Home
MILK POINT CONTROLLER
Contents
1. 5 hours step C Custom line A Don t ify to setup during milking sta Milk Point Controller 7 User manual 3 2 6 Database This form need to select the file of the database of the milking data if it is the first activation set the file Program gt MilkPointController_V6 gt MilkDB mdb that is the default Software setup Farm information Currently database path Communication C SviluppoMPC FULL_V6 MilkDB mdb Milking parlour setup Select working database Milking session Create a database backup Milkings deleting from database Feeder system Cows deleting from database Database Software settings A Don t apply modify to setup during milking status The other control needed for managing the database but attention that old data could be lost so utilize only if you Know wath to do It s recommended to create periodically backup of the working database in order to keep light the database for the storing of the milking When you create a backup of the database it s recommended to Clear the milking button Milking deleting In the current database so you can restart with a clean milking database that maintaining all the stored COWS Milk Point Controller 7 User manual 3 2 7 Software settings This form need to check directly if any update are available for set the language and the measure unit that Software setup Farm information Software information Commu
2. milking message is received from the PC in 2 hours the MPC automatically switch to the next milking session If the previous session was just the last session the MPC lock any other START milking message M farm information detail Farm name and farm address 3 1 1 Milk board indication aa i The milk board could be show in two different way a 1 Position 19 If the milk place is in line and work on 2 Position 20 If the milk plase is out of line or there is problem on the CAN connection Milk Point Controller 7 User manual 3 1 2 Milk place Cow status The indication of the status of the place could be show in different way ABS erie th 1 Position 17 If the milk place are free or a cow not identified are in milking PGM Milk temp Milking time Total milk 2 Position 18 A cow indetified is in milking green M indicates that cow is manually entered not automatically identified Position 19 A cow was in stop milking status grey Position 20 Milk place is in wash If put the mouse pointer over a cow in milk are show the milking information like in picture b it is possible to see alarm presence milking program milk temperature milking time and the milk yeld of the cow Milk Point Controller 7 User manual 3 2 Software Setup The Software setup menu permit to customize the MPC for the parlour before to start to work the user must configure the
3. This date nern romm xo EA Is calculated adding 280 days to the Execute Calf born Milking periods Insemination date Insemination Soca along NO Calf born date of the calf birth ieee Feeder Confirmed status of the insemination Total cows 731 Milk Point Controller 7 User manual 3 8 4 Treatments From here it s possible to handle the treatments of the cow COWS MANAGER N CowID IDTAG Treatment Veterinary name Notes Cow ID 41 Total lactation prod 779 62Kg Total cows 731 el da 6 Date date of the treatment Treatment description of the treatment Veterinary name the name of the veteri_ nary Notes notes to included to the treatment Date 21 03 2010 Treatment test optional Veterinary name veterinary test m Feeder Feeder Milk Point Controller 7 User manual 3 8 5 Feeder MilkPointController provides two types of feeder system e Basic line totally handled by MPC and Panazoo milking stations e Custom line handled by Wasserbauer feeding machine and coordinated by MPC software The feeder typology can be selected in software setup Basic line Feed per milking 2 Feed per milking3 Feed per milking 4 Delete food Daily feeder distribution Cow ID 10 l Hour Percent Grammes a Set same percent Total lactation prod 1033 47Kg Food name Milk temp average 35 4 C Food test
