1 4 Warranty Please read this User s Manual carefully before using the device The warranty is only valid if the device is used according to the User s Manual and the warranty seal is not broken Disassembling the C Series device will void the warranty Chapter 1 Introduction 7 Tobii C Series User s Manual Safety The C Series device has been tested and approved as compliant to all the Specifications and Standards listed in the 8 3 Appendix Compliance Information section
65. recision can be set to 8 different levels just look at the desired position to change the setting Changing the Precision will adjust how deep the zoom will go before executing the Task The further to the right on the scale the deeper the zoom Speed The zoom speed can be set to 8 different levels just look at the desired position to change the setting Changing the Speed will affect how fast the zoom is before the execution of the Task The further to the right on the scale the faster the zoom To finish select OK to save or Cancel to abort you changes 6 4 3 5 Gaze Selection in Combination with Region Based Keyboards Gaze Selection can be used in combination with other eye controlled applications Eye Enabled regions in other applications are active as long as there is no active Task in the Gaze Selection Toolbar If you are using Gaze Selection with switch the Task Buttons will be sticky if you need to deselect a Task just look back at the selected Task for a short moment Chapter 6 Tobii CEye Module amp Eye Control 67 Tobii C Series User s Manual 6 4 3 6 Gaze Selection with Windows Full Screen Mode When using Gaze Selection to view images films and files or to run programs in Windows Full Screen mode the Gaze Selection Taskbar will be covered To be able to exit Windows Full Screen mode without the Taskbar an Esc command has been emulated with Gaze selectable in the top left
66. ry defaults e Emitfalse alarms Initiate any unintended operation even if accompanied by alarm Chapter 8 Appendices 83 Tobii C Series User s Manual With regard to the test specifications specified in 6 2 1 10 EN 60 601 1 2 2007 the cessation or interruption of any intended operation even if accompanied by an alarm is allowed in the C Series device due to it not performing any safety critical operations Also with regard to the test specifications specified 6 2 1 10 EN 60 601 1 2 2007 errors of a displayed numerical value sufficiently large to affect diagnosis or treatment is not applicable for the C Series device In order to maintain compliance as a Class Medical device the switches that are used in combination with the C Series device must fulfill the isolation requirements of IEC EN 60601 1 based on 15 V DC They must be electrically floating switches switches that are not grounded 8 3 3 Industry Canada Statement This device complies with Industry Canada licence exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire
67. se volume Mute volume on off Backlight choose to either increase or decrease the screen backlight by clicking the preferred option Backlight Increase screen backlight Decrease screen backlight Eye Tracking choose to toggle track status window calibrate eye tracking or toggle eye tracking on off Chapter 5 Using the Tobii C Series Tobii C Series User s Manual Eye Tracking Toggle track status window Calibrate eye tracking Pause eye tracking on off To enable this option you have to install the Tobii Eye Control Suite and a CEye See Tobii CEye Module chapter Wireless you can either set all radio connections on off or each individual wireless unit on off one by one by clicking the options 9 Wireless Wireless units on off WLAN on off Bluetooth on off Mobile phone on off Touch Screen choose to turn the touch screen on or off Wireless Touch Screen Touch screen on off If actions for a Switch are customized both in the C Series Hardware Options and in Tobii Communicator or in alternative communication software all actions will be performed simultaneously Ensure that the specified action for a Switch does not conflict with an action set for the same Switch in Tobii Communicator or in alternative communication software Chapter 5 Using the Tobii C Series 41 Tobii C Series User s Manual 5 14 Handling Licenses To add new and or view existin
68. ser Profiles 2 Enter a new name in the Profile name field 3 Select an existing profile in the Based on profile drop down list The new profile will inherit all settings from the selected profile Note that if no profiles have been created previously the only one to select is the default profile 4 Click Create to save the new profile The new profile is saved directly upon clicking Create Interaction Create a new profile A Windows Control Settings gased on profile 2 NE System Settings 6 2 6 Selecting Current User Profile To select current user profile l Open Tobii Eye Control Options 2 Selecta user profile in the Current User Profile drop down list 3 Select Apply Eye Tracking User Profiles Functionality to administrate user profiles Current User Profile Calibration Settings Chapter 6 Tobii CEye Module amp Eye Control 51 Tobii C Series User s Manual 6 2 7 Deleting a Profile To delete a profile l Open Tobii Eye Control Options gt User Profiles 2 Selecta profile in the Profile to delete drop down list 3 Click Delete to delete the selected profile The profile is deleted directly upon clicking Delete Note that the default profile cannot be deleted System Information Delete a profile Profile to delete Guest 7 Delete 6 2 8 Customizing the Interaction ll Control Options Connected Current User Profile Eye Tracking Interaction
