Home

Users manual

image

Contents

1. He 36 Figure 10 1 Dimensions of the T08 ExCam IPQ1755 with K1 flange 39 Figure 10 2 Dimensions of the T08 ExCam IPQ1755 with K2 flange 40 Figure 10 3 Dimensions of the T08 ExCam IPQ1755 accessories 41 Doc ID 141023 PTO8BA TG ExCam IPQ1755 series en rev 01 Seite von 44 Revision history VICON k GmbH Product T08 ExCam IPQ1755 Title User manual ExCam IPQ1755 type 08 Doc Id 141023 PTO8BA TG ExCam IPQ1755 series en 01 Author Thiemo Gruber Date October 23 2014 Rev Index Datum Name Bemerkung Freigabe EX Beauftragter 0 October 23 2014 T Gruber Compilation of the document Reviewed and approved October xx 2014 S Seibert 1 December 05 2014 S Seibert Revision and approval Reviewed and approved December 05 2014 S Seibert Doc ID 141023 PT08BA TG ExCam IPQ1755 series en rev 01 Seite 4 von 44 9 c GmbH 1 Introduction The ExCam IPQ1755 is a camera type 08 manufactured by SAMCON Prozessleittech nik GmbH equipped with a light sensitive motor zoom and fast autofocus Due to the high performance of the ExCam IPQ1755 it disposes of a broad application spectrum within the industrial process observation or in the security sector regarding the surveil lance of personnel as well as machine operations Because of to the combination of a high reso
2. Backlight comp Off IR cut filter Off Auto Brightness Reset Close panel Figuer 6 9 Advanced control functions of the ExCam IPQ1755 IP 1354 IP 1355 IP1357 IPQ1755 Motor zoom 10x optical M37 x Varifokal IR korrigiert CS mount 0 75 connecting thread DC iris F1 2 2 8 P lis F1 2 P Iris F1 2 8 2 8 8mm 2 8 8 a Lens i i f5 1 51 mm Aspherical No No No No technology Focal distance 2 8 8 mm 2 8 8 mm 2 8 8 mm 5 1 51 mm Horizontal 100 wide 109 wide 92 wide 48 1 wide angle of view 34 tele 39 tele 2 5 1 tele Automatic Eee oh Day Night automatic operation Iris control automatic automatic MOD NL 0 30 m 0 10 m object distance Table 6 5 Lens data Information If not determined differently the default setting for the ExCam IPQ1755 is pre configured to reflect maximum sensor resolution HDTV 10801 q v chapter 3 6 and low compression high picture qual ity high network bandwidth Also the camera is set to wide range and the auto focus is deactivated If desired we customize the settings of the ExCam IPQ1755 to net ex isting network and hardware requirements Doc ID 141023 PTO8BA TG ExCam 1 1755 series en rev 01 Seite 26 von 44 Qs AMCON 6 4 1 Work preparation Attention Please carry out any preope
3. Attention Please observe the national regulations regarding security installa tion and accident prevention e g DIN EN 60079 14 as well as the safety guidelines described in this user manual and the EX installation manual Doc ID 141023 PT08BA TG ExCam IPQ1755 series en rev 01 Seite 18 von 44 Prozessleittechnik GmbH The ExCam IPQ1755 is delivered with an electrical connection cable type SKDxx Sys tem Kabel Digital and optional with an additional supply cable e g of the type Robust 210 The maximum cable length is 100 m depending on electromagnetic toler ance and can be determined individually to reflect the particular customer specifications The minimum cable length is 1 meter The ExCam IPQ1755 is manufactured with a pigtail reflecting the desired cable length Any electro technical work inside the camera s flameproof enclosure done by the user is prohibited Depending on the model option the ending of the camera s cable connection is either stripped to the blank Cu conductors or furnished with a plug 6 2 1 Potential equalization Figure 6 1 ExCam IPQ1755 potential equalization The potential equalization earthing of the camera housing is mandatory in order to avoid electrostatic charging and hence spark generation The screw terminal at the lower right hand side of the housing s rear side is intended for that purpose q v figure 6 1 The pro file of the potential equalization
4. Figure 6 3 ExCam IPQ1755 08 2 2 1 20 Figure 6 4 IPQ1755 08 2 2 1 21 Figure 6 5 ExCam IPQ1755 T08 VA2 2 K1 BOR B XXX P K L L 21 Table 6 2 Pin assignment SKDxx and plug contact 5 22 Figure 6 6 RJ45 Contact 23 Figure 6 7 Pin assighimeltss oae axe ex ee er ax dex ecce denne 23 Table 6 3 Pin assignment supply 24 Table 6 4 Status and control LED ie e tei He 25 Figure 6 8 Zoom and focus of the ExCam 1755 25 Abb 6 9 Advanced control functions of the ExCam 1755 26 GS Lens 26 Figure 6 10 Removing the protection roof 1 28 Figure 6 11 Removing the protection roof 2 28 Figure 6 12 Opening the ExCam 1 1755 29 Figure 6 13 ExCam IPQ1755 installation components 30 Figure 6 14 Bo ee nennen eenen 30 Figure 6 15 Control button 32 Figure 6 16 Status display ana ee pe en 32 Figure 7 1 Axis
5. 1 1755 series en rev 01 Seite 13 von 44 Housing material EN 10027 2 flameproof enclosure Additional housing materials Sight glass material Additional internal materials Weight without accessories Weight accessories Dimensions housing BxHxT Dimensions with accessories wxhxd Q Prozessle ACON GmbH Stainless steel MNo 1 4301 X5CrNi18 10 AISI 304 V2A Standard Stainless steel MNo 1 4305 X8CrNiS18 9 AISI 303 Standard Stainless steel MNo 1 4401 X5CrNiMo17 12 2 AISI 316 V4A optional Stainless steel MNo 1 4404 X2CrNiMo17 12 2 AISI 316L V4A optional Edelstahl MNo 1 4571 X6CrNiMoTi17 12 2 AISI 316Ti V4A optional Zinced spring steel MNo 1 0330 PTFE with glass microbeads GYLON Style 3504 blue silicone coating Silcoset 105 incl Cure Agent 28 VMQ silicone polyester acetone resistant titan Ti Borosilicate glass 10 1 420 Aluminum die cast zinced protection housing of the camera module polyamid isolatores mounting adapter made of aluminum AIMgSi zinced steel metal sheet plastics PUR etc 7100 g with K1 cable gland flange 8200 g with K2 cable gland flange 1600 g wall mount bracket and hood 113 0 mm x 138 5 mm x 260 2 mm K1 flange 113 0 mm x 138 5 mm x 276 0 mm K2 flange 135 0 mm x 238 0 mm x 413 0 mm The available stainless steel materials dispose of different specific charact
