Home
Level Q7 User Manual ver 1
Contents
1. LEVEL DMX Channel Values Functions VERSION 1 9 DMX Channels Specifications are subject to change without any prior written notice ann FUNCTION L pamm 0 255 Red 0 Black 255 100 Red CREEN All LEDs n M 0 Black 255 100 Green BLUE All LEDs DE Blue 0 Black 255 100 Blue LL All LEDs White 0 Black 255 100 White COLOR CORRECTION 0 Function 1255 255 1 2 700k 255 7 200 COLOR MACROS 3 3 30 LEVEL Q7 User Manual Version 1 EtATION www elationlighting com ELATION LEVEL Q7 DMX Channel Values Functions VERSION 1 9 DMX Channels DMX Channel Functions Values MODE CHANNEL VALUE FUNCTION 415 7 9 Ji 6 s O O CHASE mACROS 0 SHUTTER STROBE DIMMER INTENSITY Intensity O to 100 31 LEVEL Q7 User Manual Version 1 www elationlighting com CLEANING AND MAINTENANCE CAUTION Disconnect from mains before starting maintenance operation CLEANING Frequent cleaning is recommended to insure proper function and an extended life e Clean LED lens surface weekly to avoid dust accumulation e Never use alcohol or solvents MAINTENANCE Regular inspections are recommended to insure proper function and an extended life There are no user serviceable parts inside th
2. 31 45 546 85 96 fax www elationlighting eu info elationlighting eu DOCUMENT VERSION 3 Please check www elationlighting com for the latest revision update of this manual DMX Document Software Channel Modes Version Version 2013 4151719 initial release 2 LEVEL Q7 User Manual Version 1 www elationlighting com CONTENTS General Information Warranty oafety Instructions General Guidelines Fixture Overview Mounting and Installation Understanding DMX Fixture Menu 3 LEVEL Q7 User Manual Version 1 www elationlighting com GENERAL INFORMATION INTRODUCTION Congratulations you have just purchased one of the most innovative and reliable lighting fixtures on the market today LEVEL Q7 has been designed to perform reliably for years when the guidelines in this booklet are followed Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this unit These instructions contain important information regarding safety during use and maintenance UNPACKING Thank you for purchasing the LEVEL Q7 by Elation Professional Every LEVEL Q7 has been thoroughly tested and has been shipped in perfect operating condition Carefully check the shipping carton for damage that may have occurred during shipping If the carton appears to be damaged carefully inspect your unit for damage and be sure all accessories necessary to operate the unit
3. ELATION LEVEL Q7 M User manual AN NOILV 13 EtATION www elationlighting com 02013 ELATION PROFESSIONAL all rights reserved Information specifications diagrams images and instructions herein are subject to change without notice ELATION PROFESSIONAL logo and identifying product names and numbers herein are trademarks of ELATION PROFESSIONAL Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged All non ELATION brands and product names are trademarks or registered trademarks of their respective companies ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and operation of this product Elation Professional USA 6122 S Eastern Ave Los Angeles CA 90040 323 582 3322 323 832 9142 fax www elationlighting com info elationlighting com Elation Professional B V Junostraat 2 6468 EW Kerkrade Netherlands 31 45 546 85 66
4. accompany return authorization R A number The R A number must be clearly written on the outside of the return package A brief description of the problem as well as the R A number must also be written down on a piece of paper and included in the shipping container If the unit is under warranty you must provide a copy of your proof of purchase invoice Items returned without R A number clearly marked on the outside of the package wil be refused and returned at customer s expense You may obtain a R A number by contacting customer support at 323 582 3322 35 IMPORTANT NOTICE There are no user serviceable parts inside this unit Do not attempt any repairs yourself doing so will void your manufactures warranty Damages resulting from modifications to this fixture and or the disregard of safety and general user instructions found in this user manual void the manufactures warranty and are not subject fo any warranty claims and or repairs 5 LEVEL Q7 User Manual Version 1 ELATION www elationlighting com 2 YEAR LIMITED WARRANTY A Elation Professional amp hereby warrants to the original purchaser Elation Professional amp products to be free of manufacturing defects in material and workmanship for a period of two years 730 days from the date of purchase This warranty shall be valid only if the product is purchased within the United States of America including possessions and territories It is the owner s responsibil
5. at its expense and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship sole responsibility of Elation Professional amp under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of Elation Professional amp products covered by this warranty were manufactured after January 1 1990 and bare identifying marks to that effect E Elation Professional amp reserves the right to make changes in design and or improvements upon its products without any obligation to include these changes in any products theretofore manufactured F No warranty whether expressed or implied is given or made with respect to any accessory supplied with products described above Except to the extent prohibited by applicable law all implied warranties made by Elation Professional amp in connection with this product including warranties of merchantability or fitness are limited in duration to the warranty period set forth above And no warranties whether expressed or implied including warranties of merchantability or fitness shall apply to this product after said period has expired The consumer s and or Dealer s sole remedy shall be such repair or replacement as is expressly provided above and under no circumstances shall Elation Professional amp be liable for any loss or damage direct or consequential arising out of the us
