1. CJ series High speed Data Storage Unit SPU Unit CJ1W SPU01 V2 High speed Collection of System Data CSM_CJ1W SPU01 V2_DS_E_7_1 The CPU Unit can collect large amounts of process data operation data inspection data and other controlled system data quickly and automatically save the data in external storage media as CSV files CJ1W SPU01 V2 Features e There is no need to write ladder programming to collect data Even with an existing system just mount an SPU Unit and add it to the I O tables to start data collection e The total size of variables that can be specified to collect data is 7 776 words e Use specified times or events as triggers to record the contents of specified words in I O memory in the CPU Unit e In Data Storage Mode up to 65 data collection patterns are possible with one basic collection pattern and data collection patterns 1 to 64 Combine the collection patterns with events to simultaneously collect many different types of data e Collected data can be stored in PC cards or in a computer connected via Ethernet Data Management Middleware can be used to make a few simple settings to store the data in a host computer e Recipes can be used to batch write numeric or text string data such as production parameters in the memory areas of the CPU Unit Recipe data can be saved in a Memory Card in the SPU Unit to easily enable process switchovers e SPU Units with a unit version of 2 1 or later also p
2. BU606F both by OMRON is used as the uninterruptive power supply Connecting the BU70XS or BU606F by Special Cable Connect the Uninterruptive Power Supply to the COMM port on the CJ1W SPU01 V2 using the Special Cable For the UPS setting in the Setup Tool set the power failure signal as a negative logic input UPS Applicable Special Cable BU606F BUC10 BU70XS BUC16 Connecting the BU70XS or BU606F by Cable or Connecting to Another UPS The SPU Unit detects a power failure by the CS signal input turning ON Therefore wire the connection between the CJ1W SPU01 V2 and the uninterruptive power supply UPS so that when a power failure occurs the RS signal output from the COMM port at the SPU Unit is returned to the CS signal input For the UPS setting in the Setup Tool set the power failure signal as a positive logic input omrRON CJ1W SPU01 V2 e COMM Port Specifications Connector type D Sub 9 pin male 4 40UNC OROROORO oo0oo0o0o 0 oO Connector Pin Arrangement Pin No Abbrev Signal name 1 0 1 NC Not used 2 RD Receive Data Input 3 SD Send Data Output 4 NC Not used 5 SG Signal Ground 6 NC Not used 7 RS Request to Send Output 8 cs Clear to Send Input 9 NC Not used Shell FG Shield Connection Example 1 Connecting the BU606F with Cable SPU RS232C TR UPS Pin 7 RS N 4 Pin 2 BU p I Pin 8 CS iD Pin 4 COM i
3. The program that performs SPU Unit settings and operations e Microsoft NET Framework Version 1 1 Redistribution Package Microsoft NET Framework Version 1 1 is required to run the SPU Console The Microsoft NET Framework Version 1 1 Redistribution Package provided in the package can be used to install Microsoft NET Framework in the computer e SPU Unit System Data This system data is transferred to the SPU Unit e FinsGateway Version 2003 This communications middleware is required to run the SPU Console e Manual Data The manual data includes the SPU Unit Operation Manual Cat No V236 the SPU Console Operation Manual Cat No V230 the SPU Console Version 1 3 Operation Manual Cat No V231 and the SPU Console Version 2 2 Operation Manual Cat No V237 in PDF portable document format omrRONn CJ1W SPU01 V2 SPU Unit Data Management Middleware EDMS The SPU Unit Data Management Middleware hereafter the EDMS is software that reads CSV format files from an SPU Unit and copies the files to a specified folder on a computer hard disk over an Ethernet network With version 2 0 or higher the collected data can be stored in a database SPU Unit Data Management Middleware EDMS Computer SPU Unit CPU Unit CSV files ey E Dw Collected data Database Storage Function The collected data can be stored in a dat
4. gt o Connection Example 2 Connecting the BU70XS with Cable SPU RS232C TR UPS Pin 7 RS L 3 k Pin 8 BU 11 Pin 8 CS A po Wy Pin 5 COM 0 omRONn CJ1W SPU01 V2 Dimensions Unit mm CJ1W SPU01 V2 os o0 lo J U UN o ee 9 65 Related Manuals Name Cat No Contents CS1W SPU01 V2 SPU02 V2 CJ1W SPU01 V2 V236 Describes the installation and operation of the SPU Units SPU Units Operation Manual WS02 SPTC1 V2 gt SPU Console Ver 2 1 Operation Manual V237 Describes the installation and operation of the SPU Console Ver 2 1 WS02 EDMC1 V2 V232 Describes the installation and operation of the SPU Unit Data Manage SPU Unit Data Management Middleware User s Manual ment Middleware EDMS omRONn Terms and Conditions Agreement Read and understand this catalog Please read and understand this catalog before purchasing the products Please consult your OMRON representative if you have any questions or comments Warranties a Exclusive Warranty Omron s exclusive warranty is that the P
