Home
AcNetPro_ Manual
Contents
1. Plug the converter into an available USB port on your computer Ascreen will appear telling you that there is a new device plugged into the USB bus Click on the Next gt button New screen will appear Make sure Search for the best driver for your device is selected Then select the Next gt button New screen will appear Make sure CD drive is selected Insert the attached CD into the CD Drive Then select the Next gt button New screen will appear Make sure FTDI Converter is listed as the device Then select the Next gt button The screen above will appear Click the Finish button to complete the installation The AcNetPro Installation Manual 7 Dipswitch Setting The dip switches allow the module to be configured for two wire or four wire RS 422 or RS 485 modes In two wire mode the TD and RD are tied together and so are TD and RD sW1 SW2 SW3 MODE Description Tx or Rx Half Duplex on an om RS 485 2 Wires Tx always Enable Rx Enable only while transmission off ON OFF ON RS 422 4 Wires Echo off Tx Enable only during transmission Rx always Enable ope PWN OFE RS 422 4 Wires OFF OFF ON Tx always Enable Rx always Enable RS 422 4 Wires Echo on 8 General Specification e Standard EIA RS 485 Ports 1 x RS485 1 x USB e Max Distance 1200 m e Data Rates 300 Baud up to 115k bps e Isolation None
2. LED s Red Led Tx indicator Green Led Rx Indicator e Power from USB e Compatibility USB 1 1 standard e Input USB protocol e Output RS 422 485 protocol e Cable USB type A connector Type A to Type B cable provided RS 422 Signal RX RX TX TX RS 485 Signals DATA DATA Self Tuner inside support multiple Baud Rate and multiple Data Format Mounting wall mounting Temperature Operating 0 C to 50 C Storage 20 C to 60 C Humidity Operating 10 to 80 non condensing Storage 5 to 90 non condensing Dimensions 95 mm x 65 mm x 37 mm Driver supported Windows 98 ME 2000 XP The AcNetPro Installation Manual 18 8 2 The DS100 TCP IP RS232 Device Server General Description The DS100 is a TCP IP to RS232 Device Server It allows to connect ACTEC controllers to an Ethernet 10 BaseT TCP IP network How to configure the DS100 through the LAN Connect the DS100 to Power with a 9VDC power jack The inside Connect the DS100 to the LAN via RJ 45 cable Install from the delivered CD the Tibbo Device Server Toolkit on your PC Go to Start Programs Tibbo Tibbo Device Server Manager The program should auto detect the DS100 Its initial IP address is 127 0 0 1 Click on the IP address and then on lt Change IP gt and set the IP according to your LAN settings Consult your network administrator before setting the IP address Click on lt
3. IMPORTANT NOTICE All information and data contained in this document is proprietary and confidential CROW Electronic Engineering Ltd shall not be liable in any event for any claims for damages or any other remedy in any jurisdiction whatsoever whether in an action in contract tort including negligence and strict liability or any other theory of liability whether in law or equity including without limitation claims for damages or any other remedy in whatever jurisdiction and shall not assume responsibility for patent infringements or other rights to third parties arising out of or in connection with this document Further CROW Electronic Engineering Ltd reserves the right to revise this publication and to make changes to its content at any time without obligation to notify any person or entity of such revision changes These materials are copyrighted and any unauthorized use of these materials may violate copyright trademark and other laws Therefore no part of this publication may be reproduced photocopied stored on a retrieval system or transmitted without the express written consent of CROW Electronic Engineering Ltd Any new issue of this document invalidates previous issues CROW Electronic Engineering Ltd 2005 2006 All rights reserved Information in this document is subject to change without notice No part of this document may be reproduced or transmitted in any form or by any means electronic or mechanical without e
4. Pin 2 Receive Tx RS485 port Jumpers JP2 Connect the controllers as follows Port COM on i Connect the cable shield only at the _ 8s 232 RS 485 interface RS 232 RS 485 Tx Interface ya O fov G SSS EAN RS485 L Connect the interface to a good earth RS485 bus 1 2 Km Shielded twisted pair cable 22 24 AWG 8 1 gt 8 10n S 10n 98 Ton TX H 2 off Tx H 2off TxX H_ 2off TX H 2off 3 off 3 off 3 off 3 off a 4off l 4 off 4 off L 4 off DS1 5off i DS1 5off H DS1 5off DS1 5 off JP2 JP2 JP2 JP2 6 6 6 6 7 7 7 7 ACNETPRO 8 ACNETPRO amp 8 ACNETPRO 8 ACNETPRO amp The AcNetPro Installation Manual NOTES Do not connect the communication cable screen at any point other than at the RS232 RS485 interface end It is imperative that the interface has a good earth ground through the mains The importance of a good earth ground cannot be overemphasized Performance of the protection is directly related to the efficiency of the grounding system Each ACNET board must have its own address selected by jumpers DS1 1 5 as shown on page 13 Protection against RFI interferences Most of the interference will come by induction to the cable shield on which high and very high voltage may appear because of RFI interferences or lightning bolts To prevent perturbations the following rules must then be respected 1 Use a shielded 22AWG triple wire cable Receive Transmit Ov for the RS232 connection and
