Contents
1. h Document Ref P0102 804 00 January 2015 Page 4 23 NALO LC Series Software Configuration amp System Calibration User Manual 122x32 Display 4 6 Inhibit The inhibit function allows channels to be disabled Channels may require disabling for several reasons e g a fault occurring on a channel to allow sensor replacement within the detector head to allow detector head calibration A disabled channel entering into a fault or alarm condition will result in no action being taken i e no relays will operate The disabled channel will appear on the System Default screen with OFF flashing next to the current reading The current reading is still displayed to assist with fault finding All other active channels will continue to operate normally The analogue output from the inhibited channel will go into fault mode i e output will equal lt 2mA or lt 0 5V depending on mode 1 From the System Configuration menu select INHIBIT and press GO 2 The Inhibit Options screen will now be displayed Note Pressing Exit at any time will return the display to the System Configuration menu 3 Using the NEXT button select the first channel to be inhibited press TOGGLE A yes or no will appear next to the channel indicating selection 4 Press EXIT when all of the channels requiring inhibiting have been selected 5 The system Warning screen will now appear Press YES to save settings or NO to abandon changes 6 The
2. Document Ref P0102 804 00 January 2015 Page 7 35 LC Series Software Configuration amp System Calibration User Manual 122x32 Display Connection Type The FLASH Development Toolkit can connect to your device in a number of different ways All the options on this page may be changed after the Project has been created Select Connection f BOOT Mode USER Program Mode Ketel already running z y Device Irnage E Target files E LCD mot ES Keybo rd m In BOOT Program mode the device erases its FLASH prior to connection The Toolkit downloads programming kemels to the device as required Device Image 5 ES Target Files m7 Drie Piot fat Draka moe E adgorithri The Recommended Speed setting is based on the current device and clock The user may also input their own if this is supported by the kemel and the interface board Use lv Default e User Specified lt Back Cance Use the default connection then press next Programming Options The FLASH Development Toolkit offers a device protection system plus an advanced messaging level for use with hardware and kemel development What level of device protection would yau like y Device Irmage E T i rs El il Target Files E LEB m t i Interactive None When programming the device any blocks found to have been 8 Keyboard Device Image 3 Target Files de Drive mot frDabapmol pl j ithe 15 Agonie written pr
3. LC Series Software Configuration amp System Calibration User Manual 122x32 Display 4 1 2 Fault delay This setting allows the LC system to ignore any readings taken that result in a fault condition The setting can be between 0 and 10 seconds 1 From the System Configuration menu select CONTROLLER and press GO 2 Next select the Start up Delay menu and press GO 3 Select the desired time delay using the INCrease and DECrease buttons 4 Press EXIT once adjustment has been made 5 The system Warning screen will now appear Press YES to save settings or NO to abandon changes The display will return to the Fault delay screen 6 Press EXIT twice the display will now return to the normal screen 4 1 3 Sounder This option is used to allow the user to verify that the internal sounder is operational and if necessary adjust its sound level by modifying its frequency of operation 1 From the ENGINEER menu select Sounder and press GO 2 The sounder setup menu screen will now be displayed Use the INC DEC buttons to select the frequency As the frequency is reduced the setting changes to always off then always on Press EXIT leave the setting as it was The display will now return to the Sounder menu Press EXIT The display will now return to the normal screen LA o ae Document Ref P0102 804 00 January 2015 Page 4 11 NALO LC Series Software Configuration amp System Calibration User Manual 122x32
4. LC Series Software Configuration amp System Calibration User Manual 122x32 Display Analox Ltd 15 Ellerbeck Court Stokesley Business Park North Yorkshire TS9 5PT UK T 44 0 1642 711400 F 44 0 1642 713900 W www analox net E info analox net The LC Series Manuals The LC range of environmental monitoring systems have a range of manuals covering various aspects of their operation e LC system installation and hardware configuration manual This manual covers all of the hardware aspects of the LC environmental monitoring systems Each of the component parts of the system is discussed and hardware configuration is explained Dimensional drawings are included of most of the LC variations e LC software configuration and system calibration manual The operation of the LC system is discussed as well as the software configuration and calibration procedures Note This manual is a generic manual for the latest firmware that is currently in use While every effort is made to maintain compatibility with older versions certain features and screen references may change when used in conjunction with different firmware versions The firmware version is displayed during power up and when the MENU key is pressed in later versions Document Ref P0102 804 00 January 2015 NALO LC Series Software Configuration amp System Calibration User Manual 122x32 Display List of Contents o 0 q Sameer ene ee se eee ee smn ee i
5. BIN FDT Binary Files CDE FOT DDI Files DDI FDT Image Files FPR IAR A20 Files 420 IAR A37 Files A37 Select the MOT file as shown above Now locate the file location via the Look in entry Add File s My Documents 4 Why Computer Jl 3 Poppy A e Local Disk C E WorkSpace Ey Low Cost Controller Bl2 4 Bl ese d CD Drive D a DWD RAM Drive E E Shared Documents E My Documents a My Network Places E Unused Desktop Shortcuts File name Add Files of ty Cancel NALO Document Ref P0102 804 00 January 2015 Page 7 38 LC Series Software Configuration amp System Calibration User Manual 122x32 Display Select the actual file then select Add as shown below Add File s Look in E release sl CSeriesV 10 LCSeresV100 mot 5 Record Files MOT Relative Path The following screen is shown LCController Flash Development Toolkit Unsupported Freeware Version File Edit View Project Tools Window Device Help Be elg al JAR R PAER E ETERA LICA Detant 2 Ae c i LCController E 43 S Record Files ES LCSeriesV1f 2llP1ash Development Toolkit and flash programming components are provided without support FDT API initialised version 4 01 00 010 4 FDT LCController Document Ref P0102 804 00 January 2015 Page 7 39 NALO LC Series Software Configuration amp System Calibration User Manual 122x32 Display
