Home
the Installation Instruction
Contents
1. Commands Menu item Description Application Adjustment range Factory setting EN DE 20 Switch solenoid valve a Function test for the valve On lt OK gt Off Valve Flushes until it is switched off again b Flushing of standing water Off lt OK gt Ventil stops automatically after 10 min stagnation c Disinfection of the pipe section and the tap Minimum 3 min at a minimum of 7O C d Winter emptying 21 Check detection range Problems with user detection On lt OK gt Off RangeTest Red LED in IR window Off lt OK gt TestErfas lights up if an object comes into the detection range No flush is initiated switches off automatically after 90 s 22 Reset sensor a In the event of detection malfunctions Start lt OK gt ResetSens IR sensor recalibrates itself b Environment has changed e g new ResetSens washbasin 23 Factory settings In the case of malfunctions Start lt OK gt FactrySet All functions are reset to the factory Werkseinst setting 24 Switch cleaning function Cleaning the tap and the washbasin Start lt OK gt CleanMode The tap is inactive for 90 s without the water running Reinigung Programs Menu item Description Application Adjustment range Factory setting EN DE 30 Select main menu Selecting one of the three programs Presence A A MainProgr Presence Flushes as long as an object Water saver B Hauptmen is in the detection range Run on C Water saver see m
2. and battery terminals can result in burns or damage to property Ensure that the tap housing is only ever pushed onto the valve block in the correct position Only connect the battery to the contacts in the battery holder 12 Steps a c must be performed four times in a row a Press the tap housing onto the contacts until b LED lights up for 1 s then c push the tap housing back up immediately by 3 cm MGEBERIT cLOc6 90 L00 887S0 D54883 001 06 2012 A Enabling cleaning Enables one person to manually start the cleaning function see Care and maintenance The function remains continuously activated 1 Activate manual mode see Activating manual mode Manual mode will remain active for 30 min Set the function within this period 2 Cover the IR window completely with your hand Water will stop after 5 s Remove your hand immediately 3 B Setting the flush time to the factory setting The flush time is set to the factory setting The tap flushes as long as an object is in the detection range 1 Activate manual mode see Activating manual mode Manual mode will remain active for 30 min Set the function within this period 2 Cover the IR window completely with your hand Water will stop after 5 s Wait until a further water impulse has occurred Remove your hand immediately 3 MGEBERIT Manual settings C Setting the water saver The tap flushes as
3. are not completely open Basket filter in water supply valve is blocked or dirty Differentiated pressure of the hot and cold water pipe is higher than 1 5 bar Reinforced braided hose is kinked Check valve in tap housing or on reinforced braided hose is blocked Water temperature is too low or too high Reinforced braided hoses are not connected correctly cold with hot and hot with cold Troubleshooting Fault clearance Open the angle stop valves completely Clean or replace the basket filter e See Maintenance Adapt the differentiated pressure of the two pipes e Lightly close the angle stop valve at the pipe with the higher pressure e Install a flow regulator or a water pressure reducing valve Rectify the kink Rectify the blocking or replace the check valve Check the temperature of the water net or storage water heater Connect the reinforced braided hoses correctly Settings using the Geberit Service Handy Settings using the Geberit Service Handy The numbers and terms in the column Menu item correspond to what can be seen on the display of the Geberit Service Handy Further information can be found in the operating instructions of the Geberit Service Handy G The Geberit Service Handy must be set to bidirectional mode WE Fa a Information given in corresponds to the text displayed on the Geberit Service Handy Information given in lt gt refers to buttons on the Geberit Service Handy
