1. Table 3 Alcolizer Technology LE5 Specifications Table 4 Event Log description arrarnarnnrrnrrnerrarrarnnrnnnnnnnnenneener Page 4 of 43 Alcolizer LE5 User Manual V1 2 SA lcolizer Alcolizer LE5 User Manual technology REFERENCE DOCUMENTS sm CHANGE STATUS Initial Issue 1 Jun 2014 General Manager New Template 20 Jan 2015 National Service Manager Revised template Mar 2015 General Manager Page 5 of 43 V1 2 Alcolize f Alcolizer LE5 User Manual technology 1 INTRODUCTION This User Manual details the operation of the Alcolizer LE5 alcohol breath testing device and Alcoconnect software for managing and analysing breath test results This User Manual is divided into various Sections and Sub sections to enable the user to access the required information with ease It includes Cautions and Notes applicable to the LES device and a opecifications table NOTE This User manual is applicable to the Alcolizer LES version SSMAPP installed with firmware version 1 26 and later 2 DESCRIPTION OF LE5 2 1 Equipment Overview The LES Equipment List includes the following items e LE5 handheld device Li ION powered or AA Alkaline battery powered e USB cable e Battery Chargers 240VAC and 12VDC vehicle Li ION version only e User Manual and Alcoconnect CD e Silicon protective cover optional and wrist strap e Carry ba
2. Print Last displayed Figure 48 Print Record displayed eseeeeessesss Figure 49 Area Code displayed eeseeeeeeeeeeses Figure 50 Area Code Set rrrararnnnrnannnnrnanrnernnnnnennnnnnrnnennannnnnnn Figure 51 Records displayed eessessesss Figure 52 Memory capacity warnings eeeeeeeeeeeeee Figure 53 Days to calibration displayed Figure 54 Recalibration Due Now message Figure 55 Replacing a sample module Figure 56 AutoPlay WINKOW cccccccecceeceeeeeeeeeeeeeeeeeeseeeeeeeees gor DI FESIS qM V m Figure 58 Alcoconnect Setup window eseesses Figure 59 Setup Successful rrarrnarnnnrnannnnrnannnnrnannnnrnnnnnnrnnnenn Figure 60 Read Event Log Window eeeeeeeeeesse Figure 61 Event LOQ cccccccccecceeceeseeseeceecaeceeeceeeeeseeseesensaees Figure 62 Log Settings window cccccceccsecceeeseeseeeeeeeeeeaeeees LIST OF TABLES Table 1 GPS mode Configurations cccceceeecseeeeeeeeeeeeseeeeeees Table 2 Printer pin length displayed
3. Bixolon SPP R200 Figure 39 C Bixolon SPP R200 gt Printer Driver A Connect Mode Auto Send Standard Auto Send Passive Auto Print Standard Auto Print Passive Printer Driver T Figure 39 Printer brand and type displayed Once the LE5 device is paired with the printer the Bluetooth icon is visible on the screen at all times refer Figure 40 201415 eS a Figure 40 Bluetooth icon on screen 6 3 Connect Mode There are two Connect modes for the printing function on the LE5 On Demand and Permanent 6 3 1 On Demand On Demand Connect mode is only used when printing is required on an ad hoc basis and not after every test To activate On Demand Connect mode proceed as follows a Establish Bluetooth communications with the printer in accordance with the procedures at paragraph 6 1 a to 6 1 g b Scroll down until Connect Mode is highlighted refer Figure 41 Page 28 of 43 V1 2 Alcolizer Alcolizer LE5 User Manual technology 16 01 9015 NR 46 gt On Demand Printer Pairing Edit RiueTnnth PIN Connect Mode Auto gt end Standard Auto Send Passive Auto Print Standard Auto Print Passive Figure 41 Setting Connect Mode C On Demand is highlighted as the default setting 6 3 2 Permanent Permanent Connect mode is used when the results of every test are to be printed To activate Permanent Connect mode proceed as follows a Perform the procedures at paragr
4. d Ask the Subject to start counting from 20 onwards a one second rhythm until you tell them to stop 20 21 22 23 24 25 etc e Press the Test button while subject is counting The device will make a series of clicking sounds as the sample is being taken The device is set to take three pump samples During these three pumps the operator must hold the device steady and at the same distance from the subject The device will give three sample pump clicks followed by a long beep sound Analysing Sample will then be displayed refer Figure 13 3 6 7 Analysing a Passive Breath Sample After a valid breath sample is taken the Analysing Sample message is displayed until the device determines if alcohol is present This will normally take a few seconds In cold climate conditions it may take longer to display the result When the Passive standard reading is calculated it will be displayed and retained until the Recovering period has ended If a Pass No Alcohol reading is displayed the device has indicated that no alcohol was detected in the near vicinity of subject s exhaled breath When the Recovering period has ended the device is ready for next Passive standard breath test refer Figure 19 15 08 2014 12 56 e um Figure 19 Pass No Alcohol message To perform another Passive standard breath test repeat steps in paragraph 3 6 4 If a Warning Alcohol Present reading is displayed the device has indicated that
5. The GPS position fix will then be logged with the test reading refer Figure 31 20 10 2014 14 54 e Ol Record ID223 2010 2014 14 57 46 Standard Breath Test a 105m 577 53159 E153 26520 Scroll Records Y Figure 31 GPS Position displayed in Records If there is no location fix then Location Unknown is logged against the test reading The default time for locating a GPS position fix is set to 120 seconds If a GPS fix is not located within this period then Location Unknown is recorded Page 24 of 43 V1 2 Alcolize f Alcolizer LE5 User Manual technology NOTE If the device is configured to record a GPS fix for positive test readings then a GPS fix operation will only occur when a reading is above zero BAC 6 SENDING AND PRINTING DATA The printing function if installed enables the printing of records by connecting the LE5 to a portable printer via Bluetooth connection The device supports the following printers e Axiohm A631 e SPRT SP T5 e SPRT SP T7 e Custom S Print e Custom MYPrinter e Bixolon SPP R200 e Zicox HDM322 NOTE For information on operating the printer refer to the appropriate printer User Manual 6 1 Bluetooth Connection In order to establish the connection with the printer via Bluetooth access to the device set up menu is required Establish Bluetooth connectivity as follows a b Switch the LE5 device on refer paragraph 3 6 With the screen
6. 11 Figure 6 Press to test MESSAGE ccccccecceecceeceeceeceeceesecaeeceeceeseeseesuesuesaesaueceeceeseesensansass 12 Figure 7 Locating the Mouthpiece ccc ccc secs eeceeceece eee eeeeeeeeseeseceeeeeeseeaeeaeeseeseeseeeeeeaes 13 Figure 8 Mouthpiece correctly positioned rrarrarnarnnrrnernarnarvnrnnnnnnrnernernernarnannnannannennennennen 13 Figure 9 Blow is displayed when device is FEACY ccccccececceeceeceeeeeeeeseeseeseeceeseeeeeaeeaes 14 Figure 10 Providing a SAMPIEC ccccceccccceecceeceeceeceeceecaecaecaeeceeceeseesuesaesaesaeeceeseesensensansass 14 Figure TT Sample progress DO Ne 14 Figure 12 Invalid Sample try Again message arrrnrnannnnrnanrnarnnnnnannnnrnannnnnnannnnnnannnennennennenn 15 Figure 13 Analysing sample message sssessssssesssseeneennene nennen nennen nnn nens 15 Figure 14 Various BAC and screen colours displayed ccccceecceeceeeeeeeeeeeeeeeeeeeeeeeeeaeees 16 Figure 15 Test Type displayed ee 16 Figure 16 Passive Standard displayed ccccccceccceeceeeceeeeeeeeeeeeeseeeeeeseeeeeeseeeeeeseeseeseees 17 Figure 17 Ready for passive test message sssssssssssssessseeeeeee nenne nennen nnns 17 Figure 18 Providing a Passive sample cece ccc cecceeceece eee eeeeeseeseeceeceeeeeeaeeseeaeeseeseeseeeeeeaes 18 Figure 19 Pass No Alcohol message ccc eeceecc