6. Document Ref P0102 804 00 January 2015 Page 4 16 LC Series Software Configuration amp System Calibration User Manual 122x32 Display 4 2 4 2 Analogue output Connect a multimeter to the analogue output select an appropriate range depending upon the channel configuration From the System Configuration menu select CHANNEL and press GO Select the appropriate channel number and press GO Select Calibration and press GO Select Analogue output and press GO The following screen will now be displayed ON LON 6 Press the INCrease DECrease buttons to adjust the output to 4 mA or 1V 7 Press the NEXT button Press the INCrease DECrease buttons to adjust the output to 20 mA or 5V Press the NEXT button O The system Warning screen will now appear Press YES to save settings or NO to abandon changes 11 The display will now return to the Analogue output menu 12 Press EXIT The display will now return to the normal screen Document Ref P0102 804 00 January 2015 Page 4 17 NALO LC Series Software Configuration amp System Calibration User Manual 122x32 Display 4 2 4 3 Power supply Each channel has a variable power supply that can be adjusted between 0 and 24 volts This allows the user to set the supply to match the external device The power calibration voltage is displayed on the display during set up This voltage is set to the actual measured voltage Note lt may be necessary
7. LCContraller Project Name LCContraller Directory C Program Files Renesas FO74 017 WVorkspa Browse CPU family al Flash Devices Tool chain Properties Enter the workspace name in the above example LC Controller then press OK Document Ref P0102 804 00 January 2015 NALO Page 7 34 LC Series Software Configuration amp System Calibration User Manual 122x32 Display Choose Device And Kernel The FLASH Development Toolkit supports a number of Renesas FLASH devices Select the device you wish to use with this project from the list below Filter Kemel Version R5F21245 R5F21246 R5F21247 R5F21248 R5F21254 R5F21255 R5F21 256 R5F21257 ml mk mal mk k mk mk SSsssooas R5F21 258 A m R5F21262 R5F21264 p omi a l l wt Es The FLASH Development Toolkit supports connection through the standard PC Serial port and the USB port Use this page to select your desired communications port All settings may be changed after the project is created d Device Irna i mi L ge o A Ea Target Files a E LEE met l ES Keybeard nm 115 Corn mt E En Motor Control Select an Interface type to connect to the target device with a 3 D vice Image Normal this will be Direct Connection or simply left blank aa Target Files es Drive mat Daba fret Select Interface f by am En algorithrnT A Select the E8a port then press next
8. Now double click the programming file by double clicking the mot file The following screen will be displayed gt File Edit View Project Tools Window Device Help CA oT es e aarre er ao oe fp Ape AA Z be abe A A 00004000 13 El LCController ooo04010 60 f LCController 00004020 31 Ey S Record Files 00004030 OE TESTIT 00004040 EE 00004050 31 00004060 16 00004070 F 00004080 CE 00004090 De 00004040 22 00004060 B2 0000400 Ae 00004000 93 000040E0 385 QOOOO040FO0 665 00004100 79 00004110 54 User Flash LCSeresV10 a e ao X Flash Development Toolkit and flash programming components are provided without support FDI API initialised version 4 01 00 010 Opening file C WorkSpace Low Cost Controller lc 4 release LCSeriesv100 mot File loaded 0x00004000 gt Ox00013FFF User Flash File loaded 0x00002400 gt Ox00002BFF Data Flash ID Code OxFF OxFF OxFF OxFF OxFF OxFF OxFF 4 f FDT LCController A Findin Files Ba Disconnected Notice the right hand panel displays program data Now save the project by selecting File Save Workspace A Edit View Project Tools Win Close New Workspace Open Workspace Save Workspace Close Workspace S Open Data File Ctrl R A Save Ctrl 5 save AS Recent Workspaces Recent Data Files Exit N A LO Document Ref P0102 804 00 January 2015 Page 7 40 LC Series Software Configuration amp System Calibration User Manu
9. alerted if the oxygen levels fall below 19 5 in this instance we would set the alarm as FALLING 7 Press EXIT once the alarm levels have been selected 8 The system Warning screen will now appear Press YES to save settings or NO to abandon changes 9 The display will now return to the Alarm Level menu 10 Repeat for the next alarm level Document Ref P0102 804 00 January 2015 Page 4 14 NALO LC Series Software Configuration amp System Calibration User Manual 122x32 Display 4 2 2 Alarm delay Each channel has two configurable alarm delays Ve SN oe 4 2 3 From the system configuration menu select CHANNEL and press GO Select the appropriate channel number and press GO Select Alarm delay and press GO Select the alarm level and press GO The Alarm Delay screen will now be displayed Press INCrease or DECrease until the desired delay is displayed Press EXIT The system Warning screen will now appear Press YES to save settings or NO to abandon changes The display will now return to the Alarm delay level menu Repeat for the next alarm level Alarm hysteresis Each channel has a hysteresis value associated alarm relays This setting is used to eliminate relay chatter when the gas level hovers around alarm set point IA A O y Document Ref P0102 804 00 January 2015 Page 4 15 From the System Configuration menu select CHANNEL and press GO Select the appropriate channel number
10. and press GO Select HYSTERESIS and press GO The Hysteresis screen will now be displayed Press INCrease or DECrease until the desired hysteresis is displayed Press EXIT The system Warning screen will now appear Press YES to save settings or NO to abandon changes The display will now return to the Alarm hysteresis menu NALO LC Series Software Configuration amp System Calibration User Manual 122x32 Display 4 2 4 Calibration Each channel has three calibration possibilities these are 1 Sensor 2 Analogue output 3 Power supply 4 2 4 1 Sensor From the system configuration menu select CHANNEL and press GO Select the appropriate channel number and press GO Select Calibration and press GO Select Sensor and press GO The following screen will now be displayed O A 6 Press the ZERO button to zero the sensor Make sure that the sensor is on zero gas before performing the zero function 7 Press the NEXT button 8 Apply the test gas The reading should rise to approximately that of the gas level 9 When the reading is stable press the SPAN button to calibrate the sensor The Span button may be pressed repeatedly until the reading and span gas match 10 Press EXIT The system Warning screen will now appear Press YES to save settings or NO to abandon changes 11 The display will now return to the Sensor menu 12 Press EXIT The display will now return to the normal screen NALO
