1. 10 To delete ALL users Note This isa dangerous Delete all users of Zone 1 0000 option so use with care Delete all users of Zone 2 0000 To unlock the door or change relay state For a PIN user Enter the PIN then press For a card User Read card For a card and PIN user Read card then enter PIN Relay Setting Pulse mode Toggle mode Pulse mode Factory default Pulse mode Door relay time For Zone 1 4 1 1 99 setting For Zone 2 4 2 1 99 The door relay time is between 1 99 seconds the factory default setting is 5 seconds 1 means Zone 1 2 means Zone 2 Toggle mode Toggle mode BS For Zone 1 For Zone 2 4 Door Alarm Acoustic Signal Door Bell Settings Door Open Detection switching off automatically Door Open Too Long DOTL warning When used with an optional magnetic contact or built in magnetic contact of the lock if the door is opened normally but not closed after 1 minute the inside buzzer will bleep automatically to remind people to close the door and continue for 1 minute before Door Forced Open warning When used with an optional magnetic contact or built in magnetic contact of the lock if the door is forced open or if the door is opened after 20 seconds of t
2. DC Open C I N O NIC PSB 1 12v or 24v DC Power Supply 240v 5 amp Fused Spur Supply PRESS O TO EXIT Ensure lock release is set to 12v or ia 24v dc operation before testing Optional exit button Common power supply for auto gate controller using Normally Open contact LNN V V VN RY RS NEY NO Bu A NA 12v or 24v DC PSB 1 Open C N O NC 12v or 24v DC Power Supply 240v 5 amp Fused Spur Supply Optional exit button To gate controller 6 Remarks the Zone 2 it can be used to operate a doorbell if there is no need to operate a second door The wiring to connect the doorbell is via NO2 and COM2 Press the R3K will send out a switching signal to the doorbell as long as you press the the doorbell will operate it will stop when you release the Relay operation Pulse mode and Toggle mode Both of the two relays can operate in Pulse Mode suitable for access control or Toggle Mode suitable for arming disarming alarms switching lights machines etc Every time a valid fob card or Pin is read input in Pulse Mode the relay will operate for the pre set relay pulse time Every time a valid fob card or Pin is read input in Toggle Mode the relay changes state and will not turn back until the fob card is presented or the PIN used Anti Tamper Alarm The R3K uses an LDR light dependent resistor as an anti tamper alarm If the keypad is removed from
3. added continuously without exiting programming mode Card and PIN Mode To set users for Zone 1 To Add a card and Pin user The PIN is any four digits between 0000 amp 99999999 with the exception of 1234 which is reserved Add the card as for a card user Press to exit from the programming mode Then allocate the card a PIN as follows Read card 1234 PIN PIN To change a PIN in card and PIN mode Method 1 Note that this is done outside programming mode so the user can undertake this themselves Read Card Old PIN New PIN New PIN To change a PIN in card and PIN mode Method 2 Note that this is done outside programming mode so the user can undertake this themselves ID number Old PIN New PIN New PIN To delete a Card and PIN user just delete the card 2 Read Card or 2 UserID To set users for Zone 2 3 1 2 The operation is the same as Zone 1 To set Card user only in this mode users can only be valid by card To set Card user only 3 1 0 Zonel 3 2 0 Zone2 Entry is by Card only
4. ID number is any number between 1 amp 1100 for Zone 1 and any number between 1101 amp 1200 for Zone 2 The PIN is any 4 8 digits between 0000 amp 99999999 with the exception of 1234 which is reserved Users can be added continuously without exiting programming mode To add a card user for Zone 1 To add a card User for Zone 2 1 Read Card 5 Read Card Cards can be added continuously without exiting programming mode To delete a PIN or a card user 2 User ID number for a PIN user or 2 Read Card for a card user Users can be deleted continuously without exiting programming mode To Unlock the door for Zone 1 or Zone 2 To unlock the door for a PIN user Enter the PINI then press To unlock the door for a card user Present the card Connection Diagram Examples Common power supply for magnetic lock Fail open power to lock ONY VY V V WN Kee sea dela Nyni A Bue A Gree 12v or 24v DC PSB 1 Open C N O NC 12v or 24v DC Power Supply N C or 3 240v 5 amp Fused Spur Supply PRESS Zo Qe TO EXIT Ag f Ensure magnetic lock is set to 12v or 24v dc operation before testing Optional exit button Common power supply for lock release Fail secure power to unlock N NV V VY V N OR SO Nyni AN Bu Agee 12v or 24v
