1. intelligent Touch Manager iTM plus adaptor plus ADP IF intelligent Touch Manager plus ADP IF iTM plus adaptor iTM plus adaptor on which termination resistor must be enabled For details refer to the plus adaptor installation manual EM11A030 moo gt Wiring specifications Cable type CPEV or FCPEV cable Core thickness AWG 22 19 Cable length The overall cable length between the intelligent Touch Manager and the terminal iTM plus adaptor is 164 ft or less Wiring connection type Sequential connections NOTE Each air conditioner controlled via an iTM plus adaptor is also assigned a DIII address between 1 00 to 4 15 From the intelligent Touch Manager it is recognized as 2 1 00 3 1 02 or the like with the DIII NET port number prefixed Installation Manual 3P291714 2B English DCM601A71 intelligent Touch Manager 2 1 2 7 1 English Connecting power supply Connect the intelligent Touch Manager to an power supply N WARNING Be sure to perform the operation during power off conditions Do not turn the power supply on
2. 0 Q m POWER The power line connection terminals A power supply voltage of 24 VAC at 60 Hz is required Near the terminal block there is a blue resin cable mount for securing the power supply cable with the clamp DII The communication line connection terminals for DIII NET which enables communications with DAIKIN s air conditioning equipment LINE PHONE The port used when subscribing to the DAIKIN Air Conditioning Network Service System online monitoring service for air conditioning systems To use the Air Conditioning Network Service System service you need to sign a sepa rate maintenance contact RESERVE No Use RS 485 The terminals for connecting serial equipment plus ADP IF The terminals for connecting one or more iTM plus adaptors when the intelligent Touch Manager is used to control more air conditioning devices Di 1 4 COM The terminals for stopping air conditioners according to the external signal in an emergency for connecting a power meter to calculate the electricity usage of individual air conditioners or for other operations LAN The port for connecting the intelligent Touch Manager to an Ethernet network Installation Manual 3P291714 2B English DCM601A71 intelligent To
3. I I 1 1 I I I 1 I I 1 1 I I 1 I I I 1 I I I 1 I I 1 1 1 I I 1 I I 1 1 I I I 1 I I 1 I I 1 1 I I 1 1 I I E ls a asl er Outdoor unit OUT OUT communication terminal IN OUT communication terminal Indoor unit A maximum of 16 indoor units can be connected per remote controller group mo ouw gt A maximum of 64 remote controller groups 128 indoor units can be connected When the power proportional distributions is applied the maximum number of indoor units is 64 Installation Manual 3P291714 2B 15 DCM601A71 intelligent Touch Manager 2 2 2 2 2 3 NOTE What s a remote controller group A single remote controller can simultaneously control a maximum of 16 indoor units This capability is referred to as group control A remote controller group is a group of indoor units controlled under the same remote controller Schematic diagram of remote controller group A e Fi F2 NP 1 2 NP F1 F2 Be gt X lt Y A Max 16 Indoor units Wiring specifications Cable type 2 core vinyl insulated vinyl sheathed cable vinyl cabtyre cable or 2 core shielded cable Core thickness AWG 18 16 e Terminal treatment Use a round crimp ty
4. Step 3 Group Address Group Address Group Group Address Unit Setting Y 4 Press the Menu OK button to release the current address setting The mode indication changes from Set to Release You are now ready to change the DIII NET address Step 4 Group Address Group Gr Addr Set 1 00 Release 38 Installation Manual 3P291714 2B English DCM601A71 intelligent Touch Manager 4 7 4 English 5 Using the Up Down buttons select the address you want to set lt Step 5 gt Group Address Group Gr Addr Release 1 00 Change Y 6 Press the Menu OK button The indication changes from Release to Set and the DIII NET address is set Step 6 gt Group Address Group Gr Addr Set 1 03 Release 7 Press the Cancel button three times You are now brought back to the screen shown in Step 7 2 Step 7 1 Group Address Group Gr Addr Set 1 03 Release Step 7 27 hu 5 35P Room Setto 82r 86F Cool w 6 qv aul Setting an unique address to each unit when Power Proportional Dis tribution option is used When power distribution is enabled you need to set a unique address for each unit For how to set an address refer to the Commissioning Manual Supplementary Volume Powe
5. Do not clamp the LAN cable with high current cables NOTE For how to connect the intelligent Touch Manager to a PC network contact your net work administrator Installation Manual 3P291714 2B 17 DCM601A71 intelligent Touch Manager 2 3 1 Terminal location and schematic connection diagram Using a LAN cable connect the LAN port to the network hub lt LAN connection schematic diagram gt A Rear face of intelligent Touch Manager B LAN C Hub D PC 2 3 2 Wiring specifications Applicable cable standard 100Base TX or 10Base T Connector standard RJ 45 NOTE When you connect the intelligent Touch Man ager to the LAN temporarily during installation or maintenance use the SERVICE LAN port located on the front face The SERVICE LAN port is enabled by chang ing the position of the LAN SW switch beside the SERVICE LAN to the FRONT position You cannot close the cover when the switch set to FRONT To close the cover select BACK 18 Installation Manual 3P291714 2B SERVICE LAN socket and LAN SW swi
6. Time DST Setup 04 21 2013 09 17PM Date Time 04 23 2013 09 15 04PM Daylight Saving Time Settings Activation Enable Start Date yar w End Date foa On the Time DST Setup screen set up the date time and the daylight saving time schedule Enable or disable the daylight saving time function If enabled select the start time and the end time Touch OK The A C Auto Register screen appears Confirming air conditioner auto registration results On the A C Auto Register screen the message Below connected A C units are found Do you want to register into Management Points Reboot after registering appears 1 Check that the number of all air conditioners that are set in section 4 7 Setting DIII NET address for each air conditioner is correctly displayed If you see any problem touch the Refresh button to reload the up to data information or review the DIII address settings When the confirmation dialog appears touch Yes The intelligent Touch Manager restarts and Main screen appears The intelligent Touch Manager setup has now been completed NOTE When iTM plus adaptor is connected power on the iTM plus adaptor in advance Installation Manual 3P291714 2B English DCM601A71 intelligent Touch Manager 4 7 4 7 1 English Setting DIII NET address for each air conditioner The DIII NET system has the c
