Home

601-262B - INA 6501_INA 6502 User Manual english.indd

image

Contents

1. MANUAL amp AUTOMATED STEP TRANSFORMER INA 6501 6502 USER MANUAL 601 262B JJ Advanced Test Solutions for EMC MANUAL amp AUTOMATED STEP TRANSFORMER INA 6501 INA 6502 USER MANUAL CONTENTS 1 1 1 2 1 2 1 1 3 2 1 2 2 2 2 1 2 3 Manual step transformer INA 6501 C In O ircuit diagram INA 6501 Technical specifications INA 6501 Parts description stallation connection to NSG Automated step transformer INA 6502 ircuit diagram INA 6502 Technical specifications INA 6502 Parts description Installation connection NSG of CDN Addresses 1 MANUAL STEP TRANSFORMER INA 6501 mmm The manual step transformer type INA 6501 is a standard accessory for the Teseq NSG 3000 instrumentation series It provides a convenient means for reducing the incoming supply voltage by pre set amounts It is required for power quality testing PQT and is fully compliant with the latest revisions of IEC 61000 4 11 2004 It is fitted with carrying handles as part of its overall good ergonomic design which makes for ease of handling Further the unit may be used in any of three operating positions laying or standing on a work bench or for more permanent applications it can be wall mounted Care has to be taken in case of use in standing position EE as the stability is limited The cabling connecting INA 6501 to mains and NSG presents a risk of being unvol untarly caught by the users which could cau
2. switch Front panel switch with on indicator 16 A slow blow Harting type HAN3A compatible with NSG safe linking concept Manual amp automated step transformer INA 6501 INA 6502 Size Weight Cable length to NSG Input cable 1 2 1 Parts description Part designation EUT power in switch 16 AT fuse EUT power in plug EUT power out cable Red selector 150 x 180 x 360 mm 12 kg approx 2m NSG standard cable to be used Function Switches on off the EUT power supply Protects the EUT power supply line This is where the EUT power needs to be applied use NSG supplied cable and conect it to power source mains Connect this cable to the EUT supply input port of NSG To switch variable voltage to O or 40 or 70 or 8096 of Uin 1 3 Installation connection to NSG tion and interconnection d The equipment should be switched off during installa B Connect INA 6501 EUT power out to NSG EUT power input B Connect INA 6501 EUT power in to mains using EUT power in cable delivered with NSG TASEO Advanced Test Solutions for EMC Because of the capacitors in the internal coupler of CDN d earth leakage currents of up to 4 A can occur in the EUT power supply network The test system must therefore be correctly earthed and be powered from a supply that is not protected by a residual current detector RCD BW Switch on EUT power on INA 6501 red switch when power for the EUT is required B Switch on the
3. 00 software Manual amp automated step transformer INA 6501 INA 6502 EUT power on off function Fuse Connectors Possible extensions Own supply Size Weight Cable length to Modula Input cable Control cable included in delivery 2 2 1 Parts description Part designation Mains supply in socket EUT power in switch 16 AT fuse EUT power in plug EUT power out cable W Front panel switch with on indicator 11 16 A Slow blow Harting type HAN3A compatible with NSG safe linking concept W Connection to remote EUT power on off switch INA 6581 B Interlock connection to door switch Selectable 100 110 V 220 240 V 15 VA 460 x 200 x 160 mm 15 kg approx 2m NSG standard cable to be used 2m 25 way sub D twisted pair shielded Function For instrument supply includes plug voltage selector 110 V 230 VAC on off switch and fuse Switches the EUT power supply on off Protects the EUT power supply line For feeding of the EUT power use NSG supplied cable and connect it to power source mains Connect this cable to the EUT supply input port of the NSG TASEO Advanced Test Solutions for EMC 12 Part designation Plug X3 Plug X2 Plug X1 Power LED green Error LED off ERROR LED blinking ERROR LED on Function Remote TEST and EUT power off with shorting plug Allows to conect external door switch or equivalent e g INA 6581 Interrupts the 24 V supply of the circuit breaker c
4. 33 139 47 42 21 F 33 139 47 4092 francesales Q teseq com Japan Teseq K K T 81 3 5725 9460 F 48135725 9461 japansales Qt eseq com Switzerland Teseq AG T 41 32 681 40 50 F 41 32 681 40 48 sales teseq com UK Teseq Ltd T 44 845 074 0660 F 44 845 074 0656 uksales teseq com December 2010 Teseq Specifi cations subject to change without notice Teseq is an ISO registered company Its products are design ed and manufactured under the strict quality and environmental requirements of the ISO 9001 This document has been carefully checked However Teseq does not assume any liability for errors or inaccuracies
5. INA 6502 EUT power out to EUT power input Connect INA 6502 EUT power in to mains using EUT power in cable delivered with NSG or CDN s EEEE Because of the capacitors in the internal coupler of ET CDN earth leakage currents of up to 4 A can occur in the EUT power supply network The test system must therefore be correctly earthed and be powered from a supply that is not protected by a residual current detec tor RCD w BW Switch on INA 6502 first BW Switch on NSG CDN mainframe BW Switch on EUT power red switch when power for the EUT is required TASEO Advanced Test Solutions for EMC Headquarters Teseq AG 4542 Luterbach Switzerland T 41 32 681 40 40 F 41 32 681 40 48 sales teseq com www teseq com China Teseq Company Limited T 86 10 8460 8080 F 86 10 8460 8078 chinasales teseq com Germany Teseq GmbH T 49 30 5659 8835 F 49 30 5659 8834 desales Oteseg com Singapore Teseq Pte Ltd T 65 6846 2488 F 65 6841 4282 singaporesales Qteseq com Taiwan Teseq Ltd T 4 886 2 2917 8080 F 886 2 2917 2626 taiwansales Q teseq com USA Teseq Inc T 1 732 417 0501 F 1 732 417 0511 Toll free 1 888 417 0501 usasales teseq com To find your local partner within Teseq s global network please go to www teseq com Manufacturer Teseq AG 4542 Luterbach Switzerland T 41 32 681 40 40 F 41 32 681 40 48 sales teseq com France Teseq Sarl T
