Home
JY997D22801-K - Mitsubishi Electric
Contents
1. Specifications Item GT1155HS QSBD GT Designer2 Version2 15R or later GT Designer3 Version1 01B or later GT1150HS QLBD Compatible software package 1 Bright dots always lit and dark dots unlit may appear on a liquid crystal display panel It is impossible to completely avoid this symptom as the liquid crystal display comprises of a great number of display elements Flickers may be observed depending on the display color Please note that these dots appear due to its characteristic and are not caused by product defect e Flickers and partial discoloration may be generated on the liquid crystal display panel due to the display contents or the contrast adjustment However please note that these phenomena appear due to its characteristic and are not caused by product defect e There is a difference in the display brightness and the color tones between liquid crystal display panels When using multiple liquid crystal display panels please note that there is an individual difference between them e A crosstalk shadow as an extension of the display may appear on the liquid crystal display panel Please note that it appears due to its characteristic e When the display section is seen from the outside of the display angle the display color seems like it has changed Please note that it is due to its characteristic Please note that the response time brightness and color of the liquid crystal display panel may vary depending on the usage e
2. GT11 Handy GOT User s Manual protection back cover screw back cover screw e How to confirm production year and month The production year and month of the battery built in the purchased GOT can be confirmed by the production No S N marked on the GOT main unit Example nameplate manufacture s serial number 1010001 GRAPHIC OPERATION TERMINAL MODEL GT1155HS QSBD IN 20 4 26 4VDC POWER 9 84W MAX SIN 1010001 AJ AJ MITSUBISHI ELECTRIC CORPORATION Hardware version MADE IN JAPAN Actual product nameplate differs from the example shown above lt Dec 2009 or before gt 6 digit 9 x o o fo L Control number Month example Oct 1 to 9 Jan to Sep X Oct Y Nov Z Dec Year example 2009 Last digit of year lt Jan 2010 or later gt 7 digit 1 fo 4 lollo 0 1 Control number Month example Jan 1 to 9 Jan to Sep X Oct Y Nov Z Dec Year example 2010 Last two digit of year The production date of the optional replacement battery can be confirmed by the lot No marked on the nameplate label affixed on the battery Nameplate Connector Model name T11 50BAT LOT LOT 101 lt Jan 2010 or later gt 8i X L Month example Jan 1 Jan to 9 Sep X Oct Y Nov Z Dec Year example 2010 Last two digit of year example Oct 1 Jan to 9 Sep X Oct Y Nov Z
3. Make sure to attach the back cover to the Handy GOT before turning on the power and starting operation after the installation or wiring work Otherwise electrical shock may be caused Be sure to shut off all phases of the external power supply used by the system before wiring Failure to do so may result in an electric shock product damage or malfunctions Please make sure to ground FG terminal of the GOT power supply section by applying 100 or less which is used exclusively for the GOT Not doing so may cause an electric shock or malfunction Correctly wire the GOT power supply section after confirming the rated voltage and terminal arrangement of the product Not doing so can cause a fire or failure Exercise care to avoid foreign matter such as chips and wire offcuts entering the GOT Not doing so can cause a fire failure or malfunction WIRING PRECAUTIONS c AUTION e The cables connected to the unit must be run in ducts or clamped Not doing so can cause the unit or cable to be damaged due to the dangling motion or accidental pulling of the cables or can cause a malfunction due to a cable connection fault When unplugging the cable connected to the unit do not hold and pull the cable portion Doing so can cause the unit or cable to be damaged or can cause a malfunction due to a cable connection fault Plug the communication cable into the connector of the connected unit and tighten the mounting and terminal screws in the specifi
4. CAUTION e When transporting lithium batteries make sure to treat them based on the transport regulations Refer to User s Manual for details of the regurated models Before transporting the GOT turn the GOT power on and check that the battery voltage status is normal on the Time setting amp display screen utilities screen In addition confirm that the adequate battery life remains on the rating plate Transporting the GOT with the low battery voltage or the battery the reached battery life may unstabilize the backup data unstable during transportation Make sure to transport the GOT main unit and or relevant unit s in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of this manual as they are precision devices Failure to do so may cause the unit to fail Check if the unit operates correctly after transportation SH 080529ENG 1D7M24 SH 080530ENG 1D7M25 SH 080866ENG 1D7MB9 SH 080867ENG The manual in PDF format is included in the GT Works2 GT Designer2 GT Works3 GT Designer3 products For details of a PLC to be connected refer to the PLC user s manual respectively Bundled Items Product Model Name Name GT1155HS 320 x 240 dots STN color LCD 256 colors built in QSBD battery and backlight GT1150HS 320 x 240 dots STN monochrome LCD black white 16 QLBD scales built in battery and backlight Specifications
5. GOT 1D7MC1 Describes the Handy GOT hardware relevant content such as part names external JY997D20101 dimensions mounting power supply wiring specifications and introduction to option JY997D20102 09R817 Bundled item Quantity Operation switch name character sheets 1 OHP sheet 2 Reference dimension sheet switch name change sheet mount 1 One sheet 2 One sheet Selector switch keys 2 GT11 Handy GOT General Description This manual 1 1 Features 1 Improved monitoring performance and connectivity to FA devices Two types of display modes are provided 256 color display and monochrome display In the monochrome display 16 scales are used to improve the display High speed monitoring through high speed communication at maximum of 115 2kbps Multiple languages are displayed using the Unicode2 1 compatible fonts and beautiful characters are drawn using the TrueType and high quality fonts High speed display and high speed touch switch response 2 More efficient GOT operations including screen design startup adjustment management and maintenance works The display screen of the display unit is created using a drawing software for PC GT Designer2 Ver2 18U or later GT Designer3 Ver1 01B or later The 3MB user memory is included as standard CF card interface is included as standard The USB connector interface is included as standard 3 Enhanced support of FA device setup tools Transferring or monitoring th
6. a CF card into from the GOT turn the CF card access switch off in advance Failure to do so may corrupt data within the CF card When inserting a CF card into the GOT push it into the insertion slot until the CF card eject button will pop out Failure to do so may cause a malfunction due to poor contact When removing a CF card from the GOT make sure to support the CF card by hand as it may pop out Failure to do so may cause the CF card to drop from the GOT and break Make sure to attach the back cover to the Handy GOT before turning on the power and starting operation after the installation or wiring work Otherwise electrical shock may be caused Be sure to shut off all phases of the external power supply used by the system before wiring Failure to do so may result in an electric shock product damage or malfunctions Please make sure to ground FG terminal of the GOT power supply section by applying 100 or less which is used exclusively for the GOT Not doing so may cause an electric shock or malfunction Correctly wire the GOT power supply section after confirming the rated voltage and terminal arrangement of the product Not doing so can cause a fire or failure Exercise care to avoid foreign matter such as chips and wire offcuts entering the GOT Not doing so can cause a fire failure or malfunction WIRING PRECAUTIONS c AUTION e The cables connected to the unit must be run in ducts or clamped Not doing so can cause the un