7. 10 1 3 22 FOPIN C eed 11 1 3 3 SIDS TACC c 12 1 34 Wiring of Cables xiu bodie i atate ates decr bed ertet ceu decus er SRA YA 12 1 44 Determining Installation place endrerit eet te atte te Era rend 13 1 4 1 Installation place and mounting direction 13 1 4 2 Environmental Conditions 2 ctc rea tet edet endete deu recur eurn 13 1 4 3 Required 0000 nnn nnne nns tenen nnn nente 13 2 Electric Wiring 14 21 Removing wiring cover from rear 14 2 2 Connecting DIII NET compatible air conditioning 14 2 2 1 Terminal location and schematic connection diagram 15 2 2 2 Wiring specifiCations etse etae eio tesi 16 2 2 3 Precautions for using multiple centralized 16 2 3 Connecting a LAN cable mnssssssssssrssasrrrsrrsssrssserssnrrssrranersn rna nnne enne nnns RAKA RR KR RAKA RAKA innen 17 2 3 1 Terminal location and schematic connection 18 2 9 2 Miririg SpeclfICallOris rere tais Sete 18 2 4 Connecting
8. 3 Press the SCHEDULE button to make the GROUP indicator blink You are now ready to change the DIII NET address Step 3 7 GROUP mn a PIAS OO Installation Manual 3P291714 2B English DCM601A71 intelligent Touch Manager 4 Using the Programming time buttons select the address you want to set lt Step 4 gt LILI SETTING E om CH VI GRO pEr an 5 Press the SCHEDULE button to make the GROUP indicator stay lit The DIII NET address has been set lt Step 5 gt Vir1 LILI SETTING GROUP 7 6 Press the Inspection Test Operation button You are now brought back to the screen shown in Step 6 2 Step 6 1 riui GROUP 4 0 LILI SETTING lt Step 6 2 gt 2 English Installation Manual 3P291714 2
9. address for each air 2 24 00 10 00 35 4 7 1 Names of buttons and display 35 4 7 2 Setting address with wired remote controller 36 4 7 3 Setting address with navigation remote controller 0 38 4 7 4 Setting an unique address to each unit when Power Proportional Distribution option is used 39 Quick Operation GU IGG uci tein pue kp talit eau aa aaa SENA AEREE 40 5 1 Viewing target area and management point information in list 40 5 2 Displaying areas and management points enne 40 5 3 Starting stopping an area or management point 2 41 Installation Manual 3P291714 2B English DCM601A71 intelligent Touch Manager 1 1 English Before Installation Before you start installing the intelligent Touch Manager perform the following preparatory checks Check that the intelligent Touch Manager comes with all accessories Confirm where the terminals and switches of the intelligent Touch Manager are located Check that an appropriate space for installing the intelligent Touch Manager is available Checking that all accessories are included Based on the following accessory list check that all accessories for the intelligent Touch Manager are included If there is any missing or defective part contact your DAIKIN dealer where you purc
10. This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme la norme NMB 003 du Canada Safety Considerations English All phases of the field installation including but not limited to electrical piping safety etc must be in accordance with manufacturer s instructions and must comply with national state provincial and local codes Read these SAFETY CONSIDERATIONS carefully before installing the controller After completing the installation ensure that the controller operates properly during the startup operation Train the customer to operate and maintain the controller Inform customers that they should store this Installation Manual with the User s Manual for future reference Always use a licensed installer or contractor to install this product Improper installation can result in electrical shock fire or explosion Meanings of WARNING CAUTION and NOTE Symbols A WARNING Indicates a potentially hazardous situation which if not avoided could result in death or serious injury Indicates a potentially hazardous situation which if not CAUTION avoided may result in minor or moderate injury It may also be used to alert against unsafe practices NOTE Indicates situations that may result in equipment or prop erty damage accidents only A WARNING Only qualified personnel must carry out the installation work Consult your Daikin dealer
11. Be sure to perform the operation during power off conditions Not doing so may cause an electric shock The maximum length of adhered wiring of high current electrical line of power wires and weak current line of communication wires must be kept to 65 ft or less Installation Manual 3P291714 2B English DCM601A71 intelligent Touch Manager 2 2 1 English Terminal location and schematic connection diagram To connect the DIII NET communication line use F1 and F2 terminals that are located on the rear face and indicated with DIII mark These 2 terminals have no polarity An exam ple of connecting more than two air conditioning devices is shown in the following concep tual connection diagram N CAUTION Make sure that the wires you are connecting to the F1 and F2 terminals are not power wires Inadvertently connecting power wires to these terminals results in a failure of the air conditioner or intelligent Touch Manager Conceptual connection diagram with air conditioning equipment e 0
12. Frame bracket 11 3 32 Xr TT 4 d a e e 5 9 2 e T A 9 cb o I J r o v 9 32 gt ry 32 i Thickness 1 16 in Angle bracket Pad 15 32 A A 97 D 94 5 288 o olo v wv 25 32 St 1 23 32 4 Thickness 1 16 in English Installation Manual 3P291714 2B DCM601A71 intelligent Touch Manager 1 3 1 3 1 Understanding where terminals and switches are located Understand the arrangement of terminals and the location of openings on the unit and plan how to route the cable and in which order to connect its wires to facilitate the instal lation procedure For connection details including the cable type and terminal size refer to 2 Electric Wiring Rear face Most terminals are located on the rear face of the intelligent Touch Manager However they are covered with a terminal cover for safety reasons Remove 2 screws to detach the cover and you can see various types of ports terminals lt Rear face of intelligent Touch Manager gt TO ale e6