6. NSG generator B Select the required variable voltage using rotary switch on the INA 6501 Manual amp automated step transformer INA 6501 INA 6502 2 AUTOMATED STEP TRANSFORMER INA 6502 mem The automated step transformer type INA 6502 is a standard accessory for the Teseq NSG 3000 instrumentation series It provides a convenient means of reduc ingthe incoming supply voltage by pre set amounts It is required for power quality testing PQT and is fully compliant with the latest revision of IEC 61000 4 11 2004 Its control is fully automatic driven from NSG master controller using the inter face or WIN 3000 software Once detected the functions offered by INA 6502 are available in the interface or software So the settings O 40 70 80 will appear as well as the possibility to switch EUT power on off INA 6502 comes fitted with carrying handles as part of it s overall good ergo nomic design which makes for ease of handling Further the unit may be used in any of two operating positions laying on a work bench or for more perma nent applications it can be wall mounted The unit has been designed for use in rugged industrial environments Profes Sional quality connectors ensure user safety additional system protection is provided by a 16 A fuse located in the top panel Thanks to the provision of an 8096 voltage position and to the large over current capabilities the step transformer is fully compliant with the latest requ
7. irements called for in IEC 61000 4 11 2004 standard nisms it is strongly recommended to power on first the INA For proper operation of the plug and play detection mecha 6502 accessory and then the NSG main frame TASEO Advanced Test Solutions for EMC 9 10 2 1 Circuit diagram INA 6502 EUT Power ON OFF Circuit Breaker Option CIB L 4 A Uin i mE E E NI 16 A A Uvar Eur NC dod Power moot i Po oaa N PE i qe Hof i PE as ot ob 1 a aa Power i o cH q N A y M 0 40 70 80 EUT Power jo lt ON OFF ij Supply mg Interface Controller a Remote Test EUT Plug XI System cable IN Plug X2 System cable OUT Power OFF 25 Way Sub D Male 25 Way Sub D Female Connection to NSG Termination with MaterController via Interlock plug System Interface cable 2 2 Technical specifications INA 6502 Input voltage Output voltage Accuracy Voltage change with load 10096 output O to 16 A 8096 output 0 to 20 A 7096 output 0 to 23 A 4096 output O to 40A Output current capability at 230 V input voltage Voltage selection Oto 250 VAC not suited for DC voltages 4 steps O 4096 70 8096 x 596 less than 596 less than 596 less than 596 less than 596 16 Arms at 10096 output 20 Arms at 8096 output 23 Arms at 7096 output 40 Arms at 4096 output User interface or WIN 30
8. ontactor which switches EUT supply on off The information will be transmitted to NSG master controller which will stop the test NSG system interface out to be termi nated by interlock plug or linked to another accessory to X1 plug NSG system interface in to be con nected to master controller or to another accessory to X2 plug Shows if instrument is powered up No problem acessory is ready to run Problem which may be solved by user intervention Expl Interlock is activated emergency button is pressed Problem which needs module repair please ntact your nearest Teseq customer support center or sales reprsentative 2 3 Installation connection to NSG or CDN tion and interconnection m The equipment should be switched off during installa Manual amp automated step transformer INA 6501 INA 6502 EUT power On Off switch 16 AT fuse 13 Mains power switch E It E Mains power e p e EUT power out to NSG or CDN LED indications m Termination plug System cable to to NSG or CDN A EUT power in connection E Verify the setting of input voltage selector and adjust it to the right mains voltage value if required Connect instrument power from the mains Remove 25 way Sub D plug at rear of NSG or CDN Connect this connector to X2 of INA 6502 Connect master controller 25 way output to INA 6502 X1 plug using system interface cable delivered with INA 6502 Connect
9. se the INA 6501 to fall down The few control elements are readily accessible on the front panel An EUT power on off switch with a power on indicator and a well proportioned rotary Switch to select the required voltage ensure easy and intuitive operation The unit has been designed for use in rugged industrial environments Professional quality connectors ensure user safety additional system protection is provided by a 16 A fuse located in the front panel Thanks to the provision of an 8096 voltage position and to the large overcurrent capabilities the step transformer is fully compliant with the latest requirements called for in IEC 61000 4 11 2004 standard TASEO Advanced Test Solutions for EMC 1 1 Circuit diagram INA 6501 F1 S1 L 1black 2 1 E 2 blue a Ye Gr INA 6501 Step transformer i black 3 L brown 3 L var 096 blue 2 N 1 2 Technical specifications INA 6501 Input voltage Output voltage Accuracy Voltage change with load 10096 output O to 16 A 8096 output 0 to 20 A 7096 output 0 to 23 A 4096 output O to 40A Output current capability at 230 V input voltage Voltage selection EUT power on off function Fuse Connectors Oto 250 VAC not suited for DC voltages 4 steps O 4096 70 8096 5 less than 5 less than 5 less than 5 less than 5 16 Arms at 100 output 20 Arms at 80 output 23 Arms at 70 output 40 Arms at 40 output Front panel rotary