5. KP KR3 Stand Alone Keypad amp Proximity Card Reader User Manual INTRODUCTION The KP KR3 is a two relay multifunction standalone access control keypad suitable for either indoor or outdoor use It is housed in a strong sturdy and vandal resistant Zinc Alloy electroplated case The electronics are fully potted making it extremely weather resistant and conforming to IP68 It supports up to 1200 users in a Card PIN or a Card PIN option The inbuilt card reader supports 125KHZ EM frequency card or key fob and the Pin length is 4 8 digits Both of the two relays can operate in Pulse Mode suitable for access control or Toggle Mode suitable for arming disarming alarms switching lights machines etc The R3K has many extra features including block enrollment backlit keypad These features make the R3K an ideal choice for door access not only for small shops and domestic households but also for commercial and industrial applications such as factories warehouses laboratories banks and prisons Features Weather resistant to IP68 Strong Zinc Alloy Electroplated anti vandal case Two relay operation Both relays can be programmed for 3 modes Card PIN Card PIN 1200 user capacity Zone 1 up to 1100 Pin amp Card holders Zone 2 up to 100 Pin amp Card holders Pin length 4 8 digits card type 125KHZ EM card key fob Can be used as a standalone keypad Pulse mode Toggle mode Block enrollment can enroll 1100 consecutive c
6. ards within 2 minutes Backlit keypad Adjustable Door Relay Output time Alarm time Door Open time Built in light dependent resistor LDR for anti tamper Built in buzzer Dual relay outputs for door opening door status detecting open door by button Red Yellow and Green LEDS display the working status Supports door bell connection For relay 2 12 24V AC DC power input Specifications Operating Voltage 12 24V AC DC User Capacity 1200 Keypad 12 keys 3 x 4 digits Card Type EM card key fob Card Reading Distance 3 6 cm Pin length 4 8 digits Active Current lt 60mA Idle Current 2545 mA Lock Output Load Max 2A Alarm Output Load Max 20A Operating Temperature 25 60 C Operating Humidity 5 95 RH Environment Conforms to IP68 Adjustable Door Relay time 1 99 seconds Adjustable Alarm Time 0 3 minutes Wiring Connections Electric Lock Exit Button DOTL External Alarm Dimensions H 128 x W 82 x D 28 mm Net Weight 650g Gross Weight 800g Packing List Name Quantity Remarks Digital Keypad R3K 1 User manual 1 Screw driver 1 Rubber bungs 4 6 27mm used for fixing Self tapping screws 4 3 5 27mm used for fixing Please ensure that all the above contents are correct If any are missing please notify the supplier of the KP KR3 Installation Remove the back cover from the keypad using the suppl
7. he electro mechanical lock not closed properly the inside buzzer and alarm output will both operate To disable door open 6 0 detection Factory default setting To enable door open detection For Zone 1 6 1 For Zone 2 6 2 You can enable the door open detection of only one Zone 11 Keypad Lockout amp Alarm Output options If there are 10 invalid cards or 10 incorrect PIN numbers in a 10 minute period either the keypad will lockout for 10 minutes or the alarm will operate for 10 minutes depending on the option selected below Normal status No keypad 7 0 Factory default setting lockout or alarm Keypad Lockout 7 1 4 Alarm Output 7 2 Alarm output time To set the alarm output time 8 1 3 1 3 minutes Factory default is 1 minute Acoustic Signal The acoustic signal can be set on or off When on the R3K will bleep when buttons are pressed when off the R3K will be in silent mode Normal status On 8 6 Factory default setting Acoustic signal Off 8 Z Change Zone 2 to Door Bell When no need to operate a second door Zone 2 can be set to operate the Door Bell The wiring is connecting the door bell to COM2 and NO2 Press the keypad will send the sig
8. ied security screwdriver Drill four holes on the wall for the screws and one hole for the cable Fix the back cover firmly on the wall with 4 flat head screws Thread the cable through the cable hole Use the supplied rubber bungs to waterproof the screw holes Attach the keypad to the back cover Wiring cable Color Function Description Grey amp Black GND Negative pole Grey Alarm Alarm Negative Yellow amp Black OPEN2 Request to Exit Button of Zone 2 Yellow OPEN1 Request to Exit Button of Zone 1 Brown D_IN Door status detecting Red AC amp DC AC amp DC 12 24V power input Black AC amp DC AC amp DC 12 24V power input Blue amp Black NO 2 Black amp White COM2 Green amp Black NC 2 Blue NO1 White COM1 Green NC1 Quick Programming Guide To enter the programming mode Master code 888888 is the default factory master code To exit from the programming mode x Note that to undertake the following programming the master user must be logged in To change the master code 0 New code New code The master code must be 6 digits To add a PIN user for Zone 1 To add a Pin user for Zone 2 1 User ID number 1 1100 PIN 1 User ID number 1101 1200 PINI The