13. I O RAKA RAKA RAK KRK RAR nnne 19 2 4 1 Terminal location and schematic connection 19 2 4 2 Wiririg SpecifICalloris do ciae Ee bute eda iiie t nei exea dee Qua ho rcu esae ac 19 2 4 9 Address Setup uertit 2 20 2 5 Connecting an emergency stop input device or power 20 2 5 1 Terminal location and schematic connection 20 2 5 2 Wiring SpecifICaliOris ui etiem 21 2 66 Connecting iTM plus Adaptors 2 4 0000000 0 nnns 21 2 6 1 Terminal location and schematic connection 22 2 6 2 MWiririg Specificatioris srne 5 o bleue Eaux Edere 22 2 7 Connecting power Supply 5 tres ba da etna 23 2 7 1 Terminal location and schematic connection 23 2 7 2 Wiring eee x a Reid n oen See ah 24 3 Secureinstallation of intelligent Touch Manager 25 3 17 Wal MOUNTING 25 8 1 1 Parts to be used eek ea
14. Vertical only Environmental conditions Check that the installation environment meets the following conditions The ambient temperature 32 to 104 F The ambient humidity 8596 RH or less without condensation The electromagnetic wave does not affect the operation of the intelligent Touch Man ager Required space The figure shown below indicates the space required for installation The following condi tions must be met Make sure that there is a minimum clearance of 1 3 16 in from the top edge 3 15 16 in from the left side edge 1 3 16 in from the right side edge and 2 3 8 in from the bottom edge of the unit Installation space required for intelligent Touch Manager 22 3 15 16 3 15 16 1 3 16 4 0 9 9 16 11 13732 2 3 8 Se ZZ 77 Wall Installation Manual 3 291714 2 13 DCM601A71 intelligent Touch Manager Required proce dures Equipment spe cific procedures 2 1 2 2 Electric Wiring This chapter describes the procedure for connecting the intelligent Touch Manager with DAIKIN air conditioning devices and other equipment In addition to air conditioners the intelligent Touch Manager can monitor and control a wide range of equipment However the required connection procedures vary de
15. be exposed to the power line connection terminals when opening the control Touching electrical junctions by hand may result in an electric shock Attach the 31 4 1 4 2 32 Basic setup of intelligent Touch Manager After checking that all connections are completed start the intelligent Touch Manager basic setup The basic setup refers to the preparative settings for monitoring and control ling the air conditioning system using the intelligent Touch Manager Make each setting by following the guidance displayed on the screen after you turn on the power supply of the intelligent Touch Manager The setting assignment made through this procedure may be changed at a later time Setting backup battery to ON To retain the settings even in the event of a power outage the intelligent Touch Manager has a built in battery This battery is disabled by default So first you need to change the battery setting to ON lt BACKUP switch gt 1 Open the front slide cover Take out screws using a Phillips screwdriver to remove the front switch cover 2 Turn ON the BACKUP switch and attach the front on FERRE switch cover back to its original position If the sexo oc masten power supply is left off for a long period of time six months or more turn OFF the BACKUP switch OFF MASTER Turning on power supply for intelligent Touch Manager and air conditioners Turn on the power supply for the intelli
16. earth leakage breaker installation and earth wire connection After installing an earth leakage breaker be sure to connect only the intelligent Touch Manager to it To prevent accidents due to wire breakage or disconnection secure the power supply cables to the blue resin cable mount with cable ties Be sure to connect the earth wire Do not connect the earth wire to gas or water pipes lighting rod or telephone earth wire Replace the unit when the unit cannot be turned on due to the blowing of the electrical fuse Installation Manual 3P291714 2B English DCM601A71 intelligent Touch Manager 3 Secure installation of intelligent Touch Manager There are the following three ways to install the intelligent Touch Manager Wall mounting Fix the intelligent Touch Manager to the metal plate which is attached to the wall e Flush wall mounting Embed the back of the intelligent Touch Manager into the wall using the frame bracket and angle brackets Direct mounting to control enclosure Fix the intelligent Touch Manager directly to the control enclosure using screws only with no brackets Ways of installation Wall mounting Flush wall mounting Direct mounting to control enclosure 3 1 Wall mounting 3 1 1 Parts to be used To wall mount the intelligent Touch Manager use the following accessory mounting parts Wall mounting metal plate 1 pc Round head wo
17. point is displayed B Touch the Down button to go to the area being selected and view the areas and management points in it C Touch the Up button to go to the area one level above the current area 40 Installation Manual 3P291714 2B English DCM601A71 intelligent Touch Manager 5 3 Starting stopping an area or management point ves 25 eaves Bia 5557 nna zal r B 4 lt B R P EB T Setpoint 4 4p 4 a Areas Areat Area Area Area Areas H 2 ET 21 01 11 05 11 06 1 1 07 11 08 210 sss Menu Tue 04 23 Moni 04 23 Let 05 13PM List 05 16PN A Select the area or management point you want to start or stop B Select Start or Stop in the On Off buttons When operation is started the icon color changes to green or red depending on the system setting When operation is stopped the color changes to grey English Installation Manual 3P291714 2B 41 DCM601A71 intelligent Touch Manager 3P291714 2B EM11A018A 6306