6. Microsoft Internet Explorer installing the AXIS Media Control AMC is required The installation request is executed during the initial commissioning In order to visualize the H 264 video streams QuickTime is recom mended For Motion JPEG coded video streams Java Applet is suggested which re quires JVM J2SE 1 5 or higher or JRE J2SE 5 0 or higher At delivery the ExCam IPQ1755 is set to the applicable net frequency 50Hz or 60Hz If the camera is used at a location with a differing net frequency a flickering of the picture might be noticeable particularly in surroundings with fluorescent tubes In such a case the applicable settings have to be carried out within the menu System Options gt Ad vanced gt Plain Config 7 1 Browser Support A list with the currently supported web browsers operating systems and required add ons can be viewed at http www axis com techsup cam_servers tech_notes browsers htm Doc ID 141023 PTO8BA TG ExCam 1 1755 series_en_rev 01 Seite 35 von 44 MCON k GmbH 7 2 Assigning the IP address The ExCam IPQ1755 is an Ethernet network camera requiring an IP address to access it Usually a DHCP server is integrated in most networks which automatically assigns an IP address In case there is no DHCP server available in the network the ExCam IPQ1755 s default address 192 168 0 90 subnet masking 255 255 255 0 is used With the AXIS IP Utility it is possible t
7. PT08BA TG ExCam IPQ1755 series en rev 01 Seite 42 von 44 Q Prozessleittechnik GmbH Doc ID 141023 PTO8BA TG ExCam IPQ1755 series en rev 01 Seite 43 von 44 Prozessleittechnik GmbH Schillerstrasse 17 35102 Lohra Altenvers www samcon eu info samcon eu fon 49 6426 9231 0 fax 31 Bd E 5 E 5 9 E gt E 5 5 gt 2
8. has to reflect the national grounding instructions min 4mm Connection table Potential Color IEC 60757 Profile Comment PE GN YE 4 mm fix Screw terminal Slotted screw M4 x 0 7 DIN 84 with washer 9 mm DIN 125A Table 6 1 Potential equilization Doc ID 141023 PTO8BA TG ExCam IPQ1755 series en rev 01 Seite 19 von 44 Q SAMCON Prozessleittechnik GmbH 6 2 2 Connection and protection Cable gland 2 optional lflex Robust 210 supply heating elements Cable gland 1 SKDxx digitale video stream performance of the camera modules Figure 6 2 Cable gland and supply cable Figure 6 3 ExCam IPQ1755 T08 VA2 2 K1 BOR B XXX K N Doc ID 141023 PT08BA TG ExCam IPQ1755 series en rev 01 Seite 20 von 44 i Figure 6 4 ExCam IPQ1755 T08 VA2 2 K1 BOR B XXX P N Figure 6 5 ExCam IPQ1755 T08 VA2 2 K1 BOR B XXX P K L L The green patch cable SKDxx disposes of 8 1 conductors used for the data transfer with other network devices as well as to power the camera In order to guarantee the power supply Power Device PD of the ExCam IPQ1755 power device PD a Power over Ethernet component Power Sourcing Equipment PSE has to be available at the connecting side e g a PoE Switch a PoE Injector or Midspan which meets the specification IEEE 802 3af of the power class 3 6 49 12 95W 26 30mA A 100 Mbit Ethernet Connection 100BASE T
9. tilted as this runs the risk of damaging the flame proof gap pre venting the transmission of ignition DIN EN 60079 1 2012 Attention The mounting adapter with the heating module the temperature controller the camera module and the optical module are fixed to the cable gland flange Beware also of tilting and work very carefully to avoid damaging the components Avoid skin and clothing contact with the cylindrical fit the surface is treated with lubrication paste oleag inous to protect the surface against frictional corrosion and mechanical strain When opening the housing make sure not to damage or to pollute the Gylon sealing blue The sealing is not firmly attached to the cable and supply flange and isonly fixed by the means of the screw connections Attention Beware not to damage the surface of bore hole and shaft fit at the e flame proof gap preventing the transmission of ignition Attention Please make sure not to damage housing sealings and to keep them clean Doc ID 141023 PTO8BA TG ExCam IPQ1755 series en rev 01 Seite 29 von 44 MQT8K Axis Q1755 IP camera Terminal Phoenix MT1 5 Heating element DBK HP05 Figure 6 13 ExCam IPQ1755 installation components 6 4 3 Removing inserting an SD storage card The ExCam IPQ1755 is delivered with a 16GB SDHC storage card Stored video files can be viewed or deleted via the web Interface and are also ava
10. 005 MQT8K 5X C Function Opening closing of the heating load power circuit bi metal switch heating element type LL are initiated individually and autarkic 2x 005 Switch on temperature 5 C x3 Hysteresis 5 8K Nominal voltage 12 48 V DC Switched current 1 3 A permanent load Contact resistance lt 70 Doc ID 141023 PT08BA TG ExCam IPQ1755 series en rev 01 Seite 9 von 44 3 4 System cable SKDxx Description Shealth color Routing Outer diameter Bending radius Cable Characteristics Interface 3 5 Supply cable optional Description Shealth color Routing Outer diameter Bending radius 9 samcon GmbH Data transfer and power supply of the camera module DIN EN 60079 14 conform Green GN similar RAL6018 via cable gland 1 Ex ADE 4F MsNi Type5 M20x1 5 IIC PXSS2K M 20 x 1 5 cable gland with integrated pressure stop compound 8 7 mm 0 3 mm 100 mm 4x2x AWG22 1 CAT 6a PUR halogen free flame retardant UV resistant chemical resistance shielded see www samcon eu data sheet SKDO1 P version RJ 45 EIA TIA 568B e g Weidmueller IE PS RJ45 FH BK Phoenix Contact VS 08 RJ45 5 Q IP20 etc 10BASE T 100BASE TX PoE K version 8x single pin twisted pair solid conductor 0 64 mm about 5 mm stripped 1x shield Cu braid 2 5 ferules 10BASE T 100BASE TX PoE Power supply of the heating elements including temperature contro