7. cable connector for PLC communication 12 Cable connector for Connector for either 11 or 13 and for selection of PLC communication the PLC communication type Connected to RS 422 before shipping Opened and closed when the PLC communication type is changed RS 422 lt RS 232 before shipping RS 422 the option function board is mounted or the battery is replaced Used to hold the Handy GOT in hand by putting a hand under the strap Length adjustable Environmental protection back cover 13 RS 422 interface Connector for PLC communication using RS 422 14 Connector for option Connector for mounting the GT11 50FNB type option function board function board For the connection to the controller microcomputer board or PC refer to the following 5 Hand strap Model consumption current serial No Hardware 6 Rating plate Firmware version is indicated 7 Grip switch Switch for external direct wiring independent contact GT11 Handy GOT User s Manual 3 Specifications 3 1 General Specifications Item Specifications Operating ambient Display section 0 to 40 C temperature Other than Display section 0 to 40 C Storage ambient temperature 20 to 60 C Operating ambient humidity 10 to 90 RH non condensing The wet bulb temperature is 39 C or less Storage ambient humidity 10 to 90 RH non condensing The wet bulb temperature is 39 C or less Frequency Acceleratio
8. due to false output or malfunction If a communication fault including cable disconnection occurs during monitoring on the GOT communication between the GOT and PLC CPU is suspended and the GOT becomes inoperative A system where the GOT is used should be configured to perform any significant operation to the system by using the switches of a device other than the GOT on the assumption that a GOT communication fault will occur Not doing so can cause an accident due to false output or malfunction Do not use the GOT as the warning device that may cause a serious accident An independent and redundant hardware or mechanical interlock is required to configure the device that displays and outputs serious warning Failure to observe this instruction may result in an accident due to incorrect output or malfunction Incorrect operation of the touch switch s may lead to a serious accident if the GOT backlight is gone out When the GOT backlight goes out the POWER LED flickers green orange and the display section turns black and causes the monitor screen to appear blank while the input of the touch switch s remains active This may confuse an operator in thinking that the GOT is in screensaver mode who then tries to release the GOT from this mode by touching the display section which may cause a touch switch to operate Note that the following occurs on the GOT when the backlight goes out The POWER LED flickers green orange and
9. frequency Dielectric withstand voltage 500V AC for 1 minute across power supply terminals and earth Insulation resistance 10MQ or larger by insulation resistance tester across power supply terminals and earth The GOT continues to operate even upon 5ms or shorter instantaneous power failure The GOT stops operating if there is extended power failure or voltage drop while it automatically resumes operation as soon as the power is restored 3 4 External Dimensions 18 0 71 75 2 96 gt gt 72 2 84 Unit mm inch e How to confirm production year and month The production year and month of the battery built in the purchased GOT can be confirmed by the production No S N marked on the GOT main unit Example nameplate manufacture s serial number 1010001 5 Cautions on Using Emergency Stop Switch 1 When using the emergency stop switch in the handy GOT judge the validity to use the emergency stop switch in accordance with the risk assessment in your system 2 When using the parallel circuit which disables the emergency stop status while the handy GOT is removed the system may not conform to the safety standards Check the safety standards required in the system and then judge the validity to use the emergency stop switch GRAPHIC OPERATION TERMINAL MODEL GT1155HS QSBD IN 20 4 26 4VDC POWER 9 84W MAX SIN 4010001 KAN AS MITSUBISHI ELECTRIC CORPORATION Hardware versi
10. or slight personal injury or physical damage Depending on circumstances procedures indicated by CAUTION may also be linked to serious results In any case it is important to follow the directions for usage DESIGN PRECAUTIONS WARNING e Some failures of the GOT or cable may keep the outputs on or off An external monitoring circuit should be provided to check for output signals which may lead to a serious accident Not doing so can cause an accident due to false output or malfunction If a communication fault including cable disconnection occurs during monitoring on the GOT communication between the GOT and PLC CPU is suspended and the GOT becomes inoperative A system where the GOT is used should be configured to perform any significant operation to the system by using the switches of a device other than the GOT on the assumption that a GOT communication fault will occur Not doing so can cause an accident due to false output or malfunction Do not use the GOT as the warning device that may cause a serious accident An independent and redundant hardware or mechanical interlock is required to configure the device that displays and outputs serious warning Failure to observe this instruction may result in an accident due to incorrect output or malfunction Incorrect operation of the touch switch s may lead to a serious accident if the GOT backlight is gone out When the GOT backlight goes out the POWER LED flickers green or
11. resistance load Maximum rating 0 3A 24VDC induction load Life 100 000 times PLC communication Select either RS 422 or RS 232 when used PC communication Project data upload download OS installation transparent function Switch Emergency stop switch times 1 switch single wiring IDEC AS6Q 2KT1PB Keylock switch 2 position switch cannot be removed Two keys are provided 1 LED Lit in green Power is correctly supplied POWER LED Lit in orange Screen saving and backlight not lit LED Blinks in orange green Blown back light bulb Not lit Power is not supplied LED for operation switch display 6 LEDs green lighting control from the display section LED for grip switch display 1 LED green lighting control from display unit part Battery GT11 50BAT lithium battery Magnesium maganese dioxide lithium primary battery Backup target Clock data alarm history and recipe data Approx 5 years Operating ambient temperature of 25 C Guaranteed 1 year RS422 RS232 1ch Transmission speed 115 200 57 600 38 400 19 200 9 600 4 800bps Ser ee eee Connector shape Round 32 pins male Application RS232 1ch RS 232 Transmission speed 115 200 57 600 38 400 19 200 9 600 4 800bps Connector shape MINI DIN 6 pin Female Built in Application intents USB Full Speed 12Mbps 1ch USB Connector shape Mini B Application CF card Application Option function board 4 Environmental protective structure 5 External dimensions Weigh
12. settings of the object functions used in GT Designer2 Describes methods of the GT Designer3 installation operation basic operation for drawing and transmitting data to GOT1000 series Describes specifications and settings of the object functions used in GT Designer3 Manual Number Model Code SH 080529ENG 1D7M24 SH 080530ENG 1D7M25 SH 080866ENG 1D7MB9 SH 080867ENG sold separately 1 ome GT11 Handy GOT User s Manual Describes the Handy GOT hardware relevant content such as part names external JY997D20101 Hardware Utility Connection 1 2 2 2 dimensions mounting power supply wiring specifications and introduction to option JY997D20102 sold separately devices 09R817 The manual in PDF format is included in the GT Works2 GT Designer2 GT Works3 GT Designer3 products For details of a PLC to be connected refer to the PLC user s manual respectively Bundled Items Product ee Bundled item Quantity Specifications Name Operation switch name character sheets 1 OHP sheet 2 Reference dimension sheet switch name change sheet 1 One sheet 2 One sheet mount Selector switch keys 2 GT11 Handy GOT General Description This manual 1 1 Features 1 Improved monitoring performance and connectivity to FA devices Two types of display modes are provided 256 color display and monochrome display In the monochrome display 16 scales are used to improve the display High speed monitoring through hi
