Home
        - Racepak Data Systems
         Contents
1.           Terminator Cap    VNET  T   9       FRONT FIREWALL    IM CABLE 72           G2X PRO                   REAR FIREWALL                                           IM CABLE 48        REAR  TWO SHOCK  TWO RIDE HEIGHT BULKHEAD        gt   Typical wiring diagram for Drag Racing     EGT 1 3 5 7 EGT 2 4 6 8    ENGINE    Vnet  Terminator Cap    N    RUNI FRONT FIREWALL    DATA LOGGER    A D                                      Ol    O      DASH OR GAUGE  3  O O    UDX  103 DASH OR INTELLI GAUGE                                                       DATA LOGGER  POWER   GROUND   ENGINE RPM   START LOGGING BUTTON    CLUTCH  Vnet     gt     Terminator Cap    TRANSDUCER BOX      OIL PSI     FUEL PSI    VACUUM    BLUE INDICATES VNET CABLES          Analog  This term simply refers to a sensor or signal having a large number of potential values  For instance   a water temperature sensor is an analog sensor as the output of the sensor varies continuously with the  temperature  This type of sensor is also called a voltage output sensor  Pressure  temperature  vacuum  linear  and rotary travel  would all be examples of analog channels     Data Cartridge  A small rectangular device used to transfer data from the onboard data recorder to a PC  without connecting a serial cable between the two  It is used just like you might use a floppy disc to transfer  files from one PC to another     Data Recorder  The onboard hardware device that collects and stores the information transmitted from the 
2.         680 CA PWR CLA  Power RPM  Pigtail Extension Only                680 CA PWR WPT  Serial Cable            0cc eee 680 CA SR G2X  Dash Extension  6      000n eee 680 CA EXT 5P72  Second RPM  15     Used with 800 SS MSC 3 sensor               680 CA RPM 4P15  Memory Card              c err rrr rr mnn CARD MEM CF128M  Cables and Components  Ge X Pro  V Net Module           cr rrr rh RR RR Rb bb num 230 VM 4ANA7HR  Serial Cable    iii ee eee 680 CA SR G2XP  Cable  Turck Molex  192              cere nnn nnn 680 CA TKM 192  Cable  Turck Packard  192           ssssssssssio 680 CA TKP 192  Turck Cable Connector                      cfn 800 CN 5143F  Bulkhead Connector  5 volt out                  280 BH 4ANA 5  Bulkhead Connector  12 volt out               280 BH 4ANA 512  Memory Card  128MB              ssssssisci  o CARD MEM SD128  Cover Plug  Memory Card                       800 SD COVER          RED HOUSING  None Required  ANTG ANN 05  680 CA PWR R4P  680 CA PWR R4P  680 CA PWR R4P  280 CA ST140SR    680 CA RPM R2  890 SDWC 2GB                  www RACEPAK com       V Net modules and Interface modules  although similar  in construction and appearance  are very different in the  functions they perform  It is important that components  designed for one system not be interchanged with  the other  V Net cables use a 5 pin connector  while  Interface cables use a 7 pin connector  So that cables  can be identified at a glance Racepak has color coded  the connectors on the end o
3.         TEMPERATURE  continued    Exhaust Gas Temperatures Cylinder Bank Sets   EGT  Junction Box  amp  4 Probes  1357  Small Block     220 VP TC 1357S  EGT  Junction Box  amp  4 Probes  2468  Small Block    220 VP TC 2468S  EGT  Junction Box  amp  4 Probes  1357  Big Block         220 VP TC 1357B  EGT  Junction Box 8 4 Probes  2468  Big Block    220 VP TC 2468B    EGT  Junction Box  amp  4 Probes  1234              220 VP TC 1234  EGT  Junction Box  amp  4 Probes  5678              220 VP TC 5678  EGT  Junction Box  amp  4 Probes  Motorcycle        220 VP TC 1234M  EGT  Junction Box  amp  3 Probes  123                220 VP TC 123  EGT  Junction Box  amp  3 Probes  456                220 VP TC 456  EGT  Junction Box  amp  3 Probes  135                220 VP TC 135  EGT  Junction Box  amp  3 Probes  246                220 VP TC 246    The EGT junction box sets are ordered by the cylinder bank sequence they serve     Exhaust Gas Temperatures Single Cylinder    Single cylinder modules include the thermocouple      EGT  Cylinder  1       nnn e nem 220 VP TC EGT1  EGT  Cylinder  2             c rrt nh rnm 220 VP TC EGT2  EGT  Cylinder Z3                rrr nnn nm 220 VP TC EGT3  EGT  Cylinder Z4               RER RRE nnn nm 220 VP TC EGT4  EGT  Cylinder  5            nme 220 VP TC EGT5  EGT  Cylinder Z6     00cce eee 220 VP TC EGT6  EGT  Cylinder Z7              ccr nnn nnnm nmn 220 VP TC EGT7  EGT  Cylinder  8                rrr nn n nn 220 VP TC EGT8    Thermocouple Only   187 
4.     830 WS ALTPAPC2       Altronics PerformairePC Monitors  Altronics PerformairePC Calculates     Temperature Air Density Ratio  Relative Humidity Dew Point  Absolute Pressure Correction Factor  Vapor Pressure  Grains of Water  Density Altitude    Oxygen  Optional   Oxygen Altitude  Optional   Wind Speed  Wind Direction       NHRE FULL  fw               Sweatshirts   Our black long sleeve sweatshirts with elastic crew neck collar and cuffs keep the cold  out and the warmth in  A small embroidered Racepak logo on the front and a larger  version on the back tells everyone that you are there gathering some serious data        Sweat Shirt  Black  Large                      880 PM SSBK L  Sweat Shirt  Black  X Large                  re 880 PM SSBK XL  Sweat Shirt  Black  XX Large                  880 PM SSBK XXL    Cap   Your racing cap collection won t be complete until you have added this good looking  black cap with embroidered Racepak logo to yours  An adjustable band means one  size fits all     Cap wc ene ee meee 880 PM CAP    Tee Shirts    Dazzle your friends and intimidate your competitors by letting them know you are  plugged into the world of data acquisition  These heavy duty black cotton Racepak  Tee Shirts feature a small silk screened Racepak logo on the front and a larger  version on the back     Tee Shirt  Black  Medium                         880 PM MTBK M  Tee Shirt  Black  Large                 erre 880 PM MTBK L  Tee Shirt  Black  X Large                      
5.     NPT male pipe fitting           0 15 Pola cei SCR er ea 810 PT 0015GVT  O75 PS   sua eee d MCN P6 C ba 810 PT 0075GVT  0 150 PSl 4 234  cinte i rr 810 PT 0150GVT  0 300 DSI ski see ERR ee 810 PT 0300GVT  Je  CC  WEE 810 PT 0500GVT  0 1500 BSE 1x23 9A 6 ACOCOEOR ea ea ea AA 810 PT 1500HP  0 3000 PSE ice 4X AA KAAWAAN CC AA ORC 810 PT 3000HP  VACUUM PRESSURE SENSOR pei Sancor  30 In  hg 0 30 psi  Vacuum Boost                       810 PT VB    ADAPTER MODULES    The pressure sensors listed on page 19 can be adapted to the V Net cable or analog port of the recorders by using the appropriate  signal condition module     V Net Module  see page 17                 rrrnrrrr 230 VM PT 5V  For connection to the V Net cable on V series recorders   Interface Module  see page 23                    240 IM PT 5V    For connection to the Analog port on V series recorders     Fuel Flow Meter Sensors    Monitoring pressure to evaluate your fuel system will only give you half of the picture  To know the exact status of how it is affecting  your engine you must also know the fuel volume  These general purpose turbine type flow meters require an available digital channel    Gasoline and Nitro methane flow meters are constructed of aluminum  Methanol fuel requires the use of a stainless steel flow meter  A  tee fitting must be used so all fuel can be routed through the flow meter before it is divided between the hat nozzles and the port nozzles  on fuel injection applications        Flow Meter
6.    DATA ACQUISTION   PERFORMANCE INSTRUMENTATION   VEHICLE WIRING  MASTER CATALOG       3 E  lt            M     v  J       Racepak Data Systems was founded in 1984 to design and build affordable  and reliable onboard data acquisition equipment  As Racepak built and refined  its early data acquisition systems  the equipment found its way into many  forms of motorsports before finally catching the attention of the drag racing  community  Though there had been previous attempts to construct data  recorders for Top Fuel and Funny Cars  none had proven reliable  Racepak  knew that if they could develop onboard data acquisition that could survive  in this hostile environment  that it would survive anywhere  By achieving this  goal  the Racepak data recorder was established as the clear choice in data  acquisition  The result is that Racepak can now be found on nearly every  professional drag racing vehicle competing throughout the world    Racepak has reinvested heavily into supporting the quest for information  technology  The Racepak line has now grown to include a large selection  of unique loggers  software  gauges  and ancillary equipment  for use in a  variety of motorsports  This has positioned the company as a leader in the  data acquisition industry  and expanded our clientele to include industrial  applications  OE manufacturers  and testing facilities  as well as a broad  spectrum of land  water  and snow based motorsports  In 2005  Racepak  was acquired by MSD Performa
7.    ID  2 1 8       wae 800 CL 8M 2125  8 Magnet  2 187    ID  2 3 16                  Leer 800 CL 8M 2187  Collar is attached MEASURE YOKE Sensor  with two bolts pet O D  HERE      U J oint Yoke       Split Collar and Sensor Kits   The following kits are provided to aid in monitoring the revolutions of a shaft  or as  replacement sensors and split collars for the recorders indicated  They include the  sensor  bracket and the split collar with magnets                                                    Uses sensor Uses sensor Kit replaces the old obsolete brass   800 SS PRO5  V300 V500   800 SS RB 5 sensor and 7 8    diameter single magnet     800 SS MSC 5  V300SD  Uses a  800 SS RB 5 sensor  Split Collar  800 KT 2MP 175 Sensor Kit  800 KT 2MP 181 800 KT 2MR 181 800 KT 1MR 181  800 KT 2MP 187 800 KT 2MR 187 800 KT 1MR 187  800 KT 2MP 212 800 KT 2MR 212 800 KT 1MR 212  800 KT 2MP 218 800 KT 2MR 218 800 KT 1MR 218       Magnets   These are the rare earth magnets that are currently used in the clutch input shaft  the split collars  shown above or with some front wheel RPM applications  Each magnet measures  250    OD x  200     in length  North end of magnet is painted yellow for easy identification   Magnet Only  Rare Earth  Single                 800 MG SM  25       Rare Earth Magnet             Torque   Horsepower Sensor  This Torque   Horsepower sensor is a true on vehicle dynamometer system that  measures Torque and RPM while you drive to deliver Horsepower numbers that can b
8.    L  X 4 000     W  X 1 125     deep    18 41cm X 10 16cm X 5 39cm     Weight   1 Ib   453g     103 Display    Remote mount programming buttons for IQ3 dash  Includes two buttons  wiring and connectors    Programming buttons                  280 SW IQ3BTN    I3 Mounting Panels   Trim to fit  vacuum formed plastic mounting panel    Faux Carboni    isa   X Rma cs x RC RR 800 MB IQ3 PCF  Black qc                 car 800 MB IQ3 PBLK  SINCP Lis GWEN NEE EN ae ae a 800 MB IQ3 PAL        949  709 5555           INSTRUMENTATION       UO Papa        e  D  ea    DISP    Given the popularity of replay and recall gauges  the UDX Replay Dash  goes one step further by providing the ability to replay up to 10 minutes of  data  while also functioning as full feature LCD display dash    The UDX Replay Dash includes a wire loom and sensors for engine RPM   water temperature  oil pressure and battery voltage  Sensors for displaying  other sensor inputs must be purchased separately     Replay Model  Display  amp  Replay             250 KT UDXRP    UDX Mounting Panels    Trim to fit  vacuum formed plastic mounting panel     Faux Carbon                ccoo RR RE RR 800 MB UDX PCF  Ei EE 800 MB UDX PBLK  Silver wo  eee aan anan 800 MB UDX PAL          MODE                 FEATURES    Specifications    Display up to 21 sensor inputs via 4 pages   Adjustable backlighting   User defined warning lights  Minimum Maximum recall    Includes    UDX Replay Dash   Water temperature sensor   Oil pressure sen
9.   9   18  and 36       949  709 5555       CLOSED  COURSE          The new IQ3 merges Racepak   s V Net single cable sensor technology and  proven GPS based data logging with a fully programmable display  creating  a complete data center    The full feature dash includes an internal 32 sensor channel data logger   while track mapping and speed is obtained by the internal GPS board and  3 axis G meter thus eliminating the need for an external data logger  beacon  receiver and wheel speed sensor  No sensor wiring harness is required  as all  external sensor data is routed to the rear of the dash by a single V Net cable    The Datalinkll software included with the IQ3 dash provides professional  level data analysis capabilities  but in an easy to learn format    IQ3 Logger Dash enk Ka bb bb bm 250 DS IQ3LD    The LDX Logger Dash package includes     IQ3 Data Logger Dash   Power Ground Engine RPM Remote Programming harness  Rear V Net connector GPS antenna connector   512mb microSD memory card   GPS antenna and cable   Programming cable   Datalinkll software and installation manual    I3 External Programming Buttons   Remote mount programming buttons for IQ3 dash  Includes two buttons   wiring and connectors   Programming buttons                  280 SW IQ3BTN    IQ3 Mounting Panels    Trim to fit  vacuum formed plastic mounting panel     Faux Carbon               800 MB IQ3 PCF  Black 220G bk ORE een 800 MB IQ3 PBLK  Silver                rene 800 MB IQ3 PAL  IQ3 Mount       CNC
10.   Gas or Nitro   8AN  1 10 GPM         800 FM AN8 AL  Flow Meter  Gas or Nitro   10AN  2 25 GPM       800 FM AN10 AL  Flow Meter  Gas or Nitro   12AN  2 70 GPM       800 FM AN12 AL  Flow Meter  Methanol   8AN  1 10 GPM            800 FM AN8 SS  Flow Meter  Methanol   10AN  2 25 GPM          800 FM AN10 SS Flow Meter for Methanol    Additional flow meter types and rates available on special order   Flow Meter Tee Fitting   10AN inlet  two  8AN outlets    800 FM TEE       ADAPTER MODULES   V Net Module    rh nnn 230 VM FLOW Flow Meter Tee  Use to connect flow meter to V Net cable    Interface Module    aen nee eee 240 IM FLOW    Use to connect flow meter to digital port of V300 or V500 if no digital wiring harness is being used        DRAG       RPM  REED SWITCH SENSOR     These contact closure type sensors use an internal  fast acting reed switch to indicate  the passing of a rotating magnet   RPM Sensor  2 Pin  5 16    24 dia                   800 SS PRO 5  Commonly used as a driveshaft RPM sensor on pre 2001 clutch RPM sensor with Pro  Series recorders   RPM Sensor  2 Spade Connectors  5 16    24 dia        800 SS RB 5  Commonly used for clutch  driveshaft and front wheel RPM with SC1000 recorders     ZERO CROSSING SENSORS    Zero Crossing RPM Sensor  3 Pin  3 8    Dia            800 SS ZX 3    This non powered sensor is designed for monitoring magnetic pulses  It must be Zero Crossing RPM Sensor   used with an RPM input designed for a zero crossing sensor  Used as the clutc
11.   If desired  they can also be attached to the  analog port by using an Interface module rather than a V Net module  These sensors  are designed for use in measuring distances ranging from 3 93 to 15 75 inches  Each  sensor must be used with the appropriate V Net module     Ride Height Sensor Kit  V Net  Left Front        220 VP RIDEHTLF  Ride Height Sensor Kit  V Net  Right Front      220 VP RIDEHTRF  Ride Height Sensor Kit  V Net  Left Rear        220 VP RIDEHTLR  Ride Height Sensor Kit  V Net  Right Rear       220 VP RIDEHTRR  Kit includes V Net module  amp  sensor  Please specify position   Module Only  Ride Height  V Net  Left Front         220 VM RHBLF  Module Only  Ride Height  V Net  Left Rear         220 VM RHBLR  Module Only  Ride Height  V Net  Right Front       220 VM RHBRF  Module Only  Ride Height  V Net  Right Rear       220 VM RHBRR  Sensor Only  Ride Height        00000cne eens 810 SN RHB    G force Sensors  Accelerometer    For years  engineers and enthusiasts have been measuring the longitudinal and  lateral forces of a vehicle as a method of evaluating its acceleration  braking  or  handling performance  You can do the same with these G meters  These G force  sensors can be adapted to any V Net system  Note  V300  amp  V500 data recorders all  contain internally mounted G meters   The externally mounted G meter measures  2 0    x 2 0    x 1 250        G Meter  0 6G     c eee 220 VP GM  ADAPTER MODULE  V Net Module Only                           rr 230 VM A
12.   Longitudinal g meter  acceleration and deceleration   Lateral g meter  side to side motion   GPS    Dimensions   9 6   L  X 4 00   W  X 1 5     H    14 2cm X 10 16cm X 3 81cm     Weight     Logger  13 oz    37 kg   Kit  1 Ib  13 oz    81 kg     G2X GPS       The G2X GPS package includes     G2X Recorder   GPS Antenna   LED Dash Display   SD Memory Card   Datalink Il Software   Communication Cable   Cigarette Lighter Adapter  Power Ground Engine RPM Harness    www RACEPAK com                       p d pp    a H    Zo AC  gt   SS      UNOH KAN TIMKEN  MAHLE p    4 A   z   e    Em    net CS      ML was MSO D m ser piast  5 CV Mobilm  CET S 3M Eo M32   gt  mop le        home TO V A pu ETS ND  MAMA    When Racepak introduced their series of V Net  data loggers  which allows all sensors to transmit  their data back to the data logger via a single cable   the next logical progression in this technology was to  add the ability to plug gauges and dashes into this  same V Net cable  By doing so  this would allow the  gauge to share the sensor information with the data  logger  thus providing a true    vehicle network    of data  logger  sensors and gauges  all routing their data  through a single cable  This design has proven to be  tremendously popular  as the installation  weight and  complexity of data systems and related components  was greatly simplified        Taking this design a step further  this line of    Intelli   Gauges    and LCD Digital Display Dashes could now  use th
13.   SmartWire Switch Module                            500 SW 5MI6   Switch Panel Mount Brackets                         500 MB SPxxxx  Available sizes are  1 50     1 625    and 1 75      SmartWire to Switch Panel Cable                      580 CA BN5P xxx  Variety of sizes offered    SmartWire to V Net Cable                             280 CA BN5P xxx  Available sizes are  9   18  and 36       949  709 5555       DATA RECORDERS       J      VED A FEATURES  A        DATA RECORD       Channels    67 total   V Net  56   Analog  4 hard wired  Digital  4 hard wired  Internal  3    meng    po madi    Sample Rates    V Net  up to 100 per second   Analog  up to 1000 per second   Digital  RPM and switch contacts up to 100 per  second    ae    Memory    SD memory card   Recording time depends on number of  channels monitored and sample rates  Record multiple runs    The V300SD series data recorder is our most popular data recorder  In es  base configuration  the V300SD monitors five parameters  but it can be Internal Sensors   expanded to monitor up to 67 channels of data to meet the needs of most Battery Voltage  users  The V300SD can sample data as quickly as 1000 times per second  Longitudinal g meter  acceleration and  Uploading recorded data to your computer IS done viaa SD memory card  ET  side to side motion   which provides you with hours of recording time and the ability to store  many runs prior to uploading the data  This means that no download cable Dimensions   is required
14.   The G2X Pro contains a standard V Net port  along with one 4 input RPM port and two analog input ports  analog 1 4 and analog  5 8  This design allows the customer to connect up to 56 Vent sensors to the V Net port  using our standard V Net cables as found on  page 27 of this catalog  In addition  up to 8 total analog sensors may be connected to the Analog ports  4 sensors through 1 4 and 4  sensors through 5 8   Three additional RPM inputs may be connected to the RPM 1 4 port  The 8 analog inputs provide logging rates  up to 500HZ  Racepak has created the following sensor packages for use with the G2X Pro    1  Steering Throttle Brake Brake PN  600 KT STBB   2  Four Shock Package PN  600 KT 4SHOCK   3  Four Ride Height Package PN  600 KT RIDEHT    A schematic is provided on page 46 of this catalog  displaying a typical installation utilizing a G2X Pro and the above sensor packages     I3 Logger Dash    The IQ3 logger dash contains a standard V Net port on the rear of the dash  allow up to 32 sensors to be connected to the dash   using our standard V Net cables as found on page 27 of this catalog  Sensors can be added to the IQ3 using the information found  at the top of this page           Typical wiring diagram for Circle Track Road Course     FRONT  TWO SHOCK  TWO RIDE  STEERING  THROTTLE  BRAKE 1  BRAKE 2 BULK HEAD HEIGHT BULK HEADS    N               VNET CHANNEL  HIGH RES BULKHEAD    DASH CABLE 36     Vnet  Terminator Cap    IM CABLE 72       IQ3  G2X OR UDX    Vnet  
15.   The V300SD also has multiple methods of displaying monitored 4 374     L  X 3 935   W  X 1 230     H   data in real time  When linked by serial cable to your PC you can view all  11 11cm X 9 994cm X 3 12cm   recorded functions in either graph format or on 8 virtual gauges while the Weight   vehicle is running  Any monitored function can also be displayed in real 10 ounces   28 kg     time on Racepak s optional Intelli Gauges  UDX dash or IQ3 display dash     Also  the V300SD can monitor overall ignition timing with the optional timing VW E     O     D  package  See page 24 for more information           Typical Uses  The V300SD package monitors  The V300 package includes   Pro Mod Engine RPM V300SD Data Recorder  Pro Stock Driveline RPM SD memory card  Top Dragster Engine v  Driveline RPM differential Driveshaft or rear wheel RPM sensor with split collar and magnet kit  Top Sportsman Battery voltage Datalink software kit with serial programming cable  Comp Eliminator Acceleration g force V Net tee connector with terminator caps  Super Comp Lateral g force Power Ground Engine RPM Driveshaft Harness  Super Gas  clutch RPM optional upgrade   Motorcycles  Land speed cars  Drag Boats  V300 V300SD Recorder Mounting Brackets   for 1 250  O D  tubing                       800 MB V300 125  V300 V300SD Recorder Mounting Brackets   for 1 500  O D  tubing                      800 MB V300 150  V300 V300SD Recorder Mounting Brackets   for 1 625  O D  tubing                      800 MB V3
16.   Weight   21 ozs    58 kg     UDX Display          Specifications    Display up to 28 inputs via 4 pages   Blue backlight   Gear Indicator   Eight user defined alarms with on screen warning  text and lights   User defined 5 character sensor input names  User defined shift lights   shielded  low luster display for sunlight viewing  Metric and English capable    Dimensions   7 25     L  X 4 000   W  X 1 125   deep    18 41cm X 10 16cm X 5 39cm     Weight   1 Ib   453g     103 Display    Remote mount programming buttons for IQ3 dash  Includes two buttons  wiring and connectors    Programming buttons                  280 SW IQ3BTN  I3 Mounting Panels    Trim to fit  vacuum formed plastic mounting panel     Faux Carbon iia BUENA LN EG EG 800 MB IQ3 PCF  Blackie 23x 29 25 eee sak 8 mis 4  NOR andi EURO E 800 MB IQ3 PBLK  SING pulizie TIT 800 MB 1 3 PAL       www RACEPAK com          INSTRUMENTATION       INTELLIGENT GAUGES  These are not your average     analog or digital gauge  They are both  In addition  they  SEA V ES are highly accurate  stylish  dependable  and provide  zo Ap    d real time display for your monitored functions     ISYNOI  035019    an  ea is WARNING ALARM  Intelli Gauges can act  as a watchdog  Each gauge can monitor user   programmable minimum or maximum limits and flash  the digital display  and or a remote light  when either    threshold is exceeded        Racepak s Intelli Gauges are the best way to relay pertinent engine and  drivetrain information when 
