Atrie WireSpan 4000 IDSL
Contents
1. Line Impedance 135 ohms balance Voice and data service simultaneously Provide FXO interface at Central side and FXS interface at remote side Option Voice interface meet ITU T G 712 transmission requirements Wide choice of DTE port V 24 V 35 G 703 and X 21 Programmable flow control CTS RTS and Anti Streaming delay time WireSpan 4000 IDSL Rack Unit Data Rate Synchronous 4 8k 9 6k 19 2k 38 4k 56k 64k 72k 1 12k 128kbps Asynchronous 4 8kbps 9 6kbps 19 2kbps 38 4kbps Line Operation Full duplex over 2 wrie subscriber line up to 5 5km 26AWG cable Support the V 110 rate adaption Line Rate 160 Kbps Base on ISDN U interface Fully Compliant with ANSI T1 601 1992 specification Transmit Level 13 7 dBm Line Impedance 135 Ohms Line Interface RJ 45 Teminal Block Line interface circuitry protects against lightning and power surges WireSpan 4000 IDSL User s Manual 3 DTE Interface V 35 RS 232D V 28 G 703 Diagnostics Testing LL RL DL DTE Loopback BERT build in 511 Input Voltage AC90 260 Volts 47 63Hz or 36 to 72 Vdc Single or Daul power option Power Consumption 5W Max Per 10 LEDs Indicators SYN TST TD RD CD RTS CTS DTR DSR PWR Rack Size 1 16 port 16 pieces per Rack with Power Module in 19 Rack Shelf 482mm L x8 3 210mm W x175mm H Operating 1 Temperature 0 to 45 C Operating 2 Relative Humidity 0 to 80 non condensing Clock Source Select Internal External Loop
2. Remote Configuration Enabled 5 1 Show Setup This screen can be viewed from the current Modem Setup with the following parameters Data Rate Port Type Clock Source Anti Stream On Off Anti Stream Time Test Time RTS gt CTS Delay Time DCD Off Delay Time CTS DSR DCD On and Off status Voice Port Status 5 2 Show I F Signal remote device only If the remote modem are being configured this command will show the existing interface control signal status CTS RTS DCD DSR and DTR The indicate signal is ON CTS RTS DCD DSR DTR OK Or Rack Unit CTS RTS DCD DSR DTR LEDs is ON 5 3 Change Setup 5 3 1 Data Rate Sync and Async data rate are provided Synchronous 4 8k 9 6k 19 2k 38 4k 48k 56k 64k 72k 112k 128 kbps Asynchronous 4 8k 9 6k 19 2k 38 4kbps 5 3 2 Control Signal a CTS Follow remote DCD Follow local RTS and Always ON b DSR Follow remote DTR Follow local DTR and Always ON c DCD Follow remote RTS Always ON or Follow By Sync Once the DSL line is synchronized the DCD is turned ON automatically d Anti Streaming Switch ON Switch OFF Anti Streaming is a method of preventing domination by any one modem during half duplex operation by forcing CTS off if RTS remains on over a given amount of time Anti Streaming Time 5 3 3 Timer a RTS gt CTS ON Delay Time from 0 to 255ms increment by 5 ms This feature provides a given delayed time to turn CTS on after RTS is ON b DCD
3. OFF Delay Time from 0 to 255ms increment by 5 ms DCD ON signal continues for a given period of time after the loss of line signal DCD is OFF c Anti Streaming Time from 0 to 255 seconds increment by 5 seconds 5 3 4 Clock Source a Internal Central Site Modem select internal free running clock as a master clock b External Central Site Modem follow external DTE clock as a master clock c Received Remote Site Modem extracted clock from received line signal 5 3 5 Error Seconds Threshold The WireSpan 4000 IDSL samples the number of CRC error per 60 300 and 900 seconds simultaneously known as Error Seconds Each of these Error Seconds has a minimum and maximum level When the Error Seconds goes over the maximum threshold the modem triggers the alarm When the Error Seconds falls below the minimum level it will automatically cut off the alarm a ES60s Provide minimum 00 to maximum 060 error seconds setting per 60 seconds period b ES300s Provide minimum 00 to maximum 300 error seconds setting per 300 seconds period c ES900s Provide minimum 00 to maximum 300 error seconds setting per 900 seconds period WireSpan 4000 IDSL User s Manual 9 5 3 6 Remote Configuration In order to prevent unauthorized person to change configuration WireSpan 4000 IDSL provides a facility to enable or disable configuration from remote modem a Unit Enable Enable configuration to the remote modem b Unit Disable D