4. 14 01 2010 3 4 Wash Milk Point Controller 7 User manual This function permit to show and save the data in the selected period range Chart 24 08 2009 16 22 47 24 08 2009 16 27 47 24 08 2009 16 28 46 24 08 2009 16 34 07 24 08 2009 16 57 59 24 08 2009 17 05 48 24 08 2009 17 16 56 10 09 2009 11 45 33 10 09 2009 11 46 36 10 09 2009 12 12 06 10 09 2009 12 15 09 10 09 2009 12 41 13 10 09 2009 14 14 50 11 09 2009 6 46 46 11 09 2009 8 31 04 11 09 2009 8 57 31 11 09 2009 9 31 38 11 09 2009 11 27 50 11 09 2009 12 53 14 11 09 2009 13 01 50 11 09 2009 13 03 22 11 09 2009 17 57 19 11 09 2009 17 59 10 11 09 2009 19 50 11 12 09 2009 6 52 43 12 09 2009 7 00 05 12 09 2009 8 32 02 12 09 2009 8 55 58 12 09 2009 9 36 22 12 09 2009 17 36 34 12 09 2009 19 09 53 12 09 2009 19 12 52 13 09 2009 7 10 49 13 09 2009 8 57 34 13 09 2009 9 24 01 13 09 2009 9 58 58 13 09 2009 17 31 10 00m 15s 00m 28s 00m 05s 00m 23s 07m 49s 00m 19s 00m 07s 00m 20s 00m 18s 00m 10s 00m 24s 00m 38s 00m 18s 00m 20s 07m 01s 16m 59s 07m 02s 00m 14s 00m 30s 03m 12s 00m 27s 00m 14s 01m 07s 07m 04s 01m 15s 00m 23s 07m 03s 17m 00s 07m 03s 00m 55s 05m 43s 02m 47s 00m 18s 07m 01s 17m 00s 07m 02s 02m 10s gt 40 C 16m 11s gt 40 C 14m 51s gt 40 C 16m 05s 3 5 Report This function permit to elaborate produce print and export the report of the production there are some filters to select REPORT AND PRODUC
5. 2 14 00 Feeder system Session 3 22 00 Database Software settings End session wait 120 minutes Syncronize A Milking session is valid from 00 00 to 23 59 A Don t apply modify to setup during milking status OK Quantity number of milking sessions 2 or 3 Sessions timetable time period of the sessions End session wait when all the milking station are in IDLE status no milking a minutes counter start If no other milking is registred in the minutes setting the MPC automatically switch to the next session If the current session is the last no other milking will be stored in database 3 2 5 Feeder system This form need to setup the type of the feeder system if it is present It is possible to select 1 None if no feed system are present or there is the Feed in parlour with Global ID Feed device 2 The Basic Feed if thera are in the farm some feed station for this modality it is possible the interval for dispence the feed the time for start the feeding 3 Custom for custom feeding system implemented with Wasserbauer device It is possible also activate for the feed in parlour systems the auto dispence syncronized with milking gate closing Software setup Farm information Communication Milking parlour setup Milking session Feeder system Database Software settings Milk Point Controller 7 User manual C None Basic line In parlour feed Feeder distribution interval C 4 hour step
6. GB Copyright 2010 Panazoo Italiana s r l All rights reserved http www panazoo it Milk Point Controller 7 User manual Waiting for the complete installation of the software g Milk Point Controller 6 Setup Milis Point Controller 5 E MikPointContole Sp Installing Files C Program Files Milk PointController_v6 MPC exe amame Copyright O 2010 Panazoo Italiana s r l All rights reserved http www panazoo it If you using a Wasserbauer Feeder machine connected to MPC the MPC installation provides all the necessary drivers for the correct communication If you don t use this feeder system you can bypass this drivers installation and click Exit setup InstallShield Wizard Setup Type Choose the setup type that best suits your needs Importants Message You already Installed driver to select one of items to operate it C Re install Upgrade C Uninstaller driver Milk Point Controller 7 User manual Now MPC must install all the Ixxat Can drivers for the correct communication to the G ID or other Panazoo Milking station Click next and se vaz Welcome to the VCI 2 18 0 1813 Setup Wizard The Virtual Card Interface is a system extension intended to enable applications uniform access to different IXXAT Interfaces lt is recommended that you close all other Applications before contir vir Y Click Next to continue or Cancel to exit Setup At the end of the Ixxat Can
7. Milking length average 8min Food portion 5 Kg 05 00 10 00 Milking flow Kg min 1 7Kg min Cow parameters Milking periods 10 00 15 00 Insemination Treatments Feeder _PANAzoo PANAZOO 15 00 20 00 feeder system Sort gate Total cows 731 ww e 4 se A Basic line feeder consist of 4 aliment daily distributed in different periods this means that a cow is enabled to eat only 1 time in a period a day This periods can be subdivided in this way e Once every 5 hours e Once every 1 hour In both case the feeder system work for a total of 20 hours In the remaining 4 hours the feeder system is switched off Start hour and period selection can be set in software setup For each food it s possible to set Food name and Food portion Food portion is automatic distributed in the day according to the Percent set value The default setting of the percent value is 25 for 5 hours period and 5 for 1 hour period distribution Anyway the percent values of every distribution period can be manually modify but the necessary condition is that the total amount of the percent values must be 100 The Grammes display is automatic updated at every change of the food portion according to the setting of the percent value Milk Point Controller 7 User manual 3 8 6 Sort gate IDTAG Scroll cows gt Y Enable Disable sort gate O Total