11. to measure the voltage at the device if it a long way from the control unit Connect a multimeter to the variable PSU output select a range that will display up to 30V dc From the system configuration menu select CHANNEL and press GO Select the appropriate channel number and press GO Select calibration and press GO Select power supply and press GO The following screen will now be displayed eee 6 Press the INCrease DECrease buttons to adjust the displayed reading output to match the measured level Press the SPAN button when the display matches the measured level Press the EXIT button The system Warning screen will now appear Press YES to save settings or NO to abandon changes 10 The display will now return to the Calibration Power supply menu 11 Press EXIT until the display returns to the normal screen oo Document Ref P0102 804 00 January 2015 Page 4 18 NALO LC Series Software Configuration amp System Calibration User Manual 122x32 Display 4 3 Set voltage Each channel has a variable power supply that can be adjusted between 0 and 24 volts This allows the user to set the supply to match the external device The power supply voltage is displayed on the display during set up however the displayed voltage is dependent upon the load connected to the supply and may not read exact The display voltage can be calibrated for any given load see section 4 2 4 3 Note lt may be neces
12. 0 00004100 mem AO LCSeriesV 10 AlVersion Information VER 1 00 E Changing baud rate to 500000 bps ID code check successful Connection complete Lock Bit Disabled 411 blocks marked as unknown written status lt 4 FDT LCController A Find in Files Pa Disconnect es Erase FLASH Blocks Ctrl Alt E ES Blank Check Ctrl Alt B gF Upload Image Ctrl Alt U sg Download Active File Ctrl Alt P FLASH Checksum Ctrl alt s Be Go From Address Ctrl Alt 6 Ctrl Alt R Alt Shift R Document Ref P0102 804 00 January 2015 Page 7 42 LC Series Software Configuration amp System Calibration User Manual 122x32 Display The programming progress is displayed with the final display shown as below LCController Flash Development Toolkit Unsupported Freeware Version LCSeriesV100 mot Big Endian gt File Edit View Project Tools Window Device Help a s we aa JA amp 8 WAPA eer Sh wel e a o ETE pP A OOO04000 19 El LCController 00004010 460 LCController 00004020 31 Q 43 5 Record Files 00004030 DE A MT 00004040 EE 1 EST 00004050 31 00004060 16 00004070 F 00004080 CB 00004090 De OOO040a0 Ce QOUU40B0 E2 OOO040C0 A 00004000 93 o000040E0 85 O00040EF0 665 00004100 79 00004110 54 Som AO AllWriting image to device 0x00004000 Ox0000DCFF Writing image to device Ox0000FE00 Ox000113FF Data programmed at the following positions Ox0000DCFF Len
13. Display 4 1 4 Decimal point This option is used to allow the user to select the numerical display according to the location 1 From the ENGINEER menu select Decimal point and press GO 2 Use the TOG buttons to select the decimal point or the comma 3 Press EXIT leave the setting as it was 4 The display will now return to the Decimal point menu 4 1 5 Backlight This option is used to allow the user to set the backlight operation The backlight can be set to activate when a button is pressed for a pre determined time It can also be set to be continuously on or off allowing total flexibility in its use 1 From the ENGINEER menu select Backlight and press GO 2 Use the INC DEC buttons to select the required time 3 Press TOG to change the mode between timed always on and always off 4 Press EXIT when the desired setting is selected 5 The display will now return to the Backlight menu Note Some displays require that the backlight is on continuously Document Ref P0102 804 00 January 2015 Page 4 12 NALO LC Series Software Configuration amp System Calibration User Manual 122x32 Display 41 6 Password This option is used to allow the user to set the user password The password can be from 0 to 8 digits long and must only contain the numbers 1 2 and 3 1 From the ENGINEER menu select password and press GO Use the 1 2 or 3 buttons to select the required password Press GO when the desired nu
14. EXT NEXT GO Analogue output 4mA NEXT NEXT Power supply a Set voltage 0 to 10V Calibrate output NEXT Sensor Type L Type E Fsd 2 Units PS Decimal places NEXT NEXT Fsd 1 to 20 NEXT NEXT Decimal places NEXT Relays ie Select relay NEXT tes NEXT a GO Inhibit Enable disable NEXT NEXT Engineer JP NEXT Analogue output NEXT Input simulation Document Ref P0102 804 00 January 2015 Page 4 9 NALO LC Series Software Configuration amp System Calibration User Manual 122x32 Display 4 1 Controller The controller menu has 6 menu options as follows 1 Start up delay 2 Fault delay 3 Sounder 4 Decimal point 5 Backlight 6 Password The following section details each menu option 4 1 1 Start up delay This setting allows the LC system to ignore any readings taken following the transition following applying power The setting can be between 0 and 180 seconds 1 From the System Configuration menu select CONTROLLER and press GO 2 Next select the Start up Delay menu and press GO 3 Select the desired time delay using the INCrease and DECrease buttons 4 Press EXIT once adjustment has been made 5 The system Warning screen will now appear Press YES to save settings or NO to abandon changes 6 Press EXIT The display will return to the Start up delay screen 7 Press EXIT The display will now return to the normal screen Document Ref P0102 804 00 January 2015 Page 4 10 NALO