69. start up The C Series Welcome Guide is a setup wizard for all settings in the C Series cse i C Series Update Notifier Welcome Cener VIP User Registration Run Welcome Guide at next Windows startup Run Welcome Guide now Run Welcome Guide e Choose to enable the automatic updates for your Tobii software or search for updates immediately must be connected to the internet 20 Chapter 5 Using the Tobii C Series Tobii C Series User s Manual Welcome Gude C Series Update Notifier C Series Update Notifier The C Series Update Notifier enables automatic software updates of Tobii software We strongly recommend that you enable automatic updates VIP User Registration V Enable automatic updates Check for updates now Check for updates e Register as a VIP User Welcome Guide VIP User Registration C Series Update Notifier VIP users receive the latest news from Tobii including special offers and more Changes to your VIP User settings require an Internet connection to become First name Last name Email address 7 I want to receive email notifications from Tobii no one other than Tobii will be allowed to use your submitted information 5 1 4 C Series Update Notifier The Tobii C Series Update Notifier is a program that notifies you when the latest software updates for your Tobii Software are available either automatically on a r
70. t use any sharp objects as the screen could scratch or break 5 5 1 Calibrating the Touch Screen Using the Touch Screen calibration in the C Series Hardware Options Open the C Series Hardware Options gt Touch Screen 2 Press the calibrate button to start a calibration of the Touch Screen The screen will turn white and display an active red target in the bottom left corner with a progress bar beside it 3 Touch and hold the target before the 15 seconds is up it will turn yellow Continue holding until the timer clock has counted up to 10076 The target will then move to the next corner anticlockwise counterclockwise Audio Backlight Buttons Environmental Control Switches Temperature Control Wireless Safety Licenses System Information Touch Screen Calibrate the touch screen display Click Calibrate to start a new calibration Calibrate Chapter 5 Using the Tobii C Series Tobii C Series User s Manual Using the Touch Screen software calibration l For Windows Vista Go to Start menu gt All Programs gt TouchKit gt Configure Utility For Windows 7 Go to Start menu gt All Programs gt eGalaxTouch gt Configure Utility 2 Select the Tools tab 3 Click on 4 Points Calibration to start the calibration of the touch screen The screen will turn white and display an active red target in the bottom left corner with a progress bar beside it 4 Touch and hold the target before the
71. tance meter should hover near the center within the green when the optimal distance from the 2 or CI5 CEye is reached Chapter 6 Tobii CEye Module amp Eye Control Tobii C Series User s Manual For information about calibration of the CEye see Using the Tobii C Eye Module gt Calibrating Also check the lighting conditions related to what is mentioned above when calibrating 6 2 3 Track Box The Tobii CEye allows for extensive head movement Once the CI2 CEye or CI5 CEye is properly calibrated and placed in front of the user no further adjustments are required The Tobii CEye produces an industry leading sized track box with the approximate dimensions of 40 cm x 30 cm 20 cm 15 7 in x 11 8 in x 79 in Width x Height x Depth The Track Box is an invisible box positioned approximately 60 cm 23 5 in straight out from a point just above the middle of the CI2 screen In order to be tracked properly for functional Eye Tracking the user needs at least one eye in the track box at all times Tobii CEye Module amp Eye Control Tobii C Series User s Manual 6 2 4 Accessing the Tobii Eye Control Options The Tobii Eye Control Options is a program for quick and easy access to control functions such as track status calibration and common settings You start Tobii Eye Control Options in one of the following ways Go to Start menu gt All Programs gt Tobii gt Tobii Eye Control S
72. tings C Series Hardware Options Upon starting the device the safety settings in C Series Hardware Options will open as the default page automatically other that during the first start up of the device when the C Series Welcome Guide setup wizard will open first The safety settings exist for the safety of the customer Be sure to read the safety details before accepting any changes SES Audio Safety Backlight Control the unit s safety settings Read the safety details before enabling additional functionality Changes are accepted when Apply Buttons or OK is clicked Environmental Control Switches Audio safety details Tarere Comes the speaker funciionalty 7 I have read and understand the safety details and I want to enable A Touch Screen Temperature Control Temperature control safety details E 1 have read and understand the safety details and I want to enable A the temperature control functionality Wireless Licenses E Sa safety ch for fut System Information exce metet centes Tur nues sessione 7 Do not show this page on startup Ca Cea 5 4 1 Audio Safety Before you can use the speaker functionality and adjust speaker output settings in C Series Hardware Options gt Audio you need to confirm the Audio safety details To confirm Open the C Series Hardware Options gt Safety 2 Click on the Audio safety details text A new dialog box opens and displays the s