6. have arrived intact In the event damage has been found or parts are missing please contact our customer support team for further instructions Please do not return this unit to your dealer without first contacting customer support at the number listed below Please do not discard the shipping carton in the trash Please recycle whenever possible BOX CONTENTS 1 powerCON Power Cable 1 5pin DMX Cable 1 Safety Cable 1 Gel Frame Gel Frame Holder and Frost Filter Gel e Manual 8 Warranty Card 4 LEVEL Q7 User Manual Version 1 www elationlighting com CUSTOMER SUPPORT Elation Professionale provides a customer support line fo provide set up help and to answer any question should you encounter problems during your set up or initial operation You may also visit us on the web at www elationlighting com for any comments or suggestions For service related issue please contact Elation Professional ELATION SERVICE USA Monday Friday 8 00am to 5 00pm PST Voice 323 582 3322 Fax 323 832 9142 E mail support elationlighting com ELATION SERVICE EUROPE Monday Friday 08 30 to 17 00 CET Voice 31 45 546 85 30 Fax 31 45 546 85 96 E mail support elationlighting eu WARRANTY REGISTRATION The LEVEL Q7 carries a two year 730 days limited warranty Please fill out the enclosed warranty card to validate your purchase All returned service items whether under warranty or not must be freight pre paid and
7. inserted completely into the DMX input jack of the fixture The DMX controller is switched off or defective DMX cable or connector is defective DMX terminator has been inserted into the last fixture in your DMX chain 16 LEVEL Q7 User Manual Version 1 www elationlighting com FIXTURE MENU ON BOARD SYSTEM MENU The LEVEL Q7 comes with an easy to navigate system menu The next section will detail the functions of each command in the system menu LED CONTROL PANEL The LEVEL Q7 control panel see image below located on back of the fixture offers several features to select from such as setting the DMX address running pre programmed macros changing display options and resetting the fixture to factory defaults There are 4 buttons which are explained below MODE ESC Press this button to enter the fixture menus and to return to the previous menu The display will automatically exit the fixture menus in 10 seconds from the last button press UP DOWN Press these buttons to navigate through the different menu functions and access sub menu sections ENTER Press this button to select a menu item and press again to confirm your selection 17 LEVEL Q7 User Manual Version 1 LEVEL Q7 SYSTEM MENU VERSION 1 www elationlighting com Default Settings Shaded FUNCMODE PERSNAL MANCNTRL MODE SET Address ValuDisp SetSlave Auto Program Soft Ver Stat Set 001 509 A
8. the Enter button to confirm Press the MODE ESC button in order to return to the main menu 4 Program selection for Edit Program e Select Edit program by turning the encoder Press the Enter button to confirm e Select Edit program by turning the encoder Press the Enter button to confirm Turn the encoder to select the desired program With this function you can edit specific scenes into a specific program Press the Enter button to confirm Press the MODE ESC button in order to return to the main menu 5 Automatic Scene Recording e Select Edit program by turning the encoder Press the Enter button to confirm Select Edit scenes by turning the encoder Turn the encoder to select the desired scene numbers you can program a max number of 250 Press the Enter button to confirm Press the MODE ESC button in order to return to the main menu 28 LEVEL Q7 User Manual Version 1 www elationlighting com EditProg RecCntrl Execution continued Example Program 2 includes scenes 10 11 12 13 Program 4 includes scenes 8 9 10 Program 6 includes scenes 12 13 14 15 Auto Pro Part 1 is Program 2 Auto Pro Part 2 is Program 3 Auto Pro Part 3 is Program 6 The 3 Slave groups run the Auto Program in certain time segments as shown in the following picture 29 LEVEL Q7 User Manual Version 1 EtATION www elationlighting com DMX CHANNEL FUNCTIONS AND VALUES
9. under Edit Prog and edit the individual scenes under Edit Scen 1 2 3 4 5 Access the main menu by pressing MODE ESC Press the UP DOWN buttons until FuncMode is displayed and press ENTER Press the UP DOWN buttons until AutoProg is displayed and press ENTER Press the UP DOWN buttons to select desired value Master Alone Press ENTER to confirm selection Info Timelnfo Cur Time Display the run time of the fixture from the last power ON The counter is reset after turning the device off 1 2 3 4 Access the main menu by pressing MODE ESC Press the UP DOWN buttons until Info 2 is displayed and press ENTER Press the UP DOWN buttons until Timelnfo is displayed and press ENTER Press the UP DOWN buttons until Cur Time is displayed and press ENTER and the display will show XXXh hours Press MODE ESC to return to previous menu or display will automatically exit 20 LEVEL Q7 User Manual Version 1 www elationlighting com Info Timelnfo TotalHrs Display the total running time of the fixture 1 Access the main menu by pressing MODE ESC 2 Press the UP DOWN buttons until Info is displayed and press ENTER 3 Press the UP DOWN buttons until Timelnfo is displayed and press ENTER 4 Press the UP DOWN buttons until TotalHrs is displayed and press ENTER and the display will show XXXXXh hours o Press MODE ESC to return to prev
