Home
        JY997D22801-K - Mitsubishi Electric
         Contents
1.        Specifications  Item  GT1155HS QSBD    GT Designer2 Version2 15R or later GT Designer3 Version1 01B or later    GT1150HS QLBD  Compatible software package     1    Bright dots  always lit  and dark dots  unlit  may appear on a liquid crystal display panel  It is impossible to completely avoid this symptom  as the liquid crystal display   comprises of a great number of display elements  Flickers may be observed depending on the display color   Please note that these dots appear due to its characteristic and are not caused by product defect    e Flickers and partial discoloration may be generated on the liquid crystal display panel due to the display contents or the contrast adjustment  However  please note  that these phenomena appear due to its characteristic and are not caused by product defect    e There is a difference in the display brightness and the color tones between liquid crystal display panels  When using multiple liquid crystal display panels  please note  that there is an individual difference between them    e A crosstalk  shadow as an extension of the display  may appear on the liquid crystal display panel  Please note that it appears due to its characteristic    e When the display section is seen from the outside of the display angle  the display color seems like it has changed  Please note that it is due to its characteristic   Please note that the response time  brightness and color of the liquid crystal display panel may vary depending on the usage e
2.   GT11 Handy GOT User   s Manual    protection  back cover  screw    back cover  screw       e How to confirm production year and month  The production year and month of the battery built in the purchased GOT can be  confirmed by the production No   S N  marked on the GOT main unit     Example nameplate   manufacture s serial number 1010001                    GRAPHIC OPERATION TERMINAL  MODEL GT1155HS QSBD  IN 20 4 26 4VDC POWER 9 84W MAX    SIN  1010001 AJ     AJ     MITSUBISHI ELECTRIC CORPORATION Hardware version    MADE IN JAPAN     Actual product nameplate differs  from the example shown above    lt Dec   2009 or before gt   6 digit   9   x   o   o  fo  L   Control number  Month  example  Oct       1 to 9  Jan  to Sep    X  Oct   Y  Nov   Z  Dec     Year  example  2009   Last digit of year                 lt Jan   2010 or later gt   7 digit   1  fo   4   lollo   0  1   Control number  Month  example  Jan     1 to 9  Jan  to Sep    X  Oct   Y  Nov   Z  Dec     Year  example  2010   Last two digit of year          The production date of the optional replacement battery can be confirmed by the lot  No  marked on the nameplate  label  affixed on the battery     Nameplate         Connector    Model name    T11 50BAT  LOT       LOT 101        lt Jan   2010 or later gt        8i X     L Month     example  Jan     1  Jan   to 9  Sep      X  Oct    Y  Nov    Z  Dec    Year  example  2010   Last two digit of year     example  Oct     1  Jan   to 9  Sep      X  Oct    Y  Nov    Z  
3.   Make sure to attach the back cover to the Handy GOT before turning on the  power and starting operation after the installation or wiring work    Otherwise  electrical shock may be caused    Be sure to shut off all phases of the external power supply used by the system  before wiring  Failure to do so may result in an electric shock  product damage or  malfunctions    Please make sure to ground FG terminal of the GOT power supply section by  applying 100 or less which is used exclusively for the GOT  Not doing so may  cause an electric shock or malfunction    Correctly wire the GOT power supply section after confirming the rated voltage  and terminal arrangement of the product  Not doing so can cause a fire or failure   Exercise care to avoid foreign matter such as chips and wire offcuts entering the  GOT  Not doing so can cause a fire  failure or malfunction        WIRING PRECAUTIONS   c AUTION    e The cables connected to the unit must be run in ducts or clamped   Not doing so can cause the unit or cable to be damaged due to the dangling   motion or accidental pulling of the cables or can cause a malfunction due to a  cable connection fault   When unplugging the cable connected to the unit  do not hold and pull the cable  portion   Doing so can cause the unit or cable to be damaged or can cause a malfunction  due to a cable connection fault     Plug the communication cable into the connector of the connected unit and  tighten the mounting and terminal screws in the specifi
4.  CAUTION    e When transporting lithium batteries  make sure to treat them based on the  transport regulations   Refer to User s Manual for details of the regurated  models      Before transporting the GOT  turn the GOT power on and check that the battery  voltage status is normal on the Time setting  amp  display screen  utilities screen   In  addition  confirm that the adequate battery life remains on the rating plate   Transporting the GOT with the low battery voltage or the battery the reached  battery life may unstabilize the backup data unstable during transportation   Make sure to transport the GOT main unit and or relevant unit s  in the manner  they will not be exposed to the impact exceeding the impact resistance  described in the general specifications of this manual  as they are precision  devices  Failure to do so may cause the unit to fail    Check if the unit operates correctly after transportation        SH 080529ENG   1D7M24     SH 080530ENG   1D7M25     SH 080866ENG   1D7MB9     SH 080867ENG       The manual in PDF format is included in the GT Works2 GT Designer2 GT Works3 GT Designer3 products     For details of a PLC to be connected  refer to the PLC user s manual respectively     Bundled Items    Product Model  Name Name    GT1155HS    320 x 240 dots   STN color LCD  256 colors   built in   QSBD battery and backlight    GT1150HS    320 x 240 dots   STN monochrome LCD  black white  16   QLBD scales   built in battery and backlight    Specifications        
5.  GOT     1D7MC1   Describes the Handy GOT hardware relevant content such as part names  external JY997D20101  dimensions  mounting  power supply wiring  specifications  and introduction to option JY997D20102   09R817   Bundled item Quantity    Operation switch name character sheets   1  OHP sheet   2  Reference dimension sheet  switch name change sheet  mount     1  One sheet  2  One sheet    Selector switch keys 2  GT11 Handy GOT General Description  This manual  1       1  Features  1  Improved monitoring performance and connectivity to FA devices    Two types of display modes are provided  256 color display and monochrome display  In the monochrome display  16 scales are used to improve the display     High speed monitoring through high speed communication at maximum of 115 2kbps     Multiple languages are displayed using the Unicode2 1 compatible fonts and beautiful characters are drawn using the TrueType and high quality fonts     High speed display and high speed touch switch response   2  More efficient GOT operations including screen design  startup  adjustment  management and maintenance works    The display screen of the display unit is created using a drawing software for PC  GT Designer2 Ver2 18U or later GT Designer3 Ver1 01B or later      The 3MB user memory is included as standard     CF card interface is included as standard     The USB connector interface is included as standard   3  Enhanced support of FA device setup tools      Transferring or monitoring th
6.  a CF card into from the GOT  turn the CF card access  switch off in advance  Failure to do so may corrupt data within the CF card    When inserting a CF card into the GOT  push it into the insertion slot until the CF  card eject button will pop out  Failure to do so may cause a malfunction due to  poor contact    When removing a CF card from the GOT  make sure to support the CF card by  hand  as it may pop out  Failure to do so may cause the CF card to drop from the  GOT and break     Make sure to attach the back cover to the Handy GOT before turning on the  power and starting operation after the installation or wiring work    Otherwise  electrical shock may be caused    Be sure to shut off all phases of the external power supply used by the system  before wiring  Failure to do so may result in an electric shock  product damage or  malfunctions    Please make sure to ground FG terminal of the GOT power supply section by  applying 100 or less which is used exclusively for the GOT  Not doing so may  cause an electric shock or malfunction    Correctly wire the GOT power supply section after confirming the rated voltage  and terminal arrangement of the product  Not doing so can cause a fire or failure   Exercise care to avoid foreign matter such as chips and wire offcuts entering the  GOT  Not doing so can cause a fire  failure or malfunction        WIRING PRECAUTIONS   c AUTION    e The cables connected to the unit must be run in ducts or clamped   Not doing so can cause the un
