Fält EC II GSM Manual and installation instructions
Contents
1. 5 2 Product description The F lt EC II GSM is alarm equipment for the GSM network with built in duplex speech communication designed for installation in lifts lt complies with requirements according to EN81 1 2 and EN81 28 The product is CE marked The system consists of two separate units one central unit which is mounted on the rooftop of the lift and one speech unit that is mounted inside the lift car The units are connected to gether with a modular cable In the lift car either the existing or a separate alarm button is connected to the central unit When someone inside the lift pushes the alarm button the F lt EC II GSM automatically calls an alarm centre or a predefined alarm receiver and indicates where the alarm comes from At the same time voice communications is established and the person in distress can speak di rectly to staff at the alarm centre from where help will be dispatched F lt EC II GSM is normally programmed via a keypad on the rear side of the speech unit but can also be remote programmed Contact your local distributor or Falt Communications AB for more information Manual F lt EC II GSM Eng Art Nr 2135 Page 10 of 35 5 2 1 Overview of F lt EC II GSM functionality The central unit of the F lt EC II GSM is not visible to the passengers of the lift It is mounted on the roof of the lift car Its function is to initiate transmit and monitor alarm calls from the speech unit in the lift to the ala
2. 2 ecce P O 8 CO fx lt 1 9 gt P Time between test alarms Unit in DX days Acao P fe EA O O ao lt Phone No gt P Phone number to test alarm receiver Max 20 digits EET 20 EEECEP x Manual F lt EC II GSM Eng Art Nr 2135 Page 33 of 35 dl x o x O co 00 o an No Programming sequence Function P ao Ep o ce lt Code gt P Alarm code to test alarm receiver Max 10 digits P gt CA EX EN O ao lt Phone No gt a Phone number to battery alarm re ceivers Max 20 a z P gt gt gt 3 1 gt O a Test of Test of battery alarm receiver alarm receiver 2 ECECTCE 25 P o Ep D ER ao lt Code gt P Alarm code to battery alarm receiver Max 10 digits 26 P o 3 2 O P Activation of simple phone acknowl edge one na P gt EJ 37 2 17 P gt Disconnection of Disconnection of acknowledge P Go 3 2 EM P Reset of normal acknowledge se quence EECCCE lt Fwonte gt E possis PEE 1 Lo 3 lt Old PIN code gt Change of PIN code to SIM card lt New PIN code gt lt New PIN code gt P Pel o e lt PUK code gt o Unlocking of SIM card due to faulty lt New PIN code gt EY lt New PIN code entered PIN code Max 8 digits 10 gt EEEEEE rematan EEEEEE remanra A CIC EN P A 6 Lo O A lt Alarm type gt P Activation of programmable alarm
3. Manual F lt EC II GSM Eng Art Nr 2135 Page 18 of 35 time is normally 3 5 years and it should be replaced after that If the products temperature range is exceeded it may influence the battery lifetime The battery in F lt EC II GSM contains substances harmful to the environment mainly lead and sulphuric acid Therefore scrapped batteries may not be thrown away with ordinary gar bage but must be disposed of in a responsible way Follow the regulations from the environ mentally responsible local authorities which are valid at the time of disposal As a rule the same procedure may be used which are applied for the disposal of car batteries because the F lt EC II GSM battery is designed in a similar way The F lt EC II GSM may not be used if the battery is not mounted and connected but the bat tery can be replaced during operation If battery is replaced during operation the battery alarm can be activated but the reset button S1 can reset the battery alarm If the battery is mounted with reverse polarity the equipment will not be damaged but a battery alarm will be activated After battery replacement it is recommended that the reset button S1 on the printed circuit board of the central unit should be used It will recharge the new battery completely and test it The battery can operate the equipment for at least 60 minutes as long as the current con sumption for various connected external units does not exceed the specifications
4. Reset button S1 7 2 Battery charging The built in battery charger checks that the battery is continuously charged and an empty bat tery is fully charged in a maximum of 14 hours The battery charger is temperature compen sated and has a limitation of current charging to prevent damages on battery when an empty one is mounted Manual F lt EC II GSM Eng Art Nr 2135 Page 19 of 35 7 3 Battery test The capacity of the battery is tested automatically every 14 day and the test can last up to 90 minutes depending on the condition of the battery The better the battery the shorter the test If the battery voltage by the battery test sinks below a certain level a battery alarm goes out The first battery test is made after 17 hours of operation No battery test is made during ongoing power failure An ongoing battery test is interrupted immediately if a power failure occurs or if battery voltage sinks down below a certain level 7 4 Battery alarm and reset alarm The F lt EC II GSM sends out a battery alarm to indicate that the battery is bad The Battery alarm is completely silent an active battery alarm is indicated by a light signal on the speech unit and on the central unit A battery alarm will be sent out at any of following occasions e Battery voltage is sinks below a certain level at a regular battery test If voltage has not reached a certain level after 7 hours of charging If battery is mounted with reverse polarity If a ba
5. type for lift alarm Can be from 00d to 99d 10d Manual F lt EC II GSM Eng Art Nr 2135 Page 34 of 35 No Programming sequence Function Def P9 o o lt Old code gt Change of F lt EC II GSM security lt New code gt lt New code gt P Reset all settings to factory mode 15 Contact information falt communications F lt Communications AB Umestan 903 47 Ume Sweden Phone 46 0 90 718 000 exchange Fax 46 0 90 718 048 Homepage hittp www faltcom se Service address Service department BL Elektronik AB Furuhedsv gen 1 952 31 Kalix Sweden Phone 46 0 923 667 20 Fax 46 0 923 125 40 Homepage http www bl elektronik com Manual F lt EC II GSM Eng Art Nr 2135 Page 35 of 35
6. if a new speech connecting alarm is made or if a call is made to F lt EC II GSM during this interval 8 2 4 Battery alarm receiver In normal cases the 1 alarm receiver is used as battery alarm receiver together with alarm code 1 It is possible to choose to send all battery alarms to a dedicated battery alarm re ceiver with Pla to e lt Phone number max 20 digits gt P Enter alarm code for battery alarm with CCOO lt Alarm code max 10 digits gt P Test the battery alarm receiver function in programming mode by enter E L OE Manual F lt EC II GSM Eng Art Nr 2135 Page 25 of 35 After completed programming mode the F lt EC II GSM immediately call the battery alarm receiver This test alarm is called out as a speech connecting alarm Push following sequence to finish sending all battery alarms to a dedicated battery alarm re ceiver QOTOQ 8 2 5 Simple phone acknowledgement When the F lt EC II GSM sends an alarm to a phone or a mobile an acknowledgement must be made on the receiving phone If there is no acknowledgement F lt EC II GSM will call the next programmed alarm receiver after thirty seconds See section Alarm to a phone There is a possibility to simplify phone acknowledgement for alarm receiver by activating either of the functions Simple phone acknowledgement or Disconnection of acknowledgement Read more under respective section Simple phone acknowledgement means that alarm receiver can push