10. 0m 2 5m 5m 7 5 m 0 ft 8 2 ft 16 4 ft 24 6 ft 7 Beam Angle 0 32m 1 0ff 20 62m 0208 0092 03 08 13 Field Ange 00 57 01 98 0112 03 78 01 66 05 48 DIMENSIONAL DRAWINGS 55 140 5mm od 278 6mm 53 8 7 133 5mm 222 0mm pe one N ae a taal 7 6 193 0mm 10 2 260 0 wear lao DE 1 Please Note Specifications improvements in the design of this unit and this manual are subject to change without any prior written notice 34 LEVEL Q7 User Manual Version 1 13 Field Angle ELATION www elationlighting com CIRCUIT SCHEMATIC LJBO188 0 A THERMAL ZPNGOR TERMINAL BLOCK E laj SUPPLY m POWER SUPPLY Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice 35 LEVEL Q7 User Manual Version 1 www elationlighting com OPTIONAL ACCESSORIES ORDER CODE ITEM ACSPDMXSOPRO 50 ft 15m PRO DMX Cable Model LEVEL 70 CONFORMS TO UL STD 1598 CERTIFIED TO CSA STD C22 2 NO 250 0 100 240V 50 60Hz 120W MAX C US MANUFACTURING DATE WARNING a te rt e K Dry Locations Only 3104374 Pour Emplacements Secs Seulemen 36 LEVEL Q7 User Manual Version 1
11. 4 Open 5 Open Be sure to follow the above figure when making your own cables Do not use the ground lug on the XLR connector Do not connect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR outer casing Grounding the shield could cause a short circuit and erratic behavior DMX 512 CONTROLLER CONNECTION Connect the provided XLR cable to the female XLR output of your controller and the other side to the male XLR input of the LEVEL Q7 Please refer to the diagram below You can chain multiple panels together through serial linking The cable that should be used is two conductor shielded DMX cable with XLR input and output connectors Always be sure daisy chain your in and out data connections never split or Y your DMX connections unless you are using an approved DMX splitter such as the Elation Opto Branch 4 or DMX 41 DMX512 gt DMX controller Tw 120 Ohms DMX 512 CONNECTION WITH DMX TERMINATOR A DMX terminator should be used in all DMX lines especially in longer runs The use of a terminator may avoid erratic behavior in your DMX line A terminator is a 120 ohm 1 4 watt resistor that is connected between pins 2 and 3 of a male XLR connector DATA and DATA This fixture is inserted in the female XLR connector of the last fixture in your daisy chain to terminate the line Using a ine terminator Elation part DMX T PACK will decrease th
12. R to confirm selection Press MODE ESC to return to previous menu or display will automatically exit EditProg EditProg Edit the internal programs 1 2 3 4 Access the main menu by pressing MODE ESC Press the UP DOWN buttons until EditProg is displayed and press ENTER Press UP DOWN buttons until EditProg is displayed and press ENTER Press UP DOWN buttons to select desired Program number Prog 1 Prog 2 Prog 3 Prog 4 Prog 5 Prog 6 Prog 7 Prog 8 Prog 9 Prog 10 and press ENTER to confirm selection Press UP DOWN buttons to select desired Program number Prog 1 Prog 2 Prog 3 Prog 4 Prog 5 Prog 6 Prog 7 Prog 8 Prog 9 Prog 10 and press ENTER to confirm selection Press UP DOWN buttons to select internal program test or step to edit ProgTest EdStep01 EdStep64 and press ENTER to confirm selection Press UP DOWN buttons to select desired scene SxxSC001 Sxx C250 xx 01 64 and press ENTER to confirm selection Press MODE ESC to return to previous menu or display will automatically exit 26 LEVEL Q7 User Manual Version 1 www elationlighting com EditProg EditScen Edit the scenes of the internal programs 1 Access the main menu by pressing MODE ESC 2 Press the UP DOWN buttons until EditProg is displayed and press ENTER 3 Press UP DOWN buttons until EditScen is displayed and press ENTER 4 Press UP DOWN buttons to select desired Scene nu
13. X Recorder FuncMode Address Adjust the desired DMX address via the Control Board 1 Access the main menu by pressing MODE ESC 2 Press the UP DOWN buttons until FuncMode is displayed and press ENTER 3 Press the UP DOWN buttons until Address is displayed and press ENTER 4 Press the UP DOWN buttons to select desired DMX address 5 Press ENTER to confirm selection FuncMode ValuDisp Display the DMX 512 value of each channel 1 Access the main menu by pressing MODE ESC 2 Press the UP DOWN buttons until FuncMode is displayed and press ENTER 3 Press the UP DOWN buttons until ValuDisp is displayed and press ENTER 4 Press the UP DOWN buttons to select desired value All Ch Auto Red Gree Blue Whit Stro Dimm Macr Temp Press ENTER to confirm selection 19 LEVEL Q7 User Manual Version 1 www elationlighting com FuncMode SetSlave Define the fixture as slave 1 2 3 4 5 Access the main menu by pressing MODE ESC Press the UP DOWN buttons until FuncMode is displayed and press ENTER Press the UP DOWN buttons until SetSlave is displayed and press ENTER Press the UP DOWN buttons to select desired value Slave 1 Slave 2 Slave 3 Press ENTER to confirm selection FuncMode AutoProg Define the fixture mode Master Alone for running Auto Programs Select the desired internal programs under Sel Prog set the number of steps