4. WireSpan 4000 V 35 Stand Alone Unit aD CHis cHi4 a3 CHi2 HI1 CH1O 87654321 10 BASET ON I u mMm OFF WA LIA LIA 21B LIB LIB 3PA L2A none FG CHS a3 C11 4PB 12B none STXA G703TXA 6IXB G703TXB 7RXA G703RXA 8RXB G703RXB NVGO AC POWER a la oe e E a g 5 Figrue 3 2 WireSpan 4000 Rack Back pane CH 0 15 DB25 Female DTE Connecter You can to use Standard DB25 DB25 or DB25 M34 Change Cable Only ATRIE defined to connect V 24 V 35 Interface FG SG F ground Signal ground DC 48V GND 48 Vdc input AC POWER 90 260 Vac input L1A LIB ID Line interface to Others WireSpan 4000 Non polarity G703TxA B_ Only for WireSpan 4000 Rack Unit is G 703 Interface Co direction unit Attention The RJ45 Terminal Block is to be linked together It s suggest to use 8P 2C RJ45 cable to connect other WireSpan 4000 When use G 703 interface to connect other DCE Device 10 BASE T SNMP Ethernet connecter CONSOLE Reserve function WireSpan 4000 IDSL User s Manual Dedicated V 35 Change Cable Definition Only WireSpan 4000 IDSL Rack System by used A B D SUB 25 M M34F OOO of of 1 FG FG a 0505 2 SDA SDA p s o 3 o 3 RDA RDA
5. coding to allow reliable and cost effective full duplex transmission at speed up to 128 Kbps and Voice port over one pair of existing copper subscriber lines It provides data and voice services simultaneously Adaptive equalization and echo cancellation ensures consistent performance even over poor quality lines It has a comprehensive V 54 loop test function allowing easy optimal speed calibration and troubleshooting without the need for a cable tester The stand Alone unit is easy to use and configure through a menu driven LCD control panel The Rack unit is easy to use and configure through DIP switch and push button The WireSpan 4000 IDSL satisfies the requirements of a variety of high speed data communication applications 2 Features and Specification WireSpan 4000 IDSL Stand Alone Unit Menu driven 2 x 16 LCD control panel for easy configuration and diagnostics Configuration and set up verification of remote unit Comprehensive error reporting with external alarm trigger Built in 511 pattern generation detection and V 54 remote digital loopback Data Rate Synchronous 4 8k 9 6k 19 2k 38 4k 48k 56k 64k 72k 112k 128 kbps Asynchronous 4 8k 9 6k 19 2k 38 4kbps Line Operation Full duplex over 2 wire subscriber line up to 5 5km 18 kft 0 4mm cable complying to ANSI T1 601 ITU T G 961 specification Transmission Synchronous 2B1Q line coding with adaptive echo cancellation and equalization Transmit Level 13 7 dBm
6. pair issynchronized Loop Test indicator Transmit data indicator Receive data indicator Data Carrier Detect Request To Send Clear To Send Data Terminal Ready Data Set Ready Lights when power is ON 4 Command Menu Tree of WireSpan 4000 IDSL Local amp Remote Configuration Password Control Enable Disable Enter Password Data Rate Syne Mode Async Mode Flow Control Signal CTS DSR DCD Anti Streaming Timer RTS gt CTS On Delay DCD Off Delay Anti Streaming Clock Source Internal External Received Voice Control Select A U Law FXO FXS control Reset Default Setting Save Changes for local configure only Send Configure for remote configure only View Local amp Remote Configuration Data Rate WireSpan 4000 IDSL User s Manual Port Type Clock Timer Test Time Flow Control Signal for remote configure only Diagnostics LL Test RL Test RAL Test LL 511 Test RL 511 Test RAL 511 Test DL 511 Test DL Test 511 Test Pattern Test Time Test Time infinite Test Time 5 min to 255 min 5 Configure the WireSpan 4000 IDSL The Modem has been configured at the factory with the following default settings PARAMETERS DEFAULT Data rate 64 kbps CTS Always On DSR Always On DCD Always On Anti Streaming Off RTS to CTS Delay 50 ms DCD Off Delay 0 ms Anti Streaming timer 30 seconds Clock Source Internal Error Seconds Threshold 60 seconds