5. DS Settings gt In Network settings tab set Routing Mode Slave Device server IP XXX XXX XXX XXX lt Port Number gt By default the port number is 1001 It can be changed to another number e g 10001 Transport protocol TCP In Serial Properties tab set Serial interface RS232 Baud rate 4800 bps or other according to the specific controller Parity None Flow control None Click OK to exit the Properties screen Click OK to exit the Device Server Manager The AcNetPro Installation Manual 8 3 RS485 to RS232 TTL TCP IP MINI Interface The RS232 RS485 Mini interface is adapted for the Crow AcNetPro DBL which includes two controllers it allows to connect together these two controllers via their RS485 port to either a RS232 or a TTL or a TCP IP network Warning The RS485 side of this Mini interface does not include lightning protections LD 2 l J l 8 Rx Tx RX LTX H i 8 RS 485 Port 8 RX LTX OC fm xin cj J1 S RJ 45 AcNetPro Board 2 S l I RS232 TCP IP bridge i SW TIL i i j AcNetPro Board 1 LD 1 BI 1200 A l I AcNetPro DBL housing l Oi te l LD1 is a green led lit when power is on LD2isa bicolor led which shows the communication status of the RS232 line Green flashes when reception on Rx line Red flashes when transmission on Tx line SW1 selected the electric levels at the RS232 TT
6. on the wall or the dedicated emplacement and pay attention to the following points A Easy access to the unit B Effective Ventilation to the unit C Clear Electromagnetic Environment see 1 3 Set the kind of communication used see par 7 Set the controller address through jumper DS1 see par 7 3 On installation where several AcNetPro boards are used avoid using the same address for different boards Connect the card reader as explained on par 4 and pay attention to the following points A Select the technology used through jumper DS1 B For Wiegand technology install jumpers JP3 and JP4 C Power the card readers according to its consumption see its technical manual Connect the electric door opener using 20 AWG wires as explained on par 6 Pay attention to the following points A When using a DC voltage to an electric door opener installed a diode ON THE LOCK ITSELF B When a Fail safe opener is used C Connect the opener between the CO and NC relays outputs Connect the different detectors between the corresponding inputs 11 to 111 and the Ov as explained in par 5 The detector operating mode NO or NC time zones etc is defined by software see User manual of the corresponding application Connect an effective ground to the dedicated lag located at the protective ground pin in the controller housing Use a proper tool to fix the ground wire into the lag or solder it Connect the mains 230v Use a
7. use a shielded 22 AWG twisted pair cable for the RS485 connection A good quality cable shield must be used and the shield must be connected to a strong earth The shield should be from copper rather than aluminium since the latter provides only partial attenuation All communication cable shieldings should be connected to only one extremity and not both in order to avoid the problem of ground loops Whereas the connection for the RS485 wire shield should be carried out at the level of the concentrator and the connection for the RS232 wire shield should be carried out at the level of the terminal A distance of at least 50 cm must separate all such connecting cables from high tension cables from cables connected to an electrical power box controlled by the system or from any cables capable of generating strong interference such as cables connected to high power motors generators wireless telephone etc Since it is often located besides a variety of cables the external telephone line can also be a source of strong interference Extremely high tension produced by lightning bolts can enter the terminals through these above lines Such tension can reach the level of hundreds of thousands of volts It is therefore advised to use the ACTEC SP200 protection unit at the AcNetPro level This protection is included in the RS232 RS485 interface The AcNetPro Installation Manual 12 7 3 Setting the controller address In order to program