14. and exit the current command UP Button Used to toggle forward through the menu functions and settings DOWN Button Used to toggle down or back through the menu functions and settings eS dee eS ENTER Button Used to enter into or lock a certain menu function 10 5 Pin DMX OUT Provides outgoing DMX signal via a female 5 pin XLR jack 11 Power OUT Power connection to daisy chain to another unit 9 LEVEL Q7 User Manual Version 1 www elationlighting com MOUNTING AND INSTALLATION CAUTION Please consider the GB7000 15 EN60598 2 17 and the other respective national norms during the installation The installation must only be carried out by a qualified person CAUTION T he electric connection mustonly be carried out by a qualified electrician EI CAUTIONS he recommended temperature for this fixture is 13 F to 113 F 25 C to 45 C Do not use the fixture under or above this temperature e For added protection mount the fixture in areas outside walking paths seating areas or in areas were unauthorized personnel might reach the fixture Before mounting the fixture to any surface make sure the installation area can hold a minimum point load of 10 times the weight of the fixture 90 Ibs 40 kgs Fixture installation must always be secured with a secondary safety attachment such as an appropriate safety cable e Never stand directly below the device when mounting removing
15. buttons to select desired value Auto Red Gree Blue Whit Stro Dimm Macr Temp and press ENTER to confirm selection 4 Press UP DOWN buttons to select desired value 000 255 and press ENTER to confirm selection o Press MODE ESC to return to previous menu or display will automatically exit Mode Set UserMode Select the DMX channel mode 4CH 5CH 7CH 9CH default is ACH 1 Access the main menu by pressing MODE ESC 2 Press the UP DOWN buttons until Mode Set is displayed and press ENTER and press ENTER again and UserMode will display 3 Press UP DOWN buttons to select desired value 4CH 5CH 7CH 9CH press ENTER to confirm selection 4 Press MODE ESC to return to previous menu or display will automatically exit 25 LEVEL Q7 User Manual Version 1 www elationlighting com EditProg Sel Prog select Auto Programs defaults ProPart1 Prog 1 ProPart2 Prog 2 ProPart3 Prog 3 1 2 3 4 6 Access the main menu by pressing MODE ESC Press the UP DOWN buttons until EditProg is displayed and press ENTER Press UP DOWN buttons until Sel Prog is displayed and press ENTER Press UP DOWN buttons to select desired Auto Program Part ProPart1 ProPart2 ProPart3 and press ENTER to confirm selection Press UP DOWN buttons to select desired Program number Prog 1 Prog 2 Prog 3 Prog 4 Prog 5 Prog 6 Prog 7 Prog 8 Prog 9 Prog 10 and press ENTE
16. com M Ae 7 M NN 54 1 Mounting Bracket Stand included 2 Clamp optional 3 Safety Cable included INSTALLATION VIA MOUNTING BRACKET STAND Attach a clamp to center 13 hole on the Mounting Bracket using an M12 screw Pull provided Safety Cable through mounting bracker and over the trussing system or a safe installation I3 This step is a very important to ensure the fixture will not drop if the clamp fails 12 LEVEL Q7 User Manual Version 1 www elationlighting com UNDERSTANDING DMX DMX 512 DMX is short for Digital Multiplex This is a universal protocol used by most lighting and controller manufactures as a form of communication between intelligent fixtures and controllers DMX allows all makes and models of different manufactures to be linked together and operate from a single controller This is possible as long as all the fixtures and the controller are DMX compliant A DMX controller sends the DMX data instructions to the fixture allowing the user to control the different aspects of an intelligent light DMX data is sent out as serial data that travels from fixture to fixture via data IN and data OUT XLR terminals located on the fixtures most controllers will only have output jacks DMX LINKING To ensure proper DMX data transmission always use proper DMX cables and a terminator When using several DMX fixtures try to use the shortest cable path possible Never spl
17. e of or inability to use this product G This warranty is the only written warranty applicable to Elation Professional amp Products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published 6 LEVEL Q7 User Manual Version 1 ELATION www elationlighting com SAFETY INSTRUCTIONS The LEVEL Q7 is an extremely sophisticated piece of electronic equipment To guarantee a smooth operation it is important to follow the guidelines in this manual The manufacturer of this device will not accept responsibility for damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual This device falls under PROTECTION CLASS 1 It s essential this device is grounded properly and only qualified personnel perform all electrical connections CAUTION Never touch the device during operation The housing may heat up CAUTION Never look directly into the light source as sensitive persons may suffer an epileptic shock CAUTION Keep this device away from rain and moisture CAUTION Unplug mains lead before opening the housing e For proper operation follow the Installation guidelines described in this manual Only qualified and certified personnel should perform installation of this fixture and only the original rigging parts brackets holders clamps safety cables included with this fixture should be used for installation A