7.  cable connector for PLC communication   12  Cable connector for   Connector for either  11  or  13  and for selection of  PLC communication   the PLC communication type   Connected to RS 422   before shipping      Opened and closed when the PLC communication    type is changed  RS 422  lt  RS 232  before shipping     RS 422   the option function board is mounted  or the  battery is replaced     Used to hold the Handy GOT in hand by putting a  hand under the strap  Length adjustable     Environmental  protection back  cover        13    RS 422 interface Connector for PLC communication using RS 422     14  Connector for option   Connector for mounting the GT11 50FNB type option  function board function board    For the connection to the controller  microcomputer board or PC  refer to the  following      5    Hand strap    Model  consumption current  serial No   Hardware      6    Rating plate Firmware version is indicated      7    Grip switch Switch for external direct wiring  independent contact         GT11 Handy GOT User   s Manual    3  Specifications  3 1 General Specifications  Item Specifications    Operating ambient Display section 0 to 40  C  temperature Other than Display section   0 to 40  C    Storage ambient temperature  20 to 60  C  Operating ambient humidity 10 to 90  RH  non condensing  The wet bulb temperature is 39  C or less      Storage ambient humidity 10 to 90  RH  non condensing  The wet bulb temperature is 39  C or less        Frequency     Acceleratio
8.  due to false output or malfunction     If a communication fault  including cable disconnection  occurs during  monitoring on the GOT  communication between the GOT and PLC CPU is  suspended and the GOT becomes inoperative    A system where the GOT is used should be configured to perform any  significant operation to the system by using the switches of a device other  than the GOT on the assumption that a GOT communication fault will occur   Not doing so can cause an accident due to false output or malfunction     Do not use the GOT as the warning device that may cause a serious  accident    An independent and redundant hardware or mechanical interlock is required  to configure the device that displays and outputs serious warning    Failure to observe this instruction may result in an accident due to incorrect  output or malfunction     Incorrect operation of the touch switch s  may lead to a serious accident if the  GOT backlight is gone out    When the GOT backlight goes out  the POWER LED flickers  green orange   and the display section turns black and causes the monitor screen to appear  blank  while the input of the touch switch s  remains active    This may confuse an operator in thinking that the GOT is in  screensaver   mode  who then tries to release the GOT from this mode by touching the  display section  which may cause a touch switch to operate    Note that the following occurs on the GOT when the backlight goes out       The POWER LED flickers  green orange  and 
9.  frequency     Dielectric withstand voltage 500V AC for 1 minute  across power supply terminals and earth     Insulation resistance 10MQ or larger by insulation resistance tester  across power supply terminals and earth        The GOT continues to operate even upon 5ms or shorter instantaneous power failure   The GOT stops operating if there is extended power failure or voltage drop  while it automatically resumes operation as soon as the power is restored     3 4 External Dimensions    18  0 71   75  2 96       gt   gt      72  2 84                           Unit  mm  inch     e How to confirm production year and month    The production year and month of the battery built in the purchased GOT can be  confirmed by the production No   S N  marked on the GOT main unit     Example nameplate   manufacture s serial number 1010001     5  Cautions on Using Emergency Stop Switch    1  When using the emergency stop switch in the handy GOT  judge the validity to  use the emergency stop switch in accordance with the risk assessment in your  system     2  When using the parallel circuit  which disables the emergency stop status while    the handy GOT is removed   the system may not conform to the safety  standards  Check the safety standards required in the system  and then judge  the validity to use the emergency stop switch     GRAPHIC OPERATION TERMINAL  MODEL GT1155HS QSBD    IN 20 4 26 4VDC POWER 9 84W MAX  SIN  4010001 KAN    AS     MITSUBISHI ELECTRIC CORPORATION    Hardware versi
10.  or slight personal injury  or physical damage   Depending on circumstances  procedures indicated by  CAUTION  may also be    linked to serious results   In any case  it is important to follow the directions for usage     DESIGN PRECAUTIONS   WARNING    e Some failures of the GOT or cable may keep the outputs on or off   An external monitoring circuit should be provided to check for output signals  which may lead to a serious accident   Not doing so can cause an accident due to false output or malfunction     If a communication fault  including cable disconnection  occurs during  monitoring on the GOT  communication between the GOT and PLC CPU is  suspended and the GOT becomes inoperative    A system where the GOT is used should be configured to perform any  significant operation to the system by using the switches of a device other  than the GOT on the assumption that a GOT communication fault will occur   Not doing so can cause an accident due to false output or malfunction     Do not use the GOT as the warning device that may cause a serious  accident    An independent and redundant hardware or mechanical interlock is required  to configure the device that displays and outputs serious warning    Failure to observe this instruction may result in an accident due to incorrect  output or malfunction     Incorrect operation of the touch switch s  may lead to a serious accident if the  GOT backlight is gone out    When the GOT backlight goes out  the POWER LED flickers  green or
11.  resistance load   Maximum rating 0 3A 24VDC  induction load   Life  100 000 times      PLC communication  Select either RS 422 or RS 232 when used       PC communication  Project data upload download  OS installation  transparent function     Switch Emergency stop switch  times  1 switch  single wiring   IDEC AS6Q 2KT1PB   Keylock switch   2 position switch  cannot be removed  Two keys are provided    1 LED  Lit in green  Power is correctly supplied   POWER LED Lit in orange  Screen saving and backlight not lit   LED Blinks in orange green  Blown back light bulb   Not lit  Power is not supplied   LED for operation switch display   6 LEDs  green  lighting control from the display section   LED for grip switch display 1 LED  green  lighting control from display unit part   Battery GT11 50BAT lithium battery  Magnesium maganese dioxide lithium primary battery  Backup target Clock data  alarm history and recipe data  Approx  5 years  Operating ambient temperature of 25  C   Guaranteed  1 year  RS422 RS232 1ch  Transmission speed   115 200 57 600 38 400 19 200 9 600 4 800bps  Ser ee eee Connector shape   Round 32 pins  male   Application  RS232 1ch  RS 232 Transmission speed   115 200 57 600 38 400 19 200 9 600 4 800bps  Connector shape   MINI DIN 6 pin  Female   Built in Application  intents USB  Full Speed 12Mbps  1ch  USB Connector shape  Mini B  Application    CF card  Application    Option function board 4    Environmental protective structure 5  External dimensions    Weigh
12.  settings of the object functions used in GT Designer2    Describes methods of the GT Designer3 installation operation  basic operation for drawing  and transmitting data to GOT1000 series    Describes specifications and settings of the object functions used in GT Designer3       Manual Number   Model Code     SH 080529ENG   1D7M24     SH 080530ENG   1D7M25     SH 080866ENG   1D7MB9     SH 080867ENG     sold separately   1 ome   GT11 Handy GOT User   s Manual Describes the Handy GOT hardware relevant content such as part names  external JY997D20101   Hardware Utility  Connection  1 2  2 2 dimensions  mounting  power supply wiring  specifications  and introduction to option JY997D20102   sold separately  devices  09R817      The manual in PDF format is included in the GT Works2 GT Designer2 GT Works3 GT Designer3 products   For details of a PLC to be connected  refer to the PLC user s manual respectively   Bundled Items   Product ee Bundled item Quantity   Specifications  Name       Operation switch name character sheets  1  OHP sheet  2  Reference dimension sheet  switch name change sheet    1  One sheet  2  One sheet    mount   Selector switch keys 2  GT11 Handy GOT General Description  This manual  1       1  Features  1  Improved monitoring performance and connectivity to FA devices      Two types of display modes are provided  256 color display and monochrome display  In the monochrome display  16 scales are used to improve the display     High speed monitoring through hi
13. 100 8310  JAPAN    