17.   sete soe ENEE EE e ENEE E EU RES 680 CA SR G2XP  Serial Cable  G2X black  Bi  680 CA SR G2X  Serial Cable  UDX Dashes  Bi    280 CA SR UDX  Serial Cable Extension   Used to extend length of above cables   25                 890 CA DB9X 025  USB Adapter  SErial to USB Port  For PC   s that do not have a Serial Port             890 CA USB2SER  USB Cable Extension   For PC s that do not have a Serial Port                        890 CA USBAA 6    SD  amp  Micro SD Components    SD   Micro SD USB Card FEELEN rd Aer ame 890 SD RDR 5  SD Memory Card  V300SD  Sportsman  G2X  G2X Pro                              890 SDWC 2GB  Micro SD Memory Card  IQ3    siii a dee ee ee 890 SD M2GB  Cover Plug  for SD Memory Card    ee rn nnn 800 SD COVER    Memory   Eliminate the memory cartridge and USB to cartridge reader with this kit  Data is  downloaded transferred to users PC via a commonly available SD memory card   For use with Racepak V Net data loggers utilizing memory cartridge download   Memory Cartridge to SD Card Adapter                 890 KT CARTSD                fi K N a  A i       SIS Camera Systems    Re PlayXD  Smallest POV video system available  Camera  recorder   memory card and battery all housed inside  75    x 2 75    billet aluminum  camera housing  Includes camera  battery and memory card  Optional  mounts and extended battery available     Re PlayXD Li    840 REPLAYXD  Re PlayHD  1080                            840 RPLYXD 1080    Chasecam Start Record Module  Sync Race
18.  10 2     W  X  75    deep      Requires 2  rear clearance    10 16cm X 25 90cm X 1 90cm     Weight   21 ozs    58 kg     133415    UDX Display          Specifications    Display up to 28 inputs via 4 pages   Blue backlight   Gear Indicator   Eight user defined alarms with on screen warning  text and lights   User defined 5 character sensor input names  User defined shift lights   shielded  low luster display for sunlight viewing  Metric and English capable    Dimensions   7 25     L  X 4 000   W  X 1 125   deep    18 41cm X 10 16cm X 5 39cm     Weight   1 Ib   4539     103 Display    Remote mount programming buttons for IQ3 dash  Includes two buttons  wiring and connectors    Programming buttons                  280 SW IQ3BTN    I3 Mounting Panels    Trim to fit  vacuum formed plastic mounting panel     Faux Carbon                    sccn nnn 800 MB IQ3 PCF  Black s isicostmanioniatia te ta siena rene 800 MB IQ3 PBLK  SG RR E AUREIS E MESE SIEG EGRE EE 800 MB IQ3 PAL     949  709 5555              Ny      1 a    NG Y    EFI Data Interface    These V Net modules have been created to interface with many electronic fuel injection systems on the market  Each V Net  EFI Data Interface module is equipped to allow direct connection with EFI  These modules allow your V series data recorder to  share the data collected by these systems rather than having to install duplicate sensors to monitor functions that are already  being monitored by the EFI system  The shared data can be recor
19.  220 VP WOTEVENT    Clutch Event  12 volt Triggered    Monitors two step clutch pedal switch       220 VP CLTEVENT       Engine RPM Input             EFI Data Interface    These V Net modules have been created to interface with many electronic fuel injection systems on the market  Each V Net  EFI Data Interface module is equipped to allow direct connection with EFI  These modules allow your V series data recorder to  share the data collected by these systems rather than having to install duplicate sensors to monitor functions that are already  being monitored by the EFI system  The shared data can be recorded or displayed just as you would any function monitored  independently by your Racepak V series recorder  Caution should be exercised to ensure that you do not exceed the maximum  number of V Net channels supported by your particular logger  The individual functions monitored by each EFI system are  outlined in the chart below     For use with Racepak V Net data loggers     Autronic SMC  amp  SM2 230 VM EFIAUT  Corvette C6 OBDII GMX3  2006 and later  230 VM EFIC6  Haltech 230 VM EFIHAL  Megasauirt   230 VM EFIMSI  Omex 230 VM EFIOMEX    Vipec 230 VM EFIVIPEC  WOLF V500 230 VM EFIWOLF          Shift Light Event Module    The Shift Light Module allows you to use any LED style light  300 milliamp maximum   as a fully programmable  stand alone shift light  By accessing the engine RPM off of  the V Net you can program up to six separate shift alarm signals  Each shift point is 
20.  880 PM MTBK XL    Tee Shirt  Black  XX Large                     880 PM MTBK XXL             Adding Sensors To a GPS Based Data System    Racepak offers three types of GPS based data systems  varying in total sensor inputs and types  The following information is intended  to assist the customer when ordering sensors  Adding sensors to any of the following data loggers is as simple as    1  Determine the mounting location of the data logger   2  Determine the mounting location of the sensor V Net module s   Each sensor will have a corresponding V Net module and cable     V Net modules that are in close proximity can be connected to each other  Following this  measure from the data logger to the  closest V Net module sensor  and from each V Net module to the next  if unable to connect to each other  Round each measurement  to the closest 12      3 meter  increment  refer to page 27 of this catalog and order the appropriate V Net cable s      GeX    Black Housing   This G2X provides input for 12 external sensors  which are connected to the data logger by means of an AUX to V Net Cable PN  680 CA AUX 084   Red Housing   This G2X contains Racepak s standard V Net port  thus connecting sensors to the data logger by use of any standard V Net extension  cable  as found on page 27 of this catalog  U to 12 sensors may be added   Either version of the G2X can utilize any of Racepak s V Net sensors  in addition to the Steering  Throttle Brake Brake package  PN  600 KT STBB     GeX Pro  
21.  Available with a two or three pin Molex connector  Kit includes both a male  and female connector and pins     2 Pin Molex Connector Kit                n nnnm 810 CN MOL2  Pin Molex Connector Kit                 n nnns 800 CN MOL3  Crimp Tool  for Molex Terminal Pins            800 XP CRIMP 01F          0 75 psi       0   300   F  Temperature    3 Pin Molex  Connector    2 Pin Mole  Connector             Auto CI t  ACE K         I MM  A   2 e    A e 2 si f    A n a  el i  at re LI Iv  a     I peg PI NAN     SAKA E    M GR    r a    H   Molle    GIA  eve  FPEINA mu    Digital V Net Modules with Sensors  Pre Programmed   These pre programmed digital function modules and sensor combinations are ready for plug and play installation on the V Net  cable  See sensors only page        Clutch RPM      0cc nee 220 VP CL 1  Monitors magnetic pulses using a Zero Crossing sensor   Drive Shaft RPM  Automotive        Contact Closure Sensor                   rrr 220 VP DS 2  Contact Closure sensor  includes split collar  magnet  and bracket kit    Drive Shaft Rear Wheel RPM  Motorcycle          220 VP ZXDS 2  Monitors magnetic pulses using a Zero Crossing sensor    Front Wheel RPM                        nn nnm mmm 220 VP FWZX  Monitors magnetic pulses using a Zero Crossing sensor    Front Wheel RPM bb bb bb ERR nn nm mmm 220 VP FWHE3 Driveshaft RPM  Monitors ferrous metal pulses using a Hall Effect sensor    Turbo Speed     cence 220 P TURBORPM  for use with Racepak V Net Data Loggers   Tur
22.  Diameter  specify 18  or 27  length  Thermocouple Only   250  Diameter  specify 9   18   28  or 36  length    Analog V Net Modules without Sensors   pre programmed    These analog function modules have been programmed for general usage   and have not been assigned to a specific task  Use of these modules on the V Net  cable requires the addition of a sensor and configuration of the module using your  Datalinkll software     Voltage  0 5 Volt Input  5 Volt Output              230 VM AN 5V   Voltage  0 5 Volt Input  12 Volt Output             230 VM AN 12V   Pressure  5 Volt  see sensors page 57             230 VM PT 5V   Position Movement  Rotary or Linear                230 VM TPS   Temperature  Fluid type  0 3007F                230 VM TR 300  For use with Racepak sensor  810 TR 300 only  see page 57    Temperature  Low  0 600  F                         230 VM TC 600  For use with type K thermocouples only  see page 56    Temperature  High  0 1800  F                   230 VM TC 1800  For use with type K thermocouples only  see page 56    Air Fuel Sensor Input  Single                          230 VM AF   Air Fuel Sensor Input  4 Station              230 VM AF  cyl  s    Battery Voltage      0  cee 230 VM BVOLT   Voltage Differential bb eee 230 VM 5VDIFF   Universal Sensor Module         000000n nen 230 VM USM    4 channel programmable multi use inputs         EGT Cylinder 1    Voltage 0 5 Input    Mii    Universal Sensor Module                Analog V Net Modules with Sensor
23.  Net single cable technology  allowing for an extremely  simple installation  while providing a variety of data for  a multitude of motorsports  More information on each  system follows     Intelli Gauges   The Intelli Gauges are a great support component  of the V Net data recording systems  Their unique  capabilities and ease of installation make them  attractive for a variety of performance applications  All  of the gauges are 2 5 8    diameter and feature a full 270    sweep needle  a programmable digital display and  electro luminescent lighting  See page 16 for additional  information concerning the Intelli Gauges     ODO                 Racepak cap       The UDX is a digital display dash  capable of being utilized with any of Ra   cepak s V Net series of data recorders    With connection to the data logger via the same V Net cable utilized by the  external sensors  the UDX display is capable of    sharing    sensor data with the  data logger  thus providing the ability to display or trigger warnings based on  any internal or external sensor in use by the data logger     UDX Display         225w serio 250 DS UDX     OEE LAN DARAI       The IQ3 Display Dash can be utilized with any of Racepak   s V Net data loggers   providing a compact  fully programmable LCD digital dash for use in a variety  of motorsports    A single V Net cable is routed to the rear of the dash  providing power and  access to all sensor information transmitted to the data logger  Up to 24 different 
24.  PN  810 KT TC 500  Specify use and cable length   See sensors only on page 30    0 5 Volt Input Module           Pressure Transducer       outputs 5 volts to powered sensor              810 MD 0 5VOUT 0 5 Volt Input   0 5 Volt Input Module  Output 5 Volt  outputs 12 volts to powered sensor                810 MD 0 5    Cable Only  Sensor to either module 800 CA 3PM  specify length    Receives 0 5 volt input from powered sensor while providing 5 or 12v to power the sensor           Split Collars    These aluminum split collars provide a mounting platform for the magnets that are used to trigger the sensor when monitoring  the revolutions of a shaft  They are typically used on rear end yokes or couplers to provide driveshaft RPM  Each collar is  approximately  375    wide and houses two magnets which are located 180   apart  Custom size and dual magnet collars are  available by special order    Split Collar Only With Two Magnets             1 379 1D   1 0B aaa eee eee a 800 CL 2M 137  1 625    ID   1 5 8 aa waa ce ee KEIER CNN eee AA 800 CL 2M 162  1 812    ID   1 13 167  ossia a AA owe 800 CL 2M 181  1 8759    ID   1 Te isc ERR aa 800 CL 2M 187  2 125    ID   21 8     ue AA ewe 800 CL 2M 212  2 187    ID  231067  cxa a WANG we ee NR RER E 800 CL 2M 218  3 197  ID   3 3 10 DREES 800 CL 2M 318  3 200    ID   3 1 4    uuum eee sn 800 CL 2M 325  3 500    ID   3 1 27  EE 800 CL 2M 350 Two Magnet Split Collar  8 Magnet  1 875    ID  1 7 8       2  ee 800 CL 8M 1875  8 Magnet  2 125 
25.  Sensors   Engine RPM  Driveshaft RPM  Battery Voltage   Start Record button   2 axis G meter   12 Volt event       Containing the same hardware and software utilized by our professional  series data recorders  the Sportsman Drag Race Data Logger package offers Dimensions  i  an economical solution for the sportsman drag racer  6  X49  W  XT   H    KS i a l  15 2cm X 11 43cm X 2 54cm    Utilizing Racepak   s exclusive V Net sensor input compatibility with our full  V Net product line  while the 21 total sensor inputs  internal and external  provide Weight   the ideal balance of cost and features  allowing the sportsman racer to monitor 0 65 Ibs   information such as EGT  oil pressure  water temperature  transmission pressure   12 volt event  air fuel etc    The use of a SD memory card ensures hours of recording time and the ability  to store multiple run files  before downloading  Installation is simplified by the  use of a factory terminated wiring harness and pre progammed software        Sportsman with Datalink Lite Software              610 KT SPRTMN  Typical Uses  The Sportsman base package monitors  The Sportsman package includes   Non blown Sportsman Engine RPM Sportsman data logger  Super Comp Driveline RPM User terminated harness  Super Gas Battery Voltage Driveshaft collar  sensor  amp  mount bracket  Accel G Start record button  Lateral G SD to USB card reader  12 Volt Event USB to serial port adapter    Serial programming cable  Datalinkll software  Installation  
26.  TX CAP4    compression style fitting  Nut  amp  FerruleOnly     800 Tx NF4 O    Cylinder Head Temperature Thermocouple Assembly    800 TC MT ASM  Ring type sensor is used to monitor temperature of the metal  not the coolant     Fluid Temperature Thermocouple Assembly            800 TC FT ASM  Used where the probe can be immersed in liquid  such as in a dry sump tank   Manifold Temperature Thermocouple Assembly         800 TC MT ASM    Open end probe reacts quickly to changing temperatures in manifold plenum     Thermocouple Assembly             THERMOCOUPLE ADAPTER MODULES   V Net Module bb RER RR RR RR RR Raab bb 230 VM TC 600  Used to connect the thermocouple sensors  on previous page  to the V Net cable    Interface Module      bb cee 240 IM TC 600  Used to connect the thermocouple sensors  on previous page  to the Analog port    Pro Analog Plug In Style Transducer                 810 MD TC 500  Used to connect the thermocouple sensors  on previous page  through a Pro Analog Box     Fluid Temperature Sensors   This sensor is commonly used in conjunction with the modules shown below to measure  the temperature of fluids such as water or engine and transmission oil where the temperature  does not exceed 300  F   Fluid Temperature  Sensor Only        0 300  F  for use with V Net modules                        810 TR 300 _    0   300  F Fluid  Fluid Temperature  Sensor Only  Temperature Sensor  0 250  F  for use on Ultra Dash only                     810 TR 250  ADAPTER MODUL
27.  The  kit consists of four infrared sensors  cables and the connectors that allow you to  custom tailor the length of the cables to a Turck bulkhead connector  NOTE  Prior  installation of our Shock Travel Kit  PN 620 KT 4SHOCK  shown above  is required  as the ride height sensors share the bulkhead connectors used in the shock kit   If the Shock Travel Kit is not used you must add two 280 BH 4ANA 512 bulkhead  connectors to this kit    Ride Height Kit       0000c eee 620 KT RIDEHT    Ride  Height Kit    V NET SENSORS AND MODULES       Both the G2X and the G2X Pro recorders are somewhat unique  within the Racepak line of data acquisition systems  Although  they share many components that are also used with other V Net  recorders  the optional and replacement components shown  below can only be used with these GPS based systems    Also  there are two versions of the G2X  The original G2X   600 KT G2X  was in a black housing and a new version was  introduced in mid 2007 in a red housing  There are different  harnesses available for the two models  The components listed  here are for the original black housing design  For replacement  parts for the red housing contact Racepak at 949 709 5555     CLOSED  COURSE    ORIGINAL   Cables  Ge X BLACK HOUSING  V Net Adapter  7     Auxiliary port to V Net modules      680 CA AUX 084  GPS Antenna  5    sa AA AA AA KR n ANTG ANN 05  Power RPM  6     Hard wire into vehicle              680 CA PWR 4P  Power RPM  Cigarette lighter adapter     
28.  a USB connection to the user s PC  The design of the module functions  to both reduce overall installation weight   clutter  while providing a quicker  reacting electronic system  through the solid state switching design    Manual activation is achieved through use of an optional eight switch  Racepak Switch Panel  From the Racepak Smartwire module  a single small  cable is routed to the SwitchPanel  reducing wiring clutter  Users needing  additional switch panel capabilities can easily expand through the use of a   jumper  cable to a second Racepak SwitchPanel    The V Net compatibility insures a seamless integration with existing  Racepak data logger or displayed equipped vehicles  while also providing a  future upgrade path for additional inputs  control modules and instrumentation   when utilized as a standalone power control module    Each Racepak SmartWire Kit includes the module and connector kit        FEATURES    Capacity   125 total amps    DVd    Channels    30 total channel outputs     8 channels   20 amp maximum  22 channels   10 amp maximum    12 hardwired switch inputs    Data Output   Volts   Amps   State    Response   3 0 millisecond    Programming   USB Interface    Dimensions   6     L  X 5 5     W  X 1 5     H    25 2 cm X 13 9 cm X 3 8 cm     Includes   Racepak SmartWire Module  Connector Kit        SmartWire  Switch Panel    SmartWire Module Kit                                500 KT SW30   SmartWire Switch Panel                              500 SW PNL8 
29.  between  9 55 1 and 20 1  while methanol is shown from 4 22 1 to 8 7 1  Please specify the type of fuel you will be using when ordering  Each sensor    includes one weldment and plug     AIR FUEL CONTROLLERS  SENSORS MUST BE ORDERED SEPARATELY     2 Channel Controller      00000nn ene 220 VM AF2  For use with 2 A F sensors    4 Channel Controller  Cylinders 1  3  5  7         220 VM AF4 1357  For use on 1  3  5  7 cylinder bank of V8  i e  GM 8 Mopar    4 Channel Controller  Cylinders 2  4  6  8         220 VM AF4 2468  For use on 2  4  6  8 cylinder bank of V8  i e  GM 8 Mopar    4 Channel Controller  Cylinders 1  2  3 4         220 VM AFS 1234  For use on 1  2  3  4 cylinder bank of V8  i e  Ford    4 Channel Controller  Cylinders 5  6  7  8         220 VM AF4 5678  For use on 5  6  7  8 cylinder bank of V8  i e  Ford    Air Fuel Sensor Only ERR Ra bah bb bb o 810 SN AFAMP   Air Fuel Weldment  amp  Plug                         810 TX AFWLDP  Weldments are included with purchase of controller    Air Fuel Harness    A    Side                  rr nnn 280 CA LSUA   Air Fuel Harness    B    Side                   n nn 280 CA LSUB    Single Air Fuel Controller with Sensor   Single channel air fuel sensor package  Includes controller   1  Bosch LSU air fuel  sensor  weld bung  wiring harness  instructions  Includes 0 5V reference output for  external devices  For use with Racepak V Net data loggers  AFIPacKdj6 iz  RE EGE REA EECHERONGcARRC RR E RR SOR RR AA 220 VM AF1    Relay Co
30.  connection to the data logger via the same V Net cable utilized by the  external sensors  the UDX display is capable of    sharing    sensor data with the  data logger  thus providing the ability to display or trigger warnings based on  any internal or external sensor in use by the data logger     UDX Display             10 aaa aaa aaa anan  250 KT UDX    LUTEA LET       The IQ3 Display Dash can be utilized with any of Racepak   s V Net data loggers   providing a compact  fully programmable LCD digital dash for use in a variety  of motorsports    A single V Net cable is routed to the rear of the dash  providing power and  access to all sensor information transmitted to the data logger  Up to 24 different  sensor inputs may be displayed on a total offour programmable pages  The blue  backlight provides excellent viewing for both daylight and nighttime usage  while  the low luster display screen provides excellent protection against scratches    Progressive shift lights  eight warning lights and all inputs are easily  programmable through the Datalinkll software supplied with each data logger     IQ3 Display Dash                   rrrre 250 DS IQ3  I3 External Programming Buttons       INSTRUMENTATION    Specifications    Display up to 21 sensor inputs via 4 pages   Adjustable backlighting   User defined warning lights  Minimum Maximum recall    Includes   UDX Display Dash    Display Dash Provides   Any 21 sensor inputs   Shift Lights   Warning Lights    Dimensions    4   H  X
31.  from 0 400  F    The IR Temperature sensor has a 4 1 ratio focal point  That means that when the item  being monitored is four inches away from the sensor  the focal point will be one inch in  diameter  If the sensor is twelve inches away  the focal point will be three inches in diameter     IR Sensor and V Net Module                rnnns 220 VP IR T 200  IR V Net Module only               eee 230 VM IR  IR Temp Sensor only                r rr rrrrmrr 810 SN IRT 200    Wide Open Throttle Sensors    Wide open throttle event switches are used on Holley  carburetors to verify when the  carburetor is at full throttle and the throttle blades are wide open  Two styles of mounting  brackets are available  Both bolt directly to the side of the carburetor main body  Monitoring  WOT requires an available V Net channel     Switch Only  WOT               c rrr rmn nb 800 MB WOT SW  Cable Only  Pigtail For WOT Switch                280 CA HARNWOT  Switch  amp  Pigtail Only                   nnn 800 MB WOT SWC  Bracket Only  WOT  Holley 750 Style                 800 MB WOT 750  Bracket Only  WOT  Dominator Style               800 MB WOT DOM  Bracket with Switch  amp  Pigtail Cable    Dominator Style Carb                     nnn 800 MB WOT SCB  ADAPTER MODULE    V Net Module            c er rrrrrnh rmm mmn 220 VP WOTEVENT       0   300  F Fluid  Temperature Sensor       Infrared Temperature  Sensor             Shock Travel Sensors   Monitoring suspension travel aids greatly in gaining an u
32.  machined  black anodized mounting bracket  Pre drilled for corresponding    IQ3 mounting stud and pattern   IQ3 Mount Bracket                              e  800 MB IQ3    Typical Uses  Base Logger Dash Provides Viewing of     Road Racing GPS Lap Time and Lap Number   Circle Track GPS Speed   Marine Battery Voltage   Pulling Accel G Lateral G Vertical G  Engine RPM  with appropriate tach signal   shift Lights  Warning Lights    Gear Indicator  with appropriate tach signal     Data logging of included internal sensors and optional external sensors    28 total programmable inputs on four display pages       FEATURES    Channels    37 total   V Net  32 digital analog  Internal  5    Sample Rates   V Net  up to 100 per second    Memory    Up to 16GB microSD Memory Card   Recording time depends on number of channels  monitored and sample rates    Dimensions   7 25     L  X 4 000   W  X 1 125   deep    18 41cm X 10 16cm X 5 39cm     Weight   1 Ib   4539     Specifications    32 external sensor input with optional high speed  logging modules    Internal GPS board   Display up to 28 inputs via 4 pages   microSD Memory Card   Blue backlight   3 Axis G meter  Accel  lateral  vertical    Gear Indicator   Eight user defined alarms with on screen warning  text and lights   User defined 5 character sensor input names  User defined shift lights   GPS Track Mapping   GPS Speed and Lap Time   Power Ground Engine RPM  Remote  Programming harness   Shielded  low luster display for sunlight vie