15. al 122x32 Display 7 2 Programming the LC controller Launch the PC programmer default location is typically C Program Files Renesas FDT4 01 FDT exe Open the project as described in section 7 1 Connect to the LC Controller by selecting Device Connect to device sal Connect to Device Ctrl Alt C iri Erase FLASH Blocks Ctrl Alt E pps Blank Check Cil Alt4E Upload Image Ctrl Alt u Download Active File Cirl alt4 P FLASH Checksum Ctrl Alt 5 7 Configure Flash Project Alt Shift h The following screen is show Target Power from E8 E8a Please select whether the ESE Sa should power the target this setting will be retained until the project i closed Cancel kW Power Supply The LC Controller can be powered from the programmer as shown above Press OK The following screen is show Select USB Device 1 USB device located Cancel Now press OK Document Ref P0102 804 00 January 2015 Page 7 41 LC Series Software Configuration amp System Calibration User Manual 122x32 Display The lower panel should confirm that the Programmer has successfully opened dialog with the LC Controller as seen below Ji File Edit View Project Tools Window Device Help his JA v Al Fee eT Sv wel H lo e e Joe Deia 2 a LCCaontroller LCController 4 3 S Record Files Am 00004040 00004050 00004060 0000400 00004080 00004090 00004040 000040860 0000400 00004000 OD00D040E0 OO0040F
16. ay 4 8 Engineer This menu is provided to allow Analox Ltd personnel or trained personnel to verify the correct operation of the hardware This option is accessed via the ENGINEER option in the main menu screen An additional password is required to enter this menu option The password can be obtained from Analox Ltd 4 8 1 Devices This option is used to allow the user to verify that the relays sounder and indicators are operating correctly 1 From the ENGINEER menu select sound and press GO 2 The Hardware test menu screen will now be displayed 3 Use the PREV NEXT buttons to set the desired option Sound L1 Led L2 Led L3 led Fault led Relay 1 Fault etc 4 Use the TOG button to activate deactivate the selected option Press EXIT when the tests have been completed The display will now return to the ENGINEER menu 6 Press EXIT The display will now return to the normal screen Document Ref P0102 804 00 January 2015 Page 4 26 NALO LC Series Software Configuration amp System Calibration User Manual 122x32 Display 4 8 2 Analogue output This option is used to allow the user to verify that the analogue output is working correctly Connect a multimeter to the analogue output 1 From the ENGINEER menu select ANALOGUE OUTPUT and press GO Use the NEXT button to select the channel Use the INC DEC buttons to increase decrease the analogue output level Press EXIT when the tests have been complete
17. ccoooncncccnccnnccnncnnccnanoncnnoncnnononcnnnonannnnnnnnrnnnnnnrnnnonannnnnnanrnrenaneos 6 29 7 Firmware update AA e Pe O CE 7 34 7 1 Creating a NEW prOjOCt cooonccnncccconnconccononncnncnononnnononnnancnnnonnnnncnnnnnnnnnrnnnnnnannrnnnnnnanens 7 34 7 2 Programming the LC controller oooccccccccnnncnncccccnnnnnononanonnnnonnnncnnnnnnnnnnnncnnnnnnnns 7 41 Document Ref P0102 804 00 January 2015 NALO LC Series Software Configuration amp System Calibration User Manual 122x32 Display 1 Introduction The LC range of environmental monitoring systems has been designed primarily with gas detection in mind However the versatility of the range extends its application to other aspects of industry where monitoring of remotely connected sensors is required The specification allows the use of any sensor that can produce a voltage or current output within a specified range 1 1 Software The firmware software within each of the control units has had to be carefully designed to allow the full potential of the system to be utilised In many cases the software is identical between the different control units but configuration changes have allowed the system to be used for completely different applications Incorrect configuration may cause the system to function unsatisfactorily and in extreme cases of incorrect configuration alarms would not be raised Analox Ltd are happy to offer advice when configuration changes become nec
18. d The display will now return to the ENGINEER ACCESS menu ooo 4 8 3 Input simulation This option is used to allow the user simulate a sensor output under normal operation Note if the simulated sensor output rises above an alarm set point then the system will generate alarm etc as per the system configuration 1 From the ENGINEER menu select Input simulation and press GO 2 Use the NEXT button to select the channel Use the INC DEC buttons to increase decrease the sensor level If the alarm levels have been reached then the display will show the alarm level the corresponding relay will be activated and the leds will flash 4 Press EXIT when the tests have been completed The display will now return to the Input simulation menu Document Ref P0102 804 00 January 2015 Page 4 27 NALO LC Series Software Configuration amp System Calibration User Manual 122x32 Display 5 System reset The system may be reset by removing power waiting for 20 to 30 seconds then re applying power 5 1 Soft reset The LC series control units can be reset without removing the power This is achieved by pressing a combination of buttons on the front panel as follows 1 Press and hold the middle two un marked buttons 2 Now hold both buttons for approximately 10 seconds Note The bar graph shows the remaining time to reset the LC Controller if the keys are released before the bar graph reaches the end then the controlle
19. d in excess of those set in the alarm levels configuration in the above example 15 LEL the LC Control Unit will raise an alarm The way in which the alarm is raised will depend upon the system configuration and the ancillary sounders and beacons fitted to the system Note An alarm will be indicated on the display by the word Alarm appearing next to the channel in alarm the Alarm status will flash and indicate the alarm level The local Alarm Red LEDs will light to indicate an Alarm condition regardless of the display mode selected 3 2 2 Fault alarm The control unit will indicate a fault if a detector head indicates less than 10 of its measuring range i e below 2 4mA signal level Any channel that is in a fault condition is detected by the LC control unit which generates a fault message drives the local Yellow LED and activates the fault relay 3 2 3 Accepting the alarm If an alarm condition is encountered and The alarm relays are set as non latching Pressing alarm accept suton A will allow the sounder to be silenced When the alarm condition has passed the relays will reset themselves to their healthy state Document Ref P0102 804 00 January 2015 Page 3 5 NALO LC Series Software Configuration amp System Calibration User Manual 122x32 Display The alarm relays are set as latching Pressing alarm accept suton A will allow the sounder to be silenced The Alarm will only be cleared if the Button is pr