11. 3 Keep the control button pressed until the status light turns yellow figure 6 16 This may take up to 15 seconds 4 Release the control button As soon as the control light is green the ExCam IPQ1755 has been reset to Axis default settings This may take up to one minute The IP address is now 192 168 0 90 subnet 255 255 255 0 5 t is now possible to reassign a new IP address as well as new password If the hardware reset does not deliver the desired results or if the camera displays se vere conflicts or does not function properly anymore e g problems with the browser visualization freezing of the picture or control commands are not carried out anymore it might be necessary to install the latest version of the firmware q v chapter 7 4 Doc ID 141023 PTO8BA TG ExCam IPQ1755 series en rev 01 Seite 31 von 44 GmbH Control button Figure 6 15 Control button LED status bar Figure 6 16 Status display Doc ID 141023 PTO8BA TG ExCam 1 1755 series en rev 01 Seite 32 von 44 9 c GmbH 6 4 5 Closing of the pressure resistant housing For closing the housing please follow in reversed order the steps described in the chater 6 4 2 regarding the opening of the housing Do not use any other screws than those which are part of the delivery scope For the execution with a cable gland 8 x cylin der head screws M4 x 0 7 ISO metric right hand thread with a thread length of 12 mm DI
12. 9 0 0 126 00408CCC0842 AXIS 07401 00408CA1A3A0 89 0 0 144 00408CA1A3A0 AXIS P8221 00408 89 0 0 194 00408CADBEOC AXIS M3014 00408CD27C9F 89 0 0 138 00408CD27C9F ExCam IPQ1755 gt AXIS 01755 00408C8F18E9 89 0 0 86 00408C8F18E9 AXIS P1347 00408CB7F46E 89 0 0 136 00408CB7F46E IPM3014 gt axis M3014 00408CD27C9C 89 0 0 131 00408CD27C9C AXIS P1346 00408CD65BFA 89 0 0 154 00408CD65BFA Figure 7 1 Axis IP Utility Doc ID 141023 PTO8BA TG ExCam IPQ1755 series en rev 01 Seite 36 von 44 MCON GmbH 7 3 Password Identification The default user name is root The default password is root When a system reset of the equipment has been carried out please follow the instruc tions below In order to allow access to the camera the password for the standard administrator user root has to be determined When accessing the camera for the first time the dialog field Configure Root Password is displayed and the password can be determined there For security considerations it is possible to use an encrypted HTTPS connection requiring an HTTPS certificate see steps below For assigning the password via a standard HTTP connection please just enter the pass word directly in the dialog window Configure Root Password For using an encrypted HTTPS connection when determining the password please fol low the below steps 1 Click on the button self signed certif
13. C EN 60529 60 85 60 80 60 85 60 65 60 70 T6 T5 T6 T5 p d V 2 1960 cm3 bto free cross sectional area for free a free gas flow gt 4096 for Ex group according to DIN EN 60079 1 2008 Rheinland number 0035 T V 14 ATEX 7539 X IECEx TUR 14 0026X 557 539 00 14 DE TUR ExTR14 0026 00 DE BVS QAR14 0006 00 1 Maximum ambient temperature range relevant for explosion protection might deviate to the maximum functional temperature range For maximum functional temperature range MTBF see chapter 2 12 Doc ID 141023 PTO8BA TG ExCam IPQ1755 series_en_rev 01 Seite 8 von 44 3 2 Electrical parameters of the camera Axis Q1755 Power supply PoE IEEE 802 3af class 3 Reference power 48 V DC 44 54 V DC Maximum power input 11 2W 3 3 Electrical parameters of the heating optional DBK HP05 1 04 24 Power supply 12 30 V DC Reference power 24 V DC Maximum power input Depending on ambient temperature PTC characteristics P 2 K x A x 5 5 W m Tame gt 30 Max 20 W 1 x heating element 5 12 2 W continuous rating at 30 C inrush current peak 2000 mA typical inrush duration 120 s Typ LL gt 60 40 W 2 x heating elements HPO5 26 8 W continuous rating at 60 C inrush current peak 4000 mA typical inrush duration 120 s Temperature controller B
14. Cam IPQ1755 User manual Prozessleittechnik GmbH 1 introduction PETERE 5 2 en re 7 Technical Data ecc ee 8 3 1 Parameters of the explosion 8 3 2 Electrical parameters of the 9 3 3 Electrical parameters of the heating 9 34 SI DIO nee hie 10 3 5 Supply cable Optional 10 e NINE IRHISNEREERRERG 11 3 7 12 OO 12 39 TOT 12 3 10 Parameterization t TT rS 12 13 3 12 Other technical data tm 13 EE vd 16 5 Illustration of the model 16 b GOMMISSIONING oca dO unc GR 18 NE Eccle em 18 62 Step 2 Electrical CODITGCHOF nee 18 621 Potential NER EX 19 622 Connection and protection cote ntt eren 20 6 2 3 Tests prior to switching on 24 6 3 Testing of the status iub 25 6 4 Step 3 Adjusting the 25 6 4 1 Work preparatiOn iie cnet eruere ex aa ADR EUR EE X FR M EUR Eg Pd ex rad 27 6 4 2 Opening the pressur
15. N 912 ISO 4762 quality 6g are used The material of the screw connection is variable e g stainless steel MNo 1 4301 A2 70 corresponding to the pressure resistant housing or a titan execution Ti22 in metallic red For the execution with a K2 cable gland 7 x cylinder head screws M4 x 0 7 ISO metric right hand thread with a thread length of 30 mm are used Please check that the bore holes and flameproof joint cylindrical fit are clean and intact Attention In case the flameproof joint has been damaged mechanically the housing must not be used anymore Ex Attention Do not lock in any foreign objects inside the housing Please make sure that the disassembled screw locks washer spring DIN 127A are re assembled The Gylon sealing must be intact and has to be reassembled according to the hole pattern of the flange There is no restriction regarding the installation direction of the seal ing If when closing the housing it is noted that the surface of the flameproof joint is dirty or not lubricated sufficiently please clean it with a clean cloth and suitable cleaning deter gent Afterwards re lubricate it with a suitable lubrication agent The screw connection of the flange and housing have to be tightened in crosswise se quence with a torque of 3 Nm Please avoid extensive tightening this might lead to a torn screw If the camera does not provide the anticipated results steps 6 4 2 to 6 4 5 have to be re
16. Q1755 with K1 flange Doc ID 141023 PTO8BA TG ExCam IPQ1755 series en rev 01 Seite 39 von 44 AMCON Prozessleittechnik GmbH T08 VA2 2 K2 BOR B XXX X N housing 10 00 238 00 111 00 280 20 216 00 L _ 1 1 N in m BY 88 00 108 00 L 26 00 56 50 Figure 10 2 Dimensions of the 08 ExCam 1755 with K2 flange Doc ID 141023 PTO8BA TG ExCam IPQ1755 series en rev 01 Seite 40 von 44 Prozessleittechnik GmbH T08 VA2 2 K1 BOR C XXX X LL accessories ex m S o H un n 2 t5 ii L a 00 8EZ xe 00 4LL o RB o n 413 00 weatherproof and protection roof 30 00 50 00 8 50 i 25 00 5 00 215 00 3 00 46 50 30 00 46 00 60 00 wall and ceiling mount 09 901 0549 0000 00 09 ot O pooo e mH E Figure 10 3 Dimensions of the T08 ExCam IPQ1755 accessories Doc ID 141023 PTO8BA TG ExCam IPQ1755 series en rev 01 Seite 41 von 44 Q MCON Prozessleittechnik GmbH 12 Notes Doc ID 141023