5. in doubt special part numbers may be assigned to fix or establish key specifications for your application Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product Errors and Omissions Information presented by Omron Companies has been checked and is believed to be accurate however no responsibility is assumed for clerical typographical or proofreading errors or omissions 2015 7 In the interest of product improvement specifications are subject to change without notice OMRON Corporation Industrial Automation Company http www ia omron cony c Copyright OMRON Corporation 2015 All Right Reserved
6. 4V SPU Unit High speed Data Storage Unit en epu CF Card Type I II x 1 slot ipon Bus Units Use an OMRON HMCEFI 10 100Base TX 1 0 56 CJ1W SPU01 V2 UC1 CE Memory Card Note 1 There is no accessory for the CJ series SPU Unit 2 This unit cannot be used with the Machine Automation Controller NJ series Support Software Product name Specifications Model Standards SPU Console Functions Unit settings sampling settings etc for High speed Data Collection Units Support Software required for making settings for this Unit WS02 SPTC1 V2 PP os Windows XP Vista 7 or 8 Option Product name Specifications Model Standards Function Data files collected by SPU Unit Data 1 license WS02 EDMC1 V2 SPU Unit Data Management Management Middleware are automatically acquired at the personal Middleware computer and can be registered in a database 5 licenses WS02 EDMC1 V2L05 OS Windows XP Vista 7 or 8 Flash memory 128MB Note HMC EF183 Memory Card is Memory Cards Flash memory 256MB required for data HMC EF283 N L CE collection Flash memory 512MB HMC EF583 Industrial Switching Hubs product Specifications c r roduc urren AO Appearance aos No of Failure consumption A Model Standards pors detection 3 No 0 22 W4S1 03B Quality of Service QoS UC CE Industrial EtherNet IP control data priority Switching Failure detection Hubs lt Broadcast storm and LSI error detection 5 No 0 22 W4S1 05B y 10 100BASE TX Auto Negot
7. ONn CJ1W SPU01 V2 Functions Supported by SPU Units According to Unit Versions CJ1W SPU01 V2 Unit version of SPU Unit Unit ver 2 0 Unit ver 2 1 Unit ver 2 2 Function Recipe function Supported Expanded recipe function Not supported Supported Copy option Supported CHANNEL_BLOCK data type Supported FTP communications Not supported Supported Record counter and file copy flag Not supported Supported SPU Console Compatibility with Unit Versions of SPU Units CJ1W SPU01 V2 Unit version of SPU Unit 3 SPU Console Unit ver 2 0 Unit ver 2 1 Unit ver 2 2 SPU Basic Software SPU Console version 1 X Cannot be connected Cannot be connected Cannot be connected Can be connected Can be connected SPU Console version 2 0 Can be connected Initial Setting Wizard cannot be Initial Setting Wizard cannot be used used Can be connected SPU Console version 2 1 Can be connected Can be connected Initial Setting Wizard cannot be used SPU Console version 2 2 Can be connected Can be connected Can be connected Note 1 SPU Console versions lower than version 2 0 cannot connect to SPU Units with a unit version of 2 0 or higher 2 SPU Console version 2 0 or 2 1 can connect to SPU Units with a unit version of 2 2 However the Initial Setting Wizard cannot be used for unit version 2 2 in this case Use the Initial Setting Wizard that is provided with CPU Console version 2 2 or pe
8. SPU01 V2 Item Specifications Data Storage Mode Beelpe foncion Unit Ver 2 0 or later Number of fields 10 000 File format CSV Recipe files The file size is restricted by the size of file that can be stored in the recipe folder Records Specified by the user Kumpar ot No limit but restricted by the file size that can be stored in the recipe folder Writing method Conversion method Each field is written to the specified address in the specified data type Continuous region method Data written to continuos memory addresses Searching for recipe keys Searching within files The text string that was passed as the key is searched for in the target search columns in the recipe files and the rows for any matches that are found are extracted as recipe data Searching for file names The text string that was passed as the key is searched for in the recipe file names i e a search is made for key csv and the files with matching files names are used as recipe files just like previous versions Key list search A search is made for recipe keys with the method used for unit version 2 0 1 In both cases the sampling cannot be performed faster than the CPU Unit s cycle time The actual sampling interval will always be longer than the CPU Unit s cycle time even if the sampling interval is set shorter than the cycle time 2 The Data Collection Patterns use the data collected by the Bas