73. tion Point s If there is a calibration point that is consistently bad after calibration the green lines are scattered all around and outside the circle of the calibration point you can remove that point completely from the calibration this may improve the calibration of the other points Be aware that if you remove a point that area of the screen will be uncalibrated and eye tracking will not function properly there Remove one or more calibration points by Opening Tobii Eye Control Options gt Eye Tracking 2 Under Calibration Result marking the point s you want to remove 3 Clicking Remove Point s Chapter 6 Tobii CEye Module amp Eye Control 57 Tobii C Series User s Manual 6 3 6 Customizing the Calibration Control Options Connected Current User Profile Eye Tracking Calibration Settings 222 etre eer ete Inte User Profiles Windows Control settings casei points System Settings eines System Information stimulus Simdewpe DE Animate simui ints Paray struts Secondary cime Stimulus Sze Medium gt Stimulus speed Medium El Keyboard step through Fosttioning guide IE Show the positioning guide prior to calibration Use S key to step and Ee key or Left mos Image orvigeo excretion use T key to toggle To customize the calibration follow the steps below Open Tobii Eye Control Options gt Calibration Settings Gener
74. tom of this gradient area Scroll functionality can be turned off in Tobii Eye Control Options gt Windows Control Settings gt Turn off scroll functionality Chapter 7 Product Care 73 Tobii C Series User s Manual 7 Product Care 7 1 Temperature amp Humidity 7 1 1 General Use The Tobii C series and CEye is best kept in dry conditions at room temperature The recommended range for temperature and the humidity value for the device is as follows Portable mode Temperature 0 C to 30 C 32 F to 86 F Humidity Max 70 no condensation on the device Mounted mode Temperature 0 C to 40 C 32 F to 104 F Humidity Max 70 no condensation on the device 7 1 2 Transportation and Storage For transportation and storage excluding batteries the recommended range for temperature and the humidity value for the device is as follows Temperature 40 C to 70 C 40 F to 158 F Humidity 20 to 70 no condensation on the device The Tobii C series and CEye is not waterproof or water resistant The device should not be kept in excessively humid damp or otherwise wet conditions Do not submerge the device in water or in any other liquid Be careful not to allow liquids to be spilled upon the device 7 2 Changing the Side Covers To remove the side covers l Shut down the C series 2 Remove the power adaptor and batteries See Installing and Releasing the Batteries 3 Place the C Series device fa
75. uite gt Tobii Eye Control Options Double click on the Tobii Eye Control Options icon in the Notification area or on the shortcut on the Desktop if one has been made Right click hold finger on icon for touch screen right clicking on the Tobii Eye Control Options icon H in the Notification area and then click Settings In the list to the left in Tobii Eye Control Options select which option you want to change In the list to the right the available options will be revealed Click OK to save changes This will also close Tobii Eye Control Options closes Click Cancel to cancel the changes This will also close Tobii Eye Control Options Click Apply to save changes Tobii Eye Control Options will remain open Eye Tracking Functionality to configure eye tracking for the selected profi Calibrate Perform a calibration based on the curent calibration settings C Teks Senses Cairo Area Calibration Result Chapter 6 Tobii CEye Module amp Eye Control Tobii C Series User s Manual 6 2 5 Creating a New Profile Use of different profiles allows you to store multiple people s calibrations and feedback preferences on one device Alternatively one person might want to store multiple profiles for him herself if that person wears glasses occasionally or uses multiple means of accessing the device To create a new profile l Open Tobii Eye Control Options click U
76. vice pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur ina particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Chapter 8 Appendices Tobii C Series User s Manual Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into a wall outlet on a circuit different from that to which the receiver is connected Consult the dealer or experienced radio TV technician for assistance 8 3 2 Radio Wave Exposure and Specific Absorption Rate SAR Information The C Series device has been tested as a Class Medical Device Medical electrical equipment such as this requires special caution regarding Electro magnetic Compatibility EMC and thus needs to be installed and placed into service according to the information provided in this manual A Using other cables and accessories other than those pr
77. ye Make sure you ve connected the power supply before you start the process do not run the device on batteries as it might run out of power during the factory restore In such a scenario you might have to send the unit back to Tobii for repair 44 Chapter 5 Using the Tobii C Series Tobii C Series User s Manual Tobii CEye Module amp Eye Control The Tobii CEye Module is an eye control unit which is designed to dock seamlessly into a Tobii C12 or CIS not used with C8 and operate with precision regardless of glasses contact lenses eye color or light conditions The CEye Module enables you to control the computer with your eyes By looking at the screen you control the mouse pointer and you click by blinking dwelling staring at the screen for a certain length of time or using a Switch 6 1 Installing the Tobii CEye Module To enable eye control with a Tobii C12 or CIS you must first connect the Tobii CEye Module to the device and then install the Tobii Eye Control Suite See instructions below A Do not use the table stand or regular mounting bracket stand with a CEye connected 6 1 1 Mounting the CEye Module to the Tobii C12 or C15 when mounting the Tobii CEye to a Tobii CI2 or 5 it is important that the contact areas between them are clean Mount the CEye to the Tobii CI2 or CIS in the following way l Make sure that the Tobii CI2 CI5 is shut down 2 Remove the powe