7. Alcolizer Alcolizer LE5 User Manual technology ALCOLIZER LES USER MANUAL Disclaimer External Documents Note to Reader The BAC reading obtained by correct use of this device is only considered accurate at the time of testing Great care has been taken to ensure the accuracy of each reading Neither the manufacturer the distributor nor the owner accepts liability or responsibility due to any action or claim arising from the reading produced by this device whether used correctly or incorrectly Alcolizer Technology 2015 V1 2 SA lcolizer Alcolizer LE5 User Manual technology TABLE OF CONTENTS T INTRODUC TON icseuziecz susce uaes Uv uus E E 6 2 DESCRIPTION OF LES eranrnnvnnvnvnnvnnvnvnnvnnvnvvavnnvnnvarnnvnnvarnavnnvnnvavnnvnnvavnnvnnvavnnvnnvnnnnvnnvnnnn 6 2 1 Equipment Overview rrarrnrnnrrnrnurnnrnarnnnnnnrnernernernnrnnsnnsnnnnnennennennuenuennannnnnnnnennenneene 6 22 Device OVErIEN Le eee ede taedas he tele tel CEARA nanaonan nenna nae 6 3 OPERATING INSTRUCTIONS rannnrnnvnvnvnnvnvnnnnvnvnnnnvnnnnvnnnnvnvnnvnvnnvnvnvnnvnvnnvnvnnunvnvnnvavneunve 8 3 1 General Information 0 cccccceccccccccccccccccececccacececneaceeenecceaecnesueaeenesneceenteneaneass 9 3 2 Testing Types rrornrrnnrannarnarnernarnnnarnarnarnennarnanarnurnennannannenunnarnennnnnannenuenennannennsneee 9 gt 5 10000610 110 oe EEE EEE 9 3 4 Charging the Battery Li ION powered device rrarnarnnrnnrrnnr
8. Event Log icon and The Event Log will then be displayed refer Figure 3 2 1 Serial Number ai Main Se al No Sample Serial No 2542095 2640000 6 Date amp Time anomuzorem Lid k 1 20 10 2014 252 PM 2 527 53159 8 z 20 10 2014 2 47 PM 20 10 2014 246 PM 20 10 2014 2 45 PM 192753157 20 10 2014 2 39 PM 27 531 18 20 10 2014 1 59 PM s2753127 20 10 2014 1 54 PM 20 10 2014 143 PM 20 10 2014 1 46 PM 4 20 10 2014 1 33 PM 20 10 2014 1 32 PM i 20 10 2014 1 30 PM 16 09 2014 3 49 PM 16 09 2014 2 54 PM 16 09 2014 253 PM 16 09 2014 2 47 PM Revision 1 26 Units g 100ml Records 232 Version 1 01 Figure 61 Event Log Page 41 of 43 V1 2 Alcolizer Alcolizer LE5 User Manual technology 11 2 1 Navigating around the Event Log page Refer to Table 4 and Figure 61 for a description of the Event Log page Table 4 Event Log description Figure Icon Button or Deception Reference Heading P Road Even deg Select to download records from the LE5 Select for Save Event Log save as a csv or xml file to a file location in computer or elsewhere 2 File icon Language Choose a language if the LE5 is configured for multiple languages Options Set Log Settings Refer to paragraph 11 2 2 fora description of Log Settings Activates the Event Log application Same fun
9. alcohol was detected in the near vicinity of subject s exhaled breath refer Figure 20 Page 18 of 43 V1 2 Alcolize f Alcolizer LE5 User Manual technology Figure 20 Warning Alcohol Present message After the recovery period has ended the device is enabled automatically to take an Active Mouthpiece sample refer Figure 21 Perform an Active test in accordance with the procedures in paragraph 3 6 1 000 01 06 14 02 e uu EE A a rios 9 for active test Figure 21 Warning Alcohol Present Press for Active Test display 3 6 8 Enabling Passive Only To enable Passive Only perform the same steps as in paragraph 3 6 5 with the exception of step 3 6 5 c Press the Test key until Passive Only is displayed NOTE A Passive Only test will not automatically enable an Active Mouthpiece test the same way a Passive Standard test does 3 6 9 Taking a Passive Only Breath Sample The procedures for performing a Passive Only test are the same as those for performing a Passive Standard test refer paragraph 3 6 6 NOTE When a Warning Alcohol Present reading is displayed after performing a Passive Only test it is strongly recommended that a Mouthpiece Breath Test be performed after the recovery period has ended refer paragraph 3 6 2 Page 19 of 43 V1 2 Alcolizer Alcolizer LE5 User Manual technology 3 Back operation The user menus include a Back selection which when selected will return
10. from the main module Figure 55 Replacing a sample module Following the replacement of the sample module send the out of cal module back to Alcolizer The device can be returned to Alcolizer Technology for calibration should the owner prefer prior to the number of days warning message period expiring To arrange calibration contact Alcolizer Technology by any of the following means a Phone 1300 789 908 b Email sales alcolizer com or e Web www alcolizer com 10 SPECIFICATIONS The technical specifications of the LE5 are detailed in Table 3 Table 3 Alcolizer Technology LE5 Specifications Instantaneous for 0 0000 BAC readings reading remains on screen for 5 seconds Standard spigot locator or non return mouthpiece Not Mouthpiece Type required for Passive testing Recovery Time Sensor Type 0000000000 Sensor Type 0000000000 Electro chemical fuel cell premium grade platinum Rechargeable Li ION battery or AA Alkaline disposable Power SUPPIY batteries Page 38 of 43 V1 2 Alcolize f Alcolizer LE5 User Manual technology Weight 2 2 grams Dimensions 202mm H x 63mm W x 39mm D Calibration Six monthly recalibration at Alcolizer Technology s service facility 11 ALCOCONNECT Alcoconnect assist in the analysis of data downloaded from the LE5 device The Alcoconnect software can be loaded from the supplied CD onto a compatible computer running MS Windows XP Vista Win 7 or Win 8 1
11. to the previous screen To select Back proceed as follows a Press the Up down buttons until Back is highlighted refer Figure 22 24 10 2014 10 39 e ui Test Type Print Last Print Record Records About Off 4 Back Figure 22 Screen Back selection b Press the Test key The display will return to the previous screen 3 8 Shutting Down The LES will automatically shut down after a period of inactivity Should the device be required to be shut down manually e g to conserve battery life perform the following procedures a With the screen displaying press to test Press the Up and Down buttons simultaneously The User Menu will be displayed refer Figure 15 b Using the down button scroll down to off refer Figure 23 16 09 2014 13 50 lt gt rum A Test Type Print Last Print Record di dm ll ui Khe Ahnit EG 4 back Figure 23 Off displayed C Press the Test key The device will turn off To further conserve battery life the device will automatically switch off the display back light after two minutes To re activate the device following back light power down Press the Test key or Up down buttons The device will display the last screen that was activated at the time the back light switched off Page 20 of 43 V1 2 Alcolizer LE5 User Manual Alcolizer technology 4 TEST OPTIONS MENU 4 1 Test Cancel If the user wishes to cancel a test perform the follow