18. e possibilities of erratic behavior 14 LEVEL Q7 User Manual Version 1 www elationlighting com 1200 Termination reduces signal errors and avoids signal transmission problems MI and interference It is always advisable to connect a DMX terminal Resistance 120 Ohm 1 4 W between PIN 2 DMX 3 DMX of the last fixture 5 Pin XLR DMX CONNECTORS Some manufactures use 5 pin XLR connectors for DATA transmission in place of 3 pin o pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard o pin XLR connectors in to a 3 pin line a cable adaptor must be used these adaptors are readily available at most electric stores The following chart details a proper cable conversion 3 Pin XLR to 5 Pin XLR Conversion Conductor 3 Pin XLR Female Out 5 Pin XLR Male In Data Compliment signal Pin 2 Data True signal Pin 3 Notused Pi4 DoNotUse Notused Pn5 DoNot Use 15 LEVEL Q7 User Manual Version 1 www elationlighting com DMX ADDRESSING All fixtures should be given a DMX starting address when using a DMX controller so the correct fixture responds to the correct control signal This digital starting address is the channel number from which the fixture starts to listen to the digital control information sent out from the DMX controller The allocation of this starting DMX address is achieved by setting the correct DMX address on the digital di
19. ge Life May vary depending on several factors including but not limited to Environmental Conditions Power Voltage Usage Patterns On Off Cycling Control and Dimming PHOTOMETRIC DATA 3636 LUX 388 FC Q16 4 SM EFFECTS Electronic Strobe and Varying Settings Color and Chase Macros Electronic Dimming 0 100 CONTROL CONNECTIONS 4 DMX Channel Modes 4 5 7 9 4 Button Control Panel LCD Menu Display 5pin DMX In Out powerCON In Out SIZE WEIGHT Length 11 0 278 6mm Width 5 5 140 5mm Vertical Height 10 2 260mm Weight 9 0 Ibs 4 kg ELECTRICAL THERMAL AC 100 240V 50 60Hz 127W Max Power Consumption Multiple Unit Power Linking 13 F to 113 F 25 C to 45 C APPROVALS RATINGS CE Approved cETLus Approved IP20 Rated INSTALLATION Rigging Integrated Dual Yoke Floor Stand Working Position Any 360 Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice 33 LEVEL Q7 User Manual Version 1 ELATION www elationlighting com PHOTOMETRIC DATA RED LEDs 190 FC 2046 LUX 43 FC 467 LUX 19 FC 200 LUX GREEN LEDs 596 FC 6420 LUX 145FC 1565LUX 64FC 693 LUX BLUE LEDs 88 FC 950 LUX 23 FC 249 LUX 10 FC 113 LUX WHITE LEDs 695 FC 7485 LUX 176FC 1890 LUX 79FC 850 LUX FULL ON 1366 FC 14 700 LUX 338 FC 3636LUX 149 FC 1601 LUX LUX x 0 0929 FC 7 Beam Angle
20. ious menu or display will automatically exit Info Timelnfo Last Hrs Display the last the running time of the fixture 1 Access the main menu by pressing MODE ESC 2 Press the UP DOWN buttons until Info is displayed and press ENTER 3 Press the UP DOWN buttons until Timelnfo is displayed and press ENTER 4 Press the UP DOWN buttons until Last Hrs is displayed and press ENTER and the display will show XXXXXh hours 5 Press MODE ESC to return to previous menu or display will automatically exit Info Timelnfo TimePass Enter the timer password 038 1 Access the main menu by pressing MODE ESC 2 Press the UP DOWN buttons until Info is displayed and press ENTER 3 Press the UP DOWN buttons until Timelnfo is displayed and press ENTER 4 Press the UP DOWN buttons until TlmePass is displayed and press ENTER and the display will show XXX Press UP DOWN buttons until 038 is displayed and press ENTER O Press MODE ESC to return to previous menu or display will automatically exit 21 LEVEL Q7 User Manual Version 1 www elationlighting com Info Timelnfo Clr Last Clear last run time of the fixture default is OFF 1 2 3 4 6 Access the main menu by pressing MODE ESC Press the UP DOWN buttons until Info is displayed and press ENTER Press the UP DOWN buttons until Timelnfo is displayed and press ENTER Press the UP DOWN bu
21. is fixture please refer all other service issues to an authorized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points during routine inspections Adetailed electric check by an approved electrical engineer every three months to make sure the circuit contacts are in good condition and prevent overheating Be sure all screws and fasteners are securely tightened at all times Lose screws may fall out during normal operation resulting in damage or injury as larger parts could fall Check for any deformations on the housing color lenses rigging hardware and rigging points ceiling suspension trussing Deformations in the housing could allow for dust to enter into the fixture Damaged rigging points or unsecured rigging could cause the fixture to fall and seriously injure a person s Electric power supply cables must not show any damage material fatigue or sediments Never remove the ground prong from the power cable 32 LEVEL Q7 User Manual Version 1 ELATION www elationlighting com TECHNICAL SPECIFICATIONS FEATURES 7 Beam 13 Field Angles 2 00K 7 200K Color Correction Flicker Free Operation for TV and FILM Rugged Die Cast Aluminum Exterior Rubber Padded Base with Dual Yoke Floor Stand Multiple Unit Power Linking Gel Frame and Holder Included SOURCE 7 15W QUAD Color RGBW LEDs 100 000 Hour Avera
22. it a DMX line with a Y style connector The order in which the fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned a starting DMX address of 1 may be placed anywhere in the DMX chain at the beginning at the end or anywhere in the middle The DMX controller knows to send data assigned to address 1 to that fixture no matter where it is located in the DMX chain The DMX address is set electronically using the controls on the LCD menu DATA CABLE DMX Cable REQUIREMENTS For DMX and Master Slave Operation Your fixture and your DMX controller require a standard 3 pin or 5 pin XLR connector for data input and data output see figure below If you are making your own cables be sure to use two conductor shielded digital DMX cable rated at 120 ohms this cable is designed for DMX transmission and may be purchased from your Elation dealer or at most professional lighting retailers Your cables should be made with a male and female XLR connector on either end of the cable Also remember that a DMX line must be daisy chained and cannot be split unless using an approved DMX splitter such as the Elation Opto Branch 4 or DMX 4 7 13 LEVEL Q7 User Manual Version 1 www elationlighting com DMX Output DMX Input DMX Output DMX Input 3 Pin XLR Socket 3 Pin XLR Socket 5 Pin XLR Socket 5 Pin XLR Socket Ground 1 Ground 2 Data 2 Data o e 3 Data 3 Data
