Home

SERIALDIS Manual - Applied Measurements Ltd

image

Contents

1. SERIALDIS Serial ASCII Display Module ors any User Manual WWW mantracourt co uk THE QUEEN S AWARDS FOR ENTERPRISE 2001 M mantracourt Contents SERIALDIS OVer vie Wectustioiiani totali OVERVIOW icsse sororia reiron e aao rre rR aso sar droit aop RESE Io erT EE deco nas tado Requirements i acesas ass siena in EEE EEEE DA neta voles ee sabe SEMDE ESE EAA E ATEEN STS a E Configuration suas canino a atira ne e Aa EREET EREE K e DEAE ESE REE E E EPEAN lows casada Operation see orein CAT Fones IIIN Do Ina eed ds dee STOINA oe Le TIRa EI o T ARARE Teh Physical Connections sissano anne On Single PC CONNECtiON aus tomas pio ado chad ee ce ils iO de de Up cite ob Sew ATA dO Ae qua bre alo ole ta pete Multidrop R 232 ccoo id At id 6 UU a MUltidrop RS48 5 5 scsi A A A a Configuration cat a A a a ia ias da Error REPOLtINA xas nitro nooo aan ano ind ea ESTEA Control Codes ii A a ciao SA RO Display Example iii ss Character Representations oii ass sans aneis iusscs sas op ni coa Sana tania Specification ssa DATA id ESE DSE Environmental o icons ote CE ApprovalS s assessor anotando see seed cease vases Gula den de seeded caveats da esa ai pa dad UE A senso coengan da sedes oia Tor AE A sds des A e aaa en inda Ieda sadias RN 1 Mantracourt Electronics Limited SerialDis User Manual SERIALDIS Overview The SERIALDIS is a 6 digit LED display module which displays ASCII data sent to it via an RS232 or RS485 serial connection
2. The device has addressing support so multiple devices can be driven whilst residing on a serial bus Being a 7 segment display it is not possible to display all alphanumeric characters so this display is primarily for numeric data Overview Requirements The module requires a serial input either RS232 or RS485 which supplies the data to display followed by a carriage return The baudrate is selectable from 9600 to 115200 but is fixed at 8 data bits 1 stop bit and no parity Configuration Configuration is by DIP switches where the baudrate and address can be set Operation The display accepts ASCII data and on receipt of a carriage return character decimal 13 hexadecimal OD the data will be displayed Physical Connections Single PC Connection Connect power to The Power In connector q sui ON IM OFF Connect to the serial bus using either J1 or J4 for RS232 or J2 for RS485 J3 9 Way D Socket RS232 Pinouts CTS Tx Rx GND GND B GND GNDGND RS232 RS485 POWER OUT POWER IN Y v A o o o I o 9 Ji J2 3 RX In View f insid iew from inside case 5 GND J4 has been designed to enable a quick connection to a PC for testing by using a 9 way D cable extension pin to pin and connecting to the PC 9 way D socket Mantracourt Electronics Limited SerialDis User Manual Multidrop RS232 on M orr SW1 set for baudrate of 19200 and an address of 1 lef
3. If a module is addressed as zero via SW1 then it will display all data Display Examples Each piece of data sent to the display must end in a carriage return decimal 13 hexadecimal 0x0D For clarity the carriage returns are not shown in the following table The following examples show the resulting display for data received 123 4 123 4 123 456 1 23 455 00123 4 001 23 4 Hello HELLO WARNING if more data is sent than will fit in the 6 digit display the right most portion will be shown Take care when sending numeric data that it is not too long otherwise integer digits will be lost 123 4567 234564 1234 56789 455783 5 Mantracourt Electronics Limited SerialDis User Manual q nH O N e PU a Q E v a MEL JO CL a D do 00 10 E OL di EE Ea Y 00 00 00 00 LU CJ CN 1 0 L 10 gar 10 T LU J Specification Supply Voltage Nominal Voltage 8 to 18V dc Current Consumption Max 200mA Communications RS232 and R 485 8 data bits 1 stop bit no parity Environmental Storage temperature 20 to 70 C Operating temperature 10 to 50 C Relative humidity 95 maximum non condensing CE Approvals European EMC Directive 2004 108 EC BS EN 61326 1 2006 BS EN 61326 2 3 2006 Warranty All Wireless Telemetry products from Mantracourt Electronics Ltd Mantracourt are warranted
4. In the interests of continued product development Mantracourt Electronics Limited reserves the right to alter product specifications without prior notice Code No 517 913 Issue 1 1 19 11 09 7 Mantracourt Electronics Limited SerialDis User Manual