14. Dec    Year  example  2008   Last digit of year    e Battery life  Approximate battery life   5 years  ambient temperature  25  C   Battery replacement  In 4 to 5 years    Approximate life is 5 years  but life may be shorter depending on the ambient  temperature  therefore  note that the battery must be replaced in 4 to 5 years  Make  sure to purchase a new battery as needed as it self discharges     Battery status can be confirmed on a GOT utility screen   For details of battery status or how to output alarm  refer to the following       GT11 Handy GOT User   s Manual    5  Cautions on Using Emergency Stop Switch    1  When using the emergency stop switch in the handy GOT  judge the validity to  use the emergency stop switch in accordance with the risk assessment in your  system    2  When using the parallel circuit  which disables the emergency stop status while  the handy GOT is removed   the system may not conform to the safety  standards  Check the safety standards required in the system  and then judge  the validity to use the emergency stop switch     This manual confers no industrial property rights or any rights of any other  kind  nor does it confer any patent licenses  Mitsubishi Electric Corporation    cannot be held responsible for any problems involving industrial property rights  which may occur as a result of using the contents noted in this manual        Warranty   Mitsubishi will not be held liable for damage caused by factors found not to be  the cause of M
15. JY997D22801K    MITSUBISHI  ELECTRIC    GT1155HS QSBD  GT1150HS QLBD  GT11 Handy GOT General Description    GRAPHIC OPERATION TERMINAL Manual Number   JY997D22801K       This manual describes the part names  dimensions  mounting  and specifications  of the product  Before use  read this manual and manuals of relevant products  fully to acquire proficiency in handling and operating the product  Make sure to  learn all the product information  safety information  and precautions    And  store this manual in a safe place so that you can take it out and read it  whenever necessary  Always forward it to the end user    Registration   The company name and the product name to be described in this manual are the  registered trademarks or trademarks of each company     Effective April 2015  Specifications are subject to change without notice      2008 MITSUBISHI ELECTRIC CORPORATION    Safety Precaution  Read these precautions before using      Before using this product  please read this manual and the relevant manuals  introduced in this manual carefully and pay full attention to safety to handle the  product correctly    The precautions given in this manual are concerned with this product    In this manual  the safety precautions are ranked as  WARNING  and   CAUTION      Indicates that incorrect handling may cause hazardous   N WARNING conditions  resulting in death or severe injury     Indicates that incorrect handling may cause hazardous    CAUTION conditions  resulting in medium
16. Lit in orange    For the PC connection  refer to the following      6  7   Operation switch name sheet  prepared by the user   installation example    Specifications    Switch for external direct wiring  independent contact     Switch for external direct wiring  independent contact     Displays the utility screen and the user creation screen     For touch switch operation on the utility screen and the user creation screen   Place  concave shape  where the operation switch name sheet  created by user  is installed     Transparent cover to fix the operation switch name sheet  created by user   removed when a sheet is inserted    Display LED for grip switch  green   lighting control from display section     For external connection cable connection  for PLC  switch and power supply external wiring    connector  round 32 pins  male     Switch for external direct wiring  independent contact   Display LED for operation switch  green   lighting control from display section       Power is correctly supplied      Screen saving and backlight not lit   Blinks in orange green   Blown back light bulb    Not lit   Power is not supplied         GT11 Handy GOT User   s Manual    2 2 Back Panel    Environmental protection back cover closed     1   2   1                                                                                                                                   No     1     Specifications    Hook for mounting a   Hook for mounting a neck strap  must be prepared by  neck str
17. alarm  refer to the following       GT11 Handy GOT User   s Manual    This manual confers no industrial property rights or any rights of any other  kind  nor does it confer any patent licenses  Mitsubishi Electric Corporation    cannot be held responsible for any problems involving industrial property rights  which may occur as a result of using the contents noted in this manual        Warranty   Mitsubishi will not be held liable for damage caused by factors found not to be  the cause of Mitsubishi  opportunity loss or lost profits caused by faults in the  Mitsubishi products  damage  secondary damage  accident compensation  caused by special factors unpredictable by Mitsubishi  damages to products  other than Mitsubishi products  and to other duties     e This product has been manufactured as a general purpose part for general  industries  and has not been designed or manufactured to be incorporated in  a device or system used in purposes related to human life     e Before using the product for special purposes such as nuclear power  electric  power  aerospace  medicine or passenger movement vehicles  consult with  Mitsubishi Electric    e This product has been manufactured under strict quality control  However  when installing the product where major accidents or losses could occur if the  product fails  install appropriate backup or failsafe functions in the system        MITSUBISHI ELECTRIC CORPORATION    HEAD OFFICE   TOKYO BUILDING  2 7 3 MARUNOUCHI  CHIYODA KU  TOKYO 
18. ange   and the display section turns black and causes the monitor screen to appear  blank  while the input of the touch switch s  remains active    This may confuse an operator in thinking that the GOT is in  screensaver   mode  who then tries to release the GOT from this mode by touching the  display section  which may cause a touch switch to operate    Note that the following occurs on the GOT when the backlight goes out       The POWER LED flickers  green orange  and the monitor screen appears  blank             DESIGN PRECAUTIONS  NC AUTION    Do not bundle the control and communication cables with main circuit  power or  other wiring  Run the above cables separately from such wiring and keep them a  minimum of 100mm  3 94in   apart Not doing so noise can cause a malfunction   Do not press the GOT display section with a pointed material as a pen or driver   Doing so can result in a damage or failure of the display section    Before connecting to GOT  turn ON the controller to enable the communication   When the communication of controller is not available  a communication error  may occur in GOT     e Be sure to shut off all phases of the external power supply used by the system    before mounting or removing the GOT to from the panel    Not doing so can cause the unit to fail or malfunction    Always turn off the power ON OFF switch on the connector conversion box before  connecting or disconnecting the GOT to it    Connecting or disconnecting the GOT with the power bein
19. angeable  1 0A    Power consumption 9 84W  410mA 24V DC  or less 9 36W  390mA 24V DC  or less  At backlight off 4 32W  180mA 24V DC  or less    Inrush current 15A or less  26 4V  2ms    Item  GT1150HS QLBD    Input power supply voltage    Permissible instantaneous power    failure time 1 Within 5ms    Noise immunity Noise voltage  1000Vp p  Noise width  1us  by noise simulator of 30 to 100Hz noise frequency     Dielectric withstand voltage 500V AC for 1 minute  across power supply terminals and earth     Insulation resistance 10MQ or larger by insulation resistance tester  across power supply terminals and earth        The GOT continues to operate even upon 5ms or shorter instantaneous power failure   The GOT stops operating if there is extended power failure or voltage drop  while it automatically resumes operation as soon as the power is restored     3 4 External Dimensions    18  0 71   75  2 96       gt t  gt      72  2 84                        Unit  mm  inch           4  Maintenance and Inspection   The GOT does not include consumable components that will cause the shorten life   However  note that battery life is 5 years and LCD life is 50 000 hours  The life of  backlight in GT1155HS QSBD is 75 000 hours and that in GT1150HS QLBD is  54 000 hours    It is recommended to replace the battery periodically   For the replacement of the  liquid crystal screen and backlight  please consult your nearest sales office or FA  Center      4 1 Daily Inspection  Daily inspection it