9. if the Card or Pin user has been enrolled already you can not add it again The R3K will give a bleep as error Factory default setting Card or PIN mode To set users for Zone 1 3 1 2 To add PIN users 1 User ID number PIN The ID number is any number among 1 1100 The PIN is any 4 8 digits between 0000 99999999 with the exception of 1234 which is reserved Users can be added continuously without exiting programming mode as follows 1 User ID no 1 PIN User ID no 2 PIN To delete PIN users 2 User ID number Users can be deleted continuously without exiting programming mode To change the PIN of a PIN ID number Old PIN New PIN Repeat new PIN user Note This step must be done out of programming mode To add Card Users Method 1 This is an easy way to enter cards with auto generated ID numbers The ID number will start from 1 if no user has been programmed 1 Read card Card can be added continuously without exiting programming mode To add Card Users Method 2 This is the alternative way to enter cards using User ID Allocation In this method a User ID is allocated to a card Only one user ID can be allocated
10. nal to the doorbell Zone 2 8i 8 Factory default Doorbell 8 9 To remove the alarm To reset the Door Forced Open Read valid card or Master Code warning To reset the Door Open Too Close the door or Read valid card or Master Code Long warning 12 Reset Procedure Reset Alarm The alarm will sound for 3 minutes To reset present a valid user card or enter Master Code via the keypad Reset to Factory Default To reset to factory default power off then press and hold the button and power on release it after you hear two bleeps the LED will turn orange After 10 seconds it will turn red and bleep once to confirm factory default is successful Note Reset to factory default the user s card key fob information is still retained Delete all users Delete all users of Zone 1 Master Code 2 0000 Delete all users of Zone 2 Master Code 9 0000 13
11. the cover then the tamper alarm will operate Sound and LED indication Operation Status Red LED Green LED Blue LED Buzzer Zone 1 unlock Bright Short Ring Zone 2 unlock Bright Short Ring Power on Bright Long Ring Stand by Shines slowly Off Press keypad Short Ring Operation successful Bright Long Ring Operation failed 3 Short Rings Enter into programming mode Bright off Long Ring In the programming mode Bright Bright Exit from the programming mode Shines slowly Long Ring Alarm Shines quickly Alarm KP KR3 Detailed Programming Guide User Settings To enter the programming Master code mode 888888 is the default factory master code To exit from the programming mode Note that to undertake the following programming the master user must be logged in To change the master code 0 New code Repeat new code The master code could be any 6 digits number Setting the working mode 3 1 2 Zonel 3 2 2 Zone2 Set valid Card or PIN users Entry is by either Card or PIN Factory default setting 3 1 1 Zonel 3 2 1 Zone2 Entry is by Card and PIN together Set valid Card and PIN users Note When adding users
12. to a single card 1 ID number Card The ID number can be any number among 1 1100 To add a series cards users Block Enrollment The card number must be consecutive This operation is only for Zone 1 5 ID number 8 digits Card number Card quantity Card quantity is between 1 1100 Of the 8 digits card number it is the last 8 digits on the card To delete Card users by cards Note Users can be deleted continuously without exiting programming mode 2 Read Card The device can automatically identify the card of Zone 1 or Zone 2 To delete Card users by user P User ID ID This option can be used when a user has lost their card To delete card users by card input 8 digits Card number number Cards can be deleted continuously without exiting from programming mode To set users for Zone 2 3 2 2 4 To set Pin user for Zone 2 is the same as Zone 1 only the ID number is 1101 1200 for Zone 2 To set Card user for Zone 2 is the same as Zone 1 with the exception of adding Card users with auto generated ID numbers Method 1 as below To add Card Users Method 1 Auto generated ID numbers 5 Read Card Card can be
Download Pdf Manuals
Related Search
Related Contents
Uconnect Touch™ NucleoSpin® 96 Plant II (Core Kit) - MACHEREY OPERATOR / PARTS MANUAL Aquatic 4834CS-AW Installation Guide Manual do Proprietário Samsung NT540U3C-A5H User Manual (Windows 8) guide du Prêt entre Bibliothèques SMART™ RACE cDNA Amplification Kit User Manual brochure - Hitachi Construction Machinery Europe T'nB TSGREEN02 mouse pad Copyright © All rights reserved.