9. Windows 7 32bit 64bit Microsoft Windows 8 32bit 64bit Application platform Microsoft NET Framework Version 1 1 Microsoft NET Framework Version 2 0 Communications platform FinsGateway Version 2003 Functions Unit information Unit setup variable settings collection pattern settings event settings recipe set tings trend graphs and reports Unit information Monitor SPU Unit operating status and error information are displayed Operation Operations such as starting sampling Unit setup IP network settings FINS network settings Variable settings Setting items to sample by specifying I O memory addresses using variables Collection pattern settings Collection pattern settings period file designations for saving etc Recipe settings Data Storage Mode Recipe settings recipe file write destination key etc Event settings in Data Storage Mode Memory event settings Settings for conditions according to changes in memory e g bits turning ON Scheduler settings Settings for schedules e g specific times time intervals Trend graphs Historical trends CSV files are read and displayed Realtime trends Sampling Mode Current sampling data is read and displayed in trend graphics in real time Software Package Contents The WS02 SPTC1 V2 contains the following software and data e SPU Console Execution Program
10. abase either at the press of a button or in the background after starting the computer Ethernet Copy Function The collected data can be copied to the computer either at the press of a button or in the background after starting the computer EDMS Structure The EDMS consists of the following programs EDMS EDMS Console FinsGateway Service Copy Setting Window Copy Task Service Database Storage Setting Window Database Storage Service Microsoft NET Framework1 1 Microsoft Windows XP Vista 7 8 e Copy Task Service The Copy Task Service copies files from an SPU Unit and saves them to a computer hard disk on the same network The service operates in the background and is used to monitor SPU Units e Database Storage Service The Database Storage Service stores the files that are copied to the computer into a database The service operates in the background e EDMS Console The EDMS Console is a user interface program that provides access to the setting windows It accesses the Copy Setting Window for example to allow the user to input Copy Task Service settings specify operations and monitor operating conditions The program displays the files that have been copied to the computer in a list that can be used for data management The Database Storage Windows enable setting the database storage service controlling the storage operation and monitoring operating status EDMS Sp
11. ch symbol delimited with com ma records delimited with carriage returns Any one of the following methods can be used Number of The number of records can be specified i sampling result e A time period can be specified The number of records is calculated automat records stored in ically from the time period and interval between samples one file e With a version 1 2 or later SPU Unit the number of records can be left unspec z ified In this case data is added to the file until data collection is stopped Saving files Records are added to one file from the start of data collection until the end Instead of directly storing the values collected from the CPU Unit s I O memory Scaling the collected values can be scaled with a linear equation or upper lower limit range before storage unit version 1 2 or later File size 2 GB per file Record size Specified by user Number of i records Specified by user or calculated automatically Saving method Data can be saved to a single file or multiple files up to 1 200 files Network communications Windows network shared folders Files in the Memory Card inserted in the PC card slot in the SPU Unit can be shared with a Windows XP Vista 7 or 8 personal computer FTP FTP server client provided Network communications FINS communications e FINS server to execute FINS command e Routing to transfer FINS messages omRONn CJ1W
12. ecifications Item Description Model WS02 EDMC1 V2 Processor Intel Pentium Celeron or compatible processor CD ROM drive Required for installation System requirements Display Super VGA 800 x 600 or better high resolution video adaptor and monitor Mouse Mouse supported by the applicable OS Network card Computers without a LAN port require an Ethernet network card sold separately omRONn CJ1W SPU01 V2 Item Description Microsoft Windows 8 32bit 64bit Microsoft Windows 7 32bit 64bit Microsoft Windows Vista os Microsoft Windows XP Professional Microsoft Windows XP Home Edition Microsoft Windows Server 2012 Microsoft Windows Server 2008 Microsoft Windows Server 2003 Microsoft NET Framework version 1 1 Microsoft Data Access component 2 6 or later System requirements Application platform execution environment Communications platform FinsGateway version 2003 Other software requirements SPU Console sold separately required to input SPU Unit settings SPU Units can be registered by specifying the IP address and name of the Unit Registration of applicable SPU Units same for the SPU Console Copies files from the Memory Card in a registered SPU Unit to a specified folder on a computer hard disk The function is enabled only when two or more is set in the Number of files Field from the SPU Console 256 max Start Button or automatically on computer startup Settable number of c
