        TDAS PLUS Visual Status Indicator User`s Manual
         Contents
1.         1           12V PWR CONTROL EVENT    JJe          support dtsweb com 4 Rev  2    TDAS PLUS Visual Status Indicator User   s Manual June 2005    Basic Care and Handling    The TDAS PLUS Visual Status Indicator is a precision device designed to operate  reliably in dynamic testing environments  Though resistant to many environmental  conditions  care should be taken not to subject the unit to harsh chemicals  submerge  it in water  or drop it onto any hard surface     WARNING     Electronic equipment dropped from desk height onto a solid  floor may experience as much as 10 000 Gs  Under these  conditions  damage to the exterior and or interior of the unit is  likely     When transporting the unit  treat it as you might a laptop computer and you should  have no problems  When not in use or if shipping is required  we suggest that you  always place the unit in the padded carrying case originally provided with your system     The TDAS PLUS VSI is not user serviceable and should be returned to the factory for  service or repair     Shock Rating   All crashworthy TDAS PLUS systems are rated for and fully tested to 100  Gs  12 msec  duration  in all axes and can be mounted directly on a vehicle  sled or other dynamic  testing device     Mounting Considerations   DTS suggests mounting the unit with the LEMO connector end facing away from  impact  The unit should be securely bolted to the vehicle  sled or other dynamic  testing device to provide the best shock protection and fa
2.    The EVENT input may be used in either of two ways     e In circular buffer mode  this input actually triggers data collection and is used  to mark zero time  T 0    e In recorder mode  this input is used to mark T 0 only     WARNING     Do not apply external voltages to the EVENT input     this could  result in damage to the unit  A simple FET switch can be used  to convert a voltage input to an appropriate contact closure   Please contact DTS if you need assistance     Using Your TDAS PLUS Visual Status Indicator with other  TDAS Equipment    Your TDAS PLUS Visual Status Indicator can be used with TDAS PRO racks  TDAS G5  Docking Stations  TDAS PLUS Mini Distributors  TDAS PLUS Distributors and the TDAS  PLUS Crashworthy Battery  Both power and control signals are supported by the fully   featured TDAS PLUS Distributor  If used with a TDAS PRO rack  TDAS G5 Docking  Station or TDAS PLUS Mini Distributor  the TDAS PLUS VSI will require a separate  power source  e g   a power only TDAS PLUS Distributor or TDAS PLUS Crashworthy  Battery         support  dtsweb com 7 Rev  2    TDAS PLUS Visual Status Indicator User   s Manual June 2005    TDAS PRO Racks and TDAS G5 Docking Stations  Control signals to and from the TDAS PLUS VSI to racks or docking stations require a  control cable  SIR xx xxxx   This cable is typically provided with your unit     e Using a control cable  connect the 7 pin LEMO connector to the CONTROL port  on the TDAS PLUS Visual Status Indicator  Connect th
3.  e g   TDAS PLUS Crashworthy Battery   or 2   connecting the unit to a TDAS PLUS Distributor  The cable appropriate for your appli   cation is typically provided with your unit     Power up and Power down Procedures   Whenever sufficient power is applied to the 12V PWR connector on the TDAS PLUS VSI   the unit will power up  Whenever power is removed from the unit  it will power down   Power up and power down is immediate upon application or removal of the power  source  A brief   1 second  power down power up cycle is sufficient to reinitialize the  unit     Communication Features    The CONTROL connector on the TDAS PLUS Visual Status Indicator allows access to  status and event signals to and from other TDAS equipment   See Appendix A for  connector specifics and pin assignments   It does not support direct PC communica   tions     Communication Method   The TDAS PLUS VSI  communicates  via its large red and green LED arrays  When  powered up  the RED status light will come on when the unit is receiving a control  signal from any TDAS equipment that is turned on     1  For circular buffer data collection mode  the RED status light will go dark and the  GREEN status light will come on when the system is armed  The system is now  waiting for a T20 event signal  If there is an event signal or a fault  the GREEN  status light will go dark and the RED status light will come on    2  For recorder data collection mode  the RED status light will go dark and the  GREEN status light
