IQRF RangR User`s Manual

image

Contents

1. ndicate DPA Device and observe your module for a flashing light WWW IQHOME ORG 2015 PAGE 14 RANGE TESTER USER S MANUAL 3 5 2 SETTING CHANNEL 1 Connect to one of the tester modules according to chapter 3 5 1 2 Click on Configure TR button 3 When the TR Configuration windows appears go to the HWP page CAUTION Do NOT make any changes on OS page or to other values on HWP page than instructed Misconfiguring values can lead to device fault and loosing access to the device File Ll DPA version 05 HWP Description Standard Peripherals RF EEPROM 120 EEEPROM THERMOMETER RAM C PWM LEDR UART LEDG FRC _ SPI RX filter 5 Alternative DSM channel Available at Demo version and Node device only Custom DPA Handler 10 Setup Autoexec DPA interface Routing off DPA Interface UART interface baud rate 57600 Bd Allow peer to peer To set up transmission channel set the desired value in RF channel 2nd network field 5 When you configured the desired values click on Upload button If no error message appears the configuration is successfully uploaded 6 Repeat steps 1 5 on the other module of the tester pair CAUTION Always use the same values in both modules If you misconfigure RF network tester modules will not hear each other 7 The transmitting channel is
2. now the desired Press Disconnect in the DPA Service Window PAGE 10 14 2015 WWW IQHOME ORG USER S MANUAL RANGE TESTER 3 5 3 SETTING TRANSMIT POWER 1 Connect to one of the tester modules according to chapter 3 5 1 Click on Configure TR button 3 When the TR Configuration windows appears go to the HWP page CAUTION Do NOT make any changes on OS page or to other values on HWP page than instructed Misconfiguring values can lead to device fault and loosing access to the device EEPROM RMOMETER RX filter 5 RAM 7 LEDR LP RX timeout 1 Z LEDG SPI avr T RF channel 2nd network 42 Alternative DSM channel 0 Available at Demo version and Node device only DPA Interface Custom DPA Handler IO Setup Autoexec Routing off Allow peer to peer UART interface baud rate 57600 Bd Node DPA interface To set up transmission power set the desired value in TX power field 5 When you configured the desired values click on Upload button If no error message appears the configuration is successfully uploaded 6 Repeat steps 1 5 on the other module of the tester pair 7 The transmitting power is now the desired Press Disconnect in the DPA Service Window WWW IQHOME ORG 2015 PAGE 11 14 RANGE TESTER USER S MANUAL 3 5 4 SETTING MINIMAL SIGNAL THRESHOLD 1 Connect to one of the tester modules according to chapter 3 5 1 Click on
3. the circuit board from the box remove the old battery insert the new same type battery put back the circuit board by first positioning back the tact button to it s hole reseat the back plate p ue e ie insert the 4 screws and tight them WWW IQHOME ORG 2015 PAGE 7 14 RANGE TESTER 3 5 CONFIGURATION For the best approach of the final working environment the tester pair has some basic configuration options For changing these settings the user needs IQRF IDE with CATS service tools configured with a wireless programmer USER S MANUAL Of course the tester pair comes with factory default configuration what can be used out of the box 3 5 1 CONNECT TO THE TESTER MODULE 1 On your PC connect your CATS compatible IQRF programmer with a proper DC TR module inserted lunch IQRF IDE and start CATS service tools Tools gt CATS Service Tools gt CATS Control 2 Inthe CATS Service Tools Control window you should see that CATS status is connected If not fix it by connecting a programmer with an IQRF module with CATS installed or choose Create CATS Remove CATS CATS Tools CATS Service Tools Control 25 DPA Service 4 x Create CATS CATS Info Status connected RF band 868 MHz CATS version 1 02 DPA Service Parameters RX sensitivity power 7 High Default Programmer Parameters e DPA Service RF band RF channel
4. A RF channel B TX power Packet repeats RF Programmer 868 MHz 22 2 1 A hu eS k 4 Enabled Silent mode LP mode Default 3 Switch to the DPA Service page leave the defaults and click on the Connect button CATS Service Tools 58 Control DPA Service Authorization DSM RFPGM Backup Device Info PAGE 8 14 0000 USEC Set MID First available Disconnect Scan MID Unbond Restore Bond Clone 2015 Configure TR Indicate DPA Device WWW IQHOME ORG USER S MANUAL RANGE TESTER 4 Whena DPA Connecting windows appears switch on one of the tester modules or power cycle if it was powered on DPA Connecting DPA service mode MID First available 5 When successfully connected to the tester module the Device Info area will show the current information about the device CATS Service Tools A Device Info USECH FFFF MID First available Connect DSM uten Scan MID Bond Configure TR Indicate DPA Device DPA version 2 13 STD DPA interface SPI Custom DPA Handler detected Yes TR Module Type DCTR 52Dx MCU Type 16171938 T MID 81001941 x 05 Version 3 06D OS Build 0707 RSSI 55 z Supply Voltage ENN 1 107 6 Toensure that you made the right connection use