7. information can be found Product surveys Market material Updated user manual Software and available updates Installation and maintenance instructions Contact information http www faltcom se 3 4 Repair return procedure Falt Communications AB only accepts returns which are accompanied by a completed Service Card which can be found in the section Service form This form can also be downloaded from www faltcom se If the product is purchased from one of our distributors the buyer must first contact the distributors for assistance Please note that the battery cannot be enclosed at return of goods All returns must be sent well packed with freight paid to the address Service department BL Elektronik AB Furuhedsvagen 1 952 31 Kalix Sweden Repaired products are sent to customers as a regular post parcel with freight paid on the as sumption that the product is included by warranty If the investigation shows that there are no defects on the returned product the customer is charged with a service fee and freight charge The customer can ask for a quotation for repair of product not covered by warranty Manual F lt EC II GSM Eng Art Nr 2135 Page 5 of 35 3 4 1 Service form SERVICE FORM Used for equipment of type DC DC converter Emergency power supply KONE Direct II KONE Direct III KONE Direct GSM F lt EC II F lt EC II GSM Return the equipment and Service department a complete service form to
8. 400V e g in the lift engine room Never disconnect a cable before you have made sure that it is not connected to any voltage After instal lation the low tension cables SELV have to be bundled together so they cannot come near live wire or parts of the mains voltage if a connection loosens from termi nal block 6 1 Installation of central unit The Central unit is most easily mounted on the roof of the lift either in a lying or standing posi tion Ensure that is possible to connect both to the electric system and the alarm button from the site of erection in the lift car The central unit should not be mounted on top a lighting fit ting that can raise ambient temperature and therefore shorten the lifetime of the battery The enclosed mounting screws or other suitable screws should be used Standing installation Lying installation It is very important that the F lt EC II GSM has the best possible GSM signal to prevent communication disturbances Find the best possible position before mounting of the central Manual F lt EC II GSM Eng Art Nr 2135 Page 13 of 35 unit Place a standard mobile phone in the imagined site of erection make a speech connect ing call and run the lift slowly through the whole lift shaft If there is a disturbance or interrup tion of the call choose another position and do the whole procedure again Make sure that the same operator is used which is intended to be used by the F lt EC II GSM Bat
9. BL Elektronik AB Furuhedsvagen 1 SE 952 31 KALIX Sweden Tel 46 0 923 667 20 Fax 46 0 923 125 40 46 0 90 71 81 12 Support issues Sender Company name Date Address Lift number ID number Zipcode city Lift phone telephone number Country Mechanic Contact person Telephone Mobile Order number Note that not all information below is applicable for all products Only complete the part valid for the product which will be sent to service The problem was discovered E When mounting After an operation time of about weeks The lift phone was power supplied by External C The telephone line C DC DC converter C Emergency power supply 230 VAC The lift phone LJ Was single mounted Shared telephone line with number of other lift phones The lift phone was Connected via a switch _ Connected on a direct telephone line PSTN The telephone line to the lift car was _ A separate cable _ Inside the ordinary lift cable Error description Miscellaneous information 2004 02 09 v1 3 Manual F lt EC II GSM Eng Art Nr 2135 Page 6 of 35 4 General 4 1 Contents of packing Packing for F lt EC II GSM Part No 2129 contains following parts Central unit Part No 2117 includes Manual and installation instruction this document Mounting screws Cable tie Modular cable 3 meters GSM antenna Speech unit Part No 2127 includes Frame Mo
10. LED B Green LED indicates function Of GSM MOdNU E cooooccccccncncconincconnno 30 11 1 3 LED C Two coloured LED red green with following information 30 11 2 Two coloured LED red green of the speech unit occccooccncccccccnccnccncononcnnonnnconcnnanonos 31 12 FUSES IN CENTRAL UNIT cc coa cata 31 13 TROUBLESHOOTING brcsunsstregontssbonstnsetsstodasarsdvknteb lia 32 13 1 F lt EC II GSM is not possible to prograM cccoocnccccncccccncconcnccnnnnnoncnnnonnnononcnonononononos 32 13 2 F lt EC II GSM is unable to Call Up cooccccoccnccoccnccccnnccocnnonocnnnnncnnonononnnnnnnonononononos 32 13 3 F lt EC II GSM calls up automatically at power 0ON ooccccoccncccccncccccnccocnncnncncnononononos 32 13 4 Whistling sound from loudspeaker at alarm SEQUENCE smssmnsrrsssrrssrrsrrrerrrenrrrnrrrrn nero r ana 32 13 5 Disturbances during voice COMMUNICA IONS oonccccoccccnnccncoccncnnnnnonncnnnnncnnonannnnnannnnnnnos 32 1320 Technical SUDDO era letrada cintia place 32 14 PROGRAMMING OVERVIEW ccoo dd 33 15 CONTACT INFORMATION cta tic nn ARR A ARA ARR ARR RAR R RAR R ARR RR ARR RAR R RAR RR RAR RA 35 Manual F lt EC II GSM Eng Art Nr 2135 Page 3 of 35 2 Notes We would like to thank you for placing your confidence in F lt Communications AB and are convinced about the choice of one of our security products will fulfil your expectations In or der to operate this F lt EC II GSM correctly
11. When mains returns the emergency light switches off To extend the operating time on the lift phone the emergency light switches off after 60 minutes The emergency light also switches off if no lift alarm is made within 20 minutes of mains fail ure Output is adapted for an emergency light on maximum 12V 5W Use the lifts existing emer gency light if it is not exceeds 12V 5W or contact your local distributor or Falt Communica tions AB for more information This output is protected with fuse as protection against possible short circuit see section Fuses in central unit 6 1 8 Intercom For communications between lift machine room and the lift car there is a possibility to connect an intercom phone to the central unit Most types of phones can be used as long as they are approved for connection to the telephone network TBR21 approval A connection is made automatically when the receiver is lifted and the connection is cleared when the receiver is replaced If a speech connected lift alarm is made at the same time as the intercom is connected the intercom is connection is broken and the lift alarm calls out as usual The Intercom is reconnected when the alarm call is finished if the receiver is still off the hook If an incoming voice call is made at the same time as the intercom is in use the intercom will be disconnected and the voice communication starts The Intercom is reconnected when the alarm call is over if the receiver is still o
12. al and ergonomically reasons it is recommended that all programming is done at e g at a desk before the F lt EC II GSM is mounted in the lift All programming which is done in the F lt EC II GSM is stored in the SIM card and will remain in the F lt EC II GSM even after it has been dead This means that if you change the F lt EC II GSM at for example a repair no new programming is needed apart from the PIN code as long as the same SIM card as before is used The keys on the keyboard of the speech unit have the following functions Programming Starts and end of an all programming sequences Sequence receiver Used when programming more than 2 alarm receivers Alarm receiver 1 Phone number to alarm receiver 1 Alarm receiver 2 Phone number to alarm receiver 2 Code Alarm code 1 Used for alarm receiver 1 3 4 5and 6 Code e HE E e l Alarm code 2 Used for alarm receiver 2 The other keys have the same function as on a standard telephone At each time the keys are depressed in programming mode a short tone is heard and after each programming sequence there is a 4 tone for successful and a 1 tone for unsuccessful programming Manual F lt EC II GSM Eng Art Nr 2135 Page 21 of 35 The F lt EC II GSM can also be programmed remotely Contact your local distributor or F lt Communications AB for more information 8 1 Standard functions Below follows a description of the most frequent programmin
