1. lid operating handle shall be fitted with suitable grips of thermally insulating material The metal parts under the grips shall be completely covered so as no to come in contact with the operator Methods of operation of Sterilizer Electrical Operation Sterilizers shall be capable of operation on the heat sources detailed in 8 2 to 8 4 as selected by the purchaser and shall satisfy the requirements specified therein Electrically operated sterilizers shall have a single phase 3pin connection and the loading shall be large 1 5 kW An indicator lamp shall be provided on the sterilizer to indicate by glowing when the instrument is ON The entire electrical circuit shall be insulated from the sterilizer and the leakage current shall be not more than 210uA or 300HA when tested in accordance with IS 302 1979 It shall also be capable of withstanding a high voltage test of 1000V for one minute between any point of supply and earth Electrical Operation The wires used shall be heat resistant and the wiring shall be neatly laid out The minimum current carrying capacity of wire shall be 15A Heating Element Heating element shall conform to IS 4159 1983 It shall be of easily replaceable type and fitted with either built in ejector device or built in thermal cut out system The heating element shall operate on up to a maximum voltage of 250v single phase 50 Hz AC Thermostat Thermostat shall be capable of ensur
2. MSN amp UNOPS WEST BENGAL MEDICAL SERVICES CORPORATION LIMITED GoWB Through United Nations Office for Project Services 11 Golf Links New Delhi 110 003 INTERNATIONAL COMPETITIVE BIDDING FOR THE SUPPLY MEDICAL EQUIPMENTS FOR THE HOSPITALS AND MEDICAL COLLEGES OF THE GOVERNMENT OF WEST BENGAL UNOPS IFB No UNOPS IPO WBMSC EQUIP 01 2010 Amendment II dated November 12 2010 The following amendments are hereby made to the bid document for the supply of Medical Equipments for the Hospitals and Medical Colleges of the Government of West Bengal with reference to the above mentioned IFB 10 11 12 Technical Specifications Schedule 6 i Electric operated Autoclave 2 Drum Stand alone bench top autoclave 20 Litres automatic Single door self sealing with high quality silicone gasket Chamber diameter ca 25 cm depth ca 45 cm The autoclave should have double wall sheet metal with suitable insulation in between walls Pre set automatic cycles for unwrapped instruments wrapped instruments packs Slow exhaust and drying cycles Two automatic programmes approx 2 2 bar at 134 degree C and 1 1 bar at 121 degree C The equipment should have automatic pressure control switch automatic water control device to ensure that the equipment does not run dry Panel reports temperature pressure and time low water level as well as system errors f e door Temperature display should be digital and pressure display shou
3. air vents manually closed after sterilization 4 Thickness steel 0 8 mm 5 Diameter 10 1 6 Height 18 1 7 Device is produced by ISO 9001 certified manufacturer Certificate to be submitted Schedule 8 i INSTRUMENT STERILIZER MEDIUM Material Conforming to Designation 04Cr18Ni10 Design The sterilizer shall consist of a seamless shell having a hand operated lid at the upper end It shall be designed to operate on electricity gas or kerosene heat sources either independently or in combination as desired by the purchaser Dimensions The nominal inside dimensions of the shell shall be as given below subject to a tolerance of 2percent 430 mm L X 200 mm W X 150 mm H The thickness of the stainless steel sheet used for shell tray and lid shell be 0 90mm subject to the tolerances on thickness as specified in the relevant Indian standard However thickness of shell tray and lid shall not be less than 0 70mm at any place after drawing and for handle lever it shall be 3 00mm the minimum thickness for handle link connecting the handle lever and lid shall be 1 5mm Construction Construction The shell shall be pressed to form a seamless container The rim shall be so formed so as to prevent excessive steam escape Provision shall be made at the bottom of the shell to place it properly on the table The lid shall be made seamless dished and shall be designed to preven
4. entions spare parts and travel Schedule 6 ii Autoclave Single Drum Features Autoclave should be run on electric power having a dimension of at least 9 diameter and 11 height It should be made out of best quality aluminum gauze Locking system should be by turning and fixing lead into groove There should be a triple safety measure Gasket release safety valve and steam release a Capacity 11 litres b Sterilizing Sterilizing temperature should be 120 135 C Temperature Thickness Wall thickness of the inner chamber as well as lid should be of minimum 3mm Power Supply 230 10Volts 50Hz The apparatus should confirm to applicable IS standard with latest amendments or Standard equivalent international standards covering Markings Safety requirements with recommendations of safe operations Schedule 7 i Drum for autoclave 1 Stainless steel seamless cylindrical sterilizing drum 2 Austenitic stainless steel composition 8 to 10 nickel 18 to 20 chromium 3 Lateral air vents manually closed after sterilization 4 Thickness steel 0 8 mm 5 Diameter 7 0 5 6 Height 7 0 5 7 Device is produced by ISO 9001 certified manufacturer Certificate to be submitted Schedule 7 ii DRUM FOR AUTOCLAVE 1 Stainless steel cylindrical sterilizing drum 2 Austenitic stainless steel composition 8 to 10 nickel 18 to 20 chromium 3 Lateral