12. 1 1 Installing Alcoconnect Software Unless otherwise specified the software will reside on the computer s C drive NOTE The procedures stated here apply to an installation on a computer equipped with MS Windows 7 For other operating systems refer to the appropriate User Manuals for direction if installation difficulties are encountered To install the Alcoconnect software proceed as follows a Load the Alcoconnect CD into the DVD drive of the computer The AutoPlay window will appear refer Figure 56 az AutoPlay amp DVD RW Drive D LES Gam Alcoconnect Always do this for pictures Pictures options sad Import pictures and videos ON using v General options ib Open folder to view files S View more AutoPlay options in Control Panel Figure 56 AutoPlay window b Select the Open folder to view files option and click The files on the CD will be listed refer Figure 56 C Click on the Setup option refer Figure 57 The Alcoconnect Setup window will appear Page 39 of 43 V1 2 Alcolizer Alcolizer LE5 User Manual technology E e Computer DVD RW Drive D LES Alcoconnect Alcoconnect Organize v Burn to disc Delete temporary files Name Jr Favorites BE Desktop JA Downloads Recent Places Date modified 4 Files Currently on the Disc 3 9 Applnstall 2 07 2014 10 59 AM M Windows Installer IE E dotNetFx40 Full x86 x64 1 07 2014 11 44 AM Applic
13. All regardless of results a complete report including time location lat long if GPS enabled test type result etc will be transmitted To set the LE5 to Auto Send Standard scroll down until Auto Send Standard is highlighted Positive is the default option To select A or None press the Test key until the desired option is highlighted refer Figure 43 16 04 9045 09 51 e P 58 01 2015 09 52 lt gt Gof 6 01 0015 09 57 gt iin uta Send Standard Printer Pairing Printer Pairing Printer Pairing Edit BlueTooth PIN Edit BlueTooth PIN Edit BlueTooth PIN Connect moug Connect Mode Connect Mode Auto Send Standard Auto Send Standard Auto Seno Fassive Auto Send Passive Auto Send Passive Auto Print Standard Auto Print Standard Auto Print Standard Auto Print Passive Auto Print Passive Auto Print Passive T v Figure 43 Auto Send Standard with the three options 6 4 2 Auto Send Passive Auto Send Passive applies only to Passive testing Depending on the Auto Send Passive option selected the information may be transmitted following the various tests except None The result will be either false if no alcohol is detected or true if alcohol is detected per the following explanations e Positive if alcohol is detected A short report including time device information test type etc will be transmitted e All if alcohol is either detected or not a short report including time device information test type etc will be
14. IN Page 32 of 43 V1 2 Alcolizer Alcolizer LE5 User Manual technology e Using the Up down buttons select the PIN length that applies to the printer e g for the Bixolon SPP R200 select 4 f Use the Up or Down buttons to display the first number of the PIN e g O Press the Test key to advance to the next number and repeat step f Repeat steps g and f until all numbers are displayed as required by the printer refer Figure 46 22 10 2014 15 3 lt lt Gil 0000 Enter pin Printer Pairing C Edit BlueTooth PIN Connect moge Auto Send Standard Auto Send Passive Auto Print Standard Auto Print Passive Y Figure 46 PINs entered l Press the Test key The PIN is now set 6 Printing records 6 7 1 Automatic printing Once the LE5 and printer are paired turned on and within Bluetooth range the printer will automatically print a record of the breath sample at the time of the test 6 7 2 Printing records To print the last breath test perform the following procedures a With the screen displaying press to test press the Up and Down buttons simultaneously The User Menu will be displayed refer Figure 15 b Press the Down button and scroll to Print Last refer Figure 47 23 10 2014 09 4 lt gt Gili Print Last GPS Area Code T act Timo fae Toss E Frint Last Print Record Records About Y Page 33 of 43 V1 2 SA lcolizer Alcolizer LE5 User Manual technology Figu
15. Pairing Edit BlueTooth PIN Connect Mode Auto Send Standard Auto Send Passive Auto Print Standard Auto Print Passive v Figure 36 Searching displayed Page 26 of 43 V1 2 Alcolizer Alcolizer LE5 User Manual technology NOTE The LE5 will search and display all Bluetooth devices in range To avoid attempting to connect to a device other than the intended printer move other Bluetooth items away When the LE5 identifies the printer the printer type will be displayed E g SPP R200 refer Figure 37 2910 2014 13 47 e I i sim a TITTI T Bile 4 Hack Figure 37 Printer identified j Press the Test key to accept the selected printer 6 2 Printer driver 6 2 10 Installing the printer driver To install the printer driver proceed as follows a Access the printer menu as described in paragraphs 6 1 a to 6 1 g b Press the Down button and scroll down to Printer Driver refer Figure 38 22 10 2014 14 32 lt gt Gil No Printer Printer Driver Connect Mode Auto Send Standard Auto Send Passive Auto Print Standard Auton Print Passive C Printer Driver YT Figure 38 Printer Driver displayed C Press the Test key d Press the Down button and scroll down to the printer brand and type e g Bixolon SPP R200 Page 27 of 43 V1 2 Alcolizer Alcolizer LE5 User Manual technology e Press the Test key The printer brand and type will be displayed on the screen e g
16. Print Record Records About v Figure 16 Passive Standard displayed d Press the Up and Down buttons simultaneously Passive Standard is now enabled or press the Down button until Back is highlighted then press the Test key to leave the User Menu 3 6 6 Taking a Passive Standard Breath Sample NOTE If any step in a breath test sequence is not completed or the device is left idle for a prolonged period of time then the device will terminate the breath test and display Test timed out the device will return to the press passive test display The standard breath test time out period is 60 seconds If a test time out does occur during a breath test a new breath test must be performed Press the Test key to perform a new passive breath test as per steps above Perform a Passive Standard test as follows a On the press passive test page press the Test key Ready for passive Test is displayed refer Figure 17 15 09 2014 12 49 e rum Ready for passive Test Figure 17 Ready for passive test message b Press the Test button The device will perform a self test and then return to Ready for passive Test Page 17 of 43 V1 2 Alcolizer Alcolizer LE5 User Manual technology C Hold the device no further than 100mm in front of the test subjects mouth so that the subject is breathing or talking directly into the device s sample inlet port refer Figure 18 Figure 18 Providing a Passive sample
17. a Code Test Type Print Last Print Record ds v Figure 29 GPS position on Menu Screen 5 2 GPS Mode configuration Refer to Table 1 for GPS mode configuration Table 1 GPS mode configurations Positive Tests Positive Tests All tests All tests Threshold Threshold of Page 23 of 43 V1 2 SA lcolizer Alcolizer LE5 User Manual technology 5 3 Static GPS Mode Operations The Static GPS Mode Operations if enabled will initiate a once only GPS position fix before a Standard Active Breath Test The same GPS position fix or Location Unknown will then be logged against all breath test readings performed thereafter while ever the device remains on refer Figure 30 Whatever configuration is chosen on Static Mode the device will always acquire the location prior to the first test Then you have a choice of the following three options a Positive Tests which will record the location only on positive readings b All tests which will record zero and positive readings or C Threshold which will only record readings above a defined threshold ga aU FUBIUPIDMEE aed MU Locating GPS Position GPS Position Found Figure 30 Locating GPS Position and notifying GPS Position Found 5 4 Mobile GPS Mode Operations Mobile GPS Mode Operations is the default mode if the GPS function is enabled In this mode the device will log a GPS position fix with every Standard Active Breath Test when the BAC reading is displayed
