Home

USER MANUAL

image

Contents

1. picture2 picture3 picture4 pictured hole for main part 70 A hole for 3 T hole for f A main part main part M 1 480 ron 38 i jJ 90 en lock b lt fix screw 3 is fix screw A Sa O O table clip wall clip guide rail clip floor prop Vil Assembly and debugging Open the packing box check whether there are missing parts or damage phenomenon ofthe products according to the product list If there is any problem please contact with the dealer or manufacturer in time to get solved properly 1 Wall hung style check lamp first determine the position of clip size is as shown in picture 2 Using a drill to dig four 10 mm holes with 25 mm depth Plug the wooden stopper into the hole with a hammer fix the hanging fixture with tapping screws Screw out the lock screw on the connecting pin of the lamp insert the connecting pin into the hole and screw down the screws 2 Table clip style check lamp first install the clip picture 3 in desktop or mesa satisfying position lock the fixed screw to make the clip firmed 9 in the desktop or mesa Screw out the lock screw on the connecting pin of the lamp insert the connecting pin into the hole and screw down the screws 3 Guide rail clip style check lamp adjust the bolt to the right size according to the track picture 4 carry forward it into orbit and lock it Screw out the lock screw on the connecting pin of the lamp insert the connecting pin into the hole
2. Fault phenomena Turn on the power Power lines have Connect fo the switch the indicator is no electricity circuit where there is not bright electricity supply The power cord is Reconnect the not connected well power cord Change the fuse Turn on the power Brightness Transfer the switch the indicator is adjusting button is not brightness adjusting bright but the lamp is open button to the not bright maximum Flare adjusting ring Transfer the is not open flare adjusting ring to the maximum System line fault Contact with the after sale service department for solution Other fault Contact with the after sale service department for solution XI Replacement of bulbs The method of bulb replacement 1 Choose halogen bulbs with the same model and specification 2 You must turn off the power switch and pull out AC power cable before the replacement 3 Back off the green waist ring on the lampshade 4 Use a pointed plier to take off the spring of the bulb hook 5 Take out the old bulb change the new bulb 6 Re install the green waist ring a ay Pi A SZ a r7 gy gt gt Y ae lt 2 y v U stepl step2 step3 XII After sales service warranty Warranty of 18 months provide maintenance service all user s life in the warranty period in normally using the trouble because of the product quality the consumer depends on the warranty slip and invoice enjoys free maintena
3. CO O Content I Brief introduction 2 0 21 0120 i4chcstesicdeiae deede es ll Performance Summarize 046 KD 201C Local Examination Lamp Ill Main technical parameters U S E R M AN U AL IV Security tips and symbol instructions V Working Environment a m aa dass adeuses VI Produ ilist H Sa www ww ee eee X Failure Judgment and Eliminating Methods XI Replacement of bulbs 0 0005 XI After sales service warranty 0 6 X IiTransportation and storage conditions X IV Electrical schematic diagram and components I Brief introduction Model KD 201C Scope of application This product is a local auxiliary check lamp designed for doctors and nurses in diagnosis and treatment process which demand higher for local lighting It is mostly used in outpatient visit and miniature operation occasion Characteristic Small can be bent freely can be used together with wall clip ceiling clip table clip and floor prop wide serviceability Product component Lamp holder hose power box support parts and power cord ll Performance Summarize The check lamp is designed with low voltage cold lighting system and high power LED lighting source safe and reliable Lamp holder has the function of curve transfer and rotating Convenient safe and reliable The design and production of this light source stri