33.  sensor inputs may be displayed on a total of four programmable pages  The blue  backlight provides excellent viewing for both daylight and nighttime usage  while  the low luster display screen provides excellent protection against scratches    Progressive shift lights  eight warning lights and all inputs are easily  programmable through the Datalinkll software supplied with each data logger    In addition  the IQ3 dash can be utilized as a standalone display dash   independent of a Racepak V Net data logger  through the use of optional sensors  off of the V Net port  located on the rear of the dash     IQ3 Display Dash eh eee 250 DS IQ3    I3 External Programming Buttons        INSTRUMENTATION    FEATURES        ES  m  a    Specifications    Display up to 21 sensor inputs via 4 pages   Adjustable backlighting   User defined warning lights  Minimum Maximum recall    Includes   UDX Display Dash    Display Dash Provides   Any 21 sensor inputs   Shift Light Output   Warning Lights    Dimensions    4   H  X 10 2     W  X  75    deep        Requires 2  rear clearance    10 16cm X 25 90cm X 1 90cm     Weight   21 ozs    58 kg     UDX Display          Specifications    Display up to 28 inputs via 4 pages   Blue backlight   Gear Indicator   Eight user defined alarms with on screen warning  text and lights   User defined 5 character sensor input names  User defined shift light output   shielded  low luster display for sunlight viewing  Metric and English capable    Dimensions   7 25  
34.  sensors  Sometimes referred to as a Data Logger or    Computer        Digital  This term refers to a sensor or signal having only two values  For example  a wide open throttle switch  is either on or off  Digital channels  by counting or timing the transitions from off to on  can also be used to  measure RPM  For instance by monitoring the number of pulses from the ignition tach output  a data recorder  can determine and monitor the engine RPM     Download  The common term for the process of transferring the information stored in the data recorder to  a device  such as a data cartridge  for the purpose of loading it into another piece of hardware  such as a  desktop computer for analysis  Also see Upload     EGT  Abbreviation for Exhaust Gas Temperature  EGT   s are commonly used as an indicator of whether a  cylinder is running rich  cool  or lean  hot   Thermocouple probes in the exhaust headers are used to monitor  the EGT s     K or KB  Abbreviation for Kilobyte  Each sample of recorded data represents approximately two bytes  A  kilobyte is 1024 bytes  It takes about 1 KB to display one page of double spaced text on your computer screen   See MB or megabyte     MB  Abbreviation for Megabyte  A megabyte is one million bytes  technically correct 1 048 576   or one  thousand  1 024  kilobytes  Most large novels could fit into a MB with room to spare  Your auto insurance  policy disclaimer would not     Memory  The capacity of a data recorder or PC to store information  usu
35.  user manual       Sportsman Mounting Bracket    Includes logger mounting plate  black anodized billet aluminum clamp bracket    1 250    dia LUDE ciare 610 MB 125  1 500  dlatuDe ee NR TEE ENER REESEN a 610 MB 150  1 525  dia  UDG   ios AA NAN AN dewey EE RE 610 MB 1625  1 750  Gla UDE ss iii 610 MB 175    www RACEPAK com           m    wi  b     Uo  DATA RECORDER        Racepak  3     MODE  DISP         The LDX Logger Dash combines a digital display dash with an internal  data recorder  creating a compact  lightweight  all in one data acquisition  system  The LDX Logger Dash utilizes the benefits of Racepak   s single cable  V Net technology by sharing the data from all sensors with the data logger   In addition to the wiring harness  which imports the signals from the engine  RPM  driveshaft RPM  water temperature  oil pressure and battery voltage   up to 32 optional sensors may be attached via the single V Net cable  This  yields a total recording capacity of 37 sensor inputs    The LDX Logger Dash can record and upload data to a PC via a supplied  serial cable  while at the same time displaying the input from up to 21 of  those sensors on the display screen  With a simple push of a button  users  can view the displayed sensor data by scrolling through four screens of  information  Each page contains five user programmable sensor inputs   plus the engine RPM bar graph    Selecting what sensor data will be viewed is accomplished through the  Datalinkll software  Also inclu
36.  user programmable using the Datalinkll software  Shift light module does not include  the shift light  See Shift Light on page 36  This module will also show you when the shift  light was triggered to come on    Shift Light Module  Light not included           230 VM SHIFTLT    Tach Converter   The output signal that is used to trigger magnetos is different than a conventional  electronic ignition  This compact device converts the Pro Mag s coil signal into a 12  volt square wave signal so common tachometers designed for electronic ignitions can  be used with the Pro Mag     MSD Pro Mag Tach Converter                 810 SN MAG CONV  MSD Magneto Pickup Adapter    MSD 12 or 20 amp mag  800 CA MAGADPT   Cable provides easy connection for RPM sensor between magneto and coil     Ignition Timing Kit   By equipping the V500 data recorder with this kit it can track the overall timing  or  if you are using a battery ignition system that provides adjustable individual cylinder  timing  you can monitor the timing on each cylinder as well  These kits provide the  components to compare the crankshaft   s position to the firing pulse s  of the ignition   Magneto equipped engines  or battery ignition engines without individual cylinder timing  Capabilities  would use the overall timing kit   Ignition Timing Kit  Overall  V500 Only          800 KT TIMINGOV  Ignition Timing Kit  Individual  V500 Only          800 KT  TIMING    V300SD customers can monitor overall ignition timing utilizing R
37. 0 TC S4 SET1   2 each  9   13   18     23     Big block Heads D 800 TC S4 SET2  B    sets  1 each  18     23     28     32      800 TC S4 SET3   1 each  13     18     21     28        Set of 8   two of each length noted        Small block Heads D   S  sets       Special Purpose    Thermocouples  These Type K thermocouple assemblies  Nickel  Weldment  Nut  amp  Ferrule Assembly   800 TX WASM3   800 TX WASM4      l s Weldment Only  Single 800 TX WELD4  SIMILYA KE Pet a BRI aie pecially ii TE Stainless 800 TX WELD4SS    crea   designed for ine applications listed below  Each Weldment Only  Set of 4 fT 800 TX WELD404  must be used with the appropriate thermocouple Weldment Only  Set of 8       800 TX WELD408  pM    amplifier module  All probes are 12  in length and Ferrule Only 800 TX F4  are terminated with a male two pin mini connector  Nut Only     800 TX WNUTA  The liquid and manifold assemblies are provided  Cap Only        800 TX CAP4    with a 1 8  male NPT compression style fitting  Nut  amp  Ferrule Only      800 TX NF4    Cylinder Head Temperature Thermocouple Assembly    800 TC MT ASM  Ring type sensor is used to monitor temperature of the metal  not the coolant        Fluid Temperature Thermocouple Assembly            800 TC FT ASM  Used where the probe can be immersed in liquid  such as in a dry sump tank   Manifold Temperature Thermocouple Assembly         800 TC MT ASM    Open end probe reacts quickly to changing temperatures in manifold plenum     Thermocouple Ass
38. 00 162  V300 V300SD Recorder Mounting Brackets   for 1 750  O D  tubing                        800 MB V300 175    Recorder Mounting Brackets    www RACEPAK com       DATA RECORDERS          WE  FEATURES  DATA RECORDER    DVd    Channels    75 total   V Net  56   Analog  8 hard wired  Digital  8 hard wired  Internal  3    Sample Rates    V Net  up to 100 per second   Analog  up to 1000 per second   Digital  RPM and switch contacts up to 100 per  second   Digital  Timing intervals within 1 1000 of a  second    Memory    4 MB   Recording time depends on number of channels  monitored and sample rates    Internal Sensors        Battery Voltage  Longitudinal g meter  acceleration and  deceleration   If you need to monitor many channels of information while using fast Lateral g meter  side to side motion   sampling rates for extended recording periods  the V500 is for you  The  V500 handles more channels of information than the V300SD data recorder  Dimensions     5 350   L  X 5 550     W  X 1 215     H     supporting up to 75 total channels of information  With that comes high  13 598cm X 14 09cm X 3 08cm     sampling speed rates  up to 1000 sec   and an internal recording capacity  of 4 MB of memory  Information can be displayed in real time on a PC Weight   monitor  uploaded to the PC for analysis using the Racepak Datalink Data 17 ounces  48 kg   Analysis software  or displayed on the optional Intelli Gauges  UDX dash or  IQ3 display dash  The V500 can be equipped to monitor ove
39. 1G 170BB  PRESSURE  FUEL 250 1G 165BB  PRESSURE  FUEL NA   PRESSURE  FUEL NA   PRESSURE  BRAKE 250 1G 180BB  PRESSURE  NITROUS 250 1G 175BB  PRESSURE  Generic 250 1G 190BB  PRESSURE  Generic 250 1G 193BB  PRESSURE  Generic A   PRESSURE  Generic 250 1G 197BB    BOOST   VACUUM 30 psi 0 30 In  hg 250 1G 215BB    TEMPERATURE  EXHAUST GAS  2 600   1 600  F 250 IG 145BB    TEMPERATURE  EXHAUST GAS 0 1000 C    BOOST A   VACUUM 250 IG 210BB  AIR FUEL RATIO  FLOW  FUEL LEVEL  VOLTS 250 1G 200BB  VOLTS  with internal sensor  250 1G 204BB  VOLTS NA    N    0  TEMPERATURE  EXHAUST GAS 600   1 600  F 250 IG 140BB  F    N  N  NA  NA  NA       After the first gauge each subsequent gauge is connected with a gauge to gauge jumper cable     The first Intelli Gauge connects to the  V Net cable using a Gauge Tee Cable         8     280CA RGG 00  Gauge to Gauge   umper C ables 280 CA RGG 016    Used to connect each gauge in series after the first gauge   Each endofthe cable has the small round connector that plugs 280 CA RGG 024  directly into the back of the Intelli Gauges  280 CA RGG 048    280 CA RGG 288    8       280 CA RGG T008      Gauge Tee Cables 280 CA RGG T016  Connects first gauge to V Net cable or another V Net module   280 CA RGG T024    www RACEPAK com          Racepak s Vehicle Network  V Net  is a    smart data    transfer network providing the ability to transmit multiple signals from each  sensor over a single cable  This technology creates a system in which the individual comp
40. 20 VP PT TP300  Turbo Back Pressure  1  0 75 psi               220 VP PT EP175  Turbo Back Pressure  2  0 75 psi               220 VP PT EP275  Turbocharger Outlet  1  0 75 psi                 220 VP PT TB10  Wheelie Bar  Left  0 3000 psi                  220 VP PT WBL3K  Wheelie Bar  Right  0 3000 psi                 220 VP PT WBR3K  VACUUM  Manifold  30 psi 0 30 In  hg                        220 VP PT BVAC  Pan  Crankcase   0 30 In  hg                e   220 VP PT PVAC  TEMPERATURE    Note  pigtail cable lengths are shown in parenthesis     Cylinder Head  Left  0 600  F   36                220 VP TC HEADL  Cylinder Head  Right  0 600  F   367              220 VP TC HEADR  Engine Oil  0 300  F   48      nnn eee 220 VP TR OIL  Intake Manifold  Open Tip  0 600  F   36             220 VP TC MANIF  Intercooler Inlet  0 300  F   727            rrr 220 VP TR ICTI  Rear End Oil  0 300  F   72               err rrrrmr 220 VP TR RET  Transmission Oil  0 300  F   72            bb bo 220 VP TR TRANS  Water  0 300  F   727        err rrr m m m rn imIRImRR 220 VP TR WATER    Fluid Temp 0   300  F          TEMPERATURE  continued    Exhaust Gas Temperatures Cylinder Bank Sets   EGT  Junction Box 8 4 Probes  1357  Small Block     220 VP TC 1357S  EGT  Junction Box  amp  4 Probes  2468  Small Block    220 VP TC 2468S  EGT  Junction Box  amp  4 Probes  1357  Big Block         220 VP TC 1357B  EGT  Junction Box  amp  4 Probes  2468  Big Block    220 VP TC 2468B    EGT  Junction Box  amp  4 Pro
41. 230 VM EFIHAL  Megasauirt   230 VM EFIMSI  Omex 230 VM EFIOMEX    Vipec 230 VM EFIVIPEC  WOLF V500 230 VM EFIWOLF          Shift Light Event Module    The Shift Light Module allows you to use any LED style light  300 milliamp maximum   as a fully programmable  stand alone shift light  By accessing the engine RPM off of  the V Net you can program up to six separate shift alarm signals  Each shift point is  user programmable using the Datalinkll software  Shift light module does not include  the shift light  See Shift Light on page 36  This module will also show you when the shift  light was triggered to come on    Shift Light Module  Light not included           230 VM SHIFTLT    GMR Sensor    The GMR  Giant Magneto Resistive  sensor acquires a tach signal inductively from a  current carrying wire  and provides an RPM sign of 3096 duration when the ignition coil  fires  It can be used on the following types of ignition coil systems  Capacitive Discharge  Ignition  Inductive Coil per Cylinder Ignition  Distributorless Coil Pack Ignition  or Diesel  Injector  Complete instructions for installation on each type of ignition system are provided  with the sensor  No cutting or splicing required    GMR Inductive RPM Pickup  Black G2X              680 SN GMR  Red G2X              680 SN RGMR          GMR Inductive  Pickup             eh      SN  L    A     lt  lt      A       Air Fuel Sensors   Racepak has created a selection of A F controllers and sensors created specifically for tun
42. 40 IM TRAV48RR  Shock Travel  Right Rear  72    Pigtail           240 IM TRAV72RR  Shock Travel  Left Rear  48    Pigtail            240 IM TRAV48LR  Shock Travel  Left Rear  84    Pigtail  Std         240 IM TRAV84LR       Digital Interface Modules without Sensor    ET siii 240 IM TACH Shock Travel  Zero Crossing Sensor Input                 leeren 240 IM ZX Interface Module  Contact Closure Sensor Input                   rrr 240 IM CC   Contact Closure Sensor  12v Output               240 IM CC 12V    Door Car Drag Shock Kit Front    Includes two 0 4    travel linear sensors  two IM modules   108  IM cable and installation instructions     Front Kit 280 KT DSHKTRVF       Door Car Drag Shock Kit Rear      o Ta             Includes two 0 8    travel linear sensors  two IM modules  6   4 bia  IM cable and installation instructions     Rear Kit 280 KT DSHKTRVR Front Kit Rear Kit             V Net modules and Interface modules  although similar  in construction and appearance  are very different in the  functions they perform  It is important that components  designed for one system not be interchanged with  the other  V Net cables use a 5 pin connector  while  Interface cables use a 7 pin connector  So that cables  can be identified at a glance Racepak has color coded  the connectors on the end of the cables  V Net cable  connectors are blue  just like the modules to which they  attach  while Interface cable connectors and modules  are black    The cables listed may be used to 
43. 500  dia tube  aaa AA a 610 MB 150  G2X 1 625  dia tube  4d eR ERREUR REA Rn 610 MB 1625  G2X 1 750 dlatube 4i    ssaa titani 610 MB 175    UDX Billet Bezel    Direct replacement for factory UDX bezel     Polished Aluminum Bezel                      250 DS BZLUDXB     Q3 Protective Cover    Vacuum formed  crystal clear protective cover for IQ3 dash    Cover with flange                           250 DS IQ3 CVRWF  Cover without flange                           250 DS IQ3 CVR  IQ3 Mount    CNC machined  black anodized mounting bracket  Pre drilled for corresponding  IQ3 mounting stud and pattern     IQ3 Mount Bracket                    rer rr nnn 800 MB IQ3    Mounting Brackets  V300 V300SD Recorder Mounting Brackets     for 1 250    O D  tubing             ssa 800 MB V300 125    V300 V300SD Recorder Mounting Brackets     for 1 500    O D  tubing                      800 MB V300 150    V300 V300SD Recorder Mounting Brackets     for 1 625  O D  tubing                        800 MB V300 162    V300 V300SD Recorder Mounting Brackets     for 1 750  O D  tubing                         800 MB V300 175       Recorder Mounting Brackets             Mounting Brackets  continued   G2X Pro V500 Recorder Mounting Brackets     for 1 250    O D  tubing            sso 800 MB V500 125    G2X Pro V500 Recorder Mounting Brackets     for 1 500    O D  tubing                          800 MB V500 150    G2X Pro V500 Recorder Mounting Brackets     for 1 625    O D  tubing             sso 800 MB V500 1
44. 62    G2X Pro V500 Recorder Mounting Brackets     for 1 750    O D  tubing                         800 MB V500 175    I3 Mounting Panels    Trim to fit  vacuum formed plastic mounting panel     Faux Carbon                    ecrrnnh nnn 800 MB IQ3 PCF  Black    cece eee RII RRRrr 800 MB IQ3 PBLK  SIIUBE saa PUGAD ea 800 MB IQ3 PAL    GeX Mounting Panels    Trim to fit  vacuum formed plastic mounting panels     Faux Carbon                  scrr Rh hm RR 600 MB G2XDPCF  CET ART TRITT Naa PADA KATAGA 600 MB G2X DBLK  Silver si    ici 600 MB G2X DPAL    UDX Mounting Panels    Trim to fit  vacuum formed plastic mounting panel     Faux Carbon      eu 800 MB UDX PCF  Black TEE 800 MB UDX PBLK  Silver geet EE AA ee ee we ae 800 MB UDX PAL       Recorder Mounting Brackets          k    e   LAL  Dorao   e EC  emm  Mos it nos cL    Pio HUGHES            Serial Communication Cables   The serial cables that are used to communicate or download data from the V50 V300 V300SD V500 recorders are  unlike those found in computer stores  If you need a replacement for your serial cable choose the proper cable from  the selection below     Serial Communication Cable  V50 Playback Download Module  25                       280 CA SR V50  Serial Communication Cable  V300  25                 ee 280_CA SR V300  Serial Communication Cable  Stereo Jack style  V300SD  Sportsman  G2X red  6           280 CA ST140SR  Serial Cable  V500  V600  35       1  ee 280 CA SR V500  Serial Cable  G2X Pro  35    NN ege
45. B  250 1G 200WB  250 1G 204WB    250 1G 221WB    PIT    250 IG 110BB  250 IG 120BB  250 IG 130BB  250 IG 140BB  250 IG 145BB     gt     250 IG 150BB  250 1G 135BB  250 IG 160BB     gt     250 IG 170BB  250 1G 165BB     gt     250 1G 180BB  250 1G 175BB  250 1G 190BB  250 IG 193BB     gt     250 IG 197BB  250 IG 215BB     gt     250 IG 210BB    PIT  N     gt   N    ik  a  M ELM     gt     250 1G 200BB  250 1G 204BB       After the first gauge each subsequent gauge is connected with a gauge to gauge jumper cable         The first Intelli Gauge connects to the  V Net cable using a Gauge Tee Cable      8     280CA RGG 008  Gauge to Gauge   umper Cables 280 CA RGG 016  Used to connect each gauge in series after the first gauge   Each end of the cable has the small round connector that plugs 280 CA RGG 024  directly into the back of the Intelli Gauges  A   0 280 CA RGG 048  250 CA RG6 208    8   280 CA RGG 7008      Gauge Tee Cables 280 CA RGG T016  Connects first gauge to V Net cable or another V Net module           Racepak s Vehicle Network  V Net  is a    smart data    transfer network providing the ability to transmit multiple signals from each  sensor over a single cable  This technology creates a system in which the individual components interact with each other  making a  simpler  more compact system which can be expanded with ease    The key to accomplishing this is in the modular connectors that attach each of the devices to the main V Net cable  Each module  is essential
46. CA IM 060  72    280 CA VM 072 280 CA IM 072  84    280 CA VM 084 280 CA IM 084  96    280 CA VM 096 280 CA IM 096  108    280 CA VM 108 280 CA IM 108  E R   280 CA VM 120 280 CA IM 120  144    280 CA VM 144 280 CA IM 144  168    280 CA VM 168 280 CA IM 168  280 CA VM 192 280 CA IM 192   a 280 CA VM 216 280 CA IM 216       280 CA VM T009  280 CA VM T018  280 CA VM T036        Tee Cable  9     Tee Cable  18     Tee Cable  36           280 CA IM T 009       Terminator Cap  Male 280 CA VM TCAPM       280 CA VM TCAPF       Terminator Cap  Female          Dust Cap  Male    280 CA IM DCAPM           Dust Cap  Female          Bulkhead Connector 280 CA VM BHEAD    280 CA IM DCAPF  280 CA IM BHEAD                umm 7t db aa   ri    Ti BF  a   E mur  gt  CANG LING V   sn    oe       In the section that follows  you will find a selection of sensors that are applicable to every type of recording device  These sensors  will provide you with the means of expanding your system to record or display almost any function you wish  It is important to use  the appropriate type of signal conditioning module and cable for each application when applying any of these sensors to the various  recorder systems        Pressure Transducers   The small size and ruggedness of these    PT type    pressure transducers make them ideal for the measurement of pressure directly  at the source  The transducer requires 5 volt DC power and provides a  5 to 4 5 volt output signal  Each transducer mounts using a  1 8
47. DC power and provides a  5 to 4 5 volt output signal  Each transducer mounts using a  1 8    NPT male pipe fitting           O45 Sli AA AA r   810 PT 0015GVT   0 15 PSE AA 810 PT 0075GVT   0 150 DS siria 810 PT 0150GVT   0 300 pel    810 PT 0300GVT   0 500 KC 810 PT 0500GVT   0 1500 psi       22222                       810 PT 1500HP   0 3000 psi       22 cece cece eee eeeeeeeeeeeeees 810 PT 3000HP  VACUUM PRESSURE SENSOR   30 In  hg 0 30 psi  Vacuum Boost                     810 PT VB PSI Sensors  ADAPTER MODULES    The pressure sensors listed on page 19 can be adapted to the V Net cable or analog port of the recorders by using the appropriate  signal condition module     V Net Module  see page 45                   eese 230 VM PT 5V  For connection to the V Net cable on V series recorders   Interface Module  see page 23                    240 IM PT 5V    For connection to the Analog port on V series recorders     Fuel Flow Meter Sensors    Monitoring pressure to evaluate your fuel system will only give you half of the picture  To know the exact status of how it is affecting  your engine you must also know the fuel volume  These general purpose turbine type flow meters require an available digital channel    Gasoline and Nitro methane flow meters are constructed of aluminum  Methanol fuel requires the use of a stainless steel flow meter  A  tee fitting must be used so all fuel can be routed through the flow meter before it is divided between the hat nozzles and the port nozzl