8. application Attention at the first run of the MPC application some warning messages are showed are not important they are showed because the system was not configured Now are describe all the step needed to follow before start with the milk activities This information are important for specialized person that install the Panazoo milking system 3 2 1 Farm information This form need to insert the information of the owner of the parlour Software setup Farm information Farm name Mr Red Communication Milking parlour setup Address Street Milking session Feeder system Country Italy Database Software settings Tel 39 00 email red red it A Don t apply modify to setup during milking status 3 2 2 Communication This form need to select the type of communication board are connected to the PC and if the identification system is with walk true gate or with one antenna for milking place available for the goat system Milk Point Controller 7 User manual Software setup Farm information Communication Milking parlour setup Milking session Feeder system Database Software settings Antenna type selection C Individual Walk through A Don t apply modify to setup during milking status All the CAN communication interfaces are provided by Ixxat www ixxat com Drivers are fully supplied and installed by MilkPointController in the application setup With UsbToCan Compact
9. e Cowld automatically calculated by adding 1 to the last cowid detected in database Otherwise you can always change this e Birth date the birth date of the cow 3 8 2 Milking periods Milk Point Controller 7 User manual Cow name the name of the cow Status milking standard status for the cow with no lock dry cow in dry status dry with lock cow in dry status but during the identification the MPC send to the milking station a LOCK that will be visualized on the display of the milking station Set0 value of parameter Set0 ISC value of parameter ISC Group number of the cow lot ISO IDTAG the idtag number associated to the cow Milking lock it s possible to set a lock for a cow In this case when the cow will be identified by the antenna the MPC send a COW LOCK message to the milking station and this information is showed on the display of the milking station If you activate lock this can be forever always in lock or with expiry date lock until Lactation Nr the number of the current lactation Lactation number is automatically increased at every calving Start first milking date of the current lactation This date can be manually set or automatically by MPC at the first milking of the cow Feed per milking feed portion This feed is handled directly by the milking station Milking days an indicator of the current lactation days milking Total lactation
10. 13 88 17 54 15 79 17 33 15 51 Am ma Milk Point Controller 7 User manual Y axis min Y axis max Autoscale Milk temp 35 35 5 36 5 35 5 34 5 36 36 35 5 36 34 5 36 35 5 35 5 36 5 35 5 listbox in the selected date range Result table shows result sorted by Cowld gt Date gt Time Milk Point Controller 7 User manual 3 6 Curves This function permit to show the curves of production temperature ISC and milking time for the last 31 days of activity 03 01 2010 02 01 2010 01 01 2010 31 12 2009 30 12 2009 29 12 2009 28 12 2009 27 12 2009 16 12 2009 15 12 2009 With Y axis min and Y axis max controls it s possible to set the Y axis range values for the visualization Autoscale button automatically set this values Milk Point Controller 7 User manual 3 7 Board Setting This funtion is accessible from the menu and with double click on the milkING boards simbols with this panel is possible to modify some parameters of the milking boards from the remote station Board node Board description Parameter group GloballD Panazoo General Settings GLID Parameter list Step Val Descr CONTRAST 5 Set contrast value of LCD display 0 10 LANGUAGE 0 English 0 Italian 1 Francaise 2 PWM_TYPE 0 Power Supply type AC or DC 0 DC 1 AC PROGRAM_LOCK 0 Lock the milking programm in the print MEASURE_UNIT O European 0 U S Type 1 ENABLE_ISC 1 Enab