18. aph 6 3 1 b With Connect Mode highlighted press the Test key C Permanent will be displayed ref Figure 42 1 Bi n 1 f 1 1 E i Q T 5 en b i Permanent Printer Pairing Edit BlueTooth PIN Connect Mode Auto Send Standard Auto Send Passive Auto Print Standard Auto Print Passive v Figure 42 Permanent Connect Mode 6 4 Auto Send NOTE To ensure the correct operation of the Auto Send function Auto Print Standard and Auto Print Passive must be set to None The Auto Send functions allow the automatic sending of results via a Bluetooth connection to a paired device laptop computer PC in a serial data format The data can be read received by a serial terminal application e g Putty Page 29 of 43 V1 2 Alcolizer Alcolizer LE5 User Manual technology There are two Auto Send modes and each of these has three options These are Auto Send Standard and Auto Send Passive Both have the following options Positive sends positive results after test is completed e All sends positive and zero results after test is completed None 6 4 1 Auto Send Standard Auto Send Standard applies only to Mouthpiece Active testing Depending on the Auto Send Standard option selected the following information will be transmitted following tests e Positive if alcohol is detected a complete report including time location lat long if GPS enabled test type result etc will be transmitted e
19. ata gt Printer setup and l Records information These and other displays are explained in the Operating Instructions Section 2 2 3 Mouthpiece Locator and Sample Inlet Spigot The disposable mouthpiece sample tube is located on the Mouthpiece Locator which surrounds the Sample Inlet Spigot 2 2 4 Up and Down Buttons The Up and Down buttons allow access to various sub menus Operation of both buttons also facilitates access to the Off function refer Section 3 2 2 5 USB Port The USB port facilitates connection of the device to a USB equipped computer using the cable included with the device Refer to Section 11 for instructions on using the Alcoconnect toolbox 2 2 6 Battery Charger Port Li ION powered devices only The Battery Charging Port installed only on the Li ION powered devices is located beneath a moisture proof cap under the wrist strap bracket and facilitates connection to the battery chargers included with the device 2 2 7 AA Battery Compartment Alkaline powered devices only The AA Alkaline battery compartment installed only on the AA Alkaline powered devices is located beneath a dust proof cap adjacent to the wrist strap bracket For access to the compartment refer to paragraph 3 5 J OPERATING INSTRUCTIONS CAUTION While the LE5 is a robust device it does contain sensitive instrumentation and should not be subject to rough handling or become submerged in water Do not store device
20. ation 2 07 2014 10 59 AM Application Libraries Documents 2 Music i Pictures E Videos s Computer amp Acer C amp DVD RW Drive D LES Alcoconnect setup Date modified 2 07 2014 10 59 AM Date created 2 07 2014 10 59 AM Application Size 450 KB Figure 57 CD Files list d On the Alcoconnect Setup window click Install refer Figure 58 Alcoconnect Setup Figure 58 Alcoconnect Setup window e Once the program is installed the Alcoconnect Setup window will display Setup Successful Click on Close refer Figure 59 Alcoconnect Setup Alcoconnect Setup Successful Figure 59 Setup Successful Following a successful installation an Alcoconnect icon will appear on the Desktop 11 2 Using Alcoconnect Once installed onto the computer access Alcoconnect as follows a Connect the device to the computer via the USB cable refer Figure 1 b Double click the Alcoconnect icon Page 40 of 43 V1 2 Alcolize f Alcolizer LE5 User Manual technology C Turn the LES device on refer paragraph 3 6 The Head Event Log window will be displayed refer Figure 60 A successful connection between the LE5 and the computer will be shown by a green segment on the Read Event Log window refer Figure 60 Alcolizer Pty Ltd Alcoconni File LogRecords About g Set Access Read Event Log Setup Figure 60 Read Event Log Window d Click the Read
21. ces in a responsible manner To perform another breath test repeat the steps in paragraph 3 6 1 3 6 4 Passive Testing Passive testing is a test that is performed in a non invasive manner and without using mouthpieces The LE5 can perform two types of Passive testing These are Passive Standard and Passive Only All Passive testing is performed by holding the device approximately 80mm to 100mm in front of the test subjects mouth and asking them to count or talk so that exhaled breath may be picked up by the device and analysed for the presence of any alcohol When using Passive Standard testing a Mouthpiece test is automatically enabled should the device detect alcohol on the subject s exhaled breath Passive Only testing does not prompt the user for further testing 3 6 5 Enabling Passive Standard If Passive standard mode has not been enabled proceed as follows a With the screen displaying press to test press the Up and Down buttons simultaneously The User Menu will be displayed b Press the down button to scroll down to Test Type refer Figure 15 16 09 2014 12 34 0 um Standard Test Type a Test Type Print Li Print Record Records About v Figure 15 Test Type displayed Page 16 of 43 V1 2 Alcolizer Alcolizer LE5 User Manual technology C Press the Test key until Passive Std is displayed refer Figure 16 16 09 2014 12 34 e num Test Type GPS Area Code Test Type Print Last
22. creen so another sample can be taken 2010 05 19 0950 0 E INVALID SAMPLE TRY AGAIN Figure 12 Invalid Sample try Again message 3 6 3 Analysing a Mouthpiece Breath Sample After a valid breath sample is taken the Analysing Sample message is displayed until the device calculates the BAC reading This will normally take a few seconds In cold climate conditions it may take longer to display the BAC reading refer Figure 13 2010 05 18 09 46 e Cun Figure 13 Analysing sample message When the BAC reading is calculated it will be displayed on the screen together with unit of measurement e g g 100ml g 210L and be retained until the Recovering period has ended The screen colour will vary depending on the percentage of alcohol present green for zero orange for zero to 0 049 g 100ml g 210L and red for readings greater than 0 05 g 100ml g 210L The Recovering period is indicated by Recovering shown on the display refer Figure 14 Page 15 of 43 V1 2 Alcolizer Alcolizer LE5 User Manual technology 2010 05 19 09 45 e Cum 2010 05 21 18 13 Ca Figure 14 Various BAC and screen colours displayed The Recovering period is the time the fuel cell sensor requires to recover from the previous breath test This period will vary according to BAC readings displayed longer for higher readings Remove the used mouthpiece by rotating it It will come away from the spigot easily Dispose of mouthpie