8. 17 6 Installation of the driver for WINGOWS ccccccccssccccesscesscessseusseesseesseesseesecesseesseesseessaeusaeesonseaeevaees 17 7 Dipswitch Setting sicacccicisccccsecesccccsesescsstacencesesaseceseccsereesastactesececasieitazceseceseseestsevesescnenanstsadtcesenaterstars 18 8 General Specifications lt cicscscceccceescccscessnscceseesviecscceccetesectncusscnteteacsrctnsstnectcaedsecatncsendeaesetsutecnececeeatery 18 8 2 The DS100 TCP IP RS232 Device Server cccccceccccccccessceceeueesaeueeceevaeueeeeevanuatserastvssssses 19 il General Description sccsisesasecssssceesccsaannevacesadissaacsnssnseenssndnensutnecov ce navaastussasaeeetuavahvasntieveciaxcaanscannaentaned 19 2 How to configure the DS100 through the LAN s ssssssssssrsresunsnnnnunnunnnnnunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnna 19 8 3 The R5485 to RS232 TT LITO PHI Ph neniun i E E teins 20 APPENDIX A THE 10 COMMANDMENTS OF THE INSTALLER ssssssssssrssunsnnnnsnnunnnnnnnnnnnnnnnnnnnnnunnnnnnnnnnnnnnnnnnnnna 21 HOW TO CON TACT US o ccs cic tincwcnnehtnectaneecsccnoataku tacky cledletecaasnadue cedenependumnl AE 23 The AcNetPro Installation Manual 1 1 1 1 2 INTRODUCTION The AcNetPro controller The AcNetPro controller is a microprocessor electronic board dedicated to applications such as access control alarm monitoring building management etc Many different applications can be run on the AcNetPro board according the the ROM and the firmwar
9. 4mm wide strip to attach the mains cable to the proper fixation located on the upper left corner near the main grounding stud inside the controller housing Conect the battery pack 12V 7Ah max using 20 AWG wires as explained in par 3 Programme the system if required as described on the User Manual of the application used The AcNetPro Installation Manual 2 THE ELECTRONIC BOARD AND THE PCB JUMPERS R4nc R3nc R2nc Rinc Tx H R4c R4no R3c R3no R2c R2noR1c Rino Ov Rx L 11111019 Ov 18 17 16 15 Ov 14 13 12 I Ov 292229 GSSESS GEE DOOLIO CEGEESCS f J4 J 6b p3 16a 232 J O J5b J5a 7 moi geese eeee soe Led 11 Led 1 O Alarm Input indicators Off if input closed wy Clk 1 114 Dat 1 115 Led 1 Led 2 Lon1 Buz 1 RL 4 RL3RL2 RL 1 S8r SY JOAUG fe Ov Vcc Clk 2 112 Dat2 113 Led 4 Led 5 Lon 2 Buz 2 BC 4100 Rev B CPU Lithium Cell JP 1 Eprom C Flash Reset g N 99999999 CSCS Fig 2 The AcNetPro Electronic board DS1 Board Address and Reader Technology J5 4 relays AcNetPro Dav 1A DS1 1 to 5 Board Address J7 Power 10Vdc to 13Vdc 0 5 A AcNetPro2 3 DS1 1 to 5 Board Address J1 Reader 1 J6 11 Alarm Inputs DS1 6 7 8 Reader Technology 6 on Wiegand Up to 50 bits with parity check 7 on Wiegand Up to 50 bits without parity check 8 on Not in use J2 Reader 2 JP1 Lithium Cell on off a JP2 Selectio
10. L port SW1 RS232 Rx Tx 12Vdc SW1 TTL Rx Tx 5v Ov The board needs a 8 12Vdc power and its consumption is 40mA max or 250mA when using the TCP IP bridge The Mini interface may be used in three different configurations Connector AcNetPro DBL to RS232 port SW1 AcNetPro DBL to TTL port AcNetPro DBL to TCP IP J1 on RS232 SW1 TTL SW1 TTL Tx To a PC To other devices us RS232 levels TTL Levels Housed sae not T Ov L To Rx L input of AcN boards To Rx L input of AcN boards To Rx L input of AcN boards H To Tx H input of AcN boards To Tx H input of AcN boards To Tx H input of AcN boards Vcc 5 Volts OUTPUT 200mA 5 Volts OUTPUT 200mA 5 Volts OUTPUT 200mA Ov Ov Power Ov Power Ov Power 12V 8 12Vdc power 8 12Vdc power 8 12Vdc power NOTE 1 To connect the mini interface to a TCP IP network insert a 10 Base T TCP IP bridge on the J2 connector The network has to be connected to the RJ45 of the TCP IP interface NOTE 2 Any controller can be use insted of the AcNetPro controllers The AcNetPro Installation Manual 20 APPENDIX A THE 10 COMMANDMENTS OF THE INSTALLER a 10 cm Separate Power Supply RS 232 RS 485 Interface Last Controller Controller Controller 10 Never pass the door opener cable near the other cables it must be at least 10cm from all other cables Use always a diode if the door opener is DC powered If the door opener consu
11. anual Introduction The CR40485 is a USB Universal Serial Bus port to 2 or 4 wire RS 485 422 converter That can be set up for an RS 422 or RS 485 network A pair of LEDs shows when RS 485 422 data is being received or transmitted The USB side permits quick setup Just plug in the converter and Windows will install the drivers and set up the converter The USB supplies power so no separate power supply is needed The CR40485 is a cost effective device for transfer serial data over USB _USB RS485 is designed to make serial port expansion quick and simple Connecting to a USB port on a computer or USB hub this device instantly add serial communication ports to your system By plugging the device into the USB port it is automatically detected and installed There are no IRQ amp COM port conflicts since the port doesn t require any additional IRQ DMA or memory on the system This USB RS485 provides instant connectivity to 485 communication devices for factory automation multi drop data collection devices barcode readers time clocks scales data entry terminals PC to PC long distance communications The CR40485 is a cost effective module for transfer serial data over USB It allows you to connect your serial devices to systems using a USB interface Connecting the CR40485 to a PC you get one RS 422 485 port The Self Tuner chip auto tunes the baud rate and data format to the Rs 485 network The CR40485 module derives the power f
