1.       User Calibration          In case of severe overload the scale may lose its accuracy  Re   calibration of the scale may be needed  The load cell of this precision  scale is normally protected against overloaded weight applied slowly  but  extreme overload caused by dropping the scale or dropping something  heavy on the scale may require re calibration     CAUTION  Please do not attempt any calibration by yourself unless you  have a 5lb weight available     Make sure the scale is connected to the PC via USB cable or to AC  mains  Press the ON TARE key and hold it for about 5 seconds  When    the display changes to   release the ON TARE key  Now the  scale is in user calibration mode  the LCD also displays 5lb on the left  corner   Put 5lb weight on the platform  After the weight is stable  scale  will calibrate itself  Once the calibration is completed  scale will enter the  normal weighing mode     EL ANE    USB30    USB Electronic Postal Scale   Max  30Ib d 0 10z   3 way power  USB  AC Adapter or Battery   With fold up platform for weighing large flats or mailing tubes  Connects with PC to output weight   Switchable to 15kg 1g scale    The USB70 is a high quality precision electronic digital scale with  weighing function and USB connection to a computer to output weight in  applications  Please read this manual on how to use this product           SPECIFICATIONS       Range    Tare   Accuracy   Factory Calibration  User Calibration  Resolution  Minimum Weight  Min  Add
2.  on Wt   Power    Warm up time  Display  Auto Off    Temperature  Case  amp  Platform  Fold up Platform    Load Cell Technology      Load Cell Body      0   30lb  0   15kg     Mechanical overload protection      Unlimited to the total capacity of the scale     0 1   of reading   1 digit     4 points through the capacity range     5lb 2000g     0 102  1g      0 102  1g      0 102  1g      AC Adapter  9V  100mA  Optional  or    USB  Self powered or  Battery  9V alkaline battery  Not supplied       1 minute or less    7 segment 6 digit LCD    Auto off after 5 minutes of non use in battery    operation      Good performance within 50 to 105 degrees F    ABS plastic    For convenient weighing of round and flat objects  Four optimal placed single precision strain gauges  with temperature compensation      High Tensile Strength Aluminum Alloy       Operating Instructions             Unpacking and Assembling the Scale          Switching to GRAM Weight Display          Unpack the scale and if the scale came from a colder or warmer  environment let it first stay for some time to be at the same temperature  as your current environment  Fix the weighing platform gently to the body  of the scale via the four location points  The slope edge of the platform  should face the front part  The scale must be installed on a firm and flat  surface     The scale is set to display the weight in pounds and ounces by default    The scale can be changed to display weights in grams  g   Turn on scale  _
3. ON_   and wait until 0 00z is displayed  Press the Giaims key for about 5   seconds and then release the key  The display should have changed to   0g  Repeat the same steps to switch back to pounds and ounces display              Using the Scale with Power Adapter          Tare Function          Connect the supplied power adapter to the input socket at the rear of the  scale and plug it into the power supply  It is advisable to remove the  battery when using the power adapter           Using the Scale with Power Battery          Remove the battery compartment cover underneath the scale  Insert a  9V alkaline battery and connect to the battery snap  Replace the battery  compartment cover           Using the Scale with Computer and USB Power    You can tare  set to zero weight  any item used as a container for other  items or liquids in the following way    _ON_   If the scale is switched off  press the Whi key with nothing on the  platform and wait for 0 00z  or ra to display  Place the container on the  platform  and then press the key  The display will show 0 00z  or  0g  with T displayed on the left side of LCD  Place the item to be    weighed into the container on the platform  The scale will now show the  net weight of the item  minus the container weight                         Connect the square plug of the supplied USB cable to the back of the  scale  Connect flat plug of the cable to an available USB port   Windows Mac will automatically recognize the scale and instal
4. l the  appropriate driver once it is turned on and detected as USB HID device   The power adapter is not necessary when the scale is connected to the  computer via USB     Interfacing and Weight Display to PC             Scale Startup    Connect the square plug of the supplied USB cable at the side of the  scale  Connect flat plug of the cable to an available USB port of the  computer  Elane supplies the program for displaying the weight from the  scale  A DLL is also available for customized applications using the  scale  For more information on how to obtain these programs  please    visit http  Awww elane net or send email to onlinesales xiamentech com                 rt  With nothing on the platform  press WA key  s  will  appear briefly in the LCD window as the scale Ton a self   check zeroing routine  After which 0 00z  or Og  will appear in the LCD  window  Your scale is now ready to weigh  If you use the adapter or USB  power  simply leave the scale always ON for best performance        Error Messages       Scale is overloaded       Me Low battery indicator  Please replace the battery as soon as  possible  Operation with low battery is possible but the accuracy of the  scale is affected     lf the scale displays some numbers after startup and cannot proceed to  normal weighing mode  the scale might have been overloaded and it  requires recalibration  Please see next section on how to calibrate the  scale                 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
"取扱説明書"  COMUNE DI SAN GIORGIO JONICO - Comune di San Giorgio Ionico  latest PDF - Read the Docs  - Alientech    Copyright © All rights reserved. 
   Failed to retrieve file