17. X is used for the ExCam IPQ1755 data transfer Doc ID 141023 PTO8BA TG ExCam IPQ1755 series en rev 01 Seite 21 von 44 Qs AMCON In case the camera disposes of a plug figure 6 4 it has to be plugged into the RJ45 slot of the network device Due to the design a faulty connection or pin assignment is not possible The network device can already be supplied with power prior to connect ing it to the camera hence there is no power priority which has to be observed In case the ExCam IPQ1755 disposes of a terminal block termination the correct con nection of the individual pins in accordance with EIA TIA 568B has to be observed q v table 6 2 Generally the pins of the same color code are connected Attention The general specification for PoE allows different operation modes for PDs ExCam 1 1354 ExCam IP1355 IPQ1755 etc Mode A end span This is usually used by switches the supply voltage is executed as phantom power on the data lines Both polarities are possible Mode B mid span This is usually used by PoE injectors the power supply and protocol transfer is executed on separate pins plug pin contact 4 5 is the positive pole and 7 8 is the negative pole The 8 ExCam series supports both modes and the used power source PSE determines the mode For executing a reboot it is possible to separate the ExCam IPQ1755 from the network and to switch it on again while in operation or in intera
18. adiation high mechan ical strains etc Due to the usage of high quality PTFE sealings not only the protection level IP68 is reached but also the chemical resistance is maximized Doc ID 141023 PT08BA TG ExCam IPQ1755 series en rev 01 Seite 5 von 44 5 Prozessleittechnik GmbH Figure 1 1 ExCam IPQ1755 with wall mount bracket and roof Doc ID 141023 PTO8BA TG ExCam 1 1755 series en rev 01 Seite 6 von 44 2 Document overview T03 ExCam Series T08 ExCam Series ATEX ATEX IECEx For areas in hazard of gas and dust For areas in hazard of gas and dust explosions explosions EX Installation Manual EC Declaration of Conformity ATEX EC Type Examination Manufacturer s declaration EN 60079 14 EX Installation Manual EC Declaration of Conformity ATEX EC Type Examination IECEx EC Type Examination Manufacturer s declaration EN 60079 14 ExCam vario ExCam vario User Manual Datasheet Technical drawings User Manual Datasheet Technical drawings ExCam miniZoom ExCam miniZoom User Manual Datasheet Technical drawings User Manual Datasheet Technical drawings ExCam niteZoom ExCam niteZoom User Manual Datasheet Technical drawings User Manual Datasheet Technical drawings ExCam maxiZoom E
19. as to be put on checking parts concerning the ignition protection category such as the integrity of the housing the sealings and the cable glands If maintenance measures are necessary they have to be initiated and or executed 9 Repairs and Maintenance Repairs must only be carried out with original parts of SAMCON Prozessleittechnik GmbH Damaged pressure resistant housings have to be replaced completely If in doubt return the applicable part to SAMCON Prozessleittechnik GmbH Repairs concerning the explosion protection must only be carried out by SAMCON Prozessleittechnik GmbH or a qualified electrical technician authorized by SAMCON Prozessleittechnik GmbH in accordance with nationally applied regulations Rebuilding of or alterations to the devices are not permitted 10 Disposal Recycling When disposing of the device nationally applicable regulations must be observed This document is subject to alterations and additions Doc ID 141023 PTO8BA TG ExCam 1 1755 series en rev 01 Seite 38 von 44 OS AMCON Prozessleittechnik GmbH 11 Drawings T08 VA2 2 K1 BOR C XXX X LL housing 315 00 260 20 W zn MT T 1 28 50 rr 1 88 00 108 00 238 00 111 00 il 1 Figure 10 1 Dimensions of the 08 ExCam IP
20. cognition temperature external signals Doc ID 141023 PTO8BA TG ExCam IPQ1755 series en rev 01 Seite 12 von 44 Event actions Local storage 3 11 Network Security Supported protocols 3 12 Other technical data Permitted ambient temperature MTBF Protection level EN 60529 IEC 529 Q Prozessle File upload FTP HTTP E mail notification HTTP and TCP activation of external outlets 96 MB pre and post alarm vid eo buffering SD SDHC internal slot for storage cards of up to 64GB 16GB SDHC included in delivery Scope Password protection IP address filtering HTTPS encryption IEEE 802 1X network ac cess control digest authentication user access log IPv4 v6 http HTTPS QoS Layer 3 DiffServ FTP CIFS SMB SMTP Bonjour UPnP SNMPv1 v2c v3 MIB Il DNS DynDNS NTP RTSP RTP TCP UDP IGMP RTCP ICMP DHCP ARP SOCKS 10 40 C Type 30 40 C Type L 60 40 C Type LL IP 68 Test conditions 24 h 3 m water column at 5 An additional mechanical protection against water jets is recommended Functional temperature range concerning the operational temperature range of the installed components according to manufacture declarations MTBF meantime ration duration between failures For ambient temperature ranges relevant for explosion protection ATEX IECEx see chapter 2 1 Explosion protection Doc ID 141023 PTO8BA TG ExCam
21. ction with a visualization system hot plugging Attention Hot plugging as well as the connection and separation of the data and power cable SKDxx with of network devices and terminal blocks under power is only allowed within the safe area non hazardous atmosphere The pin assignment of the SKDxx according to EIA TIA 568B standard for 100BaseTX with PoE IEEE 802 3af is done as follows Pin Potential Color Plug Cross sec Remarks Mode A Mode B SKDxx pin contact tion area IEC60757 TIA 568B PoE 48 VDC Tx WH OG 1 0 64 mm Solid conductor Tx PoE 48 VDC Tx OG 2 0 64 mm Solid conductor PoE Rx WH GN 3 0 64 mm Solid conductor n a PoE 48 VDC BU 4 0 64 mm Solid conductor n a PoE 48 VDC WH BU 5 0 64 Solid conductor Rx PoE GND Rx GN 6 0 64 mm Solid conductor n a PoE GND WH BN 7 0 64 mm Solid conductor n a PoE GND BN 8 0 64 mm Solid conductor shield GND BK 9 2 5 Shield braid of complete conductor bunch tinned copper wires 220 13 mm AWG 36 shield n a n a 10 n a Aluminum synthe single twisted pair pins tic strapp twisted Table 6 2 Pin assignment SKDxx and plug contact RJ45 Doc ID 141023 PTO8BA TG ExCam IPQ1755 series en rev 01 Seite 22 von 44 MCON GmbH Figure 6 6 RJ45 Contact assignment Particularly in EMC critical environments it is important to eart