12. do not operate this product Cover with cover removed Use Proper Fuse To avoid fire hazard use only the fuse type and rating specified for this product Do Not Operate In To avoid electic shock do not operate this product in wet or Wet damp Conditions damp conditions Do Not Operate In An To avoid injury or fire hazard do not operate this product in an explosive Explosive Atmosphere atmosphere Product Damage Precautions Use Proper Power Source Do not operate this product from a power source that applies more than the voltage specified Use Proper mains Fuse Use only a 20x5mm 0 5A fast acting fuse located at the mains connector The AcNetPro Installation Manual 4 13 Saftey Terms and Symbols Terms in This Manual These terms may appear in this manual WARNING Warning statements identify conditions or practices that could result in injury or loss of life CAUTION Caution statements identify conditions or practices that could result in damage to this product or other property Symbols on the product The following symbols may appear on the product DANGER Protectice Ground High Voltage Earth Terminal EMI Protection ACTEC LTD terminals including AcNetPro or Minilock terminals are all based on microprocessors They are installed in order to operate 24 hours a day In addition since they must often control a given environment ACTEC terminals may be connected to various types of exterior elements such as card read
13. e installed on the board This manual described how to install the controller Refer to the corresponding User Manual of the application installed on the board for details of using the system General Safety Summary Review the following safety precautions to avoid injury and prevent damage to this product or any products connectd to it The controller should be installed at maximum distance of 1 5 meters from the 230v outlet Power disconnection is done by unplugging the system from the mains 230v outlet Service procedures including assembly of the 230v plug must be done by a qualify personnel A safety approval connector has to be used according to the local standards The controller must be unpowered before opening A Safety approval 12V battery back up has to be used according to the local standards Injury Precautions Use Proper Power Cord To avoid fire hazard use only the power cord specified for this product Avoid Electric Overload To avoid electic shock or fire hazard do not apply a voltage to a terminal that is outside the range specified for that terminal Ground the Product This product is grounded through the grounding conductor of the power cord To avoid electric shock the grounding conductor must be to earth ground Before making connections to the input or output terminals of the product ensure that the product is properly grounded Do Not Operate Without To avoid electic shock or fire hazard
14. ers electrical door opener alarm detection device printer mainframe computer and so forth Under such circumstances this kind of system is subjected to some extremely difficult constraints directly related to 1 Electro Magnetic Interferences EMI along the lines connecting the terminal to any exterior elements Undesired voltage may reach thousands of volts in case of lightnings 2 The exterior elements themselves In most cases they are not supplied by ACTEC LTD but are chosen in response to the constraints of the particular installation site local distributors national operating standards etc All ACTEC LTD equipment is provided with internal protection devices against all such interference These devices include varistances protection diodes etc However since ACTEC LTD Terminals may be installed in a variety of operating environments there are a certain number of basic rules of thumb that should be followed in order to provide extra protection It is absolutely imperative that from the moment a ACTEC LTD terminal is installed the individual responsible for the installation rigorously adhere to all the directives listed below Should any of these directives not be rigorously adhered to Crow Data Systems will not assume responsibility for any problems or malfunctions that might be encountered as a result of such non compliance 1 The control unit housing the microprocessor must never be installed inside a high vol