18. B DCM601A71 intelligent Touch Manager 4 7 3 Setting address with navigation remote controller The operation procedure of the navigation remote controller is as follows NOTE You cannot perform the following procedure when the display backlight is off In this case press any key to turn on the backlight before starting the procedure 1 Press and hold the Cancel button for 4 seconds or more The Service setting menu is displayed lt Step 1 gt thu 5 31P Room Set to Vv e alll 82 7e Cool 2 Using the Up Down buttons select Group Address and press the Menu OK button The Group Address menu is displayed lt Step 2 gt Service Settings 2 3 Group Address Indoor unit AirNet Address Error History Indoor Unit Status Outdoor Unit Status Forced Fan ON a Setting NOTE The Group Address menu is not displayed when the intelligent Touch Manager is not powered on Power on the intelligent Touch Manager and wait for a while before trying to operate the remote controller The Group Address menu is not displayed also when the intelligent Touch Manager is not communicating with the indoor units normally Check that the cables are connected correctly 3 Using the Up Down buttons select Group Address Group and press the Menu OK button The current address setting is displayed
19. Comma Semicolon con Color 1 LOCALE Set the following items on the screen Date Select the date display format Time Select the time display format 24 hour or 12 hour clock Celsius Fahrenheit Select the temperature display unit Celsius or Fahrenheit Decimal point CSV separate Select the marks used as the decimal point and CSV separator For details refer to the User s Manual EM11A017 Icon Color Select the icon color 2 When setup is done touch OK The Time Zone Settings screen appears 4 4 Setting time zone Set up the local standard time zone you want to use for the system clock Time Zone Settings screen Time Zone Settings Time Zone IGMT Greenwich Mean Time Dublin Casablanca IGMT 01 00 Paris Roma Warsaw Sarajevo ISMT 02 00 Athena Israel Cairo Bucharest GMT 03 00 Nairobi Baghdad Moscow IGMT 03 30 Teheran ISMT 04 00 Abu Dhabi Muscat Baku Tbilisi IGMT 04 30 Kabul IGMT 05 00 slamabad Karachi Tashkent IGMT 05 30 Munbai New Delhi 1 On the Time Zone Settings screen select the time zone of desired region from the list box 2 Touch OK The Time DST Setup screen appears English Installation Manual 3P291714 2B 33 DCM601A71 intelligent Touch Manager 4 5 4 6 34 Setting current time and daylight saving time Adjust the clock and set up the daylight saving time schedule Time DST Setup screen
20. DAIKIN Installation Manual intelligent Touch Manager Model DCM601A71 3P291714 2B To the User in USA Part 15 of FCC Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equip ment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communica tions However there is no guarantee that interference will not occur in a particular installa tion If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help FCC CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment To the User in CANADA Canadian ICES 003
21. ager 2 3 English DIll MASTER To change the setting of the intelligent Touch Man ager to SLAVE turn the DIII MASTER switch located under the front slide cover Placing the DIII MASTER switch in the upper position labeled as SLAVE changes it to a SLAVE SLAVE H DII MASTER OFF MASTER MASTER When installing multiple centralized controllers set only the highest priority controller to MASTER and all other controllers to SLAVE according to the following order of priority 1 Interface for use in BACnet High 2 Interface for use in LONWORKS 3 intelligent Touch Manager Main iTM plus adaptor Main 4 Central Remote Controller Main 5 intelligent Touch Manager Sub iTM plus adaptor Sub 6 Central Remote Controller Sub Low 7 ON OFF Controller Main 8 ON OFF Controller Sub Priority Centralized controllers that cannot be connected to the same network as the intel ligent Touch Manager CALCULATE UNIT intelligent Processing Unit Parallel Interface intelligent Touch Controller DIII NET Plus Adapter Residential Central Remote Controller Schedule Timer Wiring Adaptor for Electrical Appendices 1 KRP2 Connecting a LAN cable By connecting the intelligent Touch Manager with a PC via Ethernet you can remotely perform operations such as operation setup and maintenance of air conditioning system N WARNING
22. con nection is established normally between the intelligent Touch Manager and the equip ment connected to the LAN port It is lit when there is no error DIII MONITOR LED Yellow This LED blinks when data is sent or received via DIII NET communication line MONITOR key and LED Orange Green Each time you press this key the monitor display turns on off The color of the LED also changes simultaneously Off The monitor is powered off On Orange The monitor display is off On Green The monitor display is on RESET The switch for restarting the intelligent Touch Manager Installation Manual 3P291714 2B 11 DCM601A71 intelligent Touch Manager 1 3 3 1 3 4 Side face On the left side of the intelligent Touch Manager there is a USB port The USB port is used for making settings performing maintenance or other operations after the installation of the intelligent Touch Manager is completed Also on this side a label is attached on which the information such as product name weight power supply and serial number are printed Side face of intelligent Touch Manager p v1 Open this cover to connect the memory to the USB port This port can be turned 90 degrees to the front direction You can connect to this port from the front direction if there is not enough space on the side Wiring of cables To flush mount the intelligent Touch Manager to the wall you need to route in advanc
23. e 10 1 8 1 8 5 32 10 23 32 in A Control enclosure face plate B Control enclosure bottom board C intelligent Touch Manager D 31 32 in min E Opening Installation procedure 1 Remove the front panel of the intelligent Touch Manager referring to Removing front panel in section 3 2 3 Installation procedure This frame is snapped into the edge of the monitor display You can remove it by hand as it is not screwed After removing the front panel the four holes two holes on each right left side appears around the monitor screen 2 Insert the intelligent Touch Manager into the opening of the control enclosure and install it to the control enclosure using the pan head screws 3 Attach the front panel of the intelligent Touch Manager back to its original position Installation Manual 3P291714 2B English DCM601A71 intelligent Touch Manager English lt Installing intelligent Touch Manager body to control enclosure gt IIII III II A Pan head screw B Nut N CAUTION enclosure door terminal cover to the rear face for your safety A A Terminal cover B Control enclosure C intelligent Touch Manager Installation Manual 3P291714 2B DCM601A71 intelligent Touch Manager If the intelligent Touch Manager is directly mounted to the control enclosure you will