22. e resistant 27 6 4 8 Removing inserting an SD storage sss nenne 30 644 Hardware Reset amade 31 6 4 5 Closing of the pressure resistant 33 7 Network access and visualization e ecce nnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 35 7 1 Browser 0 rro 35 7 2 Assigning the IP address 36 7 3 5 ldentification ss ee 37 8 Maintenance Servicing Alterations uuuuuuunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 38 9 Repairs and Maintenance u u suununcenunnnaunnunan anna ura 38 10 Disposal Recycling usus canvas reri CK DIRK Eua 38 11 Drawing S sod cts nenne 39 12 DS ase 42 Doc ID 141023 PT08BA TG ExCam IPQ1755 series en rev 01 Seite 2 von 44 Table of Figures Figure 1 1 ExCam IPQ1755 with wall mount bracket and 6 Table 5 1 Model key f ee 16 Figure 6 1 ExCam IPQ1755 potential 19 Table 5 1 Potential equilization ana ee an 19 Figure 6 2 Cable gland and supply cable 20
23. era as reflected by the LED indicators is as fol lows Status LED Operating mode Color Remarks At normal operation a constant green light shows Note It is possible to configure the status LED in such a manner that in Green normal operation it is not illuminated or only blinks when the camera is accessed It is illuminated permanently when the camera is turned on as well as Yellow when the camera is set back to default settings Red In case of an activation failure the light blinks slowly Usage of the focus asi assistant Table 6 4 Status and control LED 6 4 Step 3 Adjusting the lens Adjusting the lens of the ExCam IPQ1755 is exclusively done via the web interface or the visualization software Mechanical adjustments at the motor zoom lens by the user are not possible Via the web interface s control function it is possible to manually configure the focus as well as the tele range q v figure 6 8 In order to activate the Auto focus as well as advanced functions the Control panel can be used q v figure 6 9 Here back light compensation the infrared cut filter and the iris can be controlled ZOOM wide SE 2 Tele FOCUS Near C ____ 3 Far Auto Figure 6 8 Zoom and focus of the ExCam IPQ1755 Doc ID 141023 PTO8BA TG ExCam 1 1755 series en rev 01 Seite 25 von 44 MCON Control panel Auto focus Off
24. eristics such as mechanical and chemical resistance It is possible to optimize the corrosion behavior in highly acidiferous environments or at offshore applications by selecting the applicable housing material An electro polished or powder coated surface in various RAL colors standard RAL7035 is possible Dimension stainless steel housing T07 VA2 2 with pin and without cable gland and external accessories For additional detailed dimensions see chapter 10 technical drawings Dimensions camera housing 7 VA2 2 with wall mount bracket and roof pointing forward Doc ID 141023 PTO8BA TG ExCam 1 1755 series en rev 01 Seite 14 von 44 Q Prozessle VICON k GmbH Fitting of the flame proof gap preventing the transmission of ignition cylinder EX T07 VA2 2 Nominal diameter 91 mm Clearance fit H8 f7 DIN ISO 286 Tolerance 71um 54um Gap length gt 12 5 mm Gap width lt 0 15 mm Average surface finish Ra lt 6 3 um Media resistance excerpt Acetone alcohol acetylene ammoniac aniline benzol butane chloride pressurized water pressurized air ethane crude oil fluoride glycerin sea water methane oils phosphoric acid propane etc 7 Additional media resistance as well as well as validation of chemical resistances possible upon request Doc ID 141023 PTO8BA TG ExCam IPQ1755 series en rev 01 Seite 15 von 44 4 9 c Safety guidelines Please observe the safety guidel
25. g heavy duty AWG 26 22 Type Weidmueller IE PS RJ45 FH BK pin assignment accord ing to EIA TIA 568B Supply lflex Robust 210 n a upon request Normal ambient temperature range MTBF 10 40 C Low ambient temperature range MTBF 1 30 40 C Lowest ambient temperature range MTBF Tame 60 40 C Doc ID 141023 PTO8BA TG ExCam 1 1755 series en rev 01 Seite 17 von 44 9 c 6 Commissioning amp Attention Please observe the national regulations regarding security installa tion and accident prevention e g DIN EN 60079 14 as well as the safety guidelines described in this user manual and the EX installation manual Attention Please observe the installation and commissioning advices described in the Ex installation manual 6 1 Step 1 Installation Install the ExCam IPQ1755 at the desired location Mounting options accessories as well as safety guidelines are described in the EX installation manual of the ExCam se ries 6 2 Step 2 Electrical connection Attention The electrical connection of the equipment must be executed by quali fied personnel only Attention It is mandatory that the housing of the ExCam Series has to be grounded via a PE connection Attention The minimum cable length of the connection line must not be less than one meter The connection cable has to be laid in a protected manner
26. h the shield at the terminal block side q v figure 6 3 pin with black shrink tubing and blue ferule 10 shield 9 shield GND Figure 6 7 SKD01 Pin assignment In case the ExCam IPQ1755 is supplied a PoE capable device an additional safe guarding of the power supply is not necessary The power supply is executed by the PoE network device via an electronic with intelligent set up The camera as well as the con nection is permanently monitored in order to avoid any failure or defects in case of a short circuit fault For a camera with terminal block execution it is possible to operate the camera either with a PoE capable network device or with a separate 48 V DC power supply supply voltage and network streams are self sustaining In this event an adequate supply safe guarding has to be dimensioned Recommended is a 300 mA medium time lag fuse Doc ID 141023 PTO8BA TG ExCam 1 1755 series en rev 01 Seite 23 von 44 Qs AMCON If the Ex CCTV application calls for a separate 48 V DC supply voltage the wire pin as signment has to reflect Mode B operation mode q v table 6 2 If the camera is equipped with a heating type L or type LL a second power supply with a separate supply protection at the L has to be available Standardly the supply is car ried out via the supply cable Olflex amp Robust 210 cable gland 2 q v figure 6 2 and 6 5 Connection assignment and supply protection accordi