7. Atrie WireSpan 4000 IDSL MODEM User s Manual Atrie WireSpan 4000 IDSL User s Manual Version 1 3 TABLE OF CONTENT 1 I ducti ifi e 2 Features and SPECICATION S sissesiasiivnieninannnsiinasmnnraniue eS 3 Installaatiot isseire iA 3 1 WireSpsan 4000 IDSL Witing eeesseeeessscesssceesssooe seseessseoessnecessneessneeessneeessseeossseessseesse 3 2 WireSpsan 4000 IDSL Stand Alone Front Panel Operation csssseeeees0 4 Command Menu Tree of WireSpan 4000 IDSL 7 Configure the WireSpan OET EES SP Show SCCUp sacar initi esii a E A E A E EEO h ignal devi ly 5 2 Show I F Signal remote device only ss eesesesssccssossssscosssesccsssssecesssescosssesecessssecesss 8 53 Chang SetUPuenesirieieeiir iiia a i A K Ei E ETE EEs 5 31 Data RACE sscsaccvensisscnssassencsecscsscrxse less eaveczots cerca costes ap tiv EEEE i RRRS 1 Signal 5 9 2 Control SIS a escossonar a T AARE E AEEA Ti 5 5 5 TIMET inie a ine E EE EE EEEE RE BDA Clock Source scecterssssacsiaesinsaietsaiaesassaddivapcgessigassncesanisthauadssasieantes ia 5 3 5 Error Seconds Threshold sessesssessesssessesessessecssesseesseesesssesssoseesseesseesesesesseess fi i 1 5 3 6 Remote Configuration ssseseesesssecsesssecoess sossecesessescsessseesesssseeesessseesessseesessseseess 0 7 Foll fil 1 5 3 7 Follow Profil ncgsssesieninesnaonnnnnei k e nna a i faul 1 5 5 8 Set Unit Default c 4 nGnguauiuurdwsrrnumnagindungudetens
8. Management Lacal Configuration Remote Configuration SNMP Console Option 3 Installation 3 1 WireSpan 4000 IDSL wiring Once you unpacking the WireSpan 4000 IDSL unit the following accessories are included AC Power Cord 1 pces Stand Alone Only Connection box 1 pes Stand Alone Only RJ 11 Cable 1 pcs Voice Module 1 pcs option for Stand Alone Follows the steps and figure3 1 to install the Stand Alone unit follows the steps and figure3 2 to install the Rack unit The pin definition of the following each connector Please refer to section 3 descriptions Step 1 Step 2 Step 3 Step 4 Step 5 Install DTE cable to the external equipment properly WireSpan 4000 IDSL provides V 35 V 24 and G 703 data ports Install RJ 11 Stand Alone RJ 45 Rack Unit cable to the other end of WireSpan 4000 IDSL Only for Stand Alone Install Voice Module option from rear panel and push to the seat properly Please unscrew the voice module cover firstly Make sure the FXO module is installed in the Central Site local carrier company or switches the FXS is in the remote site to the telephone set or PBX Make sure the power switch is turned OFF and install AC power cord auto range from AC 90V to 260V with Stand Alone or AC DC power card 36Vdc to 72Vdc in Rack Unit Turn ON power switch and enjoy it DTE Port WS V 35 V 24 SS G 703 X 21 To AC Power 90 260 V To DTE To Other IDSL Figure 3 1 Wiring
