Home
Color Kinetics ColorBlast12TR
Contents
1. ENVIRONMENTAL SPECIFICATIONS TEMPERATURE RANGE 40 F to 122 F 40 C to 50 C operating temperature A F to 122 F 20 C to 50 C starting temperature LED SOURCE LIFE n traditional lamp sources lifetime is defined as the point at which 50 of the lamps fail This is also termed Mean Time Between Failure MTBF LEDs are semiconductor devices and have a much longer MTBF than conventional sources However MTBF is not the only consideration in determining useful ife Color Kinetics uses the concept of useful light output for rating source lifetimes Like traditional sources LED output degrades over time lumen depreciation and this is the metric for SSL lifetime LED lumen depreciation is affected by numerous environmental conditions such as ambient tempera ture humidity and ventilation Lumen depreciation is also affected by means of control thermal management current levels and a host of other electrical design considerations Color Kinetics systems are expertly engineered to optimize LED life when used under normal operating conditions Lumen depreciation information is based on LED manufacturers source life data as well as other third party testing Low temperatures and controlled effects have a beneficial effect on lumen depreciation Overall system lifetime could vary substantially based on usage and the environment in which the system is installed lemperature and effects will affect lifetime Color Kinetics rates prod
2. For protection from extreme temperatures ColorBlast 12 TR has been designed with a temperature monitoring feature If operating temperatures rise to an unsafe level a compensation circuit is trig gered and the ColorBlast 12 TR operation is interrupted causing the lights to turn dull red After 30 minutes the lights will auto cycle To prevent additional power shut downs determine the cause of the overheating and correct the problem If any problems occur during usage unplug the product immediately and call Color Kinetics Technical Support Group 1 888 FULL RGB or 617 423 9999 or email us technicalsupport colorkinetics com COLORBLAST 12 TR SPECIFICATIONS COLOR RANGE 16 7 million 24 bit additive RGB colors continuously variable intensity output range SOURCE High intensity power light emitting diodes LEDs BEAM ANGLE 23 beam angle frosted 10 clear HOUSING Die Cast Aluminum black PROTECTIVE COVER TPV Elastomer black LENS Soft focus tempered glass or clear tempered glass CONNECTORS 6foot 1 83cm Unified power and data cable with A pin XLR connector LISTINGS UL cUL CE COMMUNICATION SPECIFICATIONS DATA INTERFACE Color Kinetics data interface system CONTROL Color Kinetics controllers or other DMX512 RS485 compatible if using Color Kinetics power data supply ELECTRICAL SPECIFICATIONS POWER REQUIREMENT 24VDC POWER CONSUMPTION 50W Max at full intensity full RGB POWER SUPPLY PDS 750TR ITEM 109 00001 9 00
3. Inc www citytheatrical com for more information on the operating modes CB Mode In CB mode the system will route DMX as Color Kinetics data pro tocol to each output based on the selected DMX starting address Each fixture is set as CK Light 1 DMX 001 002 003 The PDS 750TR s internal DMX Manager selectively routes DMX data to each light output so that each light receives only the data packets that it is supposed to respond to The effective DMX address of each fixture is a function of the starting address of the PDS 750TR combined with the number of the output that the fixture is connected to With the DMX Address set to 001 Fixture 1 DMX 1 2 amp 3 Fixture 2 DMX 4 5 amp 6 etc To put the fixture into CB mode set the DMX Address switches to a desired address other than OOO The fixture can be set fo any valid DMX address however please note that any starting address over 476 will disable some outputs Configuration System Setup for CB Mode DMX Managed To configure the fixture to CB Mode 1 Using the onboard Mini Zapi on the PDS 750TR see City Theatrical PDS 750TR User Guide or the Color Kinetics Zapi see the Zapi User Guide pre address all ColorBlast 12 TR fix tures as DMX 001 2 Plug up to 12 of those ColorBlast 12 TR fixtures into outputs 1 12 one per output 3 Connect the PDS to a DMX source via the DMX In port and con nect power A Set the PDS DMX address to the desired start