27. i 1920x1080 px HDTV 720p 1280 x 720 px 16 9 Color 2 0 lux at 30 IRE F1 8 BW 0 2 lux at 30 IRE F1 8 Doc ID 141023 PTO8BA TG ExCam 1 1755 series en rev 01 Seite 11 von 44 3 7 Processor Type Storage 3 8 Lens Type Angle of view Focus range Shutter time Zoom 3 9 Streaming Video compression Frame rate Functions 3 10 Parameterization Image settings Intelligent Video Event triggers MCON GmbH ARTPEC 3 256 MB RAM 128 MB Flash f 2 5 1 51 0 mm F1 8 2 1 auto focus automatic day night operation M37 x 0 75 connecting thread for an optional lens adapter 48 1 5 1 horizontally 27 1 2 9 vertically 16 9 0 1 infinite wide 0 8 m infinite tele 1 10000 s to 1 2 s 9 50 60Hz net frequency 10 fold optical zoom 12 fold digital 120 fold maximum H 264 MPEG 4 Part 10 AVC Motion JPEG 30 fps H 264 at all resolutions 25 fps Motion JPEG at all resolutions Multiple individually configurable streams in H 264 and Motion JPEG controllable frame rate and bandwidth VBR CBR H 264 Compression color brightness sharpness contrast white balance exposure control backlight compensation picture rotation 0 90 180 270 including Corridor Format text and image overlay privacy mask mirroring of images Video motion detection active tampering alarm audio recognition gate keeper Video motion detection active tampering alarm audio re
28. icate 2 Enter the desired information and click OK The certificate is issued and the password can be entered Please note that the entire data transfer of the ExCam IPQ1755 will be encrypted 3 Enter the desired password and repeat it in order to ensure correct spelling Click on OK to configure that password 4 Enter the username root it is not possible to delete the default administrator user name root 5 Enter the previously determined password and click on In case you have forgotten the password the ExCam IPQ1755 has to be reset to default settings 6 Click on Yes in order to install AMC AXIS Media Control After the completion of the installation it is possible to view the video streams with the Microsoft Inter net Explorer or Mozilla Firefox administrator rights are required 7 The page Live View of the ExCam 1 1755 is now displayed With the setup link itis possible to open the menu options to allow personal camera settings Doc ID 141023 PTO8BA TG ExCam 1 1755 series en rev 01 Seite 37 von 44 9 c GmbH 8 Maintenance Servicing Alterations The national regulations concerning the maintenance and servicing of electrical devices within hazardous areas are to be observed The required maintenance intervals are specific to the individual devices The operating company has to determine these intervals depending on the application parameters Dur ing maintenance focus h
29. ilable on the download list http The videos stored on the storage card can also be accessed via an FTP server within the network ftp If it should become necessary to exchange the stor age card please use an empty one which has been pre formatted with an ext4 or VFAT data system The storage card slot is situated on the back of the camera module q v figure 6 14 SD storage card slot e Figure 6 14 SD card slot Doc ID 141023 PTO8BA TG ExCam 1 1755 series en rev 01 Seite 30 von 44 9 GmbH Please pay attention when inserting removing the storage card not to damage the ter minals and the connection cable Do not bend the mounting adapter as otherwise this may affect the optical axis of the camera When touching electrical components potential equalization grounding of the body has to be observed carry a PE wristband etc 6 4 4 Hardware Reset In order to reset all parameters including the IP address of the ExCam IPQ1755 to de fault settings a hardware reset has to be carried out The parameters can be reset via the web surface or also manually If the camera is not accessible in the network the reset has to be carried out manually To do so please fol low the steps below 1 Disconnect the camera module Axis Q1755 from the power supply 2 Hold the control button pressed q v figure 6 15 while at the same time switch ing on the power supply PoE
30. ination 14 7539 X and IECEx TUR 14 0026X T07 Ex d housing with large diameter 113 mm and large sight glass 72 mm T07 housing with maximum body length Ir 238 mm K1 cable gland flange straight cable gland s K2 cable gland flange orthogonal cable gland Doc ID 141023 PT08BA TG ExCam IPQ1755 series en rev 01 Seite 16 von 44 VA2 2 K1 BOR 005 9 samcon GmbH Borosilicate sight glass Standard execution for video cameras within visible spectral range 350 2000 nm and near Infra red not suitable for thermographic applications Alternatively Germanium GER zinc sulfide ZnS Flir Explosion group IIB Standard execution Suitable for all gases except hydrogen acetylene carbon disulfide flammable fibrous material and non conductive dusts Explosion group Optional execution Suitable for all gases flam mable fibrous materials and conductive dusts Length of the connection line in meter at delivery The standard cable length is 5 m minimum maximum cable length 001 100 m Terminal block execution standard SKDxx 8 x single pin twisted pair solid conductor 0 64 mm about 5 mm stripped 1x shield Cu braid 2 5 mm ferules Supply lflex Robust 2102 x 2 5 mm2 Cu litz wire with ferule sheath about 10 cm stripped and furnished with bend re lief shrink tubing Plug termination optional SKDxx RJ 45 network plu