13. 100 8310 JAPAN
14. Dec Year example 2008 Last digit of year e Battery life Approximate battery life 5 years ambient temperature 25 C Battery replacement In 4 to 5 years Approximate life is 5 years but life may be shorter depending on the ambient temperature therefore note that the battery must be replaced in 4 to 5 years Make sure to purchase a new battery as needed as it self discharges Battery status can be confirmed on a GOT utility screen For details of battery status or how to output alarm refer to the following GT11 Handy GOT User s Manual 5 Cautions on Using Emergency Stop Switch 1 When using the emergency stop switch in the handy GOT judge the validity to use the emergency stop switch in accordance with the risk assessment in your system 2 When using the parallel circuit which disables the emergency stop status while the handy GOT is removed the system may not conform to the safety standards Check the safety standards required in the system and then judge the validity to use the emergency stop switch This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of M
15. JY997D22801K MITSUBISHI ELECTRIC GT1155HS QSBD GT1150HS QLBD GT11 Handy GOT General Description GRAPHIC OPERATION TERMINAL Manual Number JY997D22801K This manual describes the part names dimensions mounting and specifications of the product Before use read this manual and manuals of relevant products fully to acquire proficiency in handling and operating the product Make sure to learn all the product information safety information and precautions And store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user Registration The company name and the product name to be described in this manual are the registered trademarks or trademarks of each company Effective April 2015 Specifications are subject to change without notice 2008 MITSUBISHI ELECTRIC CORPORATION Safety Precaution Read these precautions before using Before using this product please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly The precautions given in this manual are concerned with this product In this manual the safety precautions are ranked as WARNING and CAUTION Indicates that incorrect handling may cause hazardous N WARNING conditions resulting in death or severe injury Indicates that incorrect handling may cause hazardous CAUTION conditions resulting in medium
16. Lit in orange For the PC connection refer to the following 6 7 Operation switch name sheet prepared by the user installation example Specifications Switch for external direct wiring independent contact Switch for external direct wiring independent contact Displays the utility screen and the user creation screen For touch switch operation on the utility screen and the user creation screen Place concave shape where the operation switch name sheet created by user is installed Transparent cover to fix the operation switch name sheet created by user removed when a sheet is inserted Display LED for grip switch green lighting control from display section For external connection cable connection for PLC switch and power supply external wiring connector round 32 pins male Switch for external direct wiring independent contact Display LED for operation switch green lighting control from display section Power is correctly supplied Screen saving and backlight not lit Blinks in orange green Blown back light bulb Not lit Power is not supplied GT11 Handy GOT User s Manual 2 2 Back Panel Environmental protection back cover closed 1 2 1 No 1 Specifications Hook for mounting a Hook for mounting a neck strap must be prepared by neck str
17. alarm refer to the following GT11 Handy GOT User s Manual This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi opportunity loss or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi Electric e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO
18. ange and the display section turns black and causes the monitor screen to appear blank while the input of the touch switch s remains active This may confuse an operator in thinking that the GOT is in screensaver mode who then tries to release the GOT from this mode by touching the display section which may cause a touch switch to operate Note that the following occurs on the GOT when the backlight goes out The POWER LED flickers green orange and the monitor screen appears blank DESIGN PRECAUTIONS NC AUTION Do not bundle the control and communication cables with main circuit power or other wiring Run the above cables separately from such wiring and keep them a minimum of 100mm 3 94in apart Not doing so noise can cause a malfunction Do not press the GOT display section with a pointed material as a pen or driver Doing so can result in a damage or failure of the display section Before connecting to GOT turn ON the controller to enable the communication When the communication of controller is not available a communication error may occur in GOT e Be sure to shut off all phases of the external power supply used by the system before mounting or removing the GOT to from the panel Not doing so can cause the unit to fail or malfunction Always turn off the power ON OFF switch on the connector conversion box before connecting or disconnecting the GOT to it Connecting or disconnecting the GOT with the power bein
19. angeable 1 0A Power consumption 9 84W 410mA 24V DC or less 9 36W 390mA 24V DC or less At backlight off 4 32W 180mA 24V DC or less Inrush current 15A or less 26 4V 2ms Item GT1150HS QLBD Input power supply voltage Permissible instantaneous power failure time 1 Within 5ms Noise immunity Noise voltage 1000Vp p Noise width 1us by noise simulator of 30 to 100Hz noise frequency Dielectric withstand voltage 500V AC for 1 minute across power supply terminals and earth Insulation resistance 10MQ or larger by insulation resistance tester across power supply terminals and earth The GOT continues to operate even upon 5ms or shorter instantaneous power failure The GOT stops operating if there is extended power failure or voltage drop while it automatically resumes operation as soon as the power is restored 3 4 External Dimensions 18 0 71 75 2 96 gt t gt 72 2 84 Unit mm inch 4 Maintenance and Inspection The GOT does not include consumable components that will cause the shorten life However note that battery life is 5 years and LCD life is 50 000 hours The life of backlight in GT1155HS QSBD is 75 000 hours and that in GT1150HS QLBD is 54 000 hours It is recommended to replace the battery periodically For the replacement of the liquid crystal screen and backlight please consult your nearest sales office or FA Center 4 1 Daily Inspection Daily inspection it
20. ap the user Hook for hanging on walls 2 Hook when the Handy GOT is used hanging on walls Environmental protection back cover screw For opening and closing the environmental protection back cover drop prevention screw Opened and closed when the PLC communication type is changed RS 422 lt RS 232 before shipping RS 422 the option function board is mounted or the battery is replaced Used to hold the Handy GOT in hand by putting a hand under the strap Length adjustable Environmental 4 protection back cover 5 Hand strap Model consumption current serial No Hardware 6 Rating plate Firmware version is indicated 7 Grip switch Switch for external direct wiring independent contact 3 Specifications 3 1 General Specifications Item Operating ambient Display section 0 to 40 C temperature Other than Display section 0 to 40 C Storage ambient temperature 20 to 60 C Operating ambient humidity Storage ambient humidity Conforms to JIS B3502 and vibration Vibration resistance 1IEC61131 2 vibration Shock resistance Operating atmosphere Operating altitude 2000 m 6562 ft max Overvoltage category 2 II or less Pollution degree s 2 or less Cooling method Self cooling Environmental protection back cover opened 14 Option function board installed No Specifications 8 Battery holder GT11 50BAT type battery holder GT11 50BAT type b