4. detection distance until the LED is constantly lit for 1 s and a water impulse follows for 1s Reset all settings All settings are reset to the factory settings and manual mode is deactivated The process for resetting the control is the same as for gt Activating manual mode but step 3 must be repeated six times MGEBERIT cL0t 90 L100 88YS0 D54883 001 06 2012 Care and maintenance The following maintenance work is required as needed but no later than on the specified time interval Cleaning the surface weekly Cleaning the tap aerator monthly Cleaning the basket filter yearly Close the angle stop valves The tap can be deactivated for 90 s for cleaning purposes Prerequisites The cleaning function is enabled see Settings using the Geberit Service Handy Enabling cleaning CAUTION h Aggressive and scouring cleaning agents will AA damage the surface Never use aggressive cleaning agents that are acidic abrasive or corrosive or contain chlorine Only use water and a mild cleaning agent Cover the IR window completely with your hand The flow of water stops after 5 s ua Be A ur 3 Remove the generator version with below desk n e _ _ TT mixer Remove your hand The cleaning function is now active Clean the tap with a soft damp cloth Dry the tap with a soft dry cloth Remove the shut off screw and the tap aerato
5. long as an object is in the detection range but no longer than 10 s 1 Activate manual mode see Activating manual mode Manual mode will remain active for 30 min Set the function within this period 2 Cover the IR window completely with your hand Water will stop after 5 s Wait until 2 further water impulses have occurred 3 Remove your hand immediately D Setting the run on time to 120 seconds Once you have removed your hand the tap will continue to flush for 120 s 1 Activate manual mode see Activating manual mode Manual mode will remain active for 30 min Set the function within this period 2 Cover the IR window completely with your hand Water will stop after 5 s Wait until 3 further water impulses have occurred 3 Remove your hand immediately 13 Manual settings E 14 Setting the detection range he detection distance from the IR window to the hand is set Activate manual mode see Activating manual mode Manual mode will remain active for 30 min Set the function within this period 2 Remove all objects from the detection range u Cover the IR window completely with your hand Water will stop after 5 s Wait until 4 further water impulses have occurred 4 Remove your hand immediately The function is now activated 5 Hold your hand at the current detection distance until the LED in the IR window flashes Then place your hand at the desired
6. objects in the room Improvement of the detection safety in case of external influences e g strongly reflecting washbasins Adjustment range Factory setting On ON Off OFF Adjustment range 6 48 h 3 180 s 1 168 h 1 180 s 3 180 s On O I On CO O O O a ll Off 0 Auto 1 Dynamic 2 Off 0 Auto 1 Dynamic 2 OFF Factory setting 24 h 24 3 s 3 168 h 168 120 s 120 10 s 10 16 19 cm 2 Auto 1 Auto 1 Settings using the Geberit Service Handy Counters Menu item EN DE 50 Days SumBetrT 51 Uses SumBenut 52 IntFlush SumIntSp 53 Days SumBetrT 54 Uses SumBenut 55 IntFlush SumintSp Unit info Menu item EN DE 60 TypeNo Modell Nr 61 SWVersion SWVersion 62 SerialNo Serien Nr 63 ManufDate ProdDatum 64 TyoePower Netz Batt 65 Battery Batterie 10 Description Total number of days of operation Displays the number of days of operation since commissioning Total number of uses Displays the number of uses since commissioning Total number of interval flushes Displays the number of interval flushes since commissioning Number of days of operation power on Displays the number of days of operation since the unit was last switched on Number of uses power on Displays the number of
7. uses since the unit was last switched on Number of interval flushes power on Displays the number of interval flushes since the unit was last switched on Description Type number Indicates the article number of the tap does not apply if the IR sensor has been replaced Software version Indicates the software version of the IR sensor e g 0312 version 3 12 Serial number Indicates the serial number of the current IR sensor Manufacturing date tap Indicates the manufacturing date of the tap Does not apply if the IR sensor has been replaced e g 1007 calendar week 10 2007 Type of power supply Indicates whether it is a mains operated AC or a battery operated DC tap Battery capacity Indicates the current battery capacity in The battery must be replaced at 00 Output days USES flushes days of operation USES flushes Output MGEBERIT cL0c 90 L100 88YS0 D54883 001 06 2012 Manual settings Manual settings The tap allows to set a limited number of functions manually without using the Geberit Service Handy The setting is performed with the infrared sensor The manual mode must be activated before the functions A E can be set see Activating manual mode Overview of functions Functions A E A Enable cleaning B Set flush time to factory setting C Set water saver D Set run on time to 120 seconds E Set the detection dista