11. Manager form or because are past 220 days after insemination date E Heat detection A list of all the cows with heat detection Heat status is detected by the software monitoring the average of the milk production in the last 5 sessions If the production in the current session is less then 30 of the average of the last 5 sessions this cow is in heat status F Aktiv cow alarms Milk Point Controller 7 User manual G Wash Information about wash session last wash session date time maximum water temperature minimum water temperature and length of the wash session Wash data are constantly saved in database and are summarized in table Wash data that is linked in main menu H menu Main menu button explained in chapter 3 1 3 Post N I gate switch connection info For example in a Double Line parlour are 2 gate switch one for the left side and one for the right side MPC during your loading detects the presence of these switch connected to the Antenna board or G ID board L Other MPC info Current session the number of the current milking session 1 or 2 or 3 depending on your configuration farm setup Farm typology the farm type setting in software setup double line single line swing over etc Minutes to new session from every last STOP milking message received by a global id or other milking station Panazoo the software start a minutes counter If no other START
12. Milk Point Controller 7 User manual MILK POINT CONTROLLER User Manual SW Ver Manual Ver Description Checked 7 0 1 01 GP 6 15 1 01 Detailed all menus and functions of the MPC GP 6 14 1 00 First edition MA Milk Point Controller 7 User manual Sommario Mg CMS TAN VS SC ON ARE OI csc cg nace tees A 3 DONA Al TINS Gel AMOI coca ees ce tes tse ea dee Seine nn II oer O EE 3 24 Resource MMM tease stesodusseuvadeotteadsuventadesvearseaens 6 2 IO olas 7 A SO A 8 AAA A A O A E tent 9 A Sn E E 10 Se MIDA indication coso pcotreoelacci e i E EAA EAE 11 31 2 PAC COWS bat US saco ea 12 D2 OME Ale A e a E E E EOI A 13 A a A e POE A 13 SOJA E orar o A E E E oats toaniesesqscoldesienne 13 SPA A soseveeetareqnataaduedeteadee tudedtesaxtsseosesestaneaiedeeenraee 15 A E 16 sn A a 16 Sa Dio A PI E oi O EA 18 AS O EE A feuahwiesprensaeteeseaace 19 CO A 20 A A 21 IR 0 0 e OO OMPI PER E e ePOS A 22 SA e ANUN yn A A 23 Sn DOMO S dde 24 A Is e ono A 25 ANO AA o E sale nem ase 21 IA A 28 A AAA PP sacs cedes T 29 A E A rund 30 e e 5 estes E 31 Dic NL E e E E ec ieee E ese e ee eee aes veces 32 Milk Point Controller 7 User manual 1 General description This manual describe functionality of the application Milk Point Controller MPC abbreviation and the information for his utilize 2 Software installation For the installation of the MPC insert the MPC CD in the CD drive and ru
13. TION ANALYSIS Report selection Milk production by Cow D CowlD 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 IDTAG 139714974 139714974 139714974 139714974 139714974 139714974 139714974 139714974 139714974 139714974 139714974 139714974 139714974 139714974 139714974 139714974 139714974 139714974 139714974 139714974 139714974 139714974 139714974 ANNATA ATA ee ee ee ee ee ee ee ee ee ee ee ee ee Group Date 01 10 2009 02 10 2009 02 10 2009 03 10 2009 03 10 2009 04 10 2009 05 10 2009 06 10 2009 06 10 2009 07 10 2009 07 10 2009 08 10 2009 08 10 2009 09 10 2009 09 10 2009 10 10 2009 10 10 2009 11 10 2009 11 10 2009 12 10 2009 12 10 2009 13 10 2009 13 10 2009 AATANIOONONN Description of the available reports Milk Production by Cowld a report that summarizes all the milkings of the cows selected in the Cowld 18 39 04 7 51 31 18 52 21 8 01 18 18 27 09 18 20 45 7 42 45 7 27 02 18 40 33 7 27 07 18 33 28 8 02 11 18 57 58 8 15 16 18 32 41 8 25 53 18 10 44 7 40 22 18 20 34 7 48 29 19 27 25 8 08 25 18 47 42 S1 Kg 14 06 17 89 0 17 14 0 0 18 36 18 24 0 17 96 0 17 75 0 18 98 0 19 44 0 16 85 0 17 54 06 08 2009 3 Kg 20000000 00000000000000o0o00 To 15 10 2009 Milk total 14 06 17 89 13 6 17 14 14 43 15 2 18 36 18 24 14 06 17 96 13 96 17 75 13 8 18 98 14 05 19 44 13 17 16 85
14. drivers setup the MPC installation is completed and you must reboot your system After reboot PC you must connect your Ixxat USB device and let the PC automatically installing the device E Milk Point Controller 6 Setup E Installation Successful Milk Point Controller 6 installation is complete Thank you for choosing Milk Point Controller 6 Please click Finish to exit this installer Milk Point Controller 7 User manual 2 1 Resource requirement For install and run the MPC application please verify your PC and operating system charatteristics 1 oe system supported Windows 2000 Windows XP Windows Vista 32bit and Windows 7 32 it 2 Number 1 USB port available 2 Gbyte of RAM minimun 4 CPU Pentium or highest Operating system of 64 bit are not yet supported Milk Point Controller 7 User manual 2 2 Update For a better functionality of the MilkPointController software please check on the Panazoo web site htto Awww panazoo it mpc if there are service pack available if there are download the file and run on your PC Panazoo MPC service pack page y BS s x 5 Bing Milk Point Controller User manual Download Milk Point Controller Service Pack Description YO eee ee Add rotary 40 post 15 09 2009 Uniform Taurus upgrade at version 1 0 17 Engineering unit selection of temperature C F and weight Kg Ib Download Improvement of automatic milkings download for p