21. ar To prevent heat damage the screen saver function is effective For details on the screen saver function refer to the following GT11 Handy GOT User s Manual 2 Using the GOT Backlight OFF function can prolong the life of the backlight For details on the Backlight OFF function refer to the following GT11 Handy GOT User s Manual 3 ROM in which new data can be written without deleting the written data 4 Necessity of mounting the option function board may differ depending on the hardware version Refer to the following for details GT11 Handy GOT User s Manual 5 Note that this does not guarantee all user s operation environment The protection is not applied when the interface environment protection cover or environment protection back cover is removed In addition the product may not be used in environments under exposition of oil or chemicals for a long period of time or in environments filled with oil mist 3 3 Power Supply Specifications Specifications 24V DC 10 15 ripple voltage 200mV or less Fuse built in not exchangeable 1 0A Power consumption 9 84W 410mA 24V DC or less 9 36W 390mA 24V DC or less At backlight off 4 32W 180mA 24V DC or less Inrush current 15A or less 26 4V 2ms Item GT1150HS QLBD Input power supply voltage Permissible instantaneous power failure time Within 5ms Noise immunity Noise voltage 1000Vp p Noise width 1us by noise simulator of 30 to 100Hz noise
22. attery For storing clock data 4 Battery alarm history and recipe data Connector for battery connection 11 RS 232 interface 10 For GT11 50BAT type battery connection Connector for PLC communication using RS 232 Interface cable connector for PLC communication 12 Cable connector for Connector for either 11 or 13 and for selection of PLC communication the PLC communication type Connected to RS 422 before shipping 13 RS 422 interface Connector for PLC communication using RS 422 14 Connector for option Connector for mounting the GT11 50FNB type option function board function board For the connection to the controller microcomputer board or PC refer to the following GT11 Handy GOT User s Manual Specifications 10 to 90 RH non condensing The wet bulb temperature is 39 C or less 10 to 90 RH non condensing The wet bulb temperature is 39 C or less Frequency Acceleration Half amplitude Sweep Count Under intermittent St9H2 3sm 9 to 150Hz 9 8m s2 10 times each in X Conforms to JIS B3502 IEC 61131 2 147 m s2 3 times each in X Y and Z directions Must be free of lamp black corrosive gas flammable gas or excessive amount of electro conductive dust particles and must be no direct sunlight Same as for saving 1 Do not use or store the GOT under pressure higher than the atmospheric pressure of altitude Om Oft Failure to observe thi
23. d recipe data Screen data is stored in the flash memory and data is retained even if the battery is dead e Battery model name Handy GOT is shipped with the following battery Product name Model name GT11 50BAT e Battery replacement procedure 1 Turn the GOT power off 2 Loosen the environmental protection back cover screws at four points on GOT rear face to remove the cover Environmental sacra ot protection ack cover back cover screw screw 3 Remove the old battery from the holder 4 Disconnect the old battery connector and insert the new battery connector within 30s 5 Insert the battery into the holder Battery Battery holder Connector for battery connection 6 Attach the environmental protection back cover and tighten the screws Tightening torque 36 to 48 Ne cm 7 Turn the GOT power on 8 Check if the battery condition is normal with the utility Refer to the following for the details of battery status display GT11 Handy GOT User s Manual protection back cover screw back cover screw Specifications Item GT1155HS QSBD GT Designer2 Version2 15R or later GT Designer3 Version1 01B or later GT1150HS QLBD Compatible software package 1 Bright dots always lit and dark dots unlit may appear on a liquid crystal display panel It is impossible to completely avoid this symptom as the liquid crystal display comprises of a great number of display elements Flickers ma
24. e GT Designer3 installation operation basic operation for drawing and transmitting data to GOT1000 series Describes specifications and settings of the object functions used in GT Designer3 STARTUP MAINTENANCE PRECAUTIONS CAUTION e Do not disassemble or modify the unit Doing so can cause a failure malfunction injury or fire e Do not touch the conductive and electronic parts of the unit directly Doing so can cause a unit malfunction or failure e The cables connected to the unit must be run in ducts or clamped Not doing so can cause the unit or cable to be damaged due to the dangling motion or accidental pulling of the cables or can cause a malfunction due to a cable connection fault When unplugging the cable connected to the unit do not hold and pull the cable portion Doing so can cause the unit or cable to be damaged or can cause a malfunction due to a cable connection fault Replace battery with GT11 50BAT by Mitsubishi electric Co only Use of another battery may present a risk of fire or explosion Dispose of used battery promptly Keep away from children Do not disassemble and do not dispose of in fire DISPOSAL PRECAUTIONS CAUTION e When disposing of the product handle it as industrial waste e When disposing of batteries separate them from other wastes according to the local regulations For details of the battery directive in EU member states refer GOT User s Manual TRANSPORTATION PRECAUTIONS
25. e sequence programs using the personal computer connected to GOT is available during direct connection to A QnA L Q or FX series PLC CPU FA Transparent function 2 Part Name 2 1 Front Panel een eee Cer re E F1 F2 F3 F4 F5 F6 ALO ot 11 10 9 8 a1 6 7 Operation switch name sheet prepared by the user installation example 12 7 g No Specifications 1 Keylock switch 2 position SW Switch for external direct wiring independent contact 2 Emergency stop switch Switch for external direct wiring independent contact 3 Logo 2 places Removable 4 Display section Displays the utility screen and the user creation screen 5 Touch panel For touch switch operation on the utility screen and the user creation screen 6 Operation switch name sheet installation place Place concave shape where the operation switch name sheet created by user is installed 7 Operation switch name sheet cover Transparent cover to fix the operation switch name sheet created by user removed when a sheet is inserted 8 Display LED for grip switch Display LED for grip switch green lighting control from display section For external connection cable connection for PLC switch and power supply external wiring 9 External interface connector connector round 32 pins male 10 Operation switch 6 switches S
26. ed torque range Undertightening can cause a short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit TEST OPERATION PRECAUTIONS WARNING e Before performing the test operations of the user creation monitor screen such as turning ON or OFF bit device changing the word device current value changing the settings or current values of the timer or counter and changing the buffer memory current value read through the manual carefully and make yourself familiar with the operation method During test operation never change the data of the devices which are used to perform significant operation for the system False output or malfunction can cause an accident STARTUP MAINTENANCE PRECAUTIONS WARNING e When power is on do not touch the terminals Doing so can cause an electric shock or malfunction e Connect the battery correctly Do not discharge disassemble heat short solder or throw the battery into the fire Incorrect handling may cause the battery to generate heat burst or take fire resulting in injuries or fires e Before starting cleaning or terminal screw retightening always switch off the power externally in all phases Not switching the power off in all phases can cause a unit failure or malfunction Undertightening can cause a short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the scr
