        Installation Manual - E2S Warning Signals
         Contents
1.                                                                                                                                                                                      1  On operated unit  twist push button  anticlockwise 55      2  Button should pop  up and twist back to  original position   to reset    Note  use alignment  marks circled to  indicate the push  buttons  status position                   Unit currently shown  as    standby  condition                      Resetting an operated unit is the same as resetting  a tested unit     European Safety Systems Ltd  Impress House  Mansell Road  Acton  London W3 7QH    Document D154 00 101 IS Issue 2 13 06 12     22s    warning signals    GNExCP6A PB    Manual Call Point     Push Button  For use in Flammable Gas and  Combustible Dust Atmospheres                                               1       Introduction   The GNExCP6A PB is a push button manual call  point which is certified to the European and  International Gas and Dust standards  The unit  meets the requirements of the ATEX directive  94 9 EC and IECEx scheme     The call point can be used in hazardous areas  where potentially flammable gas and dust  atmospheres may be present     The GNExCP6A PB has no monitoring resistors   The units are Group II  EPL  equipment protection  level  Gb  The equipment is certified    Ex e d IIC T6  Gb    and as such may be used in Zones 1 and 2  with flammable gases and vapours with gas groups  IIA  IIB  amp  IIC and t
2.  no  major technical changes affecting the latest technical knowledge for the products listed above  Content of   IEC 60079 0 2007 is identical to harmonized standard EN 60079 0 2009  content of IEC 60079 18 2009 is identical to  harmonized standard EN60079 18 2009    On behalf of European Safety Systems Ltd     declare that  on the date the equipment accompanied by this declaration is  placed on the market  the equipment conforms with all technical and regulatory requirements of the above listed  directives        Martin Streetz Date and Place of Issue  London  04 07 2012    Quality Assurance Manager Document No  DC 043 Issue_B   Telephone   44  0 20 8743 8880 European Safety Systems Ltd  Facsimile   44  0 20 8740 4200 Company Registration No  2763350  E mail  sales e2s com Registered Office  Impress House    www e2s com Mansell Road  London  UK  W3 7QH  UK    
3. When wiring to Increased Safety terminal  enclosures  you are only permitted to connect one  wire into each way on the terminal block  unless a  pair of wires are crimped into a suitable ferrule   Wire sizes allowable are 0 5sqmm to 4 0sqmm    The terminals are only permitted to be wired with  cable in an ambient temperature range of between   10  C to 80  C  All terminal screws  used or  unused  must be fully tightened down     Leads connected to the terminals must be  insulated for the appropriate voltage and this  insulation must extend to within 1mm of the metal  of the terminal throat     8  Testing unit operation  The push button unit can be tested without the  need to replace any element     To test  lift the cover lift flap to reveal the push  button  The button should be pressed into the body  to activate the unit and place it into the operated  condition                                               The call point switch will now change over its  contacts to operate the alarm     Once testing is complete the unit needs to be reset  from the operated condition     Rotate the push button anticlockwise by an angle  of 55    see guide alignment marks on the button  and cover  shown below  1   The push button  should pop back up to its original position     Ensure that the push button has also twisted back  clockwise by 55   to its original position see guide  marks on button and cover  shown below  2   The  unit is now reset                                              
4. e are 3 off cable entries for M20x1 5 Ex e  approved cable glands or stopping plugs with a  minimum ingress protection of IP66     The unit can be wired in a number of different ways    depending whether normally open or normally  closed contacts are required     Sheet 2 of 2    Single microswitch units   M S 1             ia  mi  6    ee oem          R Y B                                              M S 1  Unit in    Standby  condition    unoperated  Terminal   2 3   amp   6   switch contacts closed  Terminals   2 3   amp    4 5   switch contacts open    Double microswitch units     M S 1 M S 2                                                    M S 1 M S 2    Unit in    Standby  condition    unoperated  Terminal   1   amp   3   Terminal   4   amp   6  switch  contacts closed   Terminals   1   amp    2   Terminals   4   amp    5   switch contacts open                           j                                                    M S 1  Unit in    Operated condition        button pushed in    microswitch contacts changed  over   Terminal   2 3   amp   6  switch  contacts open   Terminals   2 3   amp    4 5  switch  contacts closed                                                    M S 1 M S 2    Unit in    Operated condition      button pushed in   microswitch contacts changed  over   Terminal   1   amp   3    Terminal   4   amp   6  switch  contacts open   Terminals   1   amp    2   Terminals   4   amp    5  switch  contacts closed    sales e2s com Tel   44  0 208 743 8880  