15. for reader No 2 PR 104 Anti Vandal PR 103 Prox PR 106 Prox Pincode SW 7 Fingerprint refer to the relevant Manual Type of cable 8 shielded wires 22 AWG Maximum length 100m Interface 1SO2 clock data or Wiegand data0 data1 PR TYPE READERS CABLE CONNECTION Reader 1SO2 Interface Reader Wiegand Interface ACNET 200 PCB Proxpoint etc PR 03 04 06 etc Reader 1 2 DC DC Red GROUND GROUND Black Ov CLOCK DATA 0 Green CLK1 CLK2 DATA DATA 1 White DAT1 DAT2 DATA RTN If exists DATA RTN GREEN LED If exists BLUE LED Brown Ov RED LED If exists GREEN LED Orange LED1 LED4 BEEPER If exists BEEPER Yellow BUZ1 BUZ2 9 The AcNetPro Installation Manual NOTE 2 Refer to the reader manufacturer instruction manual for reader operation details AcNetPro Dip switches DS1 ISO 2 INTERFACE Clock Data WIEGAND INTERFACE See also note 1 below Any Wiegand card i Any Wiegand card up to 50 bits with parity up to 50 bits with parity checking based on ISO2 format checking based on format PE Data bits PO Any Wiegand card up to 50 bits without parity checking NOTE Bfore connecting the PR 106 make sure to reprogram it to Motorola output signal 5 Read PR 106 instruction for details DOOR CONTACTS AND INPUTS DEVICES A magnetic contact passive infra red unit request to exit switch or any other form of dry contact can be monitored via the T
16. l 22 CROW ELECTRONIC ENGINEERING LTD ISRAEL 12 Kineret St Airport City 70100 Israel Tel 972 3 9726000 Fax 972 3 9726001 E Mail support crow co il www thecrowgroup com LATIN AMERICA 5753 NW 151st Street Miami Lakes FL33014 USA Tel 1 305 823 8700 Fax 1 305 823 8711 E Mail sales crowlatinamerica com www crowlatinamerica com USA 2160 North Central Road Fort Lee NJ 07024 USA Tel 12019440005 Fax 12019441199 E Mail support crowelec com www crowelec com ITALY VIA Giulianello 4 14 00178 ROMA ITALY Tel 39 0676 12912 Fax 39 0676 12601 E Mail info deatronic com AUSTRALIA 142 Keys Road Cheltenham VIC 3192 Australia Tel 61 3 9553 2488 Fax 61 3 9553 2688 E Mail crow crowaust com au www crowaust com au POLAND Powazkowaka 01 797 Warszawa POLAND Tel 48 22 562 3000 Fax 48 22 562 3030 E Mail vidicon vidicon pl MEr ow The Crow Group These instructions supersede all previous issues in circulation prior to June 2008
17. lems arise We recommend erring on the safe side and using shielded cable Shielded cable is only slightly more expensive than unshielded There are many cables available meeting the recommendations of RS 422 and RS 485 made specifically for that application Another choice is the same cable commonly used in the twisted pair Ethernet cabling This cable commonly referred to as Category 5 cable is defined by the EIA TIA ANSI 568 specification The extremely high volume of Category 5 cable used makes it widely available and very inexpensive often less than half the price of specialty RS422 485 cabling The cable has a maximum capacitance of 17 pF ft 14 5 pF typical and characteristic impedance of 100 ohms Category 5 cable is available as shielded twisted pair STP as well as unshielded twisted pair UTP and generally exceeds the recommendations for RS 422 making it an excellent choice for RS 422 and RS 485 systems Power and Earthing Considerations Unlike some RS232 to RS485 converters the CR40485 will always be able to take the power it needs from the PC s USB port It s recommended to connect a solid earth ground connection It is also advisable to connect at least one of the ground pins on the unit s RS422 RS485 connector via a 100R resistor to the ground earth conductor in the RS422 RS485 connecting cable The resistor will help to limit current if connected devices have different ground potentials Installation of the driver for Windows
18. me the system each controller has to have a unique address which is defined with jumpers JP4 amp JP3 AcNetPro is addresses from 00 to 31 throug jumpers DS1 1 to DS1 5 ACNET 1 ACNET 2 ACNET 3 ACNET 4 ACNET 5 ACNET 6 ACNET 7 10 11 12 13 9 14 15 16 17 18 19 20 21 22 24 25 26 27 28 29 30 Fig 8 3 Setting th e controller address through jumpers DS 1 1 to DS 1 5 ACNET 8 16 23 31 13 The AcNetPro Installation Manual 8 PC to ACNETPRO CONTROLLER COMMUNICATION ACCESSORIES 8 1 CR40485 USB RS 485 422 CONVERTER WML OR espe catenin A A N 15 2 Connecting the CR 40485 to RS 485 Devices s sssssessecseeessesseeesseeeeeeeeeesseetaeesees 16 3 Connecting the CR 40485 to RS 422 Devices s scsssessessseseeeeseseesseeeseesteeetaeetseenees 16 BA NIM ONIN Sa eee 17 5 Power and Farthing Considerations ies cdiasaniatutscadivacasastaiciiainsaied censinatensmialuadninaadanecieats 17 6 Installation of the driver for Windows s sssssssssessssssssrssissrssresrrsrssnrresnrsnnrnnnrennenrenrenne 17 7 Dipswiteh Setting sissies owsa sinn ecuacsnasansuatshannetarazcelainiaspiadaitlonsabasembendamisetunininns 18 BGM Nal Spe ificatiONi erecsectesansreeeeactastsescutiesenieseavecetusesectetecvoen sass eucuatanbisceateceeenlcinces 18 CR40485 USB to RS422 RS485 Converter O fzo x O USB to RS485 Converter INSTALLATION INSTRUCTIONS The AcNetPro Installation M