13. central unit with relay function If one of the up to three alarm buttons is pressed down the relay output is activated and will remain activated as long as the alarm button is activated The relay output is not affected by programmed alarm button delay or if filter function is activated The relay output is of the type normally open NO and may be on load with maximum 50V 1A This output can be used to activate an alarm bell if the lift existing alarm button not is of dou ble breaking type See section Output 12V DC 6 1 11 Filter input To reduce the number of false alarms lt is possible to connect the F lt EC II GSM to the con trol equipment of the lift via the built in filter input By letting the lift decide if lift alarm should dial out the number of false alarms can be reduced For this to function the control equipment of the lift must be able to generate a signal that the F lt EC Il GSM can use Possible addi tional connected alarm buttons ALBU are not affected by this filtering The function is activated with a special programming sequence see section Programming 6 1 12 Loop amplifier To enable passengers with impaired hearing to communicate with alarm centre there is a pos sibility to connect a loop amplifier Contact your local distributor or Falt Communications AB for information about approved loop amplifier to be used with F lt EC II GSM The loop amplifier output on F lt EC II GSM has a signal level of 50 100 mV an
14. d an internal impedance of 1 KQO Suitable load impedance is 10 kQ The output can be short circuited with out causing any damage The loop amplifier must work during power failure Connect it to a power supply that is work ing during power failures It can be connected to the F lt EC II GSM s own 12V output only if it fulfils the requirements which are described under the section Output 12V DC 6 2 Installation of speech unit Select a suitable place for the speech unit Avoid installing it in a corner or behind anything that may reflect the sound This might lead to acoustic feedback instability between the loud speaker and the microphone Make sure that you do not saw or drill in existing cabling when you make holes Manual F lt EC II GSM Eng Art Nr 2135 Page 17 of 35 6 2 1 Frame mounting Mark and pre bore the holes for the speech unit frame at suitable position according to en closed drill template Drill the holes for the modular cable to reach modular contact on speech unit The modular cable cannot be led between the keyboard and the lift wall because the dis tance between the keyboard and the wall is too small when the speech unit is screwed into the frame This requires the hole for the modular cable to be drilled next to those of the edges of the frame see the enclosed drill template Mounting of speech unit in the enclosed frame 6 2 2 Recessed mounting There is also a possibility to mount the speech unit withou
15. d so that all people are aware of the possibility of alarm calls Likewise the special func tions which exist for certain buttons on the phone should be marked At an alarm situation it is not certain that a separate instruction is available The most impor tant button to learn is 4 to acknowledge the alarm and set up the call Manual F lt EC II GSM Eng Art Nr 2135 Page 28 of 35 TERMINATE ALARM An incoming alarm call from F lt EC II GSM gives a tone chirp every 3 second when the re ceiver is lifted t is important that everybody is aware of the opportunity with alarm calls 1 2 Acknowledge the alarm with 4 ACKNOWLEDGE A voice communications call is then set up and speech exchange is automatic as in a normal telephone call If the automatic speech exchange is not satisfactory you can change to manual speech exchange 8 TALK and 7 LISTEN Revert to automatic speech exchange by pressing 4 ACKNOWLEDGE Is the function alarm mode activated and the product is in active alarm mode you can finish it by pressing the key 5 TERMINATE ALARM MODE The call is automatically disconnected A call will be disconnected automatically three minutes after the last key pressing With thirty seconds to disconnection a warning tone will be heard every 5 second To prolong the call press 4 ACKNOWLEDGE End the alarm call by pressing O END If the alarm is ended with time disconnection replaced receiver or lost c
16. e Q EN GE P gt F lt EC II GSM immediately leaves the programming mode and calls alarm receiver 2 If there are more alarm receivers test them by substituting 72 in the sequence above by sls sels f s and s 6 s 8 2 Special functions Below there is a description of all other programming sequences which can be used with Falt EC II GSM 8 2 1 Automatic test alarm By activating the function automatic test alarm F lt EC II GSM will call an alarm receiver with certain interval to check the connection Note the function automatic test alarm may only be programmed if the function is ordered by the alarm receiver Select the required test interval between 1 to 9 days RECECE lt Enter alarm code for the test alarm receiver with P 3 o o 3 lt Phone number max 20 digits gt P Enter alarm code for the test alarm Pls o 1 lt Alarm code max 10 digits gt P The first regular test alarm calls 5 minutes after completion of programming mode After that the next test alarm calls after 10 hours and then next test alarm calls out after programmed test interval The delay in 10 hours is there to move test alarm calls to the evening when the tariff usually is lower than daytime Test the test alarm function by in programming mode enter P ls lo lo e Programming mode is completed automatically and the Falt EC Il GSM sends immediately to the test alarm receiver Note that the test alarm is not
17. e GSM operator is offering that kind of service The person who makes an alarm from the lift could be in a panic situation and you cannot assume that the person can tell you where he or she is The person can also talk a foreign language or having speech difficulties Because of this we recommend always letting lift alarms go to automatic alarm receivers which with help of the programmed alarm code can identify the lift If an alarm is sent out but not acknowledged within 30 seconds the call is disconnected and the next programmed phone number called after 10 seconds Totally 10 attempts are made and if all fail the F lt EC II GSM returns to standby The F lt EC II GSM calls the 1 alarm receiver and then the next programmed alarm phone number If for example three alarm numbers are programmed the calling sequence 1 2 3 1 2 3 1 2 3 1 will be made Is there only one alarm phone number programmed all calling attempts are made to that phone num ber If an alarm button is pushed this has higher alarm priority during the calling sequence The F lt EC Il GSM will start again with calling attempts Alarm button priority is in descending order Alarm button 1 Alarm button 2 ALBU amp Alarm button 3 ALBU 9 1 Alarm to a phone All tone dialling telephones can work as alarm receiver The keypad of the phone is used to control alarm reception and to acknowledge the alarm Note that phones which are used for alarm reception should be marke