27. ee to which conductive material is generated in the environment where the equipment is used In pollution degree 2 only non conductive pollution occurs but temporary conductivity may be produced due to condensation 3 2 Performance Specifications Specifications GT1155HS QSBD Item GT1150HS QLBD STN color liquid crystal STN monochrome white black liquid crystal Display size W115 4 53 x H86 3 39 mm inch Display Display character 16 dot standard font 20 characters x 15 lines 12 dot standard font 26 characters x 20 lines section Display color 256 colors Monochrome white black 16 scales Contrast adjustment 16 level adjustment Intensity of LCD only 380 cd m2 Adjustable in 8 levels 220 cd m2 Adjustable in 8 levels Intensity adjustment 8 level adjustment Approx 50 000h Time for display intensity to become 1 5 at operating ambient temperature of 25 C Cold cathode fluorescent tube irreplaceable by a user backlight shutoff detection function is included Backlight ae Backlight off screen saving time can be set Life 2 Approx 75 000h or longer Time for display intensity reaches Approx 54 000h or longer Time for display intensity 50 at the operating ambient temperature of 25 C reaches 50 at the operating ambient temperature of 25 C Number of touch keys 300 keys screen Matrix structure of 15 lines x 20 columns Touch panel Number of points touched Maximum of 2 points simultaneously 1 million times or more o
28. ems Inspection eae Inspection Item Method Action Loose terminal Retghien Retighten screws with Not loose screwdriver Proximate Proper solderless terminals vispal ongck Poon Retighten Visual check Not loose connector fixing screws Dirt on protection gt Not Replace with Vistaleneck outstanding new one Foreign material No foreign attachment Miavalcheck matter sticking REMOVE ora Refer to the following for the model names of the protection sheet or the replacement procedure screws terminal screws o 5 g D c 2 5 O D f f e O Loose connectors Usage status GT11 Handy GOT User s Manual 4 2 Periodic Inspection Yearly or half yearly inspection items The following inspection should also be performed when equipment has been moved or modified or the wiring changed Inspection E No Inspection Item Method Ambient Make Ot 5 o 40 C i measurement oes in control ith Surrounding Ambient iid n temperature i environment humidity Aa Ge ii inside control e e m panel is ambient o corrosive Atmosphere corrosive gas temperature 24V DC Measure 20 4 to 26 4V Change supply voltage across DC power terminals Should be Looseness Move module mounted firmly 3 No dirt Dirt foreign foreign matter Misvalcneck matter sticking Retighten screws with Not loose sa i terminal screwdriver Proper solderless Visual check Loose connectors Visual check Not lo
29. eration switch display 6 LEDs green lighting control from the display section LED for grip switch display 1 LED green lighting control from display unit part Battery GT11 50BAT lithium battery Magnesium maganese dioxide lithium primary battery Backup target Clock data alarm history and recipe data Approx 5 years Operating ambient temperature of 25 C Guaranteed 1 year RS422 RS232 1ch Transmission speed 115 200 57 600 38 400 19 200 9 600 4 800bps or eer gee Connector shape Round 32 pins male Application PLC communication Select either RS 422 or RS 232 when used RS232 1ch RS 232 Transmission speed 115 200 57 600 38 400 19 200 9 600 4 800bps Connector shape MINI DIN 6 pin Female Built in Application PC communication Project data upload download OS installation transparent function InteHace USB Full Speed 12Mbps 1ch USB Connector shape Mini B Application PC communication Project data upload download OS installation transparent function Conforming to PCMCIA compact flash slot 1ch Connector shape Dedicated for TYPE I Application Data transfer data storage CF card Option function board 4 For mounting the option function board 1ch Equivalent to IP65F excluded on the relay connector side of external cable valid when the external cable is connected W176 6 93 x H220 8 67 x D93 3 67 mm inch 1 0kg Handy GOT main unit only Environmental protective structure 5 External dimensions Weight
30. ews or unit Associated Manuals STARTUP MAINTENANCE PRECAUTIONS CAUTION e Do not disassemble or modify the unit Doing so can cause a failure malfunction injury or fire e Do not touch the conductive and electronic parts of the unit directly Doing so can cause a unit malfunction or failure e The cables connected to the unit must be run in ducts or clamped Not doing so can cause the unit or cable to be damaged due to the dangling motion or accidental pulling of the cables or can cause a malfunction due to a cable connection fault When unplugging the cable connected to the unit do not hold and pull the cable portion Doing so can cause the unit or cable to be damaged or can cause a malfunction due to a cable connection fault Replace battery with GT11 50BAT by Mitsubishi electric Co only Use of another battery may present a risk of fire or explosion Dispose of used battery promptly Keep away from children Do not disassemble and do not dispose of in fire DISPOSAL PRECAUTIONS CAUTION e When disposing of the product handle it as industrial waste e When disposing of batteries separate them from other wastes according to the local regulations For details of the battery directive in EU member states refer GOT User s Manual TRANSPORTATION PRECAUTIONS CAUTION e When transporting lithium batteries make sure to treat them based on the transport regulations Refer to User s Manual for details of the reg
31. g turned on may result in damage to the unit or malfunctions Be sure to shut off all phases of the external power supply used by the system before mounting or removing the relay cable onto from the GOT Be sure to shut off all phases of the external power supply used by the system before mounting or removing the option function board on to from the GOT Not doing so can cause the unit to fail or malfunction When installing the option function board or battery or operating the reset switch wear an earth band etc to avoid the static electricity The static electricity can cause the unit to fail or malfunction e Use the GOT in the environment that satisfies the general specifications described in this manual Not doing so can cause an electric shock fire malfunction or product damage or deterioration Never drop cutting chips and electric wire chips into the ventilation window of the Handy GOT when you drill screw holes or perform wiring Otherwise fire failure or malfunction may be caused Connect connection cables securely to the specified connectors while the power is turned OFF Imperfect connection may cause malfunction or failure When connecting cables pay attention to the contents described in this section Especially attach the rear cover so that PCBs inside the Handy GOT are not interfered with connection cables Securely connect the option function board to the connector provided for the board When inserting removing