4.  html to find the phone number appropriate for your    region of the world        support dtsweb com 3 Rev  2    TDAS PLUS Visual Status Indicator User   s Manual June 2005    Introducing the  TDAS PLUS Visual Status Indicator    The TDAS PLUS Visual Status Indicator  VSI  provides the crash test engineer the  ability to visually verify TDAS system status from a distance  In an environment where  the test equipment may be a substantial distance away from the control room or in  another remote location  confirmation from the system that it is armed and healthy  prior to testing can be critical to testing success     This manual discusses the features available with the TDAS PLUS Visual Status  Indicator  To identify the specific hardware included with your system  please see your  packing list     Overview of TDAS PLUS Visual Status Indicator Features    Built and tested for 100  G dynamic testing environments    Highly visible from 360 degrees and 1000 feet    Maintenance free  long life red and green LED arrays    Uses standard DTS LEMO interfaces and control signals    Use with any TDAS PRO rack  TDAS G5 Docking Station  TDAS PLUS Mini   Distributor or fully featured TDAS PLUS Distributor    e Operates on 12 VDC power  nominal   including the power only TDAS PLUS  Distributor and TDAS PLUS Crashworthy Battery    e Integral mounting flanges     Connector Panel  The connector panel on the TDAS PLUS VSI allows you to connect external power and  control signals                 
5.  will come on when the system is armed and receives a start  record signal  The system is now collecting data and waiting for a T 0 event  signal  If there is an event signal or a fault  the GREEN status light will go dark  and the RED status light will come on     There is no condition in which both the RED and GREEN status lights will be on  simultaneously     Please pay close attention to the condition of the status lights during a test  A GREEN  status light indicates that the TDAS system is functioning properly and testing can       support dtsweb com 6 Rev  2    TDAS PLUS Visual Status Indicator User   s Manual June 2005    proceed  If the GREEN status light goes dark unexpectedly and the RED status light  comes on  the test should be aborted if this can be done in a safe manner     WARNING     If the GREEN status light on the TDAS PLUS Visual Status  Indicator goes dark unexpectedly during the performance of a  test  the test should be aborted if this can be done in a safe  manner     Using the Event Input    TDAS PLUS Visual Status Indicator contains a direct  pass through  contact closure  EVENT input to other TDAS equipment   See Appendix A for connector specifics and  pin assignments   This input provides a way to use a closure switch in harsh or noisy  environments  without negatively affecting the data acquisition system  A software  trigger can also be used   please see your TDAS Control software manual for informa   tion on how to set a software level trigger  
6. DDTS    909 Electric Ave   Suite 206  Seal Beach  CA 90740 USA  Phone   1 562 493 0158  Fax   1 562 493 3158  www dtsweb com    TDAS PLUS  Visual Status Indicator  User   s Manual    fe    4  Of    Sy    lt j         Geld    7          June 2005  Rev  2    TDAS PLUS Visual Status Indicator User   s Manual June 2005    Table of Contents    DTS SuppDOTt     iooriissseu xri xa Uer xREERRRkaERRERE x cutee EERERUVENEERERERE ERR EnaEERUKEEFERREUME EEEURK KE 3  Introducing the TDAS PLUS Visual Status Indicator                                         4  Overview of TDAS PLUS Visual Status Indicator Features                                 4  Connector Parigi saerdeoczeta tara teste evr rela ated educ vetu ined du tance sese eret b Eee 4  Basic Care and Handling  eise rere a uxUE s veErPESECRESRS iua REEF EERUNEERN EE RREEUN SEU REN RET 5  SHOCK Ratllidseecosnad feces tas fecusvaM o Dee a Ke oie etul aa tu ux TROVO VUE CTUM ee eens Te UNT 5  Mounting Consideratibs  us qi p Ex ERES aE NER RRUERERAAM ea beeen EE 5  Thermal Considerabloris    vq iux e tr eterne ird udi iaiaaeaia dao dus 5  Power Management 2    ccccceecceee cece eeeeee eee eens ence uuu eR eee ee 5  External Power PRrovViSlONS sesiecaccanvedaciecsincenssensenceeisiasciaeewidonsnecisiecieds TEAC 6  Power up and Power down Procedures        ccccesecseseesseeesseeeuseeseeeteeeetsaseesaetegaeneags 6  Communication Features             c essnacuvasuxuusavunFRRUNRRRREERERRRRRRRENARRREENFRRFERU NER NER MUR 6  COMMUNICATION  MET
7. NOG sine wees sun ix e auus el exe eov ex ed e Pod x e d e d e e Re 6  Using the Event INDUC iiio reis uiioucaocda 3  E50 sa VERRE UE IRES EERSESSNRYU  RNPESEUSSEXEREESRRTREERES 7  Using Your TDAS PLUS Visual Status Indicator with other TDAS Equipment    7  TDAS PRO Racks and TDAS G5 Docking Stations                   eeeseennn ne 8  TDAS PLUS Mini Distributor and TDAS PLUS Distributor                  eseeeeeeeeeeeee 8  TDAS PLUS  Crashwortliy Battery neu txt rego cd RU IECUR Ra E CUR ER E RECO 8  Appendix A  Connector Information                         cese eese essen nennen nnn nnn 9  Suggested Connector SOUECGS       ooh rites e Osa Le up ed uae strade eui Lead d e wie s 10  Appendix B  Mechanical Specifications                          e eee eese eese nnne nnn nnn nnn 11       support dtsweb com ii Rev  2    TDAS PLUS Visual Status Indicator User   s Manual June 2005    DTS Support    TDAS systems are designed to be reliable and simple to operate  Should you need  assistance  DTS has support engineers worldwide with extensive product knowledge  and crash test experience to help via telephone  e mail or on site visits     The best way to contact a DTS support engineer is to e mail Support dtsweb com   Your e mail is immediately forwarded to all DTS support engineers worldwide and is  typically the fastest way to get a response  particularly if you need assistance outside  of normal business hours  For assistance by telephone  please go to    http   www dtsweb com support