8. MGEBERIT Instandhaltungsanleitung Manuel d entretien Istruzioni per la manutenzione KNOW HOW INSTALLED Table of Content Table of Content TIO onere iene ail iene 2 IR i 2 FON E EES a EE E E E E E A A ee AE ETTA a 2 CAO RIA 2 PIOSUCB EI CHIC A ee ee ee ee 2 QUI RR RIA 3 FI NORD Dee er E E ETE en n 4 RUDI 4 Settings USING the Geberit Service Fandy nie ee ee ea nee 8 VE RE E E RE RA 11 PG NN ICE PIN TOO e cot ERE EA ETE 2 PS MOOI SICH een ae e Adern Eee ee ne Ben Eier E ee Beten cote es 13 B Setting the flush time to the factory setting er ee ee a ie ee i 13 C Setting the water Saver rai rina 13 D Setting the run on time to 120 secondS ee 13 E Setting the detection range 14 ROS OE SONOS enne 14 Gare ANA Dance ee ee alan niro 18 Cleaning the surface cleaning function nenne neces nennen nennen nenne nnsnnnnnnennnnnnnnnnnsenennnnenennnsnnennssnenensnenensnnennsnnennnnnnn 15 GIESHIRG ANS TAG SE AlOr riale atei i air i inedito 15 eann e o O een ae ee ee ee are seca eases 15 Bi PER E 17 Target group This document is intended for use by skilled persons as defined by EN IEC 62079 2001 Explanation of symbols Symbol Meaning CAUTION Refers to a potentially dangerous situation that may cause slight or moderate injury or material damage Refers to important information Safety notes Repairs may only be carried out by a skilled person using original spare parts and accessories Do not mo
9. alve Replace the solenoid valve Clean the contacts or replace the IR sensor Replace the IR sensor Check the lavatory tap generator and control using the battery charger e See Checking the lavatory tap and the generator and Checking the generator unit control and charging the battery in the battery charger user manual Troubleshooting Problem The LED in the IR sensor flashes continuously and the tap does not work The LED in the IR sensor does not flash and the tap does not work Water runs constantly and stops if an object appears in the detection range Continuous flow water does not stop Water runs although shut off screw has been removed Water starts to run by itself Tap is leaky water dripping from tap Possible cause e Battery level is too low e Battery level is too low e Spring contact probes between IR sensor and solenoid valve connected the wrong way round e Interfering objects in the detection range e R sensor is defective e incorrect sensor mode e Pressure in water net is too high e Solenoid valve is defective e R sensor is defective e R window is scratched or dirty e Tap is being adversely affected by influences in the room mirrors metal surfaces glass washbasins etc e Pressure fluctuations in the water net e Leaks in water way defective seals e Vater drops out of water outlet solenoid valve does not close properly Fault clearance Check the lavatory ta
10. dify the lavatory tap or add any additional modules Product classification This document describes the maintenance work for the following Geberit products 116 335 21 1 Geberit lavatory tap type 185 generator without mixer 116 365 21 1 Geberit lavatory tap type 185 generator with below desk mixer 116 336 21 1 Geberit lavatory tap type 186 generator without mixer 116 366 21 1 Geberit lavatory tap type 186 generator with below desk mixer 116 450 00 1 generator conversion set for Geberit lavatory tap MGEBERIT cL0t 90 L100 88YS0 D54883 001 06 2012 Structure CONDO OA AN 9 Tap housing Shut off screw Tap aerator IR sensor Battery holder Power adapter resource saving Generator unit control Adapter for reinforced braided hose Clamping device 10 Generator 11 Bracket 12 Cover 13 Below desk mixer 14 Adapter for angle stop valve 15 Basket filter 16 Reinforced braided hose 17 Reinforced braided hose 18 Check valve 19 Long nut 20 Threaded rod 21 Fastening sleeve 22 Flat gasket 23 Valve block 24 Solenoid valve MGEBERIT 15 Functional principle Functional principle When water flows from the angle stop valve 1 to the lavatory tap 2 the generator 3 generates an electric current The current is stored in the rechargeable battery 4 The rechargeable battery then provides the lavatory tap with electricity so that it can be used D lt Fu