32. gh speed communication at maximum of 115 2kbps Multiple languages are displayed using the Unicode2 1 compatible fonts and beautiful characters are drawn using the TrueType and high quality fonts High speed display and high speed touch switch response 2 More efficient GOT operations including screen design startup adjustment management and maintenance works The display screen of the display unit is created using a drawing software for PC GT Designer2 Ver2 18U or later GT Designer3 Ver1 01B or later The 3MB user memory is included as standard CF card interface is included as standard The USB connector interface is included as standard 3 Enhanced support of FA device setup tools Transferring or monitoring the sequence programs using the personal computer connected to GOT is available during direct connection to A QnA L Q or FX series PLC CPU FA Transparent function 2 Part Name 2 1 Front Panel 12 11 10 9 8 No 1 Keylock switch 2 position SW 2 Emergency stop switch 3 Logo 2 places Removable 4 Display section 5 Touch panel 6 Operation switch name sheet installation place 7 Operation switch name sheet cover 8 Display LED for grip switch 9 External interface connector 10 Operation switch 6 switches 11 Display LED for operation switch 6 LEDs Lit in green 12 POWER LED
33. ing the reset switch wear an earth band etc to avoid the static electricity The static electricity can cause the unit to fail or malfunction e Use the GOT in the environment that satisfies the general specifications described in this manual Not doing so can cause an electric shock fire malfunction or product damage or deterioration Never drop cutting chips and electric wire chips into the ventilation window of the Handy GOT when you drill screw holes or perform wiring Otherwise fire failure or malfunction may be caused Connect connection cables securely to the specified connectors while the power is turned OFF Imperfect connection may cause malfunction or failure When connecting cables pay attention to the contents described in this section Especially attach the rear cover so that PCBs inside the Handy GOT are not interfered with connection cables Securely connect the option function board to the connector provided for the board When inserting removing a CF card into from the GOT turn the CF card access switch off in advance Failure to do so may corrupt data within the CF card When inserting a CF card into the GOT push it into the insertion slot until the CF card eject button will pop out Failure to do so may cause a malfunction due to poor contact When removing a CF card from the GOT make sure to support the CF card by hand as it may pop out Failure to do so may cause the CF card to drop from the GOT and break
34. it or cable to be damaged due to the dangling motion or accidental pulling of the cables or can cause a malfunction due to a cable connection fault When unplugging the cable connected to the unit do not hold and pull the cable portion Doing so can cause the unit or cable to be damaged or can cause a malfunction due to a cable connection fault Plug the communication cable into the connector of the connected unit and tighten the mounting and terminal screws in the specified torque range Undertightening can cause a short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit TEST OPERATION PRECAUTIONS WARNING e Before performing the test operations of the user creation monitor screen such as turning ON or OFF bit device changing the word device current value changing the settings or current values of the timer or counter and changing the buffer memory current value read through the manual carefully and make yourself familiar with the operation method During test operation never change the data of the devices which are used to perform significant operation for the system False output or malfunction can cause an accident STARTUP MAINTENANCE PRECAUTIONS WARNING e When power is on do not touch the terminals Doing so can cause an electric shock or malfunction e Connect the battery correctly Do not discharge disassemble heat short solder or
35. itsubishi opportunity loss or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi Electric e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN JY997D22801K MITSUBISHI ELECTRIC GT1155HS QSBD GT1150HS QLBD GT11 Handy GOT General Description GRAPHIC OPERATION TERMINAL Manual Number JY997D22801K This manual describes the part names dimensions mounting and specifications of the product Before use read this manual and manuals of relevant products fully to acquire proficiency in handling and operating the product Make sure to learn all the product information safety information and preca
36. n Half amplitude Sweep Count Under intermittent Sto9Hz 35mm etal 9to150Hz 8 8mist _ 10 times each in x Y and Z directions Under continuous Saa J Memm a wem p a a Conforms to JIS B3502 IEC 61131 2 147 m s2 3 times each in X Y and Z directions Conforms to JIS Vibration resistance B3502 and IEC61131 2 Shock resistance Must be free of lamp black corrosive gas flammable gas or excessive amount of electro conductive dust particles and Operating amosphere must be no direct sunlight Same as for saving Operating altitude 2000 m 6562 ft max Overvoltage category 2 II or less Pollution degree 3 2 or less Cooling method Self cooling 1 Do not use or store the GOT under pressure higher than the atmospheric pressure of altitude Om Oft Failure to observe this instruction may cause a malfunction When the air inside the control panel is purged by pressurization the surface sheet may be lifted by high pressure As a result the touch panel may be difficult to press and the sheet may be peeled off 2 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the machinery within the premises Category II applies to equipment for which electrical power is supplied from fixed facilities The surge voltage withstand level for up to the raged voltage of 300 V is 2500 V 3 This index indicates the degr
37. ndard font 20 characters x 15 lines 12 dot standard font 26 characters x 20 lines 16 level adjustment Zajeamayagustabe 8 eves 8 level adjustment Approx 50 000h Time for display intensity to become 1 5 at operating ambient temperature of 25 C Backlight Backlight off screen saving time can be set 300 keys screen Matrix structure of 15 lines x 20 columns Minimum 16 x 16 dots per key Touch panel Maximum of 2 points 1 million times or more operating force 0 98N max Flash memory Internal for storing project data 3Mbytes and OS memar a of write times TOU OOO MINES D drive Internal clock Accuracy Buzzer output Single tone tone length adjustable Operation switch Grip switch times SRAM Internal 512kbyes battery backup 45 seconds 45 seconds per month 6 switches 6 contacts common N O contact Maximum rating 10mA 24VDC Life 1 000 000 times 1 switch single wiring IDEC HE3B M2PB Enable switch deadman switch 3 position system of OFF lt gt ON lt gt OFF 2 N O contacts Maximum rating 1A 24VDC resistance load Maximum rating 0 3A 24VDC induction load Life 100 000 1 switch single wiring OMRON A165E S 02 2 N C contacts Maximum rating 1A 24VDC resistance load Maximum rating 0 3A 24VDC induction load Life 100 000 2 notch type Manual stop at each position A key can be inserted and removed on only the left side On the right side a key 2 position Maximum rating 1A 24VDC
38. nvironmental temperature Especially in the low temperature environment the display response becomes slow due to the characteristics of the STN liquid crystal Please check the display response in advance for using this product When the same screen is displayed for a long time an incidental color or partial discoloration is generated on the screen due to heat damage and it may not disappear To prevent heat damage the screen saver function is effective For details on the screen saver function refer to the following GT11 Handy GOT User s Manual 2 Using the GOT Backlight OFF function can prolong the life of the backlight For details on the Backlight OFF function refer to the following GT11 Handy GOT User s Manual 3 ROM in which new data can be written without deleting the written data 4 Necessity of mounting the option function board may differ depending on the hardware version Refer to the following for details GT11 Handy GOT User s Manual 5 Note that this does not guarantee all user s operation environment The protection is not applied when the interface environment protection cover or environment protection back cover is removed In addition the product may not be used in environments under exposition of oil or chemicals for a long period of time or in environments filled with oil mist 3 3 Power Supply Specifications Specifications 24V DC 10 15 ripple voltage 200mV or less Fuse built in not exch
