Home
M102 New TOMOKO - sakamoto model corporation
Contents
1. the catheter apply the attached silicon oil to the catheter to increase smoothness 4 Moving joints unreasonably might lead to damage if anything abnormal is detected during use of the model notify us of it immediately 5 If somewhere on the model is sticky apply the accessory powder lightly Using the model without taking the necessary action might lead to breakage 6 Do not use the attached silicon oil on the epidermis of the injection model such as the attached Veinmate 2 7 Do not use pseudo tracheal cannula for humans 8 If anything strange is detected when this model is being used stop using it and notify us as soon as possible 9 This product is a simulator for users to perform advanced training Nonetheless it does not guarantee that a similar effect can be obtained by actual treatment 10 Note in advance that this product is subject to change without notice to improve it Usage This section describes procedures for the major practice items Read them to perform training 1 Muscle injection Intramuscle injection subcutaneous injection can be performed in the four total eight regions of the shoulders upper arms thighs and buttocks The pad is made of silicon including a sponge in it Bring the sponge out of the pad squeeze it and dry it in the shade Return it to the epidermis add the powder and replace it in position This is illustrated in the section on the storage meth
2. 72 729 8385 E mail trade sakamoto model com
3. M102 New TOMOKO S SAKAMOTO MODEL CORPORATION User s Manual 151020 Introduction Table of Contents 1 Purpose 2 Content 3 Precautions concerning handling 4 Usage 5 Storage method 8 7 For the usage of the attached Veinmate 2 refer to the user s manual of Veinmate 2 which is a separate manual packed together with this model Please open your parcel and check the main unit and accessories of the product immediately upon receipt If the products are delivered damaged or with parts missing please contact our company or the distributor AARAL SAE TIL Introduction Thank you for purchasing our product New TOMOKO Read this user s manual carefully in order to use the product for a long time appropriately This product is closely checked before factory shipment However when this product arrives open it soon and check if anything on the main unit and accessories are missing or broken Table of contents Introduction Table of Contents ccceceeeeeeeeees 1 PUDO Eana a a a a a 2 Conto tesr tae cecal ee A NTE EOE 3 Precautions concerning hand ling cceeeeeeeeeees 4 WGA Chilo ica cia cass che tiiuseteetaeedaeas a NNS 5 7 BLOPACS INCE O e a O aeons 8 For the usage of the attached Veinmate 2 refer to the user s manual of Veinmate 2 which is a separate manual packed together with this model Purpose Training can b
4. Sakamoto Suction Simulator 8 Urethral catheterization Take off the lid on the abdominal region to remove the tube for urethral catheterization Make sure that this tube is inserted into the tip of the irrigator s tube securely Hang the irrigator on the stand pour water into the bag and open the clamp Apply the lubricant oil to the catheter tip and insert it to train in urethral catheterization 9 Enema Apply the lubricant oil to the catheter and insert it at a low speed To prevent injected fluid from flowing backward the model is equipped with a valve in front of the rectum Although you will feel slight resistance when inserting the catheter fluids can be injected once it passes through the valve Do not perform enema using glycerin 10 Manual disimpaction Manual disimpaction training using this model is designed to learn the procedure Do not perform the training by inserting something like simulated stool because it might lead to the breakage of the epidermis It is possible to conduct training by attaching the separately sold M169 Fit on Manual Disimpaction Simulator 11 Shampooing Put the wig on and fix it with the accessory cord to train in shampooing Since the wig has artificial hair made of nylon do not use a hair drier to dry it with hot air Storage method 1 After training in intramuscle injection bring the sponge out of the pad squeeze the injection solution water only and dry i
5. e performed for the following items Posture change Intramuscular injection Intravenous injection blood sampling Oral hygiene Gastrostomy care Total parenteral nutrition Artificial anus care Tracheotomy care Nightwear change Carrying Whole body wiping Suctioning Urethral catheterization Nutrition oral nasal Enema Disimpaction Intestine gastric lavage Assisting excretion Restriction Fomentation Bandaging Shampooing Table of contents 1 Main unit 6 Baby powder 1 bottle 2 Veinmate 2 1 set 7 Exclusive Tape 2 pieces 3 Wig for shampooing 1 piece 8 Simulated gastric fistula catheter 1 piece 4 Pajamas 1 suit 9 Pseudo tracheal cannula 1 piece 5 Silicon oil 1 bottle 10 Catheter 1 set 14 Fr balloon catheter 10 mm gastric catheter nutrition catheter No 4 15EG Nelaton catheter 83EG Nelaton catheter 10 Replacement parts Sold Separately M102 1 Male Genitalia Model for New TOMOKO Accessories an irrigator and intestine Precautions Concerning handling 1 Do not put the model on print including newspapers because it is made of silicon and will easily become dirty or stained Clean dirt from the skin by wiping it gently using neutral detergents or alcohol based chemicals 2 Do not use any permanent markers or inks on the model because they will be absorbed into the skin and become impossible to remove 3 When inserting
6. od 2 Intravenous injection blood sampling When performing training set the accessory Veinmate 2 on the model For the usage of Veinmate 2 refer to the separate user s manual of Veinmate 2 packaged together with this model 3 Gastrostomy care The abdominal region is equipped with a stoma for gastrostomy Apply the lubricant oil before inserting simulated gastric fistula catheter Note that injecting fluids is not allowed 4 Total parenteral nutrition The model is equipped with a hole around the infraclavicular vein Apply the lubricant oil before inserting the tube Note that injecting fluids is not allowed 5 Artificial anus care The stoma part is bonded to the model Do not attempt to remove it from the main unit 6 Tracheotomy care Remove the silicon plug from the tracheotomy site and set the pseudo tracheal cannula for training After the training ends replace the silicon plug and store it 7 Catheterization suction urethral catheterization For each procedure use an applicable catheter Apply the lubricant oil and insert the catheter delicately After the training ends remove the lids on the chest and stomach region to dispose of the solution remaining in the stomach intestine and bladder directly Remove the bladder together with the external genitalia and tilt it to drain the water Suction training using simulated sputum is not allowed To perform such training use M175
7. t in the shade Then add the powder and replace the pad in position A 2 After using the model fit the chest and stomach lids to it securely and store them in the correct form 3 After using the stomach or intestine be sure to empty it out and dry it to the original state before storing the model 4 When the model gets dirty wipe off the dirt using a soft cloth with a neutral detergent After that wipe the model with a cloth moistened with water 5 Note that some silicon chemical might ooze and stain the nightwear if the model is stored without removing the nightwear 6 Lay the model with each joint stretched before storing it If there is more than one model do not pile them up but store them one by one 7 Ifthe epidermis is sticky be sure to apply the attached powder before storing the model 8 Do not use silicon oil on Veinmate 2 If silicon oil gets on the model by mistake wipe it off with a dry cloth before storing it Otherwise the quality of the epidermis might be degraded 9 Do not store the model anywhere that is exposed to direct sunlight or is hot and humid SAKAMOTO MODEL CORPORATION Head office 34 Higashitakagicho Shimogamo Sakyo ku KYOTO 606 0865 JAPAN Phone 81 75 701 1135 Fax 81 75 722 5638 E mail info sakamoto model com URL http sakamoto model co jp Overseas Sales Department 9 29 Senbahigashi Minoh City Osaka 562 0035 JAPAN Phone 81 72 729 8350 Fax 81