Home
USER MANUAL - Kramer Electronics
Contents
1. define the VA 100P Power Supply O Pl Power Supply VA 100P Max 500mA per output Max 3000mA total current 12V DC OUTPUTS Figure 1 VA 100P Power Supply Table 1 Features and Functions of the VA 100P Power Supply Feature Function 1 POWER Switch Illuminated switch for turning the unit ON or OFF 2 12V DC Power OUTPUTS Connect to the power inlet on a 12VDC unit from 1 to 10 Can output 12V DC to up to 3A or maximum 500mA per output up to 6 outputs at any one time It can supply 300mA to each of the 10 outputs simultaneously 3 Power Connector with FUSE AC connector enabling power supply to the unit 2 KRAMER SIMPLE CREATIVE TECHNOLOGY Using the Power Supply 5 Using the Power Supply To use your VA 100P as the example in Figure 2 illustrates do the following 1 Connect up to 10 power outlets using DC to DC cables The example in Figure 2 illustrates how to connect the 72V DC OUTPUT 1 power outlet to the 72V DC power inlet on a Kramer FC 14 RGBHV to Component Transcoder and how to connect the 12V DC OUTPUT 10 power outlet to the 12V DC power inlet on a Kramer Tools 810 Color Bar Audio Generator 2 Connect the power cord to the mains electricity VA 100P Figure 2 Connecting the VA 100P Power Supply 1 Supplied with the VA 100P 3 Technical Specifications 6 Technical Specifications Table 2 Technica
2. FR 47 FCC Rules and Regulations Part 15 Radio frequency devices Subpart B Unintentional radiators CAUTION B Servicing the machines can only be done by an authorized Kramer technician Any user who makes changes or modifications to the unit without the expressed approval of the manufacturer will void user authority to operate the equipment B Use the supplied DC power supply to feed power to the machine B Please use recommended interconnection cables to connect the machine to other components 5 For the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com where updates to this user manual may be found We welcome your questions comments and feedback Safety Warning Disconnect the unit from the power supply before opening servicing Caution 9007 O 2 QU a Institute of Quality amp Control Kramer Electronics Ltd Web site www kramerelectronics com E mail info kramerel com P N 2900 000064 REV 2
3. Kramer Electronics Ltd ah KRAMER USER MANUAL Model VA 100P Power Supply Contents Contents 1 Introduction 2 Getting Started 3 Overview 4 Your Power Supply 5 Using the Power Supply 6 Technical Specifications Figures Figure 1 VA 100P Power Supply Figure 2 Connecting the VA 100P Power Supply Tables Table 1 Features and Functions of the VA 100P Power Supply Table 2 Technical Specifications of the VA 100P Power Supply bb U N me pa N Introduction 1 Introduction Welcome to Kramer Electronics since 1981 a world of unique creative and affordable solutions to the infinite range of problems that confront the video audio and presentation professional on a daily basis In recent years we have redesigned and upgraded most of our line making the best even better Our 300 plus different models now appear in 8 Groups which are clearly defined by function Congratulations on purchasing your Kramer VA 100P Power Supply which is ideal for any audio video system using multiple 12V operated products as well as battery replacement for field battery operated equipment The package includes the following items e VA 100P Power Supply unit e 10 DC to DC cables and a power cord e This user manual 2 Getting Started We recommend that you e Unpack the equipment carefully and save the original box and packaging materials for possible future shipment e Review the contents of th
4. ied or removed 35 Damage deterioration or malfunction resulting from i Accident misuse abuse neglect fire water lightning or other acts of nature ii Product modification or failure to follow instructions supplied with the product iii Repair or attempted repair by anyone not authorized by Kramer iv Any shipment of the product claims must be presented to the carrier v Removal or installation of the product vi Any other cause which does not relate to a product defect vii Cartons equipment enclosures cables or accessories used in conjunction with the product WHAT WE WILL PAY FOR AND WHAT WE WILL NOT PAY FOR We will pay labor and material expenses for covered items We will not pay for the following 1 Removal or installations charges 2 Costs of initial technical adjustments set up including adjustment of user controls or programming These costs are the responsibility of the Kramer dealer from whom the product was purchased 3 Shipping charges HOW YOU CAN GET WARRANTY SERVICE 1 To obtain service on you product you must take or ship it prepaid to any authorized Kramer service center Ze Whenever warranty service is required the original dated invoice or a copy must be presented as proof of warranty coverage and should be included in any shipment of the product Please also include in any mailing a contact name company address and a description of the problem s 3 For the name of the nearest Kramer auth