20. ap the user     Hook for hanging on  walls     2  Hook when the Handy GOT is used hanging on walls     Environmental  protection back  cover screw    For opening and closing the environmental protection  back cover  drop prevention screw        Opened and closed when the PLC communication    type is changed  RS 422  lt  RS 232  before shipping   RS 422   the option function board is mounted  or the  battery is replaced     Used to hold the Handy GOT in hand by putting a  hand under the strap  Length adjustable     Environmental   4   protection back    cover        5    Hand strap    Model  consumption current  serial No   Hardware      6    Rating plate Firmware version is indicated      7    Grip switch Switch for external direct wiring  independent contact     3  Specifications  3 1 General Specifications    Item    Operating ambient Display section 0 to 40  C  temperature Other than Display section   0 to 40  C    Storage ambient temperature  20 to 60  C  Operating ambient humidity    Storage ambient humidity    Conforms to JIS  B3502 and    vibration    Vibration resistance    1IEC61131 2    vibration       Shock resistance  Operating atmosphere    Operating altitude    2000 m  6562 ft  max     Overvoltage category 2 II or less  Pollution degree s 2 or less  Cooling method Self cooling       Environmental protection back cover opened        14  Option function board installed    No Specifications     8    Battery holder GT11 50BAT type battery holder    GT11 50BAT type b
21. ar   To prevent heat damage  the screen saver function is effective   For details on the screen saver function  refer to the following       GT11 Handy GOT User s Manual     2 Using the GOT Backlight OFF function can prolong the life of the backlight   For details on the Backlight OFF function  refer to the following       GT11 Handy GOT User s Manual     3 ROM in which new data can be written without deleting the written data      4 Necessity of mounting the option function board may differ depending on the hardware version  Refer to the following for details       GT11 Handy GOT User   s Manual     5 Note that this does not guarantee all user   s operation environment  The protection is not applied when the interface environment protection cover or environment  protection back cover is removed  In addition  the product may not be used in environments under exposition of oil or chemicals for a long period of time  or in  environments filled with oil mist     3 3 Power Supply Specifications   Specifications  24V DC   10   15    ripple voltage 200mV or less  Fuse  built in  not exchangeable  1 0A    Power consumption 9 84W  410mA 24V DC  or less 9 36W  390mA 24V DC  or less  At backlight off 4 32W  180mA 24V DC  or less    Inrush current 15A or less  26 4V  2ms    Item  GT1150HS QLBD    Input power supply voltage    Permissible instantaneous power    failure time     Within 5ms    Noise immunity Noise voltage  1000Vp p  Noise width  1us  by noise simulator of 30 to 100Hz noise
22. attery  For storing clock data    4     Battery alarm history and recipe data     Connector for  battery connection     11    RS 232 interface     10  For GT11 50BAT type battery connection    Connector for PLC communication using RS 232        Interface cable connector for PLC communication   12  Cable connector for   Connector for either  11  or  13  and for selection of  PLC communication   the PLC communication type   Connected to RS 422   before shipping            13    RS 422 interface Connector for PLC communication using RS 422     14  Connector for option   Connector for mounting the GT11 50FNB type option  function board function board    For the connection to the controller  microcomputer board or PC  refer to the  following         GT11 Handy GOT User   s Manual    Specifications    10 to 90  RH  non condensing  The wet bulb temperature is 39  C or less      10 to 90  RH  non condensing  The wet bulb temperature is 39  C or less          Frequency     Acceleration     Half amplitude   Sweep Count  Under intermittent  St9H2       3sm      9 to 150Hz 9 8m s2    10 times each in X     Conforms to JIS B3502  IEC 61131 2  147 m s2  3 times each in X  Y and Z directions     Must be free of lamp black  corrosive gas  flammable gas  or excessive amount of electro conductive dust particles and  must be no direct sunlight   Same as for saving      1 Do not use or store the GOT under pressure higher than the atmospheric pressure of altitude Om  Oft    Failure to observe thi
23. d recipe data   Screen data is stored in the flash memory and data is retained even if the battery is  dead     e Battery model name  Handy GOT is shipped with the following battery          Product name Model name       GT11 50BAT    e Battery replacement procedure  1  Turn the GOT power off     2  Loosen the environmental protection back cover screws at four points on GOT  rear face to remove the cover     Environmental    sacra ot protection  ack cover back cover  screw screw    3  Remove the old battery from the holder     4  Disconnect the old battery connector and insert the new battery connector  within 30s     5  Insert the battery into the holder     Battery          Battery holder Connector for battery connection    6  Attach the environmental protection back cover and tighten the screws   Tightening torque  36 to 48 Ne cm  7  Turn the GOT power on   8  Check if the battery condition is normal with the utility   Refer to the following for the details of battery status display       GT11 Handy GOT User   s Manual    protection  back cover  screw    back cover  screw          Specifications  Item  GT1155HS QSBD    GT Designer2 Version2 15R or later GT Designer3 Version1 01B or later    GT1150HS QLBD  Compatible software package     1    Bright dots  always lit  and dark dots  unlit  may appear on a liquid crystal display panel  It is impossible to completely avoid this symptom  as the liquid crystal display  comprises of a great number of display elements  Flickers ma
24. e GT Designer3 installation operation  basic operation for drawing    and transmitting data to GOT1000 series    Describes specifications and settings of the object functions used in GT Designer3       STARTUP MAINTENANCE  PRECAUTIONS      CAUTION    e Do not disassemble or modify the unit   Doing so can cause a failure  malfunction  injury or fire    e Do not touch the conductive and electronic parts of the unit directly   Doing so can cause a unit malfunction or failure    e The cables connected to the unit must be run in ducts or clamped   Not doing so can cause the unit or cable to be damaged due to the dangling   motion or accidental pulling of the cables or can cause a malfunction due to a  cable connection fault   When unplugging the cable connected to the unit  do not hold and pull the cable  portion  Doing so can cause the unit or cable to be damaged or can cause a  malfunction due to a cable connection fault   Replace battery with GT11 50BAT by Mitsubishi electric Co  only   Use of another battery may present a risk of fire or explosion   Dispose of used battery promptly   Keep away from children  Do not disassemble and do not dispose of in fire     DISPOSAL PRECAUTIONS   CAUTION    e When disposing of the product  handle it as industrial waste    e When disposing of batteries  separate them from other wastes according to the  local regulations    For details of the battery directive in EU member states  refer GOT User s  Manual      TRANSPORTATION  PRECAUTIONS     
25. e sequence programs using the personal computer connected to GOT is available  during direct connection to A  QnA  L  Q  or FX series  PLC CPU  FA Transparent function      2  Part Name  2 1 Front Panel    een  eee     Cer re E                                                          F1 F2 F3 F4 F5 F6    ALO  ot     11   10   9   8           a1    6  7   Operation switch name sheet  prepared by the user   installation example     12      7                            g       No Specifications       1  Keylock switch  2 position SW  Switch for external direct wiring  independent contact     2  Emergency stop switch Switch for external direct wiring  independent contact     3  Logo  2 places  Removable    4  Display section Displays the utility screen and the user creation screen      5  Touch panel For touch switch operation on the utility screen and the user creation screen      6  Operation switch name sheet installation    place Place  concave shape  where the operation switch name sheet  created by user  is installed      7  Operation switch name sheet cover Transparent cover to fix the operation switch name sheet  created by user   removed when a sheet is inserted       8  Display LED for grip switch Display LED for grip switch  green   lighting control from display section   For external connection cable connection  for PLC  switch and power supply external wiring      9  External interface connector  connector  round 32 pins  male      10  Operation switch  6 switches  S
26. ed torque range   Undertightening can cause a short circuit or malfunction  Overtightening can    cause a short circuit or malfunction due to the damage of the screws or unit     TEST OPERATION    PRECAUTIONS   WARNING    e Before performing the test operations of the user creation monitor screen  such  as turning ON or OFF bit device  changing the word device current value   changing the settings or current values of the timer or counter  and changing the  buffer memory current value   read through the manual carefully and make  yourself familiar with the operation method    During test operation  never change the data of the devices which are used to  perform significant operation for the system  False output or malfunction can  cause an accident        STARTUP MAINTENANCE  PRECAUTIONS      WARNING       e When power is on  do not touch the terminals    Doing so can cause an electric shock or malfunction    e Connect the battery correctly  Do not discharge  disassemble  heat  short   solder or throw the battery into the fire  Incorrect handling may cause the battery  to generate heat  burst or take fire  resulting in injuries or fires    e Before starting cleaning or terminal screw retightening  always switch off the  power externally in all phases  Not switching the power off in all phases can  cause a unit failure or malfunction  Undertightening can cause a short circuit or  malfunction  Overtightening can cause a short circuit or malfunction due to the  damage of the scr