8. cilitate proper grounding   Mounting methods and mounting bolt selection should be carefully calculated so as to  withstand expected shock loading   See Appendix B for the unit   s mechanical specifi   cations      Thermal Considerations   It is extremely unlikely that excessive heating will ever be an issue in real world  testing applications using the TDAS PLUS VSI  Should you have any questions about  its use in your environment  please contact DTS     Power Management    A good power source is of paramount importance  Each TDAS PLUS Visual Status  Indicator should be powered from a fully charged 12 volt battery or a high quality  power supply with a nominal output voltage of 12 volts  10 16 volt range  and a  capacity of at least 1 amp  When assessing power requirements  please consider any  voltage drops that may occur due to cables  connectors  power converters  etc        support dtsweb com 5 Rev  2    TDAS PLUS Visual Status Indicator User   s Manual June 2005    Current draw for the TDAS PLUS VSI is negligible when connected to TDAS equipment  that is not turned on  The maximum current draw increases to less than 1 amp once  the TDAS equipment is turned on     External Power Provisions   The TDAS PLUS VSI does not contain any internal power source but has a dedicated  connector for primary input power   See Appendix A for connector specifics and pin  assignments   The voltage required to power the unit can be supplied in two ways  1   directly from a 12 volt battery 
9. e 19 pin LEMO connector  to either COM port on the rack or docking station     You will need to power the TDAS PLUS VSI from an external 12 volt power source   The cable appropriate for your configuration is typically provided with your unit     TDAS PLUS Mini Distributor and TDAS PLUS Distributor   Control signals to and from the TDAS PLUS VSI to a TDAS PLUS Mini Distributor or  fully featured TDAS PLUS Distributor require a control cable  SID xx xxxx   This cable  is typically provided with your unit     e Using a control cable  connect either end to the CONTROL port on the TDAS  PLUS Visual Status Indicator  Connect the other end to the CONTROL port on  the TDAS PLUS Mini Distributor or TDAS PLUS Distributor     With the appropriate cable  you can use the TDAS PLUS Distributor  fully featured or  power only  to power the TDAS PLUS VSI  Depending on your configuration  this cable  may be provided with your unit     e Using a power cable  connect either end to the 12V PWR input on the TDAS  PLUS Visual Status Indicator  Connect the other end to any available 10 16 volt  POWER OUT port on the TDAS PLUS Distributor     If you are using a TDAS PLUS Mini Distributor  you will need to power the TDAS PLUS  VSI from an external 12 volt power source  The cable appropriate for your  configuration is typically provided with your unit     TDAS PLUS Crashworthy Battery   With the appropriate cable  you can use the TDAS PLUS Crashworthy Battery to power  the TDAS PLUS VSI  Depending on y
10. our configuration  this cable may be provided with  your unit     e Using a power cable  connect either end to the 12V PWR input on the TDAS  PLUS Visual Status Indicator  Connect the other end to any available port on  the TDAS PLUS Crashworthy Battery     To enable control signals  you will need to connect the TDAS PLUS VSI to other TDAS  equipment with the appropriate support  TDAS PRO rack  TDAS G5 Docking Station   etc    The cable appropriate for your configuration is typically provided with your unit        support dtsweb com 8 Rev  2    TDAS PLUS Visual Status Indicator User   s Manual    Appendix A  Connector Information    4 pin 12V PWR connector   EGG 2B 304 CLL      panel view     Suggested cable connector P N   FGG 2B 304 CLADxx      Power     Fin        3 pin EVENT connector   EGG 1B 303 CLL      panel view     Suggested cable connector P N   FGG 1B 303 CLADxx      Event         Event       No connection       June 2005    7 pin CONTROL connector   EGG 2B 307 CLL         panel view     Suggested cable connector P N   FGG 2B 307 CLADxx    No connection       No connection       No connection       Common       Status        TDAS event bus                TDAS event bus        also used to sense TDAS system activity          support dtsweb com    Rev  2    TDAS PLUS Visual Status Indicator User   s Manual June 2005    Suggested Connector Sources   DTS uses LEMO connectors on the TDAS PLUS Visual Status Indicator  If you need to  purchase connectors  we suggest firs
11. t going to LEMO directly  http   www lemo com   index html   Their web site and worldwide sales team are very helpful  Should you  have difficulty obtaining a specific part number  they can suggest connector variations  or alternates and explain options that may be useful for your particular application   Another U S  source is Alpine Electronics  www alpine electronics com  in San Jose   California  They are a stocking distributor for LEMO and LEMO compatible connectors           support dtsweb com 10 Rev  2    TDAS PLUS Visual Status Indicator User   s Manual June 2005    Appendix B  Mechanical Specifications  Weight  1248 grams    12 375 inches 314 33 mm          11 375 inches 288 93 mm    ww 6 88 S9uput S E  ww    g 90T seupul 6T v    0 25 inches diam 6 35 mm diam    Height  6 06 inches 154 mm       support dtsweb com 11 Rev  2    
    