9. R o o 7 4 RTS A RTS Sf 6 lo 5 CTSA CTS 7 0 fo 6 0 6 9 6 DSR A DSR E sc sc 3 7 B OOO i DCD A DCD 20 RCB RCB x ANA 5 XTCB XTC B fa O 18 TCB TCB AA Fe m ee aa Up VU eae o M34 F 4 SDB SDB 5 epee mato twisted pair H TCA TCA y 2 Po a o A B 25 RDB RDB T r Oe Oe p 5 it RCA RCA 7 Oy ie z AA O BB O R T G O DD E OE S c p 8l O m O JI KK O LL P F a E ey oO ar x w _ JU a an N OOO i j XTCA XTCA SCALE 2 3 Ro 3 2 WireSpan 4000 IDSL Stand Alone Front Panel Operation A TD RD ALM PWR At A rie IDSL Access Unit Wire Span Ae ve SYN TST T a gt ENTER EXIT DTR DSR DCD RTS CTS v 2x 16 characters LCD Display the Command Menu of Modem Status Alarm messages and Configuration v Push buttons y LED displays lt gt Scroll through available options ENTER Choose current option EXIT PWR SYN TST ALM RD TD a Go back to previous menu Lights when power is ON Sync indicators Blinks until DSL pair is synchronized Loop Test indicator Error detect Receive data indicator Transmit data indicator Voice Port Status indicator ON Off Hook OFF On Hook or No voice port Flashing Ring Arie LED displays l SYN i TST SYN TD L gt TST p RD cp RTS GF RTS CTS lt b CTS DTR DSR APWR PWR WireSpan 4000 IDSL Sync nicators Blinks until DSL
10. annlO 9 Voi I Only ch ble b d Al i 1 5 3 9 Voice Control Only changeable by Stan one Unit sis sy5010 4 i 1 5 4 Reset DEVICE siesena ae nae nan una uaemeanaae lO 5 5 SAVE SEUD eene n a a a eenas iaaa 9 9 9 9 9 9 6 Diagnostic of the WireSpan 4000 IDSL sessessssesssssesseseseoseseesseseee LL 6 1 LL Test Local Loopback Test eesesssessosesoseosseosssoscosssossessesssoseossoosoessossesseessoseesseese L 6 2 RL Test Remote Loopback TeSt csssssssesesscossscssssssssssessssssssssessssssssesesssssesseeoL L 6 3 RAL Test Remote Anolog Loopback TeSt sssssssssssesssssssessesseessssssssssessssssssesseee I 6 4 DL 511 Test Digital Loopback with 511 Test Pattern seseeesesescccsssssscocsssseceesse 12 6 5 LL 511 Test Local Loopback with 511 Test Pattern sseessoesssossscsscoessessseessees 12 6 6 RL 511 Test Rocal Loopback with 511 Test Pattern sesseesssesssossscosssesseeseeese 12 6 7 RAL 511 Test Remote Loopback with 511 Test Pattern sseesssosssesssoesecesseess 12 6 8 DL Test Digital Loopback essssesssssesssssssssesecosssscossesooseseossssoossscossesessseessseeesseeeesseeeesses LO 6 9 511 Test Pattern sorca s n n R R NR R R 610 Test TUM es ccisisssscciscssivssncnsscvossvesin siecdenesssacucnsuensavesnsestuasesensovedeccssesviecGentbanctvessieveve i i 7 SetUp Copy Configuartion Only for Rack Mount 13 1 Introduction The WireSpan 4000 IDSL uses 2B1Q line
11. isable configuration to the remote modem 5 3 7 Follow Profile This feature allows the current modem Setup to be a Data Port Profile The LCD will display Set Data Port as Profile 5 3 8 Set Unit Default This command setup the current modem with predefined default parameters Total is 6 default parameters option List below table Default Number Clock Source Data rate 1 Internal 64K 2 Internal 128K 3 External 64K 4 External 128K 5 Received 64K 6 Received 128K Control Signal is non changed Factory default value 5 3 9 Voice Control Only changeable by Stand Alone Unit The WireSpan 4000 IDSL provides FXO or FXS voice port on the modem card If the voice port is installed and enabled the data rate is restricted under 64 kbps data rate automatically The FXO port is connected to the Central Office CO or PSTN Switches the FXS is connected to the regular telephone set or private PBX Key Telephone system WireSpan 4000 IDSL detect FXO FXS voice module automatically and can be enabled or disabled by CM unit The voice is transmitted with 64 kbps PCM code A or u Law a FXO FXS Enable Disable Enable or Disable voice module b A u Law Configure voice with A Law or u Law 64 kbps PCM code 5 4 Reset Device Select this command will reset the current Modem module The Modem module re start according to the pre defined setting 5 5 Save Setup After finished configuration tthe f
