Home
SCT 3000 Smartline Configuration Toolkit Model SCT 101
Contents
1. RS 232 Converter Driver Software See the Installation Instructions sheet 34 ST 33 61 SCT 3000 Smartline Configuration Toolkit SCT 3000 Hardware Interface Parameters Parameter DE Modem Standard Hardware Interface RS 232 Interface Option ST Communication Protocol Compatible with Honeywell Smart Field Network SFN Computer interface RS232 Field Device interface Compatible with 5Vdc level or 3Vdc level Baud Rate Temperature Range Operating Storage 9600 bps typical 10 C to 50 C 20 C to 60 C 19200 bps maximum 9600 bps typical 0 C to 50 C 32 F to 122 F ambient 40 C to 85 C 40 F to 185 F ambient Operating Humidity Range RH 10 90 noncondensing 10 90 noncondensing Weight Hardware Interface cables 0 45lbs approx 0 5 Ibs maximum Approval Bodies EUROPE European EMC Standards EEC Directive 89 336 EMC CE Mark European EMC Standards CE Mark SCT 3000 Smartline Configuration Toolkit 5 Model Selection Guide Model Selection Guides are subject to change and are inserted into the specifications as guidance only Prior to specifying or ordering a model check for the latest revision Model Selection Guides which are published at www honeywellprocess com sct 3000 smartline configuration toolkit aspx SCT 3000 Smartline Configuration Toolkit Model Selection Guide Instructions e Select the de
2. contain software version 2 2 or earlier or version 6 1 or earlier Honeywell Figure 1 The SCT 3000 Engineering and Maintenance Software application operating on a laptop PC communicates with a variety of Honeywell Smart field devices and provides easy access to all Smartline configuration database parameters On line and Off line Modes You can setup field device databases in either on line or off line modes The off line mode allows you to configure and store device databases before receipt of the field devices In the on line mode you can download the stored databases to the devices and perform on line functions such as e Configuration and device diagnosis e Calibration e Display of device parameters e Device check out e Selection of the Communications Mode Built in Database Templates Default database templates are provided for each type of field device Templates simplify and greatly reduce configuration time effort and error by providing a logical starting point SCT 3000 Smartline Configuration Toolkit Features Database Verification Database parameters are checked for reasonable values automatically to help avoid mistakes The SCT 3000 compares and detects differences between the device database and the SCT database providing assurance of proper installation Flow Wizard The SCT 3000 includes a wizard that provides considerable time savings and ease of use for users wishing to config
3. 45583 Phone 1 800 423 9883 Phone 55 11 7266 1900 i FAX 44 0 1344 655554 Or 1 800 343 0228 FAX 55 11 7266 1905 omer EPET Email Sales sc cp apps Email Sales ask Email Sales ask Onley wen IMIE salespa62 honeywell com ssc honeywell com or ssc honeywell com or Phone 61 7 3846 1255 OF a TAC hfs tac support honeywell com support honeywell com Toll Free 1300 36 39 36 support honeywell com Toll Free Fax 1300 36 04 70 China PRC Shanghai Honeywell China Inc Phone 86 21 5257 4568 Fax 86 21 6237 2826 Singapore Honeywell Pte Ltd Phone 65 6580 3278 Fax 65 6445 3033 South Korea Honeywell Korea Co Ltd Phone 822 799 6114 Fax 822 792 9015 Specifications are subject to change without notice Smartline is a registered trademark of Honeywell Windows is a registered trademark of Microsoft Corporation For More Information Learn more about how Honeywell s Smartline Configuration Toolkit can increase productivity of your industry visit our website www honeywellprocess com or contact your Honeywell account manager Honeywell Process Solutions 1860 West Rose Garden Lane 34 CT 03 02 Phoenix Arizona 85027 July 2013 2013 Honeywell International Inc Tel 1 800 423 9883 or 1 800 343 0228 www honeywellprocess com
4. Technical Information SCT 3000 Smartline Configuration Toolkit Model SCT 101 Specifications 34 CT 03 02 July 2013 Description The Smartline Configuration Toolkit is a PC based engineering and maintenance tool designed specifically for use with Honeywell s Smartline family of field instrumentation products The SCT 3000 is a Windows based software program that allows easy access to all Smartline configuration database parameters Familiar Windows tools are employed in the SCT 3000 for increased user productivity and include an on line user manual and context sensitive help for first time users The SCT 3000 version 5 11 302 runs on Windows 98 2000 operating systems and version 5 12 265 runs on Windows XP Windows Vista Ultimate and Windows Vista Business operating systems Function The SCT 3000 communicates with the following Honeywell Smartline products e ST 3000 Pressure Transmitters e STT 3000 Temperature Transmitters which include the STT150 STT250 and STT350 Series e SMV 3000 Multivariable Transmitters e MagneW and MagneW PLUS Electromagnetic Flowmeters Windows based displays Device database parameters are arranged and presented in logically grouped tab card displays Even the casual user can easily navigate through database configuration without the need for prior training user manuals or previous experience Will not communicate with older ST 3000 transmitters that are analog only and that