18. e gt x lt new PIN code gt P Manual F lt EC II GSM Eng Art Nr 2135 Page 26 of 35 8 2 9 Filter input To reduce the number of false alarms there is the possibility to connect F lt EC II GSM to the control equipment of the lift via the built in filter input By letting the lift decide if lift alarm should dial out you can reduce the number of false alarms In order to activate this it is nec essary for the control equipment of the lift to be able to generate a signal which F lt EC II GSM can use Check carefully in the documentation of the lift Other connected alarm buttons ALBU are not influenced by this filtering It is possible to select two different types of activation active high and active low A high sig nal is defined as gt 4V DC and a low signal is defined as lt 3V DC If for example active low is programmed and a 12V DC signal from the control system of the lift is connected to the filter input the F lt EC II GSM will filter out all alarm attempts from the alarm button If the lift stops because of an error and the control equipment of the lift makes the signal to the filter input to be low the next alarm attempt will result in an alarm call Activation of filter input as active high is done with ee ls o lo le Activation of filter input as active low is done with ee ls lo 1 le Filter input is disabled with e e s o o e 8 2 10 Programmable alarm type F lt EC II GSM has a number of pre d
19. e is programmed the SIM card will be locked after 3 attempts 8 1 4 Setting for closing and breaking alarm button Breaking function NC is pre programmed If the alarm button in the lift is a closing type NO F lt EC II GSM must be programmed for this with EECETCE Reset to alarm button with breaking function NC with CEC TOE Note that possible other external alarm buttons ALBU which are connected are not con cerned by this programming Manual F lt EC II GSM Eng Art Nr 2135 Page 22 of 35 8 1 5 Change of time delay for alarm button You can change the time that the alarm button must be pressed down before an alarm is acti vated The default time is 5 seconds but this time may be changed between 1 and 30 sec onds Note that the selected time must always be shorter than the time posted next to the alarm button in the lift car The delay is selected with Pp o 5 3 e lt Lim e in Seconds 1 30 gt P The time delay does not include other connected alarm buttons ALBU but for them the alarm calls out immediately at activation Note that it is only the delay for activation which is programmed and the speech connection will need more time to establish 8 1 6 Setup of alarm number and alarm code For connection to an alarm centre the phone numbers and alarm code specified by that alarm centre must be used The alarm code tells the alarm centre which lift and which building the alarm comes from Note tha
20. efined alarm types for different types of alarms Follow ing alarm types are found Alarm type Decimal Hexadecimal e Liftalarm 10d OAh e Battery alarm 17d 11h e Reset of battery 12d OCh e Test alarm 26d 1Ah However there are certain types of automatically alarm receivers which cannot handle incom ing lift alarms with alarm type 10d With a programming sequence the alarm type for lift alarm is changed freely Ps o o lt Alarm type gt P The alarm type shall always be entered decimal and with two digits 00 99 Reset of original alarm type 10d is done with P le lo lo e 8 2 11 Change of security code To be able to remotely programme F lt EC II GSM you must know the security code of F lt EC II GSM At delivery the code is pre set to 1111 but can be altered with the following se quence Manual F lt EC II GSM Eng Art Nr 2135 Page 27 of 35 px 9 o o x Sou code gt Xx lt new code gt Xx lt new code gt P where lt old code gt and lt new code gt correspond to the old respective the new four figured security code 9 Alarm reception It is recommended that all alarms from F lt EC Il GSM should be sent to a manned alarm centre In exceptional case it is possible to let a phone or mobile to be an alarm receiver With alarms to a phone it is not possible to identify F lt EC Il GSM with the programmed alarm code Instead for example number display can be used to identify the calling F lt EC II GSM if th
21. falt communications Falt EC II GSM Manual and installation instructions Version 1 7 Created 2003 10 30 Updated 2004 04 29 Manual F lt EC II GSM Eng Art Nr 2135 Page 1 of 35 1 Table of contents T FABEE OF CONTENTS ozeni naa a a es 2 2 NOO e a a en Oe ere ee do ee ide SEE 4 BODY EI OG sedan CU Om II nateuaent eee 4 Sil DESCUPUORF TRO OO CS ria ort Orr a iO SR RN Ng TS SE ANA Re 4 Di MVA TAL Sason a a a RSA cua hauuntigdivaweuinisciuaine SN N S D A O cece eats A ctor eset ay ebence secs 5 on REPA return Procequre aiii odos 5 OATS CRVICS N Saas sees aE a T E E as E E E O EE 6 AGE NERAL aen a a a 7 A TContents of Da KING aii heel ae lc IS T O 7 dil PAC CO SS ONO ii ape sa o ame NN NR 8 A E AE IEE 1E A E A A AE E duon OR E A SNR 8 4 2 1 Physical dimensions and fUNC TONS coooncccconnnnccoonnnconononnononcnnonnaronnnnannnnonancnnonnanonos 8 4 22 CONNECHONS ON CONTA UE es 9 5 INTRODUCTION ei oat occas o lo aie ian at 10 ye PON WONG orei eaaa nasa salty aan i or aren ae a ges NA ARR AE nita 10 02 PROGUCEOSSCHDUOM a ai id Dada 10 5 2 1 Overview of F lt EC II GSM functiOnNality ooooonccccconconocononnonononnononcnnonnaronnnanos 11 O INSTALLATION cout tado rara 13 6 1 Installation Of central unit cooccccconcnccccnnnoconnconnnnnnonnononnnonnnnonnnnnnnnnnnonnnnnonnnnononenenonos 13 6 1 1 POWEES UI E 14 6 1 2 Installation Of SIM CArd oooooncccccncccccnnonocononoconononnononononononononnnnonnnon
22. ff the hook If the intercom receiver is off the hook at the same time as a speech connecting alarm call is made the intercom is not connected until the alarm call is finished Test alarm and battery alarm functions as usual even if intercom is in progress Intercom is not affected if the product is in alarm mode When the intercom is active a tone is heard in the speaker of the speech unit every 10th second and is indicated by light signals both in speech unit and in central unit Remote programming cannot be done at the same time as the intercom is in progress Manual F lt EC II GSM Eng Art Nr 2135 Page 16 of 35 6 1 9 Output 12V DC This output always supplies 12V DC even if the product is operating on battery as long as the emergency power supply is not shut off to protect the battery against deep discharging The maximum load on the output is 100 mA continuously to not influence the battery opera tion time of F lt EC II GSM For shorter periods it can be on load with up to 500 mA e g for the external alarm bell If the lift does not have a double breaking alarm button this output to gether with the build in relay output on central unit can be used to activate an external alarm bell which can be connected in series with relay output and 12V DC output The output is protected with fuse against possible short circuit and overload see section Fuses in central unit 6 1 10 Relay output There is a potential free connection on the
23. g sequences which will be used by programming the F lt EC II GSM A number of special functions are presented below the next section 8 1 1 Setup of programming mode The F lt EC II GSM can be programmed only after it has been set to programming mode which is done by pressing and hold down the button P or the button 0 for three seconds Active programming mode is indicated by a 4 tone from the loudspeaker of the speech unit and a flashing red green LED both from the speech unit and central units The flashing con tinues as long as F lt EC II GSM is in programming mode The programming mode is automatically disconnected after 30 seconds if no keys are p ressed It is possible to interrupt the programming mode manually by pressing CEE 8 1 2 Reset of Falt EC II GSM If the F lt EC Il GSM is moved to another building or if the alarm numbers are changed or if the unit has been incorrectly programmed the best thing might be to simply delete all old set tings The PIN code is not deleted Reset all setting in F lt EC II GSM with Pee la lo e 8 1 3 Programming of PIN code In order to be able to call out alarm calls from F lt EC Il GSM the PIN code of the SIM card must be programmed It is done with the programming sequence P Ge a o o e lt PIN code gt P Where lt PIN code gt correspond to the PIN code of the SIM card Note that at every start up the product tries to unlock the SIM card If an incorrect PIN cod