11. enu item 44 Run on time see menu item 43 31 Select energy saver Extension of the battery lifetime On ON OFF Esaver Reduces the reaction speed of the IR Off OFF E Sparen sensor after the time from menu item 40 ESaverT has elapsed after the last use 32 Enable cleaning Prerequisite for starting the manual On ON OFF CleanEn Enables one person to manually start the cleaning function Off OFF FreiReini cleaning function see Care and maintenance MGEBERIT cL0c 90 L100 88YS0 D54883 001 06 2012 Programs Menu item Description EN DE 33 Select interval flush IntFlush Starts the interval flush program The tap IntervSp flushes automatically at the interval dictated by the entered value from menu item 42 IntervalT for the duration of the entered value from menu item 41 IntFlushT after the last use Parameters Menu item Description EN DE 40 Set start time energy saver ESaverT Is active if 31 Esaver is selected in EnerSparZ menu item ON 41 Set interval flush flush time IntFlush T Is active if 38 IntFlush is selected in IntervSpZ menu item ON 42 Set interval flush flush interval IntervalT Is active if 38 IntFlush is selected in IntervalZ menu item ON 43 Set run on time RunOnTime Is active if 30 MainProgr is selected in NachlaufZ menu item C The tap continues to flush with the input value after the object ha
12. nce Further functions Reset all settings GEBERIT Description Enables one person to manually start the cleaning function see Care and maintenance The function remains continuously activated See A Enabling cleaning on the following pages The flush time is set to the factory setting The tap flushes as long as an object is in the detection range See B Setting the flush time to the factory setting on the following pages The tap flushes as long as an object is in the detection range but no longer than 10s See C Setting the water saver on the following pages Once you have removed your hand the tap will continue to flush for 120 s See D Setting the run on time to 120 seconds on the following pages The detection distance from the IR sensor to the hand is set See E Setting the detection distance on the following pages All settings are reset to the factory settings and manual mode is deactivated See Resetting all settings on the following pages 11 Manual settings The following instructions show a battery operated tap The same procedure applies to mains operated and generator operated taps The manual mode is active for 30 min All functions can be set within this period Prerequisites Tap is operable Water supply valve is open Battery is fully charged LED in the IR window does not flash Mains current is present CAUTION Short circuiting the spring contact probes
13. nctional diagram of lavatory tap with generator The lavatory tap can be operated for at least ten years if it is used for at least 80 seconds per day 20 uses for a duration of 4 seconds each In the case of prolonged use surplus energy is produced thus increasing the charge level of the battery Due to minimal self discharge and its large storage capacity the battery remains charged for downtimes of several months In the case of shorter usage times the charge level of the battery is gradually reduced 3 4 Pb Battery charge level Legend Time axis Charge level axis Self discharge of rechargeable battery and standby power consumption of lavatory tap Solenoid valve of lavatory tap opens water flow starts Water flows charging current is generated Solenoid valve of lavatory tap closes water flow stops Energy surplus OURWBN lt X MGEBERIT cL0t 90 L100 88YS0 D54883 001 06 2012 Troubleshooting Troubleshooting ren To charge the rechargeable battery and to check the Geberit lavatory taps with generator the battery charger 116 452 00 0 1 is required Problem Possible cause Fault clearance No water e The LED in the IR sensor flashes 6 times after each use GEBERIT Angle stop valves are closed Tap aerator is blocked or dirty Basket filter is blocked or dirty Reinforced braided hose is kinked No pressure in water net Shut off screw is missing or defective Tap is in cleani
14. ng mode Detection distance is not adjusted correctly IR window is scratched or dirty Interfering reflections from the washbasin Generator produces no or too little electricity Battery level is too low Solenoid valve contacts are corroded Solenoid valve is defective IR sensor contacts are corroded IR sensor is defective Battery level is low Open the angle stop valves Clean or replace the tap aerator e See Care and maintenance Clean or replace the basket filter e See Care and maintenance Rectify the kink Check the water pressure e Restore the water pressure Insert or replace the shut off screw Wait for the end of the cleaning mode approx 2 min Correctly set the detection range e See Settings using the Geberit Service Handy or Manual settings Clean the IR window or replace the IR sensor Correctly set the detection range e See Settings using the Geberit Service Handy or Manual settings Check the lavatory tap generator and control using the battery charger e See Checking the lavatory tap and the generator and Checking the generator unit control and charging the battery in the battery charger user manual Check the lavatory tap generator and control using the battery charger e See Checking the lavatory tap and the generator and Checking the generator unit control and charging the battery in the battery charger user manual Clean the contacts or replace the solenoid v