48. ES  V Net Module   isa AA ERR RN Rer e 230 VM TR 300  Used to connect the 810 TR 300 sensor to the V Net cable   Interface Module      000nnce een eee 240 IM FT350    Used to connect the 810 TR 300 sensor to the Analog port     Infrared Temperature Sensors   These infrared sensors are used to monitor temperatures where contact cannot be made  with the item being monitored  In racing  they are commonly used to monitor temperatures  across the face of a tire  but they can be used for any non contact measurement  The  sensor will measure temperatures from 0 400  F    The IR Temperature sensor has a 4 1 ratio focal point  That means that when the item  being monitored is four inches away from the sensor  the focal point will be one inch in  diameter  If the sensor is twelve inches away  the focal point will be three inches in diameter        IR Sensor and V Net Module       000000n nen 220 VP IR T 200  IR V Net Module only               ee 230 VM IR Infrared Temperature  IR Temp Sensor only aaa  810 SN IR T 200 Sensor    STRING POTENTIOMETER    This sensor is typically used for linear measurements  such as throttle position  when the mounting  angle is not critical  The sensor is calibrated to the travel of the throttle  i e  0  when closed and 100   at WOT   By using a string potentiometer  the possibility of interference with the throttle operation is  eliminated  Operating range 0 4 750           String Potentiometer Sensor                   800 LN STRINGP e  ADAPTER MODULES  
49. G HARNESS          BLUE  START RECORDING BUTTON   RED  12V POWER SWITCH   BLACK  ENGINE RPM    a a  CLUTCH RPM  IF USED     Y  DRIVESHAFT RPM               Racepak s digital display di     EUR BENE BERE piii      n  dashes  Some models of Terminator V Net Cables   the dash will rely solely upon ge   the data recorder s sensors   to provide the information   they display  while others   are stand alone requiring S i   no data recorder  When Pressure Pressure  you add Datalink Il  the best vachorider Gipi ie I Bees  Windows   based software in Gauge  amp  Module Gauge  amp  Module   the business  you will see why i EGT   Racepak continues to be the SM    most popular and widely used  data acquisition system in the  industry     V Net Modules    In order for a function to be monitored on the V Net  the signal from that function must pass through two components  a sensor and  a module  The sensor is the unit that actually measures the input from the function  i e  pressure  temperature  etc    while the module  converts the signal so it can be transmitted over the V Net  To make it easy for you to select the proper components  Racepak offers  a variety of manners  as shown below  In the module sensor section that follows  you will find a complete listing of these components  divided into the following categories        Analog V Net Modules     with sensor  pre programmed   without sensor  pre programmed   with sensor  not pre programmed        Digital V Net Modules     with senso
50. II  or equivalent CPU    10 GB of available hard drive space   200 RPM recommended   l  128 MB of RAM  AA a mem SERE  Video screen resolution of 1024 x 768 pixel  1280 x 1024 is recommended    Video card with 64 MB RAM    Windows    98SE  Me  2000  XP or Vista operating system  XP is recommended                  Racepak s Datalinkll family of software programs are the  finest available to motorsports  Datalinkll is easy to learn  user   friendly in terms of working within the programs  and above all   capable of quickly and clearly providing the information you  need to achieve success    An enormous amount of thought and work has gone into  designing this software  Writing software programs that are  useful to racers  whether they are a drag  oval track  or road  racer  as well as those gathering data not associated with a  vehicle  require years of development  Through this process  we arrived at three levels of Datalinkll        DATALINKII LITE  is the base version software used with all  Racepak V series data recorders  It provides the ability to upload  recorded information to your PC allowing you to view the data   in both a numeric and graphic format  Each monitored function will have a channel button displaying the numeric value of that channel   at the cursor s location   while also permitting you the option of displaying the channel s data on the scaled graph  Special channels  are included to provide clutch and transmission slip curves when the appropriate sensors 
51. N 12V    Adapts external G meter to V Net cable        Wheelie Bar  Load Cell          Ride Height Sensor    ex    G force Sensor          Pro Analog Transducer Box II   This is the next generation Pro Analog Transducer Box which is a smaller and lighter version  than the previous analog transducer box  Just like the past analog transducer box  this is an  additional method of connecting analog sensors into the V Net recorders  Each Pro Analog  Box will house up to four of the Plug In style transducer modules  The box is then connected  to a single V Net cable  Plug In style transducers and adapter modules must be purchased  separately   Pro Analog Transducer Box Il       0000n nee 230 VM 4TD       FRAME RAIL BRACKET  Adapts Pro Analog Box Il to round tube              800 MB TB2    Transducer Modules  Plug In Style      When using the Pro Analog Transducer Box these plug in style transducers and signal conditioning  modules are used to convert the input from various analog functions into signals that can be  recognized by the recorder  Where required  a special cable is needed for connecting the sensor  to the module   Pressure Transducer  PSI              810 MD PT2  specify psi    Available in ratings of  O to 15 60 100 150 300 750 1500  Used to measure pressure from  parameters such as fuel  oil  boost  nitrous  Route your pressure line directly to the transducer   Transducer has 1 8    NPT female thread     Vacuum Transducer  0 30 In  hg                 810 MD PT2 VAC  T
52. R eee 810 SN AFAMP  Air Fuel Weldment  amp  Plug                       810 TX AFWLDP  Weldments are included with purchase of controller  2 Channel Air Fuel  Air Fuel Harness    A    Side              creen 280 CA LSUA Controller  Air Fuel Harness    B    Side                nnno 280 CA LSUB    Air Fuel    Single channel air fuel sensor package  Includes controller   1  Bosch LSU air fuel  sensor  weld bung  wiring harness  instructions  Includes 0 5V reference output for  external devices  For use with Racepak V Net data loggers  Hahn EE ea 220 VM AF1    Relay Control Module   A Relay Control Module is the device which permits the V Net system to perform  a host of automated tasks  It allows any information transmitted over the V Net to be  used to activate external high power devices such as a switch  solenoid  water pump   fan  or lights  Each module has two programmable output relays    Each relay can have up to two separate  analog and or digital  control signals that  must be met before the relay is engaged  For example  one relay can be programmed  to turn on a water pump only when a  Pump  switch is on and the water temperature  is above the programmed value  while the other relay can be used to activate an  ignition kill switch only if the engine RPM is above a programmed value and the oil  pressure is lower than a predetermined pressure  Relays are included    Relay Control Module                           230 VM RELAY Relay Control  Module                 Steering 
53. The V Net compatibility insures a seamless integration with existing  Racepak data logger or displayed equipped vehicles  while also providing a  future upgrade path for additional inputs  control modules and instrumentation   when utilized as a standalone power control module    Each Racepak SmartWire Kit includes the module and connector kit           FEATURES    Capacity   125 total amps    Channels    30 total channel outputs     8 channels   20 amp maximum  22 channels   10 amp maximum    12 hardwired switch inputs    Data Output   Volts   Amps   State    Response   3 0 millisecond    Programming   USB Interface    Dimensions   6     L  X 5 5     W  X 1 5     H    25 2 cm X 13 9 cm X 3 8 cm     Includes   Racepak SmartWire Module  Connector Kit        SmartWire  Switch Panel    SmartWire Module Kit                                500 KT SW30   SmartWire Switch Panel                              500 SW PNL8   SmartWire Switch Module                            500 SW 5MI6   Switch Panel Mount Brackets                         500 MB SPxxxx  Available sizes are  1 50   1 625  and 1 75    SmartWire to Switch Panel Cable                      580 CA BN5P xxx  Variety of sizes offered    SmartWire to V Net Cable                   e rn nn n nm 280 CA BN5P xxx  Available sizes are  9   18  and 36      www RACEPAK com          Go A    Includes logger mounting plate  black anodized billet aluminum clamp bracket    G2X 1 250 dia 1UDE  anakan ARKA ARNAN RAR RR ARR RC 610 MB 125  G2X 1 
54. Throttle Brake Kit  GPS based systems like the G2X and G2X Pro  are commonly used for the purpose of assessing  a vehicle s handling characteristics in response  to the driver s input  Popular functions that are  monitored in this evaluation are the driver s  steering input  throttle position  and front and  rear brake pressures  Racepak has made it easy  to add this commonly used selection of sensors  to either the G2X or G2X Pro by packaging all  sensors and cables in a kit with a single part  number   Steering Throttle Brake Kit  620 KT STBB    Steering Throttle Brake Kit    Shock Travel Kit  G2X Pro only     Monitoring the extension and compression travel of the shock absorbers is one of  the prime methods of evaluating the suspension movement and chassis setup  This  Shock Travel Kit provides the necessary components to provide that information   The kit includes four 0 8 inch travel sensors and cables  Also included are four Turck  connectors which simplify the job of custom tailoring the length of the cables for your  application  as well as two Turck bulkhead connectors  Center to center distances  on the shock travel sensor mounting points are 12 6 inches collapsed and 20 6  inches extended    Shock Travel Kit RER eee 620 KT 4SHOCK       Shock Travel Kit i                      Ride Height Kit  G2X Pro only     The Ride Height Kit has been packaged to provide the components used to monitor  the distance between the ground and the sensor at the four corners of the car 
55. UGE SELECTION CHART   Gauge includes connector cable  Sensor and modules available on page 24 30     RPM  TACHOMETER   RPM  TURBINE PERCENTAGE  N1  RPM  TURBINE PERCENTAGE  N2  TEMPERATURE  WATER  Street   TEMPERATURE  WATER  Race   TEMPERATURE  OIL  TEMPERATURE  EXHAUST GAS  TEMPERATURE  EXHAUST GAS  2  TEMPERATURE  EXHAUST GAS  TEMPERATURE  CYLINDER HEAD  TEMPERATURE  TRANSMISSION  PRESSURE  OIL   PRESSURE  OIL   PRESSURE  FUEL   PRESSURE  FUEL   PRESSURE  FUEL   PRESSURE  FUEL   PRESSURE  BRAKE   PRESSURE  NITROUS  PRESSURE  Generic   PRESSURE  Generic   PRESSURE  Generic   PRESSURE  Generic   BOOST   VACUUM   BOOST   VACUUM   AIR FUEL RATIO   FLOW   FUEL LEVEL   VOLTS 8 20  VOLTS  with internal sensor  8 20    VOLTS 20 32    1 000 10 500 RPM  0 120   0 120   100   280  F  60   200  F  140   280  F  600   1 600  F  600   1 600  F  0 1000  C  100   600  F  50   350  F  0 100 psi  0 250 psi  0 15 psi  0 100 psi  0 250 psi  0 500 psi  0 1 500 psi  0 1 600 psi  0 200 psi  0 300 psi  0 500 psi  0 1 000 psi  30 psi 0 30 In  hg  0 60 psi  0 30 In  hg  10 18  3 5 4 5 GPM    250 IG 100BB 250 IG 100WB  250 1G 218 WB  250 IG 219WB  250 IG 110WB  250 IG 120WB  250 IG 130WB  250 IG 140WB  250 IG 145WB   50 1G 220WB  250 1G 150WB  250 1G 135WB  250 1G 160WB   50 IG 162WB  250 IG 170WB  250 IG 165WB   50 IG 167WB   50 1G 226WB  250 1G 180WB  250 1G 175WB  250 1G 190WB  250 1G 193WB   50 1G 223WB  250 IG 197WB  250 1G 215WB   50 IG 217WB  250 IG 210WB  50 IG 224WB  50 IG 222WB  50 1G 225W
56. Use these modules to adapt string potentiometers to V series recorders   V Net Module  see page 20          22222 maaaanan 230 VM TPS  For connection to V Net cable on V series recorders   Interface Module  see page 26                       240 IM TRAV    String    For connection to Analog port of V300 or V500 recorders  Potentiometer           RK               NN BA Se    na    Cc  EE OR  cca i        as    amp          XX LPA        Hide Height Sensor    Infrared sensors are used to monitor the distance to an object  relative to the sensor   when contact cannot be made with the object  This makes them ideal for use in  setting up the suspension by monitoring chassis ride height in relation to the moving  ground plane  Infrared Ride Height sensors and modules are commonly attached to  the V Net cable of any V series recorder  If desired  they can also be attached to the  analog port by using an Interface module rather than a V Net module  These sensors  are designed for use in measuring distances ranging from 3 93 to 15 75 inches  Each  sensor must be used with the appropriate V Net module        Ride Height Sensor Kit  V Net  Left Front        220 VP RIDEHTLF   Ride Height Sensor Kit  V Net  Right Front       220 VP RIDEHTRF   Ride Height Sensor Kit  V Net  Left Rear        220 VP RIDEHTLR   Ride Height Sensor Kit  V Net  Right Rear       220 VP RIDEHTRR Ride Height Sensor  Kit includes V Net module  amp  sensor  Please specify position    Module Only  Ride Height  V Net  L
57. acepak   s V300SD  Timing Kit  Use of this package requires removal of the start logging button  which is  replaced by a crankshaft rpm sensor  Start logging is then initiated by another channel   engine rpm  etc  or by use of a V Net event module which then allows use of the start  logging button     Note the following requirements    Any V300SD not ordered with this option must be returned to Racepak for upgrade      Engine must utilize flying magnet crank trigger wheel     Datalinkll standard software required   e Contact Racepak for complete details   Ignition Timing Kit  Overall  V300SD              200 UG TIMV300S       Shift Light Module       MSD Pro Mag Tach  Adapter    00    Ignition Timing Kit  Overall for V500                   Air Fuel Sensors    Racepak has created a selection of A F controllers and sensors created specifically for tuning race engines  Each of these 2 and 4  channel controllers are designed to be connected to the V Net cable of Racepak V series recorders  When ordering please be aware that  the sensors are calibrated for use on specific ports of the controller and cannot be interchanged from port to port without recalibration   All sensors have a 13    pigtail cable  and the controller has a 37    cable for attachment to the sensor  These lengths cannot be altered     Controllers are ordered by cylinder bank layout     Racepak A F sensors are compatible with either gasoline or methanol fueled engines  Gasoline application will display A F ratios
58. ally expressed in Kilobytes or  Megabytes  The length of available recording time is dependant upon how much memory is available  As the  number of channels and or sampling rates per second increase  the recording time is decreased  Purchase  a data recorder with lots of memory     Sampling Rate  The number of times per second the data recorder logs a sample of the incoming information  on each channel  Many times the number of samples per second can be changed to suit your needs  A  common myth is that faster sampling rates are better  This isn   t always true     Software  The program  usually installed on your PC   s hard drive from a CD and or floppy disc  that provides  the instructions enabling your PC to display and process the information uploaded from your data recorder     Telemetry  The ability to view your monitored functions in real time  V series recorders using the Datalink  Lite or higher version software can display the monitored functions on the computer screen while the vehicle  is running by connecting the onboard recorder to the PC  Recorders equipped with radio transmitters can  display their recorded data in real time without requiring a serial cable connection        pak C Bi  peste om diee SENS       Thermocouple  A probe inserted into the header  usually near the exit of the exhaust port  This is the    sensor     for the exhaust gas temperatures  Thermocouples differ from other temperature probes due to the higher  range of temperatures in which the
59. are installed in your onboard system  A log  book section is included to keep records of each run file    This program also allows data transmitted from all V Net systems and recorders to be displayed on the computer screen in real time   A typical downloaded Datalinkll Lite screen view contains three panels  The top panel contains the run file tabs and channels buttons  for selecting the run file or graph lines you wish to display  Displayed alongside each channel button is that channel s numeric value  coinciding with the location of the graph s vertical cursor  In the center is the graph panel  The graphs are displayed with a timeline  across the bottom and the scale value along the left edge  The bottom panel contains the tabs to access the log pages related to the  file being displayed        DATALINKII STANDARD  adds full math channels support  The math channels provide you with the ability to create your own  channels to display information that is derived from a combination of other collected or known data  For instance  you can create  channels that display total wheel or driveshaft turns  shock rates data in inches per second  If you have a G meter  you can integrate  speed and distance traveled  The combinations are endless     DATALINKII PRO  is a favorite with professional racers or those who spend a lot of time    crunching    the numbers  It adds full access  to the Racer s Logbook  The user can create their own custom log pages which can include calculation sp
60. auges can act as a  watchdog  Each gauge can monitor user programmable  minimum or maximum limits and flash the digital  display  and or a remote light  when either threshold  is exceeded     EASY INSTALLATION  If a function is currently being  monitored on the V Net  simply plug the gauge online  and it shares the signals from that function   s sensor   If not  install a sensor and its module for the function  you wish to monitor  plug both modules onto the V Net  cable  and the installation is complete     ENGINEERED FOR LOOKS AND PERFORMANCE   When you combine the looks and performance of  these gauges you have an unbeatable combination  of elegance and function  Intelli Gauge cases and  connectors are sonic welded to provide maximum  protection against contaminating elements  They weigh  a mere 49 grams  Their smart looks can be attributed  to an easy to read dial face that uses wide spread  increment marks in the prime operating range  a digital  display to complement the needle movement  and a  smooth curved bezel that surrounds your choice of a  white of black dial face     ELIMINATE THE CLUTTER  Using the Intelli Gauge  with one of our data acquisition systems is a great  way to eliminate some of the wiring clutter under the  hood  These gauge derive their signal from the data  acquisition system   s sensors  so there is no duplication  of wiring or sensors as you would have with other  stand alone gauges        INSTRUMENTATION    TREND    D   AN OR if      INTELLI GA
61. bes  1234              220 VP TC 1234  EGT  Junction Box  amp  4 Probes  5678              220 VP TC 5678  EGT  Junction Box  amp  4 Probes  Motorcycle        220 VP TC 1234M  EGT  Junction Box  amp  3 Probes  123                220 VP TC 123  EGT  Junction Box  amp  3 Probes  456                220 VP TC 456  EGT  Junction Box  amp  3 Probes  135                220 VP TC 135  EGT  Junction Box  amp  3 Probes  246                220 VP TC 246    The EGT junction box sets are ordered by the cylinder bank sequence they serve     Exhaust Gas Temperatures Single Cylinder    Single cylinder modules include the thermocouple      EGT  Cylinder  1 nu bb bb ERR RER RRE ERR m mm 220 VP TC EGT1  EGT  Cylinder  2             cerent 220 VP TC EGT2  EGT  Cylinder  3               er rrr nn nnn nmm 220 VP TC EGT3  EGT  Cylinder Z4               RRE nn n nnns 220 VP TC EGT4  EGT  Cylinder  5            nem 220 VP TC EGT5  EGT  Cylinder  6     00 cnn eee 220 VP TC EGT6  EGT  Cylinder  7 bb ne neem 220 VP TC EGT7  EGT  Cylinder  8     0ccn eee 220 VP TC EGT8    Thermocouple Only   187    Diameter  specify 18    or 27    length  Thermocouple Only   250    Diameter  specify 9     18     28    or 36    length    Analog V Net Modules without Sensors   pre programmed    These analog function modules have been programmed for general usage   and have not been assigned to a specific task  Use of these modules on the V Net  cable requires the addition of a sensor and configuration of the module using y
62. bient Light Absolute Humidity  Vapor Pressure  Dew Point  Air Density Ratio    The base AltaCom II kit includes the display console  remote sensor housing  mounting mast  pager  antenna  serial cable   power cable  Merlin Windows software  Additional pager and anemometer can be added as options     AltaCom Il Weather Station Kit                         830 WS ALTAII  Pager  Add a second pager to your weather station      830 WS PAGER  Anemometer Kit  Add wind speed  amp  wind direction to   monitored parameters                kk ERR bb bb bw 830 WS ANEMO    The remote sensor housing is mounted on the PVC  mast under the aluminum solar roof  Also shown is the  optional anemometer which provides wind speed and  wind direction              When making critical tuning decision  monitoring the weather is as important as monitoring the vehicle  The Performaire PC  utilizes your Personal Coputer to gather weather data and predict the performance of your vehicle   The externally mounted sensor housing   wind sensor provides weather data with a single cable connection to the USB    port of your Personal Computer  The aluminum extruded sensor housing is fan controlled to provide accurate readings  even  in direct sunlight       Customers PC calculates weather data    Export weather data to Racepak runfile    Exclusive Oxygen Altitude reading     Trailer Based    PerformAir Weather Station without 02 sensor             830 WS ALTPAPC  PerformAir Weather Station with 02 Sensor           
63. bo Speed V Net Module only                 230 VM TURBO   Turbo Speed Sensor only RR RR enn 800 SS SPEED    Digital V Net Modules without Sensors  Pre Programmed   These pre programmed digital function modules are ready for plug and play installation on the V Net cable  You must add the  appropriate sensor to the module        Zero Crossing Input  see page 26                      230 VM ZX 1  Hall Effect Input  see page 26                   230 VM RPMHE  Contact Closure Input  see page 26                230 VM CC 1  Event Marker Input  12 Volt                 rrre 230 VM EVENT  Event Marker Input  Switch Closure            230 VM EVENTSW  Flow Meter  see page 25                    c  230 VM FLOW  Four Channel Digital Input                rrr 230 VM 4DIGIN  Four Channel Digital Output                230 VM 4DIGOUT Zero Crossing Input    Digital V Net Modules  No Sensor Required  Pre programmed   These modules do not require a sensor  They use the pulse from the component they are monitoring as the signal to the module  Each  has been programmed for the specific use noted and is ready for plug and play installation on the V Net cable     ENGINE RPM     Programmable to read from multiple cylinders applications    Engine RPM Input Module                        220 VP TACH 4    EVENT INPUTS  Transbrake Event  12 volt Triggered      monitors transbrake solenoid                 220 VP TBRAKE  Wide Open Throttle Event  On Off Switched Input    See switch page 28                      