20. display will now return to the Inhibit Channel menu 7 Press EXIT The display will now return to the normal screen Important Do not forget to enable the channel once fault rectification or sensor replacement has been performed Document Ref P0102 804 00 January 2015 Page 4 24 NALO LC Series Software Configuration amp System Calibration User Manual 122x32 Display 4 7 View The View function allows channels to be hidden Channels may require hiding for several reasons e g only 3 sensors fitted to a 4 channel system A channel that is hidden will still function as an active channel unless it is inhibited 1 From the System Configuration menu select INHIBIT and press GO 2 The Inhibit Options screen will now be displayed Note Pressing Exit at any time will return the display to the System Configuration menu 3 Using the NEXT button select the first channel to be inhibited press TOGGLE A yes or no will appear next to the channel indicating selection 4 Press EXIT when all of the channels requiring inhibiting have been selected 5 The system Warning screen will now appear Press YES to save settings or NO to abandon changes 6 The display will now return to the Inhibit Channel menu 7 Press EXIT The display will now return to the normal screen Document Ref P0102 804 00 January 2015 Page 4 25 NALO LC Series Software Configuration amp System Calibration User Manual 122x32 Displ
21. display will then change to the System Default Screen see section 3 This lists details associated with all configured channels Document Ref P0102 804 00 January 2015 Page 3 3 NALO LC Series Software Configuration amp System Calibration User Manual 122x32 Display 3 1 Accessing the system configuration menu All of the features provided by the LC software are accessed from the system configuration menu To access the system configuration menu 1 Press menu from the system default screen 2 The Password Entry screen will appear if the password is set MENU XK 3 Enter the correct password and press OK 4 The default password for the system is 123 If an incorrect password is entered the system will revert to the standard system default screen 5 The following screen will be seen when the correct password Is entered 3 2 Alarm conditions 3 2 1 Gas level alarm Gas level alarms can be of two types 1 Level 1 alarm 2 Level 2 alarm 3 Level3 alarm not available on LC1 3 2 1 1 Level 1 alarm The LC control unit has stored within its configuration gas levels at which alarms should be raised e g Channel 3 may be detecting methane 0 to 100 LEL Its alarm levels may be set as 15 30 LEL and 50 LEL Document Ref P0102 804 00 January 2015 Page 3 4 NALO LC Series Software Configuration amp System Calibration User Manual 122x32 Display Each time a gas concentration is detecte
22. eee ee ee ee eee eee eee 1 2 O SONWANE ee E e ee ee 1 2 2 OWCA Oia 2 2 SA O aa A E EE E 3 3 3 1 Accessing the system configuration MENU oooccncccnncnnccnnnnncononcnnononennnnonrnnonnnnnncnnanennos 3 4 232 o AA e PE E PS E PO IIA 3 4 Get E SA 3 4 A RI ag sao acess ees ode sas i a acne edo i ea 3 5 323 PCCCDUNG TC AIA restrictions a aa iE 3 5 2 ISI SC NG arsenal 3 6 P PP es oaenes eas nayatancine 3 6 34 Changing Me pass Word insignia sados ita ic 3 7 Ar SOlWare COMMOUN ANON sees dit 4 8 Wi COn Tole ninio io ocio 4 10 NS o A eee eer ee are ee ee 4 10 A FU OAV a ec he A ean a eee ee eee eter ee earner 4 11 AS SOUND ni tas 4 11 4 1 4 Decimal point ASAS A 4 12 ao D gig bara a E A A E A 4 12 210 PFa WOO seare E E E E EER T EE E a 4 13 SA a E E E E E E E EE E A ET 4 14 a A a 4 14 2 O AA 4 15 Aa A e eE o o E A 4 15 A Sn PA 4 16 A A 4 19 E oa 4 20 4 4 1 Special Sensor Type No sssccccccccccccssseceeeeccsscesseeeseecceseessseceeeecessssaaeeeseeeeeseaas 4 21 AO Aa AU Pr o E POC PO RA 4 22 4 5 1 Level3 alarm relayS ooccccconcnnccccononococononoconnonncnanonnonnnonnnnnnnnnnnannnnorannnnnnnanannnns 4 23 AO O PPP o o A e A 4 24 A o a 4 25 do ENOINSO sonando 4 26 BL XA 4 26 4 8 2 Analogue OUTDUL cccscccccsseeeccnseeeccnssuseecsausecenscsesensauscessaueuetsaauesensauesensanssessanes 4 27 48 3 ANPUESIMII ANO iria di ic 4 27 VSS Mn cet hen A PP o ooo A 5 28 A O nn 5 28 6 PC programming software
23. els should be inhibited and the viewing attribute should be disabled Document Ref P0102 804 00 January 2015 Page 4 21 NALO LC Series Software Configuration amp System Calibration User Manual 122x32 Display 4 5 Relay options Each of the two relays has user configurable options available to them 1 From the System Configuration menu select Relays and press GO 2 Select the appropriate relay number and press GO Notice that the arrow key points to the setting that will be changed when TOG is pressed Pressing NEXT will move the arrow to the next option The buttons are re defined when the DELAY option is selected This allows the value to be changed 3 Press EXIT when the desired readings are set 4 The system Warning screen will now appear Press YES to save settings or NO to abandon changes 5 The display will now return to the Relay menu 6 Press EXIT The display will now return to the normal screen The relay options are MODE N D or N E This refers to the state of the relay under normal no alarm conditions i e N D Normally de energised N E Normally energised ENABLED YES or NO Refers to whether the relay will change state if an alarm condition is encountered NALO Document Ref P0102 804 00 January 2015 Page 4 22 LC Series Software Configuration amp System Calibration User Manual 122x32 Display LATCH YES or NO Latching non latching refers to how the relay reacts