15. idate the warranty conditions PANAzoo ltalia SrL Via N copernico 2 4 20082 Binasco Mi Tel 39 02 9054833 Fax 39 02 90091860 e mail info panazoo it web www panazoo it Innovation in Milking system
16. ing C Dry with lock Milking flow Kg min 1 2Kg min L Seto 12 es Cow parameters ISO IDTAG 1770349 Milking lock Lock until Always in lock 1 Feed per milking 0 16108 2009 Milking days 221 Sort gate IVI al Total cows 731 N daa 1D In the top of the window there is a search bar from which is possible to search a specific animal in the database The search can be by Cowld or by IdTag In the left fo the window there is a summary cow info from which it s possible to view the Total lactation period total milking amount in the current lactation Milk temp average Milking length average and Milking flow calculated by TotalMilk MilkingLength In the bottom left there is an indication of the total cows stored in the MPC database In the bottom right there there are buttons functions Multiple cows configuration saving Milk Point Controller 7 User manual Pressing this button MPC shows a window like this Save config to all cows Set0 25 ISC 30 Only for Swing Over parlour Feeder Multiply feed Save config to all cows y Here it s possible to set some configuration automatically to all the cows stored in the database This common configuration are Set0 ISC and Feeder only for swing over parlour Milk Point Controller 7 User manual Pressing this button a window let you choose to print one
17. ipeline devices Soffimat Plus 25 09 2009 Feed command enabled for all parlour types Basic line feeder improvment Download Languages updated 28 10 2009 Deleted message informing the end of milking sessions Download Fixed graphic icon in message box during settings saving ba Fine Internet Modalit protetta disattivata fa y Q105 v If your MPC working version is older then the last service pack uploaded in Panazoo Service Pack page download it and the install Click next and service pack will be installed on your machine MilkPointController Service Pack v6 14 Welcome to the installer of Milk PointController This setup upgrade your MilkPointController to version 6 14 it is strongly recommended that you ext all Windows programs before continuing with this installation If you have any other programs running please click Cancel Otherwise click Next to continue 22 Milk Point Controller Service Pack Installation Successful The Milk Point Controller Service Pack 6 14 installation is complete Thank you for choosing Milk Point Controller Service Pack Please click Finish to exit this installer Milk Point Controller 7 User manual 2 3 Preliminary action For the first activation of the system please follow this step 1 Connect the USB card to the PC 2 Start MilkPointController and activate the software with your license key number supplied with Ixxat Can I
18. it s possible to connect up to 32 can nodes so 30 milking station and 2 antenna boards With UsbToCan II it s possible to connect up to 127 can nodes for each of the two Can Line 3 2 3 Milk parlour setup This form need to set the type of parlour present the number to insert in the cow standing is the number of the milking place and not the number of the milking board this two number are different only for swing over systems from here it is also possible select the sort gate system is presence Software setup Farm information Communication Milking parlour setup Milking session Feeder system Database Software settings ly modify to se A Don t duri Farm typology Cow standings Double line Single line C Rotary C Swing over Sort gate not present milking status Milk Point Controller 7 User manual 2 y Pree LL LLLI LELI LLLI Ak PTT TTT TTT TTT TTT TT O99 0 RARA ESS PETTITT PITTI EE i l Ii i koro ao present Milk Point Controller 7 User manual 3 2 4 Milking session This form need to set the number of the milking session for the farm and the typical time of the star sessiones The Syncronize push button must be pressed AFTER the first reboot of the application and after the activation code insertion Software setup Farm information Communication Milking parlour setup Sessions timetable DR Session 1 06 00 Session