19. mption is more than 24V 1A use an intermediate relay Always install a 120 ohms terminator resistor at both ends of the RS485 line Never connect a controller to the RS485 bus farther than 3 meters Link all the RS485 wire shields together and connect it at the RS232 RS485 interface end and NOT at the controllers end Use a very good earth at the interface Use a surge protection if the region is inclined to lightning like the SP200 unit Never install a controller or its cables near a high voltage line or a heavy duty electric devices Motors transformers high voltage sources etc Never use the same power supply for the controller AND the door opener 21 The AcNetPro Installation Manual CROW ELECTRONIC ENGINEERING LTD Crow WARRANTY POLICY CERTIFICATE This Warranty Certificate is given in favor of the purchaser hereunder the Purchaser purchasing the products directly from Crow or from its authorized distributor Crow warrants these products to be free from defects in materials and workmanship under normal use and service for a period of 24 months from the last day of the week and year whose numbers are printed on the printed circuit board inside these products hereunder the Warranty Period Subject to the provisions of this Warranty Certificate during the Warranty Period Crow undertakes at its sole discretion and subject to Crow s procedures as such procedures are form time to time to repair
20. n J4 serial Port RS232 or RS485 RS232 RS485 to PC or printer 654 JP3 4 123 To be installed if reader 1 2 with RS232 RS485 Wiegand interface NOTE For setting DS1 see page 10 7 The AcNetPro Installation Manual 3 POWER SOURCES AND BOARD CONSUMPTION The board must be powered by 12Vdc Nude without any card reader the board consumption is 100 mA max The maximum consumption authorised through the Vcc of the board is 300 mA NOTES Card readers consuming more than 250mA CANNOT be powered by the AcNetPro Vcc output Asafety approved 12V battery pack has to be used according to the local standards R 4nc R3nc R2nc Rinc R4c R4no R3c R3no R2c R2noRic Rin LLL E Power 12Vdc Supply Ov JP2 RL 4 RL3RL2 RL1 REMINDER DON T CONNECT THE READER S RED WIRE TO VCC OF THE PCB CONTROLLER The AcNetPro Installation Manual 8 4 CARD READERS TYPES AND CONNECTION The AcNetPro controller may recognise many kind of reader technologies selected by jumpers JP4 6 7 8 Hereunder the connection for the most popular one magnetic and proximity For other technologies refer to the relevant manual 4 1 Connecting the Proximity Reader Range It is adviced to use the ACTEC proximity reader range PR 103 104 a 125 KHz models or smart reader a 13 56 MHz model NOTE 1 For the Wiegand interface only Install mini jumper on JP3 for reader No 1 and on JP4
21. neseaenaas 10 6 LOCK DEVICE RELAY OUTPUTS CONNECTION uu cccccccccsccesscssessesceesssesseesseessesseesseesseussousseeesenusaeeveeesseeneas 10 7 RS232 RS485 SERIAL PORT CONNECTION uuu cccccsccssccsesssecssesssesssessseeseeesseesseesseeseseusseusseeuseeseaeusaeusessaeevanes 11 71 RS232 port Jumpers JP2 aciccsnnsnicsscasdarsannassiaancsaarsonntdaenscndinssacvsnnqasnaha tauusendsinaderachanyeaniuaasesagnaauabivaccengents 11 7 2 RS485 port Jumpers IP2 cc scsssssnsirscnscassnensarcccdessuannanasanennssastsnnasesansenssaniadueensnsdcaensdnennseadteesesaunannancaasaneants 11 7 3 Setting the controller address wswciccscsccessesiscnsnsevecccesvacaessnensecneceeeesstrensctt cise ccessvansraentecneewnenseaeeededecsies 13 8 PC to ACNETPRO CONTROLLER COMMUNICATION ACCESSORIES optional ccssesesessssesseseeeeeeeees 14 8 1 The CR40485 USB RS 485 422 converter Installation instructions ccecccsesseceeeeeeeseeeeee ae 14 Met VIMEO CUCU ON E E AAEE A A E T snataseisnastacesatitinstessacsenaeee 15 2 Connecting the CR 40485 to RS 485 deviceS s ssssssresiesnesnunnnnnnnununnnnnnnnnnnnnnnnnnunnnnnnnnnnnnnnnnnnn 16 3 Connecting the CR 40485 to RS 422 devicesS s ssssssresresunsurunnunnnnnnnnnnnnnnnunnunnnnnnnnnnnnunnunnnnnnnnnnn 16 4 CONNECUONS isses sannara Ea aa E A Eaa T aKa aE E aaO 17 5 Power and Earthing ConsiderationS ssssssssssresnssesunsnnsnnununnnnnnnnnnnnnunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn
22. o Installation Manual 10 Important notes 1 1 7 2 1 If the release mechanism has a charge that exceeds the authorised limit or has a strong inductive charge as in the case for example of revolving doors or turnstiles it will be necessary to use an intermediate relay between the system and the charge THE CHARGE MUST BE POWERED WITH A SEPARATE POWER SUPPLY The intermediate relay and the electronic board may be powered with the same power supply the one of the board for example 2 The cable connecting the release mechanism to the control unit or to the intermediate relay must be isolated and there must therefore be a distance of at least 50 cm between this cable and all the other cables RS232 RS485 SERIAL PORT CONNECTION If the controller has to be connected to a PC ora printer at less than 30 meters its RS232 port may be used If the distance is bigger than 30 meters or if several controllers must be connected together to a PC or a printer the RS485 port must be used as follows The characteristics of the serial transmission is asynchronous serial transmission 9600 bauds 8 data bits no parity 2 stop bits RS232 port Jumpers JP2 The three signals Ov Rx and Tx 3 shielded wire 22 or 24 AWG Maximum distance 30m are connected to the PC or the printer as follows D25 plug computer end D9plug computer end ACNET J4 board pins Pin 7 Ov Pin 5 Ov Ov Pin 2 Transmit Pin 3 Transmit Rx Pin 3 Receive
23. oplock system All the eight standard inputs can be set up via software so as to open doors when activated activate sirens bells or just inform security of a change of state of a monitored device Protection against RFI interferences The following must be rigidly adhered to in order to prevent malfunctions or interruptions Ifthe distance between the alarm detector push button etc and the electronic board is greater than 10 meters use a shielded cable and connect the shields to the ground point of the control unit Always ensure that a distance of at least 50 cm separates the connecting cables from both high tension cables and electrical door opener cable ASS 16 15 Ov 14 13 12 11 Ov J6a Example of a Normally Open or Normally Closed switch connected to input 11 controller ACNET LOCK DEVICE RELAY OUTPUTS CONNECTION The Four relays on the controller can support a maximum of 24V 1 Amp Do not try to switch higher voltage than this as it may damage the controller See figure below for details of wiring an electronic release The function of each relay is user definable in the software 12v Ov Ric R1no Always fit a Diode across a DC electronic lock to be fitted at the lock end D22292 CECCCCS Jia WT aya R no Normally Open contact Relay 4 Relay 3 Relay 2 Relay 1 R nc Normally Closed contact R c Common contact of the relay Controller ACNET The AcNetPr
24. or replace free of charge for materials and or labor products proved to be defective in materials or workmanship under normal use and service Repaired products shall be warranted for the remainder of the original Warranty Period All transportation costs and in transit risk of loss or damage related directly or indirectly to products returned to Crow for repair or replacement shall be borne solely by the Purchaser Crow s warranty under this Warranty Certificate does not cover products that is defective or shall become defective due to a alteration of the products or any part thereof by anyone other than Crow b accident abuse negligence or improper maintenance c failure caused by a product which Crow did not provide d failure caused by software or hardware which Crow did not provide e use or storage other than in accordance with Crow s specified operating and storage instructions There are no warranties expressed or implied of merchantability or fitness of the products for a particular purpose or otherwise which extend beyond the description on the face hereof This limited Warranty Certificate is the Purchaser s sole and exclusive remedy against Crow and Crow s sole and exclusive liability toward the Purchaser in connection with the products including without limitation for defects or malfunctions of the products This Warranty Certificate replaces all other warranties and liabilities whether oral written non manda
25. rom the USB port and doesn t need any power adapter It also features a high speed 115 2 Kb s transmission rate and supports various independent RS 422 485 Ports The AcNetPro Installation Manual Connecting the CR 40485 to RS 485 Devices Where 2 wire operation is required the Transmit and Receive signals should be connected together in pairs as below see Figure 2 Make sure to set the DIP SW on PCB to Half Duplex RS 485 2 Wires mode RS 485 Device 1 CR40485 USB to RS485 Converter RS 485 Device 2 Up to 31 devices RS 485 2 Wires RS 485 Device 31 Figure 2 Connecting the CR 40485 to RS 422 Devices Where 4 wire operation is required the Transmit signals should be connected to the corresponding Receive signals of the devices see Figure 3 Set the DIP SW on PCB to the required mode of operation RS 422 Device 1 CR40485 USB to RS485 Converter RS 422 Device 2 Up to 31 devices RS 422 4 Wires RS 422 Device 31 Figure 3 The AcNetPro Installation Manual 16 Connections The RS 422 specification recommends 24AWG twisted pair cable with a shunt capacitance of 16 pF per foot and 100 ohm characteristic impedance While the RS 485 specification does not specify cabling these recommendations should be used for RS 485 systems as well It can be difficult to quantify whether shielding is required in a particular system or not until prob
