Home
PC615N Series
Contents
1. batteries Released electrolyte is harmful to the excessive dust and has adequate air flow Please fetal place the UPS away from other units at least 20 cm to avoid interference DO NOT operate the UPS where the temperature and humidity is outside the specific limits Please check the specs for the limitations 2 Charging Plug in the AC input cord to the wall outlet For the best results suggest charging the battery at least 4 hours before initial use The gt unit charges its battery while connecting to the utility 3 Connection of Equipment Plug in the loads to output receptacles on the rear panel of the UPS Simply turn on the power switch of UPS unit then devices connected to the UPS will be protected by UPS unit 4 Connection of Network To surge protect a network connection connect a network cable from the wall jack outlet to the IN jack of the UPS Then connect a network cable from the OUT jack of the UPS to the network device 5 Connection of Communication UPS equipped with communication port allows monitoring and controlling from computer screen Connect one end of a communication cable to your PC and the other to the com port at the rear of the UPS 4 hours ViewPower is an UPS power management software allowing users to control and monitor UPS straightly from PC monitor Insert ViewPower software CD or download ViewPower software from http www power software download com to your hard drive Follow on screen
2. well as violate local electrical codes Sj _ Inthe event of an emergency press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS 3 G Sa l DO NOT allow liquids or any foreign object to enter the UPS Do not place beverages or Ts Cottle al k on any other liquid containing vessels on or near the unit 0 EPUL ih plaus This unit intended for installation in a controlled environment temperature controlled ALA e 14 USB com port indoor area free of conductive contaminants Avoid installing the UPS in location where 4 Modem Phone Network surge there is standing or running water or excessive humidity protection DO NOT plug the UPS input into its own output Quiet i DO NOT attach a power strip or surge suppressor to the UPS qh DO NOT attach non computer related items such as medical equipment life support equipment microwave ovens or vacuum cleaners to UPS To reduce the risk of overheating the UPS do not cover the UPS cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such Installation amp Operation as space heaters or furnaces SSS Unplug the UPS prior to cleaning and do not use liquid or spray detergent 1 Placement x x DO NOT dispose of batteries in a fire as they may explode Install the UPS in a protected area that is free of a DONOT open or mutilate the battery or
3. ds 3 5mA This pluggable type A equipment with battery installed by the supplier is operator installable r Mi Ha i hich reliabilit and may be operated by laymen a iy k a nd ro hice IGN relapiity Attention Hazardous through electric shock Also with disconnection of this unit from the m pi anced DOOST amp DUC mains hazardous voltage still may be accessible through supply from battery The battery f ASi Cnalgel supply should be therefore disconnected in the plus and minus pole at the connectors of the Green power function for energy saving battery when maintenance or service work inside of the UPS is necessary v DC start function v Auto restart during AC recovery on ge v Provide Modem and phoneline surge production System Description v Built in RS 232 communication port v Compact size light weight Power Switch UPS status LED AC Mode green lighting Battery Mode green flashing 3 AC mode indicator green lighting Important Safety Instructions To safely operate this uninterruptible power supply system please read and follow all instructions 00O carefully Please read this manual thoroughly before attempting to unpack install or operate UPS 4 Battery mode indicator yellow and keep this manual for further reference 3 flashing l ie l 5 5 Fault mode indicator red lighting This UPS utilizes voltages t
4. hat may be hazardous Do not attempt to disassemble the unit 6 AC Mode indicating load level The unit contains no user replaceable parts Only authorized service personnel may Batt Mode indicating battery perform repairs S K S g Internal battery voltage is 12V DC Sealed lead acid 6 cells battery APAC Connection to any other type of receptacle other than a two pole three wire grounded receptacle may result in shock hazard as
5. instructions to complete the software installation After computer is restarted ViewPower is geared and presents as an orange plug icon located in the system tray at the right bottom corner System UPS Log Help w 3 UPS Status Horm System Time 2008 07 15 17 03 DATE TIME 2008 07 15 2008 07 15 2008 07 15 16 41 44 6 Turn On Off To turn on the UPS press power switch lightly To turn off the UPS please press power switch again 7 Green Power Function PC615N 650 and PC615N 850 UPS are equipped with Green Power Function For saving power and protecting battery the method of deep discharging protection is adopted on inverter mode Trouble shooting Use the table below to solve minor problems If any abnormal situations occur that are not listed above please call service technician for assistance Possible Cause Solutions O Low battery Charge the UPS at least 6 hours Battery fault i Replace the battery with the same type of battery The UPS is not turned on Press the power switch again to turn on the UPS Remove some loads first Before reconnecting Problem Alarm continuously The UPS is overload sounds when the equipment please verify that the load matches mains is normal the UPS capability specified in the specs The UPS is overload Remove some critical load Battery voltage is too low Charge the UPS at least 6 hours Replace the battery with the same type of When
6. power fails Battery defect It might be due to high temperature operation environment or battery improper operation to battery The mains is normal Power cord is loose but LED blinks Reconnect the power cord properly Specifications 650VA 850VA 1000VA 1500VA 2000VA 360W 480W 600W 900W 1200W 110 120 VAC or 220 230 240 VAC 81 145 VAC 162 290 VAC CAPACITY INPUT Voltage Voltage Range OUTPUT Voltage Regulation 10 Transfer Time Typical 2 6 ms 10 ms max Simulated Sine Wave 12V 7AHx1 12V 9AHx1 12V 7AHx2 12 V 9 AH x 2 4 6 hours recover to 90 capacity Waveform BATTERY Type amp Number Charging Time PHYSICAL Dimension DxWxH mm 397x146x205 Net Weight kgs 425 ao so m 11 5 Humidity Noise Level USB Product specifications are subject to change without further notice
7. skin and eyes It may be toxic A battery can present a risk of electrical shock and high short circuit current The following precautions should be observed when working on batteries 1 Remove watches rings or other metal objects from the hands PC61 5N Series d J A 2 Use tools with insulated handles 3 Wear rubber gloves and boots 7 User S Man ual 4 4 Do not lay tools or metal parts on top of batteries 5 Disconnect charging source prior to connecting or disconnecting battery terminal Servicing of batteries should be performed or supervised by personnel knowledgeable of Introduction batteries and the required precautions should be taken Keep unauthorized personnel This UPS is specially aimed for use with multi function personal computer It is equipped with away from batteries boost amp buck AVR to stabilize the wide input voltage range It also comes with high efficient When replacing batteries replace with the same number of the sealed lead acid batteries switch mode battery charger This charger design minimizes power loss to save charging time he socket outlet shall be installed near the equipment and easily accessible The built in DC start function enables the UPS to be started up without a supply of AC power The With the installation of the UPS it should be prevented that the sum of UPS and the main features of this UPS are listed below connected load leakage current excee