24. e the cables through the cable hole of the frame bracket The following pictorial wiring diagram example shows the state after connections to the intelligent Touch Manager rear face are completed Pictorial cable wiring diagram example R V nh n m ds A Push mount tie B Clamp C Toconduit tube Be sure to fix all cables using the supplied push mount ties Fix the power supply cable to the blue resin cable mount using the white clamp then tie the cable and other cables with the black push mount tie as shown in the cable wiring diagram example When using the black push mount tie pass its tale through its hole to tie the cables Installation Manual 3P291714 2B English DCM601A71 intelligent Touch Manager 1 4 1 4 1 1 4 2 1 4 3 Required installa tion space English Determining installation place Be sure to install the intelligent Touch Manager in a place that meets the conditions described in 1 4 1 to 1 4 3 Installation place and mounting direction Below are the description of the installation place and mounting direction Be sure to confirm Installation place Indoor free from dust and water splashes For details refer to CAUTION in the section of Safety Considerations Mounting direction
25. e the front panel from the front face of the intelligent Touch Manager The front panel is originally attached to the monitor screen 28 Installation Manual 3P291714 2B English DCM601A71 intelligent Touch Manager lt Removing front panel gt A Front panel B Main body 3 Insert the intelligent Touch Manager into the frame bracket attached to the wall and fix the intelligent Touch Manager to the frame bracket using four screw holes around the monitor screen and the pan head screws Installing intelligent Touch Manager body II NN Ss A Pan head screw 4 Attach the front panel of the intelligent Touch Manager back to its original position English Installation Manual 3P291714 2B 29 DCM601A71 intelligent Touch Manager 3 3 3 3 1 3 3 2 3 3 3 30 Mounting to control enclosure Parts to be used To mount the intelligent Touch Manager directly to the control enclosure use the following accessory mounting parts Pan head screw M4x40 with spring washer and plain washer 4 pcs Nut 4 4 pcs Wall opening dimensions Use the following dimensional drawing to provide a sufficient opening NOTE The supplied paper template helps you mark the dimensions of the required wall opening Use the supplied paper template Direct mounting to control enclosure Wall opening dimensions for direct mounting to control enclosur
26. en using a shielded cable be sure to connect the cable to the G ground terminal Installation Manual 3P291714 2B 19 DCM601A71 intelligent Touch Manager 2 4 3 2 5 2 5 1 20 Address setup lt Bus coupler gt The bus coupler located at the left end of nodes has rotary switches for setting the addresses Set a unique address for each node For details refer to the Commissioning Manual Supplementary Volume External Management Points 11 026 gt 2 2 2 2 2 2 2 2 2 Connecting emergency stop input device power meter The intelligent Touch Manager can perform operations such as an emergency stop of air conditioners according to the external signal input device and an electricity usage calcu lation for each air conditioner for power proportional distribution according to the pulse inputs from a power meter N WARNING Be sure to perform the operation during power off conditions Not doing so may cause an electric shock Do not clamp high current cables together with low current cables Terminal location and schematic connection diagram Connect the contact input signal wire or pulse signal wire to Di1 Di2 Di3 Di4 or COM terminal on the orange connector on the rear face Each of these terminals has different function Di1 Emergency stop input Di2 Di3 Di4 Pulse input contact signal input COM Common However the function set
27. gent Touch Manager and devices that are con nected to the intelligent Touch Manager 1 First turn on the power supply for the air conditioners and then for intelligent Touch Manager The Title screen appears and after a while the message Ready to set up A C centralized address appears Set the DIII NET addresses using the remote controller of the air conditioner For details refer to section 4 7 Setting DIII NET address for each air conditioner 2 Touch Close The Locale Settings screen appears N CAUTION Before turning on the power supply double check that all installations and con nections are completed correctly NOTE The message Turn ON Battery Backup switch may be displayed instead of the Locale Setting screen This message is displayed if you do not turn ON the data backup battery switch in the step 4 1 If the message is displayed make the setting according to sec tion 4 1 Setting backup battery to ON When done touch the OK button shown with the message on the screen Then the Locale setup screen appears Installation Manual 3P291714 2B English DCM601A71 intelligent Touch Manager 4 3 Setting up locale Set the display type of date time unit of temperature decimal point type etc Locale Settings screen Date Display MM DD YYY Y ly Time Display C 24n 9 Celsius Fahrenheit r Decimal Point CSV Separation bot
28. hased the product Accessories included with intelligent Touch Manager D We ge GO A a 1 intelligent Touch Manager body 1 pc B Wall mounting parts 6 1 Round head wood screw 4 1x25 4 pcs b 2 P tight screw 3 8 1 pc b 3 Wall mounting metal plate 1 pc C Flush wall mounting parts c 1 Flat head screw M4x40 4 pcs c 2 Pan head screw M4x14 with spring washer and plain washer 4 pcs c 3 Frame bracket 1 pc c 4 Angle bracket 2 pcs D Control enclosure securing parts d 1 Pan head screw 4 40 with spring washer and plain washer 4 pcs d 2 Nut 4 4 pcs E 1 Clamp 1 e 2 Push mount tie 3 pcs 1 Installation manual This manual 1 pc f 2 Paper template 2 pcs Installation Manual 3P291714 2B 7 DCM601A71 intelligent Touch Manager 1 2 Understanding external dimensions intelligent Touch Manager body 10 3 32 10 23 32 N Q e bs D D 1 Y 3 16 T 36 1 N eo e T 3 16 3 16 e e 11 13 32 te in Wall mounting metal plate Thickness 1 32 in 8 Installation Manual 3P291714 2B English DCM601A71 intelligent Touch Manager