27. ee to which conductive material is generated in the environment where the equipment is used    In pollution degree 2  only non conductive pollution occurs but temporary conductivity may be produced due to condensation     3 2 Performance Specifications    Specifications    GT1155HS QSBD    Item  GT1150HS QLBD       STN color liquid crystal STN monochrome  white black  liquid crystal  Display size W115 4 53  x H86 3 39  mm  inch   Display Display character 16 dot standard font  20 characters x 15 lines  12 dot standard font  26 characters x 20 lines  section      Display color 256 colors Monochrome  white black   16 scales  Contrast adjustment 16 level adjustment  Intensity of LCD only 380 cd m2  Adjustable in 8 levels  220 cd m2  Adjustable in 8 levels   Intensity adjustment 8 level adjustment  Approx  50 000h   Time for display intensity to become 1 5 at operating ambient temperature of 25  C     Cold cathode fluorescent tube  irreplaceable by a user  backlight shutoff detection function is included   Backlight ae  Backlight off screen saving time can be set   Life 2 Approx  75 000h or longer  Time for display intensity reaches   Approx  54 000h or longer  Time for display intensity  50  at the operating ambient temperature of 25  C  reaches 50  at the operating ambient temperature of 25  C   Number of touch keys 300 keys screen  Matrix structure of 15 lines x 20 columns   Touch    panel Number of points touched Maximum of 2 points  simultaneously  1 million times or more  o
28. ems      Inspection eae      Inspection Item Method Action  Loose terminal Retghien Retighten    screws with Not loose    screwdriver    Proximate   Proper   solderless terminals vispal ongck Poon  Retighten   Visual check Not loose connector fixing  screws   Dirt on protection  gt  Not Replace with   Vistaleneck outstanding new one   Foreign material   No foreign   attachment Miavalcheck matter sticking REMOVE ora    Refer to the following for the model names of the protection sheet or the  replacement procedure     screws terminal screws    o  5         g  D  c  2  5  O  D  f    f     e   O    Loose connectors    Usage status           GT11 Handy GOT User   s Manual  4 2 Periodic Inspection    Yearly or half yearly inspection items  The following inspection should also be performed when equipment has been  moved or modified or the wiring changed       Inspection E  No  Inspection Item Method  Ambient Make Ot 5  o 40  C i  measurement oes in control  ith  Surrounding   Ambient iid n temperature  i environment   humidity Aa Ge ii inside control  e e m   panel is ambient  o corrosive  Atmosphere   corrosive gas temperature  24V DC  Measure 20 4 to 26 4V   Change supply  voltage across  DC power  terminals   Should be  Looseness  Move module  mounted  firmly  3 No dirt   Dirt  foreign      foreign  matter Misvalcneck matter  sticking  Retighten      screws with Not loose sa i terminal  screwdriver    Proper  solderless  Visual check     Loose    connectors Visual check   Not lo
29. eration switch display   6 LEDs  green  lighting control from the display section   LED for grip switch display 1 LED  green  lighting control from display unit part   Battery GT11 50BAT lithium battery  Magnesium maganese dioxide lithium primary battery  Backup target Clock data  alarm history and recipe data  Approx  5 years  Operating ambient temperature of 25  C   Guaranteed  1 year  RS422 RS232 1ch  Transmission speed   115 200 57 600 38 400 19 200 9 600 4 800bps  or eer gee Connector shape   Round 32 pins  male   Application   PLC communication  Select either RS 422 or RS 232 when used   RS232 1ch  RS 232 Transmission speed   115 200 57 600 38 400 19 200 9 600 4 800bps  Connector shape   MINI DIN 6 pin  Female   Built in Application   PC communication  Project data upload download  OS installation  transparent function   InteHace USB  Full Speed 12Mbps  1ch  USB Connector shape  Mini B  Application   PC communication  Project data upload download  OS installation  transparent function     Conforming to PCMCIA  compact flash slot  1ch  Connector shape   Dedicated for TYPE I  Application   Data transfer  data storage    CF card    Option function board 4 For mounting the option function board  1ch  Equivalent to IP65F  excluded on the relay connector side of external cable valid when the external cable is connected   W176  6 93  x H220  8 67  x D93 3 67   mm   inch     1 0kg  Handy GOT main unit only     Environmental protective structure 5  External dimensions  Weight   
30. ews or unit        Associated Manuals       STARTUP MAINTENANCE  PRECAUTIONS      CAUTION    e Do not disassemble or modify the unit   Doing so can cause a failure  malfunction  injury or fire    e Do not touch the conductive and electronic parts of the unit directly   Doing so can cause a unit malfunction or failure    e The cables connected to the unit must be run in ducts or clamped   Not doing so can cause the unit or cable to be damaged due to the dangling   motion or accidental pulling of the cables or can cause a malfunction due to a  cable connection fault   When unplugging the cable connected to the unit  do not hold and pull the cable  portion  Doing so can cause the unit or cable to be damaged or can cause a  malfunction due to a cable connection fault   Replace battery with GT11 50BAT by Mitsubishi electric Co  only   Use of another battery may present a risk of fire or explosion   Dispose of used battery promptly   Keep away from children  Do not disassemble and do not dispose of in fire     DISPOSAL PRECAUTIONS   CAUTION    e When disposing of the product  handle it as industrial waste    e When disposing of batteries  separate them from other wastes according to the  local regulations    For details of the battery directive in EU member states  refer GOT User s  Manual      TRANSPORTATION  PRECAUTIONS      CAUTION    e When transporting lithium batteries  make sure to treat them based on the  transport regulations   Refer to User s Manual for details of the reg
31. g turned on may result  in damage to the unit or malfunctions    Be sure to shut off all phases of the external power supply used by the system  before mounting or removing the relay cable onto from the GOT    Be sure to shut off all phases of the external power supply used by the system  before mounting or removing the option function board on to from the GOT  Not  doing so can cause the unit to fail or malfunction    When installing the option function board or battery  or operating the reset switch   wear an earth band etc  to avoid the static electricity    The static electricity can cause the unit to fail or malfunction     e Use the GOT in the environment that satisfies the general specifications    described in this manual  Not doing so can cause an electric shock  fire   malfunction or product damage or deterioration    Never drop cutting chips and electric wire chips into the ventilation window of the  Handy GOT when you drill screw holes or perform wiring    Otherwise  fire  failure or malfunction may be caused    Connect connection cables securely to the specified connectors while the power  is turned OFF    Imperfect connection may cause malfunction or failure    When connecting cables  pay attention to the contents described in this section   Especially  attach the rear cover so that PCBs inside the Handy GOT are not  interfered with connection cables    Securely connect the option function board to the connector provided for the  board    When inserting removing
32. gh speed communication at maximum of 115 2kbps     Multiple languages are displayed using the Unicode2 1 compatible fonts and beautiful characters are drawn using the TrueType and high quality fonts       High speed display and high speed touch switch response     2  More efficient GOT operations including screen design  startup  adjustment  management and maintenance works    The display screen of the display unit is created using a drawing software for PC  GT Designer2 Ver2 18U or later GT Designer3 Ver1 01B or later        The 3MB user memory is included as standard      CF card interface is included as standard      The USB connector interface is included as standard   3  Enhanced support of FA device setup tools      Transferring or monitoring the sequence programs using the personal computer connected to GOT is available  during direct connection to A  QnA  L  Q  or FX series    PLC CPU  FA Transparent function      2  Part Name  2 1 Front Panel                                            12                                          11   10   9   8     No     1  Keylock switch  2 position SW    2  Emergency stop switch    3  Logo  2 places  Removable   4  Display section   5  Touch panel     6  Operation switch name sheet installation  place     7  Operation switch name sheet cover     8  Display LED for grip switch     9  External interface connector     10  Operation switch  6 switches    11  Display LED for operation switch  6 LEDs     Lit in green     12    POWER LED 
