Mi806 - Milwaukee Instruments

image

Contents

1. Press and hold the ON OFF key until CAL is displayed on the lower LCD Release the ETa button and the message 7 01 pH USE or 6 86 pH USE for NIST buffer set will be dis Played For a single point pH calibration place the probe in any buffer fromthe selected set e g PH 4 01 or 7 01 6 86 or 10 01 9 18 The meter will auto matically recognize the buffer value store the calibration point and reum to normal node If using pH 7 01 or pH 6 86 after recognition of the buffer press the ON OFF button to retum to nonmel node For a two point pH calibration place the probe in PH 7 01 buffer or pH 6 86 if the NIST buffer set wes selected The neter will recognize the buffer value and then display pH 4 01 USE Place the probe in the second buffer pH 4 01 or 10 01 or if using NIST pH 4 01 or 9 18 When the second buffer is recognized the LCD will display OK for 1 second and the meter will retum to normal node The CAL tag is displayed on the LCD to indicate that the meter is calibrated EC TDS OPERATIONS The user can select the EC TDS conversion factor CONV as well as the B coefficient BETA for autorratic tenqperature compensation Enter the EC or TDS rrode with the RANGE key then press and hold the ON OFF key until TEMP is displayed on the secondary LCD Press this key again to show the current conversion fac tor CONV Press the SE
2. appears on the LCD release the button Store the electrode with a few drops of storage solution in the protective cap TAKING pH MEASUREMENTS Always remove the electrode protective cap before taking any nreasurerrent If the electrode has been left dry soak the tip bottom 2 5 an in M10000 rinse solution for a few minutes to reac tivate it Select the pH range with the RANGE key Intrerse the tip 2 5 cn of the probe into the sample and stir gently Read the pH value when the dock symbol stops blinking PH CALIBRATION PROCEDURE A Preparation Buffer solutions 1 pH 7 01 6 86 IMA9007 MA9006 2 pH 4 01 MA9004 for acidic calibration pH lt 7 or pH 10 01 9 18 MA9010 MA9009 for alkaline range pH gt 7 Use two beakers for each buffer solution one bea ker for rinsing the probe the other for calibration In this way the cross contamination between solutions is minimized B Procedure Enter the pH mode with the RANGE key Select calibration buffer set press and hold the ON OFF key until the LCD shows TEMP Press again this key and the BUFF message will appear then select the desired buffer set with the SET key 7 01 pH BUFF for standard solutions pH 4 01 7 01 10 01 or 6 86 pH BUFF for NIST solutions pH 4 01 6 86 9 18 Press ON OFF again to exit Rerrove the protective cap then intrerse the probe in the first buffer solution
3. T button to change the value then press again this key to show the current tenpera ture coefficient BETA Press SET to change the value then press ON OFF key retum to normal operation For taking EC or TDS rnreasurerrerts inrrerse the probe in the solution to be tested Select either EC or TDS rrode with RANGE Stir gently and weit for the reading to stabilize the dock symbol stops blinking UBS rrinays LUNN v EC TDS CALIBRATION PROCEDURE Clean the probe with M10000 solution Enter the EC mode with the RANGE key Intrerse the probe in MA9030 12 88 nS cn calibration solution Press and hold the ON OFF key until CAL is displayed on the LCD Re lease the button and the nes sage 12 88 n6 USE appears The neer will perfonmautormatic calibration and then display OK for 1 second before retuming to nomal nod e The calibration is now complete and the CAL tag is displayed on the LCD to indicate that the neter is calibrated BATTERY REPLACEMENT The neter shows the remaining battery percentage every tirre it is switched on When the battery level is below 5 the battery syrrbol on the bottomleft of the LCD lights up to alert the user The neter is also provided with BEPS Battery Error Prevention System which autorratically switches the neter off if the battery level is so low to cause erroneous readings It is recommended to replace imrediately th