4. ColorBlast 12 TR fixtures To change lenses 1 Remove the protective cover from the fixture See Fig 5 CAUTION Do not overload the power data supply Doing so may result in minor or moderate injury or property damage and will void the warranty NOTE Each light must receive power directly from a power data supply You cannot daisy chain power from one ColorBlast 12 TR to another The ColorBlast 12 TR cable contains three color coded wires through a 4 pin XLR connector See Fig 4 e Black GND XLR 4P MALE 5 eevee come aie Qn e Red 24 VDC BN l oe RED Mre PIN 3 DATA WHITE PIN 4 GND BLACK Fig 5 Protective Cover 2 There are two lock down screws located on the fixture sides one per side at the top of the bezel Remove these two screws See Fig 6 Fig 4 L O e B CP SE s PDS 750TR 110 240VAC DMX In Color Kinetics Controller or DMX512 Compatible controller DMX Out for multiple power data supplies Fig 6 we Lock down Screws Bezel LENS REPLACEMENT The ColorBlast 12 TR is designed to allow the user to change between two lens options clear and frosted Both lenses are includ ed with the fixture The clear lens option features a 10 beam angle and is designed for long throw spot lighting applications The frosted lens option provides a 23 beam angle and is design
5. fixture This user guide contains important information about proper installation and safe operation of your new ColorBlast 12 TR light fixture Included in This Box e ColorBlast 12 TR and preassembled base with 6 ft 1 83m 3C 18AWG SJTW Cable and a 4 pin XLR connector e 1 Clear Tempered Glass Lens e 1 Frosted Tempered Glass Lens e Protective Cover e 3 16 Hex Key e User Guide Additional Items Needed e 24VDC power data supply PDS 750TR Item 109 000019 00 e Controller Color Kinetics or DMX compatible Optional Items e 3 16 OD braided safety cable and hardware as required Scope of This User Guide The goal of this user guide is to explain the steps needed to install the ColorBlast 12 TR fixture and assure peak performance Its intended use is for reference only by persons who are fully quali fied This document should never be considered a substitute for any provisions of a regulation or any applicable state or local code Identification and Warnings of Safety Hazards In accordance with ANSI Z535 4 2002 the following system of identifying the severity of the hazards associated with the products is used DANGER mminently hazardous situation which if not avoided will result in death or serious injury WARNING Potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Potentially hazardous situation which if not avoided may result in mino
6. COLORRBLAST 12 TR KINETICS USER GUIDE CHROMACORE BY COLOR KINETICS 10 MILK STREET SUITE 1100 BOSTON MA 02108 USA O N TEL 888 FULL RGB BY COLOR KINETICS TEL 617 423 9999 xe DRY Fax 617 423 9998 INFO COLORKINETICS COM COLOR KINETICS INCORPORATED WWwW COLORKINETICS COM ITEM 116 000019 00 This product is protected by one or more of the following patents U S Patent Nos 6 016 038 6 150 774 and other patents listed at http colorkinetics com patents Other patents pending 2006 Color Kinetics Incorporated All rights reserved Chromacore Chromasic CK the CK logo Color Kinetics the Color Kinetics logo Color Kinetics The Leader in Intelligent Light ColorBlast ColorBlaze ColorBurst ColorCast ColorPlay ColorScape DIMand Direct Light EssentialWhite eW iColor iColor Cove IntelliWhite iW iPlayer Light Without Limits Optibin Powercore QuickPlay Sauce LISTED the Sauce logo and Smartjvice are either registered trademarks or trademarks of Color Kinetics Incorporated in the United States and or other countries 78GF All other brand or product names are trademarks or registered trademarks of their respective owners PUB 000173 00 Rev 00 Specifications subject to change without notice Refer to www colorkinetics com for the most recent version INTRODUCTION Color Kinetics ColorBlast 12 TR offers wall washing wall graz ing and spot lighting in an easy to install