5. emperature classes T1  T2  T3   T4  T5 and T6     These units are also Group Ill  EPL Db  The  equipment is certified    Ex t IIIC T60  C Db    and as  such may be used in Zones 21 and 22 for  combustible dusts groups IIIA  IIIB  amp  IIC     Sheet 1 of 2    INSTRUCTION MANUAL    GNExCP6A PB Push Button Manual Call Point  ll  ee Saeed le       2  Marking  All units have a rating label  which carries the  following important information      Unit Type No    GNExCP6A PB Manual Call Point    Input Voltage   AC voltage 250V Max Current 5 0A Max  DC voltage 50V Max Current 1 0A Max    Code    Ex ed IIC T6 Gb  Ex t IIIC T60   C Db  IP66       40  C  lt   Ta  lt    55  C    Certificate No    SIRA 09ATEX3286X  IECEx SIR 09 0121X    Epsilon x  Ex  Il 2GD    CE Marking  Notified body No       0518    Year Serial No  i e  12 1 CP6APBO000001    WARNING   DO NOT OPEN WHEN AN  EXPLOSIVE ATMOSPHERE MAY BE PRESENT    3  Type Approval Standards   The call point has an EC Type examination  certificate issued by SIRA and have been approved  to the following standards      IEC 60079 0 2007   EN 60079 1 2004   IEC 60079 1 2003  EN 60079 7 2007   IEC 60079 7 2006  IEC 60079 18 2009    EN 61241 1 2004   IEC 61241 1 2004  The equipment is certified for use in ambient    temperatures in the range  40  C to  55  C and shall  not be used outside this range     sales e2s com Tel   44  0 208 743 8880  www e2s com Fax  44  0 208 740 4200    4  Installation Requirements   Installation of this equipment sha
6. ll only be carried  out by suitably trained personnel in accordance  with the applicable code of practice e g    IEC 60079 14 EN 60079 14    A  Repair of this equipment shall only be carried  out by the manufacturer or in accordance with the  applicable code of practice e g  IEC 60079 19 EN  60079 19     B  The certification of this equipment relies on the  following materials used in its construction     Enclosure  GRP   Glass Reinforced Polyester    Through enclosure mechanism  Plastic Nylon Zytel  Injection Moulded    Sealing of enclosure and mechanism  O ring  Acrylonitrile Butadiene Rubber    If the equipment is likely to come into contact with  aggressive substances  then it is the responsibility  of the user to take suitable precautions that prevent  it from being adversely affected  thus ensuring that  the type of protection is not compromised        Aggressive substances      e g  acidic liquids  gases  or solvents that may affect polymeric materials        Suitable precautions      e g  regular checks as part  of routine inspections or establishing from the  material   s data sheet that it is resistant to specific  chemicals     Refer to certificates SIRA O9ATEX3286X and  IECEx SIR 09 0121X for special conditions of safe  use     Under extreme conditions the unit may generate an  ignition capable level of electrostatic charges  The  unit must not be installed in a location where it may  be subjected to external conditions  such as high  pressure steam  which may cau
7. se a build up of  electrostatic charges on non conducting surfaces   Cleaning of the unit must only be carried out with a  damp cloth     5  Call Point Location and Mounting  The location of the call point should enable ease of  access for operation and testing  The unit should    be mounted using the 4 off fixing holes which will  accept up to M4 sized fixings   90 0                      Hen       View of base unit showing fixing centres  in mm      To gain access to the mounting holes in the base  the front cover must be removed   This is achieved by removing the 4 off M4 cap  head bolts holding on the cover                                                  down out of the way to gain access to the Ex e  terminal block  the internal earth terminal and  mounting hole recesses     European Safety Systems Ltd  Impress House  Mansell Road  Acton  London W3 7QH    Document D154 00 101 IS Issue 2 13 06 12       6   Earthing   The unit has an internal earth terminal    It is recommended that a cable crimp lug is used  on the earth wires    The internal earth wire is placed under a earth  clamp which will stop the cable twisting  This is  secured by an M4 screw and spring washer                                               ONO Lh                                              Oac I                                                                               On Sze                                            Internal Earth Ex e terminal block    terminal    7  Cable connections   Ther
8. www e2s com Fax  44  0 208 740 4200    EC DECLARATION OF CONFORMITY    v2       Manufacturer  European Safety Systems Ltd   Impress House  Mansell Road  Acton   i  London  W3 7QH  UK warning signals  Equipment Type  GNExCP6A BG  GNExCP6A PB  GNExCP6A PT     GNExCP6B BG  GNExCP6B PB  GNExCP6B PT    Directive 94 9 EC  Electrical and Mechanical equipment for use in explosive atmospheres  ATEX       Notified Body for EC type Examination  Sira Certification Service  Notified Body No   0518  Rake Lane  Eccleston  Chester CH4 9JN  UK    EC type Examination Certificate  Sira 09ATEX3286X    Notified Body for Quality Assurance Notification  Sira Certification Service  Notified Body No   0518  Rake Lane  Eccleston  Chester CH4 9JN  UK    Quality Assurance Notification  SIRA 05 ATEX M342  Provisions fulfilled by the equipment  Il 2 GD  Ex e d IIC T6 Gb    Ex t IIIC T60  C Db    40  C  lt  Ta  lt   55  C  or  Il 2 GD   Ex e d mb IIC T4 Gb  Ex t IIIC T80  C Db    40  C  lt  Ta  lt   50  C     Standards applied  IEC 60079 0 2007 Ed  5  EN60079 1 2004  EN 60079 7 2007  IEC 60079 18 2009 Ed  3  EN 61241 1 2004    Directive 2004 108 EC  Electromagnetic Compatibility Directive  EMC       Standards applied  EN 61000 6 1 2007  EN 61000 6 2 2005  EN 61000 6 3 2007  EN 61000 6 4 2007    The standards EN 60079 1 2004 and EN 61241 1 2004 are no longer harmonized  The requirements of these standards  have been checked against the harmonized standards EN 60079 1 2007 and EN 60079 31 2009 and there were
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Nokia 1506 RH-128 L1L2 Service Manual  Massive Other 30189/17/10  Carlos Henrique Ribeiro Massote  Nicolas (Georges) - Inventaires des Archives cantonales vaudoises  取扱説明書 ピストンバイブレータ NTK シリーズ  Pour une bonne Hygiène alimentaire en accueil collectif de mineurs    Personal Climber  Programming Wand Instructions  Whirlpool Refrigerator WRS325FNAM User's Manual    Copyright © All rights reserved. 