24. essary to ensure a reliable and responsive system is maintained 2 Switch on Before connecting power to the system 1 Read LC series system installation and hardware configuration manual LC series software configuration and system calibration manual 2 Ensure correct hardware configuration has been performed for each input 3 Ensure the correct voltage setting has been selected at the power supply Switch on the power supply to the system The firmware version will appear for several seconds on the LCD graphical display A bar graph will be displayed during the system power up delay setting as follows The display will then change to the System Default Screen see section 3 This lists details associated with all configured channels Document Ref P0102 804 00 January 2015 Page 2 2 NALO LC Series Software Configuration amp System Calibration User Manual 122x32 Display 3 Operation Before connecting power to the system 4 Read LC series system installation and hardware configuration manual LC series software configuration and system calibration manual 5 Ensure correct hardware configuration has been performed for each input 6 Ensure the correct voltage setting has been selected at the power supply Switch on the power supply to the system The firmware version will appear for several seconds on the LCD graphical display A bar graph will be displayed during the system power up delay setting as follows The
25. essed and the alarm is no longer in an alarm condition MENU X 3 3 Display settings The LCD display can be configured to display the gas levels using either the decimal point or the comma The display can also be set to give an additional message during alarm and fault conditions This is useful when different languages are used and the text cannot be clearly displayed in the normal 5x8 character size The amount of time the backlight remains lit following a key press is also user configurable 3 3 1 Backlight time The LCD display is provided with backlight illumination following a key press The default backlight on time is 10 seconds This time is user configurable between ALWAYS ON ALWAYS OFF and any time up to 600 seconds To change the backlight time 1 From the System Configuration menu select BACKLIGHT and press GO 2 The Display Configuration screen will now be displayed Use the INCrease and DECrease buttons to adjust the backlight on time Attempting to decrease the backlight time below 1 second will provide the options of ALWAYS ON and ALWAYS OFF 3 The system Warning screen will now appear warning you that you are making changes to the system configuration Press YES to save the changes or press NO to abort the changes and return to the main system menu Document Ref P0102 804 00 January 2015 Page 3 6 NALO LC Series Software Configuration amp System Calibration User Manual 122x32 Display 3 4 Chan
26. eviously will automatically be erased What level of messaging would you like Messaging Standard The Toolkit will display verbose messages whenever it is communicating with the Target device This mode is useful for Interface hardware development and Kemel development Cancel Select Automatic and advanced then press Finish Document Ref P0102 804 00 January 2015 Page 7 36 NALO LC Series Software Configuration amp System Calibration User Manual 122x32 Display The following screen will be shown LCController Flash Development Toolkit Unsupported Freeware Version File Edit View Project Tools Window Device Help U eeg a JA g R P A F E AEREA IA EA ET E Allrlash Development Toolkit and flash programming components are provided without support FDI API initialised version 4 01 00 010 4 FDT LCController Ready E a Disconnected UCP OFF E Now add the program file by selecting Project Add files Window Device al Tools set Current Project Insert Project Remove Files File Extensions Rebuild Image Field Programming Document Ref P0102 804 00 January 2015 Page 7 37 NALO LC Series Software Configuration amp System Calibration User Manual 122x32 Display Add File s Look in E LCController de Default File name Cancel Files of type S Record Files MOT Binary Files
27. ging the password The system configuration menu can only be accessed following correct password entry The default password is 123 however this can be changed To change the password 1 From the system configuration menu select PASSWORD and press GO 2 The Password Configuration screen will now appear 3 Enter the new password and press OK The password can contain a maximum of 8 numbers a minimum of none Note Pressing EXIT at any time will cancel the current operation 4 You will then be prompted to confirm the new password Re enter the password and press OK Note If a different password is entered at this stage no settings will be saved and the old password will remain active 5 The system Warning screen will now appear Press YES to save settings or NO to abandon changes 6 The display will now return to the System Configuration menu Note Entering no digits will disable the user password Note Forgotten password The user password can be overridden by the engineer password contact Analox Ltd Document Ref P0102 804 00 January 2015 Page 3 7 NALO LC Series Software Configuration amp System Calibration User Manual 122x32 Display 4 Software configuration The software configuration has been made as flexible as possible in order to maintain capability with the many types of sensors available and the wide variety of possible applications Many options are included within the software t
28. gth 0x00009D00 0x000113FF Length 0200001600 44 75 K programmed in Y seconds Image successfully written to device 4 i FDT LCController Find in Files Connect to FA Disconnect es Erase FLASH Blocks Ctrl Alt e ES Blank Check Ctrl Alt 8 Upload Image Ctrl Alt U Download Active File Ctrl Alt P E FLASH Checksum Ctrl Alt S ge Go From Address Ctrl Alt 6 Ctrl Alt R fF Configure Flash Project Alt Shift h Document Ref P0102 804 00 January 2015 NALO Page 7 43
29. h Licensed Software be executed Do you accept all the terms of the preceding License Agreement If you select No the setup will close To install E8a Emulator Software you must accept this agreement InstallShield lt Back Yes ko Read the terms and conditions then select Yes Document Ref P0102 804 00 January 2015 Page 6 31 LC Series Software Configuration amp System Calibration User Manual 122x32 Display E8a Emulator Software V 1 00 Release 00A Region Selection Select the region Europe or United States of America Y Other region Japan Asia etc InstallShield lt Back Next gt Cancel Select the region then press Next E8a Emulator Software V 1 00 Release ODA Select Features Select the features setup will install Select the features you want to install and deselect the features you do not want to install en oe 9 High performance Embedded Workshop oe High performance Embedded Workshop Online 740 Family 9 7 H85 H85 H8 Family 6 7M32C 90 80 M16C 80 70 Series Sm M16C 60 30 Tiny 20 10 R8C Tiny Series 9 M16C Toolchains gt MMI6C R8C Tiny Series Simulator Debugger i M ASC Esa Emulator Debugger 7 M16C E8a Emulator Debugger gg 740 Family 9 E8a Self Check Program InstallShield lt Back Next O conce Select the above options then press Next then Next E8a Emulator Software V 1 00 Release OOA Site Code Please retain this code as it will be requested whe