29. n ternera acier e dnb a Yu ORE Y EHE Y ne EE RUNE 25 3 1 2 IInistallatiori a eu cte toe o vue ta xvm ove 26 English Installation Manual 3P291714 2B DCM601A71 intelligent Touch Manager 3 2 FIUSN toon tee mee RAA SNS 27 c aliii 27 3 2 2 Wall opening 27 3 2 3 Installation 28 3 3 Mounting to control 30 2 31 Em 30 3 3 2 Wall opening 30 323 9 Installation procedure 30 Basic setup of intelligent Touch Manager 32 4 1 Setting backup battery to ON 32 4 2 Turning on power supply for intelligent Touch Manager and air conditioners 32 4 3 Setting up locale 2 33 4 4 Setting time zone occ eee kar hink nr h r SER entres rennen Krona R SA 33 4 5 Setting current time and daylight saving time inmnsmssesrssersesrrssrerssrrssrrrrsrrrsnr rr senares arr rar RR 34 4 6 Confirming air conditioner auto registration results 2 34 47 Setting
30. ndoor groups you can control using a single intelligent Touch Manager is limited to 64 By using iTM plus adaptors you can add 64 indoor unit groups per iTM plus adaptor Moreover considering that the intelligent Touch Manager can be connected with a maximum of seven iTM plus adaptors you can control a total of 512 groups of indoor units at a maximum using a single intelligent Touch Manager E AN WARNING Be sure to perform the operation during power off conditions Not doing so may cause an electric shock Do not clamp high current cables together with low current cables English Installation Manual 3P291714 2B 21 DCM601A71 intelligent Touch Manager 2 6 1 2 6 2 22 Terminal location and schematic connection diagram Connect the iTM plus adaptor to the plus ADP IF terminal located on the rear face Con nect the intelligent Touch Manager to the plus ADP IF terminal As the terminals have polarity be sure to connect the positive wire to the terminal and the negative wire to the terminal without fail Connect the intelligent Touch Manager to the termination of the RS 485 wiring Terminal location and schematic connection diagram ala
31. od screw 4 1 25 4 pcs P tight screw 3x8 1 pc Check that there are all accessories listed in section 1 1 see the accessories included with intelligent Touch Manager B English Installation Manual 3P291714 2B 25 DCM601A71 intelligent Touch Manager 26 Installation procedure N CAUTION The wall mounting metal plate has a number of holes for attaching the round head wood screws Though you can use any of these holes to fix the plate we recommend you to use ones closer to the edge in order to prevent wobbling Secure the round head wood screws at four points Wall mounting installation R gt Ess NOTE How to use the P tight screw Screw in from the bottom of the intelligent Touch Manager Remove the rear cover before starting installation Wall P tight screw Round head wood screw Wall mounting metal plate moo gt intelligent Touch Manager Installation Manual 3P291714 2B English DCM601A71 intelligent Touch Manager 3 2 3 2 1 3 2 2 English Flush wall mounting Parts to be used To flush mount the intelligent Touch Manager to the wall use the following accessory mounting parts Frame bracket 1 pc Angle bracket 2 pcs Flat head screw M4x40 4 pcs Pan head screw M4x14 with spring washer and plain washer 4 pcs Check that there are all accessories listed in section 1 1 see the accessories included
32. ontrol address used to identify each air conditioner group This is called DIII NET address You must set the DIII NET address manually using the remote controller of air conditioner There are several types of the remote controller and the setting method differs depending on the controller type This section describes com monly used two types of remote controllers wired and navigation remote controllers as examples NOTE For how to set the address for the Ventilator Heat Reclaim Ventilator or different adapt ers such as a universal adapter refer to the manuals supplied with those devices Names of buttons and display areas The followings are the names of buttons and display areas of the wired remote controller Wired Remote Controller gt Address display area Parameter number display area Programming time buttons Temperature setting buttons SCHEDULE button Inspection Test operation button mo ouv The followings are the names of buttons and display area of the navigation remote control ler lt Navigation Remote controller gt Liquid crystal display with backlight A B Up button A C button D Right button P E Cancel button F Down button w Installation Manual 3P291714 2B 35 DCM601A71 intelligent Touch Manager 4 7 2 36 Setting address with wired
33. pe terminal M3 5 with insulating sleeve N CAUTION Do not use multicore cables with three or more cores When using a shielded cable connect only one end of the cable to the ground The maximum wiring length is 3280 ft and total wiring length is 6561 ft or less When using a shielded wire the total wiring length is limited to 4921 ft or less Precautions for using multiple centralized controllers The centralized controller refers to the equipment e g the intelligent Touch Manager that controls multiple air conditioners Besides the intelligent Touch Manager the DAIKIN s product portfolio includes a wide range of centralized controllers suitable for different applications or building sizes which can be used in combination to construct an optimal air conditioning control system If multiple centralized controllers are connected on the DIII NET network you must set MASTER and SLAVE relationship for those controllers Assign only one of those controllers to MASTER and other controllers to SLAVE The intelligent Touch Manager is set to MASTER by default Change the setting to SLAVE in any of the following cases Where Interface for use in BACnet is installed in parallel Where Interface for use in LONWORKS is installed in parallel e If there is another intelligent Touch Manager or iTM plus adaptor which is assigned to MASTER Installation Manual 3P291714 2B English DCM601A71 intelligent Touch Man