39. on MADE IN JAPAN Actual product nameplate differs from the example shown above 7 digit lt Dec 2009 or before gt 1 0 4 0 fo loh ponnn L Control number Month example Jan L Control number 1 to 9 Jan to Sep Month example Oct X Oct Y Nov Z Dec lt Jan 2010 or later gt 1 to 9 Jan to Sep X Oct Y Nov Z Dec Year example 2009 Last digit of year Year example 2010 Last two digit of year The production date of the optional replacement battery can be confirmed by the lot No marked on the nameplate label affixed on the battery Nameplate Connector Model name T11 50BAT LOT LOT 101 lt Jan 2010 or later gt lt Dec 2009 or before gt 3 digit 2 digit Ho x T Month T Month example Jan example Oct 1 Jan to 9 Sep 1 Jan to 9 Sep X Oct Y Nov Z Dec X Oct Y Nov Z Dec Year example 2010 Year example 2008 Last two digit of year Last digit of year e Battery life Approximate battery life 5 years ambient temperature 25 C Battery replacement In 4 to 5 years Approximate life is 5 years but life may be shorter depending on the ambient temperature therefore note that the battery must be replaced in 4 to 5 years Make sure to purchase a new battery as needed as it self discharges Battery status can be confirmed on a GOT utility screen For details of battery status or how to output
40. ose Check the system alarm Action 2 Power supply voltage check Retighten screws Remove clean 4 Connection Proximate stat s Correct Retighten connector fixing screws Replace with new battery when the current battery 5 Se on Preventive has reached the the Alarm maintenance specified life span Information even if battery Screen voltage is not displayed 4 3 Battery Replacement The battery backs up clock data alarm history and recipe data Screen data is stored in the flash memory and data is retained even if the battery is dead e Battery model name Handy GOT is shipped with the following battery Product name Model name GT11 50BAT e Battery replacement procedure 1 Turn the GOT power off 2 Loosen the environmental protection back cover screws at four points on GOT rear face to remove the cover Environmental Ng dean protection ack cover back cover screw screw 3 Remove the old battery from the holder 4 Disconnect the old battery connector and insert the new battery connector within 30s 5 Insert the battery into the holder Battery Battery holder Connector for battery connection 6 Attach the environmental protection back cover and tighten the screws Tightening torque 36 to 48 Ne cm 7 Turn the GOT power on 8 Check if the battery condition is normal with the utility Refer to the following for the details of battery status display
41. perating force 0 98N max Flash memory Internal for storing project data 3Mbytes and OS Life Memely Number of write times TOG OOO MINES D drive SRAM Internal 512kbyes battery backup 45 seconds 45 seconds per month Internal clock Accuracy Single tone tone length adjustable 6 switches 6 contacts common N O contact Maximum rating 10mA 24VDC Life 1 000 000 times Buzzer output Operation switch 1 switch single wiring IDEC HE3B M2PB Enable switch deadman switch 3 position system of OFF lt gt ON lt gt OFF 2 N O contacts Maximum rating 1A 24VDC resistance load Maximum rating 0 3A 24VDC induction load Life 100 000 times 1 switch single wiring OMRON A165E S 02 Grip switch Switch Emergency stop switch 2 N C contacts Maximum rating 1A 24VDC resistance load Maximum rating 0 3A 24VDC induction load Life 100 000 times 1 switch single wiring IDEC AS6Q 2KT1PB Keylock switch 2 notch type Manual stop at each position A key can be inserted and removed on only the left side On the right side a key 2 position switch cannot be removed Two keys are provided 2 position Maximum rating 1A 24VDC resistance load Maximum rating 0 3A 24VDC induction load Life 100 000 times 1 LED Lit in green Power is correctly supplied POWER LED Lit in orange Screen saving and backlight not lit LED Blinks in orange green Blown back light bulb Not lit Power is not supplied LED for op
42. s instruction may cause a malfunction When the air inside the control panel is purged by pressurization the surface sheet may be lifted by high pressure As a result the touch panel may be difficult to press and the sheet may be peeled off 2 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the machinery within the premises Category II applies to equipment for which electrical power is supplied from fixed facilities The surge voltage withstand level for up to the raged voltage of 300 V is 2500 V 3 This index indicates the degree to which conductive material is generated in the environment where the equipment is used In pollution degree 2 only non conductive pollution occurs but temporary conductivity may be produced due to condensation 3 2 Performance Specifications Item GT1155HS QSBD STN color liquid crystal STN monochrome white black liquid crystal Specifications GT1150HS QLBD 256 colors Monochrome white black 16 scales Cold cathode fluorescent tube irreplaceable by a user backlight shutoff detection function is included Life 2 Approx 75 000h or longer Time for display intensity reaches Approx 54 000h or longer Time for display intensity 50 at the operating ambient temperature of 25 C reaches 50 at the operating ambient temperature of 25 C W115 4 53 x H86 3 39 mm inch Display 16 dot sta
43. t 1 0kg Handy GOT main unit only 4 Maintenance and Inspection The GOT does not include consumable components that will cause the shorten life However note that battery life is 5 years and LCD life is 50 000 hours The life of backlight in GT1155HS QSBD is 75 000 hours and that in GT1150HS QLBD is 54 000 hours It is recommended to replace the battery periodically For the replacement of the liquid crystal screen and backlight please consult your nearest sales office or FA Center 4 1 Daily Inspection Daily inspection items Inspection ye i Inspection Item Method Action Loose terminal Pana Retighten screws with Not loose screwdriver Proximate Proper solderless terminals visual emedk Conect Retighten Visual check Not loose connector fixing screws Dirt on protection Not Replace with yiatalpheck outstanding new one Foreign material No foreign attachment Misvalcneck matter sticking omevercieay Refer to the following for the model names of the protection sheet or the replacement procedure screws terminal screws a 5 s 7 c 2 5 O cb fa fa je O Loose connectors Usage status GT11 Handy GOT User s Manual 4 2 Periodic Inspection Yearly or half yearly inspection items The following inspection should also be performed when equipment has been moved or modified or the wiring changed No Inspection Item cere ea Ambient Make Ot o 40 C measurement ade i in con
44. the monitor screen appears blank DESIGN PRECAUTIONS NC AUTION Do not bundle the control and communication cables with main circuit power or other wiring Run the above cables separately from such wiring and keep them a minimum of 100mm 3 94in apart Not doing so noise can cause a malfunction Do not press the GOT display section with a pointed material as a pen or driver Doing so can result in a damage or failure of the display section Before connecting to GOT turn ON the controller to enable the communication When the communication of controller is not available a communication error may occur in GOT e Be sure to shut off all phases of the external power supply used by the system before mounting or removing the GOT to from the panel Not doing so can cause the unit to fail or malfunction Always turn off the power ON OFF switch on the connector conversion box before connecting or disconnecting the GOT to it Connecting or disconnecting the GOT with the power being turned on may result in damage to the unit or malfunctions Be sure to shut off all phases of the external power supply used by the system before mounting or removing the relay cable onto from the GOT Be sure to shut off all phases of the external power supply used by the system before mounting or removing the option function board on to from the GOT Not doing so can cause the unit to fail or malfunction When installing the option function board or battery or operat