24. h switchover Duplex or simplex Test alarm Interval between 1 9 days Battery alarm Automatically Alarm reception Contact your local distributor for information of alarm centre can re ceive CPC protocol All standard telephone including mobile phones can also work as an alarm receiver Manual F lt EC II GSM Eng Art Nr 2135 Page 8 of 35 4 2 2 Connections on central unit Central unit connections below marked Function 1 Power supply 2 Speech unit 3 Antenna connection 4 Emergency light 5 6 7 8 Alarm button 1 Alarm button 2 ALBU Alarm button 3 ALBU Intercom 9 Filter connection 10 12VDC output 11 Relay output 12 Loop amplifier Connection 2 pol screw terminal block RJ 45 FME f 2 pol screw terminal block 2 pol screw terminal block 5 polig SPOX 2 50 mm 5 polig SPOX 2 50 mm 2 pol screw terminal block 2 pol screw terminal block 2 pol screw terminal block 2 pol screw terminal block 2 pol screw terminal block Manual F lt EC Il GSM Eng Art Nr 2135 Data 230V AC 50 60 Hz Max 12V 5W Adapted for Part No 2121 22 Adapted for Part No 2121 22 For standard telephone according to TBR 21 Optional active high low Nominal load 100 mA Max 500 mA Max 50V 1A Signal between 50 100 mV 1 kQ impedance Page 9 of 35 5 Introduction 5 1 Foreword We recommend a carefully reading of this user manual before F lt EC II GSM is put into op eration t
25. lift car to be reached by a trapped technician When someone presses the alarm button for more than 5 seconds the alarm calling process is activated in the F lt EC II GSM Time delay is programmable between 1 and 30 seconds F lt EC II GSM can call up to six Manual F lt EC II GSM Eng Art Nr 2135 Page 11 of 35 different alarm receivers or ordinary tone dialling telephones Two alarm numbers can be pro grammed to use a special alarm code to identify F lt EC II GSM in an alarm centre 100 mm LED 100 mm j Loudspeaker Microphone Speech unit front and rear side Keypad The rear side of the speech unit has a keypad for programming call numbers function selec tion and testing All such settings are made during the installation and normally no subse quent changes are required It is however also possible to program the F lt EC II GSM re motely Contact your local distributor or F lt Communications AB for more information To contact possible trapped persons there is the possibility to phone in to the F lt EC II GSM Normally it is open for incoming calls but the function can be shut down or programmed so that it only allows incoming calls only after a lift alarm has occurred The built in emergency power supply monitors and tests the battery regularly If the battery is bad and needs to be replaced a battery alarm is sent to an alarm receiver It is also possible to manually reset a battery alarm with a button on the prin
26. munications There may be problems with GSM coverage in the lift shaft Try to move central unit or mount it standing to improve the position of the antenna Another type of antenna might possibly be used In worst case the GSM covering so bad that a fixed telephone line must be used Con tact your local distributor or Falt Communications for more information 13 6 Technical support Further technical support for F lt EC II GSM is available from your local distributor or via the homepage www faltcom se Manual F lt EC II GSM Eng Art Nr 2135 Page 32 of 35 14 Programming overview Below follows an overview of all programmable functions in F lt EC II GSM In the column to the right are possible normal values and normal settings specified No Programming sequence Function Def 1 Y ECE Petonotorgamming made E 2 lt Phone No gt a Programming of phone number to primary alarm receiver Max 20 digits Programming of phone number to secondary alarm receiver Max 20 digits Test of secondary alarm receiver o a oe lt Alarm code 1 gt a Programming of alarm code 1 Max 10 digits a ew lt Alarm code 2 gt a Programming of alarm code 2 Max 10 digits a s lt 3 6 gt s lt Phone No gt P Programming of phone numbers to alarm receiver 3 to 6 Max 20 digits ECs CEE PELECE o ECCECE P A O 5 Ey lt 1 30 gt a Delay time to activate alarm input 1 X Unit in seconds
27. o ensure that the product is used safely and effectively F lt EC II GSM should only be used in the context for which it is intended All other form of usage will be considered as being solely the users own risk Only qualified persons are per mitted to install program and start up this product Start up is only allowed after the product has been properly installed As a consequence F lt Communications AB disclaims all respon sibility for possible defects operational disturbance accidents etc caused by lack of knowl edge or carelessness from the user The same principle is valid for all not approved changes to the product F lt EC II GSM uses a GSM standard for mobile telephony The product can consequently not be used in areas without satisfactory coverage Since the GSM system is using radio based technology disturbances may occur when using other telephone or radio sets which are not sufficiently protected against radio waves The product is following valid security stan dards for exposure of electromagnetic radiation F lt Communications AB reserves the right to make changes in the product for functional or commercial reasons The company is not forced to immediately update reference manuals F lt EC Il GSM cannot be used e On places where there are an explosion hazard e On places where chemical substances are used in a greater extent with particu lar regard to safety rules for environments filled with unstable gases or fumes
28. on any of the buttons 0 9 to acknowledge the call Disconnection of call is made by pushing the button or by re placing the receiver The call is extended 180 seconds with any of the buttons 0 9 Manual speech switchover does not work The function is activated with P eee The function is disabled with ete lo le 8 2 6 Disconnection of acknowledgement It is possible to completely disconnect the acknowledgement function It means that receiving phone only have to lift the receiver Disconnection will be made when the receiving phone pushes x or replaces the receiver Maximum conversation time is 180 seconds and cannot be extended Manual speech switchover does not work Function is activated with AREA The function is disabled with Peele 8 2 7 Change of PIN code on SIM card Change PIN code on SIM card with the following programming sequence P 4 1 o 4 lt old PIN code gt x lt new PIN code gt X lt new PIN code gt P 8 2 8 Unlock the SIM card If the wrong PIN code is entered the SIM card will lock after three faulty trials F lt EC Il GSM will make an attempt each time it is connected to mains or when a new PIN code is pro grammed To be able to unlock the SIM card you must have access to the SIM cards PUK code The SIM cards PUK code is stated in the documents from the GSM subscription The SIM card is unlocked with following programming sequence P 4 2 o lt PUK code gt lt new PIN cod
29. onononnnnonaninonaninnns 15 6 1 3 CONNCCHOMN OF DA MOV ii 15 AC SRS A ee 15 6 14 5 Connection OF Ss PEC CA UNN serre A A Ai 15 A A ANY A 15 OA LEMON MOE A 16 A be sco eal es oes atest ease SNS enc SNR NGE Sacro aeee cee anand 16 OTD OUD UE TLV DO resonera f raren gren ete ain hdc ata NaN ocean ee st ea cad oe a 17 6T TOROV QUIDU Ls ias 17 ARE SNR RS Sr SRA NNE SNR a NRA RUNN aa 17 OPT ZL LOODAME na r o Ma Eat sete a canes 17 6 2 Installation Of Speech Uta tds 17 6 2 1 Frome MIA A diia 18 0 2 2 Recessed MOUNT A to 18 6 2 3 Mounting behind button and display plate occooocococnoccnncconononnnnornonanonnanons 18 T EMERGENCY POWER SUPPLY cuota a 18 A A O NR 18 fa Batey charging iaa a idas 19 Ped DAUCIY LOSE A rdr NN sd 20 7 4 Battery alarm and reset alarWM oocccocnncconnnccconnccnononnnnnconannnnnancnnnnnnnnnnnnnnnnnenunncnnanos 20 9 PROGRAMMING tati e aa decai 21 9 1Standard UNCUONS arc idos 22 8 1 1 Setup Of programming MOJO ooooccnococcnccccccconcnononononononononnnnonononononononononnnnonaninonaninnns 22 8 1 2 Reset of Falt ECI GSM ala 22 8 1 3 Programming of PIN code mssooeressrrssrrsrsrressreerrrerrrrr snar rr rsr snar rr n rr rar RKA RAKA RAKA RR ARR RKA Ran 22 8 1 4 Setting for closing and breaking alarm button oocccocncccccnnccccnnocononononnononononaninnns 22 Manual F lt EC II GSM Eng Art Nr 2135 Page 2 of 35 8 1 5 Change of time delay for alarm buUttON sererrrrrerrrrrrrrrrer