26. tage electrical power box and must never be placed in close proximity to large transformers or high voltage current source devices Since the controller may require maintenance it is important to consider the accessibility of the unit 2 The AcNetPro board must be separately grounded Therefore one must verify in advance whether the installation site provides adequate grounding facilities 3 The cover or case that contains the control unit housing the microprocessor must be tightly screwed down or locked in place 4 Itis essential to plug the ACTEC terminal s 230 volt sector cable into a clean line i e a line not being used other pieces of heavy equipment or into an length line which has been specifically allocated to the terminal with a good earth ground 5 Never use the system cables guide to pass wires from another system like loud bells electric door openers etc 6 Four categories of cable go to or from the terminal The 230 volt sector cable The cables connecting badge readers alarm entries and push buttons The communication cable The cable connecting the electrical door opener or an exterior release device These categories must be installed as far as possible one from the other The AcNetPro Installation Manual 1 4 Step by step installation Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Step 9 Step 10 Install the AcNetPro housing
27. tory statutory contractual in tort or otherwise In no case shall Crow be liable to anyone for any consequential or incidental damages inclusive of loss of profit and whether occasioned by negligence of the Crow or any third party on its behalf for breach of this or any other warranty expressed or implied or upon any other basis of liability whatsoever Crow does not represent that these products can not be compromised or circumvented that these products will prevent any person injury or property loss or damage by burglary robbery fire or otherwise or that these products will in all cases provide adequate warning or protection Purchaser understands that a properly installed and maintained product may in some cases reduce the risk of burglary fire robbery or other events occurring without providing an alarm but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss or damage as a result Consequently Crow shall have no liability for any personal injury property damage or any other loss based on claim that these products failed to give any warning If Crow is held liable whether directly or indirectly for any loss or damage with regards to these products regardless of cause or origin Crow s maximum liability shall not in any case exceed the purchase price of these products which shall be the complete and exclusive remedy against Crow The AcNetPro Installation Manua
28. xpress written permission of CROW Electronic Engineering Ltd ACTEC Series P N 7102003 Rev B July 2008 The AcNetPro Installation Manual 2 TABLE OF CONTENTS ASINTRODW CTO Nese sisisasccvavancivcsedevavedaiesieesaewied vanctasevecuen stecauassnadans ivstecauxcavssasbvisdacadies aden theeiteaaconvenstvbdeaddancanvents 4 1 1 The AcNetPro controller cccccccccceeueeceeeceueeeueeueuueeueuueuueeueuuaeueevauueesauvanvarsauenssevsseeveness 4 1 2 General Safety SUMIMANY ic siecsececcseccdscsetcsccedceccsevatssecescectctad veachendunsuesdvtarsecseoteeedsrvendecsavevuesacaacscqenseetenseves 4 13 EMI Protectio Murie a Ea ae N eLearn Naaa reS Ad 5 1 4 Step by step installations scisisciscecsssescecacadccsazsieeverssnaestsedacvavsesacteseecsedstuavsdaseseseseecersnavcisaesssiavecacasnenaesersisis 6 2 THE ELECTRONIC BOARD AND THE PCB JUMPERS ccsccssscsssccesscesscessceseseesseesseesseesseessaeusaeesseesenevseeseaenaas 7 3 POWER SOURCES AND BOARD CONSUMPTION cccccccsscesecssccsssseessseeseesseeeseusseeseesseesseeusoeseaeseeevsnsseeevaees 8 4 CARD READERS TYPES AND CONNECTION ccccccscccsccscsssscsesseesssesseeuseeeseesceesseesseeusaessseesseesseussaeusaeveaeevanens 9 4 1 Connecting the Proximity Reader Range 0cceceeeee eee e neces eee eee eee ee eae ee tees eae e nea e eeaeneeatas 9 5 DOOR CONTACTS AND INPUTS DEVICES cccccccccsccsscccesscesscessceeseeesseesseesseesseeseesseesseesseevsaeesonusaeevo
Download Pdf Manuals
Related Search
Related Contents
- Supprimer la nage à contre courant à la fin de la baignade pour manuel d`installation et d`utilisation des adoucisseurs quadplex Worldwide Homefurnishings 403-774 Installation Guide Comprendre Philips DVDR3400 DVD Player/Recorder Palm Smart Phone User's Manual MANUAL DE INSTALAÇÃO Clique aqui e faça o download. Anleitung Copyright © All rights reserved.