23. ction as the Read 3 Log Records Event Log icon Main Serial 4 The serial number of the LE5 Number D Se Sen The serial number of the sample module Number Record Number The number of each record Event Type The type of test performed or event E g breath test type passive standard test timeout or refusal etc Date and Time The data and time of the event The latitude taken for the GPS if installed and enabled of the 10 Latitude event The longitude taken for the GPS if installed and enabled of the Longitude event Used by authorised persons to access certain Alcoconnect Set Access functionality Select the icon after inputting correct access code 11 2 2 Set Log Settings Filtering data To filter the data access the Log Settings by clicking on File then Options The Log Setting window will appear refer Figure 62 The required criteria can be made by enabling dis enabling the record types 11 2 3 Saving Event Logs Event Logs can be saved for future analysis by clicking File then Save Event Log The data can then be saved to the required location on the PC or laptop as a csv or xml file To maintain the security of data files must be saved and protected by the user Page 42 of 43 V1 2 Alcolizer Alcolizer LE5 User Manual technology ie Bm mS S SS S C C a j S 3 Figure 62 Log Settings wi
24. displaying press to test Press the Up and Down buttons simultaneously for approximately five seconds The menu screen will be displayed during this process and then the password set up code 00000000 will be displayed refer Figure 32 19 06 2012 10 45 e TF 00000000 Figure 32 Password set up code 00000000 Press the Test key until the cursor is under the fifth O Press the Up button until that number is 5 refer Figure 33 19 06 2012 10 51 Gumi 00005000 Figure 33 Password set up code 00005000 Page 25 of 43 V1 2 SA lcolizer Alcolizer LE5 User Manual technology e Press the Test key until the Set up menu is displayed f Press the Down button until Bluetooth Comms is highlighted refer Figure 34 22 10 2014 12 20e Ci Bluetooth Comms e amp Time d Prompts st Modes Figure 34 Bluetooth Comms g Press the Test key The printer pairing screen will be displayed refer Figure 35 22 10 2014 12 28 e Cit Printer Pairing C F inter Pairing Edit Giue 1 gorn RIN Connect Mode Auto Send Standard Auto Send Passive Auto Print Standard Auto Print Passive YT Figure 35 Printer pairing screen h Place the LE5 device next to the Bluetooth printer and then switch the printer on l Press the Test Key The LE5 will search for the printer and display Searching refer Figure 36 22 10 2014 12 28 e Ci Searching Printer
25. e regardless of results nothing transmitted To set the LE5 to Auto Send Passive scroll down until Auto Print Passive is highlighted in a similar manner to Auto Send Passive Figure 44 Positive is the default option To select A or None press the Test key until the desired option is highlighted 6 6 Setting the Bluetooth printer PIN Once the printer driver is installed in may be necessary to set the correct PIN for the printer To set the PIN proceed as follows a Access the printer menu as described in paragraphs 6 1 a to 6 1 g NOTE It may not be necessary to follow all of the procedures above depending on the last screen that was displayed b Press the Down button and scroll to Edit Blue Tooth PIN C Press the Test key Enter pin length will be displayed refer Figure 45 22 10 2014 15 lt gt Gi 4 Enter pin length Printor Dsirina I Edit BlueTooth PIN Connect Mode Auto Send Standard Auto Send Passive Auto Print Standard Auto Print Passive Y Figure 45 Enter pin length displayed d Refer to Table 2 for the particular printer PIN length and number The Communications Range is provided as additional information Table 2 Printer pin length displayed Standard Printers bel Communication Range Length 4 Bixolon SPP R200 0000 Up to 10 metres Axiohm 631 631200 Up to 10 metres Custom S Print 12345 Up to 5 metres NOTE If the printer is not listed refer to the printer User Manual for P
26. e Up down buttons to navigate through records as required f Press the Up and Down buttons simultaneously to return to the User Menu NOTE For information about printing records refer to paragraph 6 7 8 2 Clearing Records As the device automatically stores records the memory will eventually reach capacity and unless the data is downloaded the storage of records will cease The device provides a series of warnings regarding memory capacity including memory reaching capacity memory full and days since the memory has been full refer Figure 52 Memory capacity warnings 20 09 2014 15 12 lt OmMEE20 09 2014 15 25 0 GMRR20 08 2014 15 06 0 il Memory reaching Record memory full Records Warning capacity Please Download records 20 Days Please download records for continued testing download and clear press Q to test Figure 52 Memory capacity warnings Page 36 of 43 V1 2 SA lcolizer Alcolizer LE5 User Manual technology 9 CALIBRATION 9 1 Calibration alerts The Alcolizer LE5 requires calibration every six months 190 days as per Australian Standards Certification requirement The device will display a warning message after switch on if 14 days or less remain before calibration is required refer Figure 53 Days to calibration displayed 14 days to 7 days to recalibration recalibration Figure 53 Days to calibration displayed To cancel the warning messages press the Test key The d
27. e the Up down buttons to advance the digit to the required number e When the correct number is displayed press the Test key The number will be set and the cursor will move the next digit f Repeat the steps at paragraph e until all the numbers required are displayed refer Figure 50 23 10 2014 10 07 lt Gili 111190 Area Code Area Code Test Type Print Last Print Record Records About Figure 50 Area Code Set The Area Code is now set m h Press the Down button until Back is displayed l Press the Test Key to return to the press to test screen 8 RECORDS 8 1 Accessing Records Records are retained in the instrument and can be downloaded via the Alcoconnect software support refer section 11 It is recommended that records are periodically downloaded and erased from the device refer paragraph 8 2 Access the records as follows a Switch the device on refer paragraph 3 6 Page 35 of 43 V1 2 Alcolizer Alcolizer LE5 User Manual technology b With the screen displaying press to test press the Up and Down buttons simultaneously The User Menu will be displayed refer Figure 15 Test Type displayed C Using the down button scroll down to Records refer Figure 51 Records displayed TEIR SEA Memory Used 2 GPS Area Code Test Type Print Last Print ADUUL v Figure 51 Records displayed d Press Test key to activate the records e Press th
28. eeceeceece eee eeeeeeeeseeseeseeeeeeeeaeeseeseeseeseeeeeeaes 18 Figure 20 Warning Alcohol Present MESSAGE ccccceecsecceeceeceeteeeeeeaeeaeeseeseeseeeeeeeeeaes 19 Figure 21 Warning Alcohol Present Press for Active Test display 19 Figure 22 Screen Back selection r arrnarrnnrnanrnnrnanrnnrnannnnrnannnnrnannnarnnnnnannnnnnannnnennnnnnennnenee 20 Fig r 293 TAS Cave 20 Figure 24 Test Options Menu and Test Cancel rrarnnnrnannnnrnannnarnnnnnarnnnrnnnnnnnnannnnnnnennnnnenn 21 Figure 25 Test Refuse displayed cccccccceccecceeeceeeceeceeeseeceeecuecaeeceeseeeseeseesaeseeeeeeeeeeaes 21 Figure 26 Test Refused displayed cccccccccceccecceeeceeceeeseeceeeceeceeeseeseeeceesaeeceeseueseesaeesaes 22 Figure 2 GIS zi Ne 22 Iure 25e OP ACU ON scoop tomba duis E eee eee eee et eee eee eee 23 Figure 29 GPS position on Menu Screen ccc cece cece ecceeeseeceeeceeceeeseeeeeeseecseeseeeseeeeeeseesaes 23 Figure 30 Locating GPS Position and notifying GPS Position Found 24 Figure 31 GPS Position displayed in Records ccccccecceceeeeceeeeeeeeeeeeeceeeeeeeeeeaeeseeeaeesees 24 Figure 32 Password set up code 00000000 rarrarnnrrnrrnrrnernarnnrnnrnnnnnernernernarnnrnnannannennennenner 25 Figure 33 Password set up code 00005000 rrrrnnrrnnrnnrnnnrvnnrnnnnnnnnarnnrrnnnnnnennennnennnn