64. can  further divide the track to user defined segments  such as turns and straights  for comparisons  Each report will contain lap or segment  elapsed time  split times  entry speed  exit speed  minimum and maximum speed  acceleration and braking G force  lateral G force   altitude  GPS heading  velocity and more     LOG BOOK  You can keep track of run times  weather data  track information or whatever information you care to note in the comments  section  The higher level programs contain detailed logging of engine  tune up  and conditions data  With Datalinkll Pro you can create  your own customized log book pages and use the math functions to perform those tedious fuel system  clutch management  chassis  set up  or segmented lap time calculations     REAL TIME  By connecting the onboard recorder to your computer with the serial cable you have the ability to view your recorded  functions while they are being monitored  A dynamometer style screen allows you to display all functions on a graph  or up to eight  user defined virtual gauges  Think of how useful this can be during warm ups in the pits     Important information for buyers and sellers    The purchase of a Datalink data analysis program includes a licensing agreement  All Datalink programs are licensed to the  recorder on which they are to be used  They are not licensed to an individual  nor are they transferable between systems  Due to  the customized nature of the software program for the recorder on which it is u
65. ded are output ports to allow connection to  an external shift light and warning light  Shift points can be programmed  using the left and right buttons located at the bottom of the dash  while  reviewing settings on the display  These same buttons are also utilized  to program warning limits and review minimum and maximum values for  displayed data    One MB of memory provides a generous amount of recording time  with  sampling rates available up to 100 times per second  per channel  Uploaded  data is accomplished through a supplied 6    serial cable  Four threaded studs  on the rear of the dash are providing for mounting  This product is typically  utilized for motorsports not requiring any type of lap timing information     LDX Logger Dash                    nnn 250 KT LDX  Typical Uses  The LDX package monitors   Drag Racing Engine RPM  Driveshaft RPM  Water Temp  Battery Voltage     949  709 5555             DATA RECORDERS    DVd       FEATURES    Channels    37 total   V Net  32 digital analog   Harness  5  engine RPM  driveshaft RPM  water  temperature  oil pressure  volts     Sample Rates    V Net  up to 100 per second   Digital  RPM and switch contacts up to 100 per  second    Recording time depends on number of channels  monitored and sample rates    Dimensions    10 200     L  X 4 000     W  X  750     H     mounting surface to face  2 000    OAL depth     25 908cm X 10 16cm X 1 905cm    Screen dimensions 7 250    X 2 625      18 415cm X 6 6675cm     Weight   25 ou
66. ded or displayed just as you would any function monitored  independently by your Racepak V series recorder  Caution should be exercised to ensure that you do not exceed the maximum  number of V Net channels supported by your particular logger  The individual functions monitored by each EFI system are  outlined in the chart below     For use with Racepak V Net data loggers     EFI Type EFI V Net Module Part Number  Accel DFI Gen VII 230 VM EFIDFI   AEM 230 VM EFIAEM   Autronic SM4 V107  amp  V109 230 VM EFIAUT4    EFI Technologies 230 VM EFITECH    FAST Serial 230 VM EFIFST  Holley EFI  Commander  230 VM EFIHOL    Megasauirt Il 230 VM EFIMS2    Motec M400  M600  M800  M84 230 VM EFIMOTEC  Omniteck EC44 230 VM EFIEC44    WOLF V500 230 VM EFIWOLF          OBDII Data Interface    Provides the ability to gather OBDII data  for data logging or display via Racepaks line  of digital dash Intelli Gauge products   For use with Racepak V Net data loggers        OBDII Module           Contact Racepak for Information    USM Four Sensor Input Module   Provides the ability to input and program up to 4 individual sensors  Each input  has multi function programming capabilities  RPM  analog  temperature or event   Internal terminal strip provides sensor power  12V or 5V  ground  shield and  signal for each input  For use with Racepak V Net data loggers        USM Module    230 VM USM       Racepak temperature sensor cable  144    long  and mating connector      680 CA A144  Racepak pressure s
67. e  logged to your data recorder  It is a real dyno for your car that measures Horsepower   Torque and RPM as accurately as the most respected dynamometers  with the advantage  of being able to gather this data in real world conditions   Torque   Horsepower Sensor                     800 SN TQAEM  Compatible with all Racepak V Net data recorders  Requires use of V Net module     Shift Light    As a companion component to our programmable V Net Shift Light Modules  page  24   Racepak has made available this high intensity LED shift light  The light features a  powerful light emitting diode for luminosity that can t be missed even on the brightest  of race days    Shift Light  Black Housing                  n 800 XP SLBLK    Warning Light   These small warning lights are used as a supplement to the warning issued on the  digital display ofthe Intelli Gauges  The lights provide a bright warning light that is visible  at day or night  and can be remotely mounted in any location  The panel mount light  can be mounted on any flat surface  while the two other stand alone lights incorporate  a built in mounting stand  All models pick up their signal information and power source  directly from the tang on the back of the Intelli Gauges  The stand alone lights have an  aluminum housing that measures 5 8  O D  x 4 1 2  long and stands 2    tall  It is available  with a silver or black finish  Panel mounted light  shown below  features a 3 4  diameter  bulb lens and requires a 11 16  OD r
68. e data transmitted down this single V Net cable  to activate external warning and shift lights  while being  programmed through this same single V Net cable   Now  all programming  warnings  data logging and  data display would be accomplished in a very efficient  manner     Digital Display Dashes   Racepak offers three series of digital displays  the UDX   the G2X and the IQ3  Each utilize Racepak s exclusive  V Net single cable technology  allowing for an extremely  simple installation  while providing a variety of data for  a multitude of motorsports  More information on each  system follows     Intelli Gauges   The Intelli Gauges are a great support component  of the V Net data recording systems  Their unique  capabilities and ease of installation make them  attractive for a variety of performance applications  All  ofthe gauges are 2 5 8  diameter and feature a full 270   sweep needle  a programmable digital display and  electro luminescent lighting  See page 16 for additional  information concerning the Intelli Gauges           INSTRUMENTATION    CLOSED  COURSE    WL  XA Lav Lnd     Racepak am       The UDX is a digital display dash  capable of being utilized with any of Ra   cepak s V Net series of data recorders   With connection to the data logger via the same V Net cable utilized by the  external sensors  the UDX display is capable of    sharing    sensor data with the  data logger  thus providing the ability to display or trigger warnings based on  any internal or 
69. e of the wiring clutter under the  hood  These gauge derive their signal from the data  acquisition system s sensors  so there is no duplication  of wiring or sensors as you would have with other  stand alone gauges        User Programmable warning levels  Download recorded data to PC  Plug and play installation   Analog and digital display  Lightweight  sonic welded  Electro luminescent radial lighting    GAUGES        949  709 5555          INSTRUMENTATION    INTELLI GAUGE SELECTION CHART   Gauge includes connector cable  Sensor and modules available on page 24 30    Cc Y ID NG n        GAU f    OMETER    d    250    250 1G 100    RPM  TAC B  IG 100WB         1 000 10 500RPM   250 IG 100BB     Qu RPM  TURBINE PERCENTAGE  N1 250 1G 218 WB  Lu Vi RPM  TURBINE PERCENTAGE  N2 250 1G 219WB  Mm   TEMPERATURE  WATER  Street  250 1G 110WB  H 3 TEMPERATURE  WATER  Race  250 1G 120WB  UU TEMPERATURE  OIL 250 IG 130WB    2504G 140BB   250 1G 140WB     2504G 145BB   250 G 145WB   NA 50 IG 220WB    250 1G 150WB  250 1G 135WB  250 IG 160WB   50 IG 162WB  250 IG 170WB  250 IG 165WB   50 IG 167WB   50 1G 226WB  250 IG 180WB  250 IG 175WB  250 IG 190WB  250 IG 193WB   50 1G 223WB  250 IG 197WB  250 IG 215WB   50 IG 217WB  250 IG 210WB  50 IG 224WB  50 IG 222WB  250 1G 225WB  250 1G 200WB  250 1G 204WB    250 1G 221WB    TEMPERATURE  CYLINDER HEAD 100   600  F 250 1G 150BB  TEMPERATURE  TRANSMISSION 50   350  F 250 IG 135BB    PRESSURE  OIL 250 IG 160BB  PRESSURE  OIL NA  PRESSURE  FUEL 250 
70. ection that follows  you will find a complete listing of these components  divided into the following categories     Analog V Net Modules     with sensor  pre programmed   without sensor  pre programmed   with sensor  not pre programmed     Digital V Net Modules     with sensor  pre programmed   without sensor  pre programmed   no sensor required  pre programmed              Analog V Net Modules with Sensors  pre programmed     These pre programmed analog function module and sensor combinations are ready for plug and play installation on the       Fuel Pressure 0 75 psi       V Net cable   PRESSURE    Note  All pressure and vacuum modules have a 48    pigtail cable between the V Net module and the sensor    Boost  Manifold  0 75 psi               rrrrse 220 VP PT BST75  Brakes  0 1500 psi                   ninna 220 VP PT B1500  Fuel  Carburetor  0 15 psi                rrrrrsse 220 VP PT CP15  Fuel  Nozzle  0 150 psi bb bb EE RER nn mp 220 VP PT NP150  Fuel  Nozzle  0 300 psi      ccc eee 220 VP PT NP300  Fuel  Nozzle  0 500 psi                       r 220 VP PT NP500  Fuel  Pump  0 75 psi     nee 220 VP PT PP075  Fuel  Pump  0 150 psi 1    cee 220 VP PT PP150  Fuel  Pump  0 300 psi                  rrr 220 VP PT PP300  Fuel  Pump  0 500 psi                rn rrrne 220 VP PT PP500  Nitrous Bottle  1  0 1500 psi                rerrr 220 VP PT N1  Nitrous Bottle  2  0 1500 psi                rre 220 VP PT N2  Nitrous Fuel  1  0 15 psi                  e  220 VP PT NF115  Nitro
71. ed  Digital  4 hard wired  Internal  4    Sample Rates    V Net  up to 100 per second   Analog  up to 1000 per second   Digital  RPM and switch contacts up to 100 per  second    ISUY4NOI  12350125    Memory   Up to 16GB SD Memory Card    Recording time depends on number of channels  monitored and sample rates    Internal Sensors    Battery Voltage   Longitudinal g meter  acceleration and deceleration   Lateral g meter  side to side motion    GPS    Dimensions   5 350     L  X 5 5550   W  X 1 215     H    13 589cm X 14 1097cm X 3 0861cm     Weight   17 ozs    48 kg     G2X Pro    The G2X Pro can utilize any of our three available display dashes  depending upon the user s requirements  The UDX provides 21  programmable inputs  but does not allow the ability to set start finish from the dash  The G2X mini dash  standard G2X dash  allows  the user to set start finish  while programming any two sensor inputs along with shift lights  for display  The IQ3 display dash provides  the 24 programmable inputs  shift lights  warning lights and the ability to set start finsh from the dash         G2X Pro Data Recorder               600 KT G2X PRO  G2X Pro V500 Recorder Mounting Brackets   for 1 250    O D  tubing                        800 MB V500 125  G2X Pro V500 Recorder Mounting Brackets   for 1 500  O D  tubing                       800 MB V500 150  G2X Pro V500 Recorder Mounting Brackets   for 1 625  O D  tubing                   s 800 MB V500 162 Recorder  G2X Pro V500 Recorder Moun
72. eft Front         220 VM RHBLF   Module Only  Ride Height  V Net  Left Rear         220 VM RHBLR   Module Only  Ride Height  V Net  Right Front        220 VM RHBRF   Module Only  Ride Height  V Net  Right Rear       220 VM RHBRR   Sensor Only  Ride Height                         810 SN RHB   G force Sensors  Accelerometer   For years  engineers and enthusiasts have been measuring the longitudinal and   T   lateral forces of a vehicle as a method of evaluating its acceleration  braking  or FRONT    handling performance  You can do the same with these G meters  These G force  sensors can be adapted to any V Net system  Note  V300 4 V500 data recorders all  contain internally mounted G meters   The externally mounted G meter measures  2 0    x 2 0    x 1 250         ccelerometer  d       G force Sensor    G Meter  0 6G     cee eee 220 VP GM  ADAPTER MODULE  V Net Module Only      22222202 2am maman 230 VM AN 12V    Adapts external G meter to V Net cable           Example Puller System    e    TT  TTT    L  a    W  Mat Cable  48    a          103 Logger Dash       Universal Sensor Module    Go X Pro    Recommended for multi engine or vehicles requiring a large number of sensor inputs  Includes  71 channel G2X Pro data logger  power rpm harness  3 RPM sensors  10 magnets  throttle  position sensor  cables and connectors    G2X Pro Puller Kit                          620 KT G2XPROPL     03   Recommended for 4WD  2WD  Super style classes or vehicles requiring an all in one  instrume
73. embly             THERMOCOUPLE ADAPTER MODULES   V Net Module      000c cee 230 VM TC 600  Used to connect the thermocouple sensors  on previous page  to the V Net cable    Interface Module                    n nn n n mm rmm 240 IM TC 600  Used to connect the thermocouple sensors  on previous page  to the Analog port    Pro Analog Plug In Style Transducer                 810 MD TC 500  Used to connect the thermocouple sensors  on previous page  through a Pro Analog Box     Fluid Temperature Sensors   This sensor is commonly used in conjunction with the modules shown below to measure  the temperature of fluids such as water or engine and transmission oil where the temperature  does not exceed 300  F   Fluid Temperature  Sensor Only     0 300  F  for use with V Net modules                        810 TR 300  Fluid Temperature  Sensor Only   0 250  F  for use on Ultra Dash only                     810 TR 250  ADAPTER MODULES  V Net Module 5i  RUE CORREO AA AA 230 VM TR 300  Used to connect the 810 TR 300 sensor to the V Net cable   Interface Module                  2522222222222225253 240 IM FT350    Used to connect the 810 TR 300 sensor to the Analog port     Infrared Temperature Sensors   These infrared sensors are used to monitor temperatures where contact cannot be made  with the item being monitored  In racing  they are commonly used to monitor temperatures  across the face of a tire  but they can be used for any non contact measurement  The  sensor will measure temperatures
74. ensor cable  144    long  and mating connector         680 CA P144    Racepak travel sensor cable  144    long  and mating connector            680 CA M144       STREET    RACEPAKIOMARGWIRE    POWER CONTROL MODULE       Solving the wiring complexity of the modern race car  the Racepak SmartWire  is a fully programmable power control module  While traditional wiring provides  control of vehicle electronic components through the routing of wiring to single  or multiple fuses  relay and circuit breaker panels  the Racepak Smartwire  functions as a central    command center    for all vehicle wiring    Based on Racepak s exclusive single cable V Net technology  the Racepak  SmartWire module is the electronic    starting point     with a direct main power  connection from the vehicle battery to the module  Each input output is then  user defined  both in function  power requirements and current exceeding limits  via a USB connection to the user s PC  The design of the module functions  to both reduce overall installation weight   clutter  while providing a quicker  reacting electronic system  through the solid state switching design    Manual activation is achieved through use of an optional eight switch  Racepak Switch Panel  From the Racepak Smartwire module  a single small  cable is routed to the SwitchPanel  reducing wiring clutter  Users needing  additional switch panel capabilities can easily expand through the use of a     Jumper    cable to a second Racepak SwitchPanel    
75. erface  iui ieee eee eee eee ae 280 CA IM 8P       Pro Analog       Adapts 8 Pin Analog Box to Analog port of V series recorders     Transducer Box  old    style     FRAME RAIL BRACKET  Adapts Pro Analog Box to round tube                800 MB ANA    Transducer Modules  Plug In Stule  Old Stule     When using the Pro Analog Transducer Box these plug in style transducers and signal  conditioning modules are used to convert the input from various analog functions into  signals that can be recognized by the recorder  Where required  a special cable is needed  for connecting the sensor to the module    Pressure Transducer  PSI                810 MD PT  specify psi  Pressure Transducers   Available in ratings of  0 to 1 5 15 30 60 100 150 200 300 400 500 600 1000 1 500  Used  to measure pressure from parameters such as fuel  oil  boost  nitrous  Route your pressure  line directly to the transducer  Transducer has 1 8    NPT female thread    Vacuum Transducer  0 30 In  hg                 810 MD PT VAC   Typically used to monitor manifold or pan vacuum  A vacuum line is routed directly to  transducer    Thermocouple Amplifier Module  0 500  F            810 M TC 500  Cable Only  Thermocouple   Sensor to Module  over 3         800 CA TCEXT XL  specify length   Cable Only  Thermocouple   Sensor to Module  under 3          800 CA TCEXT XX  specify length    Used on low temp applications such as water  oil  cylinder head  Not for use with EGTs   Module  cable and sensor kit available as
76. es  on fuel injection applications        Flow Meter  Gas or Nitro   8AN  1 10 GPM         800 FM AN8 AL  Flow Meter  Gas or Nitro   10AN  2 25 GPM       800 FM AN10 AL  Flow Meter  Gas or Nitro   12AN  2 70 GPM       800 FM AN12 AL  Flow Meter  Methanol   8AN  1 10 GPM            800 FM AN8 SS  Flow Meter  Methanol   10AN  2 25 GPM          800 FM AN10 SS Flow Meter for Methanol    Additional flow meter types and rates available on special order   Flow Meter Tee Fitting   10AN inlet  two  8AN outlets    800 FM TEE       ADAPTER MODULES   V Net Module    rh nnn 230 VM FLOW Flow Meter Tee  Use to connect flow meter to V Net cable    Interface Module    aen nee eee 240 IM FLOW    Use to connect flow meter to digital port of V300 or V500 if no digital wiring harness is being used           RPM   REED SWITCH SENSOR   These contact closure type sensors use an internal  fast acting reed switch to   indicate the passing of a rotating magnet    RPM Sensor  2 Pin  5 16  24 dia                   800 SS PRO 5  Commonly used as a driveshaft RPM sensor on pre 2001 clutch RPM sensor with   Pro Series recorders    RPM Sensor  2 Spade Connectors  5 16  24 dia        800 SS RB 5  Commonly used for clutch  driveshaft and front wheel RPM with SC1000 recorders  RPM 2 Spade Sensor       RPM 2 Pin Sensor       ZERO CROSSING SENSORS    Zero Crossing RPM Sensor  3 Pin  3 8  Dia            800 SS ZX 3  This non powered sensor is designed for monitoring magnetic pulses  It must be   used with an RPM i
77. external sensor in use by the data logger     UDX Display        ssse nnnm hmm 250 KT UDX    UDX Mounting Panels   Trim to fit  vacuum formed plastic mounting panel   Faux Carbon    800 MB UDX PCF   Black         800 MB UDX PBLK   Silver           800 MB UDX PAL          The ap Display Dash can be  utilized with any of Racepak s  V Net data loggers  providing a  compact  fully programmable LCD  digital dash for use in a variety of  motorsports    A single V Net cable is routed to  the rear of the dash  providing power  and access to all sensor information transmitted to the data    logger  Up to 24 different sensor inputs may be displayed on a total of four  programmable pages  The blue backlight provides excellent viewing for both  daylight and nighttime usage  while the low luster display screen provides    excellent protection against scratches     Progressive shift lights  eight warning lights and all inputs are easily    programmable through the Datalinkll software supplied with each data logger   IQ3 Display Dash                rrr aan 250 DS IQ3    I3 External Programming Buttons           FEATURES    Specifications    Display up to 21 sensor inputs via 4 pages   Adjustable backlighting   User defined warning lights  Minimum Maximum recall    Includes   UDX Display Dash    Display Dash Provides   Any 21 sensor inputs   Shift Light Output   Warning Lights    Dimensions    4   H  X 10 2     W  X  75    deep      Requires 2  rear clearance    10 16cm X 25 90cm X 1 90cm   
78. f the cables  V Net cable  connectors are blue  just like the modules to which they  attach  while Interface cable connectors and modules  are black    The cables listed may be used to link the components  to other listed components of the same system  or to  their proper port on the recorder  The Interface cables  with black connectors will only be used with modules  connecting to the RPM or Analog input ports  while the  V Net cables with blue connectors will be used exclusively  on items connected to the V Net port    All V Net systems must be equipped with a Tee cable                                                            6    280 CA VM 006 280 CA IM 006  12    280 CA VM 012 280 CA IM 012  18    280 CA VM 018 280 CA IM 018  24    280 CA VM 024 280 CA IM 024  36    280 CA VM 036 280 CA IM 036  48  280 CA VM 048 280 CA IM 048  60  280 CA VM 060 280 CA IM 060  72  280 CA VM 072 280 CA IM 072  84  280 CA VM 084 280 CA IM 084  96    280 CA VM 096 280 CA IM 096  120    280 CA VM 120  144    280 CA VM 144 280 CA IM 144  192    280 CA VM 192 280 CA IM 192  216    280 CA VM 216    The Tee cable permits the installation of the two terminator caps  one male and one female  which are necessary to the operation of  the V Net system  Just like the ends on the V Net cables  all V Net Tee cables and Terminator Caps are blue    Interface modules can also use a Tee cable  but only for the purpose of providing a branch in the system  It is not a mandatory  component as it is on the V Ne
79. g prefix number of 220 VP PT    220 VS   or 230 VM PT      EXTENSION CABLES   These custom built extensions can be used to extend the length of cables that  use a 2 Pin or 3 Pin Molex connector to attach the sensor to the power harness or a  module   s pigtail  Please specify length required when ordering   2 Pin Molex Cable  Specify Length                   800 CA EXT2P  3 Pin Molex Cable  Specify Length                   800 CA EXT3P    MOLEX TERMINAL KITS   These connector kits can be used if the need arises to shorten a cable that is  terminate  Available with a two or three pin Molex connector  Kit includes both a male  and female connector and pins     2 Pin Molex Connector Kit                nn n nnn 810 CN MOL2  Pin Molex Connector Kit eene eu pu nee 800 CN MOL3  Crimp Tool  for Molex Terminal Pins            800 XP CRIMP 01F       0 75 psi       0   300   F  Temperature    3 Pin Molex  Connector       Connector          Digital V Net Modules with Sensors  Pre Programmed   These pre programmed digital function modules and sensor combinations are ready for plug and play installation on the V Net  cable  See sensors only page     Clutch RPM            i x chee ee eee eee ee 220 VP CL 1  Monitors magnetic pulses using a Zero Crossing sensor   Drive Shaft RPM  Automotive        Contact Closure Sensor                    fr 220 VP DS 2  Contact Closure sensor  includes split collar  magnet  and bracket kit    Drive Shaft Rear Wheel RPM  Motorcycle          220 VP ZXDS 2  Mo