5. is user manual e Use Kramer high performance high resolution cables 3 Overview The Kramer VA 100P Power Supply e Isan efficient ten outlet universal switching power supply that can output 12V DC to up to 3A or a maximum of 500mA per output up to 6 outputs at any one time It can supply 300mA to each of the 10 outputs simultaneously e Is designed to operate Kramer products that normally use an external 12V DC power transformer e Can save valuable space on power strips by replacing up to ten wall transformers 1 GROUP 1 Distribution Amplifiers GROUP 2 Video and Audio Switchers Matrix Switchers and Controllers GROUP 3 Video Audio VGA XGA Processors GROUP 4 Interfaces and Sync Processors GROUP 5 Twisted Pair Interfaces GROUP 6 Accessories and Rack Adapters GROUP 7 Scan Converters and Scalers and GROUP 8 Cables and Connectors 2 Download up to date Kramer user manuals from the Internet at http www kramerelectronics com 3 The complete list of Kramer cables is on our Web site at http www kramerelectronics com 1 Your Power Supply e Is mains fed and is housed in a half 19 enclosure Take care to ensure that the polarity of the unit which is to be connected matches that of the VA 100P that is that positive center pin To achieve the best performance we recommend positioning your VA 100P in a location free from moisture and away from excessive sunlight and dust 4 Your Power Supply Figure 1 and Table 1
6. l Specifications of the VA 100P Power Supply INPUT POWER SOURCE 230 VAC 50 60 Hz 115VAC U S A 60 VA OUTPUTS 10 x 12VDC outputs to up to 3A or maximum 500mA per output up to 6 outputs at any one time It can supply 300MA to each of the 10 outputs simultaneously DIMENSIONS 22cm x 18cm x 4 5cm 8 7 x 7 x 1 7 W D H half 19 1U WEIGHT 1 2kg 2 6 lbs approx ACCESSORIES Power cord 10 DC to DC cables OPTIONS RK 80N 19 rack kit 1 Specifications are subject to change without notice 4 KRAMER SIMPLE CREATIVE TECHNOLOGY LIMITED WARRANTY Kramer Electronics hereafter Kramer warrants this product free from defects in material and workmanship under the following terms HOW LONG IS THE WARRANTY Labor and parts are warranted for seven years from the date of the first customer purchase WHO IS PROTECTED Only the first purchase customer may enforce this warranty WHAT IS COVERED AND WHAT IS NOT COVERED Except as below this warranty covers all defects in material or workmanship in this product The following are not covered by the warranty 1 Any product which is not distributed by Kramer or which is not purchased from an authorized Kramer dealer If you are uncertain as to whether a dealer is authorized please contact Kramer at one of the agents listed in the web site www kramerelectronics com Ze Any product on which the serial number has been defaced modif
7. orized service center consult your authorized dealer LIMITATION OF IMPLIED WARRANTIES All implied warranties including warranties of merchantability and fitness for a particular purpose are limited in duration to the length of this warranty EXCLUSION OF DAMAGES The liability of Kramer for any effective products is limited to the repair or replacement of the product at our option Kramer shall not be liable for 1 Damage to other property caused by defects in this product damages based upon inconvenience loss of use of the product loss of time commercial loss or 2 Any other damages whether incidental consequential or otherwise Some countries may not allow limitations on how long an implied warranty lasts and or do not allow the exclusion or limitation of incidental or consequential damages so the above limitations and exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from place to place NOTE All products returned to Kramer for service must have prior approval This may be obtained from your dealer This equipment has been tested to determine compliance with the requirements of EN 50081 Electromagnetic compatibility EMC generic emission standard Part 1 Residential commercial and light industry EN 50082 Electromagnetic compatibility EMC generic immunity standard Part 1 Residential commercial and light industry environment C
Download Pdf Manuals
Related Search
Related Contents
Manual de instalación Aufsatzkasten TOP DUO store - Hella Sonnen 唐お買い上げ誠にありがとうございました。 夢ご使用の前によくお読みの DEWE-43 user manual inForm - User Help Novembre 2013 Copyright © All rights reserved.