23. ity to establish the date and place of purchase by acceptable evidence at the time service is sought B For warranty service send the product only to the Elation Professional factory All shipping charges must be pre paid If the requested repairs or service including parts replacement are within the terms of this warranty Elation Professional amp will pay return shipping charges only to a designated point within the United States If the entire instrument is sent it must be shipped in its original package No accessories should be shipped with the product If any accessories are shipped with the product Elation Professional amp shall have no liability what so ever for loss of or damage to any such accessories nor for the safe return thereof C This warranty is void if the serial number has been altered or removed if the product is modified in any manner which Elation Professional amp concludes after inspection affects the reliability of the product if the product has been repaired or serviced by anyone other than the Elation Professional amp factory unless prior written authorization was issued to purchaser by Elation Professional if the product is damaged because not properly maintained as set forth in the instruction manual D This is not a service contract and this warranty does not include maintenance cleaning or periodic check up During the period specified above Elation Professional amp will replace defective parts
24. mber Scen001 Scen250 and press ENTER to confirm selection 5 Press UP DOWN buttons to select desired function Auto Red Gree Blue Whit Stro Dimm Macr Temp ScenTime InByOut and press ENTER to confirm selection 6 Press UP DOWN buttons to select desired value 001 250 and press ENTER to confirm selection 7 Press MODE ESC to return to previous menu or display will automatically exit EditProg RecCntrl This fixture features an integrated DMX recorder by which you can transmit the programmed scenes from your DMX controller to the moving head Adjust the desired scene numbers via the encoder from to When you call up the scenes at your controller they will automatically be transmitted to the moving head EditProg RecCntrl Execution A Master unit can send up to 3 different data groups to the Slave units i e a Master unit can start 3 different Slave units which run 3 different programs The Master unit sends the 3 program parts in a continuous loop Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Part 1 Part 2 Part 3 Part 1 Part 2 Part 3 Part 1 Part 2 Part 3 The Slave unit receives data from the Master unit according to the group which the Slave unit was assigned to If e g a Slave unit is set to Slave 1 in the menu Set to Slave the Master unit sends Auto Program Part 1 to the Slave unit If set to Slave 2 the Slave unit receives Au
25. ny modifications will void the original manufactures warranty and increase the risk of damage and or personal injury e Never look directly into the light source of this fixture to prevent risk of injury to your retina which may induce blindness Those suffering from EPILEPSY should avoid looking directly into the light source of this unit at all times e The fan and air inlets must remain clean and never blocked Allow approx 6 15cm between this fixture and other devices or a wall for proper cooling e Always disconnect from main power source before performing any type of service and or cleaning procedure Only handle the power cord by the plug end never pull out the plug by tugging the wire portion of the cord e Do not operate this fixture if the power cord has become frayed crimped and or damaged If the power cord is damaged replace it immediately with a new one of similar power rating 7 LEVEL Q7 User Manual Version 1 www elationlighting com GENERAL GUIDELINES NEVER OPEN THIS FIXTURE WHILE IN USE During the initial operation of this fixture a light smoke or smell may emit from the interior of the fixture This is a normal process and is caused by excess paint in the interior of the casing burning off from the heat associated with the lamp and will decrease gradually over time This fixture is a professional lighting effect designed for use on stage in nightclubs theatres etc Do not attempt installation and or ope
26. oller default is ON 1 2 3 4 6 Access the main menu by pressing MODE ESC Press the UP DOWN buttons until Persnal is displayed and press ENTER Press the UP DOWN buttons until Stat Set is displayed and press ENTER Press the UP DOWN buttons until Addr DMX is displayed and press ENTER and the display will show OFF ON Press the UP DOWN buttons to select OFF or ON and press ENTER Press MODE ESC to return to previous menu or display will automatically exit Persnal Stat Set NoDMXSta Fixture runs in Auto Run if no DMX signal is detected Options include Hold Auto CloShut default is Hold 1 2 3 4 5 6 Access the main menu by pressing MODE ESC Press the UP DOWN buttons until Persnal is displayed and press ENTER Press the UP DOWN buttons until Stat Set is displayed and press ENTER Press the UP DOWN buttons until NoDMXSta is displayed and press ENTER Press the UP DOWN buttons to select desired value Hold Auto CloShut and press ENTER to confirm selection Press MODE ESC to return to previous menu or display will automatically exit Persnal Disp Set Off Time Shut off the LED display after 02 to 59 minutes default is 05 minutes 1 2 3 4 5 Access the main menu by pressing MODE ESC Press the UP DOWN buttons until Persnal is displayed and press ENTER Press the UP DOWN buttons until Disp Set is displayed and press ENTER Pre