5. Configure TR button 3 When the TR Configuration windows appears go to the HWP page CAUTION Do NOT make any changes on OS page or to other values on HWP page than instructed Misconfiguring values can lead to device fault and loosing access to the device EEPROM EEEPROM RAM J LEDR RX timeout 1 4 LEDG SPI RF channel 2nd network 42 Alternative DSM channel 0 Available at Demo version and Node device only DPA Interface Custom DPA Handler IO Setup Autoexec Routing off Allow peer to peer UART interface baud rate 57600 Bd Node DPA interface To set up minimum signal threshold set the desired value in RX filter field 5 When you configured the desired values click on Upload button If no error message appears the configuration is successfully uploaded 6 Repeat steps 1 5 on the other module of the tester pair 7 The transmitting power is now the desired Press Disconnect in the DPA Service Window PAGE 12 14 2015 WWW IQHOME ORG USER S MANUAL RANGE TESTER 4 APPENDIX 4 1 TROUBLESHOOTING No lights on the display The unit is turned off Power on the unit The battery discharged Replace the battery Only the smallest signal The other module turned off Turn on the other module too indicator lights up Cannot hear the other Try to reposition the modules module closer to each other The replace battery icon Battery needs to be re
6. iQ RANGE TESTER USER S MANUAL EN EU 2015 RANGE TESTER USER S MANUAL CONTENTS 2 1 PS AU 3 1 1 yO S 3 2 5 2 1 872 Eel an d eee nee 5 2 2 ______________________ ___ 6 3 7 3 1 7 3 2 aia dol P RE ______6_ __ __ 7 3 3 p wer OFF 7 3 4 7 3 5 0 eee ___ _______ ______ 8 3 5 1 Connect to the tester module 8 3 5 2 EET 10 3 5 3 DOW ____ 11 3 5 4 Setting minimal signal thresoltlciuaseeosespe seb e eer vpn Up TuS 12 4 ava eI E EE A X X 13 4 1 RIT 13 4 2 ene TE 14 USER S MANUAL RANGE TESTER 1 PREAMBLE 1 1 FOR YOUR SAFETY To prevent damage to your product or injury to yourself or to others read the following safety precautions before using this equipment Keep these safety instructions where all those who use the product will read them WARNINGS Turn off immediately in the event of malfunction Should you notice smoke or an unusual smell coming from the e
7. le s battery gets exhausted the replace battery icon will light up in red color PAGE 6 14 2015 WWW IQHOME ORG USER S MANUAL RANGE TESTER 3 USING THE PRODUCT 3 1 SWITCHING ON AND OFF The device has a power switch to turn on and of it To turn ON switch to the I position push in the upper side next to the tact switch To turn OFF switch to the 0 position push in the lower side 3 2 READING THE DISPLAY When the tester is turned on the first RED level indicator is illuminated If the module receives radio signal and data packets from the other module the other indicator bars also gets illuminated depending on the signal strength The meaning of the bars can be found in chapter 2 2 3 3 AUTO POWER OFF FEATURE To conserver battery power the device will go to sleep mode after 10 minutes of inactivity To wake up simply push the Lower Tx power button the tact switch next to the power switch or power cycle the unit power off then power on 3 4 REPLACING THE BATTERY If the replace battery light appears or light appears after switching on you should replace the tester unit s battery CAUTION Do NOT use standard 1 5V AA size alkaline battery Always use the same type lithium battery what used previously Recommended battery type ER14505 AA size 3 6V To replace the battery switch off the power button remove the 4 screws from the back plate remove the back plate lift