4. USER MANUAL MI 806 pH EC TDS Temperature Portable Meter e amp SET CAL Mi 806 Combined meter pH EC TDS temperature MARTINI instruments Sia eee MARTINI instruments 0 90 1Y908IALLS GENERAL OPERATION The neter is supplied com plete with a IV battery Re mowe the battery cover on the back of the neter and install the battery while pay S ing attention to its polarity Connect the MA851D 1 probe to the meter and tum it on by pressing ON OFF At start up the LCD shows the percentage of the re maining battery life for a few seconds and then the cur rent reasurerrent To select the tenperature nreasurenrent unit C or F press and hold the ON OFF key until TEMP and the current ternperature unit are displayed on the secondary LCD Use SET to select the unit and then press ON OFF a couple of tines to reum to nomal node To activate the HOLD func tion keep pressed the HOLD key The mea sured value will be frozen on the display and the HOLD message appears on the secondary LCD To set the measurement range pH US pom press the RANGE key The chosen mode will be stored until next change Before taking any measurement make sure that the meter has been calibrated the CAL tag is displayed on the LCD After nmeasurerrents switch the meter off by pressing the ON OFF key The OFF n s sage
5. e battery Tum the meter off remove the battery compartment cover from the rear of the meter and replace the rundown 9V battery with a new one Install the battery while paying attention to its polarity and reat tach the cover NOTES e If reading is overrange the display will flash the closest full scale value e To dear a previous calibration press ON OFF after entering the calibration mode The lower LCD will display ESC for 1 second and the rreter will retum to normal mode The CAL symbol on the LCD will disappear and the meter is reset to the default calibration ACCESSORIES MA851D 1 Amplified pHEC TDS Terperature probe with DIN connector and 1 m 3 3 cable MA9004 PH 4 01 buffer solution 230 m bottle MA9006 PH 6 86 buffer solution 230 m battle MA9007 PH 7 01 buffer solution 230 m bottle MA9009 pH 9 18 buffer solution 230 m bottle MAg9010 PH 10 01 buffer solution 230 mi MA9030 12 88 n6 cmsolution 230 mi MA9015 Probe storage solution 230 mi bottle MA9016 General deaning solution 230 mi M10000B Rinse solution 20 m 25 pcs WARRANTY This instrument is warranted against defects in mate rials and manufacturing for a period of two years from the date of purchase Probe is warranted for 6 months If during this period the repair or replacement of parts is required where the damage is not due to negli gence or erroneous operation by the user please return the parts to eith
6. er distributor or our office and the repair will be effected free of charge Damages due to accidents misuse tampering or lack of prescribed maintenance are not covered SPECIFICATIONS RANGE 0 00 to 14 00 pH 0 00 to 20 00 mS cm 0 00 to 10 00 ppt 0 0 to 60 0 C or 32 0 to 140 0 F 0 01 pH 0 1 mS cm 0 01 ppt 0 1 or 0 1 F 0 01pH 2 FS EC TDS 0 5 or 1F 0 02 pH 2 FS EC TDS 0 5 or 1F TEMPERATURE Automatic from 0 to 60 C COMPENSATION B adj from 0 0 to 2 4 C pH CALIBRATION 1 or 2 point with automatic buffer recognition EC CALIBRATION Automatic 1 point EC TDS FACTOR CONV Adj from 0 45 to 1 00 PROBE included MA851D 1 amplified pH EC TDS Temperature probe with DIN connector and 1 m 3 3 cable RESOLUTION ACCURACY 25 C TYPICAL EMC DEV ENVIRONMENT 0 to 50 C 32 to 122 F 100 RH max BATTERY TYPE 1 x 9V alkaline included BATTERY LIFE approx 300 hours AUTO OFF after 8 minutes DIMENSIONS 200 x 85 x 50 mm WEIGHT 260 g with battery

Download Pdf Manuals

image

Related Search

Related Contents

indications réactif protocole performance références - Sigma  Motores sumergibles rebobinables de 6", 8", 10" y 12"  Jensen JiSS-330 User's Manual  DIAG53AAX - Motorisation de portail Adyx, Diagral by Adyx  PX1304 POGO PUMP ASSEMBLIES  Hunter 53249 Use and Care Manual  Nobo Velcro Spots  eSMSpro  Unix/Linux/Mac  Transmitter Operating Instructions  