12. odem Line Interface A i Digital Interface 6 3 RAL Test Remote Analog Loopback Test Test from the local DTE up to the line interface of the Remote unit The WireSpan 4000 IDSL Pair has to be in Sync mode Line Interface af t Digital Interface WireSpan 4000 IDSL User s Manual 11 6 4 DL 511 Test Digital Loopback with 511 Test Pattern Testing using 511 BERT pattern generated from the remote unit up to the digital interface of the local unit The WireSpan 4000 IDSL Pair has to be in Sync mode E5 a i Line Interface A Digital Interface 6 5 LL 511 Test Local Loopback with 511 Test Pattern Test using 511 BERT pattern generated from the local unit up to the line interface of the local unit Local Remote ja Line Interface a Digital Interface 6 6 RL 511 Test Remote Loopback with 511 Test Pattern Test using 511 BERT pattern generated from the local unit up to the digital interface of the remote unit The WireSpan 4000 IDSL Pair has to be in Sync mode Local Remote DTE Modem Modem DTE ee I prea Gen Line Interface f Digital Interface 6 7 RAL 511 Test Remote Analog Loopback with 511 Test Pattern Test using 511 BERT pattern generated from the local unit up to the digital interface of the remote unit The WireSpan 4000 IDSL Pair has to be in Sync mode Local Remote e Modem Line Interface ae Digital Interface 12 6 8 DL Test Digital Loopback Testing u
13. ollowing SAVE information NOTE All Change Setup have to be saved in order to save to non volatile RAM After reset or power off the modem the Change setup parameters can be resumed 10 6 Diagnostic of WireSpan 4000 IDSL The WireSpan 4000 IDSL has 8 sets of V 54 loop tests It also has an internal 511 Bit Error Rate Test BERT pattern generator These loop tests allow you to check the reliability of the installation to calibrate for optimum performance or in case of problems to do troubleshooting The different loop tests are described in the following table To activate these functions please follow the following Command Menu Tree Local Device or Remote Device gt Device Management gt Diagnostic The test interval of each test is defined by Test Time at the following command If the test need to be stopped immediately press and lt key and then OK key to stop the test command The following V 54 looptest with 511 test pattern will indicate the Error Bits show ErrBits Jon the LCD display immediately Press and lt key and then OK key to stop the test command 6 1 LL Test Local Loopback Test Test from the local DTE up to the line interface of the local unit Local Remote WE Line Interface i Digital Interface 6 2 RL Test Remote Loopback Test Test from the local DTE up to the Digital interface of the Remote unit The WireSpan 4000 IDSL Pair has to be in Sync mode Local Remote e M
14. sing 511 BERT pattern generated from the remote unit up to the digital interface of the local unit The WireSpan 4000 IDSL Pair has to be in Sync mode Local Remote DTE Modem Modem DTE a Ss a ee eee Line Interface at Digital Interface 6 9 511 Test Pattern The WireSpan 4000 IDSL generates a 511 test pattern between both local and remote sides to verify the data transmission are working well To perform this feature both sides have to enter 511 Test Pattern mode Press lt and gt key on the local front panel under this mode to send an error bit to remote modem Press one key to generate one error bit TP_511 running TP_511 running ErrBits 0 ErrBits 2 Press and gt key on the Generate error bits on the local Modem remote Modem 6 10 Test Time a Time infinite Setup test time infinite until manual stop b Time 005 min to 255 min Setup test time duration from 5 minutes up to 255 minutes increment by 5 minutes 7 Setup Copy Configuration Only for Rack Mount In order to provide a faster method for setting up several modems You can use copy configuration menu and choose one of Rack mount to copy setup to another rack mount This function is effective when ROM version on Rack Mount is the same 13 WireSpan 4000 IDSL User s Manual