27. or servicing the fixture 10 LEVEL Q7 User Manual Version 1 www elationlighting com MOUNTING POINTS Overhead mounting requires extensive experience including amongst others calculating working load limits installation material being used and periodic safety inspection of all installation material and the device If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury Fixture is fully operational in any mounting position hanging upside down side mounted or on any flat level surface and will remain steady no matter the angle of the fixture head e Be sure the fixture is kept at least 0 5m 1 5 feet away from any flammable materials decoration etc SS SE S NS MA XZ ND aN A A TA A EEE EES GRE 1 Jr Me PLU S AA pann A 592 c L Se 2 DA i da c Ze Ww 2 KA 22 Q L DA LS SS 2 SET CNW SY ail Ss 5 gt C D a gt Na Z E ww Z SS C rs Ww Z a TC o s Lt ae CHE gt 52 a AI REN Red SS 222 S 2 di c pS Xx A 11 LEVEL Q7 User Manual Version 1 www elationlighting
28. ration without proper knowledge of how to do so Do not permit operation by persons who are not qualified for operating this type of theatrical fixture Most damages are the result of operations by nonprofessionals Consistent operational breaks may ensure the fixture will function properly for many years to come Do not shake fixture avoid brute force when installing and or operating the device Always install the fixture with an appropriate safety cable When installing the fixture in a suspended environment always use mounting hardware that is no less than M10 x 25 mm also be sure the hardware is insert in the pre arranged screw holes in the base of the fixture Please use the original packaging and materials to transport the fixture in for service 8 LEVEL Q7 User Manual Version 1 www elationlighting com FIXTURE OVERVIEW mh LED Lens Assembly Mounting Bracket Stand 5 Pin DMX IN Power IN LED Menu Control Display MODE ESC Button UP Button DOWN Button O A N ENTER Button 10 5 Pin DMX OUT 11 Power OUT 49 LED Lens Assembly 7 RGBW Quad LEDs comprise the LED assembly Mounting Bracket Stand Used to mount fixture 5 Pin DMX IN Accepts incoming DMX signal via a male 5 pin XLR jack Power IN Power connection powerCON to power source LED Menu Control Display Fixture menu display MODE ESC Button Used to access the menu functions
29. splay located on the back of the fixture You can set the same starting address for all fixtures or a group of fixtures or set different address for each individual fixture Be advised that setting all fixtures to the same DMX address will subsequently control all fixtures in the same fashion in other words changing the settings of one channel will affect all the fixtures simultaneously If you set each fixture to a different DMX address each unit will start to listen to the channel number you have set based on the quantity of control channels DMX channels of each fixture That means changing the settings of one channel will only affect the selected fixture In the case of the LEVEL Q7 when in 9 Channel Mode can also be set to 4 5 or 7 you should set the starting DMX address of the first unit to 1 the second unit to 10 1 9 the third unit to 19 10 9 the fourth unit to 28 19 9 and so on Note During start up the LEVEL Q7 will automatically detect whether a DMX data signal is being received or not If DMX data signal is being received the display will show AddrzXXX XXX representing the actual DMX address If the fixture is not receiving a DMX signal the display will flash If your fixture is connected to a DMX controller and the display is flashing not receiving a DMX signal please check the following The 3 PIN or 5 PIN XLR input plug cable with DMX signal from controller is not connected or is not
30. ss the UP DOWN buttons until Off Time is displayed and press ENTER Press the UP DOWN buttons to select desired value OFF 02 59 and press ENTER to confirm selection Press MODE ESC to return to previous menu or display will automatically exit 23 LEVEL Q7 User Manual Version 1 www elationlighting com Persnal Disp Set Key Lock Lock the Control Panel buttons automatically after exiting main menu for 15 seconds Unlock by keeping the MODE ESC button pressed for 3 seconds Default is OFF 1 2 3 4 5 Access the main menu by pressing MODE ESC Press the UP DOWN buttons until Persnal is displayed and press ENTER Press the UP DOWN buttons until Disp Set is displayed and press ENTER Press the UP DOWN buttons until Key Lock is displayed and press ENTER Press the UP DOWN buttons to select desired value OFF ON and press ENTER to confirm selection Press MODE ESC to return to previous menu or display will automatically exit Persnal Temp C F Display the temperature in Celsius or Fahren default is Fahren 1 2 3 4 Access the main menu by pressing MODE ESC Press the UP DOWN buttons until Persnal is displayed and press ENTER Press the UP DOWN buttons until Temp C F is displayed and press ENTER Press the UP DOWN buttons to select desired value Fahren Cels and press ENTER to confirm selection Press MODE ESC to return to previous menu or display will a