29. erative Charge the battery as follows a Connect the charger DC socket to the LE5 battery charging port refer Figure 1 b Connect the AC or DC vehicle plug to a suitable power supply and switch on power The device will automatically start and Charging will be displayed When the battery is fully charged the battery condition indicator on the LCD Colour Graphics Display will display five bars refer Figure 4 10 09 2014 11 11 04 OG Figure 4 Battery Condition Indicator Page 10 of 43 V1 2 Alcolizer Alcolizer LE5 User Manual technology Recharge the battery when the battery condition indicator shows one bar to ensure testing will not be interrupted by a flat battery NOTE The device cannot be used for testing during charging but can be used for accessing Records refer Section 8 3 5 Changing the batteries AA Alkaline powered device Prior to initial use the LE5 batteries should be new Alcolizer recommend the use of Eveready AA Alkaline EN91 batteries for the LE5 Change the batteries in accordance with the following procedures refer Figure 5 a Invert the device so the compartment hatch is upper most refer Figure 5a b Access the battery compartment by pressing the compartment release button on the underside of the device refer Figure 5a The compartment hatch will pop out NOTE If the device has a silicon cover installed the release button is operatable by pressing the raised porti
30. evice will resume normal operation until Zero days to re calibration is reached When the re calibration warning message period has expired the Recalibration Due Now screen is displayed and the device is locked preventing any further breath tests until the device is re calibrated refer Figure 54 12 09 2014 14 39e lt gt Gi Recalibration Due Now Call 1300 485 177 for Service Quote 26400380 Figure 54 Recalibration Due Now message CAUTION It is recommended that calibration of the device is performed before the warning message period expires This will ensure uninterrupted testing can continue 9 2 Replacing sample module Rather than returning the device to Alcolizer for calibration the sample module can be removed and sent in This saves money and if the owner details are known and maintained with Alcolizer arrangements can be made to forward a replacement sample module prior to the calibration being overdue Remove and replace the sample module as follows refer Figure 55 Page 37 of 43 V1 2 Alcolize f Alcolizer LE5 User Manual technology Undo the single screw on the back of the main module olide off the out of cal sample module Slide on the new sample module o ocn Do up the single screw on the back of the main module CAUTION Do not over tighten the sample module securing screw as this will damage the threaded portion Tighten only enough to prevent the sample module from sliding away
31. g or metal case optional and e Bluetooth printer optional 2 2 Device Overview The LE5 is a handheld device consisting of a hard plastic outer case optional silicon cover wrist strap and the following user displays buttons and adaptor sockets refer Figure 1 a Test Key LCD Colour Graphics Display Mouthpiece Locator and Sample Inlet Spigot USB Port and b C d Up and Down buttons e f Battery Charging Port AA Alkaline Battery Compartment refer Figure 2 Page 6 of 43 V1 2 Alcolizer Alcolizer LE5 User Manual technology Mouthpiece spigot locator c LCD Colour Graphics Display b USB Port e Test Key a Up Button d Down Button d Silicon Cover Battery Charging Port AA Battery Compartment f eed Figure 1 User Display Buttons and Adapter Sockets Figure 2 Charging Port left and AA Battery Compartment right 2 2 1 Test Key The Test Key activates selected functions 2 2 2 LCD Colour Graphics Display Displays the various functions of the device including Page 7 of 43 V1 2 SA lcolizer Alcolizer LE5 User Manual technology Welcome screen which includes days remaining till next calibration if activated Various Test modes Mouthpiece Passive Standard and Passive Only Extensive menus and options Ready notification Blow notification including progress bar 9 29 5 BAC level in various formats GPS acquisition d
32. in direct sunlight or places where extreme temperature conditions can occur Page 8 of 43 V1 2 Alcolize f Alcolizer LE5 User Manual technology NOTE The LES has optional functions which may or may not be active on your device The screen images shown in this User Manual may differ to your device depending on the options fitted or functions enabled 3 1 General Information The following information should be observed when conducting breath test analysis using this device a To obtain an accurate reading alcohol should not be consumed or mouthwash containing alcohol used for at least 15 minutes prior to using this device b Blood Alcohol Concentration BAC readings can continue to rise or fluctuate for up to two hours after alcohol was last consumed Should the BAC readings be near or over the local threshold drinking should cease then a re test conducted after 15 minutes C Driving or operating machinery should not occur until a new test shows a decline in BAC reading and the BAC reading is below the local legislation legal limit d It can take up to one hour for the average person s system to absorb a 0 01 BAC before the level returns to zero In such circumstances further testing later in the day or the following morning is strongly recommended 3 2 Testing Types The LE5 can perform both Mouthpiece and Passive Passive Standard and Passive Only testing Mouthpiece testing provides a BAC reading in g 100ml or
33. ing steps With the Blow screen displayed Press the Up and Down buttons simultaneously The Test Options Menu and Test Cancel is displayed refer Figure 24 15 09 2014 14 38 e um a Figure 24 Test Options Menu and Test Cancel b Press the Test key The screen will return to the press to test display 4 2 Test Refusal If a test is refused the user can activate the Test Refuse option as follows With the Blow screen displayed press the Up and Down buttons simultaneously The Test Options Menu and Test Cancel is displayed refer Figure 24 b Press the Down button to highlight Test Refuse refer Figure 25 16 09 2014 14 47 4 um a t Cancel ist Refuse Back Figure 25 Test Refuse displayed Press the Test key The device will beep rapidly for one second and Test Refused will be displayed flashing momentarily refer Figure 26 The screen will then return to the press to test display The test refusal will be recorded in Records Page 21 of 43 V1 2 SA lcolizer Alcolizer LE5 User Manual technology 16 09 2014 14 47 e uui Test Refused Test Cancel Test Refuse 4 Back Figure 26 Test Refused displayed 9 GPS The Global Positioning System GPS function if installed enables the exact location of the device to be known and under certain circumstances the location of testing to be recorded Two GPS mode functions are available Mobile and Static NOTE Depending on the