34. pending on the equipment to be connected Do not connect more than two wires to the same terminal 2 2 Connecting DIII NET compatible air conditioning equipment 2 7 Connecting power supply 2 3 Connecting a LAN cable 2 4 Connecting I O module 2 5 Connecting an emergency stop input device or power meter 2 6 Connecting iTM plus adaptors N WARNING Do not turn on the power supply before all wire connections are completed When there is an earth leakage breaker or a local switch installed on the circuit make sure that the circuit is securely interrupted Otherwise an electric shock may result After the wiring is completed double check that all wires are connected cor rectly before turning on the power supply All field supplied parts and materials electric works must conform to local codes All wiring must be performed by an authorized electrician Removing wiring cover from rear face Removing wiring cover Remove the wiring cover from the rear face Take out two screws using a Phillips screwdriver to remove the wiring cover Connecting DIII NET compatible air conditioning equipment DIII NET is the DAIKIN s original communication method used between air conditioners Using DIII NET you can centrally control multiple DAIKIN DIII NET compatible air condi tioning devices by connecting them to your intelligent Touch Manager N WARNING
35. r Proportional Distribution EM11A027 Installation Manual 3P291714 2B 39 DCM601A71 intelligent Touch Manager 5 Quick Operation Guide This chapter describes how to start stop the areas and management points registered with the intelligent Touch Manager and display their information quickly For detailed oper ation procedures refer to the User s Manual 11 017 5 1 Viewing target area and management point information in list format 225 25 473 pp 4 Em 4p dp dp dp 4 BH ZS eg cc NH c dd 08 TE wes ZS um gt d 2 sen 14 D a Cool ud A Touch the List button B The screen changes to the list view where selecting Indoor in the Type combo box causes the name operation mode setpoint and fan speed of all areas and indoor units to be listed C Touch the Icon button to return the Icon view screen 5 2 Displaying areas and management points OAS Enni grae G Ba gt B pp dp 4 Down ap Dao B Menu Tue 04 23 DEN Let 05 09PM List A level of the current area and management
36. regarding relocation and reinstallation of the con troller Improper installation work may result in electric shocks or fire Install the controller in accordance with the instructions in the installation man ual Improper installation may cause electrical shocks or fire Use only specified accessories and parts for installation work Failure to use specified parts may result in electric shocks fire or the unit falling Do not disassemble reconstruct or repair Electric shock or fire may occur Make sure that all wiring is secured that specified wires are used and that no external forces act on the terminal connections or wires Improper connections or installation may result in fire Before touching electrical parts turn off the unit Installation Manual 3P291714 2B 3 DCM601A71 intelligent Touch Manager N CAUTION Keep water out of the controller To avoid electric shock due to entry of water or insects fill the wiring through hole with putty Do not wash the controller with water as it may result in electrical shocks or fire Do not touch the controller buttons with wet fingers Touching the buttons with wet fingers can cause an electric shock Do not install the controller in the following locations a Where a mineral oil mist or oil spray or vapor is produced for example in a kitchen Plastic parts may deteriorate and fall off b Where corrosive gas such as
37. remote controller The operation procedure of the wired remote controller is as follows NOTE After power on the controller shows the symbol SZ for about 1 minute after displaying all information on its display During this period it may not accept your operation If so try operating the remote controller again after 28 disappears 1 Press and hold the Inspection Test Operation button for 4 seconds or more Step 1 ME 2 SETTING appears in the center of remote controller display Using the Temperature Setting buttons change the value shown in the parameter num ber display area to 00 In the address display area the current address setting is displayed This area will show if no address is set Step 2 gt LILI GROUP ru SETTING NOTE The parameter number cannot be changed to 422 when the intelligent Touch Manager is not powered on Power on the intelligent Touch Manager and wait for a while before trying to operate the by remote controller You cannot change the parameter number to uu also when the intel ligent Touch Manager is not communicating with the indoor units normally Check that the cables are connected correctly
38. sulfurous acid gas is produced c Near machinery emitting electromagnetic waves Electromagnetic waves may disturb the operation of the control system and cause the unit to malfunction d Where flammable gas may leak where there is carbon fiber or ignitable dust suspensions in the air or where volatile flammables such as thinner or gaso line are handled Operating the unit in such conditions can cause a fire e High temperature area or directly flamed point Heating and or fire can occur f Moist area where there is exposure to water If water enters the inside of the controller it may cause electric shock and electrical components may fail Install the control wires for the controller at least 3 5 feet 1 meter away from televisions or radios to prevent image interference or noise Depending on the radio waves a distance of 3 5 feet 1 meter may not be sufficient to eliminate the noise Installation Manual 3P291714 2B English DCM601A71 intelligent Touch Manager Contents 1 Before Met 7 1 14 Checking that all accessories 7 1 2 Understanding external dIMENSIONS eene nnne nnnm 8 1 8 Understanding where terminals and switches are located 10 1 3 1 Real TAC