31. ines indicated in der EX installation manual of the T08 ExCam series 5 Illustration of the model key The following model options are currently available for the ExCam IPQ1755 Ex product name Model options 1 Type Housing Gas expl Cable length m cable Tempera combination group SKDxx SKLxx termin 9 ture range ExCam IPQ1755 T08 VA2 2 K1 BOR B 005 K N T08 VA2 2 K1 BOR B 005 P N T08 VA2 2 K1 BOR C 005 K N T08 VA2 2 K1 BOR C 005 P N T08 VA2 2 K2 BOR B 005 K N T08 VA2 2 K2 BOR B 005 P N T08 VA2 2 K2 BOR C 005 K N T08 VA2 2 K2 BOR C 005 P N ExCam IPQ1755 T08 VA2 2 K1 BOR B 005 K L T08 VA2 2 K1 BOR B 005 P L T08 VA2 2 K1 BOR C 005 K L T08 VA2 2 K1 BOR C 005 P L ExCam IPQ1755 T08 VA2 2 K1 BOR B 005 K LL T08 VA2 2 K1 BOR B 005 P LL T08 VA2 2 K1 BOR C 005 K LL T08 VA2 2 K1 BOR C 005 P LL ExCam IPQ1755 T08 VA2 2 K1 BOR VA2 2 K1 BOR VA2 2 K1 BOR VA2 2 K2 BOR Table 5 1 Model key Functional camera description of the ExCam IPQ 1755 Distinctive characteristics are for example Sensor resolution light sensitivity angle of view iris control zoom characteristics wide tele optical digital motor driven varifocal etc Certified production type device designation 8 ExCam series EC type exam
32. ller Robust 210 DIN EN 60079 14 conform Black BK matt similar RAL9005 via cable gland 2 Ex 4F MsNi Type5 M 20 x 1 5 IIC PXSS2K M 20 x 1 5 cable and cable gland with integrated pressure stop compound 7 6 mm 15 x outer diameter for occasional movement 4 x outer diameter for fixed installation Further cables available upon request e g lflex Petro FD 865 high resistance against oil and drilling liquids XPLE Armoured 3 x 2 5 extremely robust particularly designed for offshore environments Doc ID 141023 PTO8BA TG ExCam IPQ1755 series en rev 01 Seite 10 von 44 Conductor design Characteristics Isolation Nominal voltage Uo U Test voltage Interface 3 6 Sensor Axis Q1755 Type Effective sensor resolution Light sensitivity Q Prozessle ACON GmbH 2 x 2 5 mm litz wire made of blank fine wire copper according to 0295 5 IEC 60228 5 no earth conductor pins twisted in layers pin isolation made of modified PP Special TPE halogen free flame resistant UV and ozone resistant high chemical resistance heat and cold resistance reduced outer diame ter 20GO0xcm 300 500 V AC DC 4000 V P version N A or upon request version 2 x 2 5 Cu litz wire BK BK with ferule sheath about 10 cm stripped and furnished with bend relief shrink tubing 1 3 RGB CMOS progressive scan HDTV 1080
33. lly explosive atmosphere when opening the camera housing de installation of the camera and execu tion of the work within the safe area non EX Doc ID 141023 PTO8BA TG ExCam IPQ1755 series en rev 01 Seite 27 von 44 OS AMCON Prozessleittechnik GmbH In case the 08 ExCam IPQ1755 is equipped with a protection roof it has to be removed first To do so loosen the four 8 mm lens head screws M4 0 7 at the front and back of the bracket figure 6 10 and figure 6 11 Figure 6 11 Removing the protection roof 2 To open the enclosure 07 VA2 2 of the ExCam IPQ1755 loosen the four hexagon socket screws DIN 912 ISO 4762 located at the cable gland flange of the stainless steel housing including the washer springs DIN 127 A q v figure 6 10 Avoid skin or clothing contact with the screw threads as they dispose of LOCTITE 6 243 chemical basis Dimethacry latester It is used to protect the screws from losing due to shocks vibrations but also for sealing purposes It is not allowed to open the sight glass flange Doc ID 141023 PT08BA TG ExCam IPQ1755 series en rev 01 Seite 28 von 44 Figure 6 12 Opening the ExCam IPQ1755 Pull out very carefully the lead flange in a straight manner ensuring that the board modle does not tilt Due to the created lower pressure this might require some additional effort The oylindrical clearance fit H8f7 DIN ISO 286 of the body as well as of the flange components must not be
34. lution CMOS sensor with a 10 fold optical zoom this network camera is particularly suitable when observing objects in greater dis tance opting for an extremely detailed visualization The camera is intended for inside as well as outside use preferably within hazardous areas of the chemical and or petro chemical industry at offshore plants in mines and at biogas plants The ExCam IPQ1755 is suitable for the usage within the Ex zones 1 2 21 and 22 in cluding the gas group all gases steams and fogs including acetylene hydrogen and carbon disulphide and the dust group conductive dusts and flammable fibrous material as well as in mining Within the equipment group mining the camera series can be used in areas with a low risk of mechanical danger In case the camera is to be used in areas with a high mechanical risk the optical components sight glass have to be protected suitably Within the equipment group II all hazardous areas except mining the ExCam IPQ1755 is without any additional mechanical protection suitable for all areas with a high mechanical risk Besides for fixed installation the T08 ExCam series is also certified to be used for mobile applications hand held etc The Ex d stainless steel housing allows additional alloys a powder coating or coats of varnishes as well as various mechanical accessories in order to extend the resistance towards extreme environmental conditions salt water acid solar r
35. ng to table 6 3 Potential Color lflex Cond Voltage Maximum power in Maximum power in Pin no Robust 210 design put protection put protection IEC60757 type L type LL 1 BK 2 5 24 VDC 20 W fuse L 2000 40 W fuse L 4000 litz wire mA T time lag mA T time lag L 2 BK 2 5 mm 0 VDC GND high inrush current high inrush current litz wire 6 2 3 Tests prior to switching on voltage AN A Attention Table 6 3 Pin assignment supply cable Prior to commissioning all tests as indicated by the national regula tions have to be executed In addition it is mandatory that the proper functioning of the operating device in accordance with this user man ual and all other applicable regulation has been executed Attention Incorrect installation and operation of the camera may lead to a loss of warranty Doc ID 141023 PTO8BA TG ExCam IPQ1755 se ries en rev 01 Seite 24 von 44 9 GmbH 6 3 Testing of the status LED Through the sight glass the status LED is visible Prior to finishing the installation pro cess and accessing the camera via the web interface the proper functioning of the cam era should be tested The booting process of the ExCam IPQ1755 may take up to one minute Additional LEDs for checking network activities or the bandwidth are only visible when the housing is open The status of the applicable network cam