31. to Program Part 2 27 LEVEL Q7 User Manual Version 1 www elationlighting com EditProg RecCntrl Execution continued To start a Auto Program please proceed as follows 1 Slave Setting e Select Function Mode by turning the encoder Press the Enter button to confirm e Select Set to slave by turning the encoder Press the Enter button to confirm Turn the encoder to select Slave 1 Slave 2 or Slave 3 Press the Enter button to confirm Press the MODE ESC button in order to return to the main menu 2 Automatic Program Run e Select Function Mode by turning the encoder Press the Enter button to confirm e Select Auto Program by turning the encoder Press the Enter button to confirm e Turn the encoder to select Master or Alone The selection Alone means Stand Alone mode and Master that the device is defined as master Press the Enter button to confirm Press the MODE ESC button in order to return to the main menu 3 Program selection for Auto Pro Part e Select Edit program by turning the encoder Press the Enter button to confirm e Select Select programs by turning the encoder Press the Enter button to confirm e Turn the encoder to select Auto Pro Part 1 Auto Pro Part 2 or Auto Pro Part 3 and thus select which Slave program is to be sent Selection Part 1 means that the Slave unit runs the same program as the master units Press
32. ttons until Last is displayed and press ENTER and the display will show OFF ON Press the UP DOWN buttons to select OFF or and press ENTER to clear last run time NOTE A correct password must be entered in the TimePass menu order to clear last run time Press MODE ESC to return to previous menu or display will automatically exit Info Tempinfo HeadTemp Display the temperature of the fixture default is Fahrenheit 1 2 D 4 5 Access the main menu by pressing MODE ESC Press the UP DOWN buttons until Info is displayed and press ENTER Press the UP DOWN buttons until Templnfo is displayed and press ENTER Press the UP DOWN buttons until HeadTemp is displayed and press ENTER and the display will show XXXF degrees C F Press MODE ESC to return to previous menu or display will automatically exit Info Soft Ver Display the software version of the fixture 1 2 Je Access the main menu by pressing MODE ESC Press the UP DOWN buttons until Info is displayed and press ENTER Press the UP DOWN buttons until Soft Ver is displayed and press ENTER and the display will show VX X software version Press MODE ESC to return to previous menu or display will automatically exit 22 LEVEL Q7 User Manual Version 1 www elationlighting com Persnal Stat Set Addr DMX Adjust the desired DMX address via an external contr
33. uto Red Slave1 Slave2 Slave3 Master Alone Cur Time TotalHrs Last Hrs TimerPass Last Addr DMX NoDMXSta XXXX Hours XXXX Hours XXXX Hours Password XXX ON OFF Templnfo HeadTemp XXX C F Temperature In The Head ON OFF CloShut Hold Auto DMX Address Setting DMX Value Display Slave Setting Auto Program Power On Running Time Fixture Running Time Fixture Last Times Clear Timer Password 038 Clear Fixture Last Time LPs Version LE Each IC Address Via DMX Auto Run If No DMX Off Time Display Shut Off Time Disp Set Key Lock ON OFF Key Lock Celsius Temperature switch Temp C F Fahren Between C or Man Hold ON OFF Manual Hold ResetDef ON OFF Restore Factory Settings ManCntrl Auto Red Gree Blue Whit Dimm Macr 4CH Mode Mode Mode 9CH Mode Stro Temp 18 Auto XXX Temp XXX LED Fine Adjustment Select DMX Channel Modes LEVEL Q7 User Manual Version 1 www elationlighting com ProPart1 Prog 1 10 SelProg ProPart2 Prog 1 10 ProPart3 Prog 1 10 Select Programs To Be Run Prog 1 ProgTest 015 Testing Program EditProg EdStepO01 5015 Program In Loop EDITPROG Prog 10 EdStep64 5645 Save And Exit Auto xxx Save And Automatically Scen 001 Edit Scen ScenTime Red xxx Return Scen 250 InByOut Manual Scenes Edit Automatic Scenes RecCntrl XX X
34. utomatically exit Persnal Man Hold Manual Hold 1 2 Bi 4 Access the main menu by pressing MODE ESC Press the UP DOWN buttons until Persnal is displayed and press ENTER Press the UP DOWN buttons until Man Hold is displayed and press ENTER Press the UP DOWN buttons to select desired value OFF ON and press ENTER to confirm selection Press MODE ESC to return to previous menu or display will automatically exit 24 LEVEL Q7 User Manual Version 1 www elationlighting com Persnal ResetDef Restore factory settings function ON or OFF the default is OFF 1 Access the main menu by pressing MODE ESC 2 Press the UP DOWN buttons until Persnal is displayed and press ENTER 3 Press the UP DOWN buttons until is displayed and press ENTER 4 Press the UP DOWN buttons to select desired value OFF ON and press ENTER to confirm selection o Press MODE ESC to return to previous menu or display will automatically exit ManCntrl ManCntri Fine adjustment of all LEDs All effects will be canceled and the shutter opens and the dimmer intensity will be set to 100 9o Focus the light on a flat surface or wall and perform the fine adjustments using individual the functions Auto Red Gree Blue Whit Stro Dimm Macr Temp 1 Access the main menu by pressing MODE ESC 2 Press the UP DOWN buttons until ManCntrl is displayed and press ENTER 3 Press the UP DOWN
Download Pdf Manuals
Related Search
Related Contents
PDFダウンロード(200KB) - 菱電工機エンジニアリング株式会社 TAFCO WINDOWS NU2-387S-I Installation Guide Kit de adaptadores AV2 Powerline 1200 TM-096 GR ョ ラウンジタッション グリーン 取扱説明 書 Verー TritonNav User Manual Sunbeam Bedding SBRTUS1 User's Manual Harbor Freight Tools 4 in. Swivel Vise with Anvil Product manual Frigidaire FGMV175QF Product Specifications Sheet Ide Line 740-108 User's Manual Cisco 24-Port 10/100 Ethernet Switch Copyright © All rights reserved.
Failed to retrieve file