13. iation 5 Yes 0 22 W4S1 05C CE Mountable Racks NJ system CJ system CJ1 CJ2 CP1H system NSJ system Model Expansion Expansion Expansion CPU Rack Rack CPU Rack Backplane CP1H PLC NSJ Controller Backplane 16 Units CJ1W SPU01 V2 Not Supported 16 Units per CPU Unit 1 2 Units 2 Not supported per CPU Unit 1 1 The number of Units that can be mounted depends on the power supply capacity CJ1W PA202 4 Units max CJ1W PA205 CJ1W PD025 8 Units max 2 A CP1W EXT01 CJ Unit Adaptor is required omrRONn CJ1W SPU01 V2 Functional and Performance Specifications Item Specifications Unit model number CJ1W SPU01 V2 Applicable CPU Units CJ Series Unit classification CPU Bus Unit Unit number Oto F Mounting location CPU Backplane or CJ series Expansion Backplane No of Units per PLC 16 Unit max Phe GE Toe PA a Memory Card Interfaces COMM port Connects to an uninterruptive power supply UPS for detection of power failure Ethernet LAN ports One port 10 100Base TX RJ45 Modular Connector UPS power failure input None UPS connected to COMM port Unit number switch UNIT Rotary switch Sets the unit number of the Unit as a CPU Bus Unit Select switch SELECT Toggle switch Sets the number of the command to execute Settings and operation Sie HOG ENER Pushbutton switch Confirms and starts execution of the command number set using the select swi
14. ic Collection Pattern so the data will be collected at the Basic Collection Pattern s interval even if the Data Collection Pattern s interval is set shorter than the Basic Collection Pattern s interval 3 The actual Basic Collection Pattern interval will always be longer than the CPU Unit s cycle time even if the sampling interval is set shorter than the cycle time Note For details refer to CS1W SPU01 SPU02 V2 CU1W SPU01 V2 SPU Units Operation Manual Cat No V236 omRONn CJ1W SPU01 V2 SPU Console Setting Monitoring Software Specifications The SPU Console is a software product used for OMRON s Storage and Processing Unit called the SPU Unit to set and operate the SPU Unit monitor operating status errors display trend graphs and perform other operations from a personal computer SPU Console Specifications Item Specifications Model number WS02 SPTC1 V2 SPU Console Ver 2 2 System requirements Computer hardware Computer that meets the system requirements for Microsoft Windows CD ROM drive Required for installation Display Super VGA 800 x 600 or better high resolution video adapter and monitor Mouse Must conform to the models supported by the applicable OS Network card A separate Ethernet network card is required for computers that do not have a LAN port Os Microsoft Windows XP Home Edition Microsoft Windows XP Professional Microsoft Windows Vista Microsoft
15. ine system or other application or use Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application product or system Buyer shall take application responsibility in all cases NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS AND THAT THE OMRON PRODUCT S IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM Programmable Products Omron Companies shall not be responsible for the user s programming of a programmable Product or any consequence thereof Performance Data Data presented in Omron Company websites catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty It may represent the result of Omron s test conditions and the user must correlate it to actual application requirements Actual performance is subject to the Omron s Warranty and Limitations of Liability Change in Specifications Product specifications and accessories may be changed at any time based on improvements and other reasons It is our practice to change part numbers when published ratings or features are changed or when significant construction changes are made However some specifications of the Product may be changed without any notice When
16. les are detected 2000 2002 2003 Storage timing Microsoft Access Database storage function Applicable databases Microsoft SQL Server 2000 2005 Oracle Database 10g2 Settable cycle for monitoring when there are storable files Copy folder monitoring cycle Default 10 s Used to check whether storage is in progress monitoring for storable files or stopped Status indicators Press the Display of log Button to display the operating status or an error log list that shows the month day year time and de scription Log display The SPU Unit version 1 2 or later only and CPU Unit clocks are periodically synchronized with the SPU clock synchronization function computer clock Software Package Contents The WS02 EDMC1 V2 software package contains the following items e EDMS Installation Program The EDMS installation program is used to install the Copy Task Service and EDMS Console on a computer e Microsoft NET Framework Version 1 1 Redistributable Package Microsoft NET Framework Version 1 1 is required to run the SPU Console The Redistributable Package provided in the software package can be used to install NET Framework on the computer e FinsGateway Version 2003 The FinsGateway version 2003 communications middleware is required to run the SPU Console e Operation Manual The SPU Unit Data Management Middleware User s Manual Cat No V232 is included in PDF format in the software package omrR