34. nd Please wait and a progress bar will be displayed NOTE If the self check is unsuccessful an error code will be displayed and the device will not accept a breath sample b BLOW will be displayed when the device is ready refer Figure 9 Page 13 of 43 V1 2 Alcolizer Alcolizer LE5 User Manual technology 2010 05 19 09 MIL e Flow L min 10 Time 2 Lei Figure 9 Blow is displayed when device is ready C After taking a deep breath the test subject places their mouth over mouthpiece inlet ribbed end and blows a gentle to medium breath sample into the mouth piece refer Figure 10 Figure 10 Providing a sample d The exhaled breath volume is indicated via a bar graph scrolling left to right at the bottom the screen and a graph showing air flow over time in seconds refer Figure 11 A beeping sound is also heard during the breath sample delivery phase indicating a satisfactory breath sample is being delivered Figure 11 Sample progress bar Page 14 of 43 V1 2 SA lcolizer Alcolizer LE5 User Manual technology e The test subject continues blowing until the device takes a sample of the exhaled breath volume indicated by a click and long beep sound The frequency of the sound beeps increases with the intensity of the blow pressure Blowing too hard or too soft will result in Invalid Sample Try Again being displayed refer Figure 12 The device will return to the Blow s
35. ndow 11 2 4 Erasing event logs or Clear log on device Insert access code 00005000 at set address field to enable additional features Page 43 of 43 V1 2
36. ng the Bluetooth printer PIN rrurranrnnnrnanrnnrnanrnarnanrnannnnrnarnnnnnannnnenuannnnnsnnenn 32 bo FINE UNS 33 AREA C OD 2 34 RECORDS 2 35 OL ACCESSING REN 35 92 HAMREN aer uetus eee eee ne ee ee ee eee ee eee eee 36 2 CALIBRATION co 37 9 1 Calibration Alerts ccc cece ccccccccccccccccccccccecceccececceaceaeuuecceneuueaeeceeneaueceetaneneenees 37 9 2 Replacing sample module cece ccc ecc eee eeceec eee eeeeceeceeceeeeceeceeceeseeseeseeeseeseeseees 3 10 GG 0 ON 38 iE E0200 1045 Rm 39 Page 2 of 43 V12 Alcolizer Alcolizer LE5 User Manual technology 11 1 Installing Alcoconnect Software rrarrrarnnrrrarnnrrrannnerrnnnnernnnnnarnnnrnarnnnenaennsennannenn 39 11 2 UN ies cedido NT T TT T TM 40 7 Figure 1 User Display Buttons and Adapter Sockets ccccccceccsecceeeeeeeeeeaeeceeeeeeeeeeaeeees T Figure 2 Charging Port left and AA Battery Compartment right T Figure 3 Mouthpiece Type sS cccccccsccceccecceeceeceecaecaeceecceeceeceesuesuesaeeeeeceeseesaesaesaesaesaeeees 10 Figure 4 Battery Condition Indicator rarrnnrnanrnnrnannnnrnanrnnrnannnnrnannnarnnnnnannnnrnannnnennnnnnennnenee 10 Figure 5 Installing Replacing AA Alkaline Batteries rrrrrrarrrerrarerarrnrrrarrnrrrarnnnrrnnnnrnnnnner
37. nnennnnnen 25 Figure 34 Bluetooth COMMS avsmak eie Siu adiu desi e 26 Figure 35 Printer pairing screen cccccccceeccecceeceeceeceecuecaecceeceeceesuesuesuesaesaeeceeceesensansaesaes 26 Figure 36 Searching displayed sesessssssessssssessssseeeeee nennen nnne nnns 26 FIGURE 37 Printer identified cote diee irt oor ticas rideo dei 2f Figure 38 Printer Driver displayed ccccccceeceeceeceeceeseecceeceeceeceesuesuesesaeeceeseeseesensansass 2 Figure 39 Printer brand and type displayed rrarrarrnrrnnrnrrarrnrnnrnnnnnnrnernerrernnennnnnannnnnennenner 28 Figure 40 Bluetooth icon on SCIEN ccccecceecceeceeceeceecececceeceeceeceeseecuesaesaeeceeseeseesansansass 28 Figure 41 Setting Connect MOde cccceccccccecceeeceeeeeeceeeseeceeeseeceeeseeeeeeseeeseeseesseeseeeseeeaes 29 Figure 42 Permanent Connect Mode cccccccsecceceeeeceeeeeeceeeeeeceeeseeeeeeseesseeseeeseeeeeegeesees 29 Figure 43 Auto Send Standard with the three options ccccccceccseeceeeceeeeeeceeeeeeeeeeeeeeees 30 Figure 44 Auto Send Passive with the three Options ccc cccceeeeeeeeeeeeeeeeeeeeeeeseeeeeseees 31 Page 3 of 43 V1 2 Alcolizer technology Figure 45 Enter pin length displayed Figure 46 PINS entered ccccecceeceeceeceeceeeeeeceeceeseeseesensaees Figure 47
38. nnrnarnnnnnnnnnnnnnnennenner 10 3 5 Changing the batteries AA Alkaline powered device 11 30 PT N S 12 BRNO NN 20 NN 20 4 TEST OPTIONS MENU needed 21 AT TET MEN 21 4 2 Test Refusal ccc cc ccc cc ccccccccccccccccccccceccccecceacenecueaeenecueceenecneceenecneaueceeneaeecesntaneass 21 MEE CULO RR 22 9 1 Acquiring GPS satellites ternum honor ns seme v rona tinm inue divus iae bci ds 22 5 2 GPS Mode COnsiguration cccccccsccsecceeccecseecceeceeeceesaneceesaneceesaeeseesaeeseesaeesans 23 9 9 Static GPS Mode OPElallONS issus ensisai xxsenatiduzbisa uxor alind PI Sa U Ki Ova E EU PC VE ME eaaa 24 5 4 Mobile GPS Mode Operations ssesesssssssseene mener 24 6 SENDING AND PRINTING DATA anvavnnvnnnnvnnvnnvnnnannnvnnvavnnrnnvannnvnnvnnnavnnvnnvavnnvnnvanvnvnnnn 25 6 1 Bluetooth Connection cssessssess RR IR IR Rm RmRttRettIttrtttttetttttttittrrrtriiis 25 6 2 Printer driver ccc cccccccccccccccccceccccecceccecuecuecneeecaueueeneenueauenuenueaueauecneaueanecneeneeneenees 27 6 3 Connect Mode ccc cccccccccccccccceccaccceccecccccccececueccenecuecceceeneaueceeneaueaeeneaneaeeneaneaees 28 6 4 Auto Send rarrnrnnrannnnnnrnnnnrnnrnnsnrsnrnnsnsnnsnnsnsnnsnnsnssnrnnsnnsnennsansnennsnnsnnnnsnnsnnnnsnnnnennsne 29 AWO PIM Ne 31 6 6 Setti
39. ollowing procedures must be strictly adhered to Attach the mouthpiece to the device as follows a Grasp the mouthpiece at the non ribbed end and tear the plastic wrapping from the ribbed end downwards to expose the sample inlet hole b Locate the mouthpiece sample inlet port over the mouthpiece locator in line with the recesses that surround the spigot refer Figure 7 C Press the mouthpiece sample inlet port onto the locator until it is attached securely refer Figure 8 The orientation of the mouthpiece will not affect the sampling d Remove the remaining portion of the plastic wrap just prior to testing to ensure hygienic use Page 12 of 43 V1 2 Alcolize f Alcolizer LE5 User Manual technology Figure 7 Locating the Mouthpiece Figure 8 Mouthpiece correctly positioned 3 6 2 Taking a Mouthpiece Active Breath Sample NOTE Before taking a breath sample ensure the subject has not consumed alcohol for at least 15 minutes If any step in a breath test sequence is not completed or the device is left idle for a prolonged period of time then the device will terminate the breath test and display Test timed out The device will return to the press to test display The standard breath test time out period is 60 seconds If a test time out does occur during a breath test a new breath test must be performed Perform a Mouthpiece Test as follows a Press the Test key The device will perform a self test a
40. on over the button on the back of the device Removal of the cover is not required to change the batteries Open the hatch by gently moving it to expose the compartment refer Figure 5b Remove the flat batteries and insert two new batteries ensuring the polarity is correct Polarity markings 0 and are marked on the hatch contactor refer Figure 5b e Close the hatch by gently positioning it in place and pressing it closed refer Figure 5c A click indicates the hatch is locked Figure 5 Installing Replacing AA Alkaline Batteries Page 11 of 43 V1 2 SA lcolizer Alcolizer LE5 User Manual technology 3 6 Turning On Device Turn the device on as follows a Press either the Test key or Up down buttons A company logo screen will appear for a period of five seconds prior to the test screen displaying The logo screen can be terminated sooner by pressing either the Test key or Up down buttons a second time NOTE On specially configured devices additional information may be displayed on start up e g Device serial number Sample module serial number and days till calibration To permanently display this information hold the Test key down for an extended period upon start up b The Display will show press to test refer Figure 6 2000 01 08 10 36 ez um Dress to test Figure 6 Press to test message 3 6 1 Mouthpiece Testing CAUTION To maintain a healthy sampling environment the f