30. ontact and either Simple phone acknowledge or Discon nected acknowledge is programmed the F lt EC II GSM will make a new alarm call to the next programmed alarm receiver lf you want to forward the alarm to the next alarm receiver press 2 FORWARD Alarm is terminated and F lt EC II GSM calls next programmed alarm receiver Note that all alarm receivers should practise the alarm handling procedure 10 Calling the Falt EC II GSM If answering function is activated or if alarm mode function is programmed and F lt EC II GSM is in active alarm mode it is possible make a call to F lt EC II GSM from a tone dialling phone or a mobile according to the following 1 2 3 VE O Dial the number to the F lt EC II GSM F lt EC II GSM answers after the first signal with a 4 tone Press 4 to activate voice connection connect duplex and prolong an existing call with 3 minutes If key 4 is not pressed within 30 seconds F lt EC II GSM is automatically disconnected Press 5 to terminate a possible active alarm mode Then the call is disconnected Press 7 to listen Press 8 to speak Press 0 to disconnect the call Manual F lt EC II GSM Eng Art Nr 2135 Page 29 of 35 The call will be in progress for 3 minutes or until disconnection with keys O or 5 Thirty sec onds before time is ended it is indicated with a tone every 5 second 11 LED indication Status information on F lt EC II GSM is indicated with LED light signals The
31. re is a two coloured LED on speech unit and there are three LED on central unit and one of them is two coloured 11 1 The three LED of the central unit F i k i A E i A ye A Lay 11 1 1 LED A Green LED indicates mains voltage Flashing sequence Green fixed light External voltage connected Switched off External voltage missing 11 1 2 LED B Green LED indicates function of GSM module Flashing sequence Green short flash Module connected to GSM net Green fixed light Network problem SIM card problem 11 1 3 LED C Two coloured LED red green with following information Flashing sequence Green short flash Normal state Green short dual flash Active alarm mode Green alternating on off Alarm have been registered call is in progress Green fixed light Speech connection intercom is in progress Red Green alternating Programming mode Manual F lt EC II GSM Eng Art Nr 2135 Page 30 of 35 Red Green Red short flash Battery alarm Red alternating on off Network problem SIM card problem Red short dual flash Base configuration is missing 11 2 Two coloured LED red green of the speech unit In speech unit there is a two coloured LED red green which gives the same information as LED C in central unit Speech connection intercom is in progress Programming mode Battery alarm Network problem SIM card problem 12 Fuses in central unit Four glass tube fuses are mounted in central
32. rm centre through the GSM network The central unit contains a printed circuit board with a GSM module and an emergency power supply with associated battery All external connections such as antenna alarm button s mains power etc are made to the central unit The visual part of F lt EC II GSM is the speech unit where the user only sees the lift phone as a discreetly designed panel with perforated screen plate for the loudspeaker and micro phone On the lift phone front plate there is a two coloured LED that indicates the alarm and the GSM network status The space saving design of the speech unit facilitates mounting within the lift car Loudspeaker microphone and keypad for programming are integrated in one single unit This means quick and easy installation as well as high reliability in operation The speech unit is mounted on the wall or on ceiling of the lift car which eliminates the need to make holes other than those needed for the modular cable Interconnection of the central unit and speech unit is very quick and simple since a standard modular cable is used Central unit Speech unit GSM net Alarm button Lift car Alarm centre F lt EC II GSM is activated with a standard alarm button in the lift or if required with a sepa rate alarm button It is possible to activate F lt EC Il GSM with up to two separate alarm but tons with built in microphones These alarm buttons are intended for mounting on top of or below the
33. rrrrrrrrrrrrrrrrrrrr rr rr nr rr neon nn 23 8 1 6 Setup of alarm number and alarm COAG ooccococcccconcccoccnccononocononoconnonononononononanonnns 23 8 1 7 Test alarm to test the installation oooococcncoocnnoocnoconnononocannonanconancononconanonannnns 24 9 2 SPeClal TUNG H NS dos 24 8 2 1 PAULOIMAHC TE ST Aar sis utsida turerna eee oe AS A 24 PLATS WO F A OR ene tt a oR 25 GLS A blot Ute agn ee ace att Date naire Nn Nere rer 25 8 2 4 Battery alarM LOCCIVEL c1cccccsccccnsecscnsecsensussencueceueuscseusensausensassensnsseneuetauusenseesenees 25 8 2 5 Simple phone acknowledgeMet ooocccocncoconococononoconnncocononononononnononononanononaronenaninnns 26 8 2 6 Disconnection Of acknowledgement occcoconccoconcnocononoccnnnnocononononononnnnonononanononaninnns 26 8 2 7 Change of PIN code ON SIM CArd ococooonccccccinocononoconnccocnnononnnnonononononononononanonnns 26 8 2 0 UNIOCK the SIM Cal d si 26 6 PA FIO INDU o lt dilo nl 27 8 2 10 Programmable alarm type A ada 21 02 1 1 Change OF SCCUMLY COIE daa 27 ALARM RECEPTON co sata o de o Re 28 AN vann sd Brinn been SNUTEN a ON ra a NDRAR e etna ON ENN AR V r 28 10 CALLING THE F LT EC Il GSM assi 29 HEEDINDICATION a O 30 11 1 The three LED of the Central unit ccoooccccoccncccnnccocnncconnnonacononanononanoconnnonannnonanonos 30 11 1 1 LED A Green LED indicates mains VO age cooccccconnoconinocononeconononononononnnos 30 11 1 2
34. s usually connected to a local bell and the other one used for the F lt EC II GSM The connections must be galvanic isolated Contact your local distributor or Falt Communications AB for more information Manual F lt EC II GSM Eng Art Nr 2135 Page 15 of 35 Note that the alarm button may have closing or breaking function Breaking function is pre ferred and is the default setting for the F lt EC II GSM If the alarm button has closing func tion the F lt EC II GSM must be programmed to handle this see section Programming If the lift does not have a double breaking alarm button the build in relay output in central unit can be used to activate an external alarm signal bell If the lifts existing alarm bell is not con nected to an emergency power supply it is possible to use the 12VDC output that is con nected in series with relay output Note that the current consumption of the alarm bell must exceed the declared value for the 12VDC output To avoid misunderstanding only one alarm button should be mounted in the lift car There is also a possibility to mount two extra alarm buttons ALBU with built in microphones on e g roof of the lift or under the lift car accessible for example to trapped lift technician Contact your local distributor or Falt Communications AB for more information 6 1 7 Emergency light It is possible to connect an emergency light to F lt EC II GSM which automatically switches on when the mains power is lost