80. gle cylinder  thermocouples is shown below    The most frequently used setup is the four thermocouples with junction box combination shown below  This setup simplifies the  installation on V8 engines by grouping the four thermocouples on each cylinder bank into a common junction box  The junction box  then provides a single wire connection to the V Net module to facilitate service work  A similar setup is available for V6 engines    V Net applications also use two styles of thermocouples  Four cylinder motorcycles make use of the  187 inch diameter tip bullet style  thermocouples  while Harley Davidsons and the automotive applications employ the  250 inch diameter Stinger style thermocouples   When replacing a thermocouple probe  use the  illustration alongside the chart to determine the length  you will need  The thermocouples used with the  junction boxes  and some individual thermocouple                        components that are often requested  are shown in     9           IT  e80 TC400  the chart  See page 20 for single or four station EGT L    X2     f 8001672             modules that include the thermocouples  Dn           00 1Cs413      169    800 TC B316     po    sh  aa aaa   800TC 5418         b  ie 800105319       227   800 TC B3 22     5 To determine the length and   23i              800 TC 54 23     T diameterof a thermocouple   28a          4  800 TC 54 28     b a teste Gn  3o       80 1C5432       g  Set of 4  one of each length     800 TC B3SET            80
81. h RPM    g   x       RPM 2 Pin Sensor       RPM 2 Spade Sensor       or Front Wheel RPM sensor on V series and 2001 and newer Pro Series recorders   Zero Crossing TDC Sensor  3 Pin  3 8  Dia           800 SS TDC 3  This sensor is designed specifically for use with MSD style crank trigger wheel and    magnets  It must be used with a RPM input designed for a zero crossing sensor  Commonly    used for the TDC indicator on ignition timing monitor with V500 recorders  Zero Crossing TDC Sensor       RPM SENSOR APPLICATION CHART    Clutch Driveshaft  Car  Front Wheel TDC Ring Gear  Rear Wheel  Bike   V300 800 55 7X 3 800 SS PRO 5 Cars 800 55 7X 3 NA 800 SS MSC 3  800 55 7X 3 Bikes    V300SD   800 SS ZX 3 800 SS MSC 5 Cars 800 SS ZX 3 800 SS TDC 3 800 S S MSC 3  800 SS ZX 3 Bikes    V500   800 SS ZX 3 800 SS PRO 5 800 SS ZX 3   800 SS TDC 3  800 5S MSC 3  SC1000   800 SS RB 5 800 SS RB 5 800 SS RB 5 800 SS MSC 3       HALL EFFECT SENSOR   Ferrous Material Sensor  3 Pin  3 8    Dia             800 SS MSC 3   Commonly used to sense a ferrous bolt or metal tooth  such as used when monitoring the ring gear RPM  These powered sensors  require 12v power     Magnetic Pulse Sensor  3 Pin  5 16    Dia             800 SS MSC 5  Same as above  but triggered by a magnet rather than a ferrous metal   Adapter Modules  V Net                  rn nnn See page 22    Engine RPM with Magneto Ignition   Occasionally  a V series data recorder will be used to monitor the RPM of an engine that is equipped w
82. h the older DOS programs  Racepak s  Datalink software is a Windows based program               MILLS  W   YY  WM iii               IS    ina   T Taken z T 13         tee 3 o  4    ib Gaur awg ai ep zy el id is        NN       FRM 30823  30407 Esperanza  Rancho Santa Margarita  California 92688  949 709 3333  www RALEPAK  com       
83. ing race engines  Each of these 2 and 4  channel controllers are designed to be connected to the V Net cable of Racepak V series recorders  When ordering please be aware that  the sensors are calibrated for use on specific ports of the controller and cannot be interchanged from port to port without recalibration   All sensors have a 13    pigtail cable  and the controller has a 37    cable for attachment to the sensor  These lengths cannot be altered   Controllers are ordered by cylinder bank layout    Racepak A F sensors are compatible with either gasoline or methanol fueled engines  Gasoline application will display A F ratios  between 9 55 1 and 20 1  while methanol is shown from 4 22 1 to 8 7 1  Please specify the type of fuel you will be using when ordering   Each sensor includes one weldment and plug     AIR FUEL CONTROLLERS  SENSORS MUST BE ORDERED SEPARATELY        2 Channel Controller uneneen RR KKK RK Nu e 220 VM AF2  For use with 2 A F sensors   4 Channel Controller  Cylinders 1  3  5  7         220 VM AF4 1357  For use on 1  3  5  7 cylinder bank of V8  i e  GM 8 Mopar   4 Channel Controller  Cylinders 2  4  6  8         220 VM AF4 2468  For use on 2  4  6  8 cylinder bank of V8  i e  GM 8 Mopar   4 Channel Controller  Cylinders 1  2  3 4         220 VM AFS 1234  For use on 1  2  3  4 cylinder bank of V8  i e  Ford   4 Channel Controller  Cylinders 5  6  7  8         220 VM AF4 5678  For use on 5  6  7  8 cylinder bank of V8  i e  Ford   Air Fuel Sensor Only ahh E
84. ith a magneto ignition  system  In this situation the engine RPM signal is acquired using the inductive pickup shown below  This sensor sources the ignition  pulses between the magneto and the control box  and then transfers the signals to the onboard recorder through the wire harness  or a V Net module   Inductive Magneto RPM Sensor                  280 SN MAGPU   With connector to plug into the V300 wiring harness     Inductive Magneto RPM Sensor                 280 SN MAGPU3 fr e  With connector to plug into the V300SD wiring harness   Inductive Magneto RPM Sensor  ADAPTER MODULE S    ENEE 220 VP TACH  number of pulses  AL      9    Adapts the Inductive Engine RPM sensor to the V Net cable   Magneto Pickup Adapter          MSD Magneto Pickup Adapter   MSD 12 or 20 amp mag                          800 CA MAGADPT  Cable provides easy connection for RPM sensor between magneto and coil     www RACEPAK com       e               m PM DK               D   7 N  O        CSI    La     a ae       NG Y       Exhaust Gas Temperature Thermocouples  V Net systems and V series recorders use two types of thermocouple setups to monitor the exhaust gas temperatures  one for an  individual cylinder application and another for 3 or 4 cylinder groups        Measuring the EGTs on a single cylinder application is accomplished using a thermocouple that features an inline  two prong  mini connector  This connector provides the union between the thermocouple and the V Net module  A selection of sin
85. l affect a car s ability to run on a dial in  has  become an integral part of tuning a car  In order to make  proper decisions related to the weather you need a quality  weather station  As a service to our customers Racepak  is pleased to be able to offer one of the best  the AltaCom  Il weather station by AltaLab Instruments  This weather  station is used by profession and sportsman racers in  NHRA  IHRA  NASCAR  SCCA  Formula    and offshore  boat racing    The AltaCom Il is designed for superior infield operation   From sensor specification and board design to the remote sensing  paging functions  and software  the AltaCom Il is  manufactured to provide you with stable  accurate data  Of particular importance to those who use a Racepak data recorder  is the ability of the AltaCom Il to import it s weather data right into the Racepak run files    The trailer based AltaCom Il monitors the four prime weather parameters using amast mounted  fan aspirated remote sensor  station  From the four prime parameters it then calculates seven other weather values  Each value is updated every 20 seconds   The optional pager allows you to stay current with changing conditions even when you are away from the console s LCD display           Shown above is the AltaCom II display console  pager  and remove  sensor station     AltaCom II Kit Monitors  AltaCom II Kit Calculates   Temperature Density Altitude  Absolute Barometric Pressure Adjusted Altitude  Relative Humidity Grains of Water  Am
86. link the components  to other listed components of the same system  or to  their proper port on the recorder  The Interface cables  with black connectors will only be used with modules  connecting to the RPM or Analog input ports  while the  V Net cables with blue connectors will be used exclusively  on items connected to the V Net port    All V Net systems must be equipped with a Tee cable     The Tee cable permits the installation of the two terminator caps  one male and one female  which are necessary to the operation of  the V Net system  Just like the ends on the V Net cables  all V Net Tee cables and Terminator Caps are blue    Interface modules can also use a Tee cable  but only for the purpose of providing a branch in the system  It is not a mandatory  component as it is on the V Net system  The black Interface Tee cables and dust caps are used just for the purpose their names imply   They are not required for the system to operate properly    Bulkhead connectors are used when a V Net or Interface cable must pass through a firewall  body panel  or motor plate  They  provide a male female connector on each side of the panel  These are specific to the type of cable that is being used and are color    coded for easy identification                                e 280 CA VM 006 280 CA IM 006  280 CA VM 012 280 CA IM 012  280 CA VM 018 280 CA IM 018  280 CA VM 024 280 CA IM 024   36    280 CA VM 036 280 CA IM 036  48    280 CA VM 048 280 CA IM 048  60    280 CA VM 060 280 
87. ly a miniature computer  which houses circuit boards and a microprocessor that identifies and retrieves only the proper  incoming signals and allows other signals to pass through    Whether you will be installing a single gauge set up  or a full blown data acquisition system  all components are attached to the  system using the modular snap together connectors  Adding components onto the system is simple  Just find a Junction in the main  V Net cable  separate the connectors  and sandwich the new sensor s module between them  Then command your software to read  the new configuration  It will  automatically recognize any DIGITAL ANALOG V NET V300SD DATA RECORDER  additions or deletions from the PORT PORT PORT contains three internal sensors     Longitudinal G meter  Accelerometer   system      Lateral G meter  side to side   Battery Voltage  Gauge integration is    V Series Recorders  another strength of the V Net  system  but don   t mistake the  Racepak gauges for garden  variety gauges  If your vehicle  is equipped with a V Net  recording system  the gauges  simply use the sensors and  wiring that are already in place  to provide full time display of  the data being monitored   The same holds true for    Terminator Cap Cy    mag    m FHHEBHEHEHEHEEE SB  Four Available High Speed Analog Channels  V Net  These channels are usually reserved for monitoring functions Tee Connector  that require sample rates faster than 100 samples per second                  DIGITAL  RPM   WIRIN
88. mer Service representative at 949 709 5556 or check out  www racepak com     pa BR CT CL  s     dl      wa          www RACEPAK com                   LA  Ld  L4  DATASY STEMS    www racepak com        949  709 5555    Introduction Lili    2 3    ADDIIGAlo RCA  tecuecaee huge ERU RAN SURE TA RUE genase 4  BIC Ve W   5 34  Closed Course  35 58  woe AA AA AA AA 59  Ci  APP PA AA 60 64  MOUNINO  garo 2 amA AA shen BA nane INDIANA iran 65 66  Download Hardware                  67  NAGO ENEE 68 69  DOING s ca AE ME ene Gas eae haa ew nee esd AA Hes oP NE 70 72  Weather Stations    73 74  ADDSIel vs o54 ans uehs ener se AA 75  Adding Sensors to a GPS Logger                         76  Example Schematics          onnaa eee Lf  GICSSAIY AA AA 78 79  Payment    All orders are credit card or wire transfer  All international orders are wire transfer  Credit Cards   are the preferred method of payment  Racepak accepts Visa MasterCard and Amex  When paying  by credit card be sure to include card number  expiration date  and name of card holder  Checks   If prepaying by check please allow ten days for the check to clear your bank  Bank Drafts  If  paying by bank draft allow three days for transmission of the draft to our account  International  accounts allow five days  Also please remember to include sufficient funds to cover the amount  deducted by the bank for transfer fees     Shipping   Racepak s primary method of shipping is via Fed Ex  This includes all forms of Fed Ex delivery  opti
89. nce Group  Known as the leader in high   performance ignition and electronic products  MSD Ignition offered the perfect  environment for Racepak   s continued growth    The team at Racepak Data Systems is proud of our accomplishments and the  reputation we have developed in the motorsports community  We firmly believe  that reputation is the key to our success  Racepak continues to follow the  same guiding principles that have led us to the forefront of the data acquisition  industry  Our unwavering goal remains to produce reliable  efficient  state of the  art data recorders  It is key that they remain at a price accessible to professionals  and sportsmen alike and that we support our customers with whatever service  they may need  Our push for continual product advancement  dissatisfaction  with status quo  and the burning desire to achieve the impossible  have made  us a perfect match for the customers we serve    Finally  we wish to thank our customers who have played an integral role  in the growth of Racepak  It is through your faith in us  and the input and  Ongoing support of our products  that we have become the leader in data  acquisition  We value that relationship and look forward to further cultivating  itas we continue to grow    Racepak systems are designed to take the intimidation factor out of  purchasing a data acquisition system  Further  we are always available to  answer any questions or provide component selection advice  You can contact  a Racepak Custo
90. nces  71 kg        The LDX Logger Dash package includes     LDX Logger Dash   Wiring harness   Driveshaft RPM sensor kit   Datalink download software kit with 6 foot cable  V Net tee connector with terminator caps   Water temperature sensor   Oil pressure sensor   Instruction manual          When Racepak introduced their series of V Net  data loggers  which allows all sensors to transmit  their data back to the data logger via a single cable   the next logical progression in this technology was to  add the ability to plug gauges and dashes into this  same V Net cable  By doing so  this would allow the  gauge to share the sensor information with the data  logger  thus providing a true    vehicle network    of data  logger  sensors and gauges  all routing their data  through a single cable  This design has proven to be  tremendously popular  as the installation  weight and  complexity of data systems and related components  was greatly simplified     Taking this design a step further  this line of    Intelli   Gauges    and LCD Digital Display Dashes could now  use the data transmitted down this single V Net cable  to activate external warning and shift lights  while being  programmed through this same single V Net cable   Now  all programming  warnings  data logging and  data display would be accomplished in a very efficient  manner     Digital Display Dashes   Racepak offers three series of digital displays  the UDX   the G2X and the IQ3  Each utilize Racepak   s exclusive  V
91. nderstanding of what the chassis is doing   The information obtained from these sensors is often the key element separating the winners from  the losers  regardless of the type of racing  Racepak users can employ these linear potentiometers  to record the slightest amount of suspension movement  even at high rates of speed  Shock travel  sensors are usually connected through the analog port of V series recorder and monitored at a high  sample rate    Each kit contains a linear travel sensor with attached cable and an Interface module  An available  analog channel is required for each sensor  A separate kit is required for each wheel monitored   Kit  Front Shock Travel  V Series       Data Recorders  0 4                rrr rrr rrn nnn 280 KT SHKTRVF  Kit  Rear Shock Travel  V Series   Data Recorders  OB  bb eee 280 KT SHKTRVR   Uses Interface module for connection to hardwired analog port of V300 or V500   Sensor Only  Shock Travel  0 2      7 4    to 9 4                 800 LN TRV2  Sensor Only  Shock Travel  0 3      8 4  to 11 4                800 LN TRV3  Sensor Only  Shock Travel  0 4     Front   9 7  to 13 7          800 LN TRV4       Sensor Only  Shock Travel  0 8     Rear   12 6    to 20 6           800 LN TRV8  Dimension in parenthesis is compresses and ext ended eyelet center to center distance   Interface Module Only                     nnn rrr See page 26    Linear Travel Sensors   These linear potentiometers are used to monitor movement or position  They are commo
92. nitors magnetic pulses using a Zero Crossing sensor    Front Wheel RPM                         nnnm mmm 220 VP FWZX  Monitors magnetic pulses using a Zero Crossing sensor    Front Wheel RPM                      nnm mmm 220 VP FWHE3 Driveshaft RPM  Monitors ferrous metal pulses using a Hall Effect sensor    Turbo Speed     cence 220 VP TURBORPM  for use with Racepak V Net Data Loggers   Turbo Speed V Net Module only                 230 VM TURBO   Turbo Speed Sensor only                    rene 800 SS SPEED    Digital V Net Modules uithout Sensors  Pre Programmed   These pre programmed digital function modules are ready for plug and play installation on the V Net cable  You must add the  appropriate sensor to the module        Zero Crossing Input  see page 55                   230 VM ZX 1  Hall Effect Input  see page 55                      230 VM RPMHE  Contact Closure Input  see page 55                230 VM CC 1  Event Marker Input  12 Volt                rerrns 230 VM EVENT  Event Marker Input  Switch Closure            230 VM EVENTSW  Flow Meter  see page 54                           230 VM FLOW  Four Channel Digital Input    RRE nb mm 230 VM 4DIGIN  Four Channel Digital Output                   230 VM 4DIGOUT Zero Crossing Input    Digital V Net Modules  No Sensor Required  Pre programmed   These modules do not require a sensor  They use the pulse from the component they are monitoring as the signal to the module  Each  has been programmed for the specific use noted and i
93. nly used  on applications such as magneto retard devices  fuel slide valves  and linear clutch bearing position   Their use requires an appropriate signal conditioning module     Front Shock  Travel       Linear Travel Sensor  0 1 0              rrr rrr nn 800 LN FUEL  Typically used to monitor pneumatic magneto retard or slide valve fuel system controller   Linear Travel Sensor  0 3 0               cce n ene 800 LN CLV3  Typically used to monitor the movement of a clutch throw out bearing   ADAPTER MODULES  Use these modules to adapt travel sensors to V series recorders   V Net Module  see this page                         230 VM TPS  For connection to V Net cable on V series recorders   Interface Module  see page 23                     240 IM TRAV Linear Travel    For connection to Analog port of V300 or V500 recorders  Sensor    STRING POTENTIOMETER    This sensor is typically used for linear measurements  such as throttle position  when the mounting  angle is not critical  The sensor is calibrated to the travel of the throttle  i e  096 when closed and 10096  at WOT   By using a string potentiometer  the possibility of interference with the throttle operation is  eliminated  Operating range 0 4 750      String Potentiometer Sensor                   800 LN STRINGP  ADAPTER MODULES  Use these modules to adapt string potentiometers to V series recorders   V Net Module  see page 20       000cn nen 230 VM TPS  For connection to V Net cable on V series recorders   Interface Mod
94. nput designed for a zero crossing sensor  Used as the clutch Zero Crossing RPM Sensor   RPM or Front Wheel RPM sensor on V series and 2001 and newer Pro Series   recorders    Zero Crossing TDC Sensor  3 Pin  3 8  Dia           800 SS TDC 3  This sensor is designed specifically for use with MSD style crank trigger wheel and    magnets  It must be used with a RPM input designed for a zero crossing sensor  Commonly  used for the TDC indicator on ignition timing monitor with V500 recorders  Zero Crossing TDC Sensor          800 SS ZX 3 800 SS PRO 5 cars 800 SS ZX 3 NA 800 S S MSC 3  800 SS ZX 3 Bikes   800 SS ZX 3 800 SS MSC 5 Cars 800 SS ZX 3 800 SS TDC 3 800 S S MSC 3  800 SS ZX 3 Bikes    800 SS ZX 3 800 SS PRO 5 800 SS ZX 3   800 SS TDC 3  800 5S MSC 3  800 SS RB 5 800 SS RB 5 800 SS RB 5 800 SS MSC 3       HALL EFFECT SENSOR   Ferrous Material Sensor  3 Pin  3 8    Dia             800 SS MSC 3  Commonly used to sense a ferrous bolt or metal tooth  such as used when monitoring the ring gear RPM  These powered  sensors require 12v power     Magnetic Pulse Sensor  3 Pin  5 16  Dia             800 SS MSC 5  Same as above  but triggered by a magnet rather than a ferrous metal    Adapter Modules  V Net                  nn nnn See page 22   ADAPTER MODULE   Vo iiia eee se ee ee ee ee ee ee ee a 220 VP TACH 4    Adapts the Inductive Engine RPM sensor to the V Net cable     MSD Magneto Pickup Adapter   MSD 12 or 20 amp mag  800 CA MAGADPT  Cable provides easy connection for RPM senso
95. ntation data logger design with 32 sensor inputs  Includes 32 channel IQ3 Data  Logger Dash  four sensor input module  3 RPM sensors  10 magnets  throttle position sensor   cables and connectors    IOS PUNGI EE 620 KT IQ3LDPL  IQ3 Puller Kit AWD                           620 KT IQ3LDPL4    GeX    Recommended for pulling vehicles requiring 12 or less external sensor inputs  Includes 12  channel G2X data logger  four sensor input module  3 RPM sensors  10 magnets  throttle  position sensor  cables and connectors    G2X Puller Kit                              620 KT G2XRNDPL    Above are recommended data system kits for the pulling competitor  Racepak offers a  number of data loggers and sensors  to fit your pulig needs  Refer to the Drag section of this  catalog  for additional sensor and data logger products     Terminatar  Cap                   Disp       STREET    Taking the technology from our race proven LCD dashes and applying it to FEATURES  the street vehicle market  the UDX Street Rod Dash is a complete dash panel  replacement  Containing all the amenities required on a street driven vehicle     this product provides all the information necessary for highway use  Specifications   aa si     Display up to 21 sensor inputs via 4 pages   Through a combination of your existing sensors and those included with Adjustable backlighting   this kit  the dash will provide the ability to display engine RPM  speedometer  User defined warning lights  odometer  water and oil temperatu