19. lactation prod 597 76Kg Always separate Milk temp average 34 90 Milking length average 6min Separate until Milking flow Kg min Separate after conductivity alarm Cow parameters Milking periods Separate cow in Box1 Insemination Box2 Treatments Feeder Sort gate Total cows 731 Sort gate it s a physical gate installed in the farm from which it s possible to separate specific cows This separation can be enabled disabled in this tab that is the last setting of the cow manager There are 3 methods to separate a cow e Always separated the cow will be always separated with no conditions e Separate until the cow will be separated until the setting date Separate after conductivity alarm during a milking session if the milking station detect a O conductivity alarm A cow can be separated in 2 different destination box Milk Point Controller 7 User manual Warranties PANAZOO Innovation in Milking System Panazoo ltalia S r l will replace at no charge for 1 year period from the date of purchase any part which results defective in terms of material or workmanship after checking the part on our premises in Binasco Ml Italy the buyer will bear all transport costs for shipping the detective materials for substitution within the terms of this warranty The removal of the identification label on the electronic card will inval
20. le the conductivity control EDGE_ISC 25 Level Conductivity from 0 to 60 30 300 000 scc DELAY_ISC 3 Delay ISC control 3 300 gr MCMD O Enable Master Wash Function MCID 20 Master Wash Source ID Clicking this button you save the parameter on the board node milking station selected Clicking this button it s possible to save the parameter to all the milking stations connected to the CAN network Milk Point Controller 7 User manual 3 8 Cows Manager Group Set0 ISC Milking lock PGM1 PGM2 PGM3 Cow name Feed per milkinc 30 30 SIMENTAL 0648 3 SIMENTAL ABASI HOLSTEIN VICDAN SIMENTAL CIGDEM SIMENTAL GULSUM SIMENTAL DILARA SIMENTAL BONCUK SIMENTAL YAZGULL SIMENTAL NURDAN HOLSTEIN BENEKLI HOLSTEIN 4036 HOLSTEIN GUZGULL SIMENTAL SUKRAN HOLSTEIN SUZI SIMENTAL PERVIN SIMENTAL CEYLAN HOLSTEIN GIZEM MONTOFON KASTOI HOLSTEIN ZARIFE UAI CTEIN ill CAL Total cows 21 In cow manager you can handle all your animals database Add modify remove cows add inseminations treatments feeder data etc FiSCiCo olio ioioio i oioioCoioioc ioCoioioioioioio o amp E ad ad ad ad ed ed A LS SO RD RD AD AD ot OO Double click on a cow in the list for modify the configuration of a cow COWS MANAGER CowiD 17 Cow ID 17 Birth date 04 08 2005 Cow name Cowld 17 inserted by Uniform Total lactation prod 760 08Kg Milk temp average 35 0 C Status Milki Milking length average 10min id
21. n the setup exe application follow the indication of the Setup Wizard If an old version of the MPC was instolled on the PC please BEFORE install a new version uninstall old MPC and from Windows Control Panel remove all IXXAT software reboot PC and run VClclean exe application select scan amp delete option and select the drive of your PC where the MPC application was installed Milk Point Controller 6 Setup Mils Point Controller 3 a 7 Milk Point Controller 6 Setup Milk Point Controller Milk Point Controller use CanOpen protocol and needs IXXAT Can Interface driver to work The setup will install all Can libreries and dil for the correct working of the software kt is strongly recommended that you ext all Windows programs ff you have any other programs running please click Cancel Copyright 2010 Panazoo Italiana s r l All rights reserved http Awww panazoo it Selection of the MPC installation folder U Milk Point Controller 6 Setup Wilks Point Controller y IB Milk Point Controller 6 Setup Installation Folder Where would you like Milk Point Controller 6 to be installed The software will be installed in the folder listed below To select a different location either type in a new path or click Change to browse for an existing folder Install Milk Point Controller 6 to C Program Files Milk PointController_v6 Space required 76 0 MB Space available on selected drive 29 60