5. ing boiling water at sea level with a differential of 5 C Finish All stainless steel parts shall be finished smooth and polished bright or strain finish reasonably free from wrinkles and bulges The brass cock shall be plated chromium over nickel in accordance with service grade No 2 of IS 4827 1983 Marking Instruction manual The sterilizers shall be legibly and indelibly marked with the following a Identification mark of the manufacturer b Wattage voltage phase and cycle of electrically operated sterilizers c Not to be used in anaesthetizing sites and d Instrument does not give sterility Each sterilizer shall be accompanied by any instruction manual which shall contain information regarding instruction directions and operation of the sterilizer and Material Conforming to Designation 04Cr18Ni10 routine maintenance and service It shall contain instruction to use soft water to minimize scaling Packing As agreed to between the purchaser and the supplier before awarding the contract Schedule 8 ii INSTRUMENT STERILIZER SMALL Material Conforming to Designation 04Cr18Ni10 Design Dimensions The sterilizer shall consist of a seamless shell having a hand operated lid at the upper end It shall be designed to operate on electricity gas or kerosene heat sources either independently or in combination as desired by the purchaser The nominal i
6. ld be analogue Fit with 5 L water reservoir manual fill autonomy for at least 10 cycles Power shut off upon completion of cycle With 3 removable shelves Double safety door locking device Safety feature protect against over pressure and over temperature Audible and visual alert upon cycle interruption or completion 13 Unwrapped cycle time cold 30 min hot 20 min 14 Control panel with alpha numerical display and cycle indicators 15 Complete with 3 instruments trays 16 Power requirements 220 V 50 Hz single phase 17 Power consumption 3000 W 18 Device is produced by ISO 9001 certified manufacturer 19 Device is safety certified according CE 93 42 or FDA 510k or equivalent Supplied with 1 1x set of 3 matching instrument baskets 2 1x set of 3 matching sterilizing drums 3 1x roll of sterilization indicator TST control spots 4 1x box paper sheets crepe for sterilization pack 5 1x roll tape adhesive for sterilization pack 6 4 gaskets 7 1x spare set of fuses 8 User manual with trouble shooting guidance in English 9 Technical manual with maintenance and first line technical intervention instructions in English 10 List of priced accessories 11 List of priced spare parts 12 List with name and address of technical service providers in India 13 Training and installation at end user site 14 Proposal for full service AMC year 1 to 5 covering i 4 preventive maintenances per year ii on call technical interv
7. nside dimensions of the shell shall be as given below subject to a tolerance of 2percent 300 mm L X 150 mm W X 125 mm H The thickness of the stainless steel sheet used for shell tray and lid shell be 0 90mm subject to the tolerances on thickness as specified in the relevant Indian standard However thickness of shell tray and lid shall not be less than 0 70mm at any place after drawing and for handle lever it shall be 3 00mm the minimum thickness for handle link connecting the handle lever and lid shall be 1 5mm Construction Construction The shell shall be pressed to form a seamless container The rim shall be so formed so as to prevent excessive steam escape Provision shall be made at the bottom of the shell to place it properly on the table The lid shall be made seamless dished and shall be designed to prevent excessive steam escape and restrict the condensate within the shell but in any case it shall not buckle warp or twist with load The corners shall be rounded to suit those of the shell The lid shall open fully between 55 and 85 by single operation from its closed position A provision shall be made to connect the link end of the handle mechanism for simultaneous opening and closing of the tray and lid At the opening of the lid between 55 and 85 the tray shall be able to come to the top level of the shell A mechanism connected to the lid shall be such that when the lid is open a bracke