96. ntrol Module   A Relay Control Module is the device which permits the V Net system to perform  a host of automated tasks  It allows any information transmitted over the V Net to be  used to activate external high power devices such as a switch  solenoid  water pump   fan  or lights  Each module has two programmable output relays    Each relay can have up to two separate  analog and or digital  control signals that  must be met before the relay is engaged  For example  one relay can be programmed  to turn on a water pump only when a    Pump    switch is on and the water temperature  is above the programmed value  while the other relay can be used to activate an  ignition kill switch only if the engine RPM is above a programmed value and the oil  pressure is lower than a predetermined pressure  Relays are included    Relay Control Module                 rn rnnnn 230 VM RELAY    Steering Sensor   Column mounting steering sensor package includes rotary sensor  column mount   billet contact wheel and V Net module   For use with Racepak V Net data loggers    Steering Sensor Package                 r rn nn 220 VP SK 1       2 Channel Air Fuel  Controller       Relay Control  Module             Interface Modules   Interface modules are another unique component of the V series recorders  These black 7 pin modules differ from the blue 5 pin  V Net modules in both the application and the manner in which they perform  They are designed to provide a modular method of  assembly for the sen
97. omputer  This makes it easy to view and select just the portion of the video you want to integrate into your run file    To equip your data acquisition system for integrated video display  your computer will need to be equipped with Racepak s Windows     based Datalinkll Standard  or higher version  software  Along with this you must purchase the Racepak Video Capture software  an  IEEE 1394 Firewire card that is OHCI  open host controller interface  compliant  plus the logger configuration set up for video support   These items can be purchased as a kit using the one of part numbers below   Data Acquisition Video Kit     for desk top computers                    890 UG VIDEOPCI  Data Acquisition Video Kit   for laptop computers                      890 UG VIDEOPCM    Data Acquisition Video Software  amp  Manual Only    890 UG VIDEO  890 UG VIDEO is for computers that are already equipped with the Firewire components     Additionally you must purchase separately a digital video camera  Mini DV format only  with IEEE 1394  also known as Firewire or  iLink      The Racepak Video Capture software lets you display and review your video recording to select just the portion you want to integrate  with your onboard data    For more information on Racepak s video software package  or for answers to question you may have about this system  please  contact Racepak s Technical Department     Minimum computer system requirements for use of intregrated video software    600 MHZ  Pentium I
98. onents interact with each other  making a  simpler  more compact system which can be expanded with ease    The key to accomplishing this is in the modular connectors that attach each of the devices to the main V Net cable  Each module  is essentially a miniature computer  which houses circuit boards and a microprocessor that identifies and retrieves only the proper  incoming signals and allows other signals to pass through    Whether you will be installing a single gauge set up  or a full blown data acquisition system  all components are attached to the  system using the modular snap together connectors  Adding components onto the system is simple  Just find a Junction in the main  V Net cable  separate the connectors  and sandwich the new sensor s module between them  Then command your software to read  the new configuration  It will  automatically recognize any DIGITAL ANALOG YANET      additions or deletions from the Ore GORE NM Lc m  system      Lateral G meter  side to side   Battery Voltage   f     V Series Recorders   Gauge integration is  another strength of the V Net  system  but don t mistake the  Racepak gauges for garden  variety gauges  If your vehicle  is equipped with a V Net  recording system  the gauges  simply use the sensors and  wiring that are already in place  to provide full time display of  the data being monitored    The same holds true for  Racepak s digital display di nn  dashes  Some models of a  the dash will rely solely upon  the data recorder   
99. ons for domestic and international services  Please specify which method you prefer at the time  of your order  If a method is not specified Racepak will use the least expensive option available   Requesting a shipping carrier other than Fed Ex will incur additional charges  All shipping charges  are the responsibility of the customer and will be added to the invoice     Warranty   Racepak CSI Data Systems makes every effort to insure that our products and services are of  the highest quality and standards  It is our intention to maintain a mutually beneficial and cordial  relationship with each and every one of our customers    Racepak CSI warrants all merchandise manufactured by Racepak against defects in workmanship  or materials for a period of six months after the date of purchase  This warranty applies to the first  retail purchaser and covers only those products exposed to normal use or service  It does not apply  to those products used for a purpose for which it was not designed  or which has been altered in any  way that would be detrimental to the performance or life of the product  or misapplication  misuse   negligence  or accident  Any part or product found to be defective after examination by Racepak will  be repaired or replaced  Racepak assumes no responsibility for diagnosis  removal and or installation  labor  loss of vehicle use  loss of time  inconvenience or any other consequential expenses    This warranty is in lieu of any other expressed or implied war
100. ound hole for the bulkhead style mounting  Warning  Lights can be used in conjunction with any Intelli Gauge   Warning Light  Stand alone  Black Housing         800 XP WLBLK  Warning Light  Stand alone  Silver Housing         800 XP WLSLV  Warning Light  Dash Mount                      800 XP WLDASH          Torque    Horsepower  Sensor    Warning Light          NAGANA SNANG    POWER CONTROL MODULE       Solving the wiring complexity of the modern race car  the Racepak SmartWire  is a fully programmable power control module  While traditional wiring provides  control of vehicle electronic components through the routing of wiring to single  or multiple fuses  relay and circuit breaker panels  the Racepak Smartwire  functions as a central    command center    for all vehicle wiring    Based on Racepak s exclusive single cable V Net technology  the Racepak  SmartWire module is the electronic    starting point     with a direct main power  connection from the vehicle battery to the module  Each input output is then  user defined  both in function  power requirements and current exceeding limits  via a USB connection to the user s PC  The design of the module functions  to both reduce overall installation weight   clutter  while providing a quicker  reacting electronic system  through the solid state switching design    Manual activation is achieved through use of an optional eight switch  Racepak Switch Panel  From the Racepak Smartwire module  a single small  cable is routed to 
101. our  Datalinkll software     Voltage  0 5 Volt Input  5 Volt Output              230 VM AN 5V   Voltage  0 5 Volt Input  12 Volt Output            230 VM AN 12V   Pressure  5 Volt  see sensors page 25             230 VM PT 5V   Position Movement  Rotary or Linear                230 VM TPS   Temperature  Fluid type  0 300F                230 VM TR 300  For use with Racepak sensor  810 TR 300 only  see page 28    Temperature  Low  0 600 F                       230 VM TC 600  For use with type K thermocouples only  see page 27    Temperature  High  0 1800  F                    230 VM TC 1800  For use with type K thermocouples only  see page 27    Air Fuel Sensor Input  Single                         230 VM AF   Air Fuel Sensor Input  4 Station              230 VM AF  cyl  s    Battery Voltage         nee 230 VM BVOLT    Voltage Differential bb bb RR eee 230 VM 5VDIFF       EGT Cylinder 1       Voltage 0 5 Input             Analog V Net Modules with Sensors  NOT pre programmed    The module sensor combinations are the same as the V Net Modules with Sensors Analog on pages 19 20 with the exception that  they have not been pre programmed  Each of the pressure or temperature module sensor combinations below is designed to be  attached to the V Net cable  Once installed  they must be programmed using the Configuration File in the Datalink software     PRESSURE   0 15 PS  eege iaia denim 220 VS 15GVT   TALA AA AA xA NA TY TAY 220 VS 75GVT  0 150 psi   ica AA 220 VS 150GVT  0 900 POL  
102. own in     9 IT 800 TC S 4 09    the chart  See page 20 for single or four station EGT     I      800TCB32             modules that include the thermocouples  L  n           80017C  4313   pO      800 TC B3 16           NL   ca i a aa  809TC5421     22         800 TC B3 22        To determine the length and EC 800 TC 54 23   diameter of a thermocouple 28    __   800 TC 54 28  measure as shown    3m   800705432   S et of 4  one of each length  800 TC B3 SET           J       800 TC 54 SET1   2 each  9     13     18   23      Set of 8 Big block Heads D 800 TC S4 SET2   two of each length noted  B sets  1 each  18     23     28     32      Tae Heads D 800 TC 54 SET3  sets        a Naa aaa  a ds      aaku E    Diameter     1 each  13     18     21     28        Special Purpose    Thermocouples  These Type K thermocouple assemblies  Nickel  Weldment  Nut  amp  Ferrule Assembly   800 TX WASM3   800 TX WASM4           A i Weldment Only  Single     800 TX WELD4  Chromium Nickel Aluminum  are specifically designed Weldment Only  Single  Stainless    800 TX WELD4SS    for the applications listed below  Each SI be used  Weldment Only  Seto4     800 TX WELD404    with the appropriate thermocouple amplifier module  WeldmentOnl Setof8     800 1X WELD408_  All probes are 12    in length and are terminated with a FemleOny TT 800 TX F4    male two pin mini connector  The liquid and manifold Nutony          800 TX WNUT4    assemblies are provided with a 1 8    male NPT  Cap Ony             800
103. pak data loggers and Chasecam PDR100 camera recording with    this programmable V Net module   840 REPLAYXD    Chasecam Module                        230 VM CHASECAM    SIS Camera Start Record Module    Sync Racepak data loggers and SIS 840 HDX 1 camera recording with this  programmable V Net module     SIS Camera Module                    sss   230 VM SISCAM  Trackvision Software    Overlay Racepak data over video  Create customized dash panels  save   export for online video replay    Trackvision System Package                  890 UG VIDEOAO       Integrated Video Software    Merge your onboard video with Racepak Data  Contact Racepak for details                D  Li   a   List Meu mea is Ma Ee zem li 3    ps  Pini LET pp Papa np Fam uu ise  sE      glia et  ima                   fm nia m    H Dad mem   um  Sa            3 Gi dd vi aa    t   a     mxeemcmm eus      e                                                              aff shee    dri qim eset iu                TEO       Integrated Video   With this option it is possible for you to combine and synchronize the video you shoot of each run with the data that is collected by  the onboard recorder  No longer will it be necessary for you to try to align to two with each other in order to obtain a visual image that  enhances the onboard information you have collected    This program allows you to control Play  Stop  Fast Forward  Rewind  and Frame Step functions within the video capture software using  the mouse of your c
104. r  pre programmed   without sensor  pre programmed   no sensor required  pre programmed           Analog V Net Modules with Sensors  pre programmed     These pre programmed analog function module and sensor combinations are ready for plug and play installation on the       Fuel Pressure 0 75 psi       V Net cable   PRESSURE    Note  All pressure and vacuum modules have a 48    pigtail cable between the V Net module and the sensor    Boost  Manifold  0 75 psi             anananan 220 VP PT BST75  Brakes  0 1500 psi                   rnnn 220 VP PT B1500  Fuel  Carburetor  0 15 psi    cee 220 VP PT CP15  Fuel  Nozzle  0 150 psi ww    eee 220 VP PT NP150  Fuel  Nozzle  0 300 psi been RRE ER kW 220 VP PT NP300  Fuel  Nozzle  0 500 psi      2222aaaaanannanan 220 VP PT NP500  Fuel  Pump  0 75 psi    eee 220 VP PT PP075  Fuel  Pump  0 150 psi      00 cee ee 220 VP PT PP150  Fuel  Pump  0 300 psi      0c cee 220 VP PT PP300  Fuel  Pump  0 500 psi ccc cee 220 VP PT PP500  Nitrous Bottle  1  0 1500 psi   cn 220 VP PT N1  Nitrous Bottle  2  0 1500 psi                rerrs 220 VP PT N2  Nitrous Fuel  1  0 15 psi ww  cee 220 VP PT NF115  Nitrous Fuel  2  0 15 psi ww  nee 220 VP PT NF215  Nitrous Fuel  3  0 15 psi              rrr 220 VP PT NF315  Nitrous Fuel  4  0 15 psi    wee 220 VP PT NF415  Oil  0 150 psi ww wee 220 VP PT OP150  Oil  0 300 psi 2    eee 220 VP PT OP300  Pressure Differential  0 40    H O to 15 psi        220 VP PT PD145  Transmission  0 300 psi                       2
105. r between magneto and coil        Magneto Pickup Adapter             Exhaust Gas Temperature Thermocouples  V Net systems and V series recorders use two types of thermocouple setups to monitor the exhaust gas temperatures  one for an  individual cylinder application and another for 3 or 4 cylinder groups     Measuring the EGTs on a single cylinder application is accomplished using a thermocouple that features an inline  two prong  mini connector  This connector provides the union between the thermocouple and the V Net module  A selection of single cylinder  thermocouples is shown below    The most frequently used setup is the four thermocouples with junction box combination shown below  This setup simplifies the  installation on V8 engines by grouping the four thermocouples on each cylinder bank into a common junction box  The junction box  then provides a single wire connection to the V Net module to facilitate service work  A similar setup is available for V6 engines    V Net applications also use two styles of thermocouples  Four cylinder motorcycles make use of the  187 inch diameter tip bullet style  thermocouples  while Harley Davidsons and the automotive applications employ the  250 inch diameter Stinger style thermocouples   When replacing a thermocouple probe  use the  illustration alongside the chart to determine the length  you will need  The thermocouples used with the  junction boxes  and some individual thermocouple    components that are often requested  are sh
106. rall timing  or  individual cylinder timing on those vehicles using the proper programmable  ignition system  with optional timing package        V500 with data cartridge download and Datalink Standard  200 KT V500 AMDC    Typical Uses  The V500 package monitors  The V500 package includes   Pro Mod Engine RPM V500 Data Recorder  Pro Stock Driveline RPM Driveshaft or rear wheel RPM sensor with split collar and magnet kit  Drag Boats Engine v  Driveline RPM differential Datalink software kit with serial programming download cable  Dynamometers Battery voltage V Net tee connector with terminator caps  Industrial equipment Acceleration g force  clutch RPM optional   Lateral g force Power Ground Engine RPM Driveshaft Harness  clutch RPM optional upgrade     G2X Pro V500 Recorder Mounting Brackets     for 1 250    O D  tubing                         800 MB V500 125  G2X Pro V500 Recorder Mounting Brackets    for 1 500  O D  tubing                         800 MB V500 150  G2X Pro V500 Recorder Mounting Brackets    for 1 625  O D  tubing                         800 MB V500 162       G2X Pro V500 Recorder Mounting Brackets     for 1 750  O D  tubing Recorder Mounting Brackets     949  709 5555       DATA RECORDERS       SPORTSMAN FEATURES  DRAG RACE DATA LOGGER Channels     21 total   8 EGT  V Net    7 internal  amp  external  6 V Net    DRAG    Sample Rates   V Net  up to 100 per second    Memory    SD memory card   Up to 8MB SD card   Record multiple runs before download    Internal
107. ranties  including any implied warranty  of merchantability or fitness  and any other obligation on the part of Racepak  or selling dealer           APPLICATION LDX   V300  amp    V500 G2X   IQ3 Logger   Sportsman  DASH   V300SD    _ EE    Drag Race Pulling EDEN            Pro Mod  Blown or uM  Nitrous    Pro Pro Stock     Li ie Eliminator  Blown or Unblown   Super Stock  Stock   Brackets   Drag Boat  Blown or   Unblown  Gas  Alcohol   Motorcycle Blown Fuel      Motorcycle Nitrous            I      Land   Land Speed Vehicles   Vehicles    EET Course   Requiring Lap Timing       Circle Track     NASA    meme           ot ft  Gite fe IL  Perl   Boat  Ofshore   f    Bei Other TTT  Weck f p  oer __ _                            Www  A eromotivelnc  com         POWER CONTROL MODULE       E Sa       Solving the wiring complexity of the modern race car  the Racepak SmartWire  is a fully programmable power control module  While traditional wiring provides  control of vehicle electronic components through the routing of wiring to single  or multiple fuses  relay and circuit breaker panels  the Racepak Smartwire  functions as a central  command center  for all vehicle wiring    Based on Racepak s exclusive single cable V Net technology  the Racepak  SmartWire module is the electronic  starting point   with a direct main power  connection from the vehicle battery to the module  Each input output is then  user defined  both in function  power requirements and current exceeding limits  via
108. re  oil pressure  battery voltage and fuel Minimum Maximum recall   E  level  Indicator lights are included for items such as low oil pressure  high water Turn signal  high beam  engine warning lights  temperature  turn signals  high beam and parking brake  Additional features can  be displayed with the purchase of th iate V N d modul VIGILIO    e displayed with tne purchase of the appropriate V Net sensor and module UDX Street Rod Display Dash  combination  A relay for an electric fan controller along with a minimum maximum Water Oil temperature sensor  recall function is included  Oil pressure sensor  UDX Street Rod Display Dash Instrument Panel  Wire loom and connectors for sensor input  Street Model               resistito 250 KT UDXSR E    Display Dash Provides Viewing of   Any 21 sensor inputs recorded be the data logger  ohift Lights   Warning Lights    Dimensions    4   H  X 10 2   W  X  75   deep      Requires 2  rear clearance    10 16cm X 25 908cm X 1 905cm     Weight   21 ozs    58 kg     UDX Street       The UDX SR Dash provides turn signals  high beam indicator   and even parking brake warning lights             UDX Mounting Panels   Trim to fit  vacuum formed plastic mounting panel    Faux Carbon  4222222299653 E ee E 800 MB UDX PCF  Black CA ni niet 800 MB UDX PBLK  AA AA AA ee 800 MB UDX PAL       www RACEPAK com    UDXIDISPIAVDASH       The UDX is a digital display dash  capable of being utilized with any of Ra   cepak s V Net series of data recorders   With
109. readsheets  x y plots   histograms  gauges  and more     PC Requirements    200 MHZ  Pentium Il  CPU    Large screen monitor with 1024 x 768 pixel minimum resolution   200 MB of available hard drive space   Windows  XP Vista and Windows 7 operating system    16 MB of RAM    One available RS 232 serial port  or USB to serial cable adapter    CD ROM drive     If you will be using the data cartridge download system your computer must have a USB port and be equipped with Windows  98  ME  2000  XP Vista  or  Windows 7  32 bit operating system         cr r    pe D  0A Ba  XP  se  AM A Ln zeg    ON Mobil       270 EN 3M cun   c  ate ED ARP   d se UNOH FAS TIMKEN  MAHLE Sale Pa           The graphics on page 39 and 40 are typical of the screen views  you will see when using the Datalinkll data analysis software  If you  currently use a computer you will already be familiar with many  of Datalinkll s Windows   based navigational tools  Displaying  additional channels or files  or maneuvering around the program   is simply a matter of point and click on the icons  An extensive   easy to understand  instruction manual  plus online help  are also  included with all Datalinkll data analysis programs  Check out a  few of the great Datalinkll features     Fle Edt  eege Furnlog Track Map  View Senor Geet Hep  4 Graph   GI AATLO22802R4  SIT    line Reg   ma  io movi tos Jtr  ieee   ise  oen Joe  nas iaa jos Inge iat _ Joo  be Beta  tn Dass ni  nitorem x  umts jera  o  es 51  rano  MAN nes mas
110. s  NOT pre programmed    The module sensor combinations are the same as the V Net Modules with Sensors Analog on pages 19 20 with the exception that  they have not been pre programmed  Each of the pressure or temperature module sensor combinations below is designed to be  attached to the V Net cable  Once installed  they must be programmed using the Configuration File in the Datalink software     PRESSURE   0 15 PS  circa 220 VS 15GVT   0 79 PSI anice EE EE 220 VS 75GVT   0 150 psi istic ieee cette cee ERE REESE E 220 VS 150GVT   0 300 DSI  iii RARA RE EAE 220 VS 300GVT   O 500 OS  cits tiene rien 220 VS 500GVT   0 1500 psl oa kc ee ee ER E AA 220 VS 1500SVT   Vacuum Pressure  30 In  hg 0 30 psi                    220 VS VB  To measure pressure functions using sensors seen on page 28    TEMPERATURE   Fluid Temperature   Temperature  0 300  F  Fluid type Sensor           220 VS TR 300    Uses the  810 TR 300 sensor seen on page 57     QUICK DISCONNECT TERMINAL KIT  Thee connector kits provide you with the components that will allow you to  shorten the pigtail cable between the V Net module and pressure sensor or a TR   type temperature sensors  Each kit includes enough components for one module   Fluid Temperature Sensors                            810 CN TR2P  Use with V Net modules and temperature sensors having prefix number of 220 VP   TR   220 VM TR   or 230 VM TR    Pressure Sensors                rrrhhhrhhhhhn 810 CN TI3P  Use with V Net module and pressure sensor havin
111. s ready for plug and play installation on the V Net cable     ENGINE RPM     Programmable to read from multiple cylinders applications    Engine RPM Input Module                        220 VP TACH 4    EVENT INPUT  Transbrake Event  12 volt Triggered     monitors transbrake solenoid                 220 VP TBRAKE  Wide Open Throttle Event  On Off Switched Input     See switch page 28                         220 VP WOTEVENT  Clutch Event  12 volt Triggered     Monitors two step clutch pedal switch       220 VP CLTEVENT       Engine RPM Input             EFI Data Interface    These V Net modules have been created to interface with many electronic fuel injection systems on the market  Each V Net  EFI Data Interface module is equipped to allow direct connection with EFI  These modules allow your V series data recorder to  share the data collected by these systems rather than having to install duplicate sensors to monitor functions that are already  being monitored by the EFI system  The shared data can be recorded or displayed just as you would any function monitored  independently by your Racepak V series recorder  Caution should be exercised to ensure that you do not exceed the maximum  number of V Net channels supported by your particular logger  The individual functions monitored by each EFI system are  outlined in the chart below     For use with Racepak V Net data loggers     Autronic SMC  amp  SM2 230 VM EFIAUT  Corvette C6 OBDII GMX3  2006 and later  230 VM EFIC6  Haltech 