7. cal laws ordi nances regulations and the American National Standard Institute ANSI Safety Code PLANNING THE INSTALLATION The ColorBlast 12 TR installation requires planning to ensure a time ly successful installation with minimal complications and down time Planning Suggestions When planning a ColorBlast 12 TR installation Color Kinetics sug gests doing the following e Consult an Electrical Inspector to review all wiring plans where needed e Refer to local and state codes for installation compliance e Create a Layout Plan drawing e Create a Mapping Grid Use this grid to record serial numbers for easy reference and addressing e Consult Color Kinetics Application Engineering Services as need ed at www colorkinetics com support e Get detailed wiring diagrams and additional support from www colorkinetics com support Installation Considerations e Location of the power data supplies in relationship to lights Each ColorBlast 12 TR comes with a 6 f 1 83m power data cable The power data supply must be located within 60 feet 18 3m of the ColorBlast 12 TR fixtures e Location of the fixture and method of mounting The ColorBlast 12 TR can be installed on a pipe truss or floor Mounting methods vary according to location INSTALLING POWER DATA SUPPLIES The ColorBlast 12 TR can be operated in one of three modes e CB e Pass Thru e Stand Alone Consult the PDS 750TR User Manual from City Theatrical
8. ed for wash lighting appli cations NOTE The bezel pivots at the edge closets to the base It is not necessary to remove the pivot screws 3 Using the tabs on the bezel pivot the bezel forward to access the lens See Fig 6 4 Remove the installed lens and replace it with the desired lens Make sure the gasket around the lens is properly fitted 5 Close the bezel install the lock down screws and replace the protective cover ROUTINE MAINTENANCE Cleaning Use a soft cloth Clean surface with mild soap and water or window cleaner Lubrication As needed apply light household oil to the hinges IMPORTANT INFORMATION Strobe Warning There is anecdotal evidence which suggests that strobe lighting may induce epileptic symptoms in certain susceptible individu als although no associated product warnings have been issued by the United States government according to the Food and Drug Administration If strobe lights are used some international regulatory agencies recommend keeping flicker rates at or below four flashes per sec ond as less of the flicker sensitive population will then be at risk of an attack This flicker rate applies only to the overall output of any group of lights in direct view However when more than one strobe light is used the flashes should be synchronized End users should also consider issuing a warning alerting audience or viewers to the presence of strobe lighting Temperature Monitoring
9. ing address value AAA 5 The 12 connected ColorBlast 12 TR fixtures will respond as fol lows Fixture 1 DMX address AAA AAA 1 AAA 2 Fixture 2 DMX address AAA 3 AAA 4 AAA 5 Fixture 3 DMX address AAA 6 AAA 7 AAA 8 etc Pass Thru Mode In Pass Thru mode the system will convert all the DMX values to Color Kinetics data protocol and send that CK data with 24V power to all 12 ColorBlast 12 TR outputs The Pass Thru mode is used for ColorBlast 12 TR fixtures powered by the PDS 750TR in a system requiring Zapi addressing schemes such as when being used in combination with other Color Kinetics power supplies like the PDS 150 Pass Thru mode is selected whenever the DMX Address switches are set to all zeros 000 and the Config switch is set to O Stand Alone Effects Mode In Stand Alone mode the PDS 750TR will run various preprogrammed effects without a console This is very useful for events like parties or trade shows where a constantly running program is desired without the use of a console or show program ming The unit is placed into Stand Alone mode using the Config BCD switch When the unit is in Stand Alone mode the DMX Address switches become Effects controls Different Stand Alone Effects are selected via different setting combinations of the DMX Address switches and the Config switch INSTALLING THE FIXTURES DANGER Ensure that main power supply is off before installing or wiring the ColorBlast 12 TR a