35. speech connected To check if the test alarm has reached the receiver you have contact the alarm centre Push following sequence to disable automatically test alarm e e 3 lo o e Manual F lt EC II GSM Eng Art Nr 2135 Page 24 of 35 The Test alarm is sent out even if battery alarm is active and during battery operation If a test alarm fails next the attempt will be made after 10 minutes Totally 10 attempts will be made 8 2 2 Answer function It is possible to phone F lt EC II GSM to talk with the person who is in the lift Normally the function is activated but the function can be disabled with CHENG The function is reactivated with CHEW ey CC 8 2 3 Alarm mode If alarm mode function is programmed it means the F lt EC II GSM can only receive incoming calls when the alarm mode is active To activate the alarm mode the following conditions must be fulfilled e Alarm mode function is programmed e A lift alarm has been called out The active alarm mode can only be disabled by the phone which receives the lift alarm or from the phone which calls to F lt EC II GSM See section Alarm reception or Calling F lt EC Il GSM Alarm mode function is programmed with Pe ale Alarm mode function is disabled with EE CHEE An active alarm mode is indicated by light signals both in speech unit and in central unit The active alarm mode is automatically disconnected after 6 hours but will be extended up to 6 hours
36. t frame so called recessed mount ing Drill a hole in the centre of the selected place and then make a hole with a 86 mm rotary hole saw or drill See the enclosed drill template Mark the holes for the mounting screws and pre bore 6 2 3 Mounting behind button and display plate There is a special version of the speech unit which is specially designed for mounting behind a button and display plate This alternative is only possible if there is already a prepared space for a lift phone behind the button amp display plate Since the design of the display may vary we are not able to give exact mounting instructions here Keep in mind that the micro phone hole must be aligned with a hole in the display plate It might become necessary to drill a new hole For the best sound quality the distance between the speech unit front plate and the display plate should not exceed 1 mm 7 Emergency power supply F lt EC II GSM has an integrated emergency power supply that ensures the product works by mains failures by connecting the built in battery It also allows connection of emergency light and operation of possible external equipment such as external alarm bell or similar 7 1 Battery Only sealed lead acid batteries approved by Falt Communications AB may be connected to F lt EC II GSM Other batteries may cause danger to the user and or damage the F lt EC II GSM Damages caused by incorrect battery types are not included by warranty Battery life
37. t it is important that several numbers are programmed if it is not an alarm centre with constant manning The F lt EC II GSM is always programmed in the same way whether if it will call to an alarm central or to a telephone mobile An alarm code must always be programmed whether the F lt EC II GSM call should be to an alarm central or to a telephone 1 If required reset all old settings 2 Enter phone number for alarm receiver 1 lt Phone number max 20 digits gt P 3 Enter alarm code to alarm receiver 1 CH lt Alarm code max 10 digits gt P 4 Enter phone number to alarm receiver 2 lt Phone number max 20 digits gt P 5 Enter alarm code to alarm receiver 2 P E lt Alarm code max 10 digits gt P 6 For alarm receivers 3 6 use the keys ls 3 s s 4 s s 5 s and s 6 s instead of under item 4 These numbers automatically get the same alarm code as alarm receiver 1 Note Do not forget to test the function by making a test alarm Manual F lt EC II GSM Eng Art Nr 2135 Page 23 of 35 8 1 7 Test alarm to test the installation After completed the installation the F lt EC II GSM must be tested with a test alarm Press the alarm button in the lift car and check that the alarm reaches alarm receiver 1 To test that the alarm also reaches secondary receivers use the keypad on the back of the speech unit Check that the alarm reaches alarm receiver 2 by pressing programming mod
38. ted circuit board on the central unit The product cannot be used without a mounted and connected battery It is possible to connect the lifts emergency light to F lt EC II GSM which automatically turns the light on when the mains power is cut off When the mains return the emergency light is switched off In the central unit there is a 12V DC output which can be used for external equipments such as an alarm bell or a loop amplifier for hearing impaired people The output is connected to voltage even after power failure on the condition that the emergency power supply has not been disconnected from the battery to protect it against deep discharging To gether with the relay output on central unit these two outputs can be used for example to activate an external alarm bell The relay actuates every time any of the alarm buttons are activated There is a possibility to connect an intercom telephone to the central unit for communications between the lift car and for example the machine room of the lift Most telephones can be used but they must be approved for connection to the public telephone network TBR21 ap proved The intercom starts when telephone receiver is lifted and finishes when the tele phone receiver is hung up If a lift alarm should occur while intercom is in progress the lift alarm has priority and will disconnect the intercom Manual F lt EC II GSM Eng Art Nr 2135 Page 12 of 35 F lt EC II GSM can be set to send an a
39. tery connection Power supply 230 VAC SIM Card holder Relay output Max 50V 1A Emergency light Max 12V 5W Output 12VDC IEEE 8 GT S ALBU1 ALBU2 Extra alarm tton 1 and 2 GSM antenna connection button 1 and Alarm button Modular cable Filter input from speech unit Intercom Loop amplifier Connections in central unit 6 1 1 Power supply The central unit is intended for fixed installation to input mains The central unit must be con nected to 230V AC and be fused with maximum 10A to the input mains An easily accessible mains switch must be available for the input mains to the central unit Both the input conduc tors must be fixed together and anchored with a cable tie 10 mm from the terminal and be well separated from the printed circuit board low voltage parts Mains which is switched on is indicated by a green LED on the central unit see section LED indication Manual F lt EC II GSM Eng Art Nr 2135 Page 14 of 35 6 1 2 Installation of SIM card Mains voltage must be disconnected during this stage The SIM card is mounted in the holder in the upper right corner of the printed circuit board Make sure that the contact sur faces are facing downwards and that the holder is closed properly after mounting Please note that the address book in the SIM card must be empty because the address book is used as a memory during programming and existing numbers can destroy normal functionality 1 P
40. ttery cell has been short circuited If no battery is mounted If a battery alarm has occurred the F lt EC II GSM automatically sends out a reset alarm at any of following of occasions e A regular battery test has been done without any problems e The Reset button S1 on the printed circuit board has been activated If a battery is replaced after the F lt EC II GSM has sent a battery alarm you should reset the battery alarm by pressing reset button S1 If this is not done a reset alarm will be sent out at next regular valid battery test which can take up to 14 days Until then the product will send a new battery alarm each 12 hour as a reminder The F lt EC Il GSM has protection against deep discharging which protects from deep discharging damages at mains failure This means that if battery voltage sinks below a certain level during battery operation the battery will be disconnected and F lt EC Il GSM will be shut off The F lt EC II GSM will be restarted automatically at the return of the mains Normally the 1 alarm receiver is used as battery alarm receiver together with alarm code 1 However it is possible to send all battery alarms to a special battery alarm receiver See sec tion Battery alarm receiver Manual F lt EC II GSM Eng Art Nr 2135 Page 20 of 35 8 Programming All programming i e alarm numbers codes to be sent and various function selections is done with the keypad on the back of the speech unit For practic