39. tch A B E LAN SW FRONT BACK m SERVICE LAN o gt LAN SW DCM601A71 intelligent Touch Manager SERVICE LAN English 2 4 2 4 1 2 4 2 English Connecting I O module In combination with the I O module the intelligent Touch Manager can monitor and control a maximum of 960 contacts of non DAIKIN peripheral devices such as lighting equipment and security systems Connect the intelligent Touch Manager to the termination of the RS 485 wiring N WARNING Be sure to perform the operation during power off conditions Not doing so may cause an electric shock Do not clamp the cables with high current lines such as a power cable Terminal location and schematic connection diagram Schematic drawing of I O module connection RS 485 M SES Wattmeter S Lighting The number of contacts per node is up to 120 The maximum Fan number of nodes is 30 Connect to the RS 485 terminals located on the rear face As the terminals have polarity be sure to connect the positive core wire to the positive terminal and the negative core wire to the negative terminal respectively Wiring specifications Cable type CPEV or FCPEV cable shielded type also acceptable Cable length 1640 ft or less Core thickness AWG 22 19 N CAUTION Wh
40. tings for these terminals can be changed later For how to change the function settings refer to the Commissioning Manual EM11A022 Schematic drawing of Di connec tion r NOTE The COM terminals are all connected internally So you can use either of them However you can connect up to two wires simultaneously to each COM terminal When using an open col lector type output connect the COM terminal to the negative side Installation Manual 3P291714 2B English DCM601A71 intelligent Touch Manager 2 5 2 Wiring specifications Cable type CPEV cable Core thickness AWG 22 19 Cable length 656 ft or less Pulse width A Pulse width 20 to 400 ms B Pulse interval 100 ms or more N CAUTION The contact connected to the contact input terminal must be capable of han dling 10 mA at 16 VDC If an instantaneous contact is used for triggering an emergency stop use one that has an energization time of 200 ms or more NOTE Once the emergency stop input signal is turned on all air conditioners stop and do not restart until the emergency stop input is cleared When the manual reset is specified for the resetting method you need to clear the emergency stop using the intelligent Touch Manager 2 6 Connecting iTM plus adaptors If you have many air conditioners use iTM plus adaptors to connect them It is a fact that the number of i
41. uch Manager 1 3 2 English Front panel Located below the monitor display on the front panel are four LEDs that indicate the oper ating status of the intelligent Touch Manager Sliding the front slide cover down and then removing a screwed cover reveals terminals used during the setup after installation or during maintenance work Front face of intelligent Touch Manager SERVICE LAN The port for temporarily connecting the intelligent Touch Manager to a LAN from its front face instead of its rear face during the operations such as installation or maintenance LAN SW This is for switching between the LAN port on the back and the SERVICE LAN port on the front You cannot close the cover when the switch set to FRONT To close the cover select BACK BACKUP The switch for turning on off the backup power supply for retaining the current settings DIII MASTER The switch for setting MASTER or SLAVE when there are multiple DIII NET centralized controllers such as intelligent Touch Manager CPU ALIVE LED Green The LED that indicates that the CPU is operating nor mally The CPU is operating normally when this LED is blinking and malfunctioning when it is on or off It takes about 10 seconds for detection of the abnormality On Software error Off Hardware error or power off LAN LINK LED Green The LED that indicates whether or not the hardware
42. until all connections are made Not doing so may cause an electric shock Terminal location and schematic connection diagram lt Schematic power connection dia gram gt Connect the power supply to the three terminals L Live N Neutral and ground in the POWER sec tion A Earth B Earth leakage breaker C Power supply 24VAC 60 Hz Installation Manual 3P291714 2B 23 DCM601A71 intelligent Touch Manager 2 1 2 24 Wiring specifications Cable type Ordinary tough rubber sheathed cord 60245 IEC 53 equivalent or higher Ordinary polyvinyl chloride sheathed cord 60227 IEC 53 equivalent or higher Core thickness Power wire AWG 17 14 Earth lead Size must comply with local codes Terminal treatment Use a round crimp type terminal M4 with insulating sleeve Power supply voltage Single phase 24 VAC at 60 Hz Voltage fluctuation 10 or less Electric power consumption 23 W N CAUTION An earth leakage breaker capable of shutting down power supply to the entire system must be installed Turning on off the earth leakage breaker turns on off the power supply to the intelligent Touch Manager When using an earth leakage breaker make sure to select one useful for to protection against overcurrent and short circuit When using an earth leakage breaker only for earth device make sure to use a wiring interrupter together The power supply requires
43. with intelligent Touch Manager C Wall opening dimensions Use the following dimensional drawing to provide a sufficient opening NOTE The supplied paper template helps you mark the dimensions of the required wall opening Use the supplied paper template Flush wall mounting Wall opening dimensions for flush wall mounting 10 5 32 24 4 i A B 8 13 16 8 5 16 c i D y 9 4 gt e 9 1 2 in A Inner wall material B Beams of building frame C intelligent Touch Manager D 2 3 8 E Opening Installation Manual 3P291714 2B 27 DCM601A71 intelligent Touch Manager 3 2 3 Installation procedure 1 Insertthe mounting frame bracket and angle brackets into the wall opening and secure them to the wall in such a manner that the wall is sandwiched between the brackets with flat head screws NOTE You need to route in advance the cables connected to the rear face of the intelligent Touch Manager through the cable hole provided at the bottom of the frame bracket Install the rear face terminal cover while the intelligent Touch Manager is removed Securing frame bracket and angle brackets Sc Wall Flat head screw Frame bracket Angle bracket 000 gt NOTE When securing the frame bracket be careful not to drop the angle brackets inside the wall 2 Remov