30. h performance Embedded Workshop InstallShield Wizard Choose Setup Language Select the language for the installation from the choices below InstallShield Select the language then press Next E8a Emulator Software V 1 00 Release ODA Welcome to the InstallShield Wizard for E8a Emulator Software The InstallShield Wizard will install E8a Emulator Software on your computer To continue click Next InstallShield Select Next E8a Emulator Software V 1 00 Release OOA License Agreement Please read the following license agreement carefully Press the PAGE DOWN key to see the rest of the agreement Licensed Copy Number 1 Copy Software User License Agreement The customer hereafter referred to as Licensee and Renesas Technology Corp hereafter referred to as Licensor do hereby agree to the terms and conditions as specified in this Software User License Agreement hereafter referred to as Agreement concerning the enclosed software and its explanatory manuals ARTICLE 1 Definition 1 1 Licensed Software shall mean the main unit of the software tools and related executable programs the Library as defined in Section 1 4 below and documentation such as explanatory manuals and all other related materials 1 2 Designated System shall mean the computer system to which Licensed Software be installed In case of Network environment system Designated System shall mean the computer system to whic
31. isplayed This screen allows the user to choose the operating range of the sensor The default values for the sensor will be displayed Important It is vital that the FSD values selected at the control unit IS identical to that of the detector head The FSD value is the reading that corresponds to the head drawing a current of 20mA Document Ref P0102 804 00 January 2015 Page 4 20 NALO LC Series Software Configuration amp System Calibration User Manual 122x32 Display Press GO once the correct sensor range has been selected The Sensor Units screen will now be displayed This screen allows the user to choose the units of the sensor Available units are ppb C F lel ppm Press GO once the correct sensor units have been selected The following screen is displayed Select the appropriate display type by using the PREVious and NEXT buttons then press GO The system Warning screen will now appear Press YES to save settings or NO to abandon changes The display will now return to the Sensor Type menu Press EXIT The display will now return to the normal screen A calibration must now be performed 4 4 1 Special Sensor Type N2 The sensor type can be specified as N2 Nitrogen The gas level is not actually measured but assumed to be 100 the measured gas levels of the previous enabled channels A typical display is as follows Note All channels must be configured to be v v Unused chann
32. mber has been entered Confirm the password then press GO The display will now return to the Password menu Qa Note The password can be disabled by setting the password to 0 no numbers entered when setting Document Ref P0102 804 00 January 2015 Page 4 13 NALO LC Series Software Configuration amp System Calibration User Manual 122x32 Display 4 2 Channel The channel menu has 9 menu options as follows Alarm levels Alarm delay Alarm hysteresis Calibration Set voltage Sensor type Fsd Units Decimal places it PLA a ae The following section details each menu option 4 2 1 Alarm Levels Each channel has two configurable alarm levels From the System Configuration menu select CHANNEL and press GO Select the appropriate channel number and press GO Select ALARM LEVELS and press GO Select the alarm level and press GO The Alarm Levels configuration screen will now be displayed MAIN 6 Press INCrease or DECrease until the desired alarm level is displayed Press TOG as required to set the alarm as RISING or FALLING Note RISING and FALLING refers to the triggering condition for the relay A flammable head will read O LEL under normal conditions and we would therefore need to be alerted if the gas levels rise above predetermined levels In this instance we would set all alarms as RISING alarms If we consider an oxygen head that would normally indicate oxygen levels of 20 9 we may need to be
33. n registering this product InstallShield Press Next NALO Document Ref P0102 804 00 January 2015 Page 6 32 LC Series Software Configuration amp System Calibration User Manual 122x32 Display E8a Emulator Software V 1 00 Release 00A InstallShield Wizard Complete Please set a check sign into the Executes a Support Information Tool box for confirming your user information Y Executes a Support Information Tool Y Open a precaution file install St L cnan M rmn NNN Concer Press Finish Renesas 5upport information For user registration and technical support ok J cancel Select language then press OK Follow the on screen prompts Document Ref P0102 804 00 January 2015 Page 6 33 NAL LC Series Software Configuration amp System Calibration User Manual 122x32 Display 7 Firmware update From time to time it may be necessary to update the system firmware This can only be carried out using purpose designed PC software and the Renesas E8a programmer fitted with a specialised lead See section xx 7 1 Creating a new project Launch the PC programmer default location is typically C Program Files Renesas FDT4 01 FDT exe The following screen will be shown Welcome r Options Cancel Administration gt C Browse to another project workspace Press OK New Project Workspace Projects EDT Project Gen ka Workspace Name
34. o allow the system to be fine tuned to a particular application and these options may require changing as the system develops e g addition of a sensing channel change in alarm triggering level Before attempting to configure the system ensure 1 All input modules have the correct hardware configuration 2 The detector heads have been correctly connected to the appropriately configured input module Refer to the LC system installation and hardware configuration manual Most of the features available within the MCU system are configurable in software via the front panel display and keypad Pressing the MENU button as indicated by the display provides access to these features following correct password entry if enabled The configuration is consists of several parts 1 Controller configuration 2 Channel configuration 3 Relays 4 Inhibit 5 View 6 Engineer This following diagram shows the position of each of the menus available within the LC software Document Ref P0102 804 00 January 2015 Page 4 8 NALO LC Series Software Configuration amp System Calibration User Manual 122x32 Display LC controller menu structure Menu Controller 2 Staru up delay NEXT Fault delay NEXT NEXT Decimal point NEXT NEXT Password gt Set password oe Confirm password NEXT GO Select channel NEXT 1 2 3 or 4 Alarm levels sa Level 1 2 2 Level direction NEXT Alarm delay a Level 1 2 Set delay NEXT N