15. p generator and control using the battery charger e See Checking the lavatory tap and the generator and Checking the generator unit control and charging the battery in the battery charger user manual Check the lavatory tap generator and control using the battery charger e See Checking the lavatory tap and the generator and Checking the generator unit control and charging the battery in the battery charger user manual Connect the plug connection correctly Remove objects from the detection range e Then remove the shut off screw and insert it again Do not disturb the detection process wait until the water flow stops and the LED in the IR window is no longer lit Replace the IR sensor Change the sensor mode or reset the sensor e See Settings using the Geberit Service Handy or Manual settings Check the pressure in the water net e Set the net water pressure to 0 5 8 0 bar Replace the solenoid valve Replace the IR sensor Clean the IR window or replace the IR sensor Reset the sensor e See Settings using the Geberit Service Handy or Manual settings Install a suitable pressure regulator Check the connections in the water way e Replace the seals if defective Clean or replace the solenoid valve MGEBERIT CL0c 90 L100 88YS0 D54883 001 06 2012 Problem Temperature cannot be adjusted properly GEBERIT Possible cause No or not enough hot or cold water Angle stop valves
16. r using the key provided Clean the tap aerator and reinstall the shut off screw MGEBERIT 2 Care and maintenance version without below desk mixer 5 Clean the basket filter 6 Reassemble everything by following the steps in reverse order 7 Open the angle stop valves 16 MGEBERIT cL0t 90 L100 88YS0 D54883 001 06 2012 Disposal Disposal Constituents This product meets the requirements of the directive 2002 95 EC RoHS Restriction of Hazardous Substances in electrical and electronic equipment Disposal In accordance with directive 2002 96 EC WEEE on waste electrical and electronic equipment manufacturers of electrical equipment are obliged to take back old equipment and to dispose of it correctly The symbol indicates that the product cannot be disposed of with non recyclable waste Old equipment should be returned directly to Geberit where it will be disposed of appropriately Please contact your responsible Geberit sales company or visit www geberit com for collection point addresses GEBERIT Li Geberit International AG Schachenstrasse 77 CH 8645 Jona dokumentation geberit com gt www geberit com 965 891 00 0 00 D54883 001 06 2012
17. s been removed from the detection range 44 Select running time water saver WSaverT Is active if 30 MainProgr is selected in TWSparenZ menu item B The tap flushes as long as an object is in the detection range but not longer than the input value 45 Set detection range DetectRng Manual setting 0 Place your hand in Erfassdis the detection range until the LED in the IR window flashes Hold your hand in the desired detection distance until the LED lights up for one second and a water impulse follows 46 Set upper sensor operation SensorUp Off IR sensor is switched off It is not SensOben possible for both IR sensors to be switched off at the same time Auto IR sensor switches automatically to Dynamic if required Dynamic IR sensor only reacts to moving objects 47 Set lower sensor operation SensorLow Off IR sensor is switched off It is not SensUnten possible for both IR sensors to be switched off at the same time Auto IR sensor switches automatically to Dynamic if required Dynamic IR sensor only reacts to moving objects MGEBERIT Settings using the Geberit Service Handy Application a Hygiene b Flushing out of stagnant water Application a Hygiene b Cleaning of implements a Water saver b Extracting a certain amount of water Individual adjustment of the detection distance Improvement of the detection safety in case of external influences e g strongly reflecting