8. o indicate by glowing when the instrument is ON The entire electrical circuit shall be insulated from the sterilizer and the leakage current shall be not more than 210uA or 300HA when tested in accordance with IS 302 1979 It shall also be capable of withstanding a high voltage test of 1000V for one minute between any point of supply and earth Electrical Operation The wires used shall be heat resistant and the wiring shall be neatly laid out The minimum current carrying capacity of wire shall be 15A Heating Element Heating element shall conform to IS 4159 1983 It shall be of easily replaceable type and fitted with either built in ejector device or built in thermal cut out system The heating element shall operate on up to a maximum voltage of 250v single phase 50 Hz AC Thermostat Thermostat shall be capable of ensuring boiling water at sea level with a differential of 5 C Finish All stainless steel parts shall be finished smooth and polished bright or strain finish reasonably free from wrinkles and bulges The brass cock shall be plated chromium over nickel in accordance with service grade No 2 of IS 4827 1983 Marking The sterilizers shall be legibly and indelibly marked with the following e Identification mark of the manufacturer f Wattage voltage phase and cycle of electrically operated sterilizers g Not to be used in anaesthetizing sites and h Instrument does not give sterilit
9. t or rest for instruments tray shall bring the seamless tray well out of the water even when the water is at the highest level The tray bottom shall be perforated to allow easy drain out or entrance of water when the tray is being lifted or lowered in the sterilizer Handles shall be provided for handling the tray and the tray shall be convenient for fitting in or removal from the sterilizer When the tray is loaded as given below with load uniformly distributed the lid shall close slowly and without bang The tray shall be of such a design so as to take a total load of Large 40 N the depth of tray shall be Min 25mm Functional requirements A drain out connection shall be provided to facilitate draining of the sterilizer when desired The tap handle knob and lid operating handle shall be fitted with suitable grips of Material Conforming to Designation 04Cr18Ni10 thermally insulating material The metal parts under the grips shall be completely covered so as no to come in contact with the operator Methods of operation of Sterilizer Electrical Operation Sterilizers shall be capable of operation on the heat sources detailed in 8 2 to 8 4 as selected by the purchaser and shall satisfy the requirements specified therein Electrically operated sterilizers shall have a single phase 3pin connection and the loading shall be large 1 0 kW An indicator lamp shall be provided on the sterilizer t
10. t excessive steam escape and restrict the condensate within the shell but in any case it shall not buckle warp or twist with load The corners shall be rounded to suit those of the shell The lid shall open fully between 55 and 85 by single operation from its closed position A provision shall be made to connect the link end of the handle mechanism for simultaneous opening and closing of the tray and lid At the opening of the lid between 55 and 85 the tray shall be able to come to the top level of the shell A mechanism connected to the lid shall be such that when the lid is open a bracket or rest for instruments tray shall bring the seamless tray well out of the water even when the water is at the highest level The tray bottom shall be perforated to allow Material Conforming to Designation 04Cr18Ni10 easy drain out or entrance of water when the tray is being lifted or lowered in the sterilizer Handles shall be provided for handling the tray and the tray shall be convenient for fitting in or removal from the sterilizer When the tray is loaded as given below with load uniformly distributed the lid shall close slowly and without bang The tray shall be of such a design so as to take a total load of Large 40 N the depth of tray shall be Min 25mm Functional requirements A drain out connection shall be provided to facilitate draining of the sterilizer when desired The tap handle knob and
11. y Instruction manual Each sterilizer shall be accompanied by any instruction manual which shall contain information regarding instruction directions and operation of the sterilizer and routine maintenance and service It shall contain instruction to use soft water to minimize scaling Packing As agreed to between the purchaser and the supplier before awarding the contract All other terms and conditions of the bid document remain unaltered In case of any further information clarification they may contact UNOPS or WBMSC through e mail at procurementinoc unops org or wbmsc whbhealth gov in respectively individual visits in person to UNOPS or WBMSC offices shall not be entertained All requests for seeking clarification should cite the subject tender and should be received by the deadline indicated for the purpose above

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書  EU24/EU24BL Expansion Module User Guide  Le Plan local d`urbanisme maîtrise l`avenir d`Annemasse  INSTRUCTION MANUAL GUIDE D`UTILISA TION MANUAL DE  Operation Manual 02/2004  Pioneer DVR-310 User's Manual  Parrot PC000054AA car kit  Votre Esp@ce Famille…  MUSTEE 350WHT Instructions / Assembly  Whirlpool ED25DQXDB06 User's Manual  