17. ns 100 ms min Data Storage Mode Copy option Basic Collection Pattern Cannot be set Unit Ver 2 0 or later Data Collection Patterns Up to 10 patterns ON GPU CIO Area WR Area HR Area AR Area DM Area and EM Area banks 0 to C nit O memory CJ2 0 to 18 areas Specify the desired CPU Unit I O memory area data area with a variable The data type can be specified with the variable Specifying O The variables can be managed in groups memory areas Variable data BOOL INT UINT DINT UDINT REAL LREAL STRING types CHANNEL UINT BCD UDINT BCD WORD DWORD 3 CHANNEL BLOCK Shared Sampling Mode and Data Storage Mode settings Maximum number 7 776 words total for all variables of variables Set whether or not to use a record condition Record Condition If a record condition is used sampling data is stored within the SPU Unit only when setting the record condition is met For example sampling data can be recorded only while a specified bit is ON or a specified word contains a particular value comparison CPU Bus Unit Area Data exchange e CPU Unit to SPU Unit Command execution such as starting stopping sam with the CPU Unit pling clearing a sampling file or saving a sampling file e SPU Unit to CPU Unit SPU Unit status information CSV files Indices record number time stamps hh mm ss ms ns Collected data file sampling indices serial numbers starting at 0 when sam format Record contents pling is started data for ea
18. ns Back of Unit Name Function Unit number switch UNIT NO Sets the unit number of the SPU Unit as a one digit hexadecimal value Do not set the same unit number for more than one CPU Bus Unit under the same CPU Unit DIP switch DIP SW Used for system settings Card button CARD SW Press this button to allow the Memory Card inserted in the Memory Card slot to be removed Card eject button Press to remove the Memory Card Select switch Sets the command to be executed The command number will be displayed on the seven segment display Enter button Executes the command set using the select switch Indicators The following indicators show the operating status of the Unit RUN ERC ERH COMM CARD and LAN Seven segment display Displays error information and the operating status of the SPU Unit Displays the command number when the select switch is operated Displays the IP address and other results of command execution Memory Card slot The slot used to insert a Memory Card LAN port LAN communications port Connects to 10Base T 100Base TX cables COMM port Connects to the power failure signal from an uninterruptive power supply UPS Connecting the Power Failure Signal CJ1W SPU01 V2 With the CJ1W SPU01 V2 the power failure signal from an uninterruptive power supply UPS is connected to the COMM port Special Cable can be used when either the BU70XS or
19. opies Copy start conditions Files will be saved to the computer hard disk over the network automatically when copying is enabled data collection has stopped or files have been transferred Copy timing Storage location Any specified folder File names can be created automatically using one or any com bination of the following objects Any text string the name of the copy the name of the source SPU Unit the time or date month day year the file was copied consecutive file numbers the date or time of the start record and the date or time of the last record Copy function Saved file name Settable cycle for monitoring when copying is enabled Default 10 s Used to check starting started monitoring copying copying stopped and error status conditions Copy monitoring cycle Status indicators Press the Display of log Button to display the operating status or an error log list that shows the month day year time event ID and description Log display Data files that are copied to a specifi function is enabled only when three ied folder on a computer hard disk are stored in a database The or more is set in the Number of files Field from the SPU Console Settable number of data base stor age services 65 max Database storage start conditions Start Button or automatically on computer startup Files will be automatically stored in the database as soon as storable fi
20. rform the initial settings with the CPU Bus Unit settings of the CX Programmer 3 SPU Console version 2 2 can connect to SPU Units with a unit version of 2 0 or 2 1 In this case the SPU Console will operate in the version that corresponds to the unit version of the SPU Unit omROn External Interface CJ1W SPU01 V2 CJ1W SPU01 V2 7 oy A A a ow Dm s 7 segment display 1 00 na ha ero Indicators c gt EA i Card eject button IE E yur Unit number switch LI I i ae Card button ca i Memory Card slot Hi DIP switch E TAN COMM port i UF Power interrupt signal input CAN pori E l i Select switch HL J E N Enter button ll x 3 DIN Track mounting pi
21. roducts will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron or such other period expressed in writing by Omron Omron disclaims all other warranties express or implied b Limitations OMRON MAKES NO WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED ABOUT NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right c Buyer Remedy Omron s sole obligation hereunder shall be at Omron s election to i replace in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof the non complying Product ii repair the non complying Product or iii repay or credit Buyer an amount equal to the purchase price of the non complying Product provided that in no event shall Omron be responsible for warranty repair indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled stored installed and maintained and not subject to contamination abuse misuse or inappropriate modification Return of any Products by Buyer must be approved in writing by Om