112. s sensors  to provide the information  they display  while others  are stand alone requiring  no data recorder  When  you add Datalink Il  the best    V300SD DATA RECORDER        Terminator Cap  amp     Te          RW m wmmmmmmmmm  Four Available High Speed Analog Channels  V Net  These channels are usually reserved for monitoring functions Tee Connector   that require sample rates faster than 100 samples per second     DIGITAL  RPM   WIRING HARNESS             BLUE  START RECORDING BUTTON     RED  12V POWER SWITCH   jm LACK  ENGINE RPM   re ELLOW  CLUTCH RPM  IF USED   PG RAY  DRIVESHAFT RPM                                  Oil  Pressure  Module  amp  Sensor    Fuel  Pressure  Module  amp  Sensor       Tachometer Oil Pressure       Windows   based software in  the business  you will see why  Racepak continues to be the  most popular and widely used    Gauge  amp  Module Gauge  amp  Module    Intelli G auges EGT  Ultra Dashes Thermocouples   amp  Module    V Net Modules    data acquisition system in the  industry        In order for a function to be monitored on the V Net  the signal from that function must pass through two components  a sensor and  a module  The sensor is the unit that actually measures the input from the function  i e  pressure  temperature  etc    while the module  converts the signal so it can be transmitted over the V Net  To make it easy for you to select the proper components  Racepak offers  a variety of manners  as shown below  In the module sensor s
113. se Jih  mine jeu  sa    emen     os maa mw  noxius     use Dee ges uri    1504  A     AATLO2Z602RA L7  MPH           SImil wl wegl ve             IN                    GRAPHS  Clicking the channel buttons allow you to display a  single function  or as many functions at once as you desire  Graphs  can be expanded or compressed  or you can zoom in on any area  of interest  The zero point of the graph s timeline can be set by the  user  This allows the occurrence of any event to be measured from  a standard reference point     Report   Min Max Repon by L Travel P                     NUMERIC VALUES  When moving the vertical cursor on a graph  the numeric value of each monitored function  at the cursor s  position  will be displayed alongside its channel button  The time from the start of the run to the cursor s location is also shown     OVERLAY FILES  All Datalinkll programs have the ability to overlay the graphs from multiple files  This gives you the ability to visually  compare any recording against another  Evaluating the results of tuning changes or driving techniques becomes instantly obvious     CIRCLE TRACK AND ROAD RACE FEATURES  With the Pro software you can create a detailed track map of every circuit you  run from the information you generate  GPS will allow you to plot the exact position of the car as it travels around the track  You will  then be able to compare individual lap times within a recording session  or against laps from previously recorded sessions  You 
114. sed it is highly suggested that when purchasing or  selling a data recorder that the software be regarded as a component of that particular recorder  Keep the two together as a unit                 Replacement Software   Purchase of a V series recorder includes the data analysis software  However  should a replacement become necessary use the  part numbers shown below  It will be necessary for you to provide Racepak with a copy of an existing file so we may configure your  software to match your existing setup   Datalinkll Software Kits  includes CD disc  licensing disc  manual      Datalinkll File Viewer           oonoohhuuhhuhhuha 890 DL FV  Datalinkll Lite    ape ew eee EEN 890 DL LITE  Datalinkll Standard               ccn nuum 890 DL STD  Datalinkill Pro 4a  tree eee knee ii 890 DL PRO    Use these programs to upgrade from an existing Racepak Windows   based software program to the latest version of a higher level  of Datalinkll   Upgrade Datalinkll Lite to Datalinkll Standard     890 UG LITESTD  Upgrade Datalinkll Lite to Datalinkll Pro         890 UG LITEPRO  Upgrade Datalinkll Standard to Datalinkll Pro    890 UG STDPRO                 Ai    ne    i La  me      Pt    4     mo e i   NS p 4  A       owe       4 i    um ss M      LATA  LAB  EROE    In every form of motorsports  where engine performance  is critical  weather becomes an important factor  Knowing  the amount of oxygen that is available for making  horsepower  or knowing how much a change in the  weather wil
115. siii 220 VS 300GVT  O 500 Dsl ici  ERREUR RA ERROR ede ee 220 VS 500GVT  0 1500 psl sca AA See eee ae n 220 VS 1500SVT  Vacuum Pressure  30 In  hg 0 30 psi                   220 VS VB    To measure pressure functions using sensors seen on page 25     TEMPERATURE   Fluid Temperature   Temperature  0 300  F  Fluid type Sensor           220 VS TR 300  Uses the  810 TR 300 sensor seen on page 28     QUICK DISCONNECT TERMINAL KIT  Thee connector kits provide you with the components that will allow you to  shorten the pigtail cable between the V Net module and pressure sensor or a TR   type temperature sensors  Each kit includes enough components for one module   Fluid Temperature Sensors enn bk KR bb bb mp 810 CN TR2P  Use with V Net modules and temperature sensors having prefix number of 220 VP   TR   220 VM TR   or 230 VM TR    Pressure Sensors                 cron hhhhhhhrn 810 CN TISP  Use with V Net module and pressure sensor having prefix number of 220 VP PT    220 VS   or 230 VM PT      EXTENSION CABLES   These custom built extensions can be used to extend the length of cables that  use a 2 Pin or 3 Pin Molex connector to attach the sensor to the power harness or a  module   s pigtail  Please specify length required when ordering   2 Pin Molex Cable  Specify Length                   800 CA EXT2P  3 Pin Molex Cable  Specify Length                   800 CA EXT3P    MOLEX TERMINAL KITS   These connector kits can be used if the need arises to shorten a cable that is  terminate 
116. sor   Wire loom and connectors for sensor input  termination    Display Dash Provides View of   Any 21 sensor inputs connected to the dash  shift Light Output   Warning Lights    Dimensions    4     H  X 10 2     W  X  75    deep      Requires 2    rear clearance    10 16cm X 25 908cm X 1 905cm     Weight   21 ozs    58 kg     UDX Replay    www RACEPAK com           bh    120 Ki    S e  3 See 140    R 160   WATER  o F    200  gt   Na    Racepak   s Intelli Gauges are the best way to relay pertinent engine and  drivetrain information when using our V Net data recording systems   The V Net wiring capabilities means the gauges and the data acquisition  components can share the same sensors to reduce wiring     All of the gauges are 2 5 8    diameter and feature a 270   sweep needle  along with a programmable digital display  The gauges are available  with a black or white face and are easy to view thanks to electro   luminescent lighting  Page 17 shows all of the available gauges     INTELLI GAUGE DIMENSIONS       FEATURES    User Programmable warning levels  Download recorded data to PC  Plug and play installation   Analog and digital display  Lightweight  sonic welded  Electro luminescent radial lighting       GAUGES     949  709 5555          INTELLIGENT GAUGES  These are not your average  analog or digital gauge  They are both  In addition  they  are highly accurate  stylish  dependable  and provide  real time display for your monitored functions     WARNING ALARM  Intelli G
117. sors that connect to either the hardwired RPM or Analog input ports of V300SD  V500 or G2X Pro data recorders   Each Interface module provides the necessary signal conditioning for its attached sensor thereby allowing the sensors to communicate  with the Logger via a single cable    Interface modules do not require any programming  however you may only attach up to four Interface module together in series  The  four modules may be connected directly to each other  Daisy chained  or they may be linked with an Interface cable as illustrated below    The list below shows a selection of Interface modules that will help you in the task of connecting almost any type of digital or analog  sensor to a V300SD  V500 or G2X Pro recorder        RPM Analog  Port Port    Analog Interface Modules without Sensor  V300SD shown  OH      A Interface Modules    1 50 gt  jii gu DAI vg  hth HR       Dust Interface    Cap Cable Cable  1234  zm  Pressure Input  5 Volt                rrr rr 240 IM PT 5V  Pressure Input  12 Volt                 rrr rre 240 IM PT 12V  Temperature  Thermocouple Input  0 600PF         240 IM TC600  Temperature  Thermocouple Input  0 1800  F       240 IM TC1800  Position Travel Input bb bb bb KEE nr nnnm 240 IM TRAV  Shock Travel  Right Front  28    Pigtail  Std       240 IM TRAV28RF  Shock Travel  Right Front  38    Pigtail          240 IM TRAV38RF  Shock Travel  Left Front  65    Pigtail  Std         240 IM TRAV65LF  Shock Travel  Right Rear  48    Pigtail  Std        2
118. t system  The black Interface Tee cables and dust caps are used just for the purpose their names imply     They are not required for the system to operate properly     Bulkhead connectors are used when a V Net or Interface cable must pass through a firewall  body panel  or motor plate  They  provide a male female connector on each side of the panel  These are specific to the type of cable that is being used and are color    coded for easy identification           Tee Cable  9     Tee Cable  18     Tee Cable  36       280 CA VM T009  280 CA VM T018  280 CA VM T036    280 CA IM T009            Terminator Cap  Male    280 CA VM TCAPM       Terminator Cap  Female    280 CA VM TCAPF           Dust Cap  Male    280 CA IM DCAPM          Dust Cap  Female       Bulkhead Connector    280 CA VM BHEAD 280 CA IM BHEAD              280 CA IM DCAPF                     SENSORS    In the section that follows  you will find a selection of sensors that are applicable to every type of recording device  These sensors  will provide you with the means of expanding your system to record or display almost any function you wish  It is important to use  the appropriate type of signal conditioning module and cable for each application when applying any of these sensors to the various  recorder systems     Pressure Transducers   The small size and ruggedness of these    PT type    pressure transducers make them ideal for the measurement of pressure directly  at the source  The transducer requires 5 volt 
119. the SwitchPanel  reducing wiring clutter  Users needing  additional switch panel capabilities can easily expand through the use of a     Jumper    cable to a second Racepak SwitchPanel    The V Net compatibility insures a seamless integration with existing  Racepak data logger or displayed equipped vehicles  while also providing a  future upgrade path for additional inputs  control modules and instrumentation   when utilized as a standalone power control module    Each Racepak SmartWire Kit includes the module and connector kit        FEATURES    Capacity   125 total amps    Channels    30 total channel outputs     8 channels   20 amp maximum  22 channels   10 amp maximum    ISUYNOI  035019    12 hardwired switch inputs    Data Output   Volts   Amps   State    Response   3 0 millisecond    Programming   USB Interface    Dimensions   6     L  X 5 5     W  X 1 5     H    25 2 cm X 13 9 cm X 3 8 cm     Includes   Racepak SmartWire Module  Connector Kit        SmartWire  Switch Panel    SmartWire Module Kit                                500 KT SW30   SmartWire Switch Panel                              500 SW PNL8   SmartWire Switch Module                            500 SW 5MI6   Switch Panel Mount Brackets                         500 MB SPxxxx  Available sizes are  1 50   1 625    and 1 75      SmartWire to Switch Panel Cable                      580 CA BN5P xxx  Variety of sizes offered    SmartWire to V Net Cable                   e nnn nnm 280 CA BN5P xxx  Available sizes are
120. the dash  When the vehicle is stationary the gear indicator becomes a display  of the number of satellite currently being monitored  The dash is also used to  provide a means of defining the start finish line while on the track  thus providing  immediate access to displayed data  The dash can be attached to a steering  wheel or mounted on the dash panel  A single cable provides the connection  between the G2X and the dash for programming purposes     G2X Data Recorder Kit     00000n enue 600 KT G2XR  Kit without Dash      000ne eee 600 KT G2XRND    Go A    Includes logger mounting plate  black anodized billet aluminum clamp bracket    G2X 1 250    dia tube                  cee nn nh n mmm nn 610 MB 125  G2X 1 500    dia tube sous xa RR ERR Rn RE ns 610 MB 150  G2X 1 625    dia tube                   ee nn rn n n nm nn 610 MB 1625  G2X 1 750  dia TI TEE 610 MB 175  Typical Uses  The G2X GPS package monitors    Road racing Lap Times   Oval Track racing Lap Number   Club racing Per Lap Gain Loss   Driving schools Gear Indicator   Karting Progressive Shift Lights   Pulling Accel G Lateral G   Motorcycles Battery Voltage   Test facilities GPS Speed                             FEATURES       Channels   V Net  12  Internal  4  16 Total Channels    Sample Rates   V Net  up to 100 per second    Memory   Up to 16GB SD Memory Caard   Recording time depends on number of channels  monitored and sample rates   Record multiple runs   Cableless download    Internal Sensors   Battery Voltage 
121. ting Brackets  Hagai  for 1 750    O D  tubing                        800 MB V500 175  Typical Uses  The G2X Pro package monitors  The G2X Pro package includes   Road racing Accel G G2X Pro Recorder  Oval track racing Lateral G GPS Antenna  Boats Battery Volt Up to 16GB SD Memory Card  Motorcycles Track Mapping Datalink Il Software  Pulling GPS Speed Communication Cable  Lap Time Power Ground Engine RPM Harness  Lap Number  segment Time    Engine RPM     949  709 5555        DATA RECORDERS    CLOSED  COURSE    DATA RECORDER             sgy rs    vs ars GPS  MaoTORSPDP Faustian  TA ACQ     pak  Lair chase or            gt  ru  COM   TV INTSDIGINITIO i            The key to the G2X is its ability to interpret signals from GPS satellites to  quickly establish the position and movement of the vehicle  From this monitored  data other performance parameters can then be calculated  The G2X has the  ability to provide track mapping  lap times number distance  segment times   speed  lateral G force  and acceleration G force  With 128 MB of memory  over  20 hours of GPS data can be stored    Enhancing the features of the G2X is its versatile digital display dash that will  provide the driver with a display of lap times  lap number  per lap gain loss   gear indicator  progressive shift light  battery voltage  and G forces  Engine  RPM is available to those with an ignition system that provides a tach signal  output  and three additional inputs from external sensors can be displayed on  
122. ule  see page 26                      240 IM TRAV       For connection to Analog port of V300 or V500 recorders  Strin      Potentiometer             Wheelie Bar Load Cell    Savvy drag racers monitor the pressure exerted against their wheelie bars when  they are in contact with the ground as a method of evaluating their chassis set up   By incorporating these load cells into each of their wheelie bars  a record of how  long and how hard the car was on the wheelie bars  and whether both sides register  equal loading pressure  gives a visual record of how the car is reacting to the set up    Monitoring and graphing the pressures generated in these load cells is  accomplished by attaching a V Net module and pressure sensor to each load cell   Pre programmed modules and sensors are shown below     WHEELIE BAR PRESSURE SENSORS    V Net Module  amp  Sensor  Wheelie Bar Pressure  Load cell not included     Left  0 3000 psi                  nnn n nr 220 VP PT WBL3K  Right  0 3000 psi    waaa BARA EIERE E RES WA 220 VP PT WBR3K  Wheelie Bar Load Cell  Single                   800 SN WBLOAD    Ride Height Sensor    Infrared sensors are used to monitor the distance to an object  relative to the sensor   when contact cannot be made with the object  This makes them ideal for use in  setting up the suspension by monitoring chassis ride height in relation to the moving  ground plane  Infrared Ride Height sensors and modules are commonly attached to  the V Net cable of any V series recorder
123. us Fuel  2  0 15 psi ww  eee 220 VP PT NF215  Nitrous Fuel  3  0 15 psi               rr rrr 220 VP PT NF315  Nitrous Fuel  4  0 15 psi               rr rrr 220 VP PT NF415  Oil  0 150 psi   iecur enr ERE EE RR ERR x  220 VP PT OP150  Oil  0 300 psi ww wee 220 VP PT OP300  Pressure Differential  0 40    H O to 15 psi        220 VP PT PD145  Transmission  0 300 psi                  e 220 VP PT TP300  Turbo Back Pressure  1  0 75 psi               220 VP PT EP175  Turbo Back Pressure  2  0 75 psi               220 VP PT EP275  Turbocharger Outlet 71  0 75 psi                220 VP PT TB10  Wheelie Bar  Left  0 3000 psi                  220 VP PT WBL3K  Wheelie Bar  Right  0 3000 psi                 220 VP PT WBR3K  VACUUM  Manifold  30 psi 0 30 In  hg                      220 VP PT BVAC  Pan  Crankcase   0 30 In  hg                   220 VP PT PVAC  TEMPERATURE    Note  pigtail cable lengths are shown in parenthesis     Cylinder Head  Left  0 600  F   36                220 VP TC HEADL  Cylinder Head  Right  0 600  F   367              220 VP TC HEADR  Engine Oil  0 300  F   48             rrr rm ann mp 220 VP TR OIL  Intake Manifold  Open Tip  0 600  F   36          220 VP TC MANIF  Intercooler Inlet  0 300  F   72                      220 VP TR ICTI  Rear End Oil  0 300  F   72     seen ab kk ERR ahh o 220 VP TR RET  Transmission Oil  0 300  F   72      ee eeh bb bb bp 220 VP TR TRANS  Water  0 300  F   72             rrr nn m nm mRRR 220 VP TR WATER    Fluid Temp 0   300  F  
124. using our V Net data recording systems   The V Net wiring capabilities means the gauges and the data acquisition  components can share the same sensors to reduce wiring     EASY INSTALLATION  If a function is currently being  monitored on the V Net  simply plug the gauge online  and it shares the signals from that function s sensor   If not  install a sensor and its module for the function  you wish to monitor  plug both modules onto the V Net    All of the gauges are 2 5 8  diameter and feature a 270  sweep needle cable  and the installation is complete     along with a programmable digital display  The gauges are available  zh a black or white face and are easy to EES thanks to electro  ENGINEERED FOR LOOKS AND PERFORMANCE   luminescent lighting  Page 17 shows all of the available gauges  When you combine the looks and performance of  these gauges you have an unbeatable combination  INTELLI GAUGE DIMENSIONS of elegance and function  Intelli Gauge cases and  connectors are sonic welded to provide maximum  protection against contaminating elements  They weigh  a mere 49 grams  Their smart looks can be attributed  to an easy to read dial face that uses wide spread  increment marks in the prime operating range  a digital  display to complement the needle movement  and a  smooth curved bezel that surrounds your choice of a  white of black dial face   ELIMINATE THE CLUTTER  Using the Intelli Gauge  with one of our data acquisition systems is a great  FEATURES way to eliminate som
125. wing  Metric and English capable    103 Logger       Base Logger Dash Downloaded Data Provides     GPS Speed   Lap Times  Segment Times  Track Mapping  Battery Voltage  Accel G   Lateral G  Vertical G   Data Reports  Engine RPM  Full data analysis with data export and math channel capabilities    www RACEPAK com       Nang    Fe f  wOr                c  fe  OOS Bee        P    The G2X Pro builds on the G2X s already impressive capabilities by allowing  the user to monitor up to 71 channels  while providing lap and segment  timing along with speed and track mapping functions through the use of GPS  information  The G2X Pro utilizes our exclusive V Net plug and play technology  which allows the data from up to 55 sensors to be transmitted via a single cable  to the data recorder  The G2X Pro brings with it more hardware in the form  of our steering position  throttle position  and brake pressure package  This  package provides easy installation through the use of a module that permits  the user to terminate these sensor cables to the desired length  A single cable  then links the module to the G2X Pro recorder  Suspension and ride height data  may also be obtained by purchasing the appropriate shock and ride height  sensor package  which installs and transmits data in the same method as the  steering throttle brake package  In addition  any V Net sensor may be used  with the G2X Pro              DATA RECORDERS    FEATURES    Channels    72 Total   V Net  56   Analog  8 hard wir
126. y must operate     Transducer  A device that converts a physical property  such as pressure or position  into a voltage signal that  the data recorder can understand  Used on temperature  pressure  vacuum  or movement signals     Transducer Box  A rectangular box that houses up to four hard wired  strain type pressure transducers or  signal conditioning modules  Commonly used as a junction box for pressure lines which are then connected  to the V Net cable with a single module     Upload  The process of transferring information from a data recorder or data cartridge directly to a laptop or  desktop computer     USB Port  The type of communication port used on newer model computers to connect peripheral equipment  such as amouse or printer  The Racepak data cartridge uploads recorded information into the newer computers  through the USB port     V Net  An exclusive Racepak system that allows the input or output of information from many sources over  a single cable  V Net greatly reduces the need for wiring  while increasing the capabilities of the system   V Net allows multiple components  gauges  data recorder  controller motors  etc   to share the signals being  transmitted over the V Net cable     Windows    Is a registered trademark name of the Microsoft Corporation  The term has become generic when  referring to the most common method of navigating your way around a computer program  It uses point and   click on icons  rather than the need for written commands as used wit
127. ypically used to monitor manifold or pan vacuum  A vacuum line is routed directly to transducer   Thermocouple Amplifier Module  0 500  F           810 M TC2 500    Cable Only  Thermocouple   Sensor to Module  over 3         800 CA TCEXT XL  specify length   Cable Only  Thermocouple   Sensor to Module  under 3          800 CA TCEXT XX  specify length    Used on low temp applications such as water  oil  cylinder head  Not for use with EGTs  Module   cable and sensor kit available as PN  810 KT TC 500  Specify use and cable length  See sensors  only on page 30    0 5 Volt Input Module    can output either 5 or 12 volts to powered sensor 810 MD 0 5V2   Cable Only  Sensor to module 800 CA 3PM  specify length     Receives 0 5 volt input from powered sensor while providing 5 or 12v to power the sensor        Pro Analog  Transducer Box Il       Pressure Transducer             GOODFVEAR Ca Ka    DET asma diddl       Pro Analog Transducer Box  Old Style     The Pro Analog Transducer Box offers an additional method of connecting analog  sensors into the V Net recorders  Each Pro Analog Box will house up to four of the plug   In style transducer modules  The box is the connected to either the V Net cable or the  analog port  via a single cable  by using one of the appropriate adapter modules shown  below  Plug in style transducers and adapter modules must be purchased separately     ADAPTER MODULES   VNO 212264 RAE rh AG AA 230 VM 4ANA8  Adapts 8 Pin Pro Analog Box to V Net cable    Int
    
Download Pdf Manuals
 
 
    