5. sired key number The arrow to the right marks the selection available e Make one selection from each table Il and Ill using the column below the proper arrow Adot e denotes unrestricted availability A letter denotes restricted availability Key Number l li DE __ f _ _ f xxxx Transmitter amp PC not included KEY NUMBER Description Smartline Configuration Toolkit TABLE 6 Ft Standard Cable Length 20 Ft No Cable Provided Inst Guide amp CD ROMs supports English German Installation Guide amp French Italian and Spanish Software CD ROMA Supports Windows 98 2000 CD ROMB supports Windows XP Vista TABLE II Options Modem 51453372 Tab with RS 232 Cable 50032086 001 TABLE Ill Factory Identification Note Softw are upgrades can be ordered through Honeyw ell Worldw ide Softw are Control Please e mail Sue Shea Accessories Part Number SCT 3000 Cable Kit and Installation Guide 50033453 501 Consult Honeywell s Order Entry System for current Parts Pricing Ordering Example SCT101 002 44 XXXX SCT 3000 Smartline Configuration Toolkit 6 Sales and Service For application assistance current specifications pricing or name of the nearest Authorized Distributor contact one of the offices below ASIA PACIFIC EMEA NORTH AMERICA SOUTH AMERICA TAC hfs tac Phone 80012026455 or 44 Honeywell Process Solutions Honeywell do Brazil amp Cia support honeywell com 0 12026
6. system capabilities needed to install and operate the SCT 3000 application PC Specification Computer Laptop or Desktop PC CPU Pentium 90 MHz or better Display SVGA Monochrome or Color Operating System Windows 98 2000 XP Vista or Windows 7 Pointing Device Mouse or trackball compatible device Power Source Battery powered See Note 1 Laptop PC AC powered See Note 1 Desktop PC RAM 16 MB 32MB recommended See Note 2 Application Size 12 MB application 5 kB per database file CD ROM Drive Laptop PC 4x or higher See Note 3 Desktop PC Ports Parallel Printer See Note 4 Serial For STT150 support and DE modem support for all the other devices See Note 3 USB Port For STT150 support and DE modem support in case the Serial port is not supported on the Laptop or PC See Note 5 1 Computer power source and laptop PC s battery charger and or AC adapter must be suitable for worldwide use 50 60 Hz and 100 220 VAC operation 2 Minimum RAM capacity is 4 MB but ROM based portable PCs may be able to run with only 2 MB 3 These functions require laptop PCs to have a CD ROM Drive serial port or other mechanism for file transfers installation of SCT 3000 software and updates e configuration database import and export 4 SCT 3000 software supports any Windows 98 or greater compatible printer 5 To use the SCT 3000 on a desktop or Laptop computer without serial port you must install USB to
7. ure a transmitter By providing responses to configuration questions and choices in a step by step progression you can configure the flow process variable in a Smart Multivariable Transmitter SMV 3000 Upon completion a configuration solution is generated by the wizard that can be downloaded to the field device Monitoring Graphical controls are employed so you can monitor the operating status of Smartline field devices A display window shows you values of input PVs output PVs and SVs of the connected device in real time Hardware and Software Included The SCT 3000 is a bundled package that includes the hardware and software to connect and communicate with Smartline field devices Standard hardware includes a DE Modem RS 232 Pass Thru Cable and connecting cables USB option is also available with DE Modem as an accessory item An optional RS 232 interface option ST is required when using the SCT 3000 application to communicate with the STT150 temperature transmitter NOTE DE Modem is a DE HART modem as it has the interface built in to support both DE and HART Host applications However SCT 3000 application supports only DE devices and it uses DE interface part of the modem SCT 3000 Smartline Configuration Toolkit 3 System Requirements The SCT 3000 software application runs on a variety of commercially available portable or desktop computer platforms that may also be shared with other applications This table lists the
Download Pdf Manuals
Related Search
Related Contents
3131 Controllore per riscaldamento RMH760 Manual de instalación para kit videoportero 2 hilos no HP ProCurve 6400cl-6XG Netgear WG102 Reference Manual emergency light range - GreenBrook Electrical FIELD APPLICATIONS OF SAFETY MANAGEMENT IN SMALL Miele CVA 3660 coffee maker Manuale ABE_1000 CableWholesale 6ft, C13 - C14 Copyright © All rights reserved.
Failed to retrieve file