33. ing the reset switch   wear an earth band etc  to avoid the static electricity   The static electricity can cause the unit to fail or malfunction     e Use the GOT in the environment that satisfies the general specifications  described in this manual  Not doing so can cause an electric shock  fire   malfunction or product damage or deterioration    Never drop cutting chips and electric wire chips into the ventilation window of the  Handy GOT when you drill screw holes or perform wiring    Otherwise  fire  failure or malfunction may be caused    Connect connection cables securely to the specified connectors while the power  is turned OFF    Imperfect connection may cause malfunction or failure    When connecting cables  pay attention to the contents described in this section   Especially  attach the rear cover so that PCBs inside the Handy GOT are not  interfered with connection cables    Securely connect the option function board to the connector provided for the  board    When inserting removing a CF card into from the GOT  turn the CF card access  switch off in advance  Failure to do so may corrupt data within the CF card    When inserting a CF card into the GOT  push it into the insertion slot until the CF  card eject button will pop out  Failure to do so may cause a malfunction due to  poor contact    When removing a CF card from the GOT  make sure to support the CF card by  hand  as it may pop out  Failure to do so may cause the CF card to drop from the  GOT and break   
34. it or cable to be damaged due to the dangling   motion or accidental pulling of the cables or can cause a malfunction due to a  cable connection fault   When unplugging the cable connected to the unit  do not hold and pull the cable  portion   Doing so can cause the unit or cable to be damaged or can cause a malfunction  due to a cable connection fault     Plug the communication cable into the connector of the connected unit and  tighten the mounting and terminal screws in the specified torque range   Undertightening can cause a short circuit or malfunction  Overtightening can    cause a short circuit or malfunction due to the damage of the screws or unit     TEST OPERATION    PRECAUTIONS   WARNING    e Before performing the test operations of the user creation monitor screen  such  as turning ON or OFF bit device  changing the word device current value   changing the settings or current values of the timer or counter  and changing the  buffer memory current value   read through the manual carefully and make  yourself familiar with the operation method    During test operation  never change the data of the devices which are used to  perform significant operation for the system  False output or malfunction can  cause an accident        STARTUP MAINTENANCE  PRECAUTIONS      WARNING       e When power is on  do not touch the terminals    Doing so can cause an electric shock or malfunction    e Connect the battery correctly  Do not discharge  disassemble  heat  short   solder or 
35. itsubishi  opportunity loss or lost profits caused by faults in the  Mitsubishi products  damage  secondary damage  accident compensation  caused by special factors unpredictable by Mitsubishi  damages to products  other than Mitsubishi products  and to other duties     e This product has been manufactured as a general purpose part for general  industries  and has not been designed or manufactured to be incorporated in  a device or system used in purposes related to human life     e Before using the product for special purposes such as nuclear power  electric  power  aerospace  medicine or passenger movement vehicles  consult with  Mitsubishi Electric     e This product has been manufactured under strict quality control  However  when installing the product where major accidents or losses could occur if the  product fails  install appropriate backup or failsafe functions in the system     MITSUBISHI ELECTRIC CORPORATION    HEAD OFFICE   TOKYO BUILDING  2 7 3 MARUNOUCHI  CHIYODA KU  TOKYO 100 8310  JAPAN       JY997D22801K    MITSUBISHI  ELECTRIC    GT1155HS QSBD  GT1150HS QLBD  GT11 Handy GOT General Description    GRAPHIC OPERATION TERMINAL Manual Number   JY997D22801K       This manual describes the part names  dimensions  mounting  and specifications  of the product  Before use  read this manual and manuals of relevant products  fully to acquire proficiency in handling and operating the product  Make sure to  learn all the product information  safety information  and preca
36. n     Half amplitude   Sweep Count   Under intermittent  Sto9Hz       35mm     etal 9to150Hz   8 8mist  _  10 times each in x  Y and Z directions   Under continuous  Saa J     Memm   a wem p a a    Conforms to JIS B3502  IEC 61131 2  147 m s2  3 times each in X  Y and Z directions     Conforms to JIS    Vibration resistance B3502 and    IEC61131 2       Shock resistance    Must be free of lamp black  corrosive gas  flammable gas  or excessive amount of electro conductive dust particles and    Operating amosphere must be no direct sunlight   Same as for saving     Operating altitude     2000 m  6562 ft  max     Overvoltage category 2 II or less  Pollution degree 3 2 or less  Cooling method Self cooling     1 Do not use or store the GOT under pressure higher than the atmospheric pressure of altitude Om  Oft    Failure to observe this instruction may cause a malfunction   When the air inside the control panel is purged by pressurization  the surface sheet may be lifted by high pressure  As a result  the touch panel may be difficult to press   and the sheet may be peeled off     2 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the  machinery within the premises  Category II applies to equipment for which electrical power is supplied from fixed facilities  The surge voltage withstand level for up to the  raged voltage of 300 V is 2500 V     3 This index indicates the degr
37. ndard font  20 characters x 15 lines  12 dot standard font  26 characters x 20 lines  16 level adjustment  Zajeamayagustabe 8 eves  8 level adjustment  Approx  50 000h   Time for display intensity to become 1 5 at operating ambient temperature of 25  C   Backlight Backlight off screen saving time can be set   300 keys screen  Matrix structure of 15 lines x 20 columns   Minimum 16 x 16 dots  per key   Touch    panel Maximum of 2 points  1 million times or more  operating force 0 98N max    Flash memory  Internal   for storing project data  3Mbytes  and OS  memar a of write times  TOU OOO MINES    D drive    Internal clock   Accuracy    Buzzer output Single tone  tone length adjustable     Operation switch    Grip switch    times          SRAM  Internal   512kbyes  battery backup    45 seconds   45 seconds per month    6 switches  6 contacts common   N O contact  Maximum rating 10mA 24VDC  Life  1 000 000 times    1 switch  single wiring   IDEC HE3B M2PB   Enable switch  deadman switch  3 position system of OFF  lt  gt  ON  lt  gt  OFF  2 N O contacts  Maximum rating 1A 24VDC  resistance load   Maximum rating 0 3A 24VDC  induction load   Life  100 000    1 switch  single wiring   OMRON A165E S 02   2 N C contacts  Maximum rating 1A 24VDC  resistance load   Maximum rating 0 3A 24VDC  induction load   Life  100 000    2 notch type  Manual stop at each position A key can be inserted and removed on only the left side  On the right side  a key    2 position  Maximum rating 1A 24VDC 
38. nvironmental temperature   Especially in the low temperature environment  the display response becomes slow due to the characteristics of the STN liquid crystal   Please check the display response in advance for using this product       When the same screen is displayed for a long time  an incidental color or partial discoloration is generated on the screen due to heat damage  and it may not disappear   To prevent heat damage  the screen saver function is effective   For details on the screen saver function  refer to the following       GT11 Handy GOT User s Manual     2 Using the GOT Backlight OFF function can prolong the life of the backlight   For details on the Backlight OFF function  refer to the following       GT11 Handy GOT User s Manual     3 ROM in which new data can be written without deleting the written data      4 Necessity of mounting the option function board may differ depending on the hardware version  Refer to the following for details       GT11 Handy GOT User   s Manual     5 Note that this does not guarantee all user   s operation environment  The protection is not applied when the interface environment protection cover or environment  protection back cover is removed  In addition  the product may not be used in environments under exposition of oil or chemicals for a long period of time  or in  environments filled with oil mist     3 3 Power Supply Specifications   Specifications  24V DC   10   15    ripple voltage 200mV or less  Fuse  built in  not exch