35. press Next Document Ref P0102 804 00 January 2015 Page 6 29 NALO LC Series Software Configuration amp System Calibration User Manual 122x32 Display Choice of an installation Choice of an installation Choose a folder to install When you install it in this folder please click a Next button When you install it in another folder click a Change button and please choose a folder Folder of an installation C Program Files Renesas Hew 001 Change Press Next Choice of an installation product Please choose a software product to install v E8a Emulator Software W1 00 Release 004 740 Family Compiler Package V 1 01 Release 02 Evaluation Version Y AutoUpdate Flash Develooment Toolkit Detail Please choose from the list Cit will installed one by one by this order Please push a hstall button after having chosen a software product to installt execute installation program Back Install Exit De select 740 Family then press Install Confirm Do you wish to install a new High performance Embedded Workshop The High performance Embedded Workshop you install will become active Press Yes If the following screen is shown Confirm AutoUpdate is starting Do you dose AutoUpdate Press Yes Document Ref P0102 804 00 January 2015 Page 6 30 NALO LC Series Software Configuration amp System Calibration User Manual 122x32 Display Hig
36. r will return to normal operation MENU X Document Ref P0102 804 00 January 2015 Page 5 28 NALO LC Series Software Configuration amp System Calibration User Manual 122x32 Display 6 PC programming software Install the programming software contained on the CD Execute lt Drive gt HewlnstMan exe in the CD for installation according to the instruction displayed on the screen High performance Embedded Workshop Install Manager RENESAS Eatelation _ Everywhere you imagine Multi installation Input User Information Active Detail The High performance Embedded Workshop Install Manager is the utility that guides you through steps as you ol install the integrated development environment Ab lili Embedded eS Bae you to i install two or more instances of the High performance Switch over H Embedded Workshop in a single PC Hagh performance aci p ph performance a Workshop Non active Select Installation Choice of an installation mode Please choose an installation method C Update the active High performance Embedded Y orkshop Recommend This method creates one High performance Embedded Workshop folder in your PC See at the precautions This method creates multiple High performance Embedded Workshop folders in your PC See at the precautions After selecting the installation method you want click Next Select Install a new High performance Embedded Workshop then
37. sary to measure the voltage at the device if it a long way from the control unit Connect a multimeter to the variable PSU output and select a range that will display up to 30V dc ge ee Document Ref P0102 804 00 January 2015 Page 4 19 From the System Configuration menu select CHANNEL and press GO Select the appropriate channel number and press GO Select SET VOLTAGE and press GO The following screen will now be displayed Press the INCrease or DECrease button to adjust the output to the desired level as shown on the multimeter Press the EXIT button The system Warning screen will now appear Press YES to save settings or NO to abandon changes The display will now return to the SET VOLTAGE menu Press EXIT until the display returns to the normal screen NALO LC Series Software Configuration amp System Calibration User Manual 122x32 Display 4 4 Sensor type This option allows the user to change the type of gas each channel is monitoring as a result of sensor change Any change in settings using this menu option must be followed by a calibration From the system configuration menu select CHANNEL and press GO Select the appropriate channel number and press GO From the channel options screen select SENSOR TYPE and press GO A sensor selection screen will be displayed Select the appropriate sensor type by using the PREVious and NEXT buttons then press GO The Sensor Scale screen will now be d
38. to an alarm condition If a relay is set as non latching the relay will operate when an alarm condition is encountered and the relay will return to its normal state once the condition has passed If the relay is set as latching then the relay will not return to its normal state until the alarm condition has passed AND the alarm has been accepted at the LC keypad DELAY Each relay has a parameter called DELAY associated with it This parameter refers to the number seconds that a channel must encounter an alarm signal before the system actually registers the alarm The maximum DELAY value is 10 lf DELAY 2 a channel must indicate an alarm condition for more than 2 seconds before the system will operate alarm relays This can eliminate spurious alarms 4 5 1 Level 3 alarm relays Relay 3 for Level 3 alarms don t individually exist but are combined to form 1 common level 3 relay This results in only 1 option being made available the latching function a From the System Configuration menu select Relays and press GO b Select the appropriate relay using the PREVious and NEXT buttons and press GO Notice only the LATCH option setting that will be changed when TOG is pressed c Press EXIT when the desired options are set d The system Warning screen will now appear Press YES to save settings or NO to abandon changes e The display will now return to the Relay menu Press EXIT The display will now return to the normal screen
Download Pdf Manuals
Related Search
Related Contents
UH50E - 日立工機 Références Manual de usuario para el manejo de software Softkesha versio n 2.53 Les traitements à dose unique マーチン ショーデザイナー 取扱説明書 V.4.4 Marmitek Audio Anywhere 625 userguide Snelstart handleiding Zubehör Gebrauchsanweisung 5.........14 Operating instruction 15 Copyright © All rights reserved.