36. o determine the IP address under Windows the included USB stick contains this application It is also available for download http www samcon eu en downloads drivers software In case it is not possible to assign the IP address it might be necessary to change the firewall settings The AXIS IP Utility tool automatically recognizes all ExCam devices and displays them It can also be used to manually assign a static IP address Please note that the ExCam IPQ1755 network camera has to be installed within the same network segment physical subnet as the computer on which the AXIS IP Utility tool is executed For example the ExCam IPQ1755 network identification is Axis 1755 q v figure 7 1 MAC address and serial number are also determined and displayed so that a non ambiguous identifica tion is possible Datei Ansicht Werkzeuge Hilfe re E 31 51 Name IP Adresse Seriennummer AXIS 2330 00408C82E5C1 89 0 0 122 00408C82E5C1 AXIS 07404 Channel 4 00408CCC0845 89 0 0 125 00408CCC0845 ExCam IP1354 gt AXIS P1354 00408CF2961E 89 0 0 135 00408 CF2961E AXIS P1346 00408CD65BF7 89 0 0 153 00408CD65BF7 AXIS Q7404 Channel 2 00408CCC0843 89 0 0 127 00408CCC0843 AXIS P1346 00408CD65BFE 89 0 0 151 00408CD65BFE AXIS 241QA 00408CA00AA7 89 0 0 123 00408CA00AA7 AXIS 07404 Channel 3 00408CCC0844 89 0 0 128 00408CCC0844 AXIS P1346 00408CD65BF8 89 0 0 152 00408CD65BF8 AXIS 07404 Channel 1 00408CCC0842 8
37. peated For the fixed installation of the ExCam IPQ1755 either with a wall mount bracket with a hinge attachment for sight glass installations or for the optional installation of a roof please observe the instructions of the EX installation manual Doc ID 141023 PTO8BA TG ExCam IPQ1755 series en rev 01 Seite 33 von 44 Q Prozessle VICON k GmbH The T08 ExCam series is certified to be also used for mobile applications hand held etc The cylinder head screws for the safe connection of the housing body and the flange have to be tightened with a torque of 3 Nm Doc ID 141023 PTO8BA TG ExCam IPQ1755 series en rev 01 Seite 34 von 44 9 c GmbH 7 Network access and visualization In the following the most important steps for the initial commissioning of the camera are described The configuration menu of the web surface allows an intuitive navigation and offers several configuration possibilities For a comprehensive user manual of the web surface please refer to the to the Axis user manual which can be found on the provided USB stick or which can be accessed at ExCam IPQ1755 http www axis com files manuals um q1755 45216 en 1111 pdf Network access of the ExCam IPQ1755 is supported by most operating systems and browsers The recommended browsers are Internet Explorer with MS Windows Safari with Macintosh and Firefox with Windows and additional operating systems To carry out video streaming via the
38. rational work carefully and in accordance with the applicable regulations Attention Note Depending on the zone classification it might be necessary to obtain a work permit clearance When adjusting the camera settings potentially explosive atmosphere must be avoided by any means To allow the camera delivering the best picture quality please consider the lighting conditions the object distance and size the angle of view as well as the minimum object distance for focusing when selecting the installation place Use appropriate tools e Make sure you have a secure foothold e Avoid static charge 6 4 2 Opening the pressure resistant housing Opening the pressure resistant housing DIN EN 60079 1 2008 of the ExCam IPQ1755 is only allowed in case the SD storage card has to be removed or replaced or that a Hardware Reset of the camera module is necessary additional mechanical and electrical interventions inside the Ex d housing by the user are not allowed and are only to be executed by SAMCON Prozessleittechnik After the completion of the work the pressure resistant housing has to be closed to be explosion proof again Please be very careful and follow thoroughly the steps of this manual amp WARNING DO NOT OPEN IN HAZARDOUS AREA Note Depending on the zone classification it might be necessary to obtain a work permit clearance Even after disconnection of the volt age it is mandatory to avoid potentia
39. xCam maxiZoom User Manual Datasheet Technical drawings ExCam IP User Manual Datasheet Technical drawings ExCam IPM3014 User Manual Datasheet User Manual Technical drawings Datasheet Technical drawings ExCam HD ExCam IP135x Serie User Manual Datasheet Technical drawings User Manual Data sheet ExCam IP1354 Data sheet ExCam IP1355 Data sheet ExCam IP1357 Technical drawings ExCam IPQ1755 User manual Datasheet Technical drawings Doc ID 141023 PT08BA TG ExCam IPQ1755 series en rev 01 Seite 7 von 44 CON 3 Technical Data MCON GmbH 3 1 Parameters of the explosion protection Identification marks according to Directive 94 9 EG Explosion protection gas Explosion protection dust Explosion protection mining Protection level Transportation and storage temperature EX Operation temperature EX Ambient temperature EX Pressure chamber internal design Nominated body EC Type Examination Test protocol ATEX Test report IECEx Quality Assessment Report 9 Il 2G zone 1 and 2 x II 2D zone 21 and 22 x 1 M2 Ex d T6 Gb or Ex d Gb or d IIB T6 Gb T5 Ex tb IIIC T80 C Db IP68 or Ex tb IIIC T95 C Db IP68 or Ex tb IIIB T80 C Db 1 68 or Ex tb IIIB T95 C Db IP68 Mb IP 68 IE

Download Pdf Manuals

image

Related Search

Related Contents

GMC 2005 Automobile User Manual  Téléchargez le document  VA2448-LED-1, VA2448M-LED-1 User Guide, Spanish/Español  Nikon 13302 Digital Camera User Manual  Great Quality… Incredible Price www.atleaf.com  Toshiba Satellite E55-A5114  Inova CTPT-6LPZ User's Manual  IMS 100 English Deutsch Français  Panasonic 新型ホームエレベーター  

Copyright © All rights reserved.
Failed to retrieve file