39. on    MADE IN JAPAN     Actual product nameplate differs  from the example shown above     7 digit  lt Dec   2009 or before gt      1   0   4   0  fo  loh  ponnn      L Control number  Month  example  Jan      L Control number  1 to 9  Jan  to Sep   Month  example  Oct     X  Oct   Y  Nov   Z  Dec                  lt Jan   2010 or later gt        1 to 9  Jan  to Sep     X  Oct   Y  Nov   Z  Dec   Year  example  2009   Last digit of year    Year  example  2010   Last two digit of year    The production date of the optional replacement battery can be confirmed by the lot  No  marked on the nameplate  label  affixed on the battery        Nameplate  Connector  Model name T11 50BAT  LOT  LOT 101              lt Jan   2010 or later gt   lt Dec   2009 or before gt     3 digit 2 digit  Ho   x    T Month  T Month   example  Jan    example  Oct    1  Jan   to 9  Sep    1  Jan   to 9  Sep     X  Oct    Y  Nov    Z  Dec   X  Oct    Y  Nov    Z  Dec    Year  example  2010  Year  example  2008   Last two digit of year Last digit of year  e Battery life    Approximate battery life   5 years  ambient temperature  25  C   Battery replacement  In 4 to 5 years    Approximate life is 5 years  but life may be shorter depending on the ambient  temperature  therefore  note that the battery must be replaced in 4 to 5 years  Make  sure to purchase a new battery as needed as it self discharges     Battery status can be confirmed on a GOT utility screen   For details of battery status or how to output 
40. ose    Check the  system alarm    Action       2 Power supply voltage  check    Retighten screws    Remove  clean    4 Connection Proximate    stat  s Correct    Retighten  connector fixing  screws    Replace with new  battery when the    current battery   5 Se on  Preventive  has reached the  the Alarm maintenance    specified life span   Information even if battery  Screen voltage is not   displayed     4 3 Battery Replacement    The battery backs up clock data  alarm history and recipe data   Screen data is stored in the flash memory and data is retained even if the battery is  dead     e Battery model name  Handy GOT is shipped with the following battery         Product name Model name       GT11 50BAT    e Battery replacement procedure  1  Turn the GOT power off     2  Loosen the environmental protection back cover screws at four points on GOT  rear face to remove the cover         Environmental      Ng   dean    protection  ack cover back cover   screw screw    3  Remove the old battery from the holder     4  Disconnect the old battery connector and insert the new battery connector  within 30s     5  Insert the battery into the holder     Battery          Battery holder Connector for battery connection    6  Attach the environmental protection back cover and tighten the screws   Tightening torque  36 to 48 Ne cm  7  Turn the GOT power on   8  Check if the battery condition is normal with the utility   Refer to the following for the details of battery status display     
41. perating force 0 98N max    Flash memory  Internal   for storing project data  3Mbytes  and OS  Life      Memely  Number of write times  TOG OOO MINES    D drive SRAM  Internal   512kbyes  battery backup      45 seconds   45 seconds per month    Internal clock   Accuracy    Single tone  tone length adjustable   6 switches  6 contacts common   N O contact  Maximum rating 10mA 24VDC  Life  1 000 000 times    Buzzer output    Operation switch    1 switch  single wiring   IDEC HE3B M2PB   Enable switch  deadman switch  3 position system of OFF  lt  gt  ON  lt  gt  OFF  2 N O contacts  Maximum rating 1A 24VDC  resistance load   Maximum rating 0 3A 24VDC  induction load   Life  100 000  times    1 switch  single wiring   OMRON A165E S 02     Grip switch          Switch Emergency stop switch 2 N C contacts  Maximum rating 1A 24VDC  resistance load   Maximum rating 0 3A 24VDC  induction load   Life  100 000  times  1 switch  single wiring   IDEC AS6Q 2KT1PB   Keylock switch 2 notch type  Manual stop at each position A key can be inserted and removed on only the left side  On the right side  a key   2 position switch  cannot be removed  Two keys are provided    2 position  Maximum rating 1A 24VDC  resistance load   Maximum rating 0 3A 24VDC  induction load   Life  100 000 times  1 LED  Lit in green  Power is correctly supplied   POWER LED Lit in orange  Screen saving and backlight not lit   LED Blinks in orange green  Blown back light bulb   Not lit  Power is not supplied   LED for op
42. s instruction may cause a malfunction   When the air inside the control panel is purged by pressurization  the surface sheet may be lifted by high pressure  As a result  the touch panel may be difficult to press     and the sheet may be peeled off      2 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the  machinery within the premises  Category II applies to equipment for which electrical power is supplied from fixed facilities  The surge voltage withstand level for up to the    raged voltage of 300 V is 2500 V      3 This index indicates the degree to which conductive material is generated in the environment where the equipment is used   In pollution degree 2  only non conductive pollution occurs but temporary conductivity may be produced due to condensation     3 2 Performance Specifications    Item    GT1155HS QSBD  STN color liquid crystal STN monochrome  white black  liquid crystal    Specifications  GT1150HS QLBD    256 colors Monochrome  white black   16 scales    Cold cathode fluorescent tube  irreplaceable by a user  backlight shutoff detection function is included     Life 2 Approx  75 000h or longer  Time for display intensity reaches   Approx  54 000h or longer  Time for display intensity  50  at the operating ambient temperature of 25  C  reaches 50  at the operating ambient temperature of 25  C        W115 4 53  x H86 3 39  mm  inch   Display 16 dot sta
43. t 1 0kg  Handy GOT main unit only        4  Maintenance and Inspection   The GOT does not include consumable components that will cause the shorten life   However  note that battery life is 5 years and LCD life is 50 000 hours  The life of  backlight in GT1155HS QSBD is 75 000 hours and that in GT1150HS QLBD is  54 000 hours    It is recommended to replace the battery periodically   For the replacement of the  liquid crystal screen and backlight  please consult your nearest sales office or FA  Center      4 1 Daily Inspection    Daily inspection items      Inspection ye    i Inspection Item Method Action  Loose terminal Pana Retighten    screws with Not loose    screwdriver    Proximate   Proper   solderless terminals visual emedk Conect  Retighten   Visual check Not loose connector fixing  screws   Dirt on protection   Not Replace with   yiatalpheck outstanding new one   Foreign material   No foreign   attachment Misvalcneck matter sticking omevercieay    Refer to the following for the model names of the protection sheet or the  replacement procedure     screws terminal screws     a  5         s  7   c  2  5  O   cb   fa  fa  je   O    Loose connectors    Usage status           GT11 Handy GOT User   s Manual  4 2 Periodic Inspection    Yearly or half yearly inspection items  The following inspection should also be performed when equipment has been  moved or modified or the wiring changed     No  Inspection Item cere ea  Ambient Make Ot     o 40  C    measurement ade i in con
44. the monitor screen appears  blank          DESIGN PRECAUTIONS  NC AUTION    Do not bundle the control and communication cables with main circuit  power or  other wiring  Run the above cables separately from such wiring and keep them a  minimum of 100mm  3 94in   apart Not doing so noise can cause a malfunction   Do not press the GOT display section with a pointed material as a pen or driver   Doing so can result in a damage or failure of the display section    Before connecting to GOT  turn ON the controller to enable the communication   When the communication of controller is not available  a communication error  may occur in GOT     e Be sure to shut off all phases of the external power supply used by the system  before mounting or removing the GOT to from the panel   Not doing so can cause the unit to fail or malfunction   Always turn off the power ON OFF switch on the connector conversion box before  connecting or disconnecting the GOT to it   Connecting or disconnecting the GOT with the power being turned on may result  in damage to the unit or malfunctions   Be sure to shut off all phases of the external power supply used by the system  before mounting or removing the relay cable onto from the GOT   Be sure to shut off all phases of the external power supply used by the system  before mounting or removing the option function board on to from the GOT  Not  doing so can cause the unit to fail or malfunction   When installing the option function board or battery  or operat