4. and screw down the screws 4 Floor prop style check lamp first install the chassis pulley in place then contrapuntal connect the base and the strut and the lamp m o Ek ro Lock the screw Please Operate as C IRERO the diagram A B C MERU i A B ai C FI amp lt 5 3 S Install according to the steps above the lamp can work Turn on the power switch the lamp begins to work 5 Debugging a bending the hose you get the right lighting position and angle b debugging the height of the support you can get the right illume height c brightness adjusting knob in picture1 can change the lighting intensity d flare adjusting ring in picture1 can change the spot size IX Note 1 Please pull out the power plug before clean the lamp do not use liquid spray to clean it 2 When install the lamp please assemble and reinforce it according to the instruction of the technical requirements 3 Do not use the lamp near water 4 You should do the bulb replacement after the bulb is cool 5 The maintenance installation commissioning of the lamp should be operated by professional 6 Never put any item on the power line 7 The old bulbs should be put in the trash can avoid human body scratch by the glass pieces 8 The light intensity of illumination is higher you should be cautious in use with your eyes X Failure Judgment and Eliminating Methods It should be operated by the professionals
5. ce arko 2y 1 Warranty card Company name Address Phone No Product name Serial Manufacture Number date Sale date Fault description Remark The warranty of our products is 18 months since the release date Please truthfully fill in this form cut it according to the dotted line and send it back to our company thank you for your cooperation Maintenance card Company name Address Phone No Product name Serial Manufacture Number date Sale date Fault description Remark You can enjoy seventy percent discount for the maintenance services even if you use this card over the quality assurance period 9
6. ctly executes the first part of the safety requirements of medical electrical equipment GB4793 1 2007 general requirements are guaranteed in safety lll Main technical parameters Input voltage 90V 240V 50HZ 60HZ Lamp power 35WL 50W Input power lt 60W Color temperature 3600K 500K Fuse protector 2A IV Security tips and symbol instructions 1 When the check lamp is in use you should always abide by the basic safety precautions in order to avoid fire electric shock or the risk of injury 1 Please read the instructions carefully and operating according to the specifications and requirements 9 2 When replace the bulbs you must first turn off the power switch and pull out the power cord 3 The replacement of fuse protector should be the same with the mark 2 The introduction of the following symbols JAN Attention Check the random documents 2 Protect the grounding C Disconnect the power V Working Environment A Environmental temperature 10 C 40 C B Relative humidity lt 75 C The atmosphere 86 0 106 0kPa Connect the power VI Product list Check lamp one power line one Fixture table clip guide rail clip wall clip O Floor prop fixed floor prop lift floor prop Vil Product interface 1 Master device of KD 201C DOOHS D N 7 BJ lock screw connecting pin power switch power box brightness control hose lamp holder flare adjusting ring 2 Fixture interface
7. nce service if the error caused by refitted or install other functions which is without our company s permission is not within the scope of warranty 000 0 25M i Adjustable 2K resistance if the model number release date is modified deleted moved or unrecognized will not enjoy the maintenance service The error caused by human factor such as falling squeezing dip in wetting etc is not within the scope of warranty Once receiving the goods please sign and accept it after opening the package to inspect and confirm whether the instrument is crushed scratched or not Make sure there is no special unnumbered inside If the goods are damaged and you did not 100nf 400V 473J 630V Powerswin E E 8 SS 3 I Power 30W ji 10 o ransom o E E i inspect before sign it it will be at your own risk Silicon BTAO6D X IITransportation and storage conditions one pee F2Ae1260 A Environmental eer ie 40 C 59 C Any products may be updated or improved The change of circuit or B Relative humidity lt 70 element specifications of the product will not with prior notice C The atmosphere 50Kpa 106Kpa 2012 edition X IV Electrical schematic diagram and components list 24k 39 g P RI T SW SPST 3 205 Wl AC200VIN cl 2 4000 100n Specification Quantity 1 Circuit board 1 o Bilateral diode s Resistance 21020 1 a Resistance 390 020 1 5 Resistan

Download Pdf Manuals

image

Related Search

Related Contents

Five Piece Door User Manual  Renesas R0E436049CFJ10 User's Manual  none 42,000 BTU Patio Heater Instructions / Assembly  DOSarrest Security Services User Guide  CombiFinder Plus  Manuel en pdf  Funding Calendar User Guide  BIP n°23    Global Door Controls KH-1410-1-US15 Instructions / Assembly  

Copyright © All rights reserved.
Failed to retrieve file