41. other formats as required and Passive testing will display the presence of alcohol in breath Following a Passive test that indicates the presence of alcohol a Mouthpiece test should then be performed if an accurate BAC is required NOTE Mouthpiece testing is also referred to as Standard or Active testing 3 3 Mouthpieces There are two types of Mouthpieces available for use on the LES refer Figure 3 These are the e Spit Trap Non Return Valve Mouthpiece 2 variants and e Standard Spigot Locator Mouthpiece Page 9 of 43 V1 2 Alcolizer Alcolizer LE5 User Manual technology Ribbed end Non return spit trap mouthpieces Sample inlet ports Standard mouthpiece Non ribbed end Figure 3 Mouthpiece Types The advantage of using the spit trap type mouthpieces is that most of the saliva in the exhaled breath is collected in the mouthpiece and does not enter the device 3 4 Charging the Battery Li ION powered device Prior to initial use the LES battery should be fully charged The battery charge cycle may take up to two hours CAUTION The battery in the LE5 device is a Li ION battery As such it should not be tampered with in anyway Should any problems occur that are related to the battery contact your local Alcolizer representative for advice Only use the battery charger supplied with the Alcolizer supplied equipment Use of non Alcolizer battery chargers could damage the device and render it inop
42. re 47 Print Last displayed C Press the Test key The printer will print the last test To print a record perform the following procedures a With the screen displaying press to test press the Up and Down buttons simultaneously The User Menu will be displayed refer Figure 15 b Press the Down button and scroll to Print Record refer Figure 48 23 10 2014 09 3 lt gt Gil Print Record GPS Area Code Test Type Print I act orint Record Records About Figure 48 Print Record displayed C Press the Test key Records will be displayed d Press the Up Down buttons as needed to locate the record required e When the required record is located press the Test key The record will be printed NOTE For information about Records refer to Section 8 T AREA CODE Area codes are used to identify the location of a breath test To set an area code perform the following procedures a With the screen displaying press to test press the Up and Down buttons simultaneously The User Menu will be displayed refer Figure 15 b Press the Down button and scroll to Area Code refer Figure 49 Page 34 of 43 V1 2 Alcolizer Alcolizer LE5 User Manual technology 23 10 2014 09 54 0 Gili 000000 Area Code GPS a Code est I ype Print Last Print Record Records About Ld Figure 49 Area Code displayed C Press the Test key The cursor will move below the first digit Us
43. ro results after test is completed e None 6 5 1 Auto Print Standard Auto Print Standard applies only to Mouthpiece Active testing Depending on the Auto Print Standard option selected the following information will be printed following tests e Positive if alcohol is detected a complete report including time location lat long if GPS enabled test type result etc will be printed e All regardless of results a complete report including time location lat long if GPS enabled test type result etc will be printed To set the LE5 to Auto Print Standard scroll down until Auto Print Standard is highlighted in a similar manner to Auto Send Standard Figure 43 Positive is the default option To select A or None press the Test key until the desired option is highlighted 6 5 2 Auto Print Passive Auto Print Passive applies only to Passive testing Depending on the Auto Print Passive option selected the information may be printed following the various tests except None The result will be either false if no alcohol is detected or true if alcohol is detected per the following explanations e Positive if alcohol is detected A short report including time device information test type etc will be printed e All if alcohol is either detected or not a short report including time device information test type etc will be printed Page 31 of 43 V1 2 Alcolize f Alcolizer LE5 User Manual technology e Non
44. specific configuration of the device the GPS functions are either enabled or disabled These functions are generally enabled as a Customer requirement by Alcolizer Technology Should the device in use require the enabling of certain GPS functionality contact Alcolizer Technology for further advice 5 1 Acquiring GPS satellites To acquire GPS satellites perform the following steps a With the screen displaying press to test Press the Up and Down buttons simultaneously The User Menu will be displayed refer Figure 15 b Press the Down button to highlight GPS refer Figure 27 16 09 2014 15 18 2 um Area Code Test Type Frint Last Print Record Records About Figure 27 GPS displayed C Press the Test key The GPS acquisition screen will be displayed Page 22 of 43 V1 2 Alcolizer Alcolizer LE5 User Manual technology As each satellite is acquired the respective yellow bar and satellite number will be displayed and its location will be displayed on the map Once sufficient satellites are acquired for an accurate position the Latitude and Longitude will be displayed refer Figure 28 16 09 2014 15 47 lt gt Gil Latitude 527 53133 E153 26595 Figure 28 GPS Acquisition Once the GPS location is acquired it will be visible on the menu screen refer Figure 29 20 10 2014 Latitude S27 53124 Longitude E153 26552 md 7 7 7 Of FA Nw gt v2 auss GPS Are
45. transmitted e None regardless of results nothing transmitted To set the LE5 to Auto Send Passive scroll down until Auto Send Passive is highlighted Positive is the default option To select A or None press the Test key until the desired option is highlighted refer Figure 44 Page 30 of 43 V1 2 Alcolizer technology 16 04 2046 10 11 e I Printer Pairing Edit BlueTooth PIN Connect Mo de almer Fagus MSIE Ato m EE Auto Print Passive T 18 01 2015 10 12e uto Send Passive Printer Pairing Edit BlueTooth PIN Connect Mode Auto Send Standard Auto Send Passive Auto Print Standard Auto Print Passive Alcolizer LE5 User Manual 18 01 2015 10 12 64 Gill end Passive Printer Pairing Edit BlueTooth PIN Connect Mode Auto Send Standard Aulo Send Passive Auto Print Standard Auto Print Passive T Figure 44 Auto Send Passive with the three options 6 5 Auto Print NOTE To ensure the correct operation of the Auto Print function Auto Send Standard and Auto Send Passive must be set to None The Auto Print functions allow the automatic printing of results via a Bluetooth connection to a paired printer There are two Auto Print modes and each of these has three options These are Auto Print Standard and Auto Print Passive Both have the following options Positive prints positive results after test is completed All prints positive and ze