8. placed Replace the battery illuminated in red color The signal level indicator The Lower Tx power button This is a normal operation flashing continuously pressed on any of the two Release the button to stop modules flashing The module is powered on Auto power off feature disabled Pres the Lower Tx power button but no lights on it the lights to wake up the module or Power cycle the module Battery discharged Replace the battery Modules indicating different Asymmetric module If this is not the desired state levels configuration reconfigure modules with the same RX filter and TX power values Battery power is low Replace batteries WWW IQHOME ORG 2015 PAGE 13 14 RANGE TESTER USER S MANUAL 4 2 TECHNICAL DATA ramet Physical dimensions 90mm x 64mm x 32mm without mounting 106mm x 64mm x 32mm with mounting Power supply DC 3 6V Lithium battery Battery type ER14505 Operating frequency 868MHz PAGE 14 14 2015 WWW IQHOME ORG
9. quipment power off the equipment and remove the battery immediately taking care to avoid burns Continued operation could result in injury Do not use in the presence of flammable gas Do not use electronic equipment in the presence of flammable gas as this could result in explosion or fire Keep out of reach of children Failure to observe this precaution could result in injury Observe proper precautions when handling batteries Batteries may leak or explode if improperly handled Observe the following precautions when handling batteries for use in this product e Use only batteries approved for use in this equipment Do not short or disassemble the battery Be sure the product is off before replacing the battery Do not attempt to insert the battery upside down or backwards Do not expose the battery to flame or to excessive heat Do not immerse in or expose to water Do not transport or store the battery with metal objects such as necklaces or hairpins e Batteries are prone to leakage when fully discharged To avoid damage to the product be sure to remove the battery when no charge remains When the battery is not in use store in a cool dry place The battery may be hot immediately after use or when the product has been used on battery power for an extended period Before removing the battery turn the device off and allow the battery to cool e Discontinue use immediately should you notice any changes in the ba
10. ste For more information contact the retailer or the local authorities in charge of waste management WWW IQHOME ORG USER S MANUAL RANGE TESTER 2 OVERVIEW 2 1 PHYSICAL OVERVIEW The range tester appliance has two nodes configured to each other For any testing you need to operate both of them with the sane software configuration Each module has the following main parts Signal level indicator Battery exhausted indicator replace battery Power switch Lower transmit signal power Wake up button Battery holder inside ue a 112 m aa emi Ri R2 Ci Bp 2 RS IC 14 gt WWW IQHOME ORG 2015 PAGE 5 14 RANGE TESTER USER S MANUAL 2 2 FUNCTIONS The product s main function is to display how strong signal arrive form the other tester module The display s meaning is the following Unit powered on no signal or signal below minimum level below RX filter RSSI gt RX filter 5 37 absolute RSSI gt RX filter 12 17 54 absolute RSSI gt RX filter 24 29 61 absolute When a stable signal found you should press the Lower Tx signal power button At this time the device will transmit on a decreased power and the signal level indicator start flashing and displays the actual signal strength If you release the button the indicator stops flashing and the configured Tx power is restored When the tester modu
11. ttery such as discoloration or deformation Failure to observe this precaution could result in injury WWW IQHOME ORG 2015 PAGE 3 14 RANGE TESTER NOTICES USER S MANUAL e This manual included with the product may not be reproduced translated to any language or used to any other purpose without IQ Home s written permission Q Home reserves the right to change specifications described in this manual at any time without prior notice Q Home will not be held liable for any damages resulted from the use of this product e Wemade as much effort as we could while prepared this manual to make it useful accurate and complete If we made mistakes we appreciate if you contact us and let us know CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS This symbol indicates that this product is to be collected separately This product is designated for separate collection at an appropriate collection point Do not dispose of as household waste e For more information contact the retailer or the local authorities in charge of waste management PAGE 4 14 This symbol on the battery indicates that the battery is to be collected separately 2015 All batteries whether marked with this symbol or not are designated for separate collection at an appropriate collection point Do not dispose of as household wa

Download Pdf Manuals