22. ron before shipment Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components circuits system assemblies or any other materials or substances or environments Any advice recommendations or information given orally or in writing are not to be construed as an amendment or addition to the above warranty See http www omron com global or contact your Omron representative for published information Limitation on Liability Etc OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED IN CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY Further in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted Suitability of Use Omron Companies shall not be responsible for conformity with any standards codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product At Buyer s request Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product mach
23. rovide an FTP client This enables sending files of collected data to an FTP server on a host computer eliminating the need to write programming to store data in the host computer System Configuration SPU Console F Setting Monitoring SPU Unit CPU Unit Software Hub or other network device LAN straight cable LAN straight cable commercially available commercially available Windows is a registered trademark of Microsoft Corporation in the United States and other countries Other company names and product names in this document are the trademarks or registered trademarks of their respective companies oOmROoOnN Ordering Information CJ1W SPU01 V2 International Standards e The standards are abbreviated as follows U UL U1 UL Class Division 2 Products for Hazardous Locations C CSA UC cULus UC1 cULus Class Division 2 Products for Hazardous Locations CU cUL N NK L Lloyd and CE EC Directives e Contact your OMRON representative for further details and applicable conditions for these standards SPU Unit High speed Data Storage Unit Pee re Current Specifications o of unit consumption Unit type produci H numbers al ay Model Standards Tame located PC Card slot Ethernet LAN port 5V 2
24. started e Start with an SPU Console operation e Start with the SPU Unit s front panel command buttons Specify the command number e Start from the CPU Unit s ladder program Interval User specified intervals 1 Realtime sampling 5 ms min Normal sampling 100 ms min Data Storage Mode Unit Ver 1 2 or later Data Collection Patterns Basic Collection Pattern 1 pattern required Data Collection Patterns Up to 64 patterns Starting methods Any one of the following methods can be used e Start when a specified event occurs Use a memory event or scheduled event For details see the description of Data Collection Patterns 1 to 64 below e Start automatically when SPU Unit is started e Start with an SPU Console operation e Start with the SPU Unit s front panel command buttons Specify the command number e Start from the CPU Unit s ladder program Basic Collection Pattern required Either of the following methods can be used to start when an event occurs e Memory events Start when a CPU Unit bit or word value matches a spec ified condition Up to 500 memory events can be specified Data Collection Patterns 1 to 64 Sampling e Scheduled events Start at a specified time or time interval Up to 16 sched uled events can be specified User specified intervals 2 3 Interval Basic Collection Pattern 5 ms min Data Collection Patter
25. tch DIP switch DIPSW DIP switch System settings Card button Pressed to release the Memory Card inserted in the Memory Card slot The Memory Card can then be removed LED indicators RUN ERC ERH COMM LAN1 LAN2 and CARD e Displays error information and operating status of the SPU Unit Indications A e Displays the command number set on the select switch egmond play Displays the IP address e Display other information e Sampling Functions e Saving files e Network communications e Recipe function Operating modes Data Storage Mode and Sampling Mode Either mode can be selected with the Change Operating Mode command Current consumption 5 VDC 560 mA max SPU Unit only Other Memory Card HMC EF 120 mA max Supplied from Power Supply Unit Dimensions 51 x 90 x 65 mm W x H x D Weight Use the HMC EF 180 g max Memory Card from OMRON Normal operation may not be possible with any other compact flash cards General Specifications Specifications conform to the general specifications of the CJ series CPU Units omrRONn Detailed Specifications CJ1W SPU01 V2 Item Sampling Mode Sampling patterns Specifications Realtime sampling 1 pattern Normal sampling Up to 3 patterns Starting methods Any one of the following methods can be used e Start automatically when SPU Unit is
Download Pdf Manuals
Related Search
Related Contents
Manual_Motosierra 45ccy50cc 家具調トイレ 桐匠 〈標準便座〉 Philips AV cable for portable DVD player CRP270 ASUS B53V User's Manual Le lien s`ouvre dans une nouvelle fenêtreInformations techniques 取扱説明書(Doテロップ) afrosai-e - La Cour de Comptes IGEMS Release 8 User Manual Geovision GV-AS810 Copyright © All rights reserved.