5. against defective material and workmanship for a period of 1 one year from the date of dispatch If the Mantracourt product you purchase appears to have a defect in material or workmanship or fails during normal use within the period please contact your Distributor who will assist you in resolving the problem If it is necessary to return the product to Mantracourt please include a note stating name company address phone number and a detailed description of the problem Also please indicate if it is a warranty repair The sender is responsible for shipping charges freight insurance and proper packaging to prevent breakage in transit Mantracourt warranty does not apply to defects resulting from action of the buyer such as mishandling improper interfacing operation outside of design limits improper repair or unauthorised modification No other warranties are expressed or implied Mantracourt specifically disclaims any implied warranties of merchantability or fitness for a specific purpose The remedies outlined above are the buyer s only remedies Mantracourt will not be liable for direct indirect special incidental or consequential damages whether based on the contract tort or other legal theory Any corrective maintenance required after the warranty period should be performed by Mantracourt approved personnel only ISO 9001 REGISTERED FIRM THE QUEEN S AWARDS D q La A FOR ENTERPRISE as AMS C
6. r Reporting If no serial data arrives for within 10 seconds default the display will show NoData As soon as new data arrives this will be displayed instead Control Codes Embedding control codes in the ASCII data can control certain functions of the display Mantracourt Electronics Limited SerialDis User Manual Control Byte Value Byte Function 0x01 Address The value byte contains the address of the display device to send the data to 0x02 Timeout The value byte contains the new timeout period in seconds This can be between 0 and 30 The default is 10 0x03 LEDs The value byte contains value whose binary bit values indicate whether to turn on or off the row of 4 LEDs A value of 1 would light the rightmost LED A value of 8 would light the left most LED A value of 3 would light the two right hand LEDs 0x04 Flash The value byte indicates whether to flash the display A value of 1 will cause the display to flash and a value of zero will stop it flashing Addressing Up to 15 display modules can be uniquely addressed on an RS232 or RS485 bus To address a particular module send the special control character 0x01 followed by a byte indicating the address i e To send data to display module addressed as 7 the following would be sent 0x01 0x07 123 456 0x0D Where the square brackets indicate a single byte whose value is shown in hexadecimal If data is sent with no addressing control bytes then all displays will show the data
7. t and 2 right 000000 4 00000098 an H 518 886 Issue 1 RS232 Serial Device TX D gt GND GND V Multidrop RS485 ON i OFF i SW1 set for baudrate of 38400 and an address of 8 left and 9 right Switch position 1 must be on to terminate RS485 bus Last device on bus EO JOJO JOJO TO O NY 0 ROJO JOJOJOJOJO wn E 0000000 de o GND V 3 Mantracourt Electronics Limited SerialDis User Manual Configuration RS485 Terminating resistor baudrate and address can be selected by DIP switch SW1 The numbers at the top of each table refer to the individual switches in SW1 RS485 Terminator Resistor On an RS485 bus the first and last modules on the bus should be terminated with a 120R resistor 1 Off No Terminating Resistor On 120R Terminating Resistor Applied Baudrate dl the ia to match the data that will drive the display Off Off 9600 Off On 19200 On Off 38400 On On 115200 Address Set the address of the display To disable addressing set to all Off 5 6 7 8 Off Off Off Off 0 Off Off Off On 1 Off Off On Off 2 Off Off On On 3 Off On Off Off 4 Off On Off On 5 Off On On Off 6 Off On On On 7 On Off Off Off 8 On Off Off On 9 On Off On Off 10 On Off On On 11 On On Off Off 12 On On Off On 13 On On On Off 14 On On On On 15 NOTE DIP switch changes require a power cycle to implement Erro

Download Pdf Manuals

image

Related Search

Related Contents

Analog Stereo Audio Routers VikinX Sublime Series User manual  Hunter 43042-01 User's Manual  Tacens Radix Eco II 600W  Digitaler Farb-Quadrantenteiler  Dealer Manual - Amazon Web Services  Samsung NP-N208 คู่มือการใช้งาน (FreeDos)  CC242ESSB - Cardin Elettronica  もみがらタンタン入り水稲育苗培土  DM32 Virtual Gauge Manual  manual de la LBH-1790  