41. ull lock back and fold up 6 1 3 Connection of battery The enclosed battery is mounted in the intended position in the enclosure of the central unit and battery terminals are connected to corresponding battery cable For polarity see picture in the section Installation of central unit Be sure not to mix up polarity Only batteries approved by Falt Communications AB of type sealed lead acid batteries may be connected to the Falt EC Il GSM Other batteries could lead to danger for the user and or damage F lt EC II GSM Damages caused by incorrect battery types are not covered by war ranty 6 1 4 GSM antenna The enclosed antenna is mounted in intended position in the chassis antenna contact on the external enclosure of the central unit If there is a problem with sufficient GSM reception im provement of the situation can possibly be achieved with another type of antenna Contact your local distributor or Falt Communications AB for more information 6 1 5 Connection of speech unit One end of the enclosed modular cable is connected to socket in the central unit and the other end is connected to the speech unit 6 1 6 Alarm button A two wire cable from the lift alarm button must be taken and the wires screwed to the central unit terminal block Fasten the cable with cable ties on the outside of the lift Note that the alarm button in the lift car is normally double breaking e made for two sepa rate connections One of them i
42. unit All fuses are 5 x 20 mm 250V AC Slow Littelfuse type 218 Replacement of fuses must be made with same type and value e F1 Secondary side of transformer 630 mA T e F2 Battery 2AT e F3 Emergency light 630 mA T e F4 Output 12VDC 250 mA T Manual F lt EC II GSM Eng Art Nr 2135 Page 31 of 35 13 Troubleshooting The most frequent problems and how correct them are set out below 13 1 F lt EC II GSM is not possible to program Check the following e Is SIM card mounted and PIN code correctly programmed e Is there external feed to F lt EC Il GSM e Is the fuse F1 broken 13 2 F lt EC II GSM is unable to call up Check the following e Is there GSM network coverage in the lift shaft e Are both alarm receiver and alarm code programmed 13 3 F lt EC II GSM calls up automatically at power on The lift phone s alarm button has closing function but F lt EC II GSM is programmed for an alarm button with breaking function or vice versa Enter programming mode and select cor rect type of alarm button See section Programming 13 4 Whistling sound from loudspeaker at alarm sequence If there is a whistling sound when voice communications is set up during an alarm this may be due to acoustic feedback Acoustic feedback may appear if the microphone and the loud speaker are installed too close to a flat surface causing the sound to rebound between them See section nstallation 13 5 Disturbances during voice com
43. unting screws Label Battery Part No 2003 Battery 12V 2Ah Content of packing Manual F lt EC II GSM Eng Art Nr 2135 Page 7 of 35 4 1 1 Accessories Following parts can be ordered separately from F lt Communications AB or from our distribu tors Surface mounting alarm button with double breaking function Part No 2042 External alarm button with internal microphone ALBU 5m cable Part No 2121 External alarm button with internal microphone ALBU 8m cable Part No 2122 Emergency light 12V 5W Part No 2112 Battery 12V 2Ah Part No 2003 Telephone handset for intercom Part No 2043 4 2 Technical data 4 2 1 Physical dimensions and functions Data Central unit Part No 2117 Speech unit Part No 2127 Size 185x200x75 mm 100x100x23 mm Weight excl battery 1780 g 280 g Operating temperature 5 C to 40 C 5 C to 40 C Air humidity 30 to 90 30 to 90 Enclosure material 1 25 mm AluZink 1 5 mm stainless steel vandal proof Emergency power Battery 12V 2Ah By Central unit Power supply 230V 0 1A 50 60Hz By Central unit Indication Three LED s one is two coloured One two coloured LED and sound Antenna External 50 O GSM Dual band 900 1800 MHz Installation On top of lift car Inside lift car Programming By keyboard on Speech unit or remote programming Alarm button One ordinary and up to two extra with internal microphone ALBU Protocol CPC Signalling DTMF Speec
44. utomatic test alarm to a dedicated test alarm receiver with an interval of 1 9 days The alarm is send soundlessly and tests the electronics and re ception quality of the F lt EC II GSM If the test alarm should not occur an alarm will be acti vated at the alarm centre and personnel can be sent to the lift to investigate and take care of possible defects To reduce the number of false alarms there is the possibility to connect F lt EC II GSM with the control equipment of the lift with the integrated filter input Then it is possible to filter out all alarms attempts from the lift if the function is normal which reduces the workload on the alarm centre For security reasons any external alarm buttons ALBU s are not included by the fil tering There is the possibility to connect a loop amplifier to the central unit which makes it easier for people with impaired hearing to hear what is said in the speech unit Check with your local distributor or F lt Communications AB for information about approved loop amplifier units to connect to F lt EC II GSM 6 Installation Only competent and qualified personnel may install the F lt EC II GSM Knowledge technical skill and correct equipment are required for safe and efficient installation Warning Mind your own safety when installing F lt EC II GSM You must never work in an open lift shaft without a safety harness Be extremely careful and break current if you work close to a voltage of 230
45. we would ask you to read this manual carefully 3 Copyright This document belongs to F lt Communications AB and may only be reproduced adapted or transcribed after written permission from copyright proprietor Copyright O 2003 3 1 Description of goods Hereby Falt Communications certifies that this product is in compliance with essential re quirements and with other relevant regulations that is evident of directive 1999 5 EG and the following standards Safety Article 3 1a in R amp TTE EN60950 1 2001 EMC Article 3 1b in R amp TTE EN301489 1 EN301489 7 RF Article 3 2 in R amp TTE EN301419 1 EN301511 Ume February 2004 Torbj rn Hornliden CEO F lt Communications AB Manual F lt EC II GSM Eng Art Nr 2135 Page 4 of 35 3 2 Warranty There is a 2 year warranty 24 months for manufacturing failure or material failure commenc ing with the delivery date Warranty does not include Incorrect or careless usage Damages caused by thunderstorms or air pollution Vandalism or damage Normal wear Emergency power supply battery Falt Communications AB reserves the right to determine if the product will be repaired or re placed Warranty ceases to be valid if defects occur due to incorrect use or other method of application or context that has been specified in this manual 3 3 Updates Visit our website to get access to the latest updates for market information and technical documentation Following
Download Pdf Manuals
Related Search
Related Contents
Archos Helium 4G 50b 8GB 4G Black 取扱説明書兼 保証書 "LEDフォグランプ Kit Ver.2" (平成21年11月)【PDF:5.17MB】 A l`affiche en ce moment: Zavig P5115 Installation guide LightSYS X-10 Output Expander Installation Guide User Manual 株 主 各 位 柴野恒雄 第66期定時株主総会招集ご通知 Kyocera Finecam SL400R User's Manual KDC-BT73DAB KDC-BT53U KDC Copyright © All rights reserved.