22. nication MilkPointController V 6 10 0 Language UNITED KINGDOM va Milking parlour setup Milking session Feeder system Engineering units fe C fe Kg Database CF C Ib Software settings Webcam configuration No webcam selected Shift system iv Enable Disable Sfift A Don t apply modify to setup during milking status Language Select an available language for the MPC If MPC is not available for your language or if you want to apply some modifies to your language click the button Ex This will run a tool Language Editor from which you can modify or create a new MPC language Engineering units Setting of the measurements units used in the software and in the reports Webcam configuration If you want to use a webcam to monitoring farm status after you have installed all the necessary drivers to the correct working of the webcam select it for using in the MPC After a reboot of the software you can enabling the visualization of the webcam from the main menu button Webcam Shift system It is possible also set the webcam presence and enabling the Shift functionality PAY ATTENTION This setting MUST BE THE SAME OF THE MILKING BOARD Milk Point Controller 7 User manual 3 3 Feeder This function show all feed dispensed divided for cow in the bottom it is possible select one cow or all cow CowID Date 1282 14 01 2010 1284 14 01 2010 15 20 14 01 2010 1284 1282
23. nterface At the first loading the MPC show you the license activation form Insert all information and copy the license key in the Software activation key field 3 Configuring your farm following the configuration information in chapter 3 2 Milk Point Controller 7 User manual 3 View description In this section are described all window of the application and the action that user can performe Milk Point Controller 7 User manual 3 1 Main view The main window show the status of the parlour in the top there is a rappresentation of the parlour with the exact number of milk place the status of the gate and the status of the cow Peeeeeeees ee ek 1452 23 Launch sessions of day 1401 2010 14 52 24 CAM network initialized 14 52 24 System turn OM and ready to work A Event list A log of all the MPC and milking station activities B On milking now A list of all the cow in Milking status in the farm Every cow is detailed with Post Nr Cowld and realtime milking production With button it s possible to switch visualization to Chart In this modality is show a bar chart of every cow in milking status C Day production The total of the daily milk production divided by the number of milking sessions set in software setup D Dry cows A list of of all the dry cows A cow can be in dry status because of a manual setting in dry status in Cow
24. of this report a PI J Lowild b inserted Dy e Print single cow list print a PDF y 2d b i PRINT MANAGER d report of the single cow selected in cow list This report contain all y Print single cow detail Print complete cows list the settings and information about Confirmed inseminations the selected cow Not confirmed inseminations Dry cows e Print complete cow list print a PDF report containing the list of ia all the cows stored in database e Confirmed inseminations print a PDF containing a list of the confirmed cows insemination e Not confirmed inseminations print a PDF containing a list of the NOT confirmed cows inseminations e Dry cows print a PDF containing a list of the actually dry cows 3 8 1 Cow parameters Clicking this button you can add a cow in the database with the user interface For each cow in database it s possible to set custom milking parameters cow data info feeder and many other parameters Field with symbol are obligatory for the correct storing of the cow Cow ID Birth date Cow name Cow ID 9956 Total lactation prod Milk temp average Status Milking C Dry with lock Milking length average Milking flow Kg min Seto 12 gt Milking periods Milking lock Lock until Insemination Always in lock Treatments Feeder Feed per milking Milking days Sort gate Total cows 21
25. prod Milk temp average Milking length average Milking flow Kg min 120 days P5 VV 1 PULS MIN PULS MIN PULS MIN RATIO F RATIO F RATIO F RATIO R RATIO R RATIO R PULS MIN PULS MIN PULS MIN RATIO F RATIO F RATIO F Milking periods Insemination Treatments Milk production Sort gate Total cows 21 From here it s possible to set 3 custom milking program for the cow Milk Point Controller 7 User manual The 3 program are automatically applied by the MPC with this method First milking date gt 90 days gt 120 days gt till the end PGM1 PGM2 PGM3 ES Clicking this button it s possible to apply the milking program to all the cows stored in database 3 8 3 Insemination COWS MANAGER Ss Scroticows e Execute Forecast birth Birth Bull name Confirmed 1 29 10 2009 21 07 2009 Data from Uniform SI Cow ID 2 O Total lactation prod 590 86Kg Milk temp average 34 9 C Milking length average 6min Milking flow Kg min 1 4Kg min Milking periods Total cows 731 d e From here it s possible to handle the cow inseminations Clicking Add new MPC show you this form where you can store the insemination data Execute date of the insemination pose es Days after ins days past after insemination date rotatactationproa soo a Bull name name of the bull ER Days after ins Forecast birth date of the forecast birth
Download Pdf Manuals