10. nd power data supply Failure to adhere to these instructions will result in death or serious injury and will void the warranty WARNING The ColorBlast 12 TR and the power data supply must be installed by a qualified professional in accordance with NEC and relevant local codes Failure to comply could result in death or serious injury and will void the warranty Connecting ColorBlast 12 TR Fixtures to the PDS 750TR The PDS 750TR is provided with a female 4 pin XLR connectors for output connections to the ColorBlast 12 TR fixtures The connector pinout is as follows PIN Signal CK Cable Wire Color 24 vyDC Red S a a S Color Kinetics ColorBlast 12 TR fixtures are provided with a per manently connected 6 ft 1 83m cable The maximum distance between the PDS 750TR and the ColorBlast 12 TR can be 60 ft 18 3m Pipe Truss Mount The ColorBlast 12 TR can be mounted fo a pipe or truss using a standard theatrical C clamp The ColorBlast 12 TR is provided with a clearance hole for a 1 2 bolt on the mounting base for attaching C clamps When mounting the ColorBlast 12 TR in this way all nec essary care should be taken to ensure that the installation is suitable and safe and that the hardware is properly rated for the task See Fig 1 Fig 1 eae ERES BoBsVaBSO SSS S Floor Mount When mounting the ColorBlast 12 TR on the floor ensure that the fixture sits flush to the surface and u
11. r or moderate injury or property dam age Also used to alert against unsafe practices IGNORING A HAZARD WILL VOID ANY WARRANTY DANGER Ensure that the main power supply is off before installing or wiring the ColorBlast 12 TR and power data supply WARNING The ColorBlast 12 TR and power data supply must be installed by a qualified professional in accordance with NEC and relevant local codes WARNING Do not attempt fo install or use the ColorBlast 12 TR or power data supply until you read and understand the installation instructions and safety labels CAUTION The ColorBlast 12 TR has no serviceable electronic parts Do not attempt to service the fixture CAUTION Do not modify alter or attempt to service the ColorBlast 12 TR CAUTION You must use the cable provided with the unit CAUTION Do not use sharp fools near or on the fixture lens CAUTION Do not hot swap Ensure the power supply is off before connecting or disconnecting fixtures CAUTION Do not overload the power data supply NOTE The instructions and precautions set forth in this installation guide are not necessarily all inclusive all conceivable or relevant to all applications as Color Kinetics cannot anticipate all conceivable or unique situations Owner User Responsibilities It is the responsibility of the contractor installer purchaser owner and user to install maintain and operate the ColorBlast 12 TR in such a manner as to comply with all state and lo
12. se mounting hardware suitable for the mounting surface See Fig 2 Fig 2 Aim fixture and lock in place FRONT VIEW Attaching the Safety Cable Each fixture is designed for use with a safety cable When required by local or state code or by a Structural Engineer attach a safety cable from the fixture to the mounting surface 1 Locate the safety cable bracket on rear of the ColorBlast 12 TR See Fig 3 Fig 3 END USER SPECIFIES REQUIRED END TERMINATOR AND ANCHORING 2 Attach the safety cable to the mounting surface Consult a Structural Engineer and refer to applicable standards for your specific application to determine the proper method for mounting the safety cable to the installation surface Safety cables used in the installation must meet the following minimal requirements MATERIAL 316 Stainless Steel SIZE 5 64 inch 0 78 inch nominal diameter or larger minimum break load must be greater than 400 pounds Maximum diam eter is 3 16 inch CONSTRUCTION 7 x 7 49 wires preformed stranded END TERMINATIONS Determined by installer and or owner MOUNTING METHOD Determined by installer or owner Making Electrical Connections ColorBlast 12 TR is compatible with Color Kinetics PDS 750TR power data supplies Connecting Power ColorBlast 12 TR a 24VDC After installing the i fixtures connect the power data cable to the power data supply The PDS 750TR supports 12
13. uct lifetime using lumen deprecia tion to 50 of original light output When the fixture is running at room temperature using a color wash effect the lifetime is in the range of 80 000 100 000 hours This is based on LED manufactur ers test data High output is defined as any LED device that is 1 2 watt or above For more detailed information on source life please see www colorkinetics com lifetime WARRANTY This product is sold pursuant to CK s Standard Terms and Conditions the T amp Cs which may be found at http colorkinetics com howtobuy buy terms and which contain important provisions including among others Limited Warranty exclusions and limitations on CK s liability for damages and restrictions on the remedies that are available to you 1 Guide to Health Safety and Welfare at Pop Concerts and Similar Events HMSO Publications UK