45. throw the battery into the fire  Incorrect handling may cause the battery  to generate heat  burst or take fire  resulting in injuries or fires    e Before starting cleaning or terminal screw retightening  always switch off the  power externally in all phases  Not switching the power off in all phases can  cause a unit failure or malfunction  Undertightening can cause a short circuit or  malfunction  Overtightening can cause a short circuit or malfunction due to the  damage of the screws or unit        Associated Manuals  The following manuals are relevant to this product  When these loose manuals are required  please consult with our local distributor     Contents Manual Number   Model Code     Manual name    GT Designer2 Version2 Basic Operation Data  Transfer Manual  For GOT1000 Series    sold separately   1    GT Designer2 Version2 Screen Design Manual   For GOT1000 Series  1 3  2 3  3 3   sold separately   1    GT Designer3 Version1 Screen Design Manual   For GOT1000 Series   Fundamentals  1 2  2 2   sold separately   1    GT Designer3 Version1 Screen Design Manual   For GOT1000 Series   Functions  1 2  2 2   sold separately   1    GT11 Handy GOT User   s Manual   Hardware Utility  Connection  1 2  2 2   sold separately  devices    Describes methods of the GT Designer2 installation operation  basic operation for drawing  and transmitting data to GOT1000 series    Describes specifications and settings of the object functions used in GT Designer2    Describes methods of th
46. trol    7 ith    Surrounding   Ambient ne    temperature    environment   humidity pea hala 10 to 304RkI inside control  ca F   panel is ambient  o corrosive  Atmosphere   corrosive gas temperature    24V DC  2 Power supply voltage Measure 20 4 to 26 4V  Change supply  check voltage across   DC power  terminals   Should be  Looseness  Move module  mounted  firmly  3 No dirt   Dirt  foreign      foreign  matter Visual check matter  sticking  Retighten r    screws with Not loose pis ea terminal  screwdriver  f Proper  solderless  Visual check     Loose    connectors Visual check   Not loose    Check the  system alarm   error code    5 500  report on  the Alarm  Information  screen    Action       Retighten screws    Remove  clean    4 Connection Proximate    status Correct    Retighten  connector fixing  screws    Replace with new  battery when the  current battery  has reached the     Preventive  maintenance    specified life span   even if battery  voltage is not  displayed       PC communication  Project data upload download  OS installation  transparent function     Conforming to PCMCIA  compact flash slot  1ch  Connector shape   Dedicated for TYPE I    Data transfer  data storage    For mounting the option function board  1ch  Equivalent to IP65F  excluded on the relay connector side of external cable valid when the external cable is connected   W176  6 93  x H220  8 67  x D93 3 67   mm   inch     4 3 Battery Replacement    The battery backs up clock data  alarm history an
47. urated  models      Before transporting the GOT  turn the GOT power on and check that the battery  voltage status is normal on the Time setting  amp  display screen  utilities screen   In  addition  confirm that the adequate battery life remains on the rating plate   Transporting the GOT with the low battery voltage or the battery the reached  battery life may unstabilize the backup data unstable during transportation   Make sure to transport the GOT main unit and or relevant unit s  in the manner  they will not be exposed to the impact exceeding the impact resistance  described in the general specifications of this manual  as they are precision  devices  Failure to do so may cause the unit to fail    Check if the unit operates correctly after transportation     The following manuals are relevant to this product  When these loose manuals are required  please consult with our local distributor     Manual name    GT Designer2 Version2 Basic Operation Data  Transfer Manual  For GOT1000 Series    sold separately   1    GT Designer2 Version2 Screen Design Manual   For GOT1000 Series  1 3  2 3  3 3   sold separately   1    GT Designer3 Version1 Screen Design Manual   For GOT1000 Series   Fundamentals  1 2  2 2   sold separately   1    GT Designer3 Version1 Screen Design Manual   For GOT1000 Series   Functions  1 2  2 2    Describes methods of the GT Designer2 installation operation  basic operation for drawing  and transmitting data to GOT1000 series    Describes specifications and
48. utions    And  store this manual in a safe place so that you can take it out and read it  whenever necessary  Always forward it to the end user    Registration   The company name and the product name to be described in this manual are the  registered trademarks or trademarks of each company     Effective April 2015  Specifications are subject to change without notice      2008 MITSUBISHI ELECTRIC CORPORATION    Safety Precaution  Read these precautions before using      Before using this product  please read this manual and the relevant manuals  introduced in this manual carefully and pay full attention to safety to handle the  product correctly    The precautions given in this manual are concerned with this product    In this manual  the safety precautions are ranked as  WARNING  and   CAUTION      Indicates that incorrect handling may cause hazardous   N WARNING conditions  resulting in death or severe injury     Indicates that incorrect handling may cause hazardous    CAUTION conditions  resulting in medium or slight personal injury  or physical damage   Depending on circumstances  procedures indicated by  CAUTION  may also be    linked to serious results   In any case  it is important to follow the directions for usage     DESIGN PRECAUTIONS   WARNING    e Some failures of the GOT or cable may keep the outputs on or off   An external monitoring circuit should be provided to check for output signals  which may lead to a serious accident   Not doing so can cause an accident
49. witch for external direct wiring  independent contact      11  Display LED for operation switch  6 LEDs    Display LED for operation switch  green   lighting control from display section     Lit in green   Power is correctly supplied    Lit in orange   Screen saving and backlight not lit   Blinks in orange green   Blown back light bulb    Not lit   Power is not supplied      12    POWER LED    For the PC connection  refer to the following       GT11 Handy GOT User   s Manual    2 2 Back Panel    Environmental protection back cover closed Environmental protection back cover opened    Pe        0          YO      LT ler   e I   3       3   ONY me r O         7   gt                                                                                             14  Option function board installed                         O  HQS                      Specifications    Specifications    op ne    Hook for mounting a   Hook for mounting a neck strap  must be prepared by  8    Battery holder GT11 50BAT type battery holder    nee meee    9    Batte GT11 50BAT type battery  For storing clock data   y alarm history and recipe data      10  a r  For GT11 50BAT type battery connection    Hook for hanging on    walls Hook when the Handy GOT is used hanging on walls     N       Environmental  protection back  cover screw    For opening and closing the environmental protection    back cover  drop prevention screw   11    RS 232 interface Connector for PLC communication using RS 232        Interface
50. y be observed depending on the display color   Please note that these dots appear due to its characteristic and are not caused by product defect     e Flickers and partial discoloration may be generated on the liquid crystal display panel due to the display contents or the contrast adjustment  However  please note  that these phenomena appear due to its characteristic and are not caused by product defect     e There is a difference in the display brightness and the color tones between liquid crystal display panels  When using multiple liquid crystal display panels  please note  that there is an individual difference between them     e A crosstalk  shadow as an extension of the display  may appear on the liquid crystal display panel  Please note that it appears due to its characteristic    e When the display section is seen from the outside of the display angle  the display color seems like it has changed  Please note that it is due to its characteristic   Please note that the response time  brightness and color of the liquid crystal display panel may vary depending on the usage environmental temperature   Especially in the low temperature environment  the display response becomes slow due to the characteristics of the STN liquid crystal    Please check the display response in advance for using this product        When the same screen is displayed for a long time  an incidental color or partial discoloration is generated on the screen due to heat damage  and it may not disappe
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
  Uso de la Utilidad de configuración de recursos  MANUAL DE USUARIO DE LA SECRETARÍA VIRTUAL ESCUELA  Bedienungs- und Aufstellanleitung Fireplace user - Migros  Instruction Manual  Installation Manual - SMA INVERTER MANAGER / SMA DIGITAL I/O  Sunbeam Bedding SCH2100 User's Manual  Bluetooth Audio Cube User Guide New June09.indd  Samsung Galaxy Tab 7.0 Plus User Manual  détails types - Canam International    Copyright © All rights reserved. 