45. throw the battery into the fire Incorrect handling may cause the battery to generate heat burst or take fire resulting in injuries or fires e Before starting cleaning or terminal screw retightening always switch off the power externally in all phases Not switching the power off in all phases can cause a unit failure or malfunction Undertightening can cause a short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit Associated Manuals The following manuals are relevant to this product When these loose manuals are required please consult with our local distributor Contents Manual Number Model Code Manual name GT Designer2 Version2 Basic Operation Data Transfer Manual For GOT1000 Series sold separately 1 GT Designer2 Version2 Screen Design Manual For GOT1000 Series 1 3 2 3 3 3 sold separately 1 GT Designer3 Version1 Screen Design Manual For GOT1000 Series Fundamentals 1 2 2 2 sold separately 1 GT Designer3 Version1 Screen Design Manual For GOT1000 Series Functions 1 2 2 2 sold separately 1 GT11 Handy GOT User s Manual Hardware Utility Connection 1 2 2 2 sold separately devices Describes methods of the GT Designer2 installation operation basic operation for drawing and transmitting data to GOT1000 series Describes specifications and settings of the object functions used in GT Designer2 Describes methods of th
46. trol 7 ith Surrounding Ambient ne temperature environment humidity pea hala 10 to 304RkI inside control ca F panel is ambient o corrosive Atmosphere corrosive gas temperature 24V DC 2 Power supply voltage Measure 20 4 to 26 4V Change supply check voltage across DC power terminals Should be Looseness Move module mounted firmly 3 No dirt Dirt foreign foreign matter Visual check matter sticking Retighten r screws with Not loose pis ea terminal screwdriver f Proper solderless Visual check Loose connectors Visual check Not loose Check the system alarm error code 5 500 report on the Alarm Information screen Action Retighten screws Remove clean 4 Connection Proximate status Correct Retighten connector fixing screws Replace with new battery when the current battery has reached the Preventive maintenance specified life span even if battery voltage is not displayed PC communication Project data upload download OS installation transparent function Conforming to PCMCIA compact flash slot 1ch Connector shape Dedicated for TYPE I Data transfer data storage For mounting the option function board 1ch Equivalent to IP65F excluded on the relay connector side of external cable valid when the external cable is connected W176 6 93 x H220 8 67 x D93 3 67 mm inch 4 3 Battery Replacement The battery backs up clock data alarm history an
47. urated models Before transporting the GOT turn the GOT power on and check that the battery voltage status is normal on the Time setting amp display screen utilities screen In addition confirm that the adequate battery life remains on the rating plate Transporting the GOT with the low battery voltage or the battery the reached battery life may unstabilize the backup data unstable during transportation Make sure to transport the GOT main unit and or relevant unit s in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of this manual as they are precision devices Failure to do so may cause the unit to fail Check if the unit operates correctly after transportation The following manuals are relevant to this product When these loose manuals are required please consult with our local distributor Manual name GT Designer2 Version2 Basic Operation Data Transfer Manual For GOT1000 Series sold separately 1 GT Designer2 Version2 Screen Design Manual For GOT1000 Series 1 3 2 3 3 3 sold separately 1 GT Designer3 Version1 Screen Design Manual For GOT1000 Series Fundamentals 1 2 2 2 sold separately 1 GT Designer3 Version1 Screen Design Manual For GOT1000 Series Functions 1 2 2 2 Describes methods of the GT Designer2 installation operation basic operation for drawing and transmitting data to GOT1000 series Describes specifications and
48. utions And store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user Registration The company name and the product name to be described in this manual are the registered trademarks or trademarks of each company Effective April 2015 Specifications are subject to change without notice 2008 MITSUBISHI ELECTRIC CORPORATION Safety Precaution Read these precautions before using Before using this product please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly The precautions given in this manual are concerned with this product In this manual the safety precautions are ranked as WARNING and CAUTION Indicates that incorrect handling may cause hazardous N WARNING conditions resulting in death or severe injury Indicates that incorrect handling may cause hazardous CAUTION conditions resulting in medium or slight personal injury or physical damage Depending on circumstances procedures indicated by CAUTION may also be linked to serious results In any case it is important to follow the directions for usage DESIGN PRECAUTIONS WARNING e Some failures of the GOT or cable may keep the outputs on or off An external monitoring circuit should be provided to check for output signals which may lead to a serious accident Not doing so can cause an accident
49. witch for external direct wiring independent contact 11 Display LED for operation switch 6 LEDs Display LED for operation switch green lighting control from display section Lit in green Power is correctly supplied Lit in orange Screen saving and backlight not lit Blinks in orange green Blown back light bulb Not lit Power is not supplied 12 POWER LED For the PC connection refer to the following GT11 Handy GOT User s Manual 2 2 Back Panel Environmental protection back cover closed Environmental protection back cover opened Pe 0 YO LT ler e I 3 3 ONY me r O 7 gt 14 Option function board installed O HQS Specifications Specifications op ne Hook for mounting a Hook for mounting a neck strap must be prepared by 8 Battery holder GT11 50BAT type battery holder nee meee 9 Batte GT11 50BAT type battery For storing clock data y alarm history and recipe data 10 a r For GT11 50BAT type battery connection Hook for hanging on walls Hook when the Handy GOT is used hanging on walls N Environmental protection back cover screw For opening and closing the environmental protection back cover drop prevention screw 11 RS 232 interface Connector for PLC communication using RS 232 Interface
50. y be observed depending on the display color Please note that these dots appear due to its characteristic and are not caused by product defect e Flickers and partial discoloration may be generated on the liquid crystal display panel due to the display contents or the contrast adjustment However please note that these phenomena appear due to its characteristic and are not caused by product defect e There is a difference in the display brightness and the color tones between liquid crystal display panels When using multiple liquid crystal display panels please note that there is an individual difference between them e A crosstalk shadow as an extension of the display may appear on the liquid crystal display panel Please note that it appears due to its characteristic e When the display section is seen from the outside of the display angle the display color seems like it has changed Please note that it is due to its characteristic Please note that the response time brightness and color of the liquid crystal display panel may vary depending on the usage environmental temperature Especially in the low temperature environment the display response becomes slow due to the characteristics of the STN liquid crystal Please check the display response in advance for using this product When the same screen is displayed for a long time an incidental